product guide mass save utility incentives for light fixtures and
TRANSCRIPT
Product Guide Mass Save Utility Incentives for Light Fixtures and Controls
February 19, 2013 617. 788. 2400
2013
Utility Incentive Compliant Products
Code 21Compact Fluorescent Fixtureand Dimmable Compact Fluorescent Fixture
Min Watts Saved (retro only): 35
To be eligible for incentives, all fixtures must be hard‐wired and have electronic ballasts with <33% THD. (Retrofit kits and screw‐in adapters not eligible)
Catalog Number
DownlightDescription Efficiency
Downlight ‐ Horizontal
LF8 1/26‐42TRT MVOLT F8O1AZ 8" 1 Lamp 26W‐42W TRT Electronic Ballast Open Clear Specular Trim
67%
LF6 2/26DTT MVOLT F6O2A 6" 2 Lamp 26DTT Electronic Ballast Open Clear Diffuse Trim 47%
LF8 2/26DTT MVOLT F8O2AZ 8" 2 Lamp 26DTT Electronic Ballast Open Clear Specular Trim 61%
Downlight ‐ Vertical
LP6F 26‐42TRT MVOLT 6O7AZ 6" 1 Lamp 26W‐42W TRT Electronic Ballast Open Clear Specular Trim
53%
Downlight ‐ Vertical
RT10V(113‐70EX)/1010SG 10" 1 Lamp 13‐70w CFL Electronic Ballast Open Clear Trim
RT12V(113‐70EX)/1210SG 12" 1 Lamp 13‐70w CFL Electronic Ballast Open Clear Trim
Catalog Number
Downlight RetrofitDescription Efficiency
Downlight ‐ Vertical
IF4R 13 E/ICFR49WW 4" 1 Lamp 26DTT Electronic Ballast Open Clear Specular, White Trim
Downlight ‐ Horizontal
RT8H(213‐42EX)/8615SG 8" 2 Lamp 13‐42w CFL Electronic Ballast Open Clear Trim
RT10H(213‐70EX)/9515SG 10" 2 Lamp 13‐70w CFL Electronic Ballast Open Clear Trim
RT12H(213‐70EX)/1410SG 12" 2 Lamp 13‐70w CFL Electronic Ballast Open Clear Trim
Downlight ‐ Vertical
RT5V(113‐42EX)/5315SG 5" 1 Lamp 13‐42w CFL Electronic Ballast Open Clear Trim
Tuesday, February 19, 2013 Page 2 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 21Compact Fluorescent Fixtureand Dimmable Compact Fluorescent Fixture
Min Watts Saved (retro only): 35
To be eligible for incentives, all fixtures must be hard‐wired and have electronic ballasts with <33% THD. (Retrofit kits and screw‐in adapters not eligible)
Catalog Number
Downlight RetrofitDescription Efficiency
Downlight ‐ Vertical
SGRT6V(113‐42EX)/6415SG 6" 1 Lamp 13‐42w CFL Electronic Ballast Open Clear Trim
Catalog Number
SconceDescription Efficiency
1500 Series Sconce
1538 13Q ES3 1 Lamp 13W CFL Electronic Ballast Single Switched ADA, Cast, faux alabaster resin sconce
1300 Series Sconce
1350 PB 213 ELB‐H 2 Lamp 26DTT Electronic Ballast Single Switched ADA
1200 Series Sconce
1215 15 CRM PB 218Q 2 Lamp 18W CFL Electronic Ballast Single Switched ADA
Catalog Number
Semi‐Flush Pendant MountedDescription Efficiency
2100 Series
2174 BN 226Q HPF 2 Lamp 26DTT Electronic Ballast Single Switched
Catalog Number
Surface CeilingDescription Efficiency
2000 Series Designer
Tuesday, February 19, 2013 Page 3 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 21Compact Fluorescent Fixtureand Dimmable Compact Fluorescent Fixture
Min Watts Saved (retro only): 35
To be eligible for incentives, all fixtures must be hard‐wired and have electronic ballasts with <33% THD. (Retrofit kits and screw‐in adapters not eligible)
Catalog Number
Surface CeilingDescription Efficiency
2000 Series Designer
2062 16 BN 13 ELB‐H 16.25" 1 Lamp 13W CFL Electronic Ballast Single Switched
2000 Series Ceiling ‐ Utility / Drum
2050 11 218Q WA 11.5" 2 Lamp 18W CFL Electronic Ballast Single Switched
Tuesday, February 19, 2013 Page 4 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 25LED or LEC (Electroluminescence) Exit Fixtures
Min Watts Saved (retro only): 15
All materials and assembled units shall comply with all applicable codes and standards including (but not limited to) Federal/State/Local building, fire, and electrical codes, and may require designated egress lighting to comply with such codes. Exit sign retrofit kits are not eligible.
