prisma ipm switchboard air circuit breaker (acb) …...prisma ipm switchboard air circuit breaker...

19
3 Prisma iPM Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Upload: others

Post on 10-Apr-2020

51 views

Category:

Documents


0 download

TRANSCRIPT

3

Prisma iPM SwitchboardAir Circuit Breaker (ACB)Moulded-case Circuit Breaker (MCCB)ContactorPower meter

EasyPact TVSContactor

Easypact CVSMCCB

Easypact MVSACB

Schneider Electric makes it an ‘easy choice’ for your protection and control needs by offering a family of products that are: affordable, reliable, simple, and available

“The easy choice for quality, value, and peace of mind”

A cost-effective investment

The quality you demand

The performance you need

Easypact range is an excellent choice when tight

construction and upgrade budgets create a

challenge in meeting performance and protection

specification.

With simplicity of selection, ease of installation,

specification, selection, purchasing and stocking

Easypact family delivers unbeatable value

through its life cycle

Designed and manufactured by Schneider Electric

using advanced manufacturing methods and

premium materials, Easypact range is designed to

match your quality expectations and the needs of

each project

Prisma iPM Switchboard

PM 1200Power Meter

ACB Easypact MVS type N

ACB Easypact MVS type H

MCCB Easypact CVS 3P

MCCB Easypact CVS 4P

Contactor Easypact TVS

Thermal Overload Relay Easypact TVS

Power Meter, Easymeter PM1200

Type Tested Switchboard Prisma iPM

CONTENTS

..................................................... Page 4

..................................................... Page 6

......................................................... Page 8

....................................................... Page 10

..................................................... Page 12

.......................... Page 13

.................................... Page 14

............................. Page 15

EasyPact MVSAir Circuit breaker IEC 60947-2

The easy choicefor reliable performance

• Rated insulation voltage Ui: 1000V• Impulse withstand voltage Uimp: 12kV• Rated operating voltage Ue: 690VAC• Suitable for isolation IEC 60947-2 Yes• Degree of pollution IEC 60664-1: 4

4

TypeRated current In (A)No. of poleBreaking capacity Icu (kA rms)

Rated service breaking capacity Ics (kA rms)Rated short-time withstandcurrent Icw (kA rms)

MVS800

at 40 0C

220…440V690V

%Icu

1s 220…440V 690V3s 440/690V

N8003/45042

100%

50422525

<7020000

10000

6000

Breaking time (ms) between tripping order and arcextinction Closing time (ms)Service lifeC/O cycles

With maintenance

Without maintenance

Without maintenanceElectrical at 440VReference ordering and price (VND with VAT) - Fixed type 3P

Trip unit ET2I(long time, instantaneous)

MVS08N3MF2L

Reference ordering and price (VND with VAT) - Drawout type 3P

Trip unit ET2I(long time, instantaneous)

MVS08N3MW2L

Reference ordering and price (VND with VAT) - Fixed type 4P

Trip unit ET2I(long time, instantaneous)

MVS08N4MF2L

Reference ordering and price (VND with VAT) - Drawout type 4P

Trip unit ET2I(long time, instantaneous)

MVS08N4MW2L

70,624,000

97,058,000

87,574,000

120,352,000

Dimensions (mm)(HxWxD)

Drawout

Fixed

DrawoutFixed

3P4P3P4P

Weight (kg) (approximate)

3P/4P3P/4P

70/8540/50

Mechanical

Easypact MVS trip unitET2I (standard protection)

Easypact MVS trip unitET5I (selective protection)

Easypact MVS trip unitET6I (selective +earth fault protection)

