product catalogue · indicator ink which color changes after steam sterilization process. class 5...

14
PRODUCT CATALOGUE İvedik OSB , Ağaç İşleri Sitesi 1358. Sk. No: 30 Yenimahalle, ANKARA / TURKEY T. +90 312 562 02 21, +90 312 562 02 22 - F. +90 312 562 02 19 www.nkmedica.com - [email protected] www.nkmedica.com

Upload: others

Post on 23-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

  • PRODUCT

    CATALOGUE

    İvedik OSB , Ağaç İşleri Sitesi 1358. Sk. No: 30 Yenimahalle, ANKARA / TURKEY

    T. +90 312 562 02 21, +90 312 562 02 22 - F. +90 312 562 02 19

    www.nkmedica.com - [email protected]

    www.nkmedica.com

  • Necati Kaya Medical Devices has been operating in the

    medical device industry for over 35 years and continues its

    commercial activities under the direction of chemical engineer

    Necati Kaya. While the production center in Ankara Ivedik OSB

    produces STERISTAR branded sterilization control products in

    ISO 9001 and ISO 13485 standards, the company's import

    department imports the highest quality products from abroad

    from reputable companies as the sole authorized

    representative of Turkey.

    STERISTAR branded products are exported with high

    customer satisfaction to more than 45 countries. from our new

    production facility, 95% of the production processes at high

    quality standards are done by ourselves and in our new test

    laboratory, the quality controls of the products are regularly

    performed and recorded in accordance with the obligations of

    the quality system. Our company continues to work with the

    values, integrity and quality principles that our president

    Necati Kaya gives to people.

  • www.nkmedica.com

    “Produced in Turkey sold to world...”

    WE ARE EXPORTING TO

    45 COUNTRIES WORLDWIDE,

    81 CITIES IN TURKEY

  • Ref# Description Packaging

    SAT 1950 Steam Tape 19 mm x 50 M 60 pcs / Carton

    SAT 2550 Steam Tape 25 mm x 50 M 50 pcs / Carton

    E-1950 EO Tape 19 mm x 50 M 60 pcs / Carton

    60 pcs / Carton

    50 pcs / CartonE-2550 EO Tape 25 mm x 50 M

    50 pcs / Carton

    60 pcs / Carton

    H-1950 H2O2 Tape 19 mm x 50 M

    NPT-1950 Non-printed Tape 19 mm x 50 M

    NPT-2550 Non-printed Tape 25 mm x 50 M

    Autoclave Tapes

    · Compatible with ISO 11140-1

    · Water-based and non-toxic chemical indicator

    · Different sizes are available on request.

    A reliable autoclave tape that provides immediate identification of processed items and also serves as a closure tape to seal sterilization packs. The chemical indicator lines will turn dark when exposed to proper sterilization conditions. The autoclave tapes are suitable for steam and ethylene oxide sterilization processes.

    · Adheres to woven, treated woven, non-woven, paper and paper/plastic wraps

    · Adhesive seals pack the wrapping material securely but provide a clean peel from the material

    It is important to note that the presence of autoclave tape that has changed color on an item does not ensure that the product is sterile, as the tape will change color upon exposure only.

    Bowie & Dick Test Packs

    · Bowie-Dick test packs make testing steam penetration and air removal, as well as detecting air leaks, more convenient and cost effective

    · Designed to give equivalent results to those obtainable by the Bowie and Dick protocol

    Performed after a warm-up cycle at the beginning of every day, the Bowie-Dick Test verifies the sterilizer effectively removes air.

    · Compatible with ISO 11140-4 (Class 2 + 4)

    · Different designs are available on request

    · Water-based and non-toxic chemical indicator

    National and International Standards demand that vacuum-assisted steam sterilizers must be tested at the beginning of each working day. “Bowie & Dick Test Pack” concept allows you to fulfill this requirement with minimum effort and with the highest level of quality.

    · Indicator pattern is easy to read and interpret

    · The backside of the indicator sheet contains fields to be filled out and it can be kept as a permanent record for traceability purposes

    Test Pack designed for vacuum-assisted sterilizers to test the efficiency of the vacuum system, to remove air from the sterilizer chamber and to detect leaks in the system that would allow air into the chamber. A uniform change of the indicator sheet indicates that all the air was removed and replaced by steam.

