product data - exrg

12
Comfort cooling VPL 28 BY NILAN PRODUCT DATA Domestic Ventilation < 1000 m 3 /h Comfort heating Active heat recovery Ventilation & active heat recovery

Upload: others

Post on 02-Oct-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRODUCT DATA - EXRG

Comfortcooling

VPL 28 BY NILAN

PRODUCT DATA

Domestic Ventilation < 1000 m3/h

Comfortheating

Activeheat recovery

Ventilation & active heat recovery

Page 2: PRODUCT DATA - EXRG

2

VPL 28 Product description

The cooling circuit is driven by a reliable reciprocating compressor.

The efficient fans run on low-energy EC motors.

VPL 28 is supplied with a closed cooling circuit.

The unit can therefore be installed with-out the help of a cooling technician.

Intelligent humidity sensors provide an option for controlling the ventilation as required, based on the average air humid-ity in the home.

A CO2 sensor can be purchased as anaccessory.

The unit comes with a clear anduser-friendly operating panel.

The modern CTS 602 control panel runs Modbus communication.

The alternative to an FU 15 heat pipe unit is the installation of an external water heater or electrical heating element (accessory).

Time-controlled alarm for filter exchange.

G4 duct filter can be installed. By connecting of FU28 heat pipe unit a M5 and F7 filter can be installed.

Reversible cooling circuit, which means that the heat pump can heat and cool the supply air.

The bypass valve regulate the intakes air temperature, maintaining it at a constant level.

The option of the FU 28 heat pipe unit with heat pipe will significantly increase the unit efficiency. This can maintain a high intake air temperature without using a heating coil.

The powder-coated condensate drain prevents the formation of “acid water” and allows the condensate to be drained away.

VPL 28 is an energy-efficient ventilation unit for heat recovery and cooling of homes and small commercial buildings with a ventilation requirement of up to 1000 m3/h.

Heat recovery is via a heat pump that can utilise the recovered energy better than with e.g. a counterflow heat exchanger.

The heat pump has a reversible cooling circuit, which means that the unit can both heat and cool the air.

VPL 28 is supplied fully tested and ready for use. Fitting and commissioning must be carried out by an authorised electrician or plumber.

Page 3: PRODUCT DATA - EXRG

3

VPL 28 BY NILAN

Dimensions (W x D x H) 700 x 570 x 765 mm

Weight 65 kg

Plate type casing Aluzinc steel plate, white powder coating RAL9016

Compressor type Piston compressor

Refrigerant R407C

Fan type EC, constant volume

Filter class G4 duct filter

Duct connections Ø250 mm

Condensate drain PVC, Ø 20×1,5 mm

Supply voltage 230 V (±10 %), 50/60 HZ

Max. input/power 2139 W / 9.3 A

Tightness class IP31

Standby power 3 W

Ambient temperature -20 / +40 °C

Technical specifications

Overfladebehandling:

D

E

F

C

1 2 3 4

B

A

321 5

C

D

4 6 7 8

A

B

g

mål i millimeter og alle vinkler i grader

Fax: 76 75 25 25

: bukkes 90° ned: bukkes 90° op

Med mindre andet er angivet gælder:Mål markeret med O er kontrolmål

VPL 25 - EC

ha 14. juli 2006 07:02:37

ha

Revideret:

Titel:

Tegning nr.

VPL25_28

Tegn. af:

Kontr. af:

Godk. af:

Antal pr. anlæg:

Initialer Dato Materiale:

Målestok:1:10 Sheet 1 af 1Format: A3

Vægt:

13. januar 2005 09:45:27

Fil: V:\SW_multiuser\Dummy_anlæg\VPL25_28\VPL25_28

Revision

Mål markeret med () er konturmålFor pladedele gælder:

8722 HedenstedNilanvej 2Nilan A/S

www.nilan.dk

Tlf: 76 75 25 00

Hvis andet ikke er specificeret er alle

Info:

