product catalog(flow meter)
TRANSCRIPT
-
7/29/2019 Product Catalog(FLOW METER)
1/6
Water Gases
Oil
OUR
PRINCIPALS
Strainer
OVAL JAPANITRONSure flow-japanGreentech Japan
Ashlin Enterprises.Zenner Aqua met.B-MeterKENT
POINTERROTRONICGWFE&H
A water meteris a deviceused to measure the volumeof water usage. water metersare used to measure thevolume of water used byresidential and commercialbuilding that are supplied withwater by a public watersupply system.
A gas meteris usedto measure the volume of fuelgases such as naturalgas and propane. Gas metersare used at residential,
commercial, and industrialbuildings that consume fuelgas supplied by a gas utility.
Oil meters used for thispurpose can measure andrecords the flow precisely. Oilmetering is essential forwidespread areas likeindustrial usage, automotiveusage and marine. Ourproducts provides you withthe advanced quality control
Zest ENGINEERING
A device through which aliquid is passed forpurification, filtering orseparation from solid matter;anything any devicefunctioning as a sieve or filter- in special, a perforatedscreen or openwork (usuallyat the end of a suction pipe ofa pump), used to preventsolid bodies from mixing in aliquid stream or flow line.
www.zestengg.co.in [email protected]
-
7/29/2019 Product Catalog(FLOW METER)
2/6
Pulse Output Water Meter
A
B
DOMESTIC WATER METER
(HOT &COLD)SINGLE JET/MULTI JETclass A & Class B .
size(15mm to 50mm)
FEATURES
Cold water 0-30C
Hot water 30-90CMax working pressure 5 barMechanical transmission. Direct reading by numerical rolls. Low Head Loss
(HOT &COLD)SINGLE JET/MULTI JETclass A & Class B .size(15mm to 500mm)
FEATURES
Cold water 0-30C
Hot water 30-90CMax working pressure 16 barMechanical transmission. Direct reading by numerical rolls. Low Head Loss
Woltmann Type Water meters
(HOT &COLD)Woltmann Water meterclass A & Class B .size(50mm to 500mm)
FEATURES
Cold water 0-30C
Hot water 30-90CMax working pressure 16barMechanical transmission. Direct reading by numerical rolls. Low Head Loss
Electromagnetic flow meter
www.zestengg.co.in [email protected]
Electromagnetic flow meter, composed of sensor andconverter, works based on Faraday's law ofelectromagnetic induction. It is used to measure electrical
conductivity of liquid or solid. Generally, the electricalconductivity should be over 5uS/cm (electrical conductivityof tap water, raw water is about 100-500uS/cm.It can alsobe used to measure various mediums like acid, alkali,saline solution, paper pulp, ore pulp and so on, but thesemediums can't contain a lot of magnetic materials and
Size-Dn15 - Dn1000ElectrodeMaterial-316L,Hc,Hb,Ti,Ta
LinerMaterial-Neoprene,PTFE,PFA,F46
Conductivity-GreaterorEqual5s/cm
Accuracy-+/-0.5%ofthevaluedisplayed
Protection Class - IP65, IP67
Measuring Range-0.2 ~ 28000 m3/h
Pow. Supply - 3.6 V lithium battery.
Type- Flange type /Inserted type / Batteryoperated/ Integral type/ Triclover Type.
ApplicationEffluent Treatment Plants
Water Supply Schemes
Food & Drug Industry
Dairy Industries
Corrosive Liquids
SugarIndustry
ZEST
-
7/29/2019 Product Catalog(FLOW METER)
3/6
Specification
A B
D C
Size: 4~20
Temperature:-20C~120C
Output:4~20mA DC and Pulse(Standard)
Accuracy:+/-1.0%
Connection: Screwed or Flange
Power Supply AC 85~230V, 50/60Hz or DC 24V or Battery (3 year)
Operating Temperature -20 ~ 120 Deg C
Ambient Temperature -20 ~ 50 Deg C
Accuracy 1.0 %, 0.5%
Output Signal 4~20mA DC and Pulse (Standard)
Display LCD 2 Line x12 character (Rate Flow /Total Flow)
Service Clear Liquid, Gases ,Air, solvent.
Flange Screwed and Flange (As per standard)
Enclosure IP67,IP65
LIQUID TURBINE FLOW METER
Turbine Flow meter
www.zestengg.co.in [email protected]
-
7/29/2019 Product Catalog(FLOW METER)
4/6
A
B C
Gas Turbine Flow Meters
Specifications
Material: Stainless Steel/Aluminum
DN range (mm): DN15-DN200
Output: Pulse/current4-20Am/RS-485
Accuracy: 0.5% / 1%
Operating Pressure Max - 6 barFlow range (m / h): 1.0-3600
Power supply: 220VAC / 24VDC
Medium temperature (centigrade): -30-65
Ambient temperature (centigrade): -20-80
Atmospheric pressure: 86-106KPa
Nominal Pressure: 1.6, 2.5, 4.0, 6.4MPa
Application
InternalmeasurementCoalGas
LiquefiedGas
LighthydrocarbonGas
Petroleum,chemical
Industries
SewerGas
Turbine gas meters infer gas volume by determining
the speed of the gas moving through the meter.
Diaphragm Type flow METERS
Features: 1) High sensitivity,
2) high accuracy 3) Good stability and
reliability 3) Low maintenance
4) Digital Display.5) Pulse Out put.
