ambiradsupport.ambirad.co.uk/manuals/ambirad price 2013_2014.pdfindustrial air curtains (airbloc)...
TRANSCRIPT
Price List 2013 - 2014Effective from September 2013. All prices are ex works. E&OE
..................................................................................................
..................................................................................................
AMBIRAD AIRBLOC NORDAIRNICHE BENSON A Thomas & Betts Company. Registered in England No. 1390934
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
New Products For 2013-14
New products included in the latest price
list for the 2013-14 include:
> ULTRA high efficiency condensing unit
heater with thermal efficiencies of
up to 108%. Available from October
2013
> Quartz Glow range of electric radiant
heating systems has been expanded
to include IP24 rated weatherproof
heaters in the form of the Sorrento
range, as well as Titan mobile units
> Commercial air curtains and ceiling
tile heaters now have a substantial
presence in this years price list with
a comprehensive overview of the
complete range
AMBIRAD AIRBLOC NORDAIRNICHE BENSON A Thomas & Betts Company. Registered in England No. 1390934
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
@HVACUK
New Look AmbiRad Website Coming SoonThe new site will provide a quicker, easier and more interactive experience - with all our market leading products available at a
touch of a button.
Designed to provide the ultimate user-friendly experience with improved navigation and functionality throughout, all vital
information is just one click from the homepage.
Keep Up-To-Date With Everything AmbiRad
Want to know the latest news from AmbiRad and HVAC in general then follow us on Twitter,
or alternatively sign up for the AmbiRad monthly e-zine at [email protected].
Radiant Heating ...........................................................................
...........................................................................
Warm Air...........................................................................
...........................................................................
Heating & Ventilation...........................................................................
...........................................................................
Air Curtains...........................................................................
...........................................................................
AMBIRAD
BENSON
AIRBLOC
NORDAIRNICHE
VSX
Vision
VSX & Vision
Nor-Ray-Vac
Sonning
RV
Quartz Glow
SmartCom
6-7
8-11
12-13
14-15
16
17
18-19
20
High Efficiency Condensing Unit Heaters
High Efficiency Unit Heaters
Gas Fired Unit Heaters
Unit Heater Flue
External / Rooftop Gas Fired Unit Heaters
Oil Fired Unit Heaters
Gas & Oil Fired Cabinet Heaters
External Gas & Oil Fired Cabinet Heaters
High Efficiency Cabinet Heaters
Indirect Gas Fired Heating & Ventilation Units
Marquee Heaters
Portable Blowers
Flue
Energy Saving Controller
Destratification Fans
22-23
24-25
26-27
28-29
30
31
32-33
34-37
38-39
40-41
42-44
45
45
46-48
49
50
50
ULTRA
UESA
UDSA / UDSB
Variante
Flue
External Variante
OUH
Cabinet Heaters
Cabinet Heaters
PV
SDH / SHH
MH
Air Blower
Flue
SmartCom
DS
Impellor
High Efficiency Radiant Tube Heating Systems
Radiant Tube Heating Systems
Vision Accessories
Continuous Radiant Tube Heating Systems
Recirculated Air Radiant Tube Heating Systems
Radiant Plaque Heaters
Electric Radiant Heaters
Energy Saving Controller
Direct Gas Fired Heating & Ventilation Units
Gas Fired Combined Heating & Ventilation
Evaporative Cooling System
52-53
54-55
56-57
58
DV / DH
DF / IDF
Air Rotation
ColdAIR
AC
AC Chassis
ACR
AC & ACR Mini
ACT
SmartElec
AB
62-64
65
66-67
68
69
70
71
72-73
Commercial Air Curtains
Commercial Ceiling Tile Heaters
Energy Saving Controller
Options
Industrial Air Curtains
.................................................................................................................................................................................................................................................................................................................
.............................................................................................................................................................................................................................................................................................................
...........................................................................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
.............................................................................................................................................
1
@HVACUK
ContactsDepartment Contacts Phone Number Email Address
Sales Manager Paul Fox 01384 489 700 [email protected]
Customer Services Manager Keith Sprague 01384 489 711 [email protected]
Customer Services Team Leader Teresa Griffiths 01384 489 721 [email protected]
Customer Services Team Amie Brickles 01384 489 715 [email protected]
Leanne Sidaway 01384 489 714 [email protected]
Sam Wallace 01384 489 712 [email protected]
Commercial Air Curtains (Airbloc) Adam Squire 01384 489 708 [email protected]
Product Manager (Nor-Ray-Vac) Nick Winton 07778 604 223 [email protected]
Key Account Manager Dave Garvey 07796 337 904 [email protected]
Industrial Air Curtains (Airbloc) John Halley 07979 243 147 [email protected]
Sales Admin & Export (Benson) Kim Powell 01547 521 144 [email protected]
Spares (AmbiRad) Lisa Powell 01384 489 734 [email protected]
Spares (Benson) Chezlynne Griffiths 01547 521 146 [email protected]
Sales Design Engineers Team Andrew Thompson 01384 489 718 [email protected]
Jamie Garratt 01384 489 722 [email protected]
Ryan Lancaster 01384 489 713 [email protected]
Sales Support Team (Nordair Niche) Dale Thomas 01384 489 733 [email protected]
Sam O'Flanagan 07967 656 005 [email protected]
Technical Manager (Nordair Niche) John Coe 07979 243 151 [email protected]
After Sales Technical Support Team Dave Guest 01384 489 200 [email protected]
Steve Hogg 01384 489 200 [email protected]
Service Manager Graham Fage 01384 489 732 [email protected]
Service Manager (Nordair Niche) Peter Mansfield 07970 719 965 [email protected]
Service Requests Julie Bennett 01384 489 795 [email protected]
Credit Control Sally Wassell 01384 489 754 [email protected]
Tel: 01384 489 700
Technical Support: 01384 489 200
Fax: 01384 489 707
Email: [email protected]
www.ambirad.co.uk2
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
Scotland
Tony Sullivan Mobile: 07771 804710 Home/Fax: 01506 890270
Email: [email protected]
North East and Cumbria
Geoff Stevenson Mobile: 07787 127955
Email: [email protected]
North West and West Yorkshire
Phil Lowe Mobile: 07979 242785 Home/Fax: 0161 681 5878
Email: [email protected]
East Midlands and South Yorkshire
Ian ReedMobile: 07867 671573
Email: [email protected]
West Midlands and Mid Wales
Steve Latimer Mobile: 07836 720345Home/Fax: 01785 824909
Email: [email protected]
South West and South Wales
Mark Ford Mobile: 07831 474428Home/Fax: 01425 461890
Email: [email protected]
South East and Home Counties
Sales OfficeMobile: 07810 756956Office: 01384 489700
Email: [email protected]
3
For Northern and Southern Ireland please contact the sales office on:
01384 489 700
3
AMBIRAD AIRBLOC NORDAIRNICHE BENSON AMBIRAD AIRBLOC NORDAIRNICHE BENSON
UK Sales Contacts
South and Home Counties
Marianne Sibborn (Product Manager)Mobile: 07884 117796Home: 01462 686397
Email: [email protected]
West Midlands and Wales
Chris Jones Mobile: 07901 515878Home/Fax: 01384 489717
Email: [email protected]
Scotland and Northern England
Jason FryerMobile: 07789 717811Home/Fax: 01977 600466
Email: [email protected]
Department Contacts Phone Number Email Address
Customer Services Manager Keith Sprague 01384 489 711 [email protected]
Airbloc Product Manager Marianne Sibborn 07884 117 796 [email protected]
Customer Services Team Leader Teresa Griffiths 01384 489 721 [email protected]
Commercial Air Curtains (Airbloc) Adam Squire 01384 489 708 [email protected]
Industrial Air Curtains (Airbloc) John Halley 07979 243 147 [email protected]
Spares Lisa Powell 01384 489 734 [email protected]
After Sales Technical Support Team Dave Guest 01384 489 200 [email protected]
Steve Hogg 01384 489 200 [email protected]
Service Manager Graham Fage 01384 489 732 [email protected]
Service Requests Julie Bennett 01384 489 795 [email protected]
Credit Control Sally Wassell 01384 489 754 [email protected]
4
AMBIRAD AIRBLOC NORDAIRNICHE BENSON
UK Sales Contacts
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
Radiant Heating VSX 6 - 7
Vision 8 - 11
VSX & Vision 12 - 13
Nor-Ray-Vac 14 - 15
Sonning 16
RV 17
Quartz Glow 18 - 19
SmartCom 20
..................................................................................................
..................................................................................................
AMBIRAD
5
High Efficiency Radiant Tube Heating Systems....................................................................................................................................................
....................................................................................................................................................
VSX
Features & BenefitsFeatures: New advanced burner technology
> Choice of burner ratings from 20 to 50kW
> NOx emissions as low as 52ppm on certain models - 40% lower than standard radiant heater
> All units CE approved
> New slim-line burner head provides
a long evenly distributed flame that dramatically improves temperature distribution along the entire length of the heater, delivering a more even floor coverage
> Combustion occurs entirely within the firing tube. Not only does this reduce the size and weight of the traditional burner control housing but it also helps to reduce noise levels (as quiet as 47 dB(A) 3m field)
> The inclusion of a recuperative heat exchanger on VSX models (patent P308150GB), mounted adjacent to the burner housing, significantly increases thermal efficiencies up to 90% and enhances radiant efficiency above 62.5%.
Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has yet again raised the industry standard in terms of innovation and technical performance.
The range of high efficiency Vision radiant tube heaters delivers exceptional performance in terms of efficiency and the potential to reduce energy costs.
The foundation of this development is a high efficiency advanced burner.
15% more effective than standard radiant tube heaters, with payback of 6 months achievable when redeeming ECA allowances.
Model Range > The high efficiency VSX range, with
recuperative heat exchanger, which is
available as a 'U' tube model only.
6
*Applicable to certain models only
....................................................................................................................................................
High efficiency radiant tube heating system ..................................................................................................
..................................................................................................
AMBIRAD
The Government’s Enhanced Capital
Allowance scheme actively encourages
industry and commerce to reduce energy
consumption by promoting the use of
energy efficient equipment. This symbol verifies that the product has been
independently assessed and qualifies for the
ECA scheme, an upfront tax relief enabling
businesses that invest in energy-saving
equipment to claim 100% first-year capital
allowances against their taxable profits.
Enhanced Capital Allowances
7
Vision VSX Heat Exchanger 'U' Tube Models (forced burner) Propane models not available
Model Heat Input kW Gas Rate m3/h Description Length mm List Price £
VSX20UTNCE 20.0 1.9 ‘U’ tube 4100 P.O.A
VSX25UTNCE 25.0 2.4 ‘U’ tube 4100 P.O.A
VSX30UTNCE 32.0 3.1 ‘U’ tube 4100 P.O.A
VSX35UTNCE 36.0 3.4 ‘U’ tube 5900 P.O.A
VSX40UTNCE 40.0 3.8 ‘U’ tube 5900 P.O.A
VSX45UTNCE 44.0 4.2 ‘U’ tube 5900 P.O.A
VSX50UTNCE 49.5 4.7 ‘U’ tube 7660 P.O.A
Turbulators
Stainless steel spiral turbulators optimise
tube temperatures by ‘scrubbing’ the flue
gases against the tube surface, maximising
heat transfer and increasing radiant efficiency.
Heat Exchanger
Mounted adjacent to the burner housing.
Significantly increases thermal efficiencies
up to 90% and enhances radiant efficiency
above 62.5%.
Burner
Burner ratings range between 20 and 50kW
in 5kW increments. The new burner head
located within the firing tube leg provides a
very long flame with even heat distribution.
NOx emissions are very low - as low as
52ppm on certain models.
Flueing
Units can be installed unflued or
individually flued (including concentric
flues to minimise building penetrations).
Fresh air intake
Fresh air can be ducted into the heat
exchanger from outside the building to
provide clean combustion air, required
when there are contaminates in the
atmosphere.
Radiant Tube Heating Systems....................................................................................................................................................
....................................................................................................................................................
Vision
Features & BenefitsFeatures: New advanced burner technology
> Choice of burner ratings from 15 to 100kW
> Combustion occurs entirely within the firing tube. Not only does this reduce the size and weight of the traditional burner control housing but it also helps to reduce noise levels (as quiet as 47 dB(A) 3m field)
> New slim-line burner head provides
a long evenly distributed flame that dramatically improves temperature distribution along the entire length of the heater, delivering a more even floor coverage
> All units CE approved
Benefits:Easy to install and maintain
> On forced gas burner models all electrical wiring is contained at one end of the product, which is particularly time saving when installing single linear (VSLF ) heater models
> All units require straightforward annual maintenance
The Vision range of radiant tube heaters delivers exceptional performance in terms of efficiency and the potential to reduce energy costs.
The foundation of this development is a high efficiency advanced burner.
Model RangeThere are two vision ranges:
> The VS range, complete with stainless
steel reflectors and endcaps, is
available in U tube, single linear
and double linear models and can
be mounted in linear or U tube
herringbone configurations
> The VSA range, complete with
aluminised reflector and end caps,
which is available in U tube, single
linear and double linear models and
can be mounted in linear or U tube
herringbone configurations
8
*Applicable to certain models only
VS/VSA 'U' tube
...............................................................................................
Optimum economy and fuel savings
> The elimination of both distribution
and standby losses coupled with high
operational efficiencies at the point of
use enable fuel savings of up to 65%
compared with conventional heating
systems
> Excellent radiant performance. More
of the available heat generated is
distributed to floor level thereby
improving efficiency and reducing
energy consumption
Additional control at the touch of a buttonAll models are compatible with AmbiRad
SmartCom control systems. SmartCom
units incorporate a host of features such as
self learning optimised start-up to ensure
increased comfort and energy savings.
SmartCom3
control panelRadiant black bulb sensor
(See page 20 for details)
Herringbone ConfigurationHerringbone systems are specifically designed to suit individual building requirements; they can incorporate up to ten 'U' tube or linear heaters on one exhaust manifold. The exhaust manifold may be terminated through the roof or wall.
The particular benefits of herringbone systems are:
> Optimised energy efficiencies
> All units share a common internal flue thereby raising efficiency within the building
> Uniform heat distribution within the space being heated
> Improved aesthetics and minimal risk of water ingress - only one penetration of the building is required to enable the products of combustion to be expelled
> Universal application - they are ideal for both new build and older premises (in particular where penetration of an asbestos roof is an issue)
> VSO UH Models are Listed on the Energy Technology List
VSLF/VSALF Single Linear (forced)
VSDL/VSADL Double Linear
9
Vision VSUT 'U' Tube Models (induced burner) For propane models replace 'N' in model description to a 'P'
Model Heat Input kW
Gas Rate m3/h
Description Adaptor Ref Length mm
VSA List Price £
VS List Price £Nat Gas LPG
VS(A)15UTNCE4 15.8 1.5 Compact ‘U’ tube 1 n/a 2219 930.00 977.00
VS(A)15UTNCE 15.0 1.4 ‘U’ tube 1 1 3417 806.00 846.00
VS(A)20UTNCE 19.5 1.9 ‘U’ tube 1 1 4142 892.00 937.00
VS(A)25UTNCE 23.5 2.3 ‘U’ tube 1 1 5066 977.00 1026.00
VS(A)30UTNCE 29.5 2.8 ‘U’ tube 1 1 6029 1066.00 1119.00
VS(A)35UTNCE 36.0 3.4 ‘U’ tube 1 4 5709 1167.00 1225.00
VS(A)40UTNCE 40.0 3.8 ‘U’ tube 1 4 5709 1211.00 1272.00
VS(A)45UTNCE 44.0 4.2 ‘U’ tube 4 4 7471 1269.00 1332.00
VS(A)50UTNCE 48.0 4.6 ‘U’ tube 4 4 7471 1327.00 1393.00
Vision VSLF Linear Models (forced burner) Propane models not available
Model Heat Input kW
Gas Rate m3/h
Description Adaptor Ref* Length mm
VSA List Price £
VS List Price £Nat Gas LPG
VS(A)15LFNCE6 13.8 1.3 Standard ‘SL’ tube 2 n/a 5984 806.00 846.00
VS(A)20LFNCE7 19.5 1.9 Standard ‘SL’ tube 2 n/a 6992 892.00 937.00
VS(A)25LFNCE8 23.5 2.3 Standard ‘SL’ tube 2 n/a 8022 977.00 1026.00
VS(A)30LFNCE10-5 29.5 2.8 Standard ‘SL’ tube 2 n/a 10662 1075.00 1129.00
VS(A)35LFNCE10-5 36.5 3.5 Standard ‘SL’ tube 3 n/a 10892 1167.00 1225.00
VS(A)40LFNCE13-5 40.0 3.8 Standard ‘SL’ tube 3 n/a 13492 1269.00 1332.00
VS(A)45LFNCE13-5 45.0 4.3 Standard ‘SL’ tube 3 n/a 13492 1284.00 1348.00
VS(A)50LFNCE13-5 50.0 4.8 Standard ‘SL’ tube 3 n/a 13492 1327.00 1393.00
VS(A)15LFNCE8 13.8 1.3 Extended ‘SL’ tube 2 n/a 8022 882.00 926.00
VS(A)20LFNCE10-5 19.5 1.9 Extended ‘SL’ tube 2 n/a 10662 1004.00 1054.00
VS(A)25LFNCE10-5 23.5 2.3 Extended ‘SL’ tube 2 n/a 10662 1066.00 1119.00
VS(A)30LFNCE12-5 29.5 2.8 Extended ‘SL’ tube 2 n/a 12652 1173.00 1232.00
VS(A)35LFNCE13-5 36.5 3.5 Extended ‘SL’ tube 3 n/a 13492 1211.00 1272.00
VS(A)40LFNCE16 40.0 3.8 Extended ‘SL’ tube 3 n/a 16092 1332.00 1399.00
VS(A)45LFNCE16 45.0 4.3 Extended ‘SL’ tube 3 n/a 16092 1380.00 1449.00
VS(A)50LFNCE16 50.0 4.8 Extended ‘SL’ tube 3 n/a 16092 1460.00 1533.00
Vision VSLI Linear Models (induced burner) For propane models replace 'N' in model description to a 'P'
Model Heat Input kW
Gas Rate m3/h
Description Adaptor Ref Length mm
VSA List Price £
VS List Price £Nat Gas LPG
VS(A)15LINCE6 15.0 1.4 Standard ‘SL’ tube 1 1 5984 806.00 846.00
VS(A)20LINCE7 19.5 1.9 Standard ‘SL’ tube 1 1 6992 892.00 937.00
VS(A)25LINCE8 23.5 2.3 Standard ‘SL’ tube 1 1 8022 977.00 1026.00
VS(A)30LINCE10-5 29.5 2.8 Standard ‘SL’ tube 1 1 10662 1075.00 1129.00
VS(A)35LINCE10-5 36.0 3.4 Standard ‘SL’ tube 1 1 10892 1167.00 1225.00
VS(A)40LINCE13-5 40.0 3.8 Standard ‘SL’ tube 1 1 13492 1269.00 1332.00
VS(A)45LINCE13-5 44.0 4.2 Standard ‘SL’ tube 1 4 13492 1284.00 1348.00
VS(A)50LINCE13-5 50.0 4.8 Standard ‘SL’ tube 4 4 13492 1327.00 1393.00
VS(A)15LINCE8 15.0 1.4 Extended ‘SL’ tube 1 1 8022 882.00 926.00
VS(A)20LINCE10-5 19.5 1.9 Extended ‘SL’ tube 1 1 10662 1004.00 1054.00
VS(A)25LINCE10-5 23.5 2.3 Extended ‘SL’ tube 1 1 10662 1066.00 1119.00
VS(A)30LINCE12-5 29.5 2.8 Extended ‘SL’ tube 1 1 12652 1173.00 1232.00
VS(A)35LINCE13-5 36.0 3.4 Extended ‘SL’ tube 1 1 13492 1211.00 1272.00
VS(A)40LINCE16 40.0 3.8 Extended ‘SL’ tube 1 1 16092 1332.00 1399.00
VS(A)45LINCE16 44.0 4.2 Extended ‘SL’ tube 1 4 16092 1380.00 1449.00
VS(A)50LINCE16 50.0 4.8 Extended ‘SL’ tube 1 4 16092 1460.00 1533.0010
..................................................................................................