This drawing is the property of Nilan A/S and may not without writtenpermission be copied or turned over to other persons or companies

Denne tegning er Nilan A/S ejendom, og må ikke kopieres ellervideregives til tredjemand uden skriftlig tilladelse

700

740

65,2

765

VenstreHøjre29

3

405

472

570

161

285

294,

1

170,

9

470,

9

Overfladebehandling:

D

E

F

C

1 2 3 4

B

A

321 5

C

D

4 6 7 8

A

B

g

mål i millimeter og alle vinkler i grader

Fax: 76 75 25 25

: bukkes 90° ned: bukkes 90° op

Med mindre andet er angivet gælder:Mål markeret med O er kontrolmål

VPL 25 - EC

ha 14. juli 2006 07:02:37

ha

Revideret:

Titel:

Tegning nr.

VPL25_28

Tegn. af:

Kontr. af:

Godk. af:

Antal pr. anlæg:

Initialer Dato Materiale:

Målestok:1:10 Sheet 1 af 1Format: A3

Vægt:

13. januar 2005 09:45:27

Fil: V:\SW_multiuser\Dummy_anlæg\VPL25_28\VPL25_28

Revision

Mål markeret med () er konturmålFor pladedele gælder:

8722 HedenstedNilanvej 2Nilan A/S

www.nilan.dk

Tlf: 76 75 25 00

Hvis andet ikke er specificeret er alle

Info:

This drawing is the property of Nilan A/S and may not without writtenpermission be copied or turned over to other persons or companies

Denne tegning er Nilan A/S ejendom, og må ikke kopieres ellervideregives til tredjemand uden skriftlig tilladelse

700

740

65,2

765

VenstreHøjre

293

405

472

570

161

285

294,

1

170,

9

470,

9

Overfladebehandling:

D

E

F

C

1 2 3 4

B

A

321 5

C

D

4 6 7 8

A

B

g

mål i millimeter og alle vinkler i grader

Fax: 76 75 25 25

: bukkes 90° ned: bukkes 90° op

Med mindre andet er angivet gælder:Mål markeret med O er kontrolmål

VPL 25 - EC

ha 14. juli 2006 07:02:37

ha

Revideret:

Titel:

Tegning nr.

VPL25_28

Tegn. af:

Kontr. af:

Godk. af:

Antal pr. anlæg:

Initialer Dato Materiale:

Målestok:1:10 Sheet 1 af 1Format: A3

Vægt:

13. januar 2005 09:45:27

Fil: V:\SW_multiuser\Dummy_anlæg\VPL25_28\VPL25_28

Revision

Mål markeret med () er konturmålFor pladedele gælder:

8722 HedenstedNilanvej 2Nilan A/S

www.nilan.dk

Tlf: 76 75 25 00

Hvis andet ikke er specificeret er alle

Info:

This drawing is the property of Nilan A/S and may not without writtenpermission be copied or turned over to other persons or companies

Denne tegning er Nilan A/S ejendom, og må ikke kopieres ellervideregives til tredjemand uden skriftlig tilladelse

700

74065

,2

765

VenstreHøjre

293

405

472

570

161

285

294,

1

170,

9

470,

9

Dimensional drawing

Connections

1: Fresh air 2: Supply air 3: Extract air 4: Discharge air 5: Condensate drain

All dimensions are in mm.

12

34

5

Page 4: PRODUCT DATA - EXRG

4

Product descriptionAn option is a FU 28 heat pipe unit with filter, which is connected to the VPL 28 unit.

The heat pipe slightly raises the temperature of the outdoor air, thereby increasing the heat pump’s efficiency in the VPL 28 aggregate significantly during the winter.

With an integrated FU 28 heat pipe unit, in most cases there is no need for a heating coil with mixing circuit.

For FU 28 a bag filter M5 and F7 can be ordered.