    Ref# Description Packaging

    BD-200 Bowie&Dick Test Pack (200 Sheets) 80 pcs / Carton

    BD-200W Bowie&Dick Test Pack Wrapping (200 Sheets) 100 pcs / Carton

    BD-400 Bowie&Dick Test Pack (400 Sheets) 48 pcs / Carton

    BD-400W Bowie&Dick Test Pack Wrapping (400 Sheets) 52 pcs / Carton

    BD 200

    BD 200W

    H-1950

    E-1950

    SAT 1950

    NPT 1950

    Clean/Decontaminate Store Issue/Use

    Prep/Pack Sterilize Clean/Decontaminate Store Issue/UsePrep/Pack Sterilize

  • Helix PCD Test (process challenge device) is used as a daily test for pre-vacuum hospital sterilizers and for bench

    top steam sterilizers Class B for steam penetration and inert gases. The Helix PCD test is an excellent test to

    detect even the smallest amounts of inert gases and steam penetration capabilities.

    · 250 cycles are guaranteed

    · After EO Sterilization process blue color changes to green color

    · Compatible with ISO 11140-1

    The EN 867 Part 5 is describing a Helix PCD based steam penetration test as an alternative for the Bowie & Dick

    Test for bench top steam sterilizers Class B the EN 285 is specifying the Helix PCD test for hospital steam

    sterilizers when it is mainly used to sterilize hollow loads.

    Helix PCD test is not replacing routine monitoring of sterilization cycles. This should be done by lot control sets

    and/or with in pack integrators.

    There are different types of indicator according to the sterilization process selected: Steam, Ethylene Oxide and

    Hydrogen Peroxide. If the all bars change to the final color, the result is successful, so the sterilizer is working

    correctly. If one bar is different to the final color, it shows a bad sterilizing agent penetration, therefore an

    equipment malfunction.

    · Water-based and non-toxic chemical indicator

    · It is easy to read and interpret

    · After Steam Sterilization process pink color changes to dark color

    · After H2O2 Sterilization process purple color changes to blue color

    · With the self-Adhesive feature it can be used as a permanent record for traceability purposes

    Helix Test PCD and Apparatus

    Ref# Description Packaging

    -

    -

    50 pcs / Carton

    50 pcs / Carton

    C-1031 HELIX PCD TUBE 1.5 M

    C-1131 HELIX PCD TUBE 80 CM

    C-1030 STEAM PCD Test Helix, Self Adhesive, 4 Indicators (Pack of 250)

    C-1032 STEAM PCD Test Helix, Self Adhesive, 6 Indicators (Pack of 250)

    C-1033 STEAM PCD Test Helix, Self Adhesive, 4 Indicators, Big Scale (Pack of 250)

    C-1045 EO Gas PCD Test Helix, Self Adhesive, 4 Indicators (Pack of 250)

    C-1048 H2O2 PCD Test Helix,Self Adhesive, 4 Indicators (Pack of 250)

    50 pcs / Carton

    50 pcs / Carton

    50 pcs / Carton

    C-1030 PCD C-1032 BD

    C-1033 C-1045

    C-1048

    C-1031

    Helix Test PCD and Apparatus Clean/

    Decontaminate StorePrep/Pack SterilizeClean/Decontaminate Store

    Prep/Pack Sterilize Issue/Use Issue/Use

  • Class 4 Dual Strips

    Class 4 Dual Strips monitors critical parameters to ensure proper sterilization has accrued during the steam

    sterilization process. The Dual Strips designed for use in all steam sterilizers. Long stripe of chemical indicator ink

    printed on perforated-style strip allows full- or half-length use for different pack sizes. For rigid sterilization loads

    there should be at least 2 test strips diagonally opposite in each corner to ensure that the cycle has reached all

    areas of the machine.

