process analyzers analyzers for boiler water applications ... short form catalog 2010… · process...

20
Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water applications Analyzers for oil refineries Water quality analyzers / Systems Ambient air analyzers Portable & handheld analyzers Laboratory analyzers Emission gas analyzers

Upload: nguyenphuc

Post on 06-Feb-2018

261 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

Process

analyzers

Analyzers for

water & waste

water treatment

Analyzers for

boiler water

applications

Analyzers for

oil refineries

Water quality

analyzers /

Systems

Ambient air

analyzers

Portable &

handheld

analyzers

Laboratory

analyzers

Emission gas

analyzers

Page 2: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

Creating the 21st Century Global EnvironmentDKK-TOA Corporation, a leading manufacturer of analytical instruments, would like to offer to your attention our highly reliable, excellent added-value analyzer to meet your requirements in a wide range of fields from ambient analyzers to science/pharmaceutical/food industry analyzers, and process controllers.

Ambient air analyzersAmbient air analyzers contributing to global environmental protection

Nitrogen Oxides Analyzer

Process analyzersAnalyzers and controllers to enhance productivity and efficiency in comprehensive production control and water treatment facilities

Analyzers for water treatmentAnalyzers for water quality management, ranging from the source of the water supply

to the end points of water distribution

Water quality analyzer for city water

Water quality analyzers / SystemsEnvironmental water quality analyzers adaptable to

advancing water treatment technologies

Total nitrogen/phosphorus/COD analyzer Automatic COD analyzer

Water quality analyzers of water purification system

Transmitters for industrial pH analyzers pH meter with auto-calibration

Page 3: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

Analytical instrumentsHighly reliable analyzers suitable for various environments, from field use to laboratory use

Environmental / Process analyzersProcess analyzers …………………… 1~6P

Analyzers for water & waste water treatment …………… 7~8P

Analyzers for boiler water applications ……………… 8P

Analyzers for oil refineries …………… 9P

Water quality analyzers / Systems ……………………………………… 10~11P

Ambient air analyzers ……………………12P

Emission gas analyzers …………………12P

Analytical instrumentsLaboratory analyzers ………………13~14P

Portable & handheld analyzers …15~16P

contents

pH meterR Series

Hand held pH meterP30 Series

Page 4: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

1

Process analyzers   pH meter  OPR meter

Environmental/Process analyzers

●Hart communication interface (version 7) using a 2 wire, 24 VDC circuit●Measurement of both pH or ORP available●Die cast aluminum case, digital display and a wide range of other useful features●One touch auto calibration●Self diagnosis●Measurement range: -1.00~15.00(pH), -2,000~2,000mV(ORP)

pH/ORP Transmitter with Hart communication interface

HBM-165H(2-wire)

●Compact DIN96 size●Auto determination system for deterioration of electrode ●Optional RS-232●Power source: AC90~264V, 50/60H●Adjustable output span●Upper & lower limit control function●Meas. range : pH meter(HBM-100A) : -1~15pHORP meter(HBM-102A) : -2,000~+2,000mV

Panel mount pH/ORPcontrollers

HBM-100A/HBM-102A

●Easy-to-use ORP analyzer for field installation in a compact and rigid aluminum case ●Automated check with a standard solution; auto determination of electrode deterioration●Alterable output range●Self-diagnostic function for failure (burn-out output)●Meas. range: -2,000~+2,000mV

Transmitter for industrial ORP analyzer

HDM-137A(2-wire)HDM-138A(4-wire)

●Easy-to-use pH analyzer for field installation in a compact and rigid aluminum case ●Easier procedure for calibration with a standard solution; auto determination of electrode deterioration●Alterable output range●Self-diagnostic function for failure (burn-out output)●Meas. range: pH: -1~14

Transmitter for industrial pH analyzer

HDM-135A(2-wire)HDM-136A(4-wire)

●The metal electrode tip and a reference electrode junction tip are easily exchangeable●Platinum electrodes(PSS)and gold electrodes(ASS)are available●KCl non-supply type for waste water treatment, KCl supply type for processes●Immersion/drop-in/flow-through type electrode holders are available

●Meas. range: -2,000~+2,000 mV

Exchangeable tipORP electrode

PSS/ASS‐304B(KCl non-supply type)PSS/ASS‐314B(KCl supply type)

●The glass electrode tip and reference electrode junction tip are easily exchangeable●Alkali-resistant glass tips and hydrofluoric-acid-resistant glass tips are available

●KCl non-supply type for waste water treatment, KCl supply type for processes

●Immersion/drop-in/flow-through type electrode holders are available

●Meas. range: pH: 0~14

Exchangeable tippH electrode

GSS‐304B(KCl non-supply type)GSS‐314B(KCl supply type)

●Transparent PVC holder(heat resistance: 60℃)or semi-transparent PP holder (heat resistance: 80℃)●Length: 0.5~3.0 m●KCl supply type holder retains KCl inside●Mounting bracket, mounting flange, etc. are available

Exchangeable tip immersion type electrode holder

HC-G70

基本プロセス計測器

Intrinsically safe explosion-proof type transmitter for industrial pH/ORP analyzer

●Compact die-cast aluminum case●Explosion protection mark: ExiallCT4 (combined with a Zener Barrier); protection structure: IP65●Easier procedure for calibration with a standard solution; electrode deterioration detection function; free range setting

●Meas. range:pH meter(SHBM-161) : pH: -1~15ORP meter(SHBM-163): -2,000~+2,000mV

SHBM-161/163(2-wire)

●Rigid aluminum case for any installation position

●Intrinsically safe explosion-proof construction, conforming to IEC (Ex) (combined with a Zener Barrier)

●Easier procedure for calibration with a standard solution; electrode deterioration detection function; free range setting

●Meas. range:pH meter(SPCP-20T) : pH: 0~14ORP meter(SRCP-20T): -2,000~+2,000mV

SPCP-20T/SRCP-20T(2-wire)

●Throw-in type for deep tanks or drop-in type with a protection pipe●Transparent PVC detector(heat resistance: 60℃)●SUS protection pipe(maximum length: 5 m)and mounting bracket are available

Exchangeable tip drop-in type electrode sensor

HC-G95

●HC-G80: transparent PVC holder (heat resistance: 60℃) (maximum pressure resistance: 0.3 MPa)●HC-G82: PP/SUS316 holder(heat resistance: 80℃) or PVDF/SUS316 holder(heat resistance: 100℃) (maximum pressure resistance: 0.5 MPa)

Exchangeable tip flow-through type electrode holder

HC-G80/G82

Transmitter for industrial pH/ORP analyzer

HBM-160/HBM-162(4-wire)

●Multi-function pH/ORP analyzer for field installation in a compact die-cast aluminum case●Single-operation automated calibration and various self-diagnostic functions●Two circuit transmission output for pH/ORP and sample temperature with freely settable output range

●Power source: AC90~264V, 50/60H●Meas. range:pH meter(HBM-160) : pH: -1~15ORP meter(HBM-162): -2,000~+2,000mV

Process

analyzers

Environmental/Process analyzers

Page 5: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

2

Process analyzers   pH meter  OPR meter

●Best suited for measurement of pure water, like boiler water, with a high resistivity level●Accurate results attainable with a small sample because sample is discarded after each measurement●Electrode to be combined: MG-511-2F(glass electrode), 4164-2F (reference electrode), 6149-2F (temperature compensation electrode)

