principle and application of gc-ms

36
Principle and Application of GC-MS 2012-09-17

Upload: tyrone

Post on 23-Feb-2016

191 views

Category:

Documents


3 download

DESCRIPTION

Principle and Application of GC-MS. 2012-09-17. Content. GC-MS &HPLC-MS Instrument and column Sample preparation Preferences Application in my research. GC-MS &HPLC-MS. Preface Differences . 1.Principle polar VS non-polar 2. Mobile phase liquid VS gas 3. Ionization way - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Principle and Application of  GC-MS

Principle and Application of GC-MS

2012-09-17

Page 2: Principle and Application of  GC-MS

Content

• GC-MS &HPLC-MS• Instrument and column• Sample preparation• Preferences• Application in my research

Page 3: Principle and Application of  GC-MS

GC-MS &HPLC-MS• Preface

• Differences

1.Principle polar VS non-polar 2. Mobile phase liquid VS gas

3. Ionization way EI,CI VS ESI, APCI

4.Application heat stability

Page 4: Principle and Application of  GC-MS

Principle of GC-MS

• 物理分离方法;• 组份沸点差异 & 分配系数的差异;• 质谱检测器 ---- 电离源 ---- 质谱碎片 ---- 谱库检 索 ---- 匹配度 ---- 完成定性。

Page 5: Principle and Application of  GC-MS

Process of GC-MS

Page 6: Principle and Application of  GC-MS

Manufacturer of GC-MS

• 美国 Agilent

• 日本岛津 Shimadzu

Page 7: Principle and Application of  GC-MS

6890N/5973C

Page 8: Principle and Application of  GC-MS

Chromatographic column

• Capillary column and packed column

Page 9: Principle and Application of  GC-MS

Preferences of capillary column• 内径 (inner diameter) : 0.25mm • 高柱效,低负荷量,必须分流进样或无分流进样。• 用于复杂多组份样品分析。• 柱长 (column length ) : 30m• 25—30m 中长柱:分离 10—50 个组份。 50m 长柱:分离大于 50 个组份或包含有难分离物质。• 膜厚 (film sickness) : 0.25—0.33μm• 对于流出达 300℃ 的大多数样品(包括蜡、甘油三酯、甾族化合物等)能够很好的分析。• 固定液 (stationary liquid)

分析时间加倍,分辨率增加 40%

Page 10: Principle and Application of  GC-MS

stationary liquid --- “ 相似相溶”• a. 非极性物质—非极性固定液;低沸点组分• b. 极性物质—极性固定液;小极性组分• c. 极性与非极性混合物—极性固定液;小极性组分• d. 易形成氢键物质—极性或氢键型固定液; 不易形成氢键的组分• e. 复杂难分离样品—多种固定液混合;

Page 11: Principle and Application of  GC-MS
Page 12: Principle and Application of  GC-MS

Sample preparation

• Without water and salt;

• Organic solvent with low boiling point;• 丙酮、正己烷、氯仿、苯等• 毛细管柱样品浓度 mg/ml 级或更低;• 进样量 ---- 进样方式而定• sample derivatization (样品衍生化)

Page 13: Principle and Application of  GC-MS

sample derivatization

• 硅烷化• 酰化• ( 1 )乙酰化(体内药物筛选,大多数的临床药物) ( 2 )三氟乙酰化 / 五氟丙酰化 / 七氟丁酰化(苯丙胺类和 麻黄碱类)• 烷基化(农药和杀虫剂)• 目的:改善待测物质的气相色谱性质如热稳定性、分 子质量、质谱行为;

Page 14: Principle and Application of  GC-MS

Preferences of GC-MS ----sample injection

• 自动进样( auto-injection )• 手动进样( hand-injection )

Page 15: Principle and Application of  GC-MS

split or not ? split ratio?

• 分流 (split)---- 主要组分分析;• 脉冲分流 (pulse split)---- 允许更大进样量;• 不分流 (splitless)---- 痕量组分分析;• 脉冲不分流 (pulse splitless)---- 允许更大进样量。

Page 16: Principle and Application of  GC-MS

carrier gas

• hydrogen ,nitrogen, argon, helium, Carbon dioxide

• flow rate : i.d<0.25mm : 0.5-3ml/min;• 0.32mm: 5-10ml/min;• 0.53mm: 5-20ml/min

• i.d<0.32mm ,衡流模式, 1.0ml/min;

Page 17: Principle and Application of  GC-MS

temperature of inlet

• 考虑样品的稳定性?

• 样品是否能够瞬间气化?

• 一般在 200~250℃

Page 18: Principle and Application of  GC-MS

column temperature program

• 影响样品分离度的最主要因素;• 升温慢可改善分离效果,增加分析的时间;• 升温快会加快载气流速,相近组分难完全分离 ;

• 柱温极限 ;

Page 19: Principle and Application of  GC-MS

Selection principle

• 在使最难分离的组分尽可能好的分离的情况下,尽可能采取 较低的柱温,但以保留时间适宜,峰形不拖尾为度。• 高沸点 300-400℃ ,低于其沸点 100-200 ;℃

• 沸点 200-300℃ ,中等柱温 ;

• 沸点 100-200 ℃ ,平均沸点的 2/3 左右• 气体,气态烃等,沸点或沸点以上

Page 20: Principle and Application of  GC-MS

Ionization source for GC-MS

• 样品分子 ---- 带电的离子 ---- 离子束 ---- 质量分析器 • EI : NIST 标准谱库, 70eV , 230℃ ,易挥发 成分• CI :软电离技术, EI 分析不了的物质,非标准质谱图• FAB, ESI, APCI for HPLC-MS