..................................................................................................
AMBIRADRadiant tube heating system
Vision VSDL Double Linear Models (induced burner) For propane models replace 'N' in model description to a 'P'
Model Heat Input kW
Gas Rate m3/h
Description Adaptor Ref Length mm
VSA List Price £
VS List Price £Nat Gas LPG
VS(A)15DLNCE12 30.0 2.8 Standard ‘DL’ tube 4 4 11628 1693.00 1778.00
VS(A)20DLNCE14 39.0 3.8 Standard ‘DL’ tube 4 4 13644 1872.00 1966.00
VS(A)25DLNCE16 47.0 4.6 Standard ‘DL’ tube 4 4 15704 2054.00 2157.00
VS(A)30DLNCE21 59.0 5.6 Standard ‘DL’ tube 4 4 20904 2248.00 2360.00
VS(A)35DLNCE21 72.0 6.8 Standard ‘DL’ tube 4 4 21444 2453.00 2576.00
VS(A)40DLNCE27 80.0 7.6 Standard ‘DL’ tube 4 4 26644 2636.00 2768.00
VS(A)45DLNCE27 88.0 8.4 Standard ‘DL’ tube 5 5 26644 2686.00 2820.00
VS(A)50DLNCE27 100.0 9.6 Standard ‘DL’ tube 5 5 26644 2787.00 2926.00
VS(A)15DLNCE16 30.0 2.8 Extended ‘DL’ tube 4 4 15704 1846.00 1938.00
VS(A)20DLNCE21 39.0 3.8 Extended ‘DL’ tube 4 4 20904 2087.00 2191.00
VS(A)25DLNCE21 47.0 4.6 Extended ‘DL’ tube 4 4 20904 2239.00 2351.00
VS(A)30DLNCE25 59.0 5.6 Extended ‘DL’ tube 4 4 24964 2441.00 2563.00
VS(A)35DLNCE27 72.0 6.8 Extended ‘DL’ tube 4 4 26644 2542.00 2669.00
VS(A)40DLNCE32 80.0 7.6 Extended ‘DL’ tube 4 4 31842 2784.00 2923.00
VS(A)45DLNCE32 88.0 8.4 Extended ‘DL’ tube 5 5 31842 2887.00 3031.00
VS(A)50DLNCE32 100.0 9.6 Extended ‘DL’ tube 5 5 31842 3051.00 3204.00
Vision VSO 'U' Tube Models (induced burner) Model Heat Input
kWGas Rate
m3/hDescription Adaptor Ref Length
mm List Price £Nat Gas LPG
VSO15UTNCE 15.0 1.4 ‘U’ tube 1 1 4120 P.O.A
VSO20UTNCE 20.0 1.9 ‘U’ tube 1 1 4120 P.O.A
VSO25UTNCE 25.0 2.3 ‘U’ tube 1 1 4120 P.O.A
VSO30UTNCE 32.0 2.8 ‘U’ tube 1 1 5955 P.O.A
VSO35UTNCE1 36.0 3.4 ‘U’ tube 4 4 5955 P.O.A
VSO40UTNCE1 40.0 3.8 ‘U’ tube 4 4 5955 P.O.A
VSO45UTNCE 44.0 4.2 ‘U’ tube 4 4 7760 P.O.A
VSO50UTNCE 48.0 4.6 ‘U’ tube 4 4 7760 P.O.A
Vision Herringbone Combined Flue Heating System
VSO herringbone only
Herringbone systems are specifically designed to suit individual building requirements and can incorporate up to 10
'U' tube or linear heaters on one exhaust manifold. Please contact 01384 489700 for more information.£P.O.A
1 Not ECA listed
11
Radiant tube heating system ..................................................................................................
..................................................................................................
AMBIRAD
Vision Notes:* For unflued heater only, please add stainless steel unflued terminal. For models 15-30kW, part number 201866-SUB & for models 35-50kW, part number 201865-SUB
Vision AccessoriesRadiant Accessories
Part Number Description List Price £
6506 Gas valve (½’’ BSP) 13.00
6500 Flexible gas connector (½’’ BSP 600mm long) Plastic coated stainless steel with union to BS6501 Part 1. 1991 Class ‘‘C’’ construction
36.00
6500-2 Flexible gas connector (½’’ BSP 1000mm long for VS40LF and above) Plastic coated stainless steel with union to BS6501 Part 1. 1991 Class ‘‘C’’ construction
43.00
65156516
Suspension chain (Galvanised, 10m length)Suspension chain (Galvanised, 90m length)
23.50198.00
6524-SUB Speedlinks (8 per pack) 13.50
6518 ‘D’ Shackles (Galvanised, each) 1.50
C766300-SUB Turnbuckle assembly 6.50
6124 Run on timer (0-5 hours) 134.00
1350-31350-4
Undershield deflector 2438mm (c/w 2 munson rings per deflector)
Undershield with 3’’ munson rings (VS15-30)Undershield with 4’’ munson rings (VS35-50)
50.0050.00
Wall Mounting BracketsPart Number Brackets Per Heater Model List Price
Per Bracket £
Vision VS ‘U’ tube wall brackets
WMB-13-22-38 2 VS 15/20/25/30 19.90
WMB-13-22-38 4 VS 35/40 19.90
WMB-13-22-38 5 VS 45/50 19.90
Vision VSX ‘U’ tube wall brackets
WMB-13-22-38 3 VSX 20/25/30 19.90
WMB-13-22-38 4 VSX 35/40/45 19.90
WMB-13-22-38 5 VSX 50 19.90
Vision VS linear wall brackets
WMB-13-22-38 3 VS 15 6m 19.90
WMB-13-22-38 4 VS 15 8m 19.90
WMB-13-22-38 4 VS 20 7m 19.90
WMB-13-22-38 4 VS 25 8m 19.90
WMB-13-22-38 5 VS 20/25/30/35 10.5m 19.90
WMB-13-22-38 6 VS 30 12.5m 19.90
WMB-13-22-38 6 VS 35/40/45/50 13.5m 19.90
WMB-13-22-38 7 VS 40/45/50 16m 19.90
12
..................................................................................................
..................................................................................................
AMBIRADRadiant tube heating system
Protective Wire GuardPart Number Description Model List Price £
BG15UT4 ‘U’ tube VS 15UT4 62.20
BG15UT ‘U’ tube VS 15UT 77.50
BG20UT ‘U’ tube VS 20UT 101.00
BG25UT ‘U’ tube VS 25UT 125.00
BG30UT ‘U’ tube VS 30UT 182.00
BG35-40UT ‘U’ tube VS 35/40UT 182.00
BG45-50UT ‘U’ tube VS 45/50UT 237.00
BG3L6 Linear VS 15LF 6 105.00
BG3L7 Linear VS 20LF 7 124.00
BG3L8 Linear VS 15/25LF 8 144.00
BG3L10-5 Linear VS 20/25/30LF 10-5 189.00
BG3L12-5 Linear VS 30LF 12-5 240.00
BG4L10-5 Linear VS 35LF 10-5 189.00
BG4L13-5 Linear VS 35/40/45/50LF 13-5 259.00
BG4L16 Linear VS 40/45/50LF 16 282.00
M102005-SUB ‘U’ tube Vision Optima 2 module 20/25 128.00
M102015-SUB ‘U’ tube Vision Optima 3 module 30/35/40 205.00
TBA ‘U’ tube Vision Optima 4 module 45/50 283.00
6569 Black bulb sensor guard 30.60
Fresh Air Intake Kit & AdaptorsPart Number Description List Price £
VSI-DA VS/VLI Ducted air adaptor kit 22.40
VSF-DA VSLF/VSX Ducted air adaptor kit 22.40
FAFK-4 Fresh air intake kit(Compromising 3m x 100mm I.D aluminium tube (7070-SUB), 1 x rubberised flashing plate and fixing kit (7700H-1), 1 x 100mm dia. terminal (L101590-SUB)
122.00
Flue ConnectorsPart Number Adapter Ref Description List Price £
7177-SUB 1 125mm (5’’) Fan/flue connector for U tube and induced linear models 31.60
201881 2 125mm (5’’) Flue connector for forced linear models (15-30kW) 33.70
201882 3 125mm (5’’) Flue connector for forced linear models (35-50kW) 35.20
7176-SUB 4 125mm (5’’) Fan/flue connector for double linear models (15-40kW) 33.20
202365 5 125mm (5’’) Fan/flue connector for double linear models (45-50kW) 33.30
201889 6 125mm (5’’) VSX Heat exchanger flue connector 36.70
Twin Wall Flue ComponentsPart Number Description List Price £
7156 Straight flue 914mm long 47.90
7157 Straight flue 1524mm long 73.40
7158 Adjustable straight flue 450mm long 36.70
7700H-1 Rubberised roof plate complete with fixing kit 43.00
7162 Gas vent terminal/cowl 37.70
7166 Elbow adjustable 0-90o 34.70
Twin Wall Flue KitsPart Number Description List Price £
TWFK-5A Kit ‘A’ - 1 X 1524mm length tube (7157), 1 x 914mm length tube (7156), 1 x 450mm adjustable length flue (7158), rubberised roof plate and fixing kit (7700H-1 and terminal (7162)
240.00
TWFK-5B Kit ‘B’ as Kit ‘A’ plus 2 adjustable elbows (7166) 309.00
13
Radiant tube heating system ..................................................................................................
..................................................................................................
AMBIRAD
9
Nor-Ray-Vac Continuous Radiant Tube Heating System
A continuous radiant tube system incorporating multiple burners in a series, designed to suit individual requirements. Please contact 01384 489700 for more information.
£P.O.A
Continuous Radiant Tube Heating Systems....................................................................................................................................................
....................................................................................................................................................
Features & BenefitsFeatures:
> Reduces overall costs, with savings of up to 60% being achieved over conventional heating systems
> In-line fuel efficient burners with inputs ranging from 12 to 46kW
> Common vacuum fan operation
> Stoichiometric or ‘perfect’ combustion
> 91% combustion efficiency
> Rapid heat-up times
> Good aesthetic integration with building
> Minimal vent penetrations
> Capable of running three 46kW burners in a radiant branch
> Widest range of burner inputs for any continuous system
> Uniform distribution of heat
> Reliability and safety of operation to the latest European standard for multi- burner systems (EN 777)
> Qualifies for inclusion on the Government’s Energy Technology List.
Nor-Ray-Vac is a gas fired continuous radiant tube heating system, designed specially for the building it is required to heat. The following criteria form the basis of each particular system design:
> Heat loss of the building for the required thermal environment
> Local climate conditions
> Type of activity in the building
> Specific architectural features relating to the structure
The Nor-Ray-Vac system is designed to
provide uniform heat coverage over the
entire floor area. Alternatively, the system
can also cater for distinct zones providing
a varied degree of comfort level within the
overall layout of the building.
AmbiRad strives to become part of the
‘design team’, working closely with
engineers or end users to determine the
specific design parameters for the
Nor-Ray-Vac scheme layout. This contact
between the company’s engineers and the
system designer or client will give the most
effective Nor-Ray-Vac system.
The result is a heating system designed
specifically for the needs of the building and
the way that the premises are managed.
Model RangeThe Nor-Ray-Vac Series continuous radiant tube heating system includes six natural gas or propane burner models from 12 to 46kW, radiant tube lengths from 5.2 to 27 metres. Maximum tube temperatures range from 450°C to 480°C.
Nor-Ray-Vac
14
Continuous radiant tube heating system ..................................................................................................
..................................................................................................
AMBIRAD
....................................................................................................................................................
System OperationThe system operates on a vacuum principle and utilises a zero governor within a dedicated gas valve ensuring optimum efficiency, reliability
and safety.
The zero governor will only allow flow of gas when a vacuum is created by the fan. Therefore as well as the standard failsafe (where the gas
valve locks out with ignition or gas supply failure), the zero governor also mechanically prevents gas flow in the event of vacuum shut down.
The control of gas flow through the zero governor and the air flow into the mixing chamber while under the influence of the vacuum fan,
enables stoichiometric combustion at the burner head.
Stoichiometric combustion permits the inclusion of further burners within the same tubing ‘downstream’ from the first burner, ensuring evenly
distributed heat along the length of radiant tube.
Conforming to the European Gas Appliance regulations (EN 777), the end vent module burner has been developed to ‘prove’ flow of air at the
start of each radiant branch. The end vent module burner is a unique feature to the Nor-Ray-Vac system and instils the principle of ‘safety of
operation’ as a prerequisite of design.
15
Sonning is a high-level radiant tube heating system using hot air as the heating medium, rather than hot water, steam or the combustion products from a naked flame. The system is particularly suitable for heating large factories and aircraft hangers.
With Sonning radiant tube heating, there are no moving parts to maintain at high level, routine maintenance of other systems causes disruption to personnel and high level access to the equipment may be impeded by congested and restricted floors.
High temperature air circulates around
a closed circuit of spiral loops in
configurations of 2-6 tubes, providing a
powerful source of radiant heat to the room
or space being warmed and ensuring a
totally safe environment.
No air is discharged into the space - it is
returned to the heater, then reheated to
a pre-determined supply temperature and
recirculated around the system by a high
temperature centrifugal fan.
Since the heat source is completely
independent of the recirculating air stream,
any gas or liquid fuel can be burnt within
the Sonning heater combustion chamber.
Model RangeThe heaters will operate equally as
effectively on a wide variety of fuels, natural
gas/LPG/Oil. If required, Sonning heaters
can be fitted with dual fuel burners giving
the user the option to use either gas or oil.
Heater ratings are offered from 50kW to
500kW.
Sonning heaters are of vertical configuration
facilitating the use of contra-flow heat
exchanger and combustion chamber.
This allows for low air resistance, low air
pressure and the optimum in heat transfer
efficiency.
Sonning Recirculated Air Radiant Tube Heating Systems
Hot air radiant tube heating
system, fired by natural
gas, LPG or oil, designed
to suit individual building
requirements.
Please contact 01384 489700 for more information.
£P.O.A
Recirculated Air Radiant Tube Heating Systems....................................................................................................................................................
....................................................................................................................................................
Sonning
16
The RV Series represents todays most popular line of gas-fired, infra-red plaque heaters.
This unvented heater is ideal for use in many applications including areas of high air filtration, high ceilings and spot heating.
The RV Series offers exclusive design features, a proven history and a variety of kW and control options.
Features & Benefits > Ceramic burner provides maximum
infrared radiation
> Stainless steel rods increase heat
temperature and efficiency
> Highly polished aluminium reflector
design
> Direct spark ignition
> Compact design reduces installation
costs
> CE Certified
Model Range
RV plaque heaters are available in five sizes,
with heat inputs ranging from 8.8kW to
46.9kW.
Applications > Churches
> Factories
> Sports Halls
> Warehouses
> Workshops
Radiant Plaque Heaters....................................................................................................................................................
....................................................................................................................................................
RV
Model Heat Input kW Description List Price £
RV 30 8.8 Plaque heater 669.00
RV 60 17.6 Plaque heater 805.00
RV 90 26.4 Plaque heater 944.00
RV 130 38.0 Plaque heater 1099.00
RV 160 46.9 Plaque heater 1317.00
RV Gas Fired Radiant Plaque Heaters
17
Electric Radiant Heaters....................................................................................................................................................
....................................................................................................................................................
Quartz GlowThe AmbiRad Quartz Glow range provide instant high frequency infra-red heat, which is focused exactly where required.
Quartz Glow incorporate the latest shortwave heating technology, giving energy efficient ways to heat people indoors or outside.
Model RangeThere are three Quartz Glow ranges:
> The Apollo range of indoor heaters
designed to suit all industrial and
commercial situations and heat
requirements
> The Sorrento range is a robust
weatherproof heater
> The Titan range, ideal for emergency
or 'spot' heating. Comes in static or
mobile versions
Model Heat Input kW
Description Dimensions Minimum mounting height (m)
List Price £
QH 15-1 1.5 Single tube 420 x 225 x 115
2.1 276.00
QH 30-1 3.0 Double tube 420 x 390 x 115
3.0 485.00
QH 45-1 4.5 Triple tube 420 x 525 x 115
3.5 626.00
QH 45-3 4.5 Triple tube - 3ph 420 x 525 x 115
3.5 672.00
QHL 30-1 3.0 Double linear tube
855 x 255 x 115
3.0 511.00
QHL 45-1 4.5 Triple linear tube 1280 x 225 x 115
3.5 708.00
QHL 45-3 4.5 Triple linear tube - 3ph
1280 x 255 x 115
3.5 739.00
QHL 90-3 9.0 Triple double linear tube - 3ph
855 x 632 x 115
5.0 1240.00
Apollo
The AmbiRad Apollo range of indoor heaters, manufactured from
extruded aluminium, offers a choice of power options 1.5kW -
9kW to suit all situations and requirements. They are adjustable
both vertically and horizontally for accurate heat placement.
Safety guards are available where required.
The Apollo range is ideal for:
> Churches
> Factories
> Farming and horticulture
> Garages and workshops
18
Model Heat Input kW
Description Dimensions Minimum mounting height (m)
List Price £
SOR 15 1.5 Single tube 430 x 228 x 323
2 268.00
SORDL 30 3.0 Double linear tube
815 x 228 x 323
2.5 - 4.0 460.00
SORTL 45 4.5 Triple linear tube
1202 x 228 x 323
2.5 - 4.0 660.00
Sorrento
The AmbiRad Sorrento range is a robust weatherproof heater
(IP24 rated). The range is a premium versatile heater that is
also available in a double or triple option and can be grouped
together horizontally and vertically making it suitable for countless
applications.
The Sorrento range is ideal for:
> Churches
> Horticulture
> Garages
> Restaurants and bars
> Workshops
........................................................................................................................................................
Model Heat Input kW
Description Dimensions List Price £
TI-STAT 3.0 Static heater 650 x 430 x 200 516.00
TI-MOB 3.0 Mobile heater 1140 x 650 x 650 688.00
........................................................................................................................................................
Titan
The AmbiRad Titan range offers efficient and reliable emergency
or 'spot' heating. Both the mobile and static versions of the Titan
are fitted with an anti-tilt device to prevent misuse or accidents
on site. The Titan mobile also has lockable front wheels, further
enhancing it's safety.
The Titan range is ideal for:
> Building and construction
> Emergency heating
> Garages and workshops
> Paint curing
> Paint and plaster drying
Electric radiant heating ..................................................................................................
..................................................................................................
AMBIRAD
19
Energy Saving Controller....................................................................................................................................................
....................................................................................................................................................
SmartComEnvironmental issues dictate that buildings need to operate as effectively and efficiently as possible.
AmbiRad has introduced SmartCom3, the intelligent energy management controller, in order tosatisfy the growing need for higher efficiencies and to complement the development of efficient heating systems.
Simple to program and operate, SmartCom3 provides cost-effective energy management for small single heater installations through to large multi-zone applications requiring centralised control.
Features and Benefits > Easy to program multi-key entry and
on screen prompts
> Suitable for controlling heating and/
or cooling
> Reduced installation time – units can
be networked via screened cable
> Integral warm air temperature sensor
> Optional remote air sensor, remote
black bulb sensor, duct sensor or outdoor sensor
> Alphanumeric backlit display with
angled screen for easy viewing
> Remote burner lock out facility
> Easy-set overtime and holiday periods
> Hours run metering and service data logging
> Compact IP30 enclosure complete with top or bottom cable entry
> Security – optional passwords prevent unauthorised access to unit
> Dual temperature settings for sports/
non- sports comfort heating
SmartCom Energy Saving ControllerPart number Description List Price £
B-SC3-SZA SmartCom single zone controllerStandard functions include single stage heating/cooling, self adapting optimised start, volt free BMS override, clock enabled relay, additional modes or operation, frost protection and night setback, lockout modes additional external inputs and optimum start
232.00
B-SC3-MZA SmartCom multi-zone controllerAll the functions as 'single zone controller' plus, the ability to communicate with other SmartCom3 controllers, thereby enabling centralised control of multiple zones.