Catalog Number
ExitDescription Efficiency
Precise Series Edge‐Lit
LRP 2 RMR 120/277 LED Double Face
LRP 2 RMR 120/277 EL N LED Double Face, Battery Backup
Contractor Select Edge‐Lit
EDG 2 R LED Double Face
EDG 2 R EL LED Double Face, Battery Backup
Extreme Vandal‐Resistant Cast Aluminum
LV S W 1 R 120/277 LED Single Face
LV S W 1 R 120/277 EL N CW LED Single Face, Battery Backup, Cold Weather
Signature Die‐cast Aluminum
LE S W 2 R 120/277 LED Double Face
LE S W 2 R 120/277 EL N LED Double Face, Battery Backup
Quantum Thermoplastic
LQM S W 3 R 120/277 LED Double Face
LQM S W 3 R 120/277 EL N LED Double Face, Battery Backup
Contractor Select Thermoplastic
EXR LED Double Face
EXR EL LED Double Face, Battery Backup
Tuesday, February 19, 2013 Page 5 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 30AHigh Efficiency 2 lamp Prismatic Lensed Fluorescent Fixtures – 2x2 or 2x4
Min Watts Saved (retro only): 27
Overall fixture efficiency must be > :– 83% for 2x4 prismatic lensed fixture with two T‐8 or T‐5 lamps;– 75% for 2x2 prismatic lensed fixture with two T‐8 or T‐5 lamps (reduced wattage biax lamps are eligible‐ 28 watts or less).
Catalog Number
TrofferDescription Efficiency
Recessed Grid
2GT8 2 32 A12 MVOLT BILP BC30 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 87%
Recessed Spec Grade
2SP8 G 2 17 A12 MVOLT BINP 2' x 2' 2 Lamp 17W HPT8 CEE1 Ballast Single Switched 75%
2SP8 G 2 32 A12 MVOLT BILP 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 86%
Tuesday, February 19, 2013 Page 6 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 30BHigh Efficiency 2 lamp Parabolic Fluorescent Fixtures – 2x2 or 2x4
Min Watts Saved (retro only): 27
Overall fixture efficiency must be > :– 80% for 2x4 fixture with parabolic louver (2” to 3” deep cells) with two T‐8 or T5 lamps;– 80% for 2x2 fixture with parabolic louver (2” to 3” deep cells) with two T‐8 or T5 lamps (reduced wattage biax lamps are eligible‐ 28 watts or less).
Catalog Number
ParabolicDescription Efficiency
ES8P Series (Fixture)
2ES8P 217 BILP L835HT8 2' x 2' 2 Lamp 17W HPT8 CEE1 Ballast Single Switched High Performance Energy‐Saving T8 Louvered
84%
2ES8P 2 32 BILP L835HT8 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched High Performance Energy‐Saving T8 Louvered
86%
Tuesday, February 19, 2013 Page 7 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 30CHigh Efficiency up to 2 lamp Recessed Indirect/Direct Fluorescent Fixtures – 2x2 or 2x4
Min Watts Saved (retro only): 27
Overall fixture efficiency must be > :– 75% for 2x4 recessed indirect/direct fixture with two T‐8 or T‐5 lamps;– 70% for 2x2 recessed indirect/direct fixture with two T‐8, T‐5, or T5HO lamps (only reduced wattage biax lamps are eligible‐ 28 watts or less).