Page 21: Principle and Application of  GC-MS

Mass detector

分辨率 , 灵敏度 , 扫描速度

Page 22: Principle and Application of  GC-MS

Data acquisition

• 全扫描( Scan ) VS 选择离子扫描( SIM )

• 灵敏度: SIM 比 Scan 的高三个数量级

• 阈值的设置:为限制采集的峰数

Page 23: Principle and Application of  GC-MS

Qualitative analysis

• Library, • 一般为 probability-based matching (PBM) 检索• 匹配度≥ 80,• else AMDIS

• Research

Page 24: Principle and Application of  GC-MS

library• NIST:美国国家科学技术研究所出版• NIST/EPA/NIH:美国国家科学技术研究所、美国环保局、 美国国立卫生研究院共同出版• Wiley库 :3个版本,同一化合物可能有重复的不同来源的 质谱图• 农药库、药物库、挥发油库

• 前三个通用,后三个专用,NIST/EPA/NIH库应用最广泛。

Page 25: Principle and Application of  GC-MS

Some advice

• 1 EI , 70eV for NIST

• 2 纯化合物的质谱图 Subtract Background(BSB) & Savitzky-Golay

• 3 匹配度 ( 相似度 )& 其他有关信息

Page 26: Principle and Application of  GC-MS

• 仪器调谐方式不对• 数据采集时最强峰超量程• 采集数据或处理谱图时设定的低质量范围过高• 色谱分离不好,或本底峰干扰严重• 检索参数的选择(如质量范围等)

Influencing factor for library searching

Page 27: Principle and Application of  GC-MS

Quantitative analysis

• 面积归一化法 (area normalization method)

• 外标法 (external standard method)

• 内标法 (internal standard method)

Page 28: Principle and Application of  GC-MS

Area normalization method

• 方法:各组分浓度以面积百分率表示,可确认大概的浓度, 但有误差;• 要求:• 1 )所有物质都出峰,各物质响应因子接近,主要物质含量足够大,各峰型都较尖锐且对称;• 2 )峰高,只要不超过检测的线性范围最大值的一半就 行;

Page 29: Principle and Application of  GC-MS

External standard method

• 目前应用最广泛的方法之一;• 误差来源:主要是进样误差;• 解决办法:分析前一定要做面积重复性(即进样重复性)实验

Page 30: Principle and Application of  GC-MS

Internal standard method• 在样品中添加等体积等浓度的内标物,通过组分与内标峰 的面积比,对组分进行定量 ;

• 内标物选择原则:• 内标物的峰与试样中的所有成分的峰完全分离 ;• 内标物的峰与目标成分的峰保留时间不应差太远 ;• 内标物具有与分析目标成分类似的化学性质

Page 31: Principle and Application of  GC-MS

• RTE Integrator

• ChemStation Integrator

Integrator of chromatographic peak

Page 32: Principle and Application of  GC-MS

RTE

• 相对简单的色谱图(其中的峰很窄且已完全解析)• 尤其适用于 target compound analyses( 目标化合物分析 )• 缺省参数• 整个色谱图范围内 ; 毛细管色谱柱 ;总离子流

(TIC)

Page 33: Principle and Application of  GC-MS

ChemStation Integrator

• 各种类型色谱图的积分方便,直观,准确• 带有难于处理的基线和负峰的色谱图• 但自动编辑定量时,用 RTE 较好

Page 34: Principle and Application of  GC-MS

Application in my research

• 6890/5973, Agilent • auto sampler (7683B, Agilent) • Agilent HP-5MS capillary column (30m×0.25mm i.d., 0.25μm film),

• 1μl extracts solution (1g/ml, extracts/methanol) & n-Tridecane• split ratio 10:1• helium (1.0ml/min).

• column temperature programwas :• 60 (1 min), 60-140 at 4 /min, 140 (10min), 140-155 at ℃ ℃ ℃ ℃ ℃

3 /min,155 (2min),155-250 at 20 /min,250 (1min).℃ ℃ ℃ ℃ ℃• EI,70eV; • Inlet--250 , ionization source --230 , MS detector --150℃ ℃ ℃

• scan,m/z 40-500.

Page 35: Principle and Application of  GC-MS

参考文献• 1. N.Y. Qin, F.Q. Yang, Y.T. Wang, S.P. Li. Quantitative determination of eight

components in rhizome (Jianghuang) and tuberous root (Yujin) of Curcuma longa using pressurized liquid extraction and gas chromatography–mass spectrometry[J]. Journal of Pharmaceutical and Biomedical Analysis, 2007,43:486–492.

• 2. Li, M (Li, Ming) , Zhou, X (Zhou, Xin) , Zhao, Y (Zhao, Yang) , Wang, DP (Wang, Dao-Ping) , Hu, XN (Hu, Xiao-Na). Quality Assessment of Curcuma longa L. by Gas Chromatogrotphy-Mass Spectrometry Fingerprint, Principle Components Analysis and Hierarchical Clustering Analysis.Bulletin of The Korean Chemical Society[J].2009,30(10):2287-2293.

• 3. http://www.instrument.com.cn/netshow/SH100320/• 4.http://www.home.agilent.com/agilent/home.jspx?cc=CN&lc=chi• 5.汪正范 ,杨树民 ,吴侔天等 . 色谱连用技术 [M]. 化学工业出版社 .2001.• 6.王光辉 , 熊少祥 . 有机质谱解析 [M]. 化学工业出版社 . 2005.

Page 36: Principle and Application of  GC-MS

•Thank you!