pressure reducing valve - vektek

3
www.vektek.com 800-992-0236 © Vektek, January 2019 Pressure Reducing Valve n Control pressure to individual devices. n For use in double or single acting systems. n Direct acting, poppet style, adjustable, cartridge construction. n Cartridge may be installed directly into your manifold. n Model 70-5410-10 set the pressure range from 750 to 4500 psi. Repeatability ± 7% n Model 70-5410-01 set the pressure range from 150 to 900 psi. Repeatability ± 10% n Maximum inlet pressure 5,000 psi. n Pressure Reducing Cartridge is interchangeable with the Pressure Limiting Cartridge in the same mounting cavity. n Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir. n Recommended Filtration: 25 Micron (NOM) /40 Micron (ABS) (minimum). For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µ in. R a surface finish. Pressure Reducing Valve Model No. Inlet Pressure* Set Pressure Range Repeatability A Manifold Mount Valve Assembly 70-5410-10 5000 psi 750 to 4500 psi ± 7% 5.8 70-5410-01 < 3000 psi 150 to 900 psi ± 10% 6.5 >3000 psi 300 to 900 psi *Maximum Inlet Pressure for PRV is 5,000 psi NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo ® special function valves, unless noted. Excess flow voids warranty. The graph shows the repeat range based on set pressure ILS705406 REV D 70-5410-10 70-5437-70 70-5410-01 70-5437-71 0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000 Repeat Pressure Range (PSI) Set Pressure (PSI) The graphs show the pressure drop through a PRV and manifold mount block ILS705405 REV E 0 250 500 750 1000 0 0.5 1 1.5 Pressure Differential (PSI) Flow (gpm) Pressure Drop vs Flow Operation: The Pressure Reducing Valve (PRV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure, the valve closes blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point. M-13 Accessory Valves Pressure Reducing Valve

Upload: others

Post on 16-Mar-2022

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Pressure Reducing Valve - Vektek

www.vektek.com 800-992-0236 © Vektek, January 2019

Pressure Reducing Valven Control pressure to individual devices.n For use in double or single acting systems.n Direct acting, poppet style, adjustable, cartridge construction.n Cartridge may be installed di rectly into your manifold.n Model 70-5410-10 set the pressure range from 750 to 4500 psi. Repeatability ± 7%n Model 70-5410-01 set the pressure range from 150 to 900 psi. Repeatability ± 10%n Maximum inlet pressure 5,000 psi.n Pressure Reducing Cartridge is interchangeable with the Pressure Limiting Cartridge

in the same mounting cavity.n Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage)

back to system reservoir.n Recommended Filtration: 25 Mi cron (NOM) /40 Micron (ABS) (mini mum).

For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µ in. Ra surface finish.

Pressure Reducing ValveModelNo.

InletPressure*

Set Pressure Range Repeatability A

Manifold Mount Valve Assembly70-5410-10 5000 psi 750 to 4500 psi ± 7% 5.8

70-5410-01< 3000 psi 150 to 900 psi

± 10% 6.5>3000 psi 300 to 900 psi

*Maximum Inlet Pressure for PRV is 5,000 psi

NOTE: Maximum system flow rate is 1.5 gpm(346.5 cu. in. per minute) for all

VektorFlo® special function valves, unless noted.

Excess flow voids warranty.

The graph shows the repeat range based on set pressure

ILS705406 REV D

� 70-5410-10 70-5437-70

� 70-5410-01 70-5437-71

0

1000

2000

3000

4000

5000

0 1000 2000 3000 4000 5000

Rep

eat P

ress

ure

Ran

ge (P

SI)

Set Pressure (PSI)

The graphs show the pressure drop through a PRV and manifold mount block

ILS705405 REV E

0

250

500

750

1000

0 0.5 1 1.5

Pre

ssur

e D

iffer

entia

l (P

SI)

Flow (gpm)

Pressure Drop vs Flow

Operation: The Pressure Reducing Valve (PRV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure, the valve closes blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point.

M-13

Accessory Valves

Pressure Reducing Valve

Page 2: Pressure Reducing Valve - Vektek

© Vektek, January 2019 800-992-0236 www.vektek.com

PRV Control BlocksnControl pressure independently on both the clamp and unclamp side of the fixture regardless of pump pressure setting. nEliminate the wait for full system pressure to finish cycling workholding components.nFor use in double or single acting systems. nDO3 Mounting, use on pump stack or as a remote mounted valve.nRecommended Filtration: 25 Mi cron (NOM) / 40 Micron (ABS) (mini mum).

Single PRV Control BlockModelNo.

InletPressure*

Set Pressure Range Repeat A

Manifold Mount Valve Assembly70-8425-51 5000 psi 750 to 4500 psi ± 7% 3.7

70-8425-52< 3000 psi 150 to 900 psi

± 10% 4.4>3000 psi 300 to 900 psi

*Maximum Inlet Pressure for PRV is 5,000 psi

Dual PRV Control BlockModelNo.

InletPressure*

Set Pressure Range Repeat A B

Manifold Mount Valve Assembly70-8425-50 5000 psi 750 to 4500 psi ± 7% 3.7 11.024

70-8425-53< 3000 psi 150 to 900 psi

± 10% 4.4 12.367>3000 psi 300 to 900 psi

*Maximum Inlet Pressure for PRV is 5,000 psi

NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo® special function valves, unless noted.

Excess flow voids warranty.

M-14

Accessory Valves

Pressure Reducing Control Block

Page 3: Pressure Reducing Valve - Vektek

www.vektek.com 800-992-0236 © Vektek, January 2019

Pressure Reducing CartridgeModel No.

Inlet Pressure*

Set Pressure Range Repeatability A B

70-5437-70 5000 psi 750 - 4500 psi ± 7% 5.0 3.25

70-5437-71 <3000 psi 150 - 900 psi ± 10% 5.7 3.96>3000 psi 300 - 900 psi

* Maximum Inlet Pressure for PRV is 5,000 psi

Pressure Limiting CartridgesModel No. Pressure Limit70-5430-08 Pressure Limit 750-250070-5430-07 Pressure Limit 1000-350070-5430-06 Pressure Limit 1500-5000

n Pressure Limiting Cartridge and Pressure Reducing Cartridge use the same mounting cavity.

ILS705406 REV D

� 70-5410-10 70-5437-70

� 70-5410-01 70-5437-71

0

1000

2000

3000

4000

5000

0 1000 2000 3000 4000 5000

Rep

eat P

ress

ure

Ran

ge (P

SI)

Set Pressure (PSI)

See product Page M-15

NOTE: For cavity tooling (multistep Reamer), order kit 62-7050-00.

If a PRV/PLV is no longer needed, use standard SAE#10 plug, 30-6011-99, to cap cavity for free fluid pass through.

30° .004 A .010 .0051.188 .010

30°±5°

-A-.626 .001

.563 .010

45°±15°

.002 A.945 .004

45°

.100±.005

.002 A

Minor Dia .812 .010 .854 .010-14 UNF .62 Min7/8

.770±.010

1.490±.010

1.335±.005

1.437±.010

R.03

ILS705402 REV E

.004 A

.203 .015 HighPressure Inlet .203 .015 Lower

Pressure Outlet

63

63

M-15

Accessory Valves

Pressure Limiting Cartridge and Pressure Reducing Cartridge Cavity