PH sensor for pure water measurement

HC-64

●Detector used for measuring pH/ORP in closed loop lines where there is a process pressure, such as in plumbing lines, sealed tanks, etc.●Electrode assembled into an electrode holderElectrode to be combined: 5610 (KCl supply type), 5910 (KCl non-supply type)

Flow-through typepH/ORP sensors

HC-8series

●Best suited for pH/ORP measurement in tanks or open waterways

●Electrode assembled into an electrode holderElectrode to be combined: 5600(KCl supply type), 5910(KCl non-supply type)●Flanges for mounting sensors to the tank are available(50A, 100A, 150A)

Immersion typepH/ORP sensors

HC-7 series

●Immersion type (UHC-7C)/Flow-through type (UHC-8C), sensor with electrode holder and ultrasonic cleaning system●Ease of maintenance like calibration with standard solution due to single action detachable electrode holder

Flow-through type sensorwith ultrasonic cleaner

UHC-7C/8C

●Immersion type pH/ORP electrode holder with cleaning brush (BHC-7C), electrode holder with cleaning brush & water-jet cleaner functions (BJHC-7C)●Brush swings & washes tip of electrode to prevent fouling ●Cleaning takes place in fresh water thus highly effective (BJHC-7C)

●Single action detachable electrode holder enables easy maintenance

Immersion type pH/ORPsensor with brush cleaner

BHC-7C/BJHC-7C

●Immersion type electrode holder combined with chemical cleaning system(RHC-7C) & brush cleaningfunction as additional feature (BRHC-7C)●Air & cleaning agents sprayed ontoelectrode tip to dissolve away fouling

Immersion type sensorwith chemical cleaner

RHC-7C/BRHC-7C

●Immersion type (JHC-7C)/Flow-through type (JHC-8C), sensor combined with electrode holder and water-jet cleaner ●Water sprayed onto tip of electrode &water pressure washes away fouling

●Single action detachable electrode holder enables easy maintenance●Simple installation with sensor, timer & electromagnetic valve built into one unit

Immersion type sensorwith water jet cleaner

JHC-7C/8C

●Immersion type pH/ORP electrode holder combined with pulse air jet cleaner●Cleaning by high-speed water stream created by the rapid expansion of pulse-jetted compressed air in the sample water●High cleaning effect due to airbubbles present in the waterstream randomly hitting theelectrode●No consumables required, suchas reagents, brushes

Immersion type sensorwith pulse air jet cleaner

PHC-7E

●Suitable for bio-process tanks (fermentation tanks), KCl non-supply and leadless type, steam sterilizable, strong glass membrane, lead-free safe design●Liquid junctions of both pressurized gel type products (ELP-005/006/007) and double junction type products (ELP-045/046/047/048) are stable●Various electrode lengths are available according to various tank sizes

●Meas. range: pH: 0~14

PH electrode forbio-process tanks

ELP-005/006/007ELP-045/046/047/048

●Automated electrode cleaning and 2-point calibration by standard solution

●Low maintenance, long term and high reliability pH measurements

●Safe, high cleaning effect due to lift-up type, midair jet cleaning/calibration

●Helpful, practical self-diagnosis message display

●Meas. range : -1~15pH

●Installation is easy, because the transmitter system for the pH analyzer for field installation and the detector with the chemical cleaner can be mounted on a pole stand●Labor saving for maintenance, and highly reliable pH measurement control over a long period are possible in waste water treatment facilities, etc.

●No need to specify individual type names, including those for the mounting brackets

●Meas. range : pH: -1~15, -5~100℃

PH meter with chemical cleaner

PAC‐R7

pH meter withauto-calibration

MAC-355

(brush & water -jet cleaner)

Process

analyzers

Page 6: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

3

Process analyzers   Conductivity analyzer / Resistivity analyzer

Environmental/Process analyzers

●Compact DIN 96 size ●Best suited for water quality control in ultra pure water producing equipment & production lines of semiconductors with built-in micro-computer for water quality monitoring●Two sensors connectable (display switchable)●Output : 2 circuit insulated type with 4~20mA

●RS-232 equipped as standard specification

●Meas. range: 0.00~20.00MΩ・cm

Panel type resistivitymonitor

AQM-210A

●Compact DIN96 size●Best suited for water qualitycontrol in ultra pure waterproducing equipment & productionlines of semiconductors with built-in microcomputer for water qualitymonitoring●Two sensors connectable (display switchable)

●Meas. range: 0.00~20.00MΩ・cm

Resistivity monitor forultra-pure water

AQM-100A

●Hart communication interface (version 7) using a 2 wire, 24 VDC circuit●Die cast aluminum case, digital display and a wide range of other useful features●One touch auto calibration●Self diagnosis●Measurement Range: Minimum : 0~0.2μS/cmMaximum: 0~20mS/cm

Conductivity transmitter with hart communication interface

WBM-165H(2-wire)

●Compact DIN 96 size unit●Conductivity meter with built-in microcomputer suitable for all types of solutions, such as ultra-pure water production systems, boiler plants, foodstuff plants, etc.●Transmission output: 2-circuit insulated type with 4-20mA●Two sensors can be connected●RS-232 equipped as standard specification

●Meas. range: Minimum : 0~0.2μS/cmMaximum: 0~20mS/cm

Panel typeconductivity converter

WBM-210A

Transmitter for industrial conductivity analyzer

●Multi-function conductivity analyzer for field installation in a compact die-cast aluminum case●Wide measurement range, from ultra-pure water to wastewater●Two circuit transmission output for conductivity and sample temperature with freely settable output range optional RS-232 output●Power source: AC90~264V, 50/60Hz●Meas. range: Minimum : 0~0.2μS/cmMaximum: 0~20mS/cm

WBM-160(4-wire)

●Easy-to-use conductivity analyzer for field installation in a compact and rigid aluminum case ●Wide measurement range, from ultra-pure water to wastewater ●Alterable output range●Meas. range: Minimum : 0~0.2μS/cmMaximum: 0~20mS/cm

WDM-135A(2-wire)WDM-136A(4-wire)

●Compact DIN 96 size unit●Sanitary conductivity analyzer exclusive to the food industry●To be installed in pipes and tanks, etc.; best suited for the use in CIP (stationary cleaning), liquid level and debubbling agent control

●Meas. range:0~0.2/2 mS/cm(at 25℃)0~20/200 mS/cm(at 25℃), etc.

