product guide · 2218, class 4 impact resistance codes and compliances can/csa-a123.5-m90 florida...
TRANSCRIPT
www.AtlasRoofing.com
SHINGLES, UNDERLAYMENTS & ACCESSORIES
PRODUCT GUIDE
Shingles
Underlayments
Hip & Ridge
Starter Strips
YOUR ROOF SHOULD BEAN ATLAS SYSTEM
Designer Shingles StormMaster® Slate StormMaster® Shake Pinnacle® featuring Scotchgard™ Protector Pinnacle® HP featuring Scotchgard™ Protector Pinnacle® Pinnacle® HP GlassMaster®
Hip & Ridge Pro-Cut® Hip & Ridge
Underlayment Gorilla Guard® Summit® Synthetic WeatherMaster® #30 Saturated Felt
Starter Strips Pro-Cut® Starter Strip
Roofing SystemRoofing System Atlas Signature Select® is a cohesive roofing system, who's components are specifically chosen to work together. That's why we'll
UPGRADE your roof's Premium Protection Period when you install Atlas qualifying roof components.
ROOF SHINGLES FEATURING SCOTCHGARD™ PROTECTOR
www.AtlasRoofing.com
Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyClass 4 Impact ResistanceManufactured Using SBS AsphaltUp To 20 Year Peace of Mind
ASTMD 7158-06, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance2218, Class 4 Impact Resistance
Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
Featuring
Length: 22 11/16" / 576.3 mmWidth: 18 1/2" / 469.9 mmExposure: 8 1/2" / 215.9 mmShingles Per Bundle: 25
COLORS: Blackstone Slate(A), Chalkstone Slate(A), Emerald Slate(A), Hearthstone Slate(A), Pewter Slate(A), Weathered Slate(A)
MIAMI-DADE
APPROVED
Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyClass 4 Impact ResistanceManufactured Using SBS AsphaltUp To 20 Year Peace of Mind
ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018 Type 1D 3161, Class F, Tested at 110 mphD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance2218, Class 4 Impact Resistance
Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
Featuring
COLORS: Black Shadow(D), Burnt Sienna(D), Desert Shake(D), Hearthstone Gray(D), Heatherblend(D), Highland Brown(D), Majestic Shake(D), Pewter(D), Weathered Wood(D)
Length: 38 1/4" / 972 mmWidth: 13 1/8" / 333.4 mmExposure: 5 5/8" / 142.9 mmShingles Per Bundle: 22
MIAMI-DADE
APPROVED
COLORS: Pristine Black(D, F, M), Pristine Desert(D, F, M), Pristine Dove(D, F, M), Pristine Green(F, M), Pristine Hearthstone(D, F, M), Pristine Heather(D, F, M), Pristine Hickory(D), Pristine Oyster(M), Pristine Pewter (F), Pristine Sienna(D, F, M), Pristine Tan(M), Pristine Weathered(D, F, M), Pristine Weathered Shadow(M)
Length: 38 1/4" / 972 mmWidth: 13 1/8" / 333.4 mmExposure: 5 5/8" / 142.9 mmShingles Per Bundle: 22 MIAMI-DADE
APPROVED
Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind
ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance
Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
Featuring
Featuring
D - DAINGERFIELD, TX F - FRANKLIN, OH H - HAMPTON, GA M - MERIDIAN, MSA - ARDMORE, OK
Plant Manufacturing Locations Key
* SEE ATLAS LIMITED WARRANTY FOR ALL SYSTEM AND COVERAGE REQUIREMENTS. ATLAS PRO-CUT® HIP & RIDGE FEATURING SCOTCHGARD™ PROTECTOR MUST BE INSTALLED ON THE ROOF RIDGE FOR THE LIFETIME LIMITED WARRANTY AGAINST ALGAE GROWTH TO BE VALID.