    · Water-based and non-toxic chemical indicator

    · Compatible with ISO 11140-1

    · Class 4 Dual Strips are cost effective and can be divided into two separate pieces for economical use

    · Self-Adhesive versions are available on request

    · It is easy to read and interpret

    · Self-Adhesive versions can be used as a permanent record for traceability purposes

    Ref# Description Packaging

    C-1040 Class 4 Steam Dual Strip (250 x 2) 60 pcs / Carton

    C-1040-SA Class 4 Steam Self Adhesive Dual Strip (250 x 2) 50 pcs / Carton

    Pink Card Bowie & Dick Test

    · It is easy to read and interpret

    The Pink Card is a Bowie-Dick test designed to detect air leaks, inadequate steam penetration and vacuum pump

    failures in pre-vacuum steam sterilizers. The test is conducted each day in an empty sterilizer prior to processing

    any loads.

    · Compatible with ISO 11140-1 and EN 867-5

    · Water-based and non-toxic chemical indicator

    · The apparatus of the Pink Card (metal ring) allows Pink Card to be attached to a rack in the sterilizer and holds

    the card in place during the sterilization cycle

    Ref# Description Packaging

    50 pcs / CartonBD-8 Pink Card Bowie & Dick Test, (Pack of 100)

    BD-8 HLD Holder for BD-8 Pink Card -

    BD-8 C-1040

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/PackClean/Decontaminate Store Issue/Use

    Prep/Pack Sterilize Issue/Use

    BD-8 HLD

  • Class 5 Extender

    · Moving front style has accept/reject readout for instant results without interpretation, convenient small size

    for all packs

    · Safe, non-toxic chemicals; no risk for contamination or transfer of sterile items

    Class 5 Extender can be used inside each load to monitor time, temperature, and steam exposure conditions and

    can provide the necessary sterilization assurance. The Extender consists of two parts, Class 5 Steam Integrator

    and Class 5 Integrator. Class 5 Steam Integrator consists a paper wick and a steam and temperature sensitive

    chemical pellet contained in a foil laminate. The chemical pellet melts and migrates as a dark color along the

    paper wick. The migration is visible through a window marked as REJECT or ACCEPT. Class 5 Integrator consists

    indicator ink which color changes after steam sterilization process. Class 5 Extender can provide the enhanced

    confidence about the success of the sterilization process due to the double check feature.

    · Compatible with ISO 11140-1

    · Different designs are available on request

    · Two window or one window option is available on request

    · Available for steam sterilization cycles

    Ref# Description Packaging

    50 pcs / Carton

    25 pcs / Carton

    -C-1604 Class 5 Integrator with Ext. (pack of 100)

    C-1604 Class 5 Integrator with Ext. (pack of 250)

    C-1604 Class 5 Integrator with Ext. (pack of 500)

    Class 5 Steam Integrator

    · Moving front” style has accept/reject readout for instant results without interpretation, convenient small size

    for all packs

    · Compatible with ISO 11140-1

    Class 5 Steam Integrators can be used inside each load to monitor time, temperature, and steam exposure

    conditions and can provide the necessary sterilization assurance. Class 5 integrator mimics the ability of a

    biological indicator at three separate and distinct points during the sterilization process, because it will monitor

    both time and temperature without requiring incubation as does a biological indicator. The Integrator consists a

    paper wick and a steam and temperature sensitive chemical pellet contained in a foil laminate. The chemical

    pellet melts and migrates as a dark color along the paper wick. The migration is visible through a window marked

    as REJECT or ACCEPT.

    · Different designs are available on request

    · Available for steam sterilization cycles

    · Safe, non-toxic chemicals; no risk for contamination or transfer of sterile items

    · Two window or one window option is available on request

    Ref# Description Packaging

    C-1005 Class 5 Steam Integrator (pack of 100) -

    -

    C-1005 Class 5 Steam Integrator (pack of 250) 50 pcs / Carton

    C-1005 Class 5 Steam Integrator (pack of 500) 25 pcs / Carton

    C-1603 Class 5 Steam Integrator (pack of 100)

    C-1603 Class 5 Steam Integrator (pack of 250)

    C-1603 Class 5 Steam Integrator (pack of 500)

    50 pcs / Carton

    25 pcs / Carton

    C-1005

    C-1063

    C-1604

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/Pack Issue/UseClean/Decontaminate Sterilize StoreSterilizePrep/Pack Issue/Use

  • Class 5 Integrator

    The Class Integrator is designed to evaluate parameters of the sterilization process on the location and to give

    instant read-out. It can be used in all steam sterilizers as an internal pack monitor. The Integrator changes color

    rapidly when the sterilization parameters are reached. An internal chemical indicator should be placed in every

    sterilization package to ensure the sterilization agent has penetrated the packaging material and reached the

    instruments inside.