Sanitary typeconductivity analyzer/detector

WBM-120/AK Cell

●Open angle mounting with rigid aluminum case●Intrinsically safe explosion-proof construction conforming to IEC (Ex) (combined with a Zener Barrier)●Operation and wiring possible from front surface

●Meas. range:Standard cell constant value: 0.01~10.0/cmMeas. range: 0~10.00 mS/cm(at 25℃)

Intrinsically safe explosion-proof type conductivity converter

SECP-20T(2-wire)

●Compact 2-electrode type (titanium) detector for ultra-pure water

●Pipeline insertion type, leadless●Two types of cell constants are available: 0.01, 0.1 cm-1

●Meas. range:0~20/200MΩ·cm0~0.2/2μS/cm

Industrial resistivity/conductivity sensor

●Hermetically sealed 2-electrode type detector with excellent heat proofing and pressure tightness●Pipeline insertion/immersion/flow-through/throw-in, etc. types, leadless●Four types of cell constants are available: 0.01, 0.1, 1.0, 10 cm-1

●Meas. range:Minimum : 0~0.2μS/cmMaximum: 0~20mS/cm

Industrial conductivity sensor

AR cell series

Conductivity sensor with amplifier

●Single-function (no indication) conductivity analyzer for field installation●Installation is easy because an amplifier is combined with the detector●Output: DC 4-20mA, power source: AC 100V

●Meas. range:AA-1: 0~2μS/cm to 0~10,000μS/cmAA-2: 0~0.2/0.5/1.0μS/cm

AA-1(for standard use)AA-2(for ultra-pure water)

A cell series

●Compact DIN 96 size unit●Temperature compensation by micro-computer operation●Cell constant value adjusting function

●Display of water temperature is available●Power source: AC90~264V, 50/60Hz●Meas. range: Minimum : 0~0.2μS/cmMaximum: 0~20mS/cm

Panel type conductivity analyzer

WBM-100

Process

analyzers

Environmental/Process analyzers

Page 7: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

4

●Toroidal type Teflon detector with excellent corrosion/heat/pressure resistance●Accurate results for high conductivity corrosive solutions(such as strong acid/alkal)●Flow-through/immersion/pipeline insertion, etc. types standardized

●Meas. range:Minimum : 0~2mS/cmMaximum: 0~2,000mS/cm

Electromagnetic conductivity sensor

ME-6/7/11T series (high sensitivity type)

●Panel type compact DIN 96 size unit; electromagnetic conductivity analyzer●Accurate results for high conductivity corrosive solutions(such as acid and alkali), which are not attainable with 2-electrode type detectors●Two-point regulated output, 4-20 mA output, optional RS-232 output

●Meas. range:Minimum : 0~2mS/cmMaximum: 0~2,000mS/cm

Panel type electromagnetic conductivity analyzer

MBM-100A

●Electromagnetic concentration/conductivity analyzer with intrinsically safe explosion-proof construction(combined with a Zener Barrie)●Storage function for data on conductivity/concentration characteristics and temperature characteristics of chemicals●Measurement range adjustable to user's request

●Examples of measurement ranges: NaCl: 0~10%, HCl: 30~40%, H2SO4: 93-99.5%, NaOH: 0~15%Minimum : 0~2mS/cmMaximum: 0~2,000mS/cm

Intrinsically safe explosion-proof model magnetic concentration meter/conductivity meter

SMDM-301(2-wire transmitter)SME-11T(sensor)

●Panel type compact DIN 96 size unit; electromagnetic concentration analyzer●Conductivity data for NaCl, HCl, H2SO4, etc. are measured and converted to concentration(%) data●Measurement range adjustable to user's request●Two-point regulated output, 4-20 mA output, optional RS-232 output

●Examples of measurement ranges: NaCl: 0~10%, HCl: 30~40%, H2SO4: 93~99.5%, NaOH: 0~15%

Panel type electromagnetic induction concentration analyzer

MBM-102A

●Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum case ●Accurate results for high conductivity corrosive solutions (such as acid and alkali), which can't measure 2-electrode type detectors●Alterable output range●Meas. range: Minimum : 0~2mS/cmMaximum: 0~2,000mS/cm

Transmitter for electromagnetic conductivity analyzer

●Electromagnetic conductivity analyzer for field installation in a compact die-cast aluminum case●Accurate results for high conductivity corrosive solutions(such as acid and alkali), which can't measure 2-electrode type detectors

●2-way signal output, including Two-point regulated output and, sample temperature: optional RS-232 output

●Power source: AC90~264V, 50/60H●Meas. range:Minimum : 0~2mS/cmMaximum: 0~2,000mS/cm

●Electromagnetic concentration analyzer for field installation in a compact die-cast aluminum case●Conductivity data for NaCl, HCl, H2SO4, etc. are measured and converted to concentration(%) data●Measurement range adjustable to user's request●2-way signal output, including Two-point regulated output and, sample temperature: optional RS-232 output

●Power source: AC90~264V, 50/60H●Examples of measurement ranges: NaCl: 0~10%, HCl: 30~40%, H2SO4: 93~99.5%, NaOH: 0~15%

Transmitter for electromagnetic concentration analyzer

MBM-162(4-wire)

Transmitter for electromagnetic conductivity analyzer

MBM-160(4-wire)MDM-135A(2-wire)

●Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum case ●Conductivity data for NaCl, HCl, H2SO4, etc. are measured and converted to concentration(%)data●Measurement range adjustable to user's request

●Examples of measurement ranges: NaCl:0~10%, HCl: 30~40%, H2SO4: 93~99.5%, NaOH: 0~15%

Transmitter for electromagnetic concentration analyzer

MDM-137A(2-wire)

Process analyzers   Electoromagnetic Conductivity Angalyzer

●Compact toroidal type heat resistant PVC/Teflon detector with excellent corrosion resistance●Accurate results for high conductivity corrosive solutions(such as strong acid/alkali) ●Flow-through/immersion/pipeline insertion/throw-in, etc. types standardized

●Meas. range:Minimum : 0~2mS/cmMaximum: 0~2,000mS/cm

ME-100 series (compact and lightweight leadless type)

Process

analyzers

Page 8: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

5

Process analyzers   Dissolved Oxygen Analyzers

Environmental/Process analyzers

●Panel type dissolved oxygen analyzer in a compact DIN 96 size●Two-point regulated output, 4-20 mA output, optional RS-232 output ●Single-operation automated calibration and various self-diagnostic functions●Power source: AC90~264V, 50/60Hz●Meas. range: Minimum : 0~1mg/LMaximum: 0~50mg/L

Panel type DO transmitter

OBM-102A

●Cleaning electrode contamination by jetting water or air onto the electrode●Immersion type(JOC-711C), drop-in type(JOC-950C) ●Electrode: polarograph type 7533L (for standard use) or 7536L(for human waste)

Sensor with water jet cleaner

JOC-711C/950C

●Multi-function low-concentration dissolved oxygen analyzer for field installation in a die-cast aluminum case●Three ranges (automatically switched), two-point regulated output●Alterable output range●Single-operation automated calibration and various self-diagnostic functions

●Meas. range: Minimum : 0~20μg/LMaximum: 0~2,000μg/L

●Easy-to-use low-concentration dissolved oxygen analyzer for field installation in a compact and rigid aluminum case●Easier procedure for calibration; auto determination of electrode deterioration●Alterable output range●Self-diagnostic function for failure (burn-out output)●Meas. range: Minimum : 0~20μg/LMaximum: 0~2,000μg/L

Transmitter for industrial low-concentration DO analyzer

ODM-100A(2-wire)ODM-110A(4-wire)

●Powerful cleaning electrode contamination with water flow and bubbles caused by pulse-jetted compressed air(plant air) in the sample water●Air pump unit as a compressed air source(optional)●Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)

Immersion type sensor with pulse air jet cleaner

POC-7E

Low-concentrationDO transmitter

OBM-300(4-wire)

●Suitable for low-concentration DO measurement(e.g. pure water in semiconductor factories, boiler water in power plants)

●Micro-flow(100 mL/min)with special flow cell●Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode); lead wire: ELW-32

Low-concentrationDO sensor for pure water

OC-64

●Panel type low-concentration dissolved oxygen analyzer in a compact DIN 96 size●Two-point regulated output, 4-20 mA output, RS-232 output●Single-operation automated calibration and various self-diagnostic functions●Power source: AC90~264V, 50/60Hz●Meas. range: Minimum : 0~20μg/LMaximum: 0~2,000μg/L

Panel type low-concentration DO transmitter

OBM-100H

●Lightweight PVC holder; length of immersion type holder: 0.3-3.5 m, length of stainless steel protection pipe for drop-in type holder: 2-6 m●Electrode: polarograph type 7533L (for standard use) or 7536L(for human waste)

Immersion/drop-in type DO electrode holder

OC-711/950

●Polarograph type dissolved oxygen analyzer with intrinsically safe explosion-proof construction (combined with a Zener Barrier)●Alterable output range●Sensors for immersion/flow-through and sensors for fermentation are available; electrode: ELD-017/019, etc.