325.00
29-01-222 SmartCom black bulb sensor 51.00
FunctionsSuitable for use with both standard radiant tube and warm air heaters together
with ducted installations. > Self adapting optimised start
> Volt free remote on/off
> Single stage heating/cooling
> Ability to communicate with up to 15 slave units which may be centrally controlled by one master control
(SmartCom3 multi-zone only)
> High / low heat two stage heating (warm
air only)
> Three stage cooling or ventilation
> Fully modulating heating and cooling
> Clock update, temperature functions and
program settings
> Zonal lock out indication and reset
functions
> Multi-zone or split zone (radiant applications)20
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
Warm AirULTRA 22 - 23
UESA 24 - 25
UDSA / UDSB 26 - 27
Variante 28 - 29
Flue 30
External Variante 31
OUH 32 - 33
Cabinet Heaters 34 - 37
External Cabinet Heaters 38 - 39
PV 40 - 41
SDH / SHH 42 - 44
MH 45
Air Blower 45
Flue 46 - 48
SmartCom 49
DS 50
Impellor 50
..................................................................................................
..................................................................................................
..................................................................................................
..................................................................................................
BENSON
21
AmbiRad continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the new ultra high efficient ULTRA series of energy saving condensing gas fired unit heaters.
The ULTRA range provides the highest efficiency levels and substantially reduced CO2 & NOx emissions (under 25ppm).
The units exceed the requirements of
current Building Regulations L2, with
thermal efficiencies up to 108% to provide
exceptional levels of seasonal efficiency.
Also the extremely low NOX emissions
enable BREEAM points to claimed (when
applicable).
These 4th generation units utilise tubular
primary heat exchanger and a secondary
condensing heat exchanger with an
aerodynamic profile and 4-pass flue gas
circuit.
Model Range
> The ULTRA condensing units are
available in five models with heat
outputs ranging from 25kW to 94kW
(five models) for use on natural gas or
propane
> For use on natural gas (G20, G25) or
propane (G31)
Features & BenefitsFeatures
> Thermal efficiency of 100% at full load
and up to 108% at minimum load for
lower operational costs up to 108%
thermal efficiency
> Substantially reduced CO2 and NOx
emissions (under 25 ppm) considerably
lower than the emissions of the
previous generation of unit heaters,
and already exceeding European
standards
> Reduced energy bills
> Ideal for new low carbon buildings
> Up to 35% energy saving on
replacement heaters
> Burner with new “pull through”
combustion technology. Negative
pressure ensures that no gas or flue
gas can escape into the heated space
> Versatile flue options (top or rear
connections) for ease of installation
> High flow axial fan for a powerful air
throw, decreases stratification and
improves heat distribution
> 5:1 turn down ratio for close
temperature control. Reduced
temperature gradients help prevent
stratification
High Efficiency Condensing Unit Heaters....................................................................................................................................................
....................................................................................................................................................
ULTRA
22
> Available from October 2013
Air Distribution
A high capacity axial flow fan is fitted to all units for improved air
throws and reduced stratification.
An optional economy thermostat may be fitted to heaters installed
at high level to recirculate warm air down to working level when the
burner is switched off.
23
High efficiency condensing unit heaters ..................................................................................................
..................................................................................................
BENSON
ULTRA Condensing Gas Fired Unit Heaters Propane models availableModel Nominal Heat
Output kWAirflow m3/h
Flue Dia Ø mm
Standard Unit List Price £
ULSA 025 25.0 3590 80 P.O.A
ULSA 035 32.6 3878 80 P.O.A
ULSA 050 49.7 6076 80 P.O.A
ULSA 075 69.5 8408 100 P.O.A
ULSA 100 94.3 10617 100 P.O.A
Condensate Drain
All units are supplied complete with
condensate traps (loose) and condensate
drain points to the heater and the flue.
Burner
Advanced burner technology utilises a
single self-aligning burner, with multi-try
ignition for optimum reliability and ease of
maintenance.
Secondary Heat Exchanger
Manufactured using high quality corrosion
resistant materials, the non-welded design
of the heat exchanger reduces thermal
stress for enhanced life expectancy.
Primary Heat Exchanger
Manufactured from high quality corrosion resistant
steel, the entirely new primary heat exchanger
reduces thermal stress for enhanced life expectancy.
These 3rd generation units utilise corrosion resistant aluminium in the manufacture of the MacroChannel multipass heat exchanger and are up to 25% lighter than the previous condensing units.
UESA units are fully condensing heaters with thermal efficiencies of up to 103.7%.
Model RangeThe UESA fully condensing heaters have a
high capacity axial flow fan and outlet
louvres for freeblowing applications. Models
are available with heat outputs from 35 to
102kW.
Applications
> Factories
> Retail Outlets
> Showrooms
> Sports Arenas
> Warehouses
> Workshops
Features > Additional aluminium Macrochannel
heat exchanger provides fully
condensing operation throughout the
full firing range
> Reduced CO2 and Nox emissions
> Up to 30% energy saving on
replacement heaters
Features & Benefits > Reduced CO2 and NOx emissions
> Reduced energy bills
> Ideal for new low carbon buildings
> Up to 30% energy saving on
replacement heaters
> Versatile flue options for ease of siting
> Unique streamlined aerodynamic
profile of the heat exchanger results
in minimal resistance to airflow to
give longer throws, improved air
distribution and reduced temperature
gradients to minimise energy
consumption further
> Manufactured using high quality
corrosion resistant materials, the non-
welded design of the heat exchanger
reduces thermal stress for enhanced
life expectancy
> Advanced burner technology utilises
a single self-aligning burner, with
multi-try ignition for optimum
reliability and ease of maintenance
High Efficiency Condensing Unit Heaters....................................................................................................................................................
....................................................................................................................................................
UESA
24
UESA Condensing Gas Fired Unit Heaters Propane models availableModel Nominal Heat
Output kWAirflow m3/h
Flue Dia Ø mm
List Price £
UESA 35 34.9 3900 100 P.O.A
UESA 55 54.4 6100 100 P.O.A
UESA 83 82.2 9060 130 P.O.A
UESA 102 101.2 10570 130 P.O.A
UESA Optional EquipmentDescription UESA 35
List Price £UESA 55
List Price £UESA 83
List Price £ UESA 102List Price £
BurnerTwo stage (high/low) burner Modulating control
167.00419.00
167.00419.00
167.00419.00
167.00419.00
Air outlet dischargeVertical louvres30o downturn nozzle60o downturn nozzle
69.4066.30
132.00
71.4071.40
143.00
76.5086.70
173.00
76.5086.70
173.00
ThermostatAir re-circulating thermostat 71.00 71.00 71.00 71.00
ControlsSmartCom single zone control panel c/w int.sensorSmartCom multi zone control panel c/w int. sensorRemote room sensor (for use with SmartCom)
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
Sundries¾’’ BSP gas valve¾’’ BSP flexible connection
15.0043.00
15.0043.00
15.0043.00
15.0043.00
For flue options please see page 30
25
High efficiency condensing unit heaters..................................................................................................
..................................................................................................
BENSON
The Government’s Enhanced Capital
Allowance scheme actively encourages
industry and commerce to reduce energy
consumption by promoting the use of
energy efficient equipment. The high
thermal efficiency of UESA units (up to
104%), significantly exceeds the 91%
threshold for Enhanced Capital Allowances.
This symbol verifies that the product has
been independently assessed and qualifies
for the ECA scheme, an upfront tax relief
enabling businesses that invest in energy-
saving equipment to claim 100% first-year
capital allowances against their taxable
profits.
Enhanced Capital Allowances
UDSA and UDSB units are a technically advanced range of gas fired unit heaters designed to deliver outstanding energy performance and economy for reduced operating and life cycle costs.
The heat exchanger achieves 92% thermal efficiency reducing energy consumption and running costs.
Model RangeThe UDSA models have a high capacity axial
flow fan and horizontal outlet louvres for
freeblowing applications. Models available
with heat outputs from 11kW to 97kW.
UDSB models have a direct drive centrifugal
fan for ducted applications. Standard units
provide static pressures of 125 pascals and
are supplied with a duct outlet spigot.
Depending on model size the fan speed may
be changed on-site to provide increased
static pressure or increased air volumes to
suit the application.
For freeblowing UDSB applications optional
outlet louvres should be added at time
of order. Models are available with heat
outputs from 15kW to 64kW.
Applications
> Automotive workshops
> Factories
> Retail outlets
> Sports arenas and halls
> Warehouses
> Workshops
Features & BenefitsFeatures
> Unique streamlined aerodynamic
profile of the heat exchanger results in
minimal resistance to airflow to give
longer throws, improved temperature
distribution and reduced temperature
gradients to further minimise energy
consumption
> Standard units supplied with Titanium
stabilised heat exchangers
> Single self aligning burner complete
with multi-try ignition for optimum
reliability
> Advanced burner technology utilises a
single self-aligning burner, with multi-
try ignition for optimum reliability and
ease of maintenance
> Versatile flue options for ease of siting
High Efficiency Unit Heaters....................................................................................................................................................
....................................................................................................................................................
UDSA & UDSB
26
UDSA Axial Fan Unit HeatersStandard units: Titanium stabilised aluminised steel heat exchanger, c/w horizontal louvres or 4-way outlet for vertical discharge units. Suitable for natural gas (G20). For propane gas (G31) please specify at point of ordering and add £13 net.
Model Nominal Heat Output kW
Airflow m3/h
Flue Dia Ø mm
Horizontal Discharge Unit
List Price £
Vertical Discharge Unit
List Price £
UDSA 11 11.0 1020 80 1392.00 -
UDSA 15 14.6 1360 80 1452.00 1506.00
UDSA 20 18.3 1700 80 1491.00 -
UDSA 25 25.6 2385 100 1581.00 1634.00
UDSA 30 29.2 2725 100 1632.00 -
UDSA 35 34.9 3510 100 1777.00 1829.00
UDSA 43 42.1 4535 100 1857.00 1910.00
UDSA 50 48.6 5180 100 1905.00 1958.00
UDSA 55 54.7 5830 130 2077.00 2130.00
UDSA 64 64.4 6810 130 2180.00 2233.00
UDSA 73 73.0 7770 130 2472.00 2525.00
UDSA 85 85.1 9065 130 2717.00 2769.00
UDSA 100 97.0 10360 130 2949.00 3002.00
UDSA & UDSB Optional EquipmentDescription 11
List Price £15 / 20
List Price £25 / 30
List Price £ 35 / 43 / 50List Price £
55 / 64List Price £
73 / 85 / 100List Price £
BurnerTwo stage (high/low) burner Modulating control
167.00419.00
167.00419.00
167.00419.00
167.00419.00
167.00419.00
167.00419.00
Air outlet dischargeVertical louvres4 way louvres (vertical discharge only)Horizontal louvres (UDSB only)30o downturn nozzle60o downturn nozzle
54.60--
52.50104.00
54.6045.4025.5055.60
113.00
55.6055.6040.8064.30
128.00
69.4069.4029.6066.30
132.00
71.4074.5040.8071.40
143.00
76.5080.10
-86.70
173.00
ThermostatAir re-circulating thermostat 71.00 71.00 71.00 71.00 71.00 71.00
ControlsSmartCom single zone control panel c/w int.sensorSmartCom multi zone control panel c/w int. sensorRemote room sensor (for use with SmartCom)
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
Sundries½’’ BSP gas valve¾’’ BSP gas valve½’’ BSP flexible connection¾’’ BSP flexible connectionWall brackets (UDSA only)Drop rods M10 x 3 metre
13.00-
36.00-
72.406.60
13.00-
36.00-
72.406.60
13.00-
36.00-
72.406.60
-15.00
-43.00
126.006.60
-15.00
-43.00
126.006.60
-15.00
-43.00
126.006.60
UDSB Centrifugal Fan Unit HeatersStandard units: Titanium stabilised aluminised steel heat exchanger, duct outlet (louvres must be added for freeblowing applications). Suitable for natural gas (G20). For propane gas (G31) please specify at point of ordering and add £13 net. Adjustable fan speed allows a range of static pressures and airflows.
Model Nominal Heat Output kW
Flue Dia Ø mm
Horizontal Discharge Unit
List Price £
Vertical Discharge Unit
List Price £
UDSB 15 14.6 80 1650.00 1703.00
UDSB 20 18.3 80 1765.00 -
UDSB 25 25.6 100 1887.00 1945.00
UDSB 30 29.2 100 1922.00 -
UDSB 35 34.9 100 2204.00 2262.00
UDSB 43 42.1 100 2286.00 2344.00
UDSB 50 48.6 100 2351.00 2409.00
UDSB 55 54.7 130 2528.00 2591.00
UDSB 64 64.4 130 2629.00 2692.00
27
High efficiency unit heaters ..................................................................................................
..................................................................................................
BENSON
The compact highly efficient Variante heaters provide cost effective heating for most commercial and industrial buildings, such as showrooms, factories, workshops, warehouses, greenhouses etc.
Using wall or roof mountings, the heaters are available for either room sealed or conventional power flue applications.
Model RangeThe Variante gas fired units are available
with heat outputs ranging from 12kW-
144kW for use on natural gas (G20), or
propane (G31).
Air distributionVRA heaters are fitted with high efficiency
axial fans and discharge warm air through
an outlet grille complete with adjustable
horizontal louvres.
VRBD heaters discharge warm air in two
opposing directions potentially enhancing
distribution whilst reducing capital and
installation costs for certain applications.
VRE heaters are downward discharging
units that can provide both heating and
de-stratification.
VRC heaters are designed for ducted
applications and are fitted with a
centrifugal fan(s) and have a duct spigot
outlet. Louvres and downflow can be
supplied as an option.
VRBD Bi-directional unit
VRE Downflow discharge unit
VRA Horizontal unit
Gas Fired Unit Heaters....................................................................................................................................................
....................................................................................................................................................
Variante
28
Variante Optional EquipmentDescription 12
£20£
30£
42£
50£
60£
72£
95£
120£
145£
BurnerTwo stage (high/low)Modulating (0-10v)
AllAll
139356
139356
139356
139356
139356
139356
139356
139356
233659
233659
Heat exchangerStainless steel heat exchanger All 91 108 174 214 269 276 301 352 442 506
Fan motorCentrifugal fan - 250 ESP at std airflowCentrifugal fan - 500 ESP at std airflow None standard airflows and ESP
VRCVRC VRC
167251
167251
188295
188295
208418
208418
295629
295629
375804
375804
Air outlet dischargeVertical louvresHorizontal louvres30° downflow head90° downflow head
VRAVRC
VRA & VRCVRC
414890
166
414890
166
414890
166
495495
166
555998
184
6761
105212
8064
117244
10554
120282
13066
198332
15767
233344
ThermostatAir recirculation thermostat All 71 71 71 71 71 71 71 71 71 71
FiltersFan cabinet with panel filtersFan cabinet, filters, mixing box no dampers
VRCVRC
256383
269404
292439
300457
336514
389594
438674
509778
6831100
7811251
Air inlet connectionTop mounted flue/combustion air spigots VRA/C 56 56 56 56 56 56 59 59 59 59
Dampers2 position damper motor (each)Modulating damper motor (each)Inlet dampers (each)Recirculation damper
VRCVRCVRCVRC
145303159159
145303159159
145303191191
145303191191
145303239239
145303239239
145303286286
145303286286
145303383383
145303383383
ControlsSmartCom SZ control panel c/w int.sensorSmartCom MZ control panel c/w int. sensorRemote room sensor (for use with SmartCom)
AllAllAll
23232551
23232551
23232551
23232551
23232551
23232551
23232551
23232551
23232551
23232551
Mounting bracketsWall mounting bracketsWall mounting brackets
VRAVRC
113147
113147
113147
113147
113147
113147
147188
147188
188223
188223
Underbeam kitsHeater parallel to beamHeater 90° to beam
VRA/BD/C/EVRA/BD/C/E
199199
199199
199199
199199
199199
199199
219219
219219
264264
264264
Sundries½'' BSP gas valve¾'' BSP gas valve½'' Flexible connection¾'' Flexible connection
AllAllAllAll
13-
35-
13-
35-
13-
35-
13-
35-
13-
35-
13-
35-
-15
-42
-15
-42
-15
-42
-15
-42
Variante Notes:Heaters supplied suitable for natural gas as standard. LPG G31 free of charge option if required should be specified on order.High/Low burner and 0-10V modulation require SmartCom MZ control.With 0-10V modulating burner we recommend stainless steel heat exchanger is specified.All control options are remote, all interconnecting wiring by others.VRBD models have top mounted flue and combustion air spigots as standard. VRA (HAF) high airflow fan usually for industrial use only.CP2 and CP4 controllers can be specified at the same cost as SmartCom, CP4 remote sensor priced at £130.
Variante Gas Fired Unit Heaters - VRA/BD/C/E/HAModel Nominal
Heat Output
kW
Airflow m3/h
Std ESP VRC
Flue Dia Ø mm
VRA Axial Fan
List Price £
VRBDAxial Fan
Bi-Directional List Price £
VRCCentrifugal Fan
List Price £
VREDownflow
Axial FanList Price £
VRA HAIndustrial High
Airflow FanList Price £
12 12.0 1116 100 80 1158.00 - 1386.00 1170.00 1170.00
20 20.0 1980 125 80 1225.00 - 1433.00 1236.00 1236.00
30 29.0 2844 100 100 1349.00 - 1651.00 1422.00 1422.00
42 39.0 3456 150 100 1556.00 - 1817.00 1570.00 1570.00
50 49.0 4356 150 100 1722.00 - 2136.00 1738.00 1738.00
60 59.0 5544 180 100 1929.00 - 2363.00 1986.00 1986.00
72 72.0 6840 150 130 2300.00 2601.00 2558.00 2344.00 2344.00
95 96.0 8136 180 130 2685.00 3075.00 3086.00 2886.00 2886.00
120 120.0 11088 200 130 3376.00 3648.00 4016.00 3442.00 3442.00
145 144.0 13608 200 130 3805.00 3950.00 4138.00 3920.00 3920.00
Please Contact Technical Sales with Requirements
29
Gas fired unit heaters..................................................................................................
..................................................................................................
BENSON
AccessoriesModel 80mm Dia 100mm Dia 130mm Dia
Horizontal flue terminal guard basket All 39-15-001
17.0039-15-001
17.0039-15-001
17.00
High temperature flexible flashing Std Dia B-RFK-4
43.00B-RFK-4
43.00B-RFK-4
43.00
High temperature flexible flashing Co-Axial B-RFK-4
43.00B-RFK-6
54.00B-RFK-7
90.00
Variante Stainless Steel Flue Notes:VRA/C-TE = VRA/C heater with top flue/combustion air spigot option.Horizontal kits include, where necessary any fittings to convert the flue and combustion air spigots into the horizontal plane.Vertical kits include, where necessary any fittings to convert the flue and combustion air spigots into the vertical plane.To comply with certification heaters configured in room sealed mode must use flue components from the listing above.
UESA, UDSA-B & Variante Stainless Steel FluesOption 1 - Fan Assisted Flue Only
Model 80mm Dia 100mm Dia 130mm Dia
Horizontal flue terminal Part No.
List Price £33-54-006
89.0033-54-106
104.0033-54-206
111.00
Vertical flue terminal Part No.
List Price £33-54-007
30.0033-54-107
44.0033-54-207
45.00
To connect between terminal and heater -
1000 mm straight pipe Part No.
List Price £33-54-001
22.0033-54-101
24.0033-54-201
34.00
500 mm straight pipe Part No.
List Price £33-54-002
16.0033-54-102
17.0033-54-202
23.00
250 mm straight pipe Part No.
List Price £33-54-003
13.0033-54-103
14.0033-54-203
22.00
45° Bend Part No.
List Price £33-54-004
14.0033-54-104
15.0033-54-204
24.00
90° Bend Part No.