Catalog Number
Recessed IndirectDescription Efficiency
Avante SBL
2AV G 2 CF40 SBL MVOLT GEB10RS 2' x 2' 2 Lamp 28W BIAX CEE1 Ballast Single Switched 71%
Meridian
MD 22 G9 2 T5 EBPR MVOLT SWS 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 76%
MD 22 G9 2 T5HO EBPR MVOLT SWS 2' x 2' 2 Lamp 24W T5HO Program Start Ballast Single Switched 77%
MD 22 G9 2 T5HO EBPR MVOLT SWR 2' x 2' 2 Lamp 24W T5HO Program Start Ballast Single Switched 82%
Portico
POR 24 G9 2 T5HO EBPR MVOLT SWR 2' x 4' 2 Lamp 54W T5HO Program Start Ballast Single Switched 89%
Saros
SR 22 G9 240BX EBPR MVOLT SWS 2' x 2' 2 Lamp 28W BIAX Program Start Ballast Single Switched 76%
SR 22 G9 2T5HO EBPR MVOLT SWS 2' x 2' 2 Lamp 24W T5HO Program Start Ballast Single Switched 77%
Luna
FLU 22 B 2T8 CEE1 G PS WH 2' x 2' 2 Lamp 17W HPT8 CEE1 Ballast Single Switched 70%
FLU 22 B 240BX E G PS WH 2' x 2' 2 Lamp 28W BIAX Program Start Ballast Single Switched 70%
Catalog Number
VolumetricDescription Efficiency
Volumetric Series
2VT8 2 17 ADP MVOLT BINP 2' x 2' 2 Lamp 17W HPT8 CEE1 Ballast Single Switched 80%
Tuesday, February 19, 2013 Page 8 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 31High Efficiency 3 lamp Fluorescent Fixtures – 2x4
Min Watts Saved (retro only): 31
Overall fixture efficiency must be > :– 83% for 2x4 prismatic lensed fixture with three T‐8 or T‐5 lamps;– 75% for 2x4 fixture with parabolic louver (2” to 3” deep cells) with three T‐8 or T5 lamps;– 70% for 2x4 recessed indirect fixture with three T‐8 or T‐5 lamps;Eligible fixtures are limited to 3 lamps with a low power ballast factor < 0.80.
Catalog Number
ParabolicDescription Efficiency
Paramax
2PM3N G B 3 32 18LD MVOLT 1/3 BILP 2' x 4' 3 Lamp 32W HPT8 CEE1 Ballast Single Switched 75%
Catalog Number
TrofferDescription Efficiency
Recessed Grid
2GT8 3 32 A12 MVOLT BILP 1/3 BC30 2' x 4' 3 Lamp 32W HPT8 CEE1 Ballast Single Switched 84%
Recessed Spec Grade
2SP8 G 3 32 A12 MVOLT 1/3 BILP 2' x 4' 3 Lamp 32W HPT8 CEE1 Ballast Single Switched 84%
Tuesday, February 19, 2013 Page 9 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 32 (Retrofit Construction Only)High Efficiency Recessed Fluorescent 2 lamp Retrofit Kits – 2x2 and 2x4
Min Watts Saved (retro only): 27
Overall fixture efficiency must be > :‐ 80% for 2x4 parabolic retrofit kit and advanced glare reducing diffuser retrofit kit with two T‐8 or T‐5 lamps; ‐ 80% for 1x4 parabolic retrofit kit and advanced glare reducing diffuser retrofit kit with one or two T‐8 or T‐5 lamps ‐ 75% for 2x2 parabolic retrofit kit and advanced glare reducing diffuser retrofit kit with two T‐8 ,T‐5, orT‐5HO (reduced wattage biax lamps areeligible‐ 28 watts or less)
Catalog Number
ParabolicDescription Efficiency
2ES8R (Retrofit Kit)
2ES8R 2 17 BILP 2' x 2' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched High Performance Relighting for Parabolics
80%
2ES8RT 2 32 BINP 2' x 4' 2 Lamp 32W HPT8 Electronic Ballast Single Switched High Performance Relighting for Lensed Troffers
86%
2ES8R 217 BILP 2' x 2' 2 Lamp 17W HPT8 CEE1 Ballast Single Switched high Power Factor
80%
2ES8R 2 32 BILP 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched High Performance Relighting for Parabolics
85%
Catalog Number
VolumetricDescription Efficiency
RT5R (Retrofit Kit)
2RT5R 14T5 MVOLT GEB115 LP835 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 85%
2RT5R 28T5 MVOLT GEB95 LPM835P 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 88%
RT8 (Retrofit Kit)
2RT8R 2 32 BILP 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched Relighting for Parabolics Relighting for Parabolics
80%