Irt

0 I

tr

tr tr

Irt

0 I

Isdtsd

li

Isd

• Overload protection

• Short-circuit protection

• Instantaneous

• Overload protection• Short-circuit protection• Short time• Instantaneous

• Overload protection• Short-circuit protection• Short time• Instantaneous• Earth fault

l2t on

l2t offl2t on

l2t off

Ir

t

0 I

Isdtsd

li

VN-Public
Text Box
92,232,800
VN-Public
Text Box
101,406,800

NEW

MVS1000 MVS1250 MVS1600 MVS2000 MVS2500 MVS3200 MVS4000

N25003/45042

100%

50422525

<7020000

10000

5000

N32003/45042

100%

50422525

<7020000

10000

5000

N40003/45542

100%

55423025

<7020000

10000

5000

N20003/45042

100%

50422525

<7020000

10000

6000

N16003/45042

100%

50422525

<7020000

10000

6000

N12503/45042

100%

50422525

<7020000

10000

6000

N10003/45042

100%

50422525

<7020000

10000

6000

MVS10N3MF2L MVS12N3MF2L MVS16N3MF2L MVS20N3MF2L MVS25N3MF2L MVS32N3MF2L MVS40N3MF2L

MVS10N3MW2L MVS12N3MW2L MVS20N3MW2L MVS25N3MW2L MVS32N3MW2L MVS40N3MW2LMVS16N3MW2L

MVS10N4MF2L MVS12N4MF2L MVS16N4MF2L MVS20N4MF2L MVS25N4MF2L MVS32N4MF2L MVS40N4MF2L

MVS10N4MW2L MVS12N4MW2L MVS16N4MW2L MVS20N4MW2L MVS25N4MW2L MVS32N4MW2L MVS40N4MW2L

73,861,000 75,585,000 82,429,000 92,551,000 127,222,000 151,474,000 230,309,000

103,786,000 104,734,000 116,869,000 132,218,000 162,360,000 213,436,000 294,432,000

91,587,000 93,726,000 102,212,000 114,764,000 145,435,000 187,828,000 265,592,000

128,694,000 129,870,000 144,917,000 163,951,000 201,326,000 251,428,000 365,096,000439 x 441 x 395439 x 556 x 395352 x 422 x 297352 x 537 x 297

90/12060/80

5

Electrical accessories(220/240 V AC) 50/60Hz

Option accessories

MX, XF, MN

MCH

Gear motor (MCH)

Closing release (XF)

Opening release (MX)

Under voltage release (MN)

MN delay unit Rr (adjustable)

Reference

47894+ 47074 (fixed)47894+ 47849 (drawout)

MVS15512 + 47074 (fixed)MVS15512 + 47849 (drawout)

33662+ 47074 (fixed)33662+ 47849 (drawout)

33671 + 47074 (fixed)33671 +47849 (drawout)

33682

21,607,000

8,270,000

8,270,000

8,270,000

5,329,000

Unit Price List(with VAT)

VN-Public
Text Box
101,924,000
VN-Public
Text Box
117,216,000
VN-Public
Text Box
184,510,000
VN-Public
Text Box
92,767,000
VN-Public
Text Box
94,567,000
VN-Public
Text Box
106,938,000
VN-Public
Text Box
118,207,000
VN-Public
Text Box
121,205,000
VN-Public
Text Box
135,911,000
VN-Public
Text Box
98,331,000
VN-Public
Text Box
110,432,000
VN-Public
Text Box
112,670,000
VN-Public
Text Box
137,354,000
VN-Public
Text Box
225,224,000
VN-Public
Text Box
332,120,000
VN-Public
Text Box
160,103,000
VN-Public
Text Box
135,265,000
VN-Public
Text Box
133,211,000
VN-Public
Text Box
111,586,000
VN-Public
Text Box
109,054,000
VN-Public
Text Box
103,528,000
VN-Public
Text Box
267,839,000

EasyPact MVSAir Circuit breaker IEC 60947-2

The easy choice for reliableperformance

• Rated insulation voltage Ui: 1000V• Impulse withstand voltage Uimp: 12kV• Rated operating voltage Ue: 690VAC• Suitable for isolation IEC 60947-2 Yes• Degree of pollution IEC 60664-1: 4

TypeRated current In (A)No. of poleBreaking capacity Icu (kA rms)

Rated service breaking capacity Ics (kA rms)Rated short-time withstandcurrent Icw (kA rms)

MVS800

at 40 0C

220…440V690V

%Icu

1s 220…440V690V2s 440/690V

H8003/46550

100%

65503625

<7020000

10000

6000

Breaking time (ms) between tripping order and arcextinctionClosing time (ms)Service lifeC/O cycles

With maintenance

Without maintenance

Without maintenanceElectrical at 440VReference ordering and Price (VND) with VAT Fixed - type 3P