FU 28

Scan the QR code

Scan the QR code with your smartphone or tablet and view a brief film on:

• How the VPL aggregates function

• How efficient heat recovery is

• How the cooling functions

D

E

F

A

D

A

gha

ha

Initialer Dato

Nilan A/SNilanvej 28722 Hedensted

Tlf: 76 75 25 00Fax: 76 75 25 25

www.nilan.dk

D

E

F

A

D

A

gha

ha

Initialer Dato

Nilan A/SNilanvej 28722 Hedensted

Tlf: 76 75 25 00Fax: 76 75 25 25

www.nilan.dk

D

E

F

A

D

A

gha

ha

Initialer Dato

Nilan A/SNilanvej 28722 Hedensted

Tlf: 76 75 25 00Fax: 76 75 25 25

www.nilan.dk

Dimensional drawing

Connections

1: Fresh air 2: Supply air 3: Extract air 4: Discharge air

All dimensions are in mm.

1

34

2

Page 5: PRODUCT DATA - EXRG

5

VPL 28 BY NILAN

Connections

1: Fresh air 2: Supply air 3: Extract air 4: Discharge air

External communication

The CTS 602 control unit communicates by default with Modbus RTU RS485 communication. A CTS system using this form of communication can easily be connected to the unit.

Nilan units have an open Modbus communication, i.e. not only can the unit be monitored, but its operation can also be set in the same way as it can via the operating panel.

The protocol is set up by default for a Modbus RTU 30 address, but can be set to a value between 1 and 247.

A Modbus converter allows you to connect one or more units to a computer to monitor and control the unit.

KonverterCTS / Computer

Modbus

COMMUNICATION

OPERATION

5

6

7

8

9

4

3

2

1

10

11

40 50 60 70 80 90 100302010

Imm

edia

tely

cha

nge

in %

of R

H

Average RH (the last 24 hours)

Reducedventilation

Forced ventilation

Normal ventilation

Intelligent humidity controlNilan’s humidity control automatically adapts to the needs of the family or the building.

The intelligent CTS 602 control unit does not need to have a set level input for air humidity (RH) to control the air exchange. By using the integrated humidity sensor, the control unit calcu-lates the average level itself for the last 24 hours. The average level provides a basis for deciding whether to change the air exchange if the air humidity fluctuates.

This ensures that the unit always runs at its most efficient, based on the actual air humidity level and not on a theoretical one.

This helps save energy because it automatically adapts to the requirements in the home. Whether a large family or a single person is living in the building has a considerable influence on how much humidity is produced.

The unit also adjusts automatically to summer and winter level.

If the air humidity changes by more than 5-10% in relation to the

average level, the unit responds with a higher rate of air exchange

accordingly.

At an air humidity below 30% is reduced ventilation stp activated

(adjustable between 15 and 45%)

Page 6: PRODUCT DATA - EXRG

6

0 5 10 15 20-5-10-152

3

4

5

6

7

8

1100 m3/h

800 m3/h

500 m3/h

Heat effect (supply air)Heat effect Qc [W] as a function of qv [m3/h]and fresh air temperature [°C].

According to EN 14511, extract air = 21 °C

PLANNING DATACapacity

Max Pa capacity of standard unit, Pt,ext as a function of qv, with regard to SEL-values.

SEL-values according to EN13414-7 for a standard unit with G4-filters an no heating element.

SFP values comprise the unit total power comsumption incl. control.

Conversion factor:

0-5-10-15 5 10 15 200

1000

2000

3000

4000

5000

6000

7000

8000

9000

1100 m3/h800 m3/h

500 m3/h

Compressor effect

Outdoor temperature [°C]

Qc [W

]

COP (heating)Heat effect factor COP [-] supply air as function of outdoor temperature [°C] and volume flow qv [m3/h].

According to EN14511, extract air = 21°C.