    · Water-based and non-toxic chemical indicator

    · Compatible with ISO 11140-1

    · Multiparameter and single parameter options are available on request

    · It is easy to read and interpret

    · Self-Adhesive versions are available on request

    · Different designs are available on request

    · Self-Adhesive versions can be used as a permanent record for traceability purposes

    Ref# Description Packaging

    60 pcs / Carton

    Class 6 Emulating Indicator

    · Self-Adhesive versions can be used as a permanent record for traceability purposes

    · Different designs are available on request

    · Water-based and non-toxic chemical indicator

    · Self-Adhesive versions are available on request

    · Multiparameter and single parameter options are available on request

    · It is easy to read and interpret

    Class 6 Emulating Indicators are cycle verification indicators that confirm the presence or absence of specific time

    and temperature parameters during a cycle and integrate all the critical parameters of the steam sterilization

    cycle. Emulating indicators can be placed inside each pack or pouch during sterilization of supplies or equipment

    in a validated pre-vacuum cycle. These emulating indicators can be used for routine monitoring of steam

    sterilization cycles.

    · Compatible with ISO 11140-1

    Ref# Description Packaging

    C-1055 Class 5 Laminated Intgrator, Triple Indicators, 134 C 3.5 min (Pack of 250)

    C-1055-SA Class 5 Laminated Intgrator, Triple Indicators, Self Adhesive 134 C 3.5 min (Pack of 250)

    70 pcs / Carton

    60 pcs / Carton

    70 pcs / Carton

    60 pcs / Carton

    60 pcs / Carton

    60 pcs / Carton

    70 pcs / Carton

    70 pcs / Carton

    70 pcs / Carton

    C-1601

    C-1601-SA

    C-1602

    C-1602-SA

    C-1035

    C-1035-SA

    C-1007

    C-1007-SA

    Class 6 Emulating Indicator, Single Big Dot, 134 C 3.5 min (Pack of 250)

    Class 6 Emulating Indicator, Single Big Dot, Self Adhesive 134 C 3.5 min (Pack of 250)

    Class 6 Emulating Indicator, Single Big Dot, 134 C 7 min (Pack of 250)

    Class 6 Emulating Indicator, Single Big Dot, Self Adhesive 134 C 7 min (Pack of 250)

    Class 6 Emulating Indicator, Triple Indicators, 134 C 3.5 min (Pack of 250)

    Class 6 Emulating Indicator, Triple Indicators, Self Adhesive 134 C 3.5 min (Pack of 250)

    Class 6 Emulating Indicator, Triple Indicators, 134 C 7 min (Pack of 250)

    Class 6 Emulating Indicator, Triple Indicators, Self Adhesive 134 C 7 min (Pack of 250)

    UNSAFE:

    SAFE:

    OPTIMUM:

    C-1055

    TYPE-6 (Class 6) Ind�cator

    C-1035

    C-1601

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/Pack Issue/UseClean/Decontaminate Sterilize StoreSterilizePrep/Pack Issue/Use

  • Formaldehyde Test

    · Different designs are available on request

    · Compatible with ISO 11140-1

    Formaldehyde Test is designed to be used at low temperature formaldehyde gas sterilizers. The test can be used

    in every pouch or pack and will provide assurance of sufficient formaldehyde gas penetration into the packs with

    uniform color change from claret red to green.

    · Water-based and non-toxic chemical indicator

    · It is easy to read and interpret

    Ref# Description Packaging

    80 pcs / Carton

    C-1083

    C-1088

    E.O Gas Test

    · Different designs are available on request

    · Compatible with ISO 11140-1

    E.O Gas Test is an ethylene oxide sterilization process indicator designed to indicate, through a visible color

    change, when the device has been exposed to an ethylene oxide sterilization process. The test designed to

    monitor all critical parameters of Ethylene Oxide sterilization (time, temperature, gas concentration, and

    humidity). The test can be used in every pouch or pack and will provide assurance of ethylene oxide gas

    penetration into the packs with uniform color change from blue to light green. This product is designed for use in

    ethylene oxide sterilizers.

