presented by - osisoft direct data transfer from me 2 pi system •data transfer running on the me...
TRANSCRIPT
![Page 1: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/1.jpg)
![Page 2: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/2.jpg)
2
Presented by
High Speed Data Collection with FactoryTalk® Historian ME
Enbridge Pipeline
Rockwell Automation
![Page 3: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/3.jpg)
3
What is a PI Server? … How big ??
What if it is small enough to fit in your hand?
![Page 4: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/4.jpg)
4
Agenda
• Introduction
• Data collection at Enbridge Pipeline
• Benefits of this new technology
• Future and Next steps
• Product roadmap
![Page 5: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/5.jpg)
5
• Industrial Automation
• Headquarters in Milwaukee, Wisconsin
• Serving manufacturing customers in 80+ countries -- emerging markets over 20% of total sales
Leading global provider of
industrial power, control
and information solutions
![Page 6: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/6.jpg)
6
• New Embedded Historian Module for ControlLogix
• Capability for high-speed data collection in the backplane
![Page 7: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/7.jpg)
7 © Copyright 2011 OSIsoft, LLC.
![Page 8: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/8.jpg)
8 © Copyright 2011 OSIsoft, LLC.
HIGH SPEED DATA COLLECTION
MORE ROBUST DATA COLLECTION
REMOTE AND OFF-LINE DATA COLLECTON
AND
LOW COST OF OWNERSHIP
![Page 9: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/9.jpg)
9
![Page 10: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/10.jpg)
10
![Page 11: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/11.jpg)
11
![Page 12: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/12.jpg)
12
Where traditional data collection is
done through interfaces and data servers
![Page 13: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/13.jpg)
13
Where traditional data collection is
done through interfaces and data servers
Data Transfer – transfers archive
data directly from the ME
module to Plant Historian
![Page 14: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/14.jpg)
14
Remote
![Page 15: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/15.jpg)
15
When connection is down, the module will store data and forward
the data once the connection is back up.
Remote
![Page 16: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/16.jpg)
16
When connection is down, the module will store data and forward
the data once the connection is back up.
Remote
![Page 17: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/17.jpg)
17
Enbridge U.S.
• U.S. Liquids Pipeline System
• Engineering in Superior
• Pump Stations spread across 9 states
• Remote Control via WAN/Scada System
![Page 18: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/18.jpg)
18
![Page 19: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/19.jpg)
19
Challenge – Multiple Data Sources
• Information in various locations throughout the Control System
– Large amount of info in local PLC only.
– On site chart recorder
– Local HMI alarm log
– Remote PI Server
![Page 20: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/20.jpg)
20
Challenge – Multiple Versions of the Story
• Local HMI alarms/status at 1 second scan rate
• Local Hi-Speed Chart Recorder
• Remote PI Server subject to SCADA System and WAN scan rate limitations
![Page 21: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/21.jpg)
21
Challenge – Incomplete Data
• Partial History
– Remote PI Server subject to network/power outages
– SCADA system includes only a subset of available data: that which is important to Control Center Operations.
![Page 22: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/22.jpg)
22
Challenge – Limited Access to Information
• Limited Access
– PLC info requires Engineering to access
– Chart recorder data requires Engineering to convert and interpret
– Local HMI requires Engineering to provide data
– Remote PI Server has limited access
![Page 23: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/23.jpg)
23
Challenge – More info & faster updates
• Complete history from PLC – Temps, Amps, Volts, Vibration, Gas Levels… things
not important to control center
– No gaps in history due to network/power outages
– One-second scan rates for more granular data
– Station configuration information for Engineering to interrogate and run reports
![Page 24: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/24.jpg)
24
Control Systems Engineer • Configuration • Diagnostics • Status / History
Maintenance Manager • Running hours • Vibration History • RTD Temperatures
Field Technicians • Status • Diagnostics • Historical Data
CCO Engineer • Hi-Resolution
Density/Viscosity • Temperature • Hi Speed Pressures
Engineering
Operations
Control Center
Maintenance
Challenge – Multiple Users of Information Production Manager
• Flow Rate • Pressure • Kilowatts
Production
![Page 25: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/25.jpg)
25
Solution – Distributed Historian (ME)
• PLC Chassis based FactoryTalk Historian ME
• Collect data in real-time at it’s birthplace
• Store and forward to Server w/o loss of history due to outages or scan rate
• Simple configuration – up in < 1 hour
• Solid state, no OS, patches,
![Page 26: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/26.jpg)
26
Solution – Distributed Historian (PI System)
• New PI Server for central access and long term storage
• Historian ME data pushed to the PI Server periodically.
• Scalable storage, horsepower, connectivity.
• Virtual Machine environment
![Page 27: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/27.jpg)
27
When connection is down, the module will store data and forward
the data once the connection is back up.
![Page 28: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/28.jpg)
28
Solution – Unified Access to Information
• Thin Client Platform integrates and provides the data thru a web based reporting and trending tool.
• Data remains distributed, collected in real-time
• Hundreds of data points available thru web browser
![Page 29: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/29.jpg)
29
Thin Client Web Server
PI Server
Web Based Clients
Historian ME Modules
Network Equipment SNMP Data Direct PLC Polling
![Page 30: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/30.jpg)
30
Project Status
• New PI Server running since November.
• 45ea. Historian ME Modules installed, configured, collecting data.