Trip unit ET2I(long time, instantaneous)

MVS08H3MF2

Reference ordering and Price (VND) with VAT- Drawout type 3P

Trip unit ET2I(long time, instantaneous)

MVS08H3MW2L

Reference ordering and Price (VND) with VAT- Fixed type 4P

Trip unit ET2I(long time, instantaneous)

MVS08H4MF2L

Reference ordering and Price (VND) with VAT- Drawout type 4P

Trip unit ET2I(long time, instantaneous)

MVS08H4MW2L

83,149,000

104,810,000

94,139,000

115,235,000

Dimensions (mm)(HxWxD)

Drawout

Fixed

DrawoutFixed

3P4P3P4P

Weight (kg) (approximate)

3P/4P3P/4P

70/8540/50

Mechanical

6

Easypact MVS trip unitET2I (standard protection)

Easypact MVS trip unitET5I (selective protection)

Easypact MVS trip unitET6I (selective +earth fault protection)

Irt

0 I

tr

tr tr

Irt

0 I

Isdtsd

li

Isd

• Overload protection

• Short-circuit protection

• Instantaneous

• Overload protection• Short-circuit protection• Short time• Instantaneous

• Overload protection• Short-circuit protection• Short time• Instantaneous• Earth fault

l2t on

l2t offl2t on

l2t off

Ir

t

0 I

Isdtsd

li

NEW

MVS1000 MVS1250 MVS1600 MVS2000 MVS2500 MVS3200 MVS4000

H25003/46550

100%

65503625

<7020000

10000

5000

H32003/46550

100%

65503625

<7020000

10000

5000

H40003/46550

100%

65503625

<7020000

10000

5000

H20003/46550

100%

65503625

<7020000

10000

6000

H16003/46550

100%

65503625

<7020000

10000

6000

H12503/46550

100%

65503625

<7020000

10000

6000

H10003/46550

100%

65503625

<7020000

10000

6000

MVS10H3MF2L MVS12H3MF2L MVS16H3MF2 MVS20H3MF2L MVS25H3MF2L MVS32H3MF2L MVS40H3MF2L

MVS10H3MW2L MVS12H3MW2L MVS20H3MW2L MVS25H3MW2L MVS32H3MW2L MVS40H3MW2LMVS16H3MW2L

MVS10H4MF2L MVS12H4MF2L MVS16H4MF2L MVS20H4MF2L MVS25H4MF2L MVS32H4MF2L MVS40H4MF2L

MVS10H4MW2L MVS12H4MW2L MVS16H4MW2L MVS20H4MW2L MVS25H4MW2L MVS32H4MW2L MVS40H4MW2L

84,829,000 86,885,000 89,575,000 100,064,000 114,521,000 131,703,000 207,315,000

105,417,000 107,462,000 116,237,000 128,486,000 136,185,000 152,709,000 300,943,000

98,613,000 105,813,000 106,882,000 119,397,000 126,595,000 154,330,000 253,061,000

117,646,000 123,925,000 121,289,000 144,795,000 151,983,000 179,891,000 373,169,000 439 x 441 x 395439 x 556 x 395352 x 422 x 297352 x 537 x 297

90/12060/80

7

Electrical accessories(220/240 V AC) 50/60Hz

Option accessories

MX, XF, MN

MCH

Gear motor (MCH)

Closing release (XF)

Opening release (MX)

Under voltage release (MN)

MN delay unit Rr (adjustable)

47894+ 47074 (fixed)47894+ 47849 (drawout)

MVS15512 + 47074 (fixed)MVS15512 + 47849 (drawout)

33662+ 47074 (fixed)33662+ 47849 (drawout)

33671 + 47074 (fixed)33671 +47849 (drawout)

33682

21,607,000

8,270,000

8,270,000

8,270,000

5,329,000

Reference Unit Price List(with VAT)

Easypact CVSMoulded case circuit breaker IEC 60947-2

The easy choice for qualityand value

• Adjustable trip unit from 0.7 to 1 x In• Icu=Ics=100%• Rated insulation voltage Ui: 690V• Impulse withstand voltage Uimp: 8kV• Rated operating voltage Ue: 440VAC• Suitable for isolation IEC 60947-2 Yes• Degree of pollution IEC 60664-1: 3• Utilisation category: A