    · It is easy to read and interpret

    · Water-based and non-toxic chemical indicator

    Ref# Description Packaging

    C-1081

    C-1086 80 pcs / Carton

    70 pcs / CartonEO Gas Indicator Strips Indicators (Pack of 250)

    EO Gas Indicator Strips Indicators 10 cm (Pack of 250)

    Formaldeyhde Indicator Strips Indicators (Pack of 250)

    Formaldeyhde Indicator Strips Indicators 10 cm (Pack of 250)

    70 pcs / Carton

    H2O2 Plasma Test

    H2O2 Plasma Test is designed to be used at low temperature hydrogen peroxide gas plasma sterilizers. The test

    can be used in every pouch or pack and will provide assurance of sufficient hydrogen peroxide gas penetration

    into the packs with uniform color change from purple to blue.

    · It is easy to read and interpret

    · Compatible with ISO 11140-1

    · Different designs are available on request

    · Water-based and non-toxic chemical indicator

    Ref# Description Packaging

    C-1080

    C-1087 80 pcs / Carton

    70 pcs / CartonH2O2 Plasma Indicator Strips Indicators (Pack of 250)

    H2O2 Plasma Indicator Strips Indicators 10 cm (Pack of 250)

    C-1081

    C-1080

    C-1083

    Container Filter

    Container Filter is based upon ISO 11140 standard and compliant to this standard. The used materials are

    mechanically strong to withstand the vacuum and steam pulse movements and are an effective barrier.

    · Water-based and non-toxic chemical indicator

    · It is easy to read and interpret

    · Compatible with ISO 11140-1

    Ref# Description Packaging

    40 pcs / CartonC-1077 Sterilization Container Filter Round with Steam Indicator (Pack of 100)

    C-1078 40 pcs / CartonSterilization Container Filter with Steam Indicator Special Production (Pack of 100)

    C-1077

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/Pack Issue/UseClean/Decontaminate Sterilize StoreSterilizePrep/Pack Issue/Use

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/Pack Issue/Use

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/Pack Issue/Use

  • Plastic Security Seals

    · Different sizes are available

    Containers are sealed with plastic security seals for single use, these can be open only by cracking. The plastic

    security seals will be introduced prior to sterilization in the cross hole of the lock and closed. Plastic security seals

    are safeguarding the container against unauthorized opening and it prevents opening by unauthorized staff. The

    easiest method of quickly identifying or marking instruments, trays, trolleys or other equipment. Different seal

    sizes are available to use with different container types.

    · Water-based and non-toxic chemical indicator

    · It is easy to read and interpret

    · Compatible with ISO 11140-1

    · With or without Indicator and red or blue color options are available

    Ref# Description Packaging

    C-1070

    C-1071

    C-1072

    C-1073

    C-1201

    C-1202

    C-1203

    C-1204

    Plastic Security Seal Standard Model for Sterilization Containers, BLUE (Pack of 100)

    Plastic Security Seal Standard Model for Sterilization Containers, RED (Pack of 100)

    Plastic Security Seal Standard with Steam Indicator Model for Sterilization Containers, BLUE (Pack of 100)

    Plastic Security Seal Standard with Steam Indicator Model for Sterilization Containers, RED (Pack of 100)

    Plastic Security Seal LONG Model for Sterilization Containers, BLUE (Pack of 100)

    Plastic Security Seal LONG Model for Sterilization Containers, RED (Pack of 100)

    Plastic Security Seal LONG Model with Steam Indicator for Sterilization Containers, BLUE (Pack of 100)

    Plastic Security Seal LONG Model with Steam Indicator for Sterilization Containers, RED (Pack of 100)

    50 pcs / Carton

    50 pcs / Carton

    50 pcs / Carton

    50 pcs / Carton

    50 pcs / Carton

    50 pcs / Carton

    50 pcs / Carton

    50 pcs / Carton

    C-1070 C-1071 C-1072 C-1073

    C-1201 C-1202 C-1203 C-1204

    Self-Adhesive Seals

    · Non-Self-Adhesive versions are available on request

    Container seal labels have been especially designed to safeguard the container from being opened by

    unauthorized personnel. The function of the container label is to safeguard and mark containers. It can also be

    used for documentation purposes.