List Price £33-54-005
16.0033-54-105
20.0033-54-205
28.00
Option 3 - Variante Flue Kits
Model
Standard Diameter mm 80 100 130
Approx Co-Axial Diameter mm 125 150 200
Horizontal two pipe kit VRA/C B-VR12-20TP
137.00B-VR30-60TP
154.00B-VR72-145TP
171.00
Horizontal two pipe kit VRBD/E169.00
B-PV30-50TIP
194.00B-PV72-145TIP
271.00
Horizontal Co-Axial kit VRBD/E B-PV12-20CHFT
156.00B-PV30-50CHFT
194.00B-PV72-145CHFT
324.00
Vertical Co-Axial kit VRA/C B-VR12-20CVFT
193.00B-VR30-60CVFT
296.00B-VR72-145CVFT
447.00
UESA, UDSA-B & Variante Stainless Steel FluesOption 2 - Room Sealed Flue Components
Model 80mm Dia 100mm Dia 130mm Dia
Horizontal balanced flue terminal Part No.
List Price £33-55-009
124.0033-55-106
154.0033-55-206
224.00
Vertical balanced flue terminal Part No.
List Price £33-55-010
161.0033-55-107
232.0033-55-207
347.00
To connect between terminal and heater -
1000 mm straight pipe All 2 x 22.00 2 x 24.00 2 x 34.00
500 mm straight pipe All 2 x 16.00 2 x 17.00 2 x 23.00
250 mm straight pipe All 2 x 13.00 2 x 14.00 2 x 22.00
45° bend All 2 x 14.00 2 x 15.00 2 x 24.00
90° bend All 2 x 16.00 2 x 20.00 2 x 28.00
30
..................................................................................................
..................................................................................................
BENSONGas fired unit heaters
External Variante Optional EquipmentDescription 12
£20£
30£
42£
50£
60£
72£
95£
120£
145£
BurnerTwo stage (high/low)Modulating (0-10v)
AllAll
139356
139356
139356
139356
139356
139356
139356
139356
233659
233659
Heat exchangerStainless steel heat exchanger All std std std std std std std std std std
FiltersFan cabinet, filters, mixing box no dampers EVRC 383 404 439 457 514 594 674 778 1100 1251
Air inlet connectionFresh air inlet weather louvre EVRC 182 182 208 208 224 224 258 304 330 330
Dampers2 position damper motor IP54 (each)Modulating damper motor IP54 (each)Weatherproof Inlet dampers (each)Weatherproof recirculation damper
EVRCEVRCEVRCEVRC
147303175175
147303175175
147303209209
147303209209
147303263263
147303263263
147303314314
147303314314
147303420420
147303420420
ControlsSmartCom SZ control panel c/w int.sensorSmartCom MZ control panel c/w int. sensorRemote room sensor (for use with SmartCom)
AllAllAll
23232551
23232551
23232551
23232551
23232551
23232551
23232551
23232551
23232551
23232551
SundriesConstant fan relay All 62 62 62 62 62 62 62 62 62 62
External Variante
The compact highly efficient External Variante heaters provide cost effective heating for most commercial and industrial buildings, such as showrooms, factories and warehouses.
EVRC/D Units are weatherproof and suitable for rooftop or other outside locations. Model Range
The External Variante gas fired units are
available with heat outputs ranging from
12kW-144kW for use on natural gas (G20),
or propane (G31).
31
External gas fired unit heaters ..................................................................................................
..................................................................................................
BENSON
External / Rooftop Variante Gas Fired Unit Heaters - EVRC/EVRDModel Nominal
Heat Output
kW
StandardAirflow m3/h
EVRDMinimum Airflowm3/h
EVRDMaximum
Airflowm3/h
EVRCCentrifugal Fan
Standard Pressure List Price £
EVRC-250Centrifugal Fan 250 Pa Pressure
List Price £
EVRC-500Centrifugal Fan 500 Pa Pressure
List Price £
EVRDDuct Package
No FanList Price £
12 12.0 1116 900 1800 2406.00 2581.00 2668.00 2104.00
20 20.0 1980 1512 2988 2466.00 2642.00 2730.00 2158.00
30 29.0 2844 2160 4356 2772.00 2969.00 3081.00 2339.00
42 39.0 3456 2916 5868 2998.00 3195.00 3305.00 2576.00
50 49.0 4356 3672 7344 3399.00 3619.00 3840.00 2708.00
60 59.0 5544 4428 8856 3590.00 3810.00 4029.00 2821.00
72 72.0 6840 5400 10800 4475.00 4782.00 5133.00 3656.00
95 96.0 8136 7200 14400 5016.00 5324.00 5676.00 3815.00
120 120.0 11088 9000 18000 5936.00 6053.00 6267.00 4536.00
145 144.0 13608 10800 21600 6234.00 6369.00 6671.00 4751.00
OUHA units are fitted with a high capacity axial fan for optimum air distribution. The OUHA 60-100 models are fitted with twin fans.
OUHC models have a centrifugal fan for ducted installations and are supplied with a duct outlet spigot. Outlet louvres are available as an option.
Model RangeThe OUH Series oil fired heaters are
available in six heat outputs ranging from
31kW to 100kW, for use on 35 seconds oil.
Alternatively, units may be specified for use
with Kerosene (28 seconds).
Oil Fired Unit Heaters....................................................................................................................................................
....................................................................................................................................................
OUH
32
OUHA Axial Fan & OUHC Centrifugal FanModel Nominal Heat
Output kWAirflow m3/h
Std ESP OUHC
Flue Dia Ø mm
OUHA List Price £
OUHC List Price £
OUH 30 31.0 3240 150 125 2207.00 2424.00
OUH 40 39.0 3672 150 125 2229.00 2479.00
OUH 60 59.0 5760 180 150 2532.00 2862.00
OUH 70 70.0 6840 150 150 2721.00 3238.00
OUH 90 88.0 8784 180 175 3100.00 3728.00
OUH 100 100.0 9468 180 175 3269.00 3897.00
OUHA & OUHC Optional EquipmentDescription 30
List Price £40
List Price £60
List Price £70
List Price £90
List Price £100
List Price £
BurnerTwo stage (high/low) burner All - - 896.00 896.00 896.00 812.00
Heat exchangerStainless steel All 194.00 194.00 359.00 359.00 576.00 576.00
Air outlet dischargeVertical louvresHorizontal louvres30o downflow90o downflow
OUHA OUHCOUHC OUHC
49.0035.0090.00
167.00
49.0035.0096.00
167.00
80.0044.00
118.00244.00
80.0044.00
118.00281.00
129.0072.00
197.00331.00
129.0072.00
232.00343.00
Lined fan cabinetBlower cabinet with filtersBlower cabinet, mixing box & filters
OUHCOUHC
339.00487.00
350.00497.00
518.00716.00
558.00755.00
756.00977.00
885.001075.00
DampersInlet dampers (each) OUHC 191.00 191.00 287.00 287.00 382.00 382.00
33
Oil fired unit heaters ..................................................................................................
..................................................................................................
BENSON
OUHA & OUHC Optional Equipment ContinuedDescription 30
List Price £40
List Price £60
List Price £70
List Price £90
List Price £100
List Price £
Damper controls2 Position damper motor (each)Modulating damper motor (each)
OUHC OUHC
145.00303.00
145.00303.00
145.00303.00
145.00303.00
145.00303.00
145.00303.00
ControlsSmartCom SZ control c/w int. sensorSmartCom MZ control c/w int. sensorRemote room sensor
AllAllAll
232.00325.00
51.00
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
232.00325.0051.00
Mounting bracketsWall mounting bracketsWall mounting brackets
OUHA OUHC
113.00147.00
113.00147.00
147.00188.00
147.00188.00
188.00223.00
188.00223.00
Underbeam kitsHeater parallel to beamHeater 90o to beam
AllAll
199.00199.00
199.00199.00
219.00219.00
219.00219.00
264.00264.00
264.00264.00
Combustion airCombustion air adaptor
Ø mmAll
12580.00
12580.00
12580.00
12580.00
15096.00
15096.00
Single Wall Stainless Steel Flue Pipe Grade 304 stainless steel, for use on oil fired unit heaters
Flue diameter Ø mm
125 150 175
Starter Kit (1 x universal cowl, 1 x 1m pipe, 1 x 1m changeover section, 1 x storm collar, 1 x flexible flashing kit)
Part No.
List Price £SWFK125
212.00SWFK150
227.00SWFK175
247.00
500mm flue pipePart No.
List Price £33-51-201
23.0033-51-301
25.0033-51-401
27.00
1m flue pipePart No.
List Price £33-51-202
35.0033-51-302
37.0033-51-402
39.00
1m changeover sectionPart No.
List Price £33-51-205
44.0033-51-305
45.0033-51-405
47.00
Elbow 45°Part No.
List Price £33-51-208
23.0033-51-308
24.0033-51-408
26.00
Elbow 90°Part No.
List Price £33-51-209
31.0033-51-309
33.0033-51-409
34.00
90° tee (condensate)Part No.
List Price £33-51-207
47.0033-51-307
49.0033-51-407
52.00
135° tee (condensate)Part No.
List Price £33-51-206
53.0033-51-306
54.0033-51-406
55.00
Adjustable roof platePart No.
List Price £33-51-210
43.0033-51-310
43.0033-51-410
44.00
Storm collarPart No.
List Price £33-51-211
20.0033-51-311
22.0033-51-411
22.00
Standard cowlPart No.
List Price £33-51-214
41.0033-51-314
44.0033-51-414
49.00
Universal terminal Part No.
List Price £33-51-215
71.0033-51-315
81.0033-51-415
85.00
Wall bracketPart No.
List Price £33-51-216
12.0033-51-316
13.0033-51-416
13.00
Joint clamp bandPart No.
List Price £33-51-217
12.0033-51-317
14.0033-51-417
14.00
High temperature flexible flashing c/w fix kitPart No.
List Price £B-RFK-4
43.00B-RFK-4
43.00B-RFK-6
54.00
High temperature flexible flashing with fixing kit for deep profile corrugated sheets
Part No.
List Price £B-RFK-4
43.00B-RFK-6
54.00B-RFK-6
54.00
SpecificationCabinet
Cabinets are constructed from electro-zinc
coated steel with an inner heat shield skin
and an epoxy powder coat finish outer skin
to form a rigid and durable casework.
Electric Motors
All electric motors comply with EC motor
directive 2005/32/EC.
Heat Exchanger
Four pass combustion chamber/heat
exchanger assembly provides improved
thermal efficiency with extended life
expectancy. A stainless steel chamber is
combined with a high efficiency tubular
heat exchanger to achieve thermal
efficiency in excess of 91%.
The complete assembly is mounted to allow
for thermal expansion thereby avoiding
undue thermal stress and premature heat
exchanger failure.
Burner
Gas fired units are fitted with a fully
automatic forced draught burner complete
with full safety controls to EN676 and the
heaters are CE certified. A high/low burner
is fitted as standard on model 375.
Oil fired units are supplied complete with
a fully automatic burner including safety
controls and factory fitted fire valve and
oil filter. An additional external fire valve
may be required in accordance with BS
410:Part2:1978.
Cabinet Heaters
Cabinet heaters combine innovative design with a proven four pass heat exchanger technology to provide a high efficiencycost effective and durable range.
The units may be specified for either free blowing applications or for use with ductwork.
Model Range
> Gas fired cabinet heaters are suitable
for use with Natural Gas (G20), most
units can also be specified for Propane
(G31)
> Oil fired cabinet heaters are suitable
for use with Class D gas oil (35 sec),
most units can also be specified for
Kerosene (28 sec oil). Oil fired cabinets
are supplied complete with factory
fitted fire valve and oil filter
Vertical freestanding models are available
from 29kW to 380kW.
Horizontal and Down flow models from
58kW to 380kW.
Options
> Combustion air adaptors
> Stainless steel tubular heat exchanger
> Air inlet spigots
> Air inlet filters
> Manual or motorised inlet dampers
> Up-rated fan motor for increased static
pressure
....................................................................................................................................................
34
Gas Fired Cabinet Heaters Vertical Horizontal Downflow
Model Nominal Heat Output
kW
Airflow m3/h
Std ESP Ducted
DG
Flue Dia Ø mm
VNG Nozzled unit
List Price £
VDG Ducted unit List Price £
HNG Nozzled unit
List Price £
HDG Ducted unit
List Price £
RNG Nozzled unit
List Price £
RDGDucted unit List Price £
30 29.0 2196 75 125 3066.00 3007.00 - - - -
35 36.0 2556 100 125 3140.00 3080.00 - - - -
40 40.0 2556 100 125 3234.00 3175.00 - - - -
60 58.0 3708 125 150 3444.00 3371.00 3927.00 3854.00 3927.00 3854.00
75 73.0 5004 100 150 3728.00 3657.00 4001.00 3926.00 4001.00 3926.00
85 83.0 5004 100 175 3770.00 3695.00 4011.00 3940.00 4011.00 3940.00
120 117.0 7740 137 175 4610.00 4512.00 4914.00 4816.00 4914.00 4816.00
135 133.0 9540 150 175 5187.00 5058.00 5313.00 5184.00 5313.00 5184.00
180 177.0 11196 175 200 5397.00 5264.00 5702.00 5568.00 5702.00 5568.00
205 206.0 12240 188 200 6006.00 5874.00 6363.00 6231.00 6363.00 6231.00
235 237.0 15552 125 225 7035.00 6866.00 7466.00 7296.00 7466.00 7296.00
275 278.0 17496 175 225 7592.00 7422.00 7749.00 7580.00 7749.00 7580.00
350 350.0 24768 250 250 12723.00 12961.00 13499.00 13745.00 13499.00 13745.00
375 380.0 24768 250 250 14453.00 14692.00 16343.00 16588.00 16343.00 16588.00
Horizontal Cabinet
35
Cabinet heaters..................................................................................................
..................................................................................................
BENSON
Air Distribution
Centrifugal fan(s) circulate large air volumes
evenly across the full heat exchanger
surface for enhanced life expectancy. Fans on
models 30 to 85 are direct drive with a single
phase motor whilst larger models are fitted
with a three phase motor and v-belt drive.
Free blowing heaters are fitted with long
throw discharge nozzles complete with
horizontal louvres and can be rotated
through 360o. Models 75-375 are supplied
with a raised rear nozzle (one per three
nozzle heater and two per four nozzle
heater).
Heaters for use with ductwork are
supplied with a duct outlet spigot.
Vertical Cabinet
Cabinet Heaters Optional Equipment Description 30
£35£
40£
60£
75£
85£
120£
135£
180£
205£
235£
275£
350£
375£
FuelPropane conversion 41 41 41 41 41 41 41 41 41 93 93 93 204 204
Electrical supplyWired single phaseWired three phase
std-
std-
std-
std112
std112
std112
198std
198std
-std
-std
-std
-std
-std
-std
BurnerTwo stage (high/low) - GasTwo stage (high/low) - OilModulating - Gas
---
---
---
1056925
2310
1056925
2310
1056925
2310
887839
2119
887801
2119
1219801
2119
1915865
2085
1915865
3902
1915865
3902
2091std
3307
stdstd
P.O.A
Heat exchangerStainless steel 174 174 174 262 262 262 445 445 478 478 923 923 1114 1114
Fan motor200 ESP upgrade (ducted)400 ESP upgrade (ducted)600 ESP upgrade (ducted)
---
---
---
-964
-
-964
-
-964
-
249444920
356444920
370528
1488
420528
1488
47218092095
55418092095
std27252725
std27252725
Air outlet dischargeRaised outlet nozzle(s) (nozzled) - - - - f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c f.o.c
FiltersInlet filter assembly 416 416 416 448 448 448 541 555 555 555 633 633 663 663
Air inlet connectionSide inlet duct spigotRear inlet duct spigot End inlet duct spigot (HN/RN)
7878inc
7878inc
7878inc
9898inc
9898inc
107107inc
107107inc
107107inc
107107inc
107107 inc
173173inc
173173inc
237-
inc
237-
inc
DampersManual dampers (each)2 position damper motor (each)Modulating damper motor (each)
231150308
231150308
231150308
296150308
296150308
296150308
386150308
386150308
494150308
494150308
593150308
593150308
657150308
657150308
Combustion airCombustion air adaptor 80 80 80 80 80 96 96 96 96 96 96 96 109 109
ControlsSmartCom MZ control upgradeRemote warm air sensor (loose)Heater less controls
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
std51
-139
SundriesKit form heater*Constant running fan relay
63662
63662
63662
78862
78862
78862
90962
90962
99762
99762
102962
102962
131462
131462
Oil Fired Cabinet Heaters Vertical Horizontal Downflow
Model Nominal Heat Output
kW
Airflow m3/h
Std ESP Ducted
DO
Flue Dia Ø mm
VNO Nozzled unit
List Price £
VDO Ducted unit List Price £
HNO Nozzled unit
List Price £
HDO Ducted unit
List Price £
RNO Nozzled unit
List Price £
RDODucted unit List Price £
30 32.0 2196 75 125 2422.00 2367.00 - - - -
35 38.0 2556 100 125 2497.00 2441.00 - - - -
40 43.0 2556 100 125 2520.00 2464.00 - - - -
60 60.0 3708 125 150 2937.00 2881.00 3242.00 3188.00 3242.00 3188.00
75 76.0 5004 100 150 3063.00 2993.00 3382.00 3312.00 3382.00 3312.00
85 82.0 5004 100 175 3100.00 3029.00 3415.00 3343.00 3415.00 3343.00
120 123.0 7740 137 175 3890.00 3800.00 4310.00 4214.00 4310.00 4214.00
135 138.0 9540 150 175 4611.00 4489.00 4712.00 4592.00 4712.00 4592.00
180 184.0 11196 175 200 4800.00 4674.00 5078.00 4955.00 5078.00 4955.00
205 208.0 12240 188 200 5249.00 5122.00 5663.00 5539.00 5663.00 5539.00
235 248.0 15552 125 225 6512.00 6353.00 6622.00 6470.00 6622.00 6470.00
275 265.0 17496 175 225 6822.00 6661.00 6989.00 6837.00 6989.00 6837.00
350 350.0 24768 250 250 11013.00 11251.00 12105.00 12344.00 12105.00 12344.00
375 380.0 24768 250 250 11188.00 11426.00 12933.00 13182.00 12933.00 13182.00
*Kit form heater option is available for internal heaters only. The price includes the costs of breaking down the heater, additional packing material and instructions for re-assembly etc. Re-assembly on site is not included. For details and dimensions please contact our sales office.With 0-10V modulating burner we recommend stainless steel heat exchanger is specified.36
..................................................................................................
..................................................................................................Cabinet heaters
BENSON
Single Wall Stainless Steel Flue PipeGrade 304 stainless steel, for use on gas and oil fired cabinet heaters
Flue diameter Ø mm
125 150 175 200 225 250
Starter Kit (1 x universal cowl, 1 x 1m pipe, 1 x 1m changeover section, 1 x storm collar, 1 x flexible flashing kit)
Part No.
List Price £SWFK125
212.00SWFK150
227.00SWFK175
247.00SWFK200
264.00SWFK225
319.00SWFK250
333.00
500mm flue pipePart No.
List Price £33-51-201
23.0033-51-301
25.0033-51-401
27.0033-51-501
28.0033-51-601
31.0033-51-701
34.00
1m flue pipePart No.
List Price £33-51-202
35.0033-51-302
37.0033-51-402
39.0033-51-502
46.0033-51-602
48.0033-51-702
53.00
1m changeover sectionPart No.
List Price £33-51-205
44.0033-51-305
45.0033-51-405
47.0033-51-505
51.0033-51-605
59.0033-51-705
65.00
Elbow 45°Part No.
List Price £33-51-208
23.0033-51-308
24.0033-51-408
26.0033-51-508
28.0033-51-608
29.0033-51-708
34.00
Elbow 90°Part No.
List Price £33-51-209
31.0033-51-309
33.0033-51-409
34.0033-51-509
36.0033-51-609
38.0033-51-709
40.00
90° tee (condensate)Part No.
List Price £33-51-207
47.0033-51-307
49.0033-51-407
52.0033-51-507
56.0033-51-607
57.0033-51-707
60.00
135° tee (condensate)Part No.
List Price £33-51-206
53.0033-51-306
54.0033-51-406
55.0033-51-506
61.0033-51-606
65.0033-51-706
78.00
Adjustable roof platePart No.