TM-D thermal-magnetic trip units

600510 400

420

A

4200

4800 2400

3000

3600

A TM 600D600A/400C

Ir Im

Ir Im

TypeRated current No. of poleBreaking capacity Icu(kA rms)Trip unitDurability C/O cycles

CVS100

In at 400C

220/240V380/415V

MechanicalElectricalat 415V

In/2In

B

4025

F

7036

Reference ordering and price list (VND with VAT) - Fixed type 3PRated current In 16A

25A

32A

40A

50A

63A

80A

100A

125A

160A

200A

250A

320A

400A

500A

600A

3P

3P

LV510300

LV510301

LV510302

LV510303

LV510304

LV510305

LV510306

LV510307

2,460,000

2,460,000

2,460,000

2,460,000

2,460,000

2,460,00

2,487,000

2,487,000

Dimensions (mm)Fixed, front connections (WxHxD)

Weight (kg) Fixed, front

105 x 161 x 86

1.8

16-1003/4

TMD300003000012000

8

NEW

9

Thermal-magnetic trip unitsRatings (A)Magnetic protection

In at 40OC 16 25 32 40 50 63 80 100 125 160 200 250 320 400 500 600

TM16D to 250D TM320D to 600D(1)

Pick-up (A)accuracy+20%

ImCVS100CVS160/250CVS400CVS630

fixed190 300 400 500 500 500 640 800

800 1250 1250 2000 2500

adjustable

1600 to 3200 (320A), 2000 to 4000 (400A)2500 to 5000

CVS160 CVS250 CVS400 CVS630

B

4025

F

7036

B

4025

F

7036

F

4036

N

7050

F

4036

N

7050

LV510330

LV510331

LV510332

LV510333

LV510334

LV510335

LV510336

LV510337

2,554,000

2,554,000

2,554,000

2,554,000

2,554,000

2,554,000

2,649,000

2,649,000LV516302

LV516303

3,145,000

3,997,000

LV525302

LV525303

4,670,000

5,232,000

LV525332

LV525333

5,274,000

5,891,000

LV540305

LV540306

8,987,000

9,460,000

LV540315

LV540316

9,933,000

10,643,000LV563305

LV563306

12,298,000

14,190,000

LV563315

LV563316

14,190,000

15,254,000

LV516332

LV516333

3,406,000

4,304,000

1.8 2.0 4.7 5.2

105 x 161 x 86 105 x 161 x 86 140 x 255 x 110 140 x 255 x 110

100-1603/4

TMD250002500012000

200-2503/4

TMD200002000010000

320-4003/4

TMD15000120006000

500-6003/4

TMD1500080004000

Easypact CVSMoulded case circuit breaker IEC 60947-2

The easy choice for qualityand value

• Adjustable trip unit from 0.7 to 1 x In• Icu=Ics=100%• Rated insulation voltage Ui: 690V• Impulse withstand voltage Uimp: 8kV• Rated operating voltage Ue: 440VAC• Suitable for isolation IEC 60947-2 Yes• Degree of pollution IEC 60664-1: 3• Utilisation category: A

TypeRated current No. of poleBreaking capacity Icu(kA rms)Trip unitDurability C/O cycles

CVS100

In at 400C

220/240V380/415VMechanicalElectricalat 415V In/2

In

B

4025

F

7036

Reference ordering and price list (VND with VAT) - Fixed type 4PRated current In 16A

25A

32A

40A

50A

63A

80A

100A

125A

160A

200A

250A

320A

400A

500A

600A

4P

4P

LV510310

LV510311

LV510312

LV510313

LV510314

LV510315

LV510316

LV510317

3,287,000

3,287,000

3,287,000

3,287,000

3,287,000

3,287,000

3,477,000

3,477,000

Dimensions (mm)Fixed, front connections (WxHxD)

