product guide · 2218, class 4 impact resistance codes and compliances can/csa-a123.5-m90 florida...

6
www.AtlasRoofing.com SHINGLES, UNDERLAYMENTS & ACCESSORIES PRODUCT GUIDE Shingles Underlayments Hip & Ridge Starter Strips

Upload: others

Post on 17-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRODUCT GUIDE · 2218, Class 4 Impact Resistance Codes and Compliances CAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792 Miami-Dade County-Dade Product Control Approved

www.AtlasRoofing.com

SHINGLES, UNDERLAYMENTS & ACCESSORIES

PRODUCT GUIDE

Shingles

Underlayments

Hip & Ridge

Starter Strips

Page 2: PRODUCT GUIDE · 2218, Class 4 Impact Resistance Codes and Compliances CAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792 Miami-Dade County-Dade Product Control Approved

YOUR ROOF SHOULD BEAN ATLAS SYSTEM

Designer Shingles StormMaster® Slate StormMaster® Shake Pinnacle® featuring Scotchgard™ Protector Pinnacle® HP featuring Scotchgard™ Protector Pinnacle® Pinnacle® HP GlassMaster®

Hip & Ridge Pro-Cut® Hip & Ridge

Underlayment Gorilla Guard® Summit® Synthetic WeatherMaster® #30 Saturated Felt

Starter Strips Pro-Cut® Starter Strip

Roofing SystemRoofing System Atlas Signature Select® is a cohesive roofing system, who's components are specifically chosen to work together. That's why we'll

UPGRADE your roof's Premium Protection Period when you install Atlas qualifying roof components.

Page 3: PRODUCT GUIDE · 2218, Class 4 Impact Resistance Codes and Compliances CAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792 Miami-Dade County-Dade Product Control Approved

ROOF SHINGLES FEATURING SCOTCHGARD™ PROTECTOR

www.AtlasRoofing.com

Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyClass 4 Impact ResistanceManufactured Using SBS AsphaltUp To 20 Year Peace of Mind

ASTMD 7158-06, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance2218, Class 4 Impact Resistance

Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

Featuring

Length: 22 11/16" / 576.3 mmWidth: 18 1/2" / 469.9 mmExposure: 8 1/2" / 215.9 mmShingles Per Bundle: 25

COLORS: Blackstone Slate(A), Chalkstone Slate(A), Emerald Slate(A), Hearthstone Slate(A), Pewter Slate(A), Weathered Slate(A)

MIAMI-DADE

APPROVED

Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyClass 4 Impact ResistanceManufactured Using SBS AsphaltUp To 20 Year Peace of Mind

ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018 Type 1D 3161, Class F, Tested at 110 mphD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance2218, Class 4 Impact Resistance

Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

Featuring

COLORS: Black Shadow(D), Burnt Sienna(D), Desert Shake(D), Hearthstone Gray(D), Heatherblend(D), Highland Brown(D), Majestic Shake(D), Pewter(D), Weathered Wood(D)

Length: 38 1/4" / 972 mmWidth: 13 1/8" / 333.4 mmExposure: 5 5/8" / 142.9 mmShingles Per Bundle: 22

MIAMI-DADE

APPROVED

COLORS: Pristine Black(D, F, M), Pristine Desert(D, F, M), Pristine Dove(D, F, M), Pristine Green(F, M), Pristine Hearthstone(D, F, M), Pristine Heather(D, F, M), Pristine Hickory(D), Pristine Oyster(M), Pristine Pewter (F), Pristine Sienna(D, F, M), Pristine Tan(M), Pristine Weathered(D, F, M), Pristine Weathered Shadow(M)

Length: 38 1/4" / 972 mmWidth: 13 1/8" / 333.4 mmExposure: 5 5/8" / 142.9 mmShingles Per Bundle: 22 MIAMI-DADE

APPROVED

Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind

ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance

Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

Featuring

Featuring

D - DAINGERFIELD, TX F - FRANKLIN, OH H - HAMPTON, GA M - MERIDIAN, MSA - ARDMORE, OK

Plant Manufacturing Locations Key

* SEE ATLAS LIMITED WARRANTY FOR ALL SYSTEM AND COVERAGE REQUIREMENTS. ATLAS PRO-CUT® HIP & RIDGE FEATURING SCOTCHGARD™ PROTECTOR MUST BE INSTALLED ON THE ROOF RIDGE FOR THE LIFETIME LIMITED WARRANTY AGAINST ALGAE GROWTH TO BE VALID.

Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind

ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance

Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

MIAMI-DADE

APPROVED

Length: 39 3/8" / 1000.1 mmWidth: 14" / 355.6 mmExposure: 6" / 152.4 mmShingles Per Bundle: 20

COLORS: Pristine Black(H), Pristine Desert(H), Pristine Dove(H), Pristine Hearthstone(H), Pristine Heather(H), Pristine Pewter(H), Pristine Sienna(H), Pristine Weathered(H)

Page 4: PRODUCT GUIDE · 2218, Class 4 Impact Resistance Codes and Compliances CAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792 Miami-Dade County-Dade Product Control Approved

ROOF SHINGLES

Features & BenefitsAlgae Resistant Shingle30 Year* Limited Warranty60 MPH Limited Wind WarrantyUp To 10 Year Peace of Mind

ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Type 1, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance

Codes and CompliancesCAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

MIAMI-DADE

APPROVED

MIAMI-DADE

APPROVED

Length: 36" / 914.4 mWidth: 12" / 304.8 mmExposure: 5" / 127 mmShingles Per Bundle: 26

Features & BenefitsAlgae Resistant ShingleLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind

ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance

Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

MIAMI-DADE

APPROVED

Length: 38 1/4" / 972 mmWidth: 13 1/8" / 333.4 mmExposure: 5 5/8" / 142.9 mmShingles Per Bundle: 22

COLORS: Black Shadow(D, F, M), Weathered Wood(D, F, M)

COLORS: Black Shadow(A, H), Burnt Sienna(A, H), Desert Shake(A, H), Dove Gray(H), Hearthstone Gray(A, H), Heatherblend(A, H), Oyster Shell(H), Pewter(A), Silver White(A, H), Tan Mist(H), Weathered Wood(A, H), Woodland Green(A),

Features & BenefitsAlgae Resistant ShingleLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind

ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance

Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

Length: 39 3/8” / 1000.1 mmWidth: 14” / 355.6 mmExposure: 6” / 152.4 mmShingles Per Bundle: 20

COLORS: Black Shadow(H), Weathered Wood(H)

Features & Benefits20 Year* Limited Warranty60 MPH Limited Wind WarrantySBS Modified Asphalt Wind Sealant3M Ceramic Coated Granules

ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Type 1, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance

UL790, Class A Fire Resistance2390, Class H Wind Resistance

Codes and CompliancesCAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved

MIAMI-DADE

APPROVED

Length: 36" / 914.4 mWidth: 12" / 304.8 mmExposure: 5" / 127 mmShingles Per Bundle: 25

COLORS: Black Shadow(A, H), Weathered Wood(A, H)

Page 5: PRODUCT GUIDE · 2218, Class 4 Impact Resistance Codes and Compliances CAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792 Miami-Dade County-Dade Product Control Approved

www.AtlasRoofing.com

Dimensions: 12" x 12"

Exposure: 5 5/8"

Coverage: 31 Lineal Feet

Shingles Per Package: 66

ASTM

D 3018, Type I

D 3462, As Manufactured

E 108, Class A Fire Resistance

UL

790, Class A Fire Resistance

2218, Class 4 Impact Resistance**

Codes and Compliances

Florida Building Code Approved - FL 9792

Miami-Dade Compliance Requirements

NOA No. 07-0927.06 (StormMaster® Slate)

NOA No. 05-0120.02 (StormMaster® Shake)

NOA No. 05-0120.03 (Pinnacle®)

Matches Wind Performance of Atlas Field Shingles

ROOF SHINGLE ACCESSORIES

MIAMI-DADE

APPROVED

HIP & RIDGE SHINGLEFeaturing

Starter StripShingle Dimensions: 7 1/2" x 36" nominal

Exposure Limits: Up To 6"

Per Bundle: 118 Linear Feet

Starter Strip RollRoll Dimensions: 7.2" x 33' 4"

Exposure Limits: Up To 6"

Per Roll: 33' 4"

Starter StripShingle Dimensions: 10 1/2" x 22 11/16"

Exposure Limits: Up To 8 1/2"

Per Bundle: 79 Linear Feet

STARTER STRIP

** SBS AVAILABLE FROM THE ARDMORE, OK MANUFACTURING PLANT ONLY

Product Specifications

Length: 144'

Width: 36"

Square Per Roll Coverage: 4

Square Feet Per Roll: 432

Codes & Compliances

ASTM D 4869, Type II

ASTM D 226, Type I

Florida Building Code Approved - FL 11915

Product Specifications

Length: 141.5'

Width: 36"

Square Per Roll Coverage: 4

Coverage with 2" Lap: 400 Square Feet

Codes & Compliances

UL Classified as a Roofing Accessory

ASTM D 6757

Florida Building Code Approved - FL 11915

Also Meets Performance Characteristics of ASTM D 4869 (#15 & #30 Standard)

Product Specifications

Length: 72'

Width: 36"

Square Per Roll Coverage: 2

Square Feet Per Roll: 216

Codes & Compliances

ASTM D 4869, Type IV

ASTM D 226, Type II

Florida Building Code Approved - FL 11915

HIGH PERFORMANCE UNDERLAYMENTS

#15 Specification Felt#30 Specification Felt

NOTE: See Pro-Cut® Hip & Ridge data sheet for color matches.

