4
Featuring ACVMax Control with: l 439 Stainless Steel Fire Tube Heat Exchanger l ASME Stamped Heat Exchanger l 95% AFUE l Turndown ratios up to 5.5:1 l Low Pressure Drop with Proven Performance l 2” to 4” Venting l Multiple Venting Termination Options l Low NOx - 2012 SCAQMD Certified l 7 Models from 80 to 399 MBH l 2 Year Control & Blower Warranty l 10 Year Limited Heat Exchanger Warranty l 5 & 10 Year Extended Warranty Options High Efficiency Condensing Gas Boilers l 60 Second Set-up Based on Former TriMax Platform l Integrated Cascade Function for up to 6 Boilers l Two Reset Curves / Set Points l Multiple Zone Control l Multiple Circulator Control

Upload: others

Post on 01-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Prestige - Purchase Your HVAC Equipment Direct

Featuring ACVMax Control with:

l 439StainlessSteelFireTubeHeatExchangerl ASMEStampedHeatExchangerl 95%AFUEl Turndownratiosupto5.5:1l LowPressureDropwithProvenPerformancel 2”to4”Ventingl MultipleVentingTerminationOptionsl LowNOx-2012SCAQMDCertifiedl 7Modelsfrom80to399MBHl 2YearControl&BlowerWarrantyl 10YearLimitedHeatExchangerWarrantyl 5&10YearExtendedWarrantyOptions

High Efficiency Condensing Gas Boilers

l 60SecondSet-upBasedonFormerTriMaxPlatforml IntegratedCascadeFunctionforupto6Boilersl TwoResetCurves/SetPointsl MultipleZoneControll MultipleCirculatorControl

Prestige

Page 2: Prestige - Purchase Your HVAC Equipment Direct

Prestige - Leader in Ser viceabi l i ty

ACV-Max Control

60 Second Set-Up• Choosefrom6standardheatingapplicationsto setuptheboilerin60secondsorless. •FinnedTubeBaseboard •HighMassRadiant •CastIronBaseboard •LowMassRadiant •Radiators •Fancoil• Preconfiguredforindirecthotwaterapplications

Integrated CascadeJoinsupto6boilers:Masterboilerautomaticallyrecognizeslinkedboilers:MeetssimultaneousDHW&SpaceHeatingcalls:FullParallelModulation:AutomaticDutyCycling.

Multiple Zone Control• Accepts2spaceheatingcallswithindependentoutdoorresetcurves• Simultaneouslyheatdualtemperatureheatingsystemswithbuilt-inmixingvalvecontrol• Manageupto2spaceheatingzonesand1DHWzonewithoutanexternalzonecontrolpanel

Multiple Circulator Control• Presetsallowquickconfigurationof4circulatoroutputsfortheapplication• Eachcirculatoroutputisfullyconfigurableforcustomapplications

Intelligent TroubleshootingDescribeslockoutsinplainenglishandsuggestssolutions:Storeslast8errors.Recordssensorreadingsfor24hours.

Next Generation Fire Tube Heat ExchangerHigh Water Content •Providesstabletemperaturecontrol •Lowsensitivitytowaterflow •Reducesshortcycling •Adaptstolargeorsmallheatingloads

Unique Geometry •Designedformaximumreliabilitywithlowthermalstress •Improvedwaterflowformaximumheattransfer •439StainlessSteelwithtitaniumforcorrosionresistance •Polypropylenecondensatepanandflueresistscorrosion

Reliable Low Maintenance Design •Selfcleaningdesignwashesawaycombustiondebris •12yearhistoryofreliableperformance •Highperformanceburnerdesign •Lowpressuredropallowspipingdirectlytothesystem •ASMEStamped

Page 3: Prestige - Purchase Your HVAC Equipment Direct

Prestige - Leader in Contractor Fr iendly Features

Prestige Solo

Polypropylene Flue and Condensate PanEliminates corrosion from condensate

Test Ports in both Flue and Air Connections

Integrated Check Valve - To eliminateflue gas blow back in negative pressure locations

Offset Blower with quickconnect to minimize heatload and ease maintenance

Sound AttentuatedAir Inlet

ACVMax Display Module

Industry LeadingFire tube heatexchanger

Cast Aluminum burner plate withintegrated angled sight glass

Single piece gasket and insulation to reduceparts & ease maintenance

Swing Out Electrical Panel Permits quick access to boiler internals

The Widest Range of Venting and Termination Options

Venting-2”,3”,and4”diametersdependingonmodel-PVC,CPVC,SSandPolypropylenematerials-FlexiblePolypropyleneforchimneychases