List Price £33-51-210
43.0033-51-310
43.0033-51-410
44.0033-51-510
45.0033-51-610
47.0033-51-710
50.00
Storm collarPart No.
List Price £33-51-211
20.0033-51-311
22.0033-51-411
22.0033-51-511
23.0033-51-611
25.0033-51-711
27.00
Standard cowlPart No.
List Price £33-51-214
41.0033-51-314
44.0033-51-414
49.0033-51-514
51.0033-51-614
54.0033-51-714
64.00
Universal terminal Part No.
List Price £33-51-215
71.0033-51-315
81.0033-51-415
85.0033-51-515
90.0033-51-615
97.0033-51-715
98.00
Wall bracketPart No.
List Price £33-51-216
12.0033-51-316
13.0033-51-416
13.0033-51-516
14.0033-51-616
15.0033-51-716
17.00
Joint clamp bandPart No.
List Price £33-51-217
12.0033-51-317
14.0033-51-417
14.0033-51-517
16.0033-51-617
16.0033-51-717
17.00
High temperature flexible flashing c/w fix kitPart No.
List Price £B-RFK-4
43.00B-RFK-4
43.00B-RFK-6
54.007700H-2
54.00B-RFK-7
90.00B-RFK-7
90.00
High temperature flexible flashing with fixing kit for deep profile corrugated sheets
Part No.
List Price £B-RFK-4
43.00B-RFK-6
54.00B-RFK-6
54.00B-RFK-7
90.00B-RFK-7
90.00B-RFK-8
105.00
37
Cabinet heaters..................................................................................................
..................................................................................................
BENSON
Gas Fired External Cabinet Heaters Vertical Horizontal
Model Nominal Heat Output
kW
Airflow m3/h
Std ESP Ducted
EVDG Ducted unit List Price £
EHDG Ducted unit
List Price £
30 29.0 2196 75 5542.00 -
35 36.0 2556 100 5887.00 -
40 40.0 2556 100 5913.00 -
60 58.0 3708 125 6591.00 6849.00
75 73.0 5004 100 6843.00 7058.00
85 83.0 5004 100 6862.00 7073.00
120 117.0 7740 137 8132.00 8557.00
135 133.0 9540 150 8757.00 9286.00
180 177.0 11196 175 9336.00 9776.00
205 206.0 12240 188 10051.00 10728.00
235 237.0 15552 125 11754.00 12341.00
275 278.0 17496 175 12430.00 12797.00
350 350.0 24768 250 19837.00 22246.00
375 380.0 24768 250 23009.00 23942.00
External cabinet heaters combine innovative design with a proven four pass heat exchanger technology to provide a high efficiency cost effective and durable range.
External cabinets provide the ideal solution for a wide range of industrial and commercial applications where space or environmental criteria restrict the use of internally sited units.
Model Range
Cabinet heaters are available as either gas
or oil fired models.
> Gas fired cabinet heaters are suitable
for use with Natural Gas (G20), most
units can also be specified for Propane
(G31)
> Oil fired cabinet heaters are suitable
for use with Class D gas oil (35 sec),
most units can also be specified for
Kerosene (28 sec oil)
External Cabinet Heaters
....................................................................................................................................................
38
External Cabinet Heaters Optional Equipment Description 30
£35£
40£
60£
75£
85£
120£
135£
180£
205£
235£
275£
350£
375£
FuelPropane conversion 41 41 41 41 41 41 41 41 41 93 93 93 204 204
Electrical supplyWired single phaseWired three phase
std-
std-
std-
std112
std112
std112
198std
198std
-std
-std
-std
-std
-std
-std
BurnerTwo stage (high/low) - GasTwo stage (high/low) - OilModulating - Gas
---
---
---
1056925
2310
1056925
2310
1056925
2310
887839
2119
887801
2119
1219801
2119
1915865
2085
1915865
3902
1915865
3902
2091std
3307
stdstd
P.O.A
Heat exchangerStainless steel std std std std std std std std std std std std std std
Fan motor200 ESP upgrade (ducted)400 ESP upgrade (ducted)600 ESP upgrade (ducted)
---
---
---
-964
-
-964
-
-964
-
249444920
356444920
370528
1488
421528
1488
47218092095
55418092095
std27252725
std27252725
FiltersInlet filter assembly (see note)Inlet weather hood
416138
416138
416138
448148
448148
448148
541179
555184
555184
555184
633209
633209
663219
663219
Air inlet connectionSide inlet duct spigotRear inlet duct spigot End inlet duct spigot (HN/RN)
7878inc
7878inc
7878inc
9898inc
9898inc
107107inc
107107inc
107107inc
107107inc
107107 inc
173173inc
173173inc
237-
inc
237-
inc
DampersManual dampers (each)2 position damper motor (each)Modulating damper motor (each)
231150308
231150308
231150308
296150308
296150308
296150308
386150308
386150308
494150308
494150308
593150308
593150308
677150308
677150308
ControlsSmartCom MZ control upgradeRemote warm air sensor (loose)Heater less controls
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
9351
-139
std51
-139
SundriesConstant running fan relay 62 62 62 62 62 62 62 62 62 62 62 62 62 62
Oil Fired External Cabinet Heaters Vertical Horizontal
Model Nominal Heat Output
kW
Airflow m3/h
Std ESP Ducted EVDO Ducted unit List Price £
EHDO Ducted unit
List Price £
30 32.0 2196 75 4641.00 -
35 38.0 2556 100 4851.00 -
40 43.0 2556 100 5054.00 -
60 60.0 3708 125 5564.00 5874.00
75 76.0 5004 100 5693.00 6008.00
85 82.0 5004 100 5769.00 6077.00
120 123.0 7740 137 7181.00 7572.00
135 138.0 9540 150 8092.00 8182.00
180 184.0 11196 175 8513.00 8760.00
205 208.0 12240 188 8988.00 9522.00
235 248.0 15552 125 10681.00 11022.00
275 265.0 17496 175 11477.00 11687.00
350 350.0 24768 250 18453.00 20342.00
375 380.0 24768 250 18782.00 20874.00
Cabinet Notes:Heaters configured as; oil - 35 second (28 second also available on certain models), gas - natural gas (G20) (LPG - propane (G31) also available on certain models)SmartCom SZ standard controller includes password protection, digital time switch with override facility, electronic day/night thermostats and fan only facility.CP2 and CP4 are available as an option at the same cost as SmartCom.SmartCom MZ selection obligatory for High/Low burner options.Vertical heater - controls heater mounted. Horizontal and reverse flow heater controls supplied in remote format, interconnecting wiring by others.All oil fired cabinet heaters are supplied with a factory fitted fusible link, fire safety valve and oil line filter.Modulating burner options includes SmartCom MZ control upgrade as standard.External heater inlet filter assembly includes weatherproof housing and 45o weather-hood inlet grille
39
External cabinet heaters..................................................................................................
..................................................................................................
BENSON
Room Sealed Gas Fired Cabinet HeatersModel Nominal
Heat Output kW
Airflow m3/h
Std ESP PVD
Flue Dia Ø mm
PVN Vertical Nozzled Unit
List Price £
PVD Vertical Ducted Unit
List Price £
PV 30 29.0 2880 80 100 2235.00 2157.00
PV 50 49.0 3780 110 100 2815.00 2735.00
PV 72 72.0 5400 100 130 3260.00 3193.00
PV 95 96.0 8280 130 130 3615.00 3544.00
PV 120 120.0 10980 150 130 4226.00 4140.00
PV 145 144.0 13176 150 130 5385.00 5274.00
PV Optional EquipmentDescription 30
List Price £50
List Price £72
List Price £95
List Price £120
List Price £145
List Price £
Electrical supplyWired single phaseWired three phase
std-
std-
std-
198.00std
198.00std
198.00std
BurnerTwo stage ((high/low) c/w SmartCom3 MZ)Modulating (0-10V) c/w SmartCom3 MZ
277.00356.00
277.00356.00
277.00356.00
277.00356.00
373.00659.00
373.00659.00
Heat exchangerStainless steel 174.00 269.00 301.00 390.00 442.00 506.00
Fan motor200 ESP upgrade (PVD) - - 291.00 225.00 245.00 351.00
Air outlet dischargeRaised outlet nozzle(s) (PVN) - - - f.o.c f.o.c f.o.c
FiltersSide inlet filter assembly
416.00 448.00 448.00 448.00 541.00
555.00
Air inlet connectionSide inlet duct spigotRear inlet duct spigot
78.0078.00
78.0078.00
96.0096.00
109.00109.00
109.00109.00
109.00109.00
DampersManual dampers (each)2 position damper motor (each)Modulating damper control (each)
231.00150.00308.00
231.00150.00308.00
296.00150.00308.00
296.00150.00308.00
395.00150.00308.00
395.00150.00308.00
ControlsSmartCom3 MZ control upgradeRemote warm air sensor (loose)Heater less controls
93.0051.00
-139.00
93.0051.00
-139.00
93.0051.00
-139.00
93.0051.00
-139.00
93.0051.00
-139.00
93.0051.00
-139.00
Suitable for free blowing applications PVN models are supplied complete with adjustable discharge nozzles. For ducted air installations PVD units are supplied complete with duct outlet spigot.
Model RangeThe PV cabinets are available in six heat
outputs from 29kW to 144kW. Standard
units are suitable for natural gas (G20) and
units may also be specified as an option to
operate on Propane (G31). Units are
supplied with SmartCom SZ control factory
fitted.
The PV range has a fan assisted flue and is
suitable for balanced flue or standard fan
assisted flue installation using either wall or
roof terminals.
High Efficiency Cabinet Heaters.........................................................................................................
.........................................................................................................
PV
40
..................................................................................................
..................................................................................................High efficiency cabinet heaters
BENSON
With 0-10V modulating burner we recommend stainless steel heat exchanger is specified.
PV Stainless Steel FluesOption 1 - Fan Assisted Flue Only
Model 100mm Dia 130mm Dia
Horizontal flue terminal Part No.
List Price £33-54-106
104.0033-54-206
111.00
Vertical flue terminal Part No.
List Price £33-54-107
44.0033-54-207
45.00
To connect between terminal and heater -
1000 mm straight pipe Part No.
List Price £33-54-101
24.0033-54-201
34.00
500 mm straight pipe Part No.
List Price £33-54-102
17.0033-54-202
23.00
250 mm straight pipe Part No.
List Price £33-54-103
14.0033-54-203
22.00
45° Bend Part No.
List Price £33-54-104
15.0033-54-204
24.00
90° Bend Part No.
List Price £33-54-105
20.0033-54-205
28.00
Option 3 - PV Flue Kits
Model
Standard Diameter mm 100 130
Approx Co-Axial Diameter mm 150 200
Horizontal two pipe kit Part No.
List Price £B-PV30-50TIP
194.00B-PV72-145TIP
271.00
Horizontal Co-Axial kit Part No.
List Price £B-PV30-50CHFT
194.00B-PV72-145CHFT
324.00
PV Stainless Steel FluesOption 2 - Room Sealed Flue Components
Model 100mm Dia 130mm Dia
Horizontal balanced flue terminal Part No.
List Price £33-55-106
154.0033-55-206
224.00
Vertical balanced flue terminal Part No.
List Price £33-55-107
232.0033-55-207
347.00
To connect between terminal and heater -
1000 mm straight pipe All 2 x 24.00 2 x 34.00
500 mm straight pipe All 2 x 17.00 2 x 23.00
250 mm straight pipe All 2 x 14.00 2 x 22.00
45° bend All 2 x 15.00 2 x 24.00
90° bend All 2 x 20.00 2 x 28.00
AccessoriesModel 100mm Dia 130mm Dia
Horizontal flue terminal guard basket Part No.
List Price £All 39-15-001
17.0039-15-001
17.00
High temperature flexible flashing Part No.
List Price £Std Dia B-RFK-4
43.00B-RFK-4
43.00
High temperature flexible flashing Part No.
List Price £Co-Axial B-RFK-6
54.00B-RFK-7
90.00
41
High efficiency cabinet heaters..................................................................................................
..................................................................................................
BENSON
EnviroAir SDH/SHH units are primarily for ducted installations to provide either heating or combined heating and ventilation.
Used in conjunction with Smartcom controls the units can provide automatic control of input fresh air volume and temperature to suit the requirements of the building in both summer and winter conditions.
The units are available as SDH non condensing heaters, with thermal efficiencies in excess of 91%, or SHH fully condensing heaters with thermal efficiencies of up to 102.6% (ncv).
Model Range
SDH models are available with a short fan
cabinet for applications requiring a simple
return air or fresh air connection without
filters.
Alternatively SDH units can be supplied
with an extended fan cabinet to allow
filters and fresh air/recirculation air dampers
to be added for full ventilation control.
SHH condensing units are supplied as
standard with extended fan cabinets.
External static pressure up to 400 pascals,
dependent on motor size selected and
options fitted.
Features & BenefitsFeatures
> SDH / SHH incorporate patented Tcore2
4-pass heat exchanger technology for
optimum efficiency and enhanced life
expectancy
> Choice of titanium stabilised aluminised
steel or stainless steel heat exchanger
> Additional aluminium Macrochannel
heat exchanger in SHH models provides
fully condensing operation throughout
the full firing range
> Single burner with multi-try ignition
provides enhanced reliability
Indirect Gas Fired Heating & Ventilation Units....................................................................................................................................................
....................................................................................................................................................
EnviroAir
42
SDH Models with Short Fan CabinetModel Nominal
Heat Output kW
Standard Motor
kW
Flue Dia Ø mm
Aluminised steel Heat Exchanger
List Price £
Stainless Steel Heat Exchanger List Price £
SDH 25 25.6 0.25 100 3010.00 3081.00
SDH 30 29.2 0.25 100 3121.00 3229.00
SDH 35 34.9 0.25 100 3327.00 3458.00
SDH 43 42.1 0.25 100 3390.00 3539.00
SDH 55 54.7 0.37 130 3803.00 3994.00
SDH 73 73.0 0.55 130 4444.00 4703.00
SDH100 97.0 0.55 130 4968.00 5300.00
SDH Models with Extended Fan Cabinet for Optional Filters and DampersModel Nominal
Heat Output kW
Standard Motor
kW
Flue Dia Ø mm
Aluminised Steel Heat Exchanger
List Price £
Stainless Steel Heat Exchanger
List Price £
SDH 25 25.6 0.25 100 3322.00 3394.00
SDH 30 29.2 0.25 100 3438.00 3547.00
SDH 35 34.9 0.25 100 3644.00 3775.00
SDH 43 42.1 0.25 100 3734.00 3883.00
SDH 55 54.7 0.37 130 4145.00 4338.00
SDH 73 73.0 0.55 130 4817.00 5077.00
SDH100 97.0 0.55 130 5354.00 5685.00
SHH Gas Fired Condensing Heaters with Extended Fan Cabinet for Optional Filters and Dampers
Model Nominal Heat Output
kW
Standard Motor
kW
Flue Dia Ø mm
Aluminised Steel Heat Exchanger
List Price £
Stainless Steel Heat Exchanger List Price £
SHH 55 53.9 0.37 100 6219.00 6412.00
SHH 83 80.2 0.55 130 7226.00 7485.00
SHH 102 98.9 0.55 130 8030.00 8362.00
EnviroAir Motor Supplements SDH and SHH ModelsDescription 25 30 35 43 55 73 / 83 100 / 102
0.25kW 1ph std std std std - - -
0.37kW 1ph 36.70 36.70 21.90 21.90 std - -
0.55kW 1ph 51.50 51.50 28.60 28.60 5.10 std std
0.75kW 1ph 68.30 68.30 38.80 38.80 30.60 12.80 12.80
0.55kW 3ph 91.30 91.30 91.30 91.30 71.40 66.30 66.30
0.75kW 3ph 230.00 230.00 230.00 230.00 210.00 204.00 204.00
1.1kW 3ph 305.00 305.00 305.00 305.00 285.00 279.00 279.00
1.5kW 3ph - 335.00 335.00 335.00 315.00 309.00 309.00
2.2kW 3ph - 511.00 511.00 511.00 492.00 487.00 487.00
3.0kW 3ph - - 601.00 601.00 582.00 575.00 575.00
4.0kW 3ph - - - - 880.00 885.00 885.00
5.5kW 3ph - - - - - 1375.00 1375.00
43
Indirect gas fired heating & ventilation units ..................................................................................................
..................................................................................................
BENSON
EnviroAir SDH and SHH Optional EquipmentDescription 25 30 35 43 55 73 / 83 100 / 102
High/Low burnerModulating burner
167.00419.00
167.00419.00
167.00419.00
167.00419.00
167.00419.00
167.00419.00
167.00419.00
Horizontal louvres c/w frameVertical louvres30o Downturn nozzle c/w horizontal louvres60o Downturn nozzle c/w horizontal louvres
95.9051.50
145.00194.00
102.0069.90
149.00197.00
103.0073.40
153.00205.00
106.0073.40
156.00207.00
110.0073.40
159.00209.00
133.0084.20
188.00244.00
147.0088.20
217.00288.00
Fresh air damper c/w actuator and end switchPE insulated for short fan cabinet
470.00203.00
470.00217.00
470.00222.00
470.00222.00
487.00244.00
495.00261.00
540.00300.00
SDH and SHH Optional Equipment for Extended Cabinet Models OnlyDescription 25 30 35 43 55 73 / 83 100 / 102
Filter rack c/w 2’’ EU4 filters 102.00 129.00 131.00 137.00 148.00 181.00 237.00
Spigot connection top, rear or bottom 87.20 87.20 93.30 93.30 98.90 104.00 115.00
Fresh Air and recirc air dampers c/w spigot 441.00 499.00 499.00 502.00 502.00 608.00 635.00
Damper Actuator Open/Close 230V 282.00 282.00 282.00 282.00 282.00 282.00 282.00
Modulating damper actuator 24V c/w transformer 421.00 421.00 421.00 421.00 421.00 421.00 421.00
PE Insulation to extended fan cabinet 269.00 303.00 303.00 338.00 338.00 387.00 387.00
Acoustic insulation for blower cabinet 372.00 419.00 419.00 467.00 467.00 536.00 562.00
Additional Control RelaysDescription 25 30 35 43 55 73 / 83 100 / 102
Constant fan relay 34.70 34.70 34.70 34.70 34.70 34.70 34.70
Dirty filter indication 107.00 107.00 107.00 107.00 107.00 107.00 107.00
Air flow proving 107.00 107.00 107.00 107.00 107.00 107.00 107.00
44
AccessoriesDescription 25 30 35 43 55 73 / 83 100 / 102
SmartCom single zone control panel c/w int. sensor 232.00 232.00 232.00 232.00 232.00 232.00 232.00
SmartCom multi zone control panel c/w int. sensor 325.00 325.00 325.00 325.00 325.00 325.00 325.00
Remote room sensor (For use with SmartCom) 51.00 51.00 51.00 51.00 51.00 51.00 51.00
Duct air sensor (For use with SmartCom) 51.00 51.00 51.00 51.00 51.00 51.00 51.00
3/4" BSP gas valve 15.00 15.00 15.00 15.00 15.00 15.00 15.00
3/4" BSP flexible gas connection 43.00 43.00 43.00 43.00 43.00 43.00 43.00
..................................................................................................
..................................................................................................Indirect gas fired heating & ventilation units
BENSON
The portable air blower provides a versatile, portable form of ventilation for a wide range of applications including:
> Confined space ventilation
> Use on building and construction site
> Drainage areas
> Tank and silo venting
> Industrial applications
> Short term 'spot ventilation'
Specification
Robustly engineered from steel panel
construction with an epoxy powder coat
finish outer skin to form a rigid and durable
casework. Each air blower is fully
weatherproof to IP44 standard and is fitted
with a built-in carry handle.
The unit houses a continuous running axial
fan, which can be configured to operate
on 110v ac or 230v ac single phase. A 1.5
metre power cable and plug is fitted to the
unit. A 200mm diameter flexible duct 7
metres long can be provided with the unit
if required.