** **

Length: 250' Width: 48"

Codes & Compliances

AC 207, Ultraviolet Exposure for 6 months

AC 207, Accelerated Aging

ASTM D 108, Fire Resistance

ASTM D 6757, Inorganic shingle underlayment standard

Performance characteristics exceed - ASTM D 4869, Type l, Type ll, Type lll, Type lV , (Standard specification for asphalt saturated felt), ASTM D 226 Type I & Type II

UL 790, Fire resistance

UL Classified as a Prepared Roofing Accessory

Florida Building Code Approved - FL 11915

Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 07-0927.05, 12/27/12

MIAMI-DADE

APPROVED

Square Per Roll Coverage: 10 Coverage with 4" Lap: 917 sq. ft

Page 6: PRODUCT GUIDE · 2218, Class 4 Impact Resistance Codes and Compliances CAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792 Miami-Dade County-Dade Product Control Approved

© Copyright 2012, Atlas Roofing Corporation ATL-121609-01 3/12

Product Specifications

Length: 36'

Width: 36"

Square Per Roll Coverage: 1

Square Feet Per Roll: 108

Codes & Compliances

ASTM D 6380, Class M

Also available non-ASTM

Florida Building Code Approved - FL 11915

Product Specifications

Length: 36'

Width: 36"

Square Per Roll Coverage: 1

Square Feet Per Roll: 108

Codes & Compliances

Florida Building Code Approved - FL 11915

MINERAL SURFACE ROLL

Slate/Tile Underlayment #90 Mineral Surface Roll

www.AtlasRoofing.com

CORPORATE SALES & MARKETING2000 RiverEdge Parkway, Suite 800Atlanta, Georgia 30328

SALES OFFICES

Ardmore, OK(800) 261-2852FAX (580) 223-6894

Daingerfield, TX(800) 270-2852FAX (903) 645-2291

Franklin, OH(800) 260-2852FAX (937) 746-6040

Hampton, GA(800) 251-2852FAX (770) 946-5249

Meridian, MS(800) 933-2721FAX (601) 483-7344

SBS PEEL & STICK UNDERLAYMENTS

Product Specifications

Length: 33.3' (1 sq.) 72.1' (2 sq.)

Width: 36"

Square Per Roll Coverage: 1 / 2

Standards & Code Listings

Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering

ASTM D 1970 Standard Ice Dam Underlayment

ICC-ES Report ER 1783

Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 & 31D-2

Florida Building Code Approved - FL 11915

Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 08-1006.03, 1/26/14

Product Specifications

Length: 66.6'

Width: 36"

Square Per Roll Coverage: 2

Standards & Code Listings

Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering

ASTM D 1970 Standard Ice Dam Underlayment

ICC-ES Report ER 1783

Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 and 31D-2

Florida Building Code Approved - FL 11915

Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 08-1006.03, 1/26/14

Product Specifications

Length: 66.6'

Width: 36"

Square Per Roll Coverage: 2

Standards & Code Listings

Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering

ASTM D 1970 Standard Ice Dam Underlayment

ICC-ES Report ER 1783

Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 and 31D-2

Florida Building Code Approved - FL 11915

Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 08-1006.03, 1/26/14

Product Specifications

Length: 72'

Width: 36"

Square Per Roll Coverage: 2

Standards & Code Listings

Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering

ASTM D 1970 Standard Ice Dam Underlayment

Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 and 31D-2

Miami-Dade County TAS 103 Stack Test

Florida Building Code Approved - FL 11915

Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 09-0707.04, 7/31/12

MIAMI-DADE

APPROVED

MIAMI-DADE

APPROVED

MIAMI-DADE

APPROVED

MIAMI-DADE

APPROVED

HIGH TEMPERATURE UNDERLAYMENTSelf-Adhering Underlayment for Metal and All Other Types of Roofing Systems

Product Specifications

Length: 72'

Width: 36"

Square Per Roll Coverage: 2

Square Feet Per Roll: 216

Codes & Compliances

ASTM D 4869

Florida Building Code Approved - FL 11915

Product Specifications

Length: 144'

Width: 36"

Square Per Roll Coverage: 4

Square Feet Per Roll: 432

Codes & Compliances

ASTM D 4869, Type I

Florida Building Code Approved - FL 11915

ASPHALT SATURATED ORGANIC FELT

#30 Saturated Felt #15 Saturated Felt