●Meas. range: Minimum : 0~1mg/LMaximum: 0~20mg/L

Intrinsically safe explosion-proof type DO transmitter

SOD-35D(2-wire transmitter)SOC-71(sensor)

●Multi-function dissolved oxygen analyzer for field installation in a die-cast aluminum case●2-way signal output, including Two-point regulated output and, sample temperature; optional RS-232 output

●Single-operation automated calibration and various self-diagnostic functions●Power source: AC90~264V, 50/60Hz●Meas. range: Minimum : 0~1mg/LMaximum: 0~50mg/L

Transmitter for industrial DO analyzer

OBM-162(4-wire)

●Easy-to-use dissolved oxygen analyzer for field installation in a compact and rigid aluminum case●Easier procedure for calibration; auto determination of electrode deterioration●Alterable output range●Self-diagnostic function for failure (burn-out output)●Meas. range: Minimum : 0~1mg/LMaximum: 0~50mg/L

Transmitter for industrial dissolved oxygen analyzer

ODM-135A(2-wire)ODM-136A(4-wire)

Process

analyzers

Environmental/Process analyzers

Page 9: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

6

●Process analyzer for automating analytical techniques such as atomic absorption, etc.●Suitable for automating chemical analysis processes such as distillation, heat treatment, etc

●Applications:Total chromiumTotal cyanide by atomicabsorption/distillationPhenols by atomic absorption/distillationTotal mercury by oxidation-reduction atomic absorption

Automatic processanalyzer

XAT-200 series

●Best suited for accurate measurementof SiO2 ultra pure water used forboiler & VLSI manufacturing●Molybdenum blue absorptiometric principle employed as measurement method●Three types instruments available for response against wide measurement range

●Meas. range ; Extremely low concentration: 2 ranges between0~10 &0~500ppb (SLC-1605)Low concnetration: 2 ranges between 0~50 & 0~5,000ppb (SLC-1615)High concentration:2 ranges between 0~5, 0~50ppb(SLC-1625)

Silica analyzer

SLC-1605/1615/1625 series

Process analyzers   

●Compact & light-weight model with accordance of DIN standard●Built-in DC power source model for 4-point alarm & 2-wire transmitter

●Usable as receiver of 2 or 4 wire transmitter such as pH / ORP meter,conductivity analyzer or DO meter

●Meas. range : pH meter:0~14 70divisions (to be specified otherwise)

Bar graph meter relay

BMR-24

Process

analyzers

Page 10: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

7

Analyzers for water & waste water treatment

Environmental/Process analyzers

●(Total or free) residual chlorine in the chlorination process for water purification continuously measurable with polarographic method

●Reagent requirement is 1/5 that of existing models●RS-485 equipped as standard specification; compatible with Modbus communication system●Freely mountable on walls, racks, etc. due to compact and lightweight design

●Meas. range: 0~0.5/1.0 to 0~5/10mg/L(ppm)(Two ranges)

●Free residual chlorine in clean water in the chlorination process continuously measurable with reagentless polarographic method●RS-485 equipped as standard specification; compatible with Modbus communication system●Freely mountable on walls, racks, etc. due to compact and lightweight design

●Meas. range: 0~1/2, 0~1/3, 0~2/3mg/L(ppm)(Two ranges)

Reagentless free chlorine analyzer

CLF-1610

●Measures free residual chlorine ofchlorinated water from purification/food processing/semiconductor plants & pool water without reagent●Continuous measurement by Polarographic method

●Meas. range: CD-36D; 0~2mg/L (ppm), CD-38D; 0~100mg/L (ppm)

●Simultaneous measurement of color & turbidity by single beam, dual wavelength absorptiometry

●Meas. range: Color; 0~10/20/30DEGturbidity; 0~4/5/10mg/L

Color / turbidity meter

COL-11

Reagentless free chlorine analyzer

●Highsensitivity turbidity analyzer suitable for water in the water purification process●Surface light scattering method, 1 range/2 ranges/3 ranges are available●RS-485 equipped as standard specification; compatible with Modbus communication system●Freely mountable on walls, racks, etc. due to compact and lightweight design

●Meas. range: 0~0.2 to 0~2.0 (1~3 ranges)(Units: degrees, NTU)

●Integrating sphere system that is popular as lab turbidity method is adopted●Analyzer to continuously measure turbidity of tap water, river water, industrial water, etc.●Accurate turbidity measurement capability with minimal color influence

●Meas. range: 0~0.5/5 to 0~100/1,000Cell length: 50mm or 10mm (selectable)(Units: degrees, mg/L, ppm, FTU, NTU)

Turbidity meter with integrating sphere

TUI-100

High sensitivity turbidity analyzer

TUH-1600

●Ultra Compact DIN48 size●Power source : AC 100~230V●Low power consumption of 5VA●No reagent necessary●Self cleaning by polishing beads and micro-vibrating electrode

●Meas. Range: 0~3mg/L

●Measures chloride demand of water & estimates chlorine injection level thus best suited for feed forward control●Fast response attainable by adding exceeding amount of chlorine to sample, resultant chemical reaction used as indication of residual chlorine level for determination of chlorine demand

●Meas. range: From 0~5mg/L to 10mg/L (ppm),from 0~10mg/L to 20mg/L (ppm)

●Suitable for water in the water purification process (including river water, etc.)

●Surface light scattering method, 1 range/2 ranges/3 ranges are available●Sample water flow rate is 1/2 that of existing models●RS-485 equipped as standard specification; compatible with Modbus communication system●Freely mountable on walls, racks, etc. due to compact and lightweight design

●Meas. range: 0~2 to 0~2,000 (1~3 ranges)(Units: degrees, mg/L, ppm, FTU, NTU)

Turbidity analyzer

TUF-1600

Chloride demand analyzer

CLD-7M

Residual chlorine analyzer

CLBM-50CD-36D/38D

Residual chlorine analyzer

●Measures total residual chlorine of drainage water without reagent●Continuous measurement by Polarographic method

●Meas. range: 0~0.5/1.0, 0~1/2, 0~2/3mg/L (ppm)

Reagentless residualchlorine analyzer

CLF-120

CLF-1600

●World’s smallest A4 size multiparameter water quality analyzer●Turbidity, color, residual chlorine, pH, conductivity, temperature and pressure continuously measurable without reagents

●Small sample requirement and cost effective●Suitable for monitoring of distribution point and water in conduits

Automatic water quality analyzer for city water

MWA4-70/30

●B4 size compact analyzer excellent in reliability, durability and maintainability●Turbidity, color, residual chlorine, pH, conductivity, temperature and pressure continuously measurable without reagents