Outdoor temperature [°C]

COP

[-]

With heat pipe

With heat pipe

Without heat pipe

Without heat pipe

Med heat pipeUden heat pipe

300 400 500 600 700 800 900 1000 1100 1200 1300 1400 15000

100

200

300

400

500

Max Pa2100 J/m3

1800 J/m3

1500 J/m3

qv [m3/h]

qv [l/s]100 125 150 175 200 225 250 275 300 325 350 375 400

pt,ext

(Pa)

Pressure loss heating elementJ/m3

= W/m3/h3600

Page 7: PRODUCT DATA - EXRG

7

VPL 28 BY NILAN

-150,0

5,0

10,0

15,0

20,0

25,0

30,0

35,0

40,0

45,0

0-5-10 5 10 15 20

500 m3/h

800 m3/h

1100 m3/h

Supply air temperature (heating)

Supply air temperature [°C] as a function offresh air temperature [°C] and volume flow qv [m3/h] balanced flow.

Extract air temperature = 21 [°C], 45 RH [%]

Outdoor air [°C]Su

pply

air

tem

pera

ture

[°C]

Supply air temperature (cooling) Supply air temperature [°C] as a function of fresh air temperature [°C] and volume flow qv [m3/h]balanced flow. Extract air temperature = 24°C

18 23 28 33 3814

15

16

17

18

19

20

21

22

23

241100 m3/h

800 m3/h

Outdoor air [°C]

Supp

ly a

ir te

mpe

ratu

re [°

C]

Med heat pipeUden heat pipe

With heat pipeWithout heat pipe

Sound dataSound data for qV = 1000 m3/h and Pt, ext = 200 Pa according to EN 9614-2 for surfaces and EN 5136 for ducts.

Sound output level LWA drops with falling air volume and falling back pressure.Sound output level LpA at a given distance will depend on acoustic conditions in the place of installation.

Octave band Hz

Surface dB(A)

Supply air dB(A)

Extract air dB(A)

Fresh air dB(A)

Discharge air dB(A)

125 60.3 70.6 69.0 68.3 70.3

250 50.7 72.4 70.4 69.7 72.3

500 32.6 69.6 59.4 58.6 69.4

1.000 31.3 72.5 59.9 58.3 72.3

2.000 34.1 71.7 55.9 53.1 71.6

4.000 33.5 69.2 47.3 44.5 69.1

Total ±2 dB(A) 65.0 82.0 76.0 75.0 81.0

Sound output level (LWA)

Page 8: PRODUCT DATA - EXRG

8

CTS 602 Control The VPL 28 is controlled by using the CTS 602 operating panel, featuring a wide range of functions, e.g., menu-con-trolled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cool-ing), post-heating element control, error messages etc.

The CTS 602 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system.

The operating panel must be placed in a dry, frost-free loction, at least 1.5 m above floor level and at least 0.5 m from any corner. Avoid placing the panel on an external wall or in areas in direct sunlight.

Operating instructions for the CTS 602 can be found in a sepa-rate user manual supplied with the unit.

T5

T6

2

4

6

5

TC

TC

T11

3

T2

T5

T6

2

4

6

5

TC

TC

T11

3

T2T7TC

T9

TILSLUTNINGER:

1: Udeluft2: Tilluft3: Fraluft4: Afkastluft5: Kondensafløb6: El-tilslutning

AUTOMATION:T1: UdefølerT2/T7: TilluftfølerT9/TC: Eftervarmeflade frostsikringT5: KondensatorfølerT6: FordamperfølerT10: Rumføler

T5

T6

2

4

6

5

TC

TC

T11

3

T2

T5

T6

2

4

6

5

TC

TC

T11

3

T2T7TC

T9

TILSLUTNINGER:

1: Udeluft2: Tilluft3: Fraluft4: Afkastluft5: Kondensafløb6: El-tilslutning

AUTOMATION:T1: UdefølerT2/T7: TilluftfølerT9/TC: Eftervarmeflade frostsikringT5: KondensatorfølerT6: FordamperfølerT10: Rumføler

Heating Cooling

AUTOMATION

Connections

1: Fresh air 2: Supply air 3: Extract air 4: Discharge air 5: Condensate drain 6: Electric and water heating