Weight (kg) Fixed, front

140 x 161 x 86

2.2

16-1003/4

TMD300003000012000

10

TM-D thermal-magnetic trip units

600510 400

420

A

4200

4800 2400

3000

3600

A TM 600D600A/400C

Ir Im

Ir Im

NEW

11

CVS160 CVS250 CVS400 CVS630

B

4025

F

7036

B

4025

F

7036

F

4036

N

7050

F

4036

N

7050

LV510340

LV510341

LV510342

LV510343

LV510344

LV510345

LV510346

LV510347

3,548,000

3,548,000

3,548,000

3,548,000

3,548,000

3,548,000

3,784,000

3,784,000LV516312

LV516313

4,730,000

5,383,000

LV525312

LV525313

6,460,000

7,323,000

LV525342

LV525343

7,342,000

8,321,000

LV540308

LV540309

10,406,000

11,589,000

LV540318

LV540319

12,535000

13,244,000LV563308

LV563309

15,373,000

16,319,000

LV563318

LV563319

16,555,000

17,974,000

LV516342

LV516343

4,974,000

5,851,000

2.3 2.6 6.3 7.1

140 x 161 x 86 140 x 161 x 86 185 x 255 x 110 185 x 255 x 110

100-1603/4

TMD250002500012000

200-2503/4

TMD200002000010000

320-4003/4

TMD15000120006000

500-6003/4

TMD1500080004000

Thermal-magnetic trip unitsRatings (A)Magnetic protection

In at 40OC 16 25 32 40 50 63 80 100 125 160 200 250 320 400 500 600

TM16D to 250D TM320D to 600D(1)

Pick-up (A)accuracy+20%

ImCVS100CVS160/250CVS400CVS630

fixed190 300 400 500 500 500 640 800

800 1250 1250 2000 2500

adjustable

1600 to 3200 (320A), 2000 to 4000 (400A)2500 to 5000

Easypact TVSConforming to standards IEC 60947-4-1, IEC 60947-5-1

Contactor

Rated operational current Auxiliary builtin contact

References Price

Coil voltage code (50Hz)

50 Hz

Coil voltage 24 48 110 220 240 380 415 440

B5 E5 F5 M5 U5 Q5 N5 R5

You need a 32 A contactor, 1 NC auxiliary contact, 24 V - 50 Hzcoil => LC1E3201B5

Example:

Accessories for LC1E contactor

Time delay auxiliary contact blocks for connection by screwclamp terminals 8 A - 690 V

Clip-onmounting

Front

Reference Price

ON DELAY 1NO +1NC - 30

LAETSD 894,000

Description

12

9

12

18

25

32

38

40

50

65

80

95

120

160

200

250

300

272,000272,000

308,000 308,000 456,000 456,000 556,000 556,000 816,000 816,000 958,000 958,000

988,000

1,017,000

1,148,000

1,419,000

1,786,000

2,188,000

4,849,000

5,215,000

7,509,000

8,846,000

1NO1NC1NO1NC1NO1NC1NO1NC1NO1NC1NO1NC

1NC+1NO

1NC+1NO

1NC+1NO

1NC+1NO

1NC+1NO

1NC+1NO

1NC+1NO

LC1E0910••LC1E0901••LC1E1210••LC1E1201••LC1E1810••LC1E1801••LC1E2510••LC1E2501••LC1E3210••LC1E3201••LC1E3810••LC1E3801••LC1E40••