MH Marquee/Event Hire HeatersModel 100 150 150FT 200 300
Output (Max kW) 94 150 150 170 300
List Price £ List Price £ List Price £ List Price £ List Price £
On/Off 6675.00 10380.00 13637.00 - -
High/low air & heat - - - 12279.00 13574.00
Air Blower Notes:
Supply air ducting is supplied in two 3500mm Lengths with connecting clips
....................................................................................................................................................MH & Air BlowerThe MH series provides both short and long term temporary heating and drying solutions for a wide variety of applications including -
> Building and construction sites
> Corporate events
> Exhibition halls
> Industrial buildings
> Marquee
> Sports and leisure facilities
Model RangeThe MH units are available with heat
outputs ranging from 94kW - 300kW.
All models are indirect fired and provide
warm, dry, fume-free air readily
discharged directly into the heated area via
the quiet yet powerful centrifugal fan,
specifically selected to enable flexibility of
location and long ductwork runs.
The MH150FT unit has the benefit of an
in-built 520 litre PPG2/26 UN compliant oil
tank, offering 24 hours of continuous firing
at full load.
Air Blower (B110V)Model List Price £
110V Unit 351.00
203 dia adaptive ducting 252.00
230V Unit P.O.A
MH Notes:
MH heaters configured as; oil (35 second gas oil) or kerosene (28 second).
Fuel type to be specified at time of order.
Models 100 and 150 are configured for on/off operation. Models 200 and 300 are configured high/low for both heat output and airflow.
Heater supplied complete with primary flue section and terminal.
45
MH & air blower..................................................................................................
..................................................................................................
BENSON
Stainless Steel FluesOption 1 - Fan Assisted Flue Only
Model 80mm Dia 100mm Dia 130mm Dia
Horizontal flue terminal Part No.
List Price £33-54-006
89.0033-54-106
104.0033-54-206
111.00
Vertical flue terminal Part No.
List Price £33-54-007
30.0033-54-107
44.0033-54-207
45.00
To connect between terminal and heater -
1000 mm straight pipe Part No.
List Price £33-54-001
22.0033-54-101
24.0033-54-201
34.00
500 mm straight pipe Part No.
List Price £33-54-002
16.0033-54-102
17.0033-54-202
23.00
250 mm straight pipe Part No.
List Price £33-54-003
13.0033-54-103
14.0033-54-203
22.00
45° Bend Part No.
List Price £33-54-004
14.0033-54-104
15.0033-54-204
24.00
90° Bend Part No.
List Price £33-54-005
16.0033-54-105
20.0033-54-205
28.00
Stainless Steel FluesOption 2 - Room Sealed Flue Components
Model 80mm Dia 100mm Dia 130mm Dia
Horizontal balanced flue terminal Part No.
List Price £33-55-009
124.0033-55-106
154.0033-55-206
224.00
Vertical balanced flue terminal Part No.
List Price £33-55-010
161.0033-55-107
232.0033-55-207
347.00
To connect between terminal and heater -
1000 mm straight pipe All 2 x 22.00 2 x 24.00 2 x 34.00
500 mm straight pipe All 2 x 16.00 2 x 17.00 2 x 23.00
250 mm straight pipe All 2 x 13.00 2 x 14.00 2 x 22.00
45° bend All 2 x 14.00 2 x 15.00 2 x 24.00
90° bend All 2 x 16.00 2 x 20.00 2 x 28.00
....................................................................................................................................................Flue
AccessoriesModel 80mm Dia 100mm Dia 130mm Dia
Air inlet guard RCIG80
14.00RCIG100
15.00RCIG130
15.00
Horizontal flue terminal guard basket All 39-15-001
17.0039-15-001
17.0039-15-001
17.00
High temperature flexible flashing Std Dia B-RFK-4
43.00B-RFK-4
43.00B-RFK-4
43.00
High temperature flexible flashing Co-Axial B-RFK-4
43.00B-RFK-6
54.00B-RFK-7
90.00
46
Balanced Flue Installations
For balanced flue applications the terminal
provides both the fresh air for combustion
air and the flue outlet from a single
building penetration. The terminals are
ordered separately from the heaters to suit
either a wall outlet or roof outlet.
Additional flue and combustion air pipes
may be added up to the maximum
permissible length detailed in the product
literature.
To comply with CE approvals, balanced flue
appliances must be used with the
manufacturer’s balanced flue system.
All balanced flue heaters are also certified
for fan assisted flue installations, where the
combustion air is to be drawn from inside
the building or units installed in a ventilated
plant room. Roof and wall terminals for
fan assisted non balanced flue installations
should be selected from the list opposite
for these applications and also for balanced
flue applications using separated flue outlet
and combustion air inlet.
Flue Dimensions (mm)Model Vertical concentric flue terminal Horizontal concentric flue terminal
Ø80mm Ø100mm Ø130mm Ø80mm Ø100mm Ø130mm
A 1271 1361 1895 775 775 940
B 130 140 227 130 140 227
C n/a n/a n/a 80 100 130
D 125 150 200 125 150 200
E n/a n/a n/a 170 170 180
F (maximum wall thickness) n/a n/a n/a 370 370 385
G 225 253 355 235 235 375
Balanced flue wall outlet (type C12) eliminates expensive roof opening and flashing
Balanced flue roof outlet (type C32)
A
D
B
G
A
E
C
F
D
B
G
Heater positions and flue arrangements are indicative. For heater and flue clearances please refer to our sales leaflets.
Separate combustion air and flue pipes (type C12) for applications where wall thickness exceeds maximum length shown in flue dimension table
Combustion air through wall, flue outlet through the roof (C52)
47
Flue systems..................................................................................................
..................................................................................................
BENSON
Single Wall Stainless Steel Flue PipeGrade 304 stainless steel, for use on gas and oil fired cabinet heaters and oil fired unit
heaters
Flue diameter Ø mm
125 150 175 200 225 250
Starter Kit (1 x universal cowl, 1 x 1m pipe, 1 x 1m changeover section, 1 x storm collar, 1 x flexible flashing kit)
Part No.
List Price £SWFK125
212.00SWFK150
227.00SWFK175
247.00SWFK200
264.00SWFK225
319.00SWFK250
333.00
500mm flue pipePart No.
List Price £33-51-201
23.0033-51-301
25.0033-51-401
27.0033-51-501
28.0033-51-601
31.0033-51-701
34.00
1m flue pipePart No.
List Price £33-51-202
35.0033-51-302
37.0033-51-402
39.0033-51-502
46.0033-51-602
48.0033-51-702
53.00
1m changeover sectionPart No.
List Price £33-51-205
44.0033-51-305
45.0033-51-405
47.0033-51-505
51.0033-51-605
59.0033-51-705
65.00
Elbow 45°Part No.
List Price £33-51-208
23.0033-51-308
24.0033-51-408
26.0033-51-508
28.0033-51-608
29.0033-51-708
34.00
Elbow 90°Part No.
List Price £33-51-209
31.0033-51-309
33.0033-51-409
34.0033-51-509
36.0033-51-609
38.0033-51-709
40.00
90° tee (condensate)Part No.
List Price £33-51-207
47.0033-51-307
49.0033-51-407
52.0033-51-507
56.0033-51-607
57.0033-51-707
60.00
135° tee (condensate)Part No.
List Price £33-51-206
53.0033-51-306
54.0033-51-406
55.0033-51-506
61.0033-51-606
65.0033-51-706
78.00
Adjustable roof platePart No.
List Price £33-51-210
43.0033-51-310
43.0033-51-410
44.0033-51-510
45.0033-51-610
47.0033-51-710
50.00
Storm collarPart No.
List Price £33-51-211
20.0033-51-311
22.0033-51-411
22.0033-51-511
23.0033-51-611
25.0033-51-711
27.00
Standard cowlPart No.
List Price £33-51-214
41.0033-51-314
44.0033-51-414
49.0033-51-514
51.0033-51-614
54.0033-51-714
64.00
Universal terminal Part No.
List Price £33-51-215
71.0033-51-315
81.0033-51-415
85.0033-51-515
90.0033-51-615
97.0033-51-715
98.00
Wall bracketPart No.
List Price £33-51-216
12.0033-51-316
13.0033-51-416
13.0033-51-516
14.0033-51-616
15.0033-51-716
17.00
Joint clamp bandPart No.
List Price £33-51-217
12.0033-51-317
14.0033-51-417
14.0033-51-517
16.0033-51-617
16.0033-51-717
17.00
High temperature flexible flashing c/w fix kitPart No.
List Price £B-RFK-4
43.00B-RFK-4
43.00B-RFK-6
54.007700H-2
54.00B-RFK-7
90.00B-RFK-7
90.00
High temperature flexible flashing with fixing kit for deep profile corrugated sheets
Part No.
List Price £B-RFK-4
43.00B-RFK-6
54.00B-RFK-6
54.00B-RFK-7
90.00B-RFK-7
90.00B-RFK-8
105.00
48
..................................................................................................
..................................................................................................Flue systems
BENSON
Environmental issues dictate that buildings need to operate as effectively and efficiently as possible.
AmbiRad has introduced SmartCom3, the intelligent energy management controller, in order tosatisfy the growing need for higher efficiencies and to complement the development of efficient heating systems.
Simple to program and operate, SmartCom3 provides cost-effective energy management for small single heater installations through to large multi-zone applications requiring centralised control.
Features and Benefits > Easy to program multi-key entry and
on screen prompts
> Suitable for controlling heating and or cooling
> Reduced installation time – units can
be networked via screened cable
> Integral warm air temperature sensor
> Optional remote air sensor, remote
black bulb sensor, duct sensor or outdoor sensor
> Alphanumeric backlit display with
angled screen for easy viewing
> Remote burner lock out facility
> Easy-set overtime and holiday periods
> Hours run metering and service data logging
> Compact IP30 enclosure complete with top or bottom cable entry
> Security – optional passwords prevent unauthorised access to unit
> Dual temperature settings for sports/
non- sports comfort heating
SmartCom Energy Saving ControllerPart number Description List Price £
B-SC3-SZB SmartCom single zone controllerStandard functions include single stage heating/cooling, self adapting optimised start, volt free BMS override, clock enabled relay, additional modes or operation, frost protection and night setback, lockout modes additional external inputs and optimum start (to control 1 heater)
232.00
B-SC3-MZB SmartCom multi-zone controllerAll the functions as 'single zone controller' plus, the ability to communicate with other SmartCom3 controllers, thereby enabling centralised control of multiple zones.
325.00
29-01-218 SmartCom duct air sensor 51.00
29-01-219 SmartCom remote air sensor 51.00
FunctionsSuitable for use with both standard radiant tube and warm air heaters together
with ducted installations. > Self adapting optimised start
> Volt free remote on/off
> Single stage heating/cooling
> Ability to communicate with up to 15 slave units which may be centrally controlled by one master control
(SmartCom3 multi-zone only)
> High / low heat (two stage heating warm
air only
> Three stage cooling or ventilation
> Fully modulating heating and cooling
> Clock update, temperature functions and
program settings
> Zonal lock out indication and reset
functions
> Multi-zone or split zone (radiant applications)
Energy Saving Controller....................................................................................................................................................
....................................................................................................................................................
SmartCom
49
DS High Velocity Destratification FansModel Primary Airflow
m3/hMounting Height
Range mDS Fan
List Price £DS Frost Protection
Fan List Price £
DS 3 3000 4 - 8 347.00 347.00
DS 4 4250 6 - 12 493.00 493.00
DS 6 6500 6 - 12 503.00 503.00
DS 8 7650 10 - 18 532.00 532.00
DS 10 11000 10 - 18 621.00 621.00
DS Optional EquipmentModel Part No DS3
List Price £
DS4List Price
£
DS6List Price
£
DS8List Price
£
DS10List Price
£
Stainless steel wire roof fixing kit 28-00-301 72.40 72.40 72.40 72.40 72.40
Impellor Low Velocity Destratification Fans IMPart No Max
Primary Airflow m3/h
Mounting Height
m
Typical Floor Coverage
m2
List Price £
B-IM1400-C 12000 4 - 16 130 94.90
Impellor Optional EquipmentModel Part No List Price £
Controller for 1 - 5 fans B-IMC5 55.10
Controller for 1 - 12 fans B-IMC12 114.00
These quiet but powerful fans gently propel the warm air down into the working zone. The displacement of this pool of warm air from the roof void to low level has a positive impact in the reduction of fuel usage which, depending upon building height, can be as much as 15%.
Design Data
Select the fan unit to suit the mounting
height requirements. Ideally the fan should
be mounted above the lighting system
and with a clearance of at least 750mm
between the blades and the roof. The
minimum height should take account any
obstruction and the safety of personnel.
The minimum recommended mounting
height is 2.5m.
Calculate the buildings floor area in square
metres, then divide the result by the floor
area coverage for the fan size selected.
Bear in mind that the floor area coverage is
based on maximum mounting height and
this reduces if the fans are mounted lower.
Check the maximum distance between fans
and the minimum clearance from the walls.
....................................................................................................................................................Destratification Fans
Benson destratification fans reverse the natural convection process, re-circulating warm air back to working level providing a permanent reduction in roof space temperature and uniform temperature at floor level.
Model Range
DS fans are available in five sizes, with
mounting heights ranging from 4m to 18m
and air volumes 3000 m3/h to 11000 m3/h.
All units are supplied with a four-way
discharge for improved air distribution.
Design Data
Select the DS unit to suit the mounting
height required, ideally the units should be
installed approximately 1 metre below the
apex.
Calculate the volume of the building and
multiply by two to determine the amount of
air that needs to be re-circulated for
effective de-stratification. Divide by the
primary air flow of the unit to determine the
number of units required.
50
..................................................................................................
..................................................................................................Destratification fans
BENSON
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
Combined Heating and VentilationDV / DH 52 - 53
DF / IDF 54 - 55
Air Rotation 56 - 57
ColdAIR 58
.....................................................................................................................................................
.....................................................................................................................................................
NORDAIRNICHE
51
The Nordair Niche DV/DH direct fired units are designed as make-up air units to provide a heated supply of fresh air for buildings having extract ventilation. They may also be used as high efficiency space heaters for applications requiring ventilation. In summer the units can be used for 'free cooling' ventilation.
Units are available for indoor applications as DV vertical models or DH horizontal models. By combining 100% thermal efficiency (based on net CV) and fully modulating burner control the units accurately match the building heat requirements without loss of burner efficiency thereby minimising energy consumption.
Model Range
The DV/DH Series direct gas fired make-up
air units are available with a choice of six
models within six heat outputs ranging from
67kW to 395kW and airflow from 43203/h
to 25920m3/h.
Discharge Options
To meet the demands of ducted systems
double inlet forward curved fans complete
with 3phase TEFV motors and vee belt
drives are fitted, motors are slide rail
mounted for belt adjustment.
Standard units are designed for ducted
applications up to 125Pa, for higher static
pressure alternative drives and motors may
be specified up to 250Pa.
Units are supplied with a 0-10V duct
temperature sensor to control burner
modulation.
Features & BenefitsFeatures:
> Airflows from 4320m3/h to 25920m3/h
> Net thermal efficiency of 100%
> High burner turndown ratio
> Precise temperature control
> Horizontal or vertical units
> Optional EU4 filters
> Optional air intake cowl incorporating
a bird mesh guard
Benefits: > Simple installation
> High efficiency
> Reduced running costs
> CE approved units
> Simple “user friendly” controls
Direct Fired Heating & Ventilation Units....................................................................................................................................................
....................................................................................................................................................
DV / DH
52
Vertical Freeblowing Direct Gas Fired HeatersModel Heat
Input kWHeat
Output kWAirflow m3/h
List Price £
DV2 75 75 67 4320 5230.00
DV2 150 150 135 8640 5770.00
DV4 225 225 203 12960 7046.00
DV4 300 300 270 16200 8204.00
DV7 375 375 338 21600 11203.00
DV7 450 450 395 25920 12303.00
Horizontal Freeblowing Direct Gas Fired HeatersModel Heat
Input kWHeat
Output kWAirflow m3/h
List Price £
DH2 75 75 67 4320 5462.00
DH2 150 150 135 8640 6010.00
DH4 225 225 203 12960 7426.00
DH4 300 300 270 16200 8608.00
DH7 375 375 338 21600 11772.00
DH7 450 450 395 25920 13203.00
Horizontal Duct Outlet Direct Gas Fired HeatersModel Heat
Input kWHeat
Output kWAirflow m3/h
List Price £
DH2 75D 75 67 4320 5359.00
DH2 150D 150 135 8640 5909.00
DH4 225D 225 203 12960 7219.00
DH4 300D 300 270 16200 8403.00
DH7 375D 375 338 21600 11465.00
DH7 450D 450 395 25920 12594.00
DV/DH Optional EquipmentModel DV / DH 2
List Price £DV / DH 4 List Price £
DV / DH7 List Price £
Inlet mesh 94.40 146.00 198.00
Inlet filters 597.00 775.00 955.00
Factory fitted gas valve complete with union std std std
SmartCom MZ Control std std std
Vertical Duct Outlet Direct Gas Fired HeatersModel Heat
Input kWHeat
Output kWAirflow m3/h
List Price £
DV2 75D 75 67 4320 5130.00
DV2 150D 150 135 8640 5668.00
DV4 225D 225 203 12960 6844.00
DV4 300D 300 270 16200 8003.00
DV7 375D 375 338 21600 10904.00
DV7 450D 450 395 25920 12000.00
53
Direct fired heating and ventilation units..................................................................................................
..................................................................................................
NORDAIRNICHE
The comprehensive range of gas fired air heaters provides high efficiency combined heating and ventilation solutions across a broad spectrum of industrial and commercial applications. Combined heating and ventilation units ensure precise control, excellent indoor air quality and optimum energy efficiency.
The units are available as either direct fired units or indirect fired units to give complete flexibility for optimum design capability.Both the direct fired and indirect fired range of units are fully CE approved and a comprehensive range of optional equipment can be added to the standard models to allow systems to be tailored to meet the requirements for factories, warehouses and other types of large open space buildings.
Model Range
> Indirect gas fired units 150kW-900kW
> Indirect gas fired condensing heaters
> Direct gas fired units 30kW-1200kW
> Airflow range 0.5m³/s to 25m³/s
> External static pressures up to 2000
pascals depending on airflow
> Horizontal Units
> Vertical Units
> Indoor models or fully weatherproofed
outdoor units
> Variable supply air volume with
inverter drives
> Panel and/or bag filters
> Mixing box c/w dampers and optional
actuators
> Integral silencer section
> Optional evaporative cooling module
> Heat recovery
> Air distribution heads
Features & Benefits > CE approved units
> Indoor and outdoor models
> High thermal efficiency for reduced
operating costs
> Fully compatible for use with
transpired solar panels to facilitate use
of renewable solar energy
> Units are supplied fully wired and
complete with controls
> Close temperature control
> Fully modulating direct gas fired
burner control with 20:1 turn down
ratio
> Indirect fired units with turn down
ratio of up to 12:1
Gas Fired Combined Heating & Ventilation....................................................................................................................................................
....................................................................................................................................................
DF / IDF
54
Please contact 01384 489 700
for more information and to
obtain current prices
£P.O.A
DF/MUA
Constant volume direct fired make up air
heaters to provide a fixed rate of heated
fresh air to the space.
The units are ideal for supplying heating
and make up air to large areas or to
individual spray booths etc where
constant extract rates are used.
Generally units are sized to introduce
slightly more make up air into the space
than the extract air volume. A balanced
amount of make up air can provide a slight
positive pressure to uniformly distribute the
air throughout the building and eliminate
random air infiltration.
For special applications such as kitchen
make up air and certain industrial
processes where the transfer of odours or
dust etc to surrounding areas needs to be
avoided the volume of make up air supplied
is lower than the extract rate.
DF/VAV
The variable air volume models allow the
volume of heated make up air to vary to suit
the changing requirements of the building
or changing exhaust rates.
The units are fitted with a special box
burner system c/w integral fan(s) to ensure
optimum combustion throughout the range
of varying volume main air supply.
The units supply 100% fresh air at all times
but the volume of fresh air is automatically
adjusted either by the application of a
building pressure sensor or temperature
sensors.
