pressure area care - talley group ltd...weight (kg) 12.5 6.6 10.5 8.6 23.4 6.8 5.5 11.9 11.9 14.0...

3
...closer to the patient Pressure Area Care Product Range Features and Technical Data ...we help reduce avoidable harms

Upload: others

Post on 09-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Pressure Area Care - Talley Group Ltd...Weight (kg) 12.5 6.6 10.5 8.6 23.4 6.8 5.5 11.9 11.9 14.0 11.0 1.9 / 3.9 1.1 1.3 1.0 Mattress / Cushion Materials PU Air Cells l l l l l l l

...closer to the patient

Pressure Area CareProduct Range Features

and Technical Data...we help reduce avoidable harms

Page 2: Pressure Area Care - Talley Group Ltd...Weight (kg) 12.5 6.6 10.5 8.6 23.4 6.8 5.5 11.9 11.9 14.0 11.0 1.9 / 3.9 1.1 1.3 1.0 Mattress / Cushion Materials PU Air Cells l l l l l l l

Air Mattresses AirOverlays

Hybrid Mattresses

(Foam + Air)

Foam Mattresses Cushions

ProductFeature

QU

ATTR

O® A

cute

QU

ATTR

Paed

iatri

c

QU

ATTR

O® P

lus

PULS

AIR

™ C

hoic

e M

attre

ss

QU

ATTR

Sent

inel

QU

ATTR

Ove

rlay

PULS

AIR

™ C

hoic

e O

verla

y

FUSI

ON

™ H

ybrid

FUSI

ON

Res

pons

e

POLY

FLO

AT™

Su

prem

a

POLY

FLO

AT™

D

orm

ira

ATTI

VO™

+

B.A.

S.E.

™ S

eque

ntia

l C

ushi

on /

Rec

liner

Mat

FUSI

ON

™ H

ybrid

PULS

AIR

™ C

hoic

e

POLY

FLO

AT™

C

ushi

on

Ther

apy

Mod

e Active Therapy

1-in-4 cell type l l l l l l l

1-in-2 cell type l l l l

Reactive Therapy l l l l l l l l l l l

Cycle Duration (Minutes)

Variable (10-30)

Variable (10-30) 16 16 16 16 8 8 16 8 8

Air C

ell

Feat

ures

DEEP CELL THERAPY l l

TISSUEgard l l l l

Ortho-differential Support (ODS) l l l l l l l

Pow

er U

nit F

eatu

res

/Fu

nctio

ns

AUTOsupport l l l l l l l l l l l

Continuous Low Pressure l l l l l

Maximum Inflation l l l l l

Comfort Control l l l l l l l l l l l

PHASE FLOW l l l l l l l l l l l

Cov

er F

eatu

res

/Fu

nctio

ns

Multi-stretch l l l l l l l l l l l l l l l

Moisture Vapour Permeable l l l l l l l l l l l l l l l

Welded Cover Seams l l l l l l l l l l l l l l l

Machine Washable Cover l l l l l l l l l l l l l l l

Mat

tress

Fea

ture

sLow Air Loss l l l l l l l

Machine Washable Mattress l l l l

CPR l l l l l l l l

Transport Facility l l l l l l l

Cable Management l l l l l

Mis

c.

Active Seat Cushion Available l l l l l

Modular Construction l l l l l l l l l l l

Pressure Area Careproduct range features

Pressure Area Careproduct range features

ACTIVE THERAPY

Active support surfaces periodically redistribute the pressure beneath the body and are recommended by the EPUAP / NPUAP for a wide range of patients who cannot be regularly repositioned.

REACTIVE THERAPY

Reactive therapy enhances patient immersion and envelopment into the mattress and applies a constant low pressure to the skin and subcutaneous tissue.

The

rap

y M

od

e

The

rap

y M

od

e

ACTIVE 1-IN-4 CELL CYCLE

An active 1-in-4 cell cycle supports 75% of the patient’s body at all times, on groups of three inflated cells, whilst the fourth cell deflates sufficiently to

redistribute the pressure and encourage tissue reperfusion. Additional benefits include enhanced patient comfort, less awareness of support surface movement and a reduction of stimulus-related complications such as muscle spasm.

The

rap

y M

od

e

DEEP CELL THERAPYTM

DEEP CELL THERAPY allows the cells of the QUATTRO Acute to run at

lower internal pressures. This minimises the pressure applied to the patient’s skin and subcutaneous tissues during the cycle.

TISSUEGARDTM

TISSUEgard enables the partial immersion and envelopment of the patient into the support surface, reducing the

pressure on the patient’s skin and decreasing the pressure differential between inflated and deflated cells, which helps reduce tissue strain and associated shearing forces.

Air

Cel

l Fea

ture

s

Air

Cel

l Fea

ture

s

ORTHO-DIFFERENTIAL SUPPORTTM

ODS results in firmer outer edges of the mattress which facilitate patient

transfers and provide extra support, safety and comfort for larger or heavier patients. It also creates a softer central area of the mattress, ideal for smaller, lighter patients.

Air

Cel

l Fea

ture

s

AUTOSUPPORTTM

AUTOsupport automatically adjusts pressure within each of the cells throughout the cycle so that support,

posture and therapy are constantly maintained at optimum levels, in response to patient weight, movement and position. Equalisation of cell pressure automatically takes place at each stage of the cycle, again to ensure precise pressure and therapy is applied.