LC1E50••

LC1E65••

LC1E80••

LC1E95••

LC1E120••

LC1E160••

LC1E200●●

LC1E250●●

LC1E300●●

Instantaneous auxiliary contact screw lamps terminals

Clip-onmounting

Front

Front

Front

Front

1 NC

1NO + 1NC

2NO

2NO + 2NC

Number ofcontacts

LAETSD LAEN22

Easypact TVS Thermal Overload relay

Possible ImaxCalibration

Compatible with Contactor(size 1 & 2) Com. Reference

References PriceList 2013

13

0.10 - 0.16

0.16 - 0.25

0.25 - 0.40

0.40 - 0.63

0.63 - 1

1 - 1.6

1.6 - 2.5

2.5 - 4

4 - 6

5.5 - 8

7 - 10

9 - 13

12 - 18

16 - 24

23 - 32

30 - 38

17 - 25

23 - 32

30 - 40

37 - 50

48 - 65

55 - 70

63 - 80

80 - 104

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E09 - E38

E12 - E38

E18 - E38

E25 - E38

E25 - E38

E38

E40 - E95

E40 - E95

E40 - E95

E50 - E95

E65 - E95

E80 - E95

E80 - E95

E95

LRE01

LRE02

LRE03

LRE04

LRE05

LRE06

LRE07

LRE08

LRE10

LRE12

LRE14

LRE16

LRE21

LRE22

LRE32

LRE35

LRE322

LRE353

LRE355

LRE357

LRE359

LRE361

LRE363

LRE365

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

292,000

564,000

564,000

564,000

564,000

564,000

564,000

1,690,000

1,690,000

Mechanical Interlock

Using 2 identical contactors

LC1E09 / E65

LC1E80 / E95

LC1E120 / E160

Reference

Price list 2013

LAEM1

LAEM4

LAEM5

68,000

154,000

617,000

LAEM1

blocks for connection by

Reference Price list 2013

LAEN02

LAEN11

LAEN20

LAEN22

81,000

81,000

81,000

162,000

14

PM1200Power Meter

The PowerLogic PM1000 series power meters are easy-to-use, cose-effective meters that offer the basic measurement capabilities required to monitor an electrical installation.

Charaterized by their rugged construction, compact size and low installation costs, these state-of-the-art multi-function meters are ideal for control panels, motor control centers and genset panels.

■ Power monitoring operations

■ Load studies and circuit optimization

■ Equipment monitoring

■ Meter’s outputs can be used by control devices

■ Preventative maintenance

The meter conforms to accuracly class 1.0 as per IEC 62052 - 11and IEC 62053-21

Easy-to-read display

Applications

Main characteristics

The color-coded analog load bar indicates the percentageof load through 12 LED segments.

The Turbo Key button lets you access the mose commonly viewedparameters or enter setup mode with a single push of the button.

Accurate metering

Analog load bar

The bright alphanumeric, 15mm-high LED display provides three lines for measurement valubes with four digits per line. The display auto-scales for Kito, Mega and Giga valubes. Auto scrolling mode allows for easy reading.

Turbo Key access to information

Quick and easy installationSetup is done through the front panel keys. Quick entry to setup during power up by TURBO key. Direct connection for metering voltage inputs up to 480 Vac L-L

Color-keyed terminal board labelingThe color-keyed label on the terminal board helps ensure accurate wining Secure settings

Commecial reference

METSEPM1200

Description Unit Price List(with VAT) Currency

PM1200 power meter withRS485 communication 11,036,000 VND

Innovate with

the Prisma iPM solution

A provensolution

100 % quality

fully IEC-compliantPrisma iPM:

Using our Prisma iPM solution, you can easily design, implement and operate LV electrical distribution and control switchboards that are dependable, because they are optimized, tested and compliant with the IEC 61439-1 standard.

15

Electrical characteristic

Mechanical characteristics

Applicable standards

System L System M Nominal rated current (A)

Rated insulation voltage Ui (VAC)

Rated operation voltage (VAC)

Rated impulse withstand voltage (KV)

Frequency (Hz)

Main busbar rated current max. Ie (A)

Rated short-time withstand current Icw (KA/1s)Rated peak withstand current Ipk (KA)

630

1000

690

8

50/60

630

25

53

up to 4000A

1000

690

12

50/60

3200/4000

85

187

Overall height (mm)

Number of vertical modules(functional height)1 module = 50mm

Dept (mm)

Width of enclosure for devices (mm)

Width of busbar duct (mm)

Width of cable duct (mm)

Partitioning

IP

IK

Color

Type test

IP class

Insulation material inside the enclosures

IEC61439-1

IEC60529

IEC60695

IEC61439-1

IEC60529

IEC60695

300 500 700 900 1100 1300 1650 1850

4 8 12 16 20 24 28 32

235

600

300

300

1

30/31/40/54

07/08/10

RAL 7047 (enclosure) and RAL 9022 (functional unit)

305

2000

36

400/600 (front access),800/1000 (rear access)600 and 800

200 (in 800 wide enclosure)

300

Form 1, 2, 3b and 4b

30/31/54

07/08/10

RAL 7047 (enclosure) andRAL 9022 (functional unit)

16

17

18

NOTES:

July 2013