●Easy-to-see and easy-to-understand due to color touch screen and interactive operation

MWB4-70

Analyzers for

water & waste

water tre

atment

Environmental/Process analyzers

Page 11: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

8

Analyzers for water & waste water treatment

●Best suited for measurement of high SS concentration (i.e. 2~3 %) sinceaffects of color eliminated by use of3 photo cells ●Direct insertion of detector into subjected pipe ●Use of pipe insertion adopter enables extraction of detector without suspending plant operation

●Meas. range: 0~5% or 0~10%

●Continuous measurement of (total) alkalinity of water in the water purification process is available with the coulometric titration method

●Sample requirement is 1/4 that of existing models●RS-485 equipped as standard specification; compatible with Modbus communication system●Freely mountable on walls, racks, etc. due to compact and lightweight design

●Meas. range: 0~50/100mg/L (ppm)(Two ranges)

Alkalinity analyzer

ALF-1600

●2 sand filter columns cleaned alternately for continuous supply of sample solution

●Filtration rate : 1~6L/min (varies with sample turbidity)

Sand filter

FS-3

SSD-30-1( )

●Continuous optical measurement of SS/MLSS concentration in sample using near infrared light scattering method●Compact and lightweight stainless steel detector enabling safe and easy maintenance

●Meas. range: 0~1,000/3,000 to 0~5,000/10,000/20,000mg/L (ppm)(Two or three ranges)

Suspended solids concentration analyzer

SSF-10

●Immersion, drop-in, and pipeline insertion type sensors with lighter body and higher maintainability●High reliability and low running cost with the long lasting optical source●Constructed to have less natural light from the exterior●Self-cleaning function●Meas. range: SSD-310 : 0~1,000mg/L (ppm), SSD-320: 0~20,000mg/L (ppm)(SSD-320 may be used as an MLSS analyzer in activated sludge processes)

SSD-310( )SSD-320( )

●Cooler, pressure reducer, valves, flowmeter & thermostat chamber all built into one unit●Extraction of sample for analysis from boiler

●We manufacture whole system from analyzer to sampler

●Sample condition : Maximum temperature:600℃,maximum pressure :30MPa,maximum flow rate :3L/min

●Continuously measures Na+ ion concentration of ppb order within boiler water●Monitors degradation of ion-exchange system

●Meas. range: 0~0.1/1~100/10~1,000ppb (manually swtiched)

●Continuous measurement of hydrazineconcentration in boiler water●Stabilization determination function during calibration●Best suited for monitoring of residual hydrazine concentration which eliminates dissolved oxygen in boiler water

●Meas. range : 0~999.9μg/L

Hydrazine analyzer

HYM-300Sodium ion monitor

EMNA-10Boiler sampling system

BSC

Analyzers for boiler water applications

ZSSP-1

for lowconcentration

for mediumconcentration

for highconcentration

Analyzers for

water & waste

water treatment

Analyzers for

boiler water

applications

Page 12: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

For heavy fuel oil C

9

Analyzers for oil Refineries

Environmental/Process analyzers

●Automatic analyzer for oil refinery●Measures pour point which is the indication of light oil & intermediate fraction of fuel oil A continuously

●Best suited for management of plant & product control

●Meas. range : -30℃~+20℃

●Automatic analyzer for oil refinery●Measures plugging pour point which is the indication of light oil & intermediate fraction of fuel oil A continuously ●Best suited for management of plant & product control

●Meas. range : -30℃~+20℃

●Analyzer for oil refinery●Batch continuous analysis of flash point of petroleum products like light gas oil, kerosene & gasoline ●Best suited for management of plant & product control

●Meas. range : 0~100℃

●Analyzer for oil refinery●Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil & gasoline●Best suited for product control & monitor of distillation tower●Contribute to increasing production of middle distillate

●Meas. range : standard:light gas oil(0~400℃), kerosene(0~300℃), gasoline(0~200℃)

●Automatic analyzer for oil refinery●Measures cloud point of petroleum products like gas-oil continuously●Best suited for management of plant & product control

●Meas. range : -30℃~+20℃

●Measures color of oil products and coloration due to heavy oil mixing in heatconverters, etc.●Measures broad range of wavelengths by compact-type onboard spectroscope●Saybolt color, ASTM color, APHA color measurement available

●Automatic analyzer for oil refineries● Batch/continuous analyzer measuring sulfur concentration of petroleum products like light and heavy oil ● Best suited for product and quality control of petroleum products● RI regulation not required with the use of the compact x-ray tube and safety enhanced

●Meas. range: 0~0.1wt%0~5wt%

●Automatic analyzer for oil refinery●Measures vapor pressure of petroleum products like gasoline●Vapor pressure is measured by measuring static pressure of the sample that is jetting out from the nozzle at the constant temperature●Measurement result attained via Reid method for vapor pressure

●Meas. range : 0.01~1MPaabs or 0~0.15MPaabs

●Intelligent controller best suited for use with FPA, PPA & CPA●Applicable to multi-stream system, interactive data entry via display & automatic calibration●Self diagnosis, remote control, communication function equipped

●Compatible with TIIS explosion-proof TIIS Expdll BT4 ●Uses environmental friendly Freon replacement gas●Automatic temperature regulation capability by preset temperatures●Onboard safety apparatus, such as overload relay and current overload breaker

●Alternative to existing controller like U-22, U-02 etc.●Easy installlation, using the existing programmer panel cut size●Interactive input by display, auto-calibration, malti-stream support●Self diagnosis, remote control, communication function equipped

Controller

U-221

Explosion-proof type cooler

SCU-02

Controller(for oil product analyzer)

U-32/U-42

Vapor pressure analyzer

DVP-03

Process sulfur content analyzer

SCA-200

Process colorimeter

COL-330

Cloud point analyzer

CPA-21

Boiling point analyzer

BPMFlash point analyzer

FPA

Cold filter pluggingpoint analyzer

CFPPPour point analyzer

PPA

Analyzers for

oil refineries

Environmental/Process analyzers

Page 13: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

10

Water quality analyzers / Systems

●Monitors the environmental water quality of rivers, lakes, and other water bodies and the water quality of effluents, etc.●Built-in automatic cleaning and calibration functions greatly reduce maintenance work●Integrated sensors are employed to reduce unit size and save space

●Measurement itemsWater temperature, pH, electrical conductivity, turbidity, dissolved oxygen

●Outdoor field installation type●Continuous monitoring of fluoride ion concentration by an ion electrode sensor and alarm operated when the preset limit is exceeded●Water-jet cleaning function is available as an option

●Meas. range: 0~99.9/999/9,990mg/L

●Outdoor field installation type●Single-operation calibration with a standard solution is available●Auto determination of electrode deterioration●Automatic electrode error judgment during measurement

●Meas. range: 0.00~9.99mg/L

●Sensor diagnostic function●Next calibration date, sensor sensitivity, dates & times & error information displayed

●Data output by isolated output signal of 4~20mA DC●Equipped with terminals for alarm & under measurement output & remote input ●Highly reliable data attainable with use of thermostat tank

●Meas. range: 0~1,000mg/L (adjustable)

●Compact DIN 96 size unit●Quick and continuous detection of free fluoride ion concentration in sample●Monitors the effluent treatment processes and final effluent from semiconductor factories, etc.