CONTINUOUS LOW PRESSURE

When in Continuous Low Pressure mode pressure is equalised within the cells to create a reactive therapy surface,

allowing greater immersion and envelopment into the mattress and optimum pressure distribution.

Po

wer

Uni

t F

eatu

res

Po

wer

Uni

t F

eatu

res

MAXIMUM INFLATION

Inflates the mattress to maximum static pressure for 15 minutes before returning to previous therapy mode, necessary for some nursing procedures when an active support surface is unsuitable.

Po

wer

Uni

t F

eatu

res

COMFORT CONTROL

Allows the carer to adjust the comfort setting in either therapy mode to help patient compliance.

PHASE FLOWTM

PHASE FLOW pressure control pump operates on demand only,

reducing power consumption, noise and extending service life.

Po

wer

Uni

t F

eatu

res

Po

wer

Uni

t F

eatu

res

MULTI-STRETCH

The multi-stretch cover promotes tissue offloading during cell deflation and reduces shear and friction during patient movement or manual repositioning. The material is waterproof, moisture-vapour permaeable and all seams are welded to protect the inside of the mattress from fluid ingress.

Co

ver

Fea

ture

s

Energy-efficient

MODULAR CONSTRUCTION

Simple to repair/service on site for minimum downtime.

Mis

c.

REACTIVE THERAPY(pressure reducing)

ACTIVE THERAPY(pressure relieving)

1-IN-4

REACTIVE THERAPY(pressure reducing)

ACTIVE THERAPY(pressure relieving)

LOW AIR-LOSS

Air is released and circulated beneath the mattress

cover to reduce humidity and help manage the skin 'microclimate' between the patient and the support surface.

Mat

tres

s F

eatu

res

Page 3: Pressure Area Care - Talley Group Ltd...Weight (kg) 12.5 6.6 10.5 8.6 23.4 6.8 5.5 11.9 11.9 14.0 11.0 1.9 / 3.9 1.1 1.3 1.0 Mattress / Cushion Materials PU Air Cells l l l l l l l

Dimensions / Materials

Air Mattresses Air Overlays

Hybrid Mattresses

(Foam + Air)

Foam Mattresses Cushions

QU

ATTR

O® A

cute

QU

ATTR

Paed

iatri

c

QU

ATTR

O® P

lus

PULS

AIR

™ C

hoic

e M

attre

ss

QU

ATTR

Sent

inel

QU

ATTR

Ove

rlay

PULS

AIR

™ C

hoic

e O

verla

y

FUSI

ON

™ H

ybrid

FUSI

ON

Res

pons

e

POLY

FLO

AT™

Su

prem

a

POLY

FLO

AT™

D

orm

ira

ATTI

VO™

+

B.A.

S.E.

™ S

eque

ntia

l C

ushi

on /

Rec

liner

Mat

FUSI

ON

™ H

ybrid

PULS

AIR

™ C

hoic

e

POLY

FLO

AT™

C

ushi

on

Pow

er U

nit D

imen

sion

s Length (mm) 355 355 355 355 355 355 355 355 210 355 355

Height (mm) 233 233 233 233 233 233 233 233 105 233 233

Depth (mm) 165 165 165 165 165 165 165 165 205 165 165

Weight (kg) 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 2.2 3.4 3.4

Mat

tress

/ C

ushi

on

Dim

ensi

ons

Length (mm) 1980 1300 1950 1950 2000 1930 1930 1970 1970 1980 1980 430 / 1080 430 430 430

Width (mm) 900 650 880 880 1200 850 850 880 880 880 880 430 430 430 430

Depth (mm) 240 180 180 180 180 130 130 170 170 150 150 70 65 40 76

Weight (kg) 12.5 6.6 10.5 8.6 23.4 6.8 5.5 11.9 11.9 14.0 11.0 1.9 / 3.9 1.1 1.3 1.0

Mat

tress

/ C

ushi

on

Mat

eria

ls

PU Air Cells l l l l l l l l l l l l

Foam l l l l l l l l

PU Coated Stretch Nylon

Coverl l l l l l l l l l l l l l l

Mis

c.

Number of Air Cells 27 20 30 30 17 17 17 18 18 48 /

120 7 8

Maximum user weight (kg) 250 95 200 200 370 160 127 250 250 250 250 127 150 102 160

Minimum User Weight None None None None None None None None None None None None None None None

Talley manufacture products to comply with National and International safety standards and are certified to ISO9001, ISO13485 and Directive 93/42/EEC. Every care has been taken to ensure that the information contained in this brochure was correct at the time of going to press. However, Talley reserve the right to modify the specification of any product without prior notice in line with a policy of continual product development. Our standard terms and conditions apply. © Talley Group Limited 2016. All rights reserved.

02/2

017

SIN C E 1953

GRE

AT

BRITI

SH D

ESIGN AND MANUFAC

TURIN

G

Talley Group LimitedPremier Way, Abbey Park Industrial EstateRomsey, Hampshire, SO51 9DQ England

TEL: +44(0)1794 503500FAX: +44(0)1794 503555

EMAIL: [email protected]

QUATTRO Acute, QUATTRO Plus, QUATTRO Sentinel, QUATTRO Overlay, PULSAIR Choice, FUSION Hybrid, FUSION Response, POLYFLOAT Suprema, POLYFLOAT Dormira, ATTIVO, B.A.S.E. Sequential and B.A.S.E. Recliner Mat are Registered Trade Marks of Talley Group Limited

Visco-elastic

Pressure Area Careproduct range technical data

Visco-elastic

860mm with-out bolsters

Bolsters and base