Automatik

T1: Outdoor air sensor T2/T7: Supply air sensor T9: Heating element frost protection T5: Capacitor sensor T6: Evaporator sensor T10: Room sensor

Functional diagrams

Page 9: PRODUCT DATA - EXRG

9

VPL 28 BY NILAN

Functional overview + Standard

- Accessories

3 levels The control function is divided into 3 levels: User/Service/Factory with various options at each level +

Weekly plan The unit has 3 weekly programmes (with a factory setting of “off”)• Programme 1: for working families• Programme 2: for stay-at-home families• Programme 3: for businessesThere is also an option for you to set your own weekly programme.

+

User option 1 This allows you to overwrite the operating mode in the main menu via an external potential-free contact or PIR sensor.

+

Alarms Alarm log featuring the last 16 alarms. +

Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days. +

Bypass Bypassing the outdoor air reduces heat recovery, enabling the desired supply air temperature to be maintained spring, summer and autumn.

+

Air quality Allows you to choose whether to switch humidity sensors and/or CO2 sensors on and off. -

Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity. +

CO2 control Allows you to set a higher or lower ventilation step in the case of a high/low CO2 level. -

Air exchange Allows you to select a low ventilation step in the case of low outside temperatures and air humidity. +

Frostprotection In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting.

+

Temperature control Allows you to select the temperature sensor which will control the unit.• T15 ROOM (panel sensor)• T10 EXT (fitted in a representative extraction valve)• T3 EXHAUST (extract air)

+

Room low Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from 1 to 20 degrees and is controlled by:• T15 ROOM (panel sensor)• T10 EXT (fitted in a representative extraction valve)• T3 EXHAUST (extract air)

+

Room control Allows you to set the regulator to control the room temperature. +

Air volume Allows you to set four ventilation steps. Supply air and extract air are set individually.Step 1 < 25% - Step 2 < 45% - Step 3 < 70% - Step 4 < 100%

+

Fire alarm This allows you to connect fire-detecting thermostats, smoke detectors and other fire alarm contacts. In case of an alarm, smoke dampers are closed and the unit stops.

+

Joint alarm Outlet for joint alarm +

Constant pressure control Allows control from both the extract air and supply air side. -

Cooling The heat pump has a reversible cooling circuit, which means that the cooling circuit can be reversed, with the unit cooling instead of heating the supply air.

+

Night cooling It is possible the set the control to run night cooling. +

Intake air control Allows you to set the regulator to control the intake air temperature/supply air(only available if the control unit has been configured for a supply-heating element).

+

External heating element • Temperature sensor T7 is an supply air sensor• Integrated frost protection for external water heating element• Motorised valve and circulation pump control unit

-

External electric heating element

• Temperature sensor T7 is an supply air sensor• Overheating protection

-

Delayed start-up There is a possibility for a delayed start-up by the fans, when a closing damper is installed. +

Expansion PCB Allows you to make additional connections, e.g.• User option 2 overrides User option 1 (e.g. connecting an EM box)• Up to 500 W direct• Can give the signal for external heating if the defrost function is used• Switching the central heating system on/off

-

Reset Allows you to restore the factory settings. +

Manual test Allows you to test the unit’s functions manually. +

Language Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/French). +

Page 10: PRODUCT DATA - EXRG

10

CO2-sensor With a CO2-sensor installed, the ventilation speed can be pre-programmed with CTS 602 to run at a higher ventilation steps when CO2 reaches high level in the extract air. CO2-level is programmable.

Water heating element incl. regulation The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the duct and must be connected to the primary heating supply. Supplied with two-way adjust-ment valve, temperature sensor and frost thermostat.

Electrical heating surface incl. regulation When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors.

EM-box An EM-box allows heat recovery from the air from the range hood and thereby helps to heat the supply air. The EM-box is equipped with a special filter which efficiently cleans the range hood air of fat particles and thereby protects the system.