    · Water-based and non-toxic chemical indicator

    · It is easy to read and interpret

    · Compatible with ISO 11140-1

    · Different designs are available

    · Self-Adhesive versions can be used as a permanent record for traceability purposes

    Ref# Description Packaging

    C-1074 50 pcs / CartonSelf Adhesive Sterilization Container Seal with Steam Indicator (Pack of 100)

    Container Labels

    · Non-Self-Adhesive versions are available on request

    Container labels are designed to be used in the pocket of the containers. Container Labels are offered as a self-

    adhesive and as a non-self-adhesive label. Self-adhesive labels are a very suitable alternative to the often-used

    steam tapes. Indicators by which one can differentiate sterilized and non-sterilized containers.

    · Water-based and non-toxic chemical indicator.

    · It is easy to read and interpret

    · Compatible with ISO 11140-1

    · Self-Adhesive versions can be used as a permanent record for traceability purposes

    · Different designs are available

    Ref# Description Packaging

    C-1076 -Sterilization Container Label with Steam Indicator Small (Pack of 100)

    50 pcs / CartonC-1075 Sterilization Container Label with Steam Indicator (Pack of 100)

    C-1074

    C-1075

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/Pack Issue/UseClean/Decontaminate Sterilize StoreSterilizePrep/Pack Issue/Use

    Clean/Decontaminate Sterilize StoreSterilize

    Prep/Pack Issue/Use

    2023-07

    2019-07

    :C-1074

    :190716

    2023-07

    2019-07

    :C-1074

    :190716

    2023-07

    2019-07

    :C-1074

    :190716

  • Self-Adhesive DocumentationLabel and Labeler

    · Compatible with ISO 11140-1

    · Water-based and non-toxic chemical indicator

    · 2- and 3-line labels options are available on request

    · It is easy to read and interpret

    · Double side self-adhesive labels designed for track and control sterilization processes

    Self-adhesive Documentation Labels are double side self-adhesive labels with chemical indicators designed for

    track and control sterilization processes. On the labels there is an ink printed chemical indicator which is defined

    as Type 1 according to EN ISO 11140-1 standards. Compatible with all manual traceability systems, it is very

    suitable to hospital, clinic and for both large and table top sterilizers. After sterilization the labels peeled off and

    reapplied to either patient or department records as evidence of an effective process.

    Labeler is a 3-title handheld labeler. Using the highest technology and best materials. It can be easily replaced

    due to major mechanical or material deficiencies. Label and ink roller can be changed easily.

    Labeler has 3 line with each has 10 digits and Compatible with 26x28 mm labels.

    Ref# Description Packaging

    -

    12 pcs / Box

    3 Lines Handlabler

    STEAM 3 line Documentation Label 700 pcs of Roll (24 mm x 26 mm)

    STEAM 3 line Documentation Label 750 pcs of Roll (26 mm x 28 mm)

    STEAM 2 line Documentation Label 750 pcs of Roll (17 mm x 34 mm)

    -

    -

    C-1003

    C-1002

    C-1004

    C-1011

    C-1012

    C-1014

    C-1013

    STEAM Roll Documentation Label (35 mm x 57 mm)

    STEAM Roll Documentation Label (35 mm x 67 mm)

    STEAM Roll Documentation Label (48 mm x 70 mm)

    -

    -

    -

    Individual Bowie&Dick Test

    Individual Bowie-Dick Test Sheets are designed for use in the towel-pack version of Bowie & Dick test. The high

    sensitivity ink of the product and easy interpretation of color changes guarantee the earliest possible warning of

    impending problems in pre-vacuum sterilizers. A Bowie-Dick Test Sheet should be placed within a stack of

    surgical towels that are assembled according to AAMI guidelines.