●Meas. range: 0~99.9/999/9,990mg/L

●Sensor diagnostic function●Next calibration, sensor sensitivity,calendar, error information displayed●Data output ; 4~20mA DC, isolatedoutput●Terminal ports for alarm output,meas. output & remote input●Data with high accuracy attainablewith use of thermostat tank

●Meas. range : 0~5mg (free setting)

●Sensor diagnostic function installed●Next calibration date, sensor sensitivity, dates & times & error information displayed

●Data output by isolated output signal of 4~20mA DC●Equipped with terminals for alarm & under measurement output & remote input ●Highly reliable data attainable with use of thermostat tank

●Meas. range: 0~100mg/L(adjustable)

●Compact DIN 96 size unit●Single-operation calibration with a standard solution is available●Auto determination of electrode deterioration●Automatic electrode error judgment during measurement

●Meas. range: 0.00~9.99mg/L

CNBM-100A(panel type)Ammonium ion monitor

NHMS-3Cyanide ion analyzer

CNMS-3

FBM-100A(panel type)Fluoride ion monitor

FMS-3

Simplified cyanide ion monitor

CNBM-160(field installation type)

Simplified fluoride ion monitor

FBM-160(field installation type)

Automatic WaterQuality Monitor

WQMS-CW

●Noncontact & reagentless continuous meas. on BOD of environmental water

●Meas. method: UV-fluorescence method ●Measurement of fluorescence generated by direct ultraviolet irradiation on sample & no reagent required

●Meas. range : 0~10/20mg/L

BOD monitor

BWF-100

Water quality

analyzers /

Systems

Page 14: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

11

Water quality analyzers / Systems

Environmental/Process analyzers

●Measures chemical oxygen demand concentration of river water, lake water and effluent in accordance with JIS (Japanese Industrial Standard) K 0806 “Automatic chemical oxygen demand meter”●Both acid process and alkaline process are selectable●Measurement of 2 flow paths is available(option)

●Meas. range: 1 range arbitrarily selected from 0~20mg/L to 0~2,000mg/L

●Monitoring unit with automated intermittent and continuous measurement method and Diphenylcarbazide Colorimetric Method●Clogging of the electromagnetic valve is prevented using a rotating measurement cell (Japanese Utility Model No. 2137324)●LED used as light source enabling a longer service life for the light source

●Meas. range: 0~0.5/1.0mg/L (Two ranges)

●Reagentless thermal decomposition/chemical luminescence methods●Suitable for measuring seawater samples●Capable of measuring samples including SS●Revolutionary maintenance construction with front-panel operation

●Measurement range: Optional setting ofeither 0~20/50/100/200/500/1,000 mg N/L

●Compact design compliant●Multiple-wavelength detector enables measurement of total nitrogen, total phosphorus and COD(UV)simultaneously●Space-saving design attained by eliminating back piping ●Drip-proof construction●Meas. range: Total nitrogen: 0~2mg/L to 50 mg/L,Total phosphorus: 0~0.5mg/L to 20mg/L,COD(UV): 0~2Abs

●Measures organic pollutant concentration of water by absorbance of ultra violet ray (254nm)method

●Free from fouling and cleaning with fall & flow-through type unit without cell window

●Meas. range : Absorbance:0~0.5/1.0/2.0/2.5

●Oil film is detected by measuring the reflectance of a laser beam projected onto the water surface, due to the difference in the reflectance of oil and water

●Reduction of the influence of broad water surface fluctuations or waviness and suspended solids on the water surface attained using optics-related improvement in light source scanning, etc. and speeding up of signal processing ●No contact made with sample, thus ease of maintenance is attained

●Detectable range: 0.3~3m

●Pollutant integrator calculator that takes in total nitrogen and phosphorousmeas. values as well as valuesfrom COD and UV analyzers.

●Compatible with 1 flow path + 3 analysis and 3 flow paths + 9 analysis●Equipped with printer●Easy to read LCD screen

●Measures organic pollutant concentration of water by absorbance of ultra violet ray (254nm)method

●UV absorptiomatric method employed●No sampling required with direct immersion type detector●Built-in turbidity compensation & self-diagnosis function●Applicable with sampling type unit by attaching receiver tank

●Meas. range : Absorbance : 0~0.5/1.0/2.0/2.5(Auto/manual switching)

●Intrinsically safe explosion proof type

●Oil leakage detected by projecting light laser beam onto water surface & difference between its reflectance to water & oil surface is detected●Signal processing by microprocessor eliminates effect of waving and solids on water surface●No contact made with sample thus ease of maintenance attained

●Meas. object : Oil film on water surface

●Oil film detected by measuring reflected LED light●Peak hold circuit eliminates effect of solid matters that pass through the water surface in subject

●No contact made with sample, thus ease of maintenance is attained

●Meas. object : Floating oil film on water surface

OF-10 SODL-20

OPM-410A

Pollutant integratorcalculator

CALD-2021/2023

ODL-1600

Organic pollution monitor(UV instrument)

OPM-423A

Automatic total nitrogen/phosphorus/COD analyzer

NPW-160

Total nitrogen automaticanalyzer

TNC-250

Hexavalent chromium monitor

CRM-2CAutomatic COD analyzer

COD-203A

Oil-on-water alarms

●Continuously measures oil concentration in industrial effluent without reagent & no contact made with sample

●Over-flow method eliminates need for glass window hence no effects of fouling on cells

●Ease of maintenance attained with no movable part

●Meas. range: 0~2.0mg/L, 0~10.0mg/L

Oil-in-water analyzer

OWF-100

Water quality

analyzers /

Systems

Environmental/Process analyzers

Page 15: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

12

Ambient air analyzers

●US EPA Approval●Chemical luminescence method●Alternating measurement of nitric monoxide(NO)and nitrogen oxides(NOx)ensures stable and continuous measurement of minute amounts of nitrogen oxides in the air●Simple operation with a touch panel screen

●Meas. range : 0~0.1, 0~0.2, 0~0.5, 0~1.0, 0~2.0ppm

Nitrogen Oxides Analyzer

GLN-314E

Emission gas analyzers

●Automatic measurement & recording of methane & non-methane hydrocarbon concentration by gas chromatographic method●Double flow path switching method with use of dummy column

●Meas. range : Instantaneous value/ hourly average value (Saw-tooth graph); 0~5/10/20/50ppm, auto C4 range/manual switching

Ambient non-methanehydrocarbon analyzer

GHC-255

●US EPA Approval●Beta ray attenuation method(mass concentration)●Small and semi-permanent semiconductor detector is used to detect the Beta ray●Calibration film makes calibration easy

●Meas. range : 0~1,000, 0~5,000μg/m3(0~1, 0~5mg/m3)

Particulate Monitor

FPM-222

●US EPA Approval●Gas filter correlation method (IR method)●High sensitivity measurement made possible using multi-reflection cell●Simple operation with a touch panel screen

●Meas. range : 0~5, 0~10, 0~20, 0~50, 0~100ppm

GFC-311E

Carbon Monoxide Analyzer

●US EPA Approval●UV photometry ●Simple operation with a touch panel screen

●Meas. range : 0~0.1, 0~0.2, 0~0.5, 0~1.0ppm

GUX-313EOzone Analyzer

●US EPA Approval●Ultraviolet fluorescence method ●Improved optical system reducesthe impact from interfering substances●Simple operation with a touch panel screen