The building pressure sensor can be set to
maintain a slight positive or slightly
negative pressure inside the building to suit
the requirements of the application.
DF/REC
Nordair Niche variable air recirculation
models are fully CE approved and
patented to provide a constant air volume
with up to 80% recirculation air.
The variable air recirculation option
combines a constant supply of 20% fresh
air which passes over the burner with the
remaining air volume being either fresh air,
recirculation air or a mixture of fresh and
recirculated air.
The variable percentage of fresh air and
recirculation air is accurately controlled via
a fully modulating face and by pass damper
with fresh air introduced using the burner
section and recirculation air via an integral
by pass.
The fully modulating burner control and
modulating damper control functions are
fully Integrated via a microprocessor control
to completely co-ordinate the heating and
ventilation functions.
Kitchen Units
Nordair Niche kitchen units are designed to be installed to provide
tempered and filtered fresh air make-up into commercial kitchens.
The units are of fully insulated weatherproof construction suitable
for external installation and comprise the following options :
> Optional air intake cowl incorporating a bird mesh guard
> Filter section with disposable F6 filters
> High efficiency direct gas fired air burner, complete with
integral combustion air fans and burner turndown of up to
25:1
> Forward curved centrifugal fan
> Standard units provide a maximum of 200Pa ESP, for higher
static pressures consult Nordair Niche
> VAV units are supplied complete with inverter drive and
Nordair Niche box burner
Swimming Pool Units
Nordair Niche swimming pool units are designed to be installed to
provide tempered and filtered fresh air make-up into swimming halls.
The units are of fully insulated weatherproof construction suitable for
external installation and comprise the following options :
> Aluminium frame insulated infill panels
> Supply and extract filter section with disposable F6 filters
> 100% efficiency direct gas fired burner, complete with integral
combustion air fans
> Burner turndown of up to 20:1
> Forward curved centrifugal fan
> Standard units provide a maximum of 250Pa ESP, for higher
static pressures consult Nordair Niche box burner
...............................................................................................................................................................................................................................................................
55
0 - 80%
Gas fired combined heating & ventilation..................................................................................................
..................................................................................................
NORDAIRNICHE
Air rotation units are ideal for applications such as distribution centres and warehouses requiring frost protection or constant background temperatures.
The system provides even heating over large areas and eliminates the requirement for ductwork or de-stratification fans.
Simple fast track installation provides an economic and efficient solution with low ongoing maintenance costs.
Options
> Gas, propane, oil and LPHW fuel types
available
> Internal and external units
> External units fully weatherproofed
and complete with insulated panels
> Balanced flue with combustion air fan
located externally
> Controls upgrade to trend IQ3 Excite
> Fresh air and recirculation options
> Bespoke non-standard heights to suit
application if required
> De-stratification only units also
available
Features & Benefits > Large areas heated by a single unit so
that number of units is reduced to a
minimum
> Fewer units, all sited at low level
reduces ongoing maintenance costs
> No requirement for high level
de-stratification fans
> No requirement for costly ductwork
installation
> Higher thermal efficiency for reduced
running costs
> Heat outputs up to 600kW from single
unit
> High burner turndown ratio for closer
temperature control
> Units may be flued via simple wall
outlets
> Enhanced reliability with multi-try
ignition, and dual heat exchangers
and fans
Gas Fired Combined Heating & Ventilation....................................................................................................................................................
....................................................................................................................................................
Air Rotation
56
Please contact 01384 489 700
for more information and to
obtain current prices
£P.O.A
The Stratification Problem
Hot air, which is less dense and therefore
lighter than cold air, will rise while cold air
tends to fall. This fundamental law of
physics has a negative effect on
conventional air heating systems where the
discharge air temperature is often around
45-50 °C. As a result the discharge air does
not easily mix with the air in the building
and instead tends to rise to high level.
Cold air entering at floor level accelerates
the migration of warm air to the top of the
building and increases the temperature
gradient between the floor and the roof
level.
This layer of cold air forms at low level
making it increasingly difficult to maintain
the required temperature, resulting in cold
zones around the building.
To overcome this problem it is necessary
to install either a large number of high level
de-stratification fans in conjunction with
conventional heaters or an extensive
amount of ductwork to achieve even
temperature distribution and to re-cycle hot
air back down to floor level.
The Air Rotation Solution
Air Rotation provides a simple cost effective
solution by utilising a much greater supply
air volume with only a low temperature
rise.
The system draws in the cooler air at low
level and rotates the air to high level where
it mixes with the warmer air. This develops
a gentle airflow pattern, displacing the high
level hot air and returning it to floor level to
provide automatic de-stratification.
When additional heat is required the supply
air is tempered to give a minimal
temperature difference between air
discharge and the space temperature so
that the natural tendency of the hot air to
stratify is virtually eliminated. The
rotation of large air volumes of tempered
air provides even wall to wall and floor to
roof temperature distribution and allows
heat gains from lighting and other
sources to be re-circulated to low level to
reduce energy consumption.
The units have a turndown ratio of 4:1 to
ensure that the optimum amount of heat
can be supplied to meet changing
building requirements.
An integral control system monitors the
temperature at high and low level within
the building and adjusts the discharge
temperature to maintain optimum heat
distribution.
The fan assisted flues from the unit can be
terminated through either the roof or wall.
The simple wall terminal eliminates the
requirement for costly flue systems in tall
buildings and associated roof penetrations.
Technical DataModel Type Heat Output
kWNatural Gas Rate
(G20)m3/h
Airflowm3/s
Motor SizekW
IDF5 IDF5-50 V -100V 50-100 5.92 - 11.45 5m3/s Single 3kW Motor
IDF8 IDF8-75 V -150 V 75-150 8.73 - 17.44 8m3/s Single 4kW Motor
IDF10 IDF10-100 V -200 V 100-200 11.45 - 23.28 10m3/s Single 5.5kW Motor
IDF13 IDF13-100 V -250 V 100-250 11.84 - 29.26 13m3/s Twin 4kW Motor
IDF16 IDF16-150 V -300 V 150-300 17.46 - 34.88 16m3/s Twin 4kW Motor
IDF21 IDF21-200 V -400 V 200-400 22.90 - 46.56 21m3/s Twin 7.5kW Motor
IDF27 IDF27-300 V -500 V 300-500 34.88 - 58.52 27m3/s Twin 11kW Motor
IDF32 IDF32-350 V -600 V 350-600 40.38 - 69.76 32m3/s Twin 11kW Motor
57
Gas fired combined heating & ventilation..................................................................................................
..................................................................................................
NORDAIRNICHE
ColdAIR evaporative cooling systems are fast becoming the standard way to cool industrial and commercial premises, by drawing air through continually wetted pads that surround the unit. The evaporation of the moisture into the air reduces its temperature, whilst the process also filters it, removing airborne contaminants.
Evaporative cooling systems are designed with energy efficiency in mind, typically consuming only 20% of the energy used by traditional air conditioning systems and with the ability to install without any structural alterations to your existing building.
ColdAIR Evaporative cooling systemModel Installation Airflow
m3/hEquivalent Refrigerating
Capacity kWIncludes List price £
WA100WA150
Wall/windowWall/window
1000013000
1519
Electronic controller and wall bracket
2425.002545.00
RA150RA200
Roof TopRoof Top
1300020000
1930
Electronic controller and base stand
2770.003692.00
RC100RC200
Roof Top (centrifugal)Roof Top (centrifugal)
1000019000
1530
Electronic controller and base stand
3925.004686.00
ColdAIR Optional EquipmentModel WA100
List price £WA150
List price £RA150
List price £RA200
List price £RC100
List price £RC200
List price £
Horizontal and vertical air diffuser with adjustable flaps 600 x 600 (P/N C101.942)
235.00 235.00 235.00 - 235.00 -
Horizontal and vertical air diffuser with adjustable flaps 1150 x 600 (P/N C101.943)
- - - 377.00 - 377.00
Roof air diffuser 4 way with horizontal adjustable flaps (P/N C103.153) 636.00 636.00 636.00 - 636.00 -
Roof air diffuser 6 way with horizontal adjustable flaps (P/N C103.158) - - - 1164.00 - 1164.00
Winter hood (P/N C104.106) 102.00 102.00 - - - -
Winter hood (P/N C104.122) - - 125.00 - 125.00 -
Winter hood (P/N C104.123) - - - 156.00 - 156.00
Network router (P/N MAC600.008) 354.00 354.00 354.00 354.00 354.00 354.00
Wall/Windowmodel WA
Roof Topmodel RA
4 way diffuserbox
Evaporative Cooling System....................................................................................................................................................
....................................................................................................................................................
FeaturesFeatures:
> Consumes 80% less energy than
conventional air conditioning systems
> Door and windows can be left open with
no loss in efficiency
> 100% fresh filtered air
> Low Installation, operating and
maintenance costs
> Low energy consumption
> No refrigerant chemicals, no
environmental damage
> Improvement of the working conditions
> increase productivity
> Spot cooling capability
> Wall / window / roof mounting
> Possibility to only ventilate in the coole
seasons
ColdAIR
58
..................................................................................................
..................................................................................................
NORDAIRNICHEEvaporative cooling system
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
Air CurtainsAC 62 - 64
AC Chassis 65
ACR 66 - 67
AC & ACR Mini 68
ACT 69
SmartElec 70
Options 71
AB 72 - 73
..................................................................................................
..................................................................................................
AIRBLOC
59
Warehouses, factories, retail premises and cold rooms are all subject to the problems caused by frequently opened doors. The open door not only causes discomfort but greatly increases energy loss and, therefore, the running costs of the building. Airbloc units offer a cost-effective, energy efficient solution to these problems by reducing heat loss by 80%.
The Airbloc rangecomprises ambient unheated models or heated models using gas, electricity, hot water or steam. In well insulated structures, Airbloc provides the final complement to the low energy concept by eliminating a major source of heat-loss.
Simple Versatile Installation
Airbloc units are supplied in a compact
modular format for simplified on-site
handling. Units are designed for doors up to
six metres high. For industrial applications
where over-door installation is not practical,
the units may be vertically mounted at one
or both sides of the door. Remote control
panels are provided with each air curtain to
reduce on-site wiring.
Food Safety
European Food Safety Inspection Service
(EFSIS) advises that where food is handled
or stored, doors should be adequately
proofed. When doors have to be opened,
Airbloc air curtains offer a suitable barrier to
stop the ingress of dust and flying insects,
protecting the internal environment. The
use of an air curtain across cold store
doors also helps prevent the icing of floors
and condensers.
Special OrdersPlease note we try our very best to meet
clients requested delivery dates, however
the following units or options require a lead
time of 1 week or more:
> Silver AC units
> Chassis recessed units
> 4 or more LPHW units
> Exit signs
> RAL colour coding
For accurate lead times please call: 01384 489 708
Commercial & Industrial Air Curtains....................................................................................................................................................
....................................................................................................................................................
Air Curtains
60
Product Portfolio:
Control OptionsAll units (except mini AC600SE3) are
supplied as standard with a wired remote
control panel to adjust fan speed and heat
output. The wired remote panel can be
sited at a location to suit the user up to
100m from the air curtain.
Airbloc SmartElec energy saving control
panels are available for use with all Airbloc
AC and ACR three phase electrically heated
units. SmartElec is simple to install and
operate and does not require on-site
specialist commissioning. More importantly
it reduces power consumption and energy
costs of running the air curtain by up to
50%.
Commercial / retail air curtains
Airbloc air curtains can be recess mounted in
bulkheads or above false ceilings and can be
fully cased for surface mounting, offering
exceptional installation flexibility.
Ceiling tile heaters
Designed to complement the Airbloc air
curtain range, ceiling tile heaters provide
a cost-effective heating solution for retail
outlets, restaurants and showrooms.
Available recessed or surface mounted.
Industrial air curtains
Designed for industrial or large warehousing
doors, the powerful Airbloc AB range of
industrial air curtains offers protection for
doorways up to six metres high. Industrial
units are available as gas, low pressure hot
water (LPHW), medium pressure hot water
(MPHW), electric or steam heated.
Wired remote control panel
Airbloc SmartElec control panel
61
The Airbloc AC Series is a commercial/retail air curtain, designed to be aesthetically pleasing when wall mounted or on drop rods in front of glass fronted entrances.
The unit has a host of unique lighting and building safety features that enhance both its functionality and looks. The semi-circular profile and range of finishes make the air curtains an aesthetic addition to a building’s interior.
Model Range
The AC Series is available in 3 versions:
> Ambient (non-heated)
> Electric .heating
> Low pressure hot water heating
Choice of outputs 4.5, 6, 9, 12, 18 and
24kW (heated models).
White (RAL9010) or metallic silver
(RAL9006) as standard colours.
Alternative colours to order.
Applications
> Bars
> Hotels
> Offices
> Restaurants
> Shops
Features & Benefits > Reduces heat loss around open doors
by up to 80%
> Suitable for mounting heights of three
or four metres depending upon
capacity
> Good aesthetic appearance
> Flush adjustable grilles
> Innovative shape
> Standard or high capacity
> CE approved
> Cost-effective heating solution
> Units can be placed side by side to
resemble a continuous unit
Commercial / Retail Air Curtains....................................................................................................................................................
....................................................................................................................................................
AC Series
62
AC fitted with optional illuminated fire exit sign
....................................................................................................................................................
AmbientModel Door Width
mmDoor Height mm Airflow
m3/hList Price £
AC1000SA 1000 3000 1850 1029.00
AC1500SA 1500 3000 2400 1427.00
AC2000SA 2000 3000 4100 1797.00
Electric 3 PhaseModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
StandardCapacity
AC1000SE4-5 4.5 1000 3000 1850 1076.00
AC1000SE9 9 1000 3000 1850 1076.00
AC1500SE6 6 1500 3000 2400 1476.00
AC1500SE12 12 1500 3000 2400 1476.00
AC2000SE9 9 2000 3000 4100 1846.00
AC2000SE18 18 2000 3000 4100 1846.00
HighCapacity
AC1000HE6 6 1000 4000 2300 1448.00
AC1000HE12 12 1000 4000 2300 1448.00
AC1500HE9 9 1500 4000 3300 2091.00
AC1500HE18 18 1500 4000 3300 2091.00
AC2000HE12 12 2000 4000 5000 2471.00
AC2000HE24 24 2000 4000 5000 2471.00
Electric Single PhaseModel Door Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
AC1000SE6-1PH 1000 3000 1850 1076.00
AC1500SE6-1PH 1500 3000 2400 1476.00
AC2000SE9-1PH 2000 3000 4100 1797.00
*Can also be supplied with Exit Sign
Ambient
Electric 3 Phase + Exit SignModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
StandardCapacity
AC1000SE9-EXIT 9 1000 3000 1850 1264.00
AC1500SE12-EXIT 12 1500 3000 2400 1664.00
AC2000SE18-EXIT 18 2000 3000 4100 2035.00
HighCapacity
AC1000HE12-EXIT 12 1000 4000 2300 1637.00
AC1500HE18-EXIT 18 1500 4000 3300 2279.00
AC2000HE24-EXIT 24 2000 4000 5000 2660.00
Electric single phase
Electric
Electric + Exit Sign
Commercial/retail air curtains..................................................................................................
..................................................................................................
AIRBLOC
63
LPHWModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
StandardCapacity
AC1000SW9 9 1000 3000 1850 1128.00
AC1500SW12 12 1500 3000 2400 1528.00
AC2000SW18 18 2000 3000 4100 1897.00
HighCapacity
AC1000HW12 12 1000 4000 2300 1500.00
AC1500HW18 18 1500 4000 3300 2143.00
AC2000HW24 24 2000 4000 5000 2523.00
LPHW + Exit SignModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
StandardCapacity
AC1000SW9-EXIT 9 1000 3000 1850 1317.00
AC1500SW12-EXIT 12 1500 3000 2400 1716.00
AC2000SW18-EXIT 18 2000 3000 4100 2085.00
HighCapacity
AC1000HW12-EXIT 12 1000 4000 2300 1637.00
AC1500HW18-EXIT 18 1500 4000 3300 2279.00
AC2000HW24-EXIT 24 2000 4000 5000 2712.00
Electric 3 Phase + SmartElec ControllerModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
StandardCapacity
AC1000SE9-SM 9 1000 3000 1850 1704.00
AC1500SE12-SM 12 1500 3000 2400 2104.00
AC2000SE18-SM 18 2000 3000 4100 2523.00
HighCapacity
AC1000HE12-SM 12 1000 4000 2300 2149.00
AC1500HE18-SM 18 1500 4000 3300 2768.00
AC2000HE24-SM 24 2000 4000 5000 3202.00
Electric 3 Phase + SmartElec Controller + Exit SignModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
StandardCapacity
AC1000SE9-SM-EXIT 9 1000 3000 1850 1892.00
AC1500SE12-SM-EXIT 12 1500 3000 2400 2292.00
AC2000SE18-SM-EXIT 18 2000 3000 4100 2663.00
HighCapacity
AC1000HE12-SM-EXIT 12 1000 4000 2300 2337.00
AC1500HE18-SM-EXIT 18 1500 4000 3300 2907.00
AC2000HE24-SM-EXIT 24 2000 4000 5000 3288.00
Electric + SmartElec Control
Electric + SmartElec Control + Exit Sign
LPHW
LPHW + Exit Sign
..................................................................................................
..................................................................................................
AIRBLOCCommercial/retail air curtains
64
The Airbloc AC chassis recessed series is a commercial/retail air curtain.
Designed for discreet positioning in suspended ceiling or bulkhead in doorways of retail or commercial premises.
It creates comfortable conditions for staff and customers, by providing a powerful down-flow of heated or ambient air.
....................................................................................................................................................Commercial / Retail Air Curtains....................................................................................................................................................AC Chassis Series
Commercial/retail air curtains..................................................................................................
..................................................................................................
AIRBLOC
AmbientModel Door Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
AC1000SA-CMS 1000 3000 1850 1029.00
AC1500SA-CMS 1500 3000 2400 1427.00
AC2000SA-CMS 2000 3000 4100 1797.00
Electric Single PhaseModel Door Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
AC1000SE6-1PH-CMS 1000 3000 1850 1076.00
AC1500SE6-1PH-CMS 1500 3000 2400 1476.00
AC2000SE9-1PH-CMS 2000 3000 4100 1846.00
Electric 3 PhaseModel Heat
Input kW
Door Widthmm
Door Height
mm
Airflow m3/h
List Price £ List Price with
SmartElec £
Standard Capacity
AC1000SE9-CMS 9 1000 3000 1850 1076.00 1704.00
AC1500SE12-CMS 12 1500 3000 2400 1476.00 2104.00
AC2000SE18-CMS 18 2000 3000 4100 1846.00 2523.00
High Capacity
AC1000HE12-CMS 12 1000 4000 2300 1448.00 2149.00
AC1500HE18-CMS 18 1500 4000 3300 2091.00 2768.00
AC2000HE24-CMS 24 2000 4000 5000 2471.00 3202.00
Ambient
Electric Single Phase
Electric
LPHWModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
AC1000SW9-CMS 9 1000 3000 1850 1128.00
AC1500SW12-CMS 12 1500 3000 2400 1528.00
AC2000SW18-CMS 18 2000 3000 4100 1897.00
High Capacity
AC1000HW12-CMS 12 1000 4000 2300 1500.00
AC1500HW18-CMS 18 1500 4000 3300 2143.00
AC2000HW24-CMS 24 2000 4000 5000 2523.00
LPHW
65
The Airbloc ACR Series recessed cased air curtain is designed for discreet positioning in a suspended ceiling or bulkhead in the doorways of retail or commercial premises, It creates comfortable conditions for staff and customers by providing a powerful down-flow of heated or ambient air.
Model Range
The ACR Series is available in 3 versions:
> Ambient (non-heated)
> Electric heating
> Low pressure hot water heating
Choice of outputs 6, 9, 12, and 18kW
(heated models).
White (RAL9010) as standard.
Alternative colours to order.