Features & BenefitsPristine Shingle Featuring Scotchgard™ ProtectorLifetime* Limited Warranty Against Algae GrowthLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind
ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance
Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
MIAMI-DADE
APPROVED
Length: 39 3/8" / 1000.1 mmWidth: 14" / 355.6 mmExposure: 6" / 152.4 mmShingles Per Bundle: 20
COLORS: Pristine Black(H), Pristine Desert(H), Pristine Dove(H), Pristine Hearthstone(H), Pristine Heather(H), Pristine Pewter(H), Pristine Sienna(H), Pristine Weathered(H)
ROOF SHINGLES
Features & BenefitsAlgae Resistant Shingle30 Year* Limited Warranty60 MPH Limited Wind WarrantyUp To 10 Year Peace of Mind
ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Type 1, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance
Codes and CompliancesCAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
MIAMI-DADE
APPROVED
MIAMI-DADE
APPROVED
Length: 36" / 914.4 mWidth: 12" / 304.8 mmExposure: 5" / 127 mmShingles Per Bundle: 26
Features & BenefitsAlgae Resistant ShingleLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind
ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance
Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
MIAMI-DADE
APPROVED
Length: 38 1/4" / 972 mmWidth: 13 1/8" / 333.4 mmExposure: 5 5/8" / 142.9 mmShingles Per Bundle: 22
COLORS: Black Shadow(D, F, M), Weathered Wood(D, F, M)
COLORS: Black Shadow(A, H), Burnt Sienna(A, H), Desert Shake(A, H), Dove Gray(H), Hearthstone Gray(A, H), Heatherblend(A, H), Oyster Shell(H), Pewter(A), Silver White(A, H), Tan Mist(H), Weathered Wood(A, H), Woodland Green(A),
Features & BenefitsAlgae Resistant ShingleLifetime* Limited WarrantyUp To 130 MPH Limited Wind WarrantyUp To 15 Year Peace of Mind
ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance
Codes and CompliancesCAN/CSA-A123.5-M90Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
Length: 39 3/8” / 1000.1 mmWidth: 14” / 355.6 mmExposure: 6” / 152.4 mmShingles Per Bundle: 20
COLORS: Black Shadow(H), Weathered Wood(H)
Features & Benefits20 Year* Limited Warranty60 MPH Limited Wind WarrantySBS Modified Asphalt Wind Sealant3M Ceramic Coated Granules
ASTMD 7158, Class H Wind Resistance, Passed at 150 mphD 6381, Uplift ResistanceD 3018, Type 1D 3161, Type 1, Class F, Tested at 110 MPHD 3462, As ManufacturedE 108, Class A Fire Resistance
UL790, Class A Fire Resistance2390, Class H Wind Resistance
Codes and CompliancesCAN/CSA-A123.5-M90 Florida Building Code Approved – FL 9792Miami-Dade County-Dade Product Control Approved
MIAMI-DADE
APPROVED
Length: 36" / 914.4 mWidth: 12" / 304.8 mmExposure: 5" / 127 mmShingles Per Bundle: 25
COLORS: Black Shadow(A, H), Weathered Wood(A, H)
www.AtlasRoofing.com
Dimensions: 12" x 12"
Exposure: 5 5/8"
Coverage: 31 Lineal Feet
Shingles Per Package: 66
ASTM
D 3018, Type I
D 3462, As Manufactured
E 108, Class A Fire Resistance
UL
790, Class A Fire Resistance
2218, Class 4 Impact Resistance**
Codes and Compliances
Florida Building Code Approved - FL 9792
Miami-Dade Compliance Requirements
NOA No. 07-0927.06 (StormMaster® Slate)
NOA No. 05-0120.02 (StormMaster® Shake)
NOA No. 05-0120.03 (Pinnacle®)
Matches Wind Performance of Atlas Field Shingles
ROOF SHINGLE ACCESSORIES
MIAMI-DADE
APPROVED
HIP & RIDGE SHINGLEFeaturing
Starter StripShingle Dimensions: 7 1/2" x 36" nominal
Exposure Limits: Up To 6"
Per Bundle: 118 Linear Feet
Starter Strip RollRoll Dimensions: 7.2" x 33' 4"
Exposure Limits: Up To 6"
Per Roll: 33' 4"
Starter StripShingle Dimensions: 10 1/2" x 22 11/16"
Exposure Limits: Up To 8 1/2"
Per Bundle: 79 Linear Feet
STARTER STRIP
** SBS AVAILABLE FROM THE ARDMORE, OK MANUFACTURING PLANT ONLY
Product Specifications
Length: 144'
Width: 36"
Square Per Roll Coverage: 4
Square Feet Per Roll: 432
Codes & Compliances
ASTM D 4869, Type II
ASTM D 226, Type I
Florida Building Code Approved - FL 11915
Product Specifications
Length: 141.5'
Width: 36"
Square Per Roll Coverage: 4
Coverage with 2" Lap: 400 Square Feet
Codes & Compliances
UL Classified as a Roofing Accessory
ASTM D 6757
Florida Building Code Approved - FL 11915
Also Meets Performance Characteristics of ASTM D 4869 (#15 & #30 Standard)
Product Specifications
Length: 72'
Width: 36"
Square Per Roll Coverage: 2
Square Feet Per Roll: 216
Codes & Compliances
ASTM D 4869, Type IV
ASTM D 226, Type II
Florida Building Code Approved - FL 11915
HIGH PERFORMANCE UNDERLAYMENTS
#15 Specification Felt#30 Specification Felt
NOTE: See Pro-Cut® Hip & Ridge data sheet for color matches.