    · Individual Bowie-Dick tests make testing steam penetration and air removal, as well as detecting air leaks,

    more convenient and cost effective

    · Water-based and non-toxic chemical indicator

    · Indicator pattern is easy to read and interpret

    · The indicator sheet contains fields to be filled out and it can be kept as a permanent record for traceability

    purposes

    · Different designs are available on request

    · Compatible with ISO 11140-4 (Class 2 + 4)

    Ref# Description Packaging

    BD-10 Bowie & Dic Test Big Size Test Sheet (pack of 100) -

    C-1003

    C-1012 C-1014C-1013

    C-1002

    C-1004

    C-1011

    BD-10

    Clean/Decontaminate SterilizeSterilize

    Prep/PackClean/Decontaminate Store

    Prep/Pack Issue/UseSterilizeSterilize Store Issue/Use

  • Ultrasonic Washer Test

    Ultrasonic Washer Tests consist of a clear vial filled with reactive green-colored solution and glass beads. The

    device monitors the cavitation capacity of the ultrasonic washer. When functioning correctly, vibration of glass

    pearls will trigger a color change to a yellow color. Ultrasonic Washer Tests do not require a special holder to be

    used. The washer test should be checked daily and weekly than results should be recorded.

    · It is easy to read and interpret

    · Compatible with ISO 15883-5

    When do I use Ultrasonic Washer Test?

    Ultrasonic Washer Tests should be used in each ultrasonic cycle. The Ultrasonic Washing machine should also be

    checked at least once a week with recorded results. This will detect any deterioration in the performance of the

    cleaner and assist in preventing ineffective washing.

    · It is easy to read and interpret

    Seal Check is used to control the sealing machine whether if it meets the sealing standards or not. Seal Check;

    visibly show the sealing machine results and quality so that the sealing problems can be found quickly and can be

    used to ensure the sealing parameters, requirements, and the quality.

    Seal Test

    Ref# Description Packaging

    C-1001 50 pcs / CartonSEAL TEST For Rotary Sealers (Pack of 100)

    Ref# Description Packaging

    U-1001 -Ultracheck Ultrasonic Washer Dosimeter (Pack of 30)

    Washer Disinfector Efficiency andUltrasonic Efficiency Control Test

    Designed for monitoring washer and ultrasonic washer device efficiency. Both can be used Stainless Steel Frame

    as their holder.

    · Both can be used with the holder

    · It is easy to read and interpret

    · Ready-to-use (single use product)

    · Test provides efficient and reliable results

    · Compatible with ISO 15883-5

    · Transparent cover to enable visual check

    Ref# Description Packaging

    C-1061 70 pcs / CartonWasher Disinfector Efficiency Control Test

    C-1065 60 pcs / CartonUltrasonic Efficiency Control Test

    Washer Tag with Washer DisinfectorCleaning Efficiency Test Soil

    · Patented design

    Washer Tags are designed to be used as a tag to identify if the tray is washed or not.

    · Ready-to-use (single use product)

    · It is easy to read and interpret

    · Test provides efficient and reliable results

    Ref# Description Packaging

    C-1064 70 pcs / Carton

    C-1063 -Stainless Steel Frame for C-1061 & C-1065

    Washer Tag with washer disinfector cleaning efficiency test soil (Pack of 100)

    U-1001

    C-1001

    C-1063

    C-1065 C-1061

    C-1064

    Clean/Decontaminate

    Prep/Pack Store Issue/UseSterilize

    Clean/Decontaminate Store Issue/UseSterilize

    Prep/Pack

    Clean/Decontaminate Store Issue/UseSterilize

    Prep/Pack

    Clean/Decontaminate Store Issue/UseSterilize

    Prep/Pack

  • New Test Soil and Stainless Steel PCD

    New Test Soil is used for daily control and validation of the washer-disinfectors. It is also made from steel and has

    a coating that simulates human blood. When it is used with Stainless Steel PCD which is like a steel box with holes

    and a spring, they simulate a joint of medical equipment.

    · Ready-to-use (single use product)

    · Test provides efficient and reliable results

    · Test made from steel

    · The coating on the test simulates human blood

    · It is easy to read and interpret

    Ref# Description Packaging

    C-1060

    C-1062

    Washer Disinfector Efficiency Test Stainless Steel

    Stainless Steel PCD for C-1060

    70 pcs / Carton

    60 pcs / Carton

    Cannulacheck

    · It is easy to read and interpret

    After washing cycle, test must be visually clean. If not; washing cycle must be repeated.