Expansion PCB The expansion PCB provides additional functions for the CTS 602 control unit, e.g., controlling the EM box (see list of functions on page 9).

Installation kit The installation kit comprises of four vibration absorbers and a water trap for the condensation outlet. The water trap can be ordered separately.

Heating cable To protect the condensation outlet against frost, a 3 metre-long self-regulating

heating cable can be ordered.

ACCESSORIES

Page 11: PRODUCT DATA - EXRG

11

VPL 28 BY NILAN

VPL 28

VPL 15 + FU 15

Min. 10,5 cm

Min. 60 cm

Min. 15 cm

Min. 15 cm

Min. 10,5 cm

Min. 60 cm

Heizregister

Min. 32 cm

El-varmeflade

VPL 28 + FU 28

Electric heating elements (accessories) are fitted in the duct. The fitter should ensure that there is a safe distance of at least 15 cm between the electric heating element and any inflammable material. The heating element must be insulated using fire-resistant insulation material.

The electric heating element must be connected by an authorised electrician.

Installation of electric heating element

Transport and storageVPL 28 comes in factory packaging that protects it during transport and storage. VPL 28 must be stored in a dry place in its original packaging until installation.

The packaging should only be removed immediately prior to installation.

Installation conditionsWhen installing, plan ahead for service and maintenance. We recommend minimum clearance in front of and behind the unit of 60 cm.

Ensure the unit is level, with regard to the condensation drain. The condensation drain requires clearance of min. 10.5 cm under the drain spout.

Use a flexible connection between the unit’s nozzle and duct system.

The unit is quiet and low vibration, but the fact that vibrati-ons can still be transmitted to the building fabric should be taken into account. We recommend a minimum distance of 30 mm to the building fabric and other fixtures. We recommend erecting the unit on vibration dampers to separate it from the surface it stands on.

DELIVERY AND HANDLING

Electricheating element

Page 12: PRODUCT DATA - EXRG

Ver.

2.01

- 20

14.1

0WWW.NILAN.DK

Nila

n A

/S p

åtag

er s

ig in

tet a

nsva

r fo

r ev

entu

elle

fejl

og m

angl

er i

tryk

t inf

orm

atio

nsm

ater

iale

– e

ller

for

tab

elle

r sk

ader

som

følg

e af

det

pub

licer

ede

mat

eria

le, h

vad

ente

n de

tte

skyl

des

fejl

elle

r uh

ensi

gtsm

æss

ighe

der

i mat

eria

let

elle

r an

dre

årsa

ger.

Nila

n A

/S fo

rbeh

olde

r si

g re

t til

uden

foru

dgåe

nde

vars

el a

t for

etag

e æ

ndri

nger

af p

rodu

kter

og

info

rmat

ions

mat

eria

ler.

Alle

var

emæ

rker

tilh

ører

Nila

n A

/S, o

g al

le r

etti

ghed

er fo

rbeh

olde

s.

INFORMATION FROM A TO ZNilan develops and manufactures premium-quality, energy-saving ventilation and heat pump solutionsthat provide a healthy indoor climate and low-level energy consumption with the greatest consideration forthe environment. In order to facilitate each step in the construction process – from choosing the solutionthrough to planning, installation and maintenance – we have created a series of information material whichis available for download at www.nilan.dk.

BrochureGeneral information about the solution and its benefits.

Product dataTechnical information to ensure correct choice of solution.

Installation instructionsDetailed guide for instal-lation and initial adjust-ment of the solution.

User manualDetailed guide for regulation of the solution to ensure optimum day-to-day operation.

DrawingsTender documents and 3D drawings are available to down-load for planning purposes.

Visit us at www.nilan.dk to find outmore about our company and solutions,download further information and findyour nearest dealer.

Nilan A/SNilanvej 28722 HedenstedDEnmarkTel. +45 76 75 25 00Fax +45 76 75 25 [email protected]