6) Avaible-G1.6/G4G16
Technical specifications:
1) Nominal flow rate: 1.6, 2.5m3/h2) Maximum flow rate: 2.5, 4m3/h3) Minimum flow rate: 0.016, 0.025m3/h
4) Operating pressure range: 0.5 ~ 3kPa5) Accuracy: B grade
6) Basic error limit: QminQ
-
7/29/2019 Product Catalog(FLOW METER)
5/6
OIL Meters
Easy to connect with previous systems due to its high compatibility .
Indication through 8-digit LCD display
Wide range of flows and maintaining of high level of accuracy
Easy to install due to its dimension conforming to previous products.
Monitoring Oil Consumption
Pressure, temperature and viscosity options
Flow Rate 10 Lt/ Hr - 48M3/ Hr
Temperature Upto 150o
C
Pressure 0-21 Kg/ cm2
(Optional 40 Kg/ cm2)
Viscosity 1000 CP maximum
Accuracy Within +(-) 0.5% (Optional +(-) 0.2%Nominal Bore
Size 15 mm, 20 mm, 25 mm, 40 mm, 50 mm, 80 mmLiquids Petroleum Products (MS, HSD, SKO, LDO, FO, LS
OutputTotalisation of flow (Mechanical Counter) Optional Electronics
Application
Specification
Oval gear positive displacement technologyAccuracy +/-0.5% on pulse models,+/-1% on mechanical Suitable for lubricant,
fuels and chemicals.Available for flow ranges from 2 to 1200
litres per minutePipe sizes from 1/2" to 4" with BSPand flange connections
Mechanical and electronic display options
Pulse output and 4~20mA output models
Multiple construction material options
Pressure, temperature and viscosity options
LC Series oval gear oil flow meter, the main type of positive displacement flow meters
is used to measure pressure in the pipeline closed under full pipe flow of the fluid flow.
It has good adaptation and essentially unregulated measuring temperature, pressure change
and easy of installation.
OvalGearFlowmeter
Application
Petroleum
Chemical
Medicine
Shipping
FoodSyrup
GreasesCommercial departSolvent
ZEST
Type of StrainerSimplex Basket
StrainersDuplex BasketStrainersY Type StrainersT Type StrainersTemporary StrainersBag Filters
STRAINER
M.O.C. Housing
Casted - C.I./C.S./S.S./G.M.
Fabricated- M.S./S.S/P.P. Fiber/others onrequestElement- SS 304/SS, 316/Brass, Paper,
Sintered.
Size RangeCasted - NB to 1 Screwed, BW,SW
NB to 8 Flanged
Fabricated- NB to 4 Screwed
NB 1 to 60 Flanged
Application
Pumps
Engines
Flow meter
Boilers
Turbine
RO Plants
www.zesteng.co.in [email protected]
Oil flow meters areapproved by Government
of India, Department ofLegal Metrology (Weights
& Measures).
-
7/29/2019 Product Catalog(FLOW METER)
6/6
ZEST ENGINEERING
DE-58, SECTOR-3,INDUSTRIAL AREA- BAWANANEW DELHI- 110039INDIACalls Us -+91-8800445945Land line- [email protected] us-www.zestengg.co.in
RTD/Thermocouple
RTDs may be purchased with 2, 3, or 4 lead wires
Extending from the sensor. In determining the
number of wires, consideration of the following is
Important:
Required accuracy
Stability
Receiving device location
Corrosion potential - environmental
conditions
Nominal sensor range and resistance
SpecificationsRTD type thermocouple,
Industrial thermocouple,
1.J, S, K, PT100 type
2.water-proff/explosion-proof
Pressure Gauges Type of Pressure Gauge
Normal Pressure Gauges
Oxygen Pressure GaugesVibration Free PressureGauges
LPG Pressure Gauges
CNG Pressure Gauges
Specification
Dial Size : 2 ", 4", 6" , 8", 10"
Case & Bezel : SS 304/ Die Cast Aluminum Weather Proof
Pointer : Micro Zero or center zero adjustable
Bourdon Material : SS 316/Brass
Socket Material : SS 316/Brass
Entry : Bottom Back
Mounting : Direct, Panel, SurfaceConnection : ", 3/8", ", " and 1" BSP, NPT, Metric threa
Male/Female, adj./fixed
Accuracy : + 1% of F.S.D.
Over Range Protection : 125 % of F.S.D.
Valves
Type of Valves
Gate Valve
Ball Valve
Sluice gate valve
Check Valve
Safety Valve
Check Valve
Butterfly Valve
A valve is a device that regulates, directs or controls the flow of a fluid
(gases, liquids, fluidized solids, or slurries) by opening, closing, or partially obstructing various passag
TypeofPipes
Sanitation System Pipes
Plumbing System PVC Pipes
Agriculture System PVC PipeSales office.
ZEST ENGINEERING
RAJAN NIWAS, NEAR M.C.OFFICE, RAJGARH ROAD.
SOLAN (H P)
Pin Code - 1732132Phone- [email protected] us-www.zestengg.co.in
Wehavetherighttomodifytheabovewrittenwordswithoutanynotice.
Sales OfficeZest Engineering162,Sarla BaghDayal BaghAgra282005Phone-9997098945