Applications
> Bars
> Hotels
> Offices
> Restaurants
> Shops
Features & Benefits > Suitable for mounting heights of three
or four metres dependent upon
capacity
> Available in four sizes - 1.2m, 1.5m,
1.8m and 2m
> Prevents heated or conditioned air
escaping through open doors
> Only 200mm or 220mm deep -
shallowest of its type on the market.
This maximises internal space by
reducing the required depth of the
suspended ceiling into which it is
recessed
> Optional side skirt for doorways with
restricted space and no suspended
ceiling or bulkhead
> Maximum output velocity of 8.4m/sec
on standard capacity models and 11m/
sec for high capacity models
Commercial / Retail Air Curtains....................................................................................................................................................
....................................................................................................................................................
ACR Series
66
LPHWModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
ACR100SW9 9 1200 3000 1646 1336.00
ACR150SW12 12 1500 3000 2085 1933.00
ACR200SW18 18 2000 3000 2851 2298.00
High Capacity
ACR120HW12 12 1000 4000 3300 1581.00
ACR180HW18 18 1500 4000 5000 2298.00
Electric 3 Phase + SmartElec ControllerModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
ACR100SE9-SM 9 1000 3000 1646 2015.00
ACR150SE12-SM 12 1500 3000 2085 2697.00
ACR200SE9-SM 9 2000 3000 2851 3071.00
ACR200SE18-SM 18 2000 3000 2851 3071.00
High Capacity
ACR120HE12-SM 12 1000 4000 3300 2320.00
ACR180HE9-SM 9 1500 4000 5000 3071.00
ACR180HE18-SM 18 1500 4000 5000 3071.00
Electric Three PhaseModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
ACR100SE4-5 4.5 1000 3000 1646 1406.00
ACR100SE9 9 1000 3000 1646 1406.00
ACR150SE6 6 1500 3000 2085 2040.00
ACR150SE12 12 1500 3000 2085 2040.00
ACR200SE9 9 2000 3000 2851 2414.00
ACR200SE18 18 2000 3000 2851 2414.00
High Capacity
ACR120HE6 6 1000 4000 3300 1663.00
ACR120HE12 12 1000 4000 3300 1663.00
ACR180HE9 9 1500 4000 5000 2413.00
ACR180HE18 18 1500 4000 5000 2413.00
Electric Single PhaseModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
ACR100SE3-1PH 4.5 1000 3000 1646 1406.00
ACR100SE6-1PH 9 1000 3000 1646 1406.00
ACR150SE6-1PH 12 1500 3000 2085 2040.00
ACR200SE9-1PH 8 2000 3000 2851 2414.00
Ambient
Electric Single Phase
Electric
Electric + SmartElec Control
LPHW
Commercial/retail air curtains..................................................................................................
..................................................................................................
AIRBLOC
67
AmbientModel Door Width
mmDoor Height
mmAirflow m3/h
List Price £
Standard Capacity
ACR100SA 1000 3000 1646 1285.00
ACR150SA 1500 3000 2085 1890.00
ACR200SA 2000 3000 2854 2191.00
High Capacity
ACR120HA 1000 4000 3300 1521.00
ACR180HA 1500 4000 5000 2191.00
The Airbloc AC Mini Series is an aesthetically pleasing commercial/ retail over door, wall or ceiling mounted heater.
The semi-circular profile makes the over door heater an attractive addition to a building’s interior.
Model Range
Available with heaing capacities of 3kW,
4.5kW or 6kW for maximum door widths of
600mm, 800mm and 1,000mm.
The 3kW model has integral switches; other
models are controlled remotely from wired
switch boxes.
Features & Benefits
> Good aesthetic appearance
> Swivel brackets can be wall ceiling or
drop rod mounted
> Innovative shape
> CE approved
> Cost-effective heating solution
Applications
> Bars
> Hotels
> Offices
> Restaurants
> Shops
Commercial/Retail Over Door Heater....................................................................................................................................................
....................................................................................................................................................
AC & ACR Mini Series
Electric Single PhaseModel Heat Input
kWDoor Width
mmDoor Height
mmAirflow m3/h
List Price £
MINI600SE3 3 600 2300 273 186.00
MINI800SE4-5 4.5 800 2500 382 249.00
MINI1000SE6 6 1000 2500 382 395.00
Electric
Electric Single PhaseModel Heat Input
kWWindow/Door
Widthmm
Door Height mm
Airflow m3/h
List Price £
ACRMINI3 3 600 2300 1646 496.00
ACRMINI4-5 4.5 600 2500 2085 558.00
ACRMINI6 6 900 2500 2851 762.00
Electric
68
The Airbloc ACT Series is an electric heater that directs a down-flow of warm air from overhead, delivering immediate heat where required and rapidly creating a comfortable environment for staff and customers.
The ACT Series is designed to complement the Airbloc air curtain range to provide a cost-effective heating solution.
Model Range
> Surface mounted or recessed to
replace a standard ceiling tile
> Available with three heating capacities
of 3kW, 4.5kW and 6kW
> Available in a white finish with egg
crate grilles to ensure the visual
integrity of the interior retained
Applications
> Restaurants
> Retail outlets
> Showrooms
> Stockrooms (surface mounted)
Features & Benefits
> Maximum mounting heights 3m to
3.5m
> Compact dimensions to fit shallow
ceiling voids
> Immediate warmth
> Quiet operation
> Good aesthetic appearance
Recessed Ceiling Tile & Surface Mounted Stockroom Heaters ....................................................................................................................................................
....................................................................................................................................................
ACT Series
Electric Single Phase - RecessedModel Heat Input
kWDimensions
mmMounting Heights mm List Price £
ACT03R 3 220H x 600W x 600D 3000 386.00
ACT04R 4.5 220H x 600W x 600D 3500 410.00
ACT06R 6 220H x 600W x 600D 3500 450.00
Electric Single Phase - Surface MountedModel Heat Input
kWDimensions
mmMounting Heights
mmList Price £
ACT03S 3 220H x 600W x 600D 3000 485.00
ACT04S 4.5 220H x 600W x 600D 3500 510.00
ACT06S 6 220H x 600W x 600D 3500 549.00
69
The Airbloc SmartElec energy saving control unit reduces both power consumption and energy costs by up to 50%, making it the perfect complement for Airbloc energy saving air curtains.
Suitable for both new and existing installations, SmartElec is packed with features to make life easier for installers and users alike.
SmartElec is suitable for use with Airbloc AC, ACR and ACT 3 phase electrically heated units.
Features
> Simple installation - wiring via a plug
and play cable and connectors are
direct to the controller, no
intermediary terminal blocks are
required
> Easy programming - users merely
select whether they require the heat
on or off, the required fan setting (1,2
or 3 speed), and the outlet
temperature setting
> Ability to be linked with air-
conditioning units via optional relay,
enabling elements to be switched off
when in cooling mode
> For new installation, factory fitted
power units are mounted in the air
curtain and pre-wired to air curtain
components
> Retrospecting fitting - can be fitted
into all Airbloc 3 Phase air curtains or
placed in an enclosure elsewhere and
wired to the air curtain
> BMS compatible via Modbus
communication
> Can be linked to PIR
Benefits
> Energy saving - intelligent controller
monitors set temperatures to ensure
that once reached the unit merely
modulates to maintain temperature
> Cost savings - no specialist
commissioning required
> Reduced payback period on
investment thanks to the significant
energy savings generated
> Easier installation between air curtain
and control panel - via plug and play
24V Belden 8132 cabling (various
lengths available)
> Centralised control - units an be
mounted up to 100m from the air
curtain
> Enhanced security - all units can be
security coded to prevent
unauthorised access
> Interlink and independent control of
up to 16 air curtains from one control
panel
Energy Saving Controller....................................................................................................................................................
....................................................................................................................................................
SmartElec
70
Additional Options for Airbloc Air Curtains ....................................................................................................................................................
....................................................................................................................................................
Options Please note we try our very best to meet clients requested delivery dates, however the following units or options require a lead time of 1 week
or more:
Silver AC units Chassis recessed units 4 or more LPHW units Exit signs RAL colour coding
For accurate lead times please call: 01384 489 708.
AC / ACR RAL Colour (RAL or BS number required)
Model List Price £
RAL Colour coding 1m stock colour 164.00
RAL Colour coding 1.5m stock colour 219.00
RAL Colour coding 1.8m stock colour 258.00
RAL Colour coding 2m stock colour 273.00
RAL Colour coding 2.5m stock colour 362.00
Plug and Play CableModel List Price £
SE2-CABLE-2 2 Metres 15.80
SE2-CABLE-10 10 Metres 21.70
SE2-CABLE-20 20 Metres 32.80
SE2-CABLE-30 30 Metres 42.60
SE2-CABLE-50 50 Metres 60.90
SE2-CABLE-100 100 Metres 166.00
SC-0S Outside Sensor 51.98
900477 Door Magnet Set 39.20
ACR Side SkirtsModel List Price £
102701 Side skirt to fit ACR 100 75.40
106249 Side skirt to fit ACR 120 78.20
103150 Side skirt to fit ACR 150 95.20
106251 Side skirt to fit ACR 180 115.00
106249 Side skirt to fit ACR 200 115.00
> > > > >
71
Commercial/retail air curtains..................................................................................................
..................................................................................................
AIRBLOC
AccessoriesPart No List Price £
6100 Graslin Time Clock 141.10
6533 Drop Rods (M12 x 3 meters) 7.00
100887 Drop Rod Covers (1.66m) 9.79
AB industrial air curtains provide a barrier of high velocity air that helps block incoming winds and stops warm air escaping. They achieve this by delivering a powerful barrier of heated air across the entire width of the doorway. Units can be easily fitted within existing or new buildings and are ideal for open doorways.
Units are best mounted horizontally above the door to enable high-level warm air to be re-circulated to working level. Where over-door mounting is not possible, alternative units are available which may be mounted vertically at one or both sides of the door.
Model Range > Eight models, for door widths from 2
metres to 6.7 metres
> Suitable for doorways up to six metres
high
> Heat outputs from 24kW to 195kW
> Choice of ambient, gas, electric, LPHW
or steam units
> Units may be specified for either use
on natural gas (G20) or propane (G31)
> Standard units are suitable for horizontal mounting over the top of a door. For applications requiring vertical air curtains special ‘tailor made’ units are available
Features > Lower energy bills; air curtains provide
an effective barrier to minimise the
loss of warm air through open doors
> Complement and improve efficiency of
conventional heating systems
> Allow doors to be left open for fork
lift access
> Heated units can operate when the
door is closed to provide
supplementary heating
> Models are supplied to site in modular
format for ease of handling
> All models are supplied with remote
control panels
> Optional fan speed control is available
on all models
Industrial Air Curtains....................................................................................................................................................
....................................................................................................................................................
AB Air Curtains
72
Ambient (no heating)Model No of
modulesHeat Input (kW) Max Door Height Length List Price £
AB225A 1 n/a 6.0m 2.25m 2721.00
AB350A 2 n/a 6.0m 3.50m 3971.00
AB400A 2 n/a 6.0m 4.00m 4539.00
AB450A 2 n/a 6.0m 4.50m 5001.00
AB525A 3 n/a 6.0m 5.25m 5463.00
AB575A 3 n/a 6.0m 5.75m 5804.00
AB625A 3 n/a 6.0m 6.25m 6135.00
AB675A 3 n/a 6.0m 6.75m 6462.00
Electric HeatedModel No of
modulesHeat Input (kW) Max Door Height Length Temp rise oC List Price £
AB225E 1 24 6.0m 2.25m 7 3362.00
AB350E 2 36 6.0m 3.50m 7 4718.00
AB400E 2 42 6.0m 4.00m 7 4833.00
AB450E 2 48 6.0m 4.50m 7 4938.00
AB525E 3 54 6.0m 5.25m 7 6199.00
AB575E 3 60 6.0m 5.75m 7 6325.00
AB625E 3 66 6.0m 6.25m 7 6902.00
AB675E 3 72 6.0m 6.75m 7 7018.00
Gas HeatedModel No of
modulesHeat Input (kW) Max Door Height Length Temp rise oC List Price £
AB225N 1 65 6.0m 2.25m 16 3929.00
AB350N 2 100 6.0m 3.50m 16 5925.00
AB400N 2 115 6.0m 4.00m 16 6661.00
AB450N 2 130 6.0m 4.50m 16 7060.00
AB525N 3 150 6.0m 5.25m 16 8972.00
AB575N 3 165 6.0m 5.75m 16 9372.00
AB625N 3 180 6.0m 6.25m 16 9792.00
AB675N 3 195 6.0m 6.75m 16 10191.00
73
....................................................................................................................................................
Carriage Charges
74
Warm Air Unit Equipment Quantity
Models 1 2-4 5+
ULTRA (ULSA) 25 - 5075 - 100
107.00 each133.00 each
99.00 each123.00 each
92.50 each114.00 each
UESA 35 - 5583 - 102
107.00 each133.00 each
99.00 each123.00 each
92.50 each114.00 each
Models 1 2-4 5+
UDSA 11 - 7385 - 100
83.50 each109.00 each
78.50 each102.00 each
74.00 each93.50 each
UDSB 15 - 5564
107.00 each133.00 each
99.00 each123.00 each
92.50 each114.00 each
Models 1 2-4 5+
Variante (VRA / VRE) 12 - 6072 - 145
83.50 each109.00 each
78.50 each102.00 each
74.00 each93.50 each
Variante (VRBD / VRC) 12 - 4250 - 6072 - 145
83.50 each 107.00 each133.00 each
78.50 each99.00 each
123.00 each
74.00 each92.50 each
114.00 each
External Variante 12 - 6072 - 145
119.00 each133.00 each
102.00 each123.00 each
92.50 each114.00 each
Models 1 2-4 5+
OUH 30 - 6070 - 100
83.50 each131.00 each
77.50 each126.00 each
61.00 each109.00 each
Models 1 2-4 5+
EnviroAir SDH 25 - 5573 - 100
261.00 each277.00 each
256.00 each273.00 each
251.00 each267.00 each
EnviroAir SHH 55 - 83102
317.00 each333.00 each
312.00 each329.00 each
307.00 each323.00 each
Radiant & Evaporative Cooling EquipmentModels
Vision, Nor-Ray-Vac, RV Plaque, Electric Quartz and Evaporative cooling
All models carriage charge 6% of net invoice(minimum charge £35.00, maximum charge £1200.00 per delivery)
75
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
Destratification Fans Quantity
Models Delivery Options 1 2-4 5+
All models 3-4 daysNext day
34.00 each59.50 each
24.50 each 50.50 each
20.50 each46.50 each
Off-loading is the responsibility of the customer, if you require special off-loading facilities please call the UK sales office on 01384 489 700.
FlueModels
Flue only All flue carriage charge 6% of net invoice (minimum charge £35.00)
Flue shipped with heater orders Free of charge
Carriage Charge Information
> UK mainland only, other destinations P.O.A
> Hiab and other special requirements P.O.A
> All prices ex-works Brierley Hill / Knighton
> All equipment sold subject to Conditions of Sale
> Transport charges are not subject to trade discount
> Carriage charges maybe subject to a fuel surcharge
> All prices based upon 3 day delivery unless specified; next day delivery add £35.00 per unit
> Next day deliveries based on ex-stock units being delivered next working day on orders received before 12.00 noon
Gas / Oil & PV Cabinet Equipment Quantity
Models 1 2 3 - 4 5+
Vertical Units 30 - 8595 - 145
180 - 275350 - 375
170.00 each202.00 each235.00 each
P.O.A
153.00 each180.00 each213.00 each
P.O.A
137.00 each165.00 each192.00 each
P.O.A
P.O.AP.O.AP.O.AP.O.A
Horizontal & Downflow Units 60 - 85120 - 135180 - 275350 - 375
192.00 each245.00 each279.00 each328.00 each
175.00 each224.00 each256.00 each296.00 each
159.00 each208.00 each224.00 each262.00 each
P.O.AP.O.AP.O.AP.O.A
Commercial Air Curtains Quantity
Models Delivery Options 1 2-4 5+
AC, ACRAC / ACR Mini, ACT
Next dayNext day
58.00 each35.00 each
49.00 each 32.00 each
45.00 each29.00 each
All models Next day before 9:00 am 82.00 each 73.00 each 69.00 each
Industrial Air Curtains Quantity
Models No of modules 1 2-4 5+
AB 1 65.00 each 55.00 each 50.00 each
2 105.00 each 89.00 each 80.00 each
3 145.00 each 123.00 each 111.00 each
Terms & ConditionsNo order shall be binding until acknowledged by us in writing . The products covered by this price list are all deemed to be of standard colour,
duty and specification. All prices are ex-works. Carriage will be charged at the rate ruling at date of despatch. Minimum order charge £25.00
plus p&p on small items. VAT will additionally be chargeable at the rate ruling of date of invoice. ..................................................................................................................................................................................................................................................
Payment Terms
30 days from date of invoice for approved accounts. Payment prior to despatch and early payment discounts quoted upon request...................................................................................................................................................................................................................................................
Returns Policy
We hope you will be completely satisfied with any product or component purchased from AmbiRad Group, but if you wish to return an item,
we aim to make it as quick and convenient as possible. ..................................................................................................................................................................................................................................................
Returns Process
Please call 01384 489700 and ask for the relevant department.
UK Sales for heater and accessory returns
Spares for spare part returns
Service for faulty items within warranty
Please have your return details ready and our trained staff will guide you through the process. On acceptance a returns material authorisation
number will be given which must be included both on the packaging and returns paperwork. Upon the issuing of an RMA number, goods
must be returned to us within 10 working days. We are unable to process any goods returned without an RMA number.
Not all requests to return goods will be accepted...................................................................................................................................................................................................................................................
Damaged in Transit
If you take delivery of a product that has been damaged in transit, the goods must be checked and any damage reported in writing within 3
working days. Claims made outside this period will not be considered. The product then requires return/collection within 10 working days...................................................................................................................................................................................................................................................
Return of Faulty Goods
Should a fault develop with a product purchased from us within the first year of ownership, please contact our Service department with details
of the fault and we will advise you how to proceed. AmbiRad Group reserves the right to either replace or repair faulty item(s). Should we
deliver a replacement item we will invoice for it, crediting the faulty item upon receipt...................................................................................................................................................................................................................................................
Ordered Incorrectly/Incorrectly Supplied/Not Required
If an item has either been ordered incorrectly, incorrectly supplied or is not required, it can be returned within 30 days from purchase as long
as it remains unused, in new condition and with all packaging and labels intact. Should AmbiRad Group incur any costs in re-working or
re-packaging the returned items to a re-saleable condition, this will affect the amount of credit due. Returned items that have been ordered
incorrectly or are not required will incur a 25% restocking charge. If these items are collected, a collection charge will also apply. Heaters built
to customer specification will not be eligible for return; any cancellation prior to despatch will be subject to a charge relevant to costs incurred...................................................................................................................................................................................................................................................
Excess Items
AmbiRad Group systems are designed using the information available to us at the time. Due to the high cost of handling and risk of damage,
it is not possible for excess Nor-Ray-Vac, herringbone materials or warm air flue to be returned for credit...................................................................................................................................................................................................................................................
Delivery Dates
All dates quoted for delivery are approximate only and AmbiRad Group shall not be liable for the delay in delivery of goods however caused.
You are advised to ensure that goods have been delivered to the required location before committing labour.
76
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
..........................................................................................................................................................................................................................................................................................................................................................................
Notes
77
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S
..........................................................................................................................................................................................................................................................................................................................................................................
AMBIRAD LIMITED Fens Pool Avenue
Brierley Hill West Midlands DY5 1QA
United Kingdom
Tel: 01384 489 700 Fax: 01384 489 707
[email protected] www.ambirad.co.uk
Doc
umen
t re
fere
nce
num
ber:
GB/
AG
/069
/091
3
AmbiRad UK is a registered trademark of AmbiRad Limited. Because of continuous product innovation, Ambirad reserves the right to change product specification without due notice.
AMBIRAD AIRBLOC NORDAIRNICHE BENSON A Thomas & Betts Company. Registered in England No. 1390934. Registered office: 27/28 East Castle Street, London.
AMBIRADH EAT I NG A N D V EN T I L AT I O N SOLU TION S