●Meas. range : 0~0.05, 0~0.1, 0~0.2, 0~0.5, 0~1.0ppm

GFS-312E

Sulfur DioxideAnalyzer

●Calibrator for SO2, NOX, CO analyzers●Built-in zero gas generator enables suction of ambient air & purification into zero gas ●Concentration of span gas (calibration) is freely adjustable between 1:100 &1:10,000 of component gas concentration

Calibration gasstandards generator

CGS-12

●No warm-up time, little temperature effect and stable ozone output by using frequency controlled pulse xenon lamp

●Zero gas cylinder not required as zero gas generator uses ambient air as resource gas●Linearity test easily attainable with 5 division function ●Easy to carry potable type

Ozone generator forozone analyzer

OZ-200/202

●CO sensor with electric electrolysis method & sensor with galvanic batteries●Ease of maintenance, cost reduction attainable with simply constructed unit

●Meas. range: CO2; 0~200 to 2,000ppm (setting available at 100ppm intervals)(selectable), O2; 0~25%

Flue gas CO,O2 analyzer

GCO-200

●Continuous measurement of flue gashydrogen chloride concentration produced in incineration plants by ion electrode method●New small size chloride ion electrode and auto-cleaning function equipped

●Easy installation and maintenance attained with front panel operation

●Meas. Range : 0~(50~2,000)ppm,        0~(10~50)ppm,(option)

Flue gas hydrogenchloride analyzer

GNC-224-1

Ambient air

analyzers

Emission gas

analyzers

Page 16: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

13

pH meter

Laboratory analyzers

Analytical instruments

●Easy-to-read LCD display type●AC/DC 2-way power source●ORP measurable●mV shift function●Inexpensive & compact size●Meas. range: pH0.00~14.00, 0~±1,999mV

●Easy-to-read analog display type meter with mirror(Enlarged scale) ●AC/DC 2-way power source●ORP measurable●mV shift function●Inexpensive & compact size●Meas. range: pH0~14, 0~±1,400mV

●GLP/Part 11 conformity●Built-in pure water temperaturecompensation●Measures and records the ambient temperature/humidity (option)

●USB(Host), LAN standard equipment ●Suitable for USP measurement●Meas. range: 0~200.0 S/m 0~20.00 MΩ・m , Chloride 0~4.00%Concentration 0~200% , 0~100.0℃

●2-Channel model with automatic sensor identification●Possible pH/ORP/ion/conductivity/ dissolved O2 sensor connection to either channel●GLP/Part 11 conformity●0.01/0.001 pH switching display available ●Large color graphic LCD display●Measures and records the ambient temperature/humidity (option)

●USB(Host), LAN standard equipment

●Easy-to-read LCD display type●AC/DC 2-way power source●SI unit(S/m) & (S/cm) selectable●Inexpensive & compact size●Meas. range: 0~20.00S/m

●Low-cost basic model●Easy-to-read large customized LCD display●External printer connection●Data memory function 300 points ●Suitable for USP measurement●Meas. range: 0~200.0 S/m 0~20.00 MΩ・m Chloride 0~4.00% , 0~100.0℃

●External printer connection●Multiple samples measurement (turntable connection) available●Data memory function 300 points ●Meas. items: pH, ORP, Electric Conductivity, Resistivitiy, Salt, ion, temp. , DO, Sat.rate

Conductivity meter

Multi-function water quality meter(pH/ORP/Ion/Conductivity/Dissolved O2)

●R series Low-cost basic model●Easy-to-read large customized LCD display●Uses high-performance, Strong and Float (internal solution concentration checker) pH electrodes●External printer connection●Data memory function 300 points ●Meas. range: pH 0.00~14.00

0~±2,000mV(electrode sold separately)

0~100.0℃

●GLP/Part 11 conformity●0.01/0.001 pH switching display possible●High-performance, Strong and Float (internal solution concentration checker)pH electrodes●Measures and records the ambient temperature/humidity(option)

●USB(Host), LAN standard equipment●Multiple samples measurement (turntable connection) capability●Meas. range: pH 0.000~14.000

0.0~±2,000.0mV(electrode sold separately) 0~100.0℃

HM-30R HM-7JHM-20JHM-25R

CM-30R CM-25R CM-20J

MM-60R

Analytical instruments

Laboratory

analyzers

Page 17: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

TA-70 TS-70 TP-70

14

Laboratory analyzers

●Accurate dispensing (setting volume/ constant speed injection) available

●Used as titration burette for manual titration

●GLP compliance●Sampling mode loaded (meas/dilution)

●RS-232 equipped as standard specification

●Simplified and dedicated series of titrators

●Electrodes for trace amount titration

●Connectable to turn table●External printer(option)

●Dual system (2-chanel simultaneous titration)

●Strong pH electrode with float inner solution concentration checker, electrodes for trace titration, other high performance electrodes●USB (host) and LAN●Validation supporting function●Connectable to turn table, auto-sampling system, etc.

●Simple pretreatment●Simultaneous measurement of 5 kinds of sugar and ethanol, or 7 kinds of sugar alcohol●Automatic analysis and calculation without PC

●Front operation makes maintenance easy●Auto-sampler (option)

●Compact main unit holding up to 3 pumps and 2 detector units●Simple system expansion by optional combined pump-detector unit installation●Remote data monitoring capability due to LAN based main unit/PC control signal connection

●6 cations or 7 anions simultaneous measurement●Simple and easy-to-operate for any user - results are automatically analyzed and calculated internally●Results are displayed on the display panel and printed out by the printer unit●Suppressor method available for anion measurements

●Measurement items: Anions: PO4, F, Cl, NO2, Br, NO3, SO4Cations: Li, Na, NH4, K, Mg, Ca

●PC linked pos+ / neg- ion 2-channel real-time chromatograph data display/report printout●High sensitivity analysis by chemical suppressor system

Ion analyzer

IA-300

Salt analyzer

SAT-500

Ion chromatograph

ICA-2000 Series

Sugar analyzer

SU-300

Automatic titrator

AUT-701Acidity meter/Salinity meter/Potentiometric titrator

TA-70/TS-70/TP-70Auto burette

ABT-511

Chemical suppressorsystem

●Measurement of bacteria & cell in 50 sec.●Highly sensitive measurement of 1~1000 cells./mL●Direct measurement of membrane filter●Compliance with sanitary management by swap test●Handy functions like ATP concentration & cell converted value available ●Auto injector of somatic cell’s reagent (option)

ATP analyzer

AF-100

●Oxidation & titration processing functions unified to form measurement section●Easy operation by automation of oxidation & titration ●Smaller waste solution 10mL/measurment ●Real time display of sequence and titration curve

●Meas. range: 0~20.0/40.0/100/200/400/1,000mg/L

Simplified COD meter

COD-60A

●Simple operation - Just injects sample into electrolyte in dedicated beaker ●Rapid measurement - approx. 25 seconds from measurement start to data output for a standard 1% NaCl standard solution●Capable of stable measurements without effect from artificial colorings

●Meas. Range % display : 0.0000~49.99%

●Post column reactor using non-metal pump available

Laboratory

analyzers

Page 18: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

15

Portable & handheld analyzers

Analytical instruments

●Display of salinity (NaCl) is available (CM-31P)●Highly accurate measurement in pure water attainable with the pure water temperature compensation function (CM-31P-W)