-Concentric(399only)ortwinpipe-Extendedventlengthsupto100feet

-CommonVentformultipleboilers(399only)

Terminations-TraditionalPVC/CPVC/PP/SSpipingelbows

-Flush-mountPVCfortwinpipes-Flush-mountStainlessSteelfortwinpipes

-SingleholeConcentricTerminationfortwinpipes-HorizontalConcentricTermination(399only)

-HorizontalandVerticalCommonVentTerminations(399only)

Page 4: Prestige - Purchase Your HVAC Equipment Direct

p f

Blackwood NJ 08012One Triangle LaneTriangle Tube www.triangletube.com

856.228.3584856.228.8881

PrestigePerformance Specifications

Boiler Model Fuel

Input Modulation

MBHAFUE

DOEHeating Capacity

MBH

TurndownRatio

Net AHRIRating MBH

Water Volume

Gal.

Boiler Model

Supply/ReturnConnections

GasConnections

Vent/AirDiameter

DimensionsD x W x H

WeightLbs

95.1%* 7.4Solo 399 NaturalPropane

72.5 to 399 379,000 330,0005.5 : 1

4.5

Solo 299 NaturalPropane

72.5 to 299 272,000 237,00095% 7.4

Solo 250 NaturalPropane

43.6 to 240 218,000 190,00095% 5.5 : 1

4.1 : 1

4

Solo 175 NaturalPropane

30.9 to 170 154,000 134,00095% 5.3

Solo 155 NaturalPropane

27.8 to 153 138,000 120,00095% 5.5 : 1

5.5 : 1

2.1

Solo 110 NaturalPropane

20 to 110 99,000 86,00095% 2.1

Solo 80 NaturalPropane

16 to 80 72,000 63,00095% 5.0 : 1

5.5 : 1

103

Solo 110 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16" 103

Solo 80 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16"

118

Solo 175 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16" 128

Solo 155 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

140

Solo 299 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8" 210

Solo 250 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

216Solo 399 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8"

Connections/Dimensions/DataBoiler Model Fuel

Input Modulation

MBHAFUE

DOEHeating Capacity

MBH

TurndownRatio

Net AHRIRating MBH

Water Volume

Gal.

Boiler Model

Supply/ReturnConnections

GasConnections

Vent/AirDiameter

DimensionsD x W x H

WeightLbs

95.1%* 7.4Solo 399 NaturalPropane

72.5 to 399 379,000 330,0005.5 : 1

4.5

Solo 299 NaturalPropane

72.5 to 299 272,000 237,00095% 7.4

Solo 250 NaturalPropane

43.6 to 240 218,000 190,00095% 5.5 : 1

4.1 : 1

4

Solo 175 NaturalPropane

30.9 to 170 154,000 134,00095% 5.3

Solo 155 NaturalPropane

27.8 to 153 138,000 120,00095% 5.5 : 1

5.5 : 1

2.1

Solo 110 NaturalPropane

20 to 110 99,000 86,00095% 2.1

Solo 80 NaturalPropane

16 to 80 72,000 63,00095% 5.0 : 1

5.5 : 1

103

Solo 110 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16" 103

Solo 80 1" 1/2" 3" 17-5/16" x 19-3/4" x 36-9/16"

118

Solo 175 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16" 128

Solo 155 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

140

Solo 299 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8" 210

Solo 250 1-1/4" 3/4" 3" 17-5/16" x 19-3/4" x 36-9/16"

216Solo 399 1-1/2" 1" 4" 23-5/8" x 24-7/8" x 39-3/8"

Couple to Industry Leading Indirect Water Heater FamilyTank in Tank Design (No Coils – Maintenance Free)

l Unparalleledperformanceallows25-50%smallersizethancompetitorsl Fastestrecovery-recoveryin30%-40%lesstimethancompetitorsl StainlessSteelconstructionl ResidentialSmarttankshavelimitedlifetimewarrantyl ComfortTankshave10yearlimitedwarrantyl 7sizesinSmartfamilyl 2sizesinComfortfamily

Triangle Tube reserves the right to make product changes or improvements at any time without notice.

*Thermal Efficiency

2015

-15

Pre

stig

e S

olo

AC

VM

ax L

itera

ture

- 1

2/15

/15