• Another 20+ installed but not yet configured
• Thin Client Server running since January.
![Page 31: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/31.jpg)
31
Project Roadmap
• 120+ ME Modules by end of 2011
• Assist other Enbridge entity in implementing this Historian solution, 25 more ME modules.
• Tuning Exception/Compression settings to find a balance of performance and resolution
![Page 32: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/32.jpg)
32
Next Steps…
• Build out Asset model for all stations.
• Evaluate need for multiple servers based on performance
• Migrate to Windows Server 2008 R2 64 bit
![Page 33: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/33.jpg)
33
Future Plans for Central PI Server?
• Evaluate SNMP connectivity for network equipment
• Evaluate Modbus TCP connectivity for substation relays
• Direct PLC polling for misc. installations
![Page 34: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/34.jpg)
34
Realized Benefits so far…
• Better representation of operating conditions due to a faster rate of data collection
• Station configuration data previously held in the PLC only is now easily available
• Evaluated 3000hp Pump-Motor history of running temperature – no rebuild needed
![Page 35: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/35.jpg)
35
Lessons learned…
• The standardized PLC programs in the 135 stations made this project feasible.
• Interest in getting this historical info turned our 3-year project into a 1.5-year project.
• You get to know and test your IT staff.
![Page 36: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/36.jpg)
36
Back to FactoryTalk Historian …
![Page 37: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/37.jpg)
37
Module specifics • Backplane connectivity • 10 millisecond scan rates • 2500 events / second • High Speed Data collection
utilizes controller trend object
• Very fast • Very deterministic data
collection
• One (1) and Two (2) GB memory sizes
• Store from hours to years – Worst case: 4 or 14 hours
(1GB vs 2GB) – OEM use case for one year
• Most customer applications will need: – Plant Historian for
long term storage
![Page 38: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/38.jpg)
38
Fully Operational Browser Functionality for Intuitive & Familiar User Experience
• Forward/back navigation is fully functional
• Establish favorites for quick access to critical information
• Add important displays to Links Bar
• Use Tabs to organize displays in a browser window
• Collaborate with co-workers using active hyperlinks
• Access previously viewed displays using History
![Page 39: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/39.jpg)
39
Easy Install and Deployment • Module is put in empty slot
in chassis • After boot up – it is instantly
live and accessible. • Context specific
configuration screens that are easy to understand and easy to use
• Module communicates over backplane, and able to identify controllers and data in the local chassis, thru “Auto Discovery”
![Page 40: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/40.jpg)
40
Backplane connectivity is not OPC
• Quick configuration thru Auto Discovery
• Backplane collection speeds down to 10 msec.
• Deterministic collection rates – 50msec is 50msec.
![Page 41: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/41.jpg)
41
Simple Reporting and Trending
• Tabular report to list values collected for a tag
• Trending of multiple tags in an easy to navigate dialog
![Page 42: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/42.jpg)
42
Direct data transfer from ME 2 PI System
• Data Transfer running on the ME module – Not PI to PI Interface – Configures the Tags on PI Server
directly • Tag name • Tag configuration
– Compression, scan rate etc.
– Checks and validates licenses before configuration
– Transfers data directly from ME archive to PI Server snapshot.
– No infrastructure in between!
Directory Server Client ServerPI Server
HQ
HistMEHistME HistME
Plant / Site C
![Page 43: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/43.jpg)
43
Full PI Server with PI Client access • All Traditional
Historian clients work with FactoryTalk Historian ME – PI DataLink – PI ProcessBook – PI WebParts – Other PI SDK clients
![Page 44: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/44.jpg)
44 © Copyright 2011 OSIsoft, LLC.
Controlling data collection with PLC • Add-On Profile (AOP) • Included with the module • Installed in RSLogix 5000 • Gives access to about 15 inputs
and 4 outputs • Can be used to alarm on
unexpected behavior • Data Transfer not running etc. • Can be used to control the access
to start a batch • If data runs out before the batch is
done – don’t start!
The AOP can also be used to control part of the Historian module
– Start and Stop Data collection • (set the Historian in “Idle” mode)
– Start and Stop Data Transfer • (Control network band width etc.)
![Page 45: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/45.jpg)
45
Conclusion • Embedded Historian • Automatic roll-up to Plant Historian • Allow for PI System clients to connect • PI DataLink, PI ProcessBook, etc. • Include calculations • Performance equations and totalizers
Historian in your hand !!
![Page 46: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/46.jpg)
46
For more information
http://discover.rockwellautomation.com/Historian
Jan Pingel
Product Manager, FactoryTalk Historian
+1 414 382-0364
Don Lindsey Enbridge Energy Company, Inc.
Senior Engineering
Technologist Enbridge (US), Inc.
Operator of the Enbridge
and Vector Pipeline Systems
+1 715 394-1509
[email protected] Superior, Wisconsin
![Page 47: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/47.jpg)
47
![Page 48: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/48.jpg)
48
Questions
Don Lindsey
Jan Pingel
![Page 49: Presented by - OSIsoft Direct data transfer from ME 2 PI System •Data Transfer running on the ME module –Not PI to PI Interface –Configures the Tags on PI Server directly •](https://reader034.vdocuments.net/reader034/viewer/2022052309/5b0c37287f8b9af65e8ba88b/html5/thumbnails/49.jpg)
Thank you