●Power-saving design, usable rechargeable batteries●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)

●Meas. range (when a standard cell is used): 0.1mS/m~10S/m0.1Ω·m~10kΩ·mSalinity: 0~4.00%, 0~80℃

●DO electrodes for incubator bottles and stirring-free DO electrodes available(options)●Power-saving design, usable rechargeable batteries

●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)(except for the DO electrode for incubator bottles)

●Data storage function (1,000 data points)●Meas. range: 0~20.00mg/L (0-50.0 mg/L*)0~200% (0~500%*)* When the high-concentration membrane set (optional) 0~50℃

●Exclusively for ORP (Oxidation-Reduction Potential) model●Power-saving design, usable rechargeable batteries●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)●Data storage function (1,000 data points)

●Meas. range: 0~±2,000mV 0~100.0℃

●Popular type, exclusively pH measurement (HM-30P)●Sophisticated type, capable of pH and ORP measurement (HM-31P)●Power-saving design, usable rechargeable batteries●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable) ●Data storage function (1,000 data points)

●Meas. range: pH: 0~14 (HM-30P/31P)0~100.0℃ (HM-30P/31P)0~±2,000 mV (HM-31P) (ORP electrodes sold separately)

●Two-channel type, simultaneous measurement and display of DO/pH●Power-saving design, usable rechargeable batteries●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)●Data storage function (1,000 data points)●PC and external printer connectable●Measurement items: pH, ORP (ORP electrodes sold separately), DO, temperature

Hand-held Ion/pH meter

IM-32P(Ion electrodes sold separately)

Hand-held DO/pH meter

DM-32P

Hand-held Electric Conductivity/pH meter

WM-32EP

Hand-held pH meter

HM-30P/31PHand-held ORP meter

RM-30PHand-held DO meter

DO-31P

Hand-held Electric conductivity meter

CM-31P(for standard use)/CM-31P-W(for pure water)

●Meas. by dipping the sensor into sample like rivers, dams & waste water available

●Depth of up to 100m measurable by optional electrode●NTU or mg/L unit for display selectable●AC/DC 2-way power source●Meas. range : 0~800NTU or 800mg/L, 0~50.0℃

●11 items measurable i.e. total nitrogen & phosphorus●Blank calibration function●Up to 1000 data memory●Built-in printer●Meas. items: TN, TP, COD

PO4-P, PO4NO3-N, NO3NO2-N, NO2NH4-N, NH4

●Easy meas. of 6 items (pH, temp., DO, conductivity, turbidity, salinity)●Useful for applications like rivers, lakes, dams, etc●Easy maintenance with cartridge electrode●Meas. at depth of 30m available by optional electrode●AC/DC (batteries) 2-way power source

●Simultaneous meas. of up to 11items (pH, DO, conductivity, turbidity, temp., salinity, Total Dissolved Solid, specific gravity of sea water, water depth, ORP, chlorophyll, Ions (F-, Cl-, NO3-, Ca2+, K+, NH4+ ) )●Continuous meas. at depth of 100m available●Diameter of std. sensor module is 45mm●Data storage of up to 1 month

Multi-parameterwater quality meter

WQC-24Water quality checker

WQC-22A

Portable total nitrogen/phosphorus meter

TNP-10Portable turbidity meter

TB-25A

Analytical instruments

●Two-channel type, simultaneous measurement and display of pH/conductivity●Power-saving design, usable rechargeable batteries●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)●Data storage function (1,000 data points)●PC and external printer connectable●Measurement items: pH, ORP (ORP electrodes sold separately), conductivity, resistivity, salinity, temperature

●Two-channel type, simultaneous measurement and display of pH/ions●Power-saving design, usable rechargeable batteries●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)●Data storage function (1,000 data points)●PC and external printer connectable●Measurement items: pH, ORP, ions, temperature (ORP electrodes and ion electrodes sold separately)

Portable &

handheld

analyzers

Page 19: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

16

Portable & handheld analyzers

●Acid & alkali concentration can be measured●High concentration range can be measured by electromagnetic method●Analog output equipped, available easy continuous measurement●Switchable between concentration & conductivity rate●Ease of maintenance & no daily calibration required

●Meas. range(conductivity rate): 0~200S/m

●Portable type, Easy calibration by Air & continuous meas.

●2 types available; OZ-20 (for liquid phase) & OZ-30 (for gas phase)●Easy measurement, simply by placing electrode in the atmosphere●Suitable for monitoring with its high stability●AC/DC(batteries) 2-way power source●Optional flow cell for dissolved ozone

●Meas. range : 1.5~19.99mg/L(for liquid), 1~100g/m3(for air)

Portable ozone meter

OZ-20/30

●Direct meas. of CO2 concentration in both liquid phase & gas phase by adoption of membrane type electrode method●Portable type for field measurement●Small sample measurement available for easy maintenunce●Cartridge type membrane●AC/DC(batteries) 2-way power source

●Meas. range : 0.03~19.99%F.S.

Portable carbon dioxidemeter

CGP-1

Portable electromagneticanalyzer

MDM-25A(Including of PVC sensor)

●Fast response with membrane type polarographic electrode

●Highly sensitive measurement with μg/L●Atmospheric calibration method & hydrogen std. gas not required●AC/DC batteries 2-way power source●Equipped with flow-through cell & analogue output cable(std.)

●Meas. range: 0.0ppb~10.00ppm

Portable dissolved hydrogenmeter

DH-35A

Low density dissolved oxygen meter

DO-32A

●Simple method for checking surface salinity prior to painting for ships, etc

●Easy operation ; Place the meas. cell on the steel surface and inject pure water into the meas. cell

●Meas. range: 0~199.9mg/m2, 0~1,999mg/m2

0~199.9μS/cm, 0~1.999mS/cm0~50℃

Hand-held surface salinity meter

SSM-21P

●Simple, reagent-free measurement of stream water ozone concentration of the ozone water generator●Water proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)

●Beads polishing method adopted to give stable measurements

●External printer connectable and RS-232 output

●Measurement range: 0~2.00 mg/L, 5~40℃

Portable dissolvedozone meter

OZ-21P

●Measures diluted sodium hypochloric acid concentration without reagent

●Stable measurement attainable with use of bead polishing method, enabling constant cleaning of the electrodes●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)

●Meas. range: 20~300mg/L5~40℃

Hand-held hypochlorite concentration analyzer

RC-37P

●Polarographic method adoptedResidual chlorine in tap water, swimming pool water, etc. measurable without using a reagent, with low running cost and ease of operation●Container and Throw-in Sensor Type and Flowing Sensor Type are available●Water-proof construction (IP67: Immersion of 1 m depth and 30 min duration is allowable)

●Meas. range: 0~2.00 mg/L0~45℃

Hand-held residual chlorine meter

RC-31P

●Measurable fromμg/L(ppb) to 20mg/L(ppm)●Auto-ranging and continuous meas. available●Small & easily operated flow cell●AC/DC batteries 2-way power source●Meas. range: 0.00~19.99μ/199.9μ/1.999m/19.99mg/L F.S.(4 ranges), 0~45℃

Portable &

handheld

analyzers

Page 20: Process analyzers Analyzers for boiler water applications ... Short Form Catalog 2010… · Process analyzers Analyzers for water & waste water treatment Analyzers for boiler water

E2-5-30EIssued on 12/7/2010