    Cannulacheck can be considered as a kind of simulation which performs like dried blood on a long stainless steel

    placed inside hollow closed metal as same as hollow instruments of minimal invasive surgery. With its closed

    stainless-steel system, cleaning performance of washers can be tested whether their performance enough to

    reach inside of hollow instruments.

    · Ready-to-use

    · Test single use product and the tube is reusable

    · Test provides efficient and reliable results

    Ref# Description Packaging

    T-1002

    T-1003

    Washer Tag with washer disinfector cleaning efficiency test soil

    Cannulacheck PCD

    -

    -

    Washer Disinfector CleaningEfficiency Test

    · Test made from steel and it has a plastic container that enables the user to hang the test on the washer-

    disinfectors

    · Transparent cover to enable visual check

    · The coating on the test simulates human blood

    · Ready-to-use (single use product)

    · It is easy to read and interpret

    · Test provides efficient and reliable results

    Washer Disinfector Cleaning Efficiency Test enables you to verify the cleaning efficacy of washer-disinfectors

    during routine operation check. The routine use of this test will help ensure that your washer is performing at a

    consistent level, enhancing the routine visual inspection of instruments. If unfavorable results do occur, users

    must check quality/ quantity of detergent, cleaning time, temperature as well as general condition of the washer.

    Ref# Description Packaging

    T-1001 -Washer Disinfector Efficiency Test with PCD Frame Design

    Surgical Instrument Soil Test Solution

    Inefficient cleaning can put disinfection and sterilization procedures at risk. A poorly functioning washer-

    disinfector can leave behind microscopic debris that can severely compromise both the disinfection and

    sterilization process. One of the best and easiest ways to check whether instruments are being cleaned

    effectively is to present the cleaning equipment with a physical challenge such as the cleaning efficacy tests.

    Surgical Instrument Soil Test Solution is designed to simulate the soiling that naturally occurs during theatre use

    and performs in an equivalent manner to the human blood. The red color of the Surgical Instrument Soil Test

    Solution allows easy identification of areas that have not been properly cleaned, providing a visual analysis of

    equipment efficiency.

    · Easy to use and interpret

    · Non-toxic chemical indicator

    · Compatible with ISO 15883-5

    Ref# Description Packaging

    S-1001 -Surgical Instrument Soil Test Solution (Pack of 32)

    C-1062

    C-1060

    T-1002

    T-1003S-1001

    T-1001

    Clean/Decontaminate

    Prep/Pack Store Issue/UseSterilize

    Clean/Decontaminate

    Prep/Pack Store Issue/UseSterilize

    Clean/Decontaminate

    Prep/Pack Store Issue/UseSterilize

    Clean/Decontaminate

    Prep/Pack Store Issue/UseSterilize

  • SMS Wrap

    SMMS wrapping paper consists of three nonwoven polypropylene fabric layers and can be used either as inner or

    outer wrapping of medical devices and trays. The spunbond layers (S) provide good filtration properties, tensile

    strength and are fluid repellent while the meltblown layers (M) ensure strong bacterial barrier properties with

    very small porous size.

    SMMS wraps as single or double wrapped are suitable for steam, ethylene oxide and hydrogen peroxide plasma

    sterilization methods. The memory-free feature before and after sterilization ensures good aseptic presentation.

    Ref# Description Packaging

    SMS-5050

    SMS-6060

    SMS-7575

    SMS-9090

    SMS-100100

    SMS-100120

    SMS-120120

    SMS Sterilization Wrap (50 cm x 50 cm)

    SMS Sterilization Wrap (60 cm x 60 cm)

    SMS Sterilization Wrap (75 cm x 75 cm)

    SMS Sterilization Wrap (90 cm x 90 cm)

    SMS Sterilization Wrap (100 cm x 100 cm)

    SMS Sterilization Wrap (100 cm x 120 cm)

    SMS Sterilization Wrap (1200 cm x 1200 cm)

    250 pcs / Carton

    250 pcs / Carton

    250 pcs / Carton

    200 pcs / Carton

    125 pcs / Carton

    125 pcs / Carton

    125 pcs / Carton

    Certificates

    SMS-5050

    Clean/Decontaminate Sterilize

    Prep/Pack Store Issue/Use