** **
Length: 250' Width: 48"
Codes & Compliances
AC 207, Ultraviolet Exposure for 6 months
AC 207, Accelerated Aging
ASTM D 108, Fire Resistance
ASTM D 6757, Inorganic shingle underlayment standard
Performance characteristics exceed - ASTM D 4869, Type l, Type ll, Type lll, Type lV , (Standard specification for asphalt saturated felt), ASTM D 226 Type I & Type II
UL 790, Fire resistance
UL Classified as a Prepared Roofing Accessory
Florida Building Code Approved - FL 11915
Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 07-0927.05, 12/27/12
MIAMI-DADE
APPROVED
Square Per Roll Coverage: 10 Coverage with 4" Lap: 917 sq. ft
© Copyright 2012, Atlas Roofing Corporation ATL-121609-01 3/12
Product Specifications
Length: 36'
Width: 36"
Square Per Roll Coverage: 1
Square Feet Per Roll: 108
Codes & Compliances
ASTM D 6380, Class M
Also available non-ASTM
Florida Building Code Approved - FL 11915
Product Specifications
Length: 36'
Width: 36"
Square Per Roll Coverage: 1
Square Feet Per Roll: 108
Codes & Compliances
Florida Building Code Approved - FL 11915
MINERAL SURFACE ROLL
Slate/Tile Underlayment #90 Mineral Surface Roll
www.AtlasRoofing.com
CORPORATE SALES & MARKETING2000 RiverEdge Parkway, Suite 800Atlanta, Georgia 30328
SALES OFFICES
Ardmore, OK(800) 261-2852FAX (580) 223-6894
Daingerfield, TX(800) 270-2852FAX (903) 645-2291
Franklin, OH(800) 260-2852FAX (937) 746-6040
Hampton, GA(800) 251-2852FAX (770) 946-5249
Meridian, MS(800) 933-2721FAX (601) 483-7344
SBS PEEL & STICK UNDERLAYMENTS
Product Specifications
Length: 33.3' (1 sq.) 72.1' (2 sq.)
Width: 36"
Square Per Roll Coverage: 1 / 2
Standards & Code Listings
Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering
ASTM D 1970 Standard Ice Dam Underlayment
ICC-ES Report ER 1783
Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 & 31D-2
Florida Building Code Approved - FL 11915
Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 08-1006.03, 1/26/14
Product Specifications
Length: 66.6'
Width: 36"
Square Per Roll Coverage: 2
Standards & Code Listings
Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering
ASTM D 1970 Standard Ice Dam Underlayment
ICC-ES Report ER 1783
Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 and 31D-2
Florida Building Code Approved - FL 11915
Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 08-1006.03, 1/26/14
Product Specifications
Length: 66.6'
Width: 36"
Square Per Roll Coverage: 2
Standards & Code Listings
Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering
ASTM D 1970 Standard Ice Dam Underlayment
ICC-ES Report ER 1783
Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 and 31D-2
Florida Building Code Approved - FL 11915
Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 08-1006.03, 1/26/14
Product Specifications
Length: 72'
Width: 36"
Square Per Roll Coverage: 2
Standards & Code Listings
Underwriters Laboratories Class A and Class C Fire Rating – Based on Roof Covering
ASTM D 1970 Standard Ice Dam Underlayment
Uniform Building Code Nos. 32B-1, 32B-2, 32D-1 and 31D-2
Miami-Dade County TAS 103 Stack Test
Florida Building Code Approved - FL 11915
Miami-Dade County Product Control Approved, Miami-Dade County, Florida, NOA No. 09-0707.04, 7/31/12
MIAMI-DADE
APPROVED
MIAMI-DADE
APPROVED
MIAMI-DADE
APPROVED
MIAMI-DADE
APPROVED
HIGH TEMPERATURE UNDERLAYMENTSelf-Adhering Underlayment for Metal and All Other Types of Roofing Systems
Product Specifications
Length: 72'
Width: 36"
Square Per Roll Coverage: 2
Square Feet Per Roll: 216
Codes & Compliances
ASTM D 4869
Florida Building Code Approved - FL 11915
Product Specifications
Length: 144'
Width: 36"
Square Per Roll Coverage: 4
Square Feet Per Roll: 432
Codes & Compliances
ASTM D 4869, Type I
Florida Building Code Approved - FL 11915
ASPHALT SATURATED ORGANIC FELT
#30 Saturated Felt #15 Saturated Felt