2RT8RT 2 32 BILP 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched Relighting for Lensed Troffers
80%
Tuesday, February 19, 2013 Page 10 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 33 (New Construction Only)High Efficiency Indirect Low Glare Pendant Fluorescent Fixtures
Min Watts Saved (retro only):
Overall fixture efficiency must exceed:‐ 80% for an Indirect pendant fixture with two T‐8 or T‐5 lamps or one T‐5HO lamp. Fixtures may have adown‐light component of no greater than 45%. Fixtures with a down‐light component must incorporate glare limiting louvers or a perforated cover shielding the lamps. Fixtures must be installed at a lighting power density 10% below current building codes. Ceiling finish must be white and unobstructed
Catalog Number
Linear Suspended Direct/IndirectDescription Efficiency
Twelve
FTWS PB 1T5HO 1C 120 S C24 WH 4` 4' 1 Lamp 54W T5HO Program Start Ballast Single Switched 90%
SAE P‐ID‐9800
P ID 9824T8 PBCWM TCWM LP/HPN 1CWQ FAI/ACC 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 88%
BLS‐P ID 9824T8 PBSS TCWM OSRAM/ELB 1CWQ FAI/ACC 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched Stock Item 83%
Catalog Number
Linear Suspended IndirectDescription Efficiency
Lightedge Curved ‐ Shallow Indirect
EGSCM1 2 28T5 4FT R4 277 GEB10 SCT L/LP F1/24 C100 ACG 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 84%
Lightedge Angular ‐ Deep Indirect
EGAM1 2 28T5 4FT R4 277 GEB10 SCT L/LP F1/24 C100 ACG 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 84%
Bruno ‐ Indirect
BRM1 1 54T5HO SPR 4FT R4 277 GEB10 SCT L/LP F1/24 C210 ACG
4' 1 Lamp 54W T5HO Program Start Ballast Single Switched 88%
Aero ‐ Indirect‐Open
AEM2 2 28T5 WHR 4FT R4 277 GEB10 SCT L/LP F1/24 C110 ACG 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 85%
Avenue E
FAVAS SD 1T5HO 1C 120 S C24 WH 4` 4' 1 Lamp 54W T5HO Program Start Ballast Single Switched 86%
Verve II
Tuesday, February 19, 2013 Page 11 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 33 (New Construction Only)High Efficiency Indirect Low Glare Pendant Fluorescent Fixtures
Min Watts Saved (retro only):
Overall fixture efficiency must exceed:‐ 80% for an Indirect pendant fixture with two T‐8 or T‐5 lamps or one T‐5HO lamp. Fixtures may have adown‐light component of no greater than 45%. Fixtures with a down‐light component must incorporate glare limiting louvers or a perforated cover shielding the lamps. Fixtures must be installed at a lighting power density 10% below current building codes. Ceiling finish must be white and unobstructed
Catalog Number
Linear Suspended IndirectDescription Efficiency
Verve II
FV2S PS 1T5HO 1C 120 S C24 WH 4` 4' 1 Lamp 54W T5HO Program Start Ballast Single Switched Perforated bottom
97%
SAE P‐ID‐9800
BLS‐P I 98PF24T8 TCWM OSRAM/ELB 1CWQ FAI/ACC 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched Stock Item 84%
Arcos Perf II
P I 5914T5HO TCMW LP/ELB 1CQW FAI/ACC 4' 1 Lamp 54W T5HO Program Start Ballast Single Switched 94%
P I 5924T8 TCMW LP/HPN 1CWQ FAI/ACC 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 96%
Mod‐22
P I 0214T5HO TCWM 120 LP/ELB 2' x 2' 1 Lamp 54W T5HO Program Start Ballast Single Switched 92%
Arcos Slot
P S/I 5424T5 TCMW LP/ELB 1CWQ FAI/ACC 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 93%
P S/I 5414T5HO TCMW LP/ELB 1CWQ FAI/ACC 4' 1 Lamp 54W T5HO Program Start Ballast Single Switched 94%
Tuesday, February 19, 2013 Page 12 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 34Advanced Recessed Fluorescent Fixtures2x2, 1x4 or 2x4
Min Watts Saved (retro only): 33
Overall fixture efficiency must be > : ‐ 85% for 2x4 advanced glare reducing diffuser fixture with one or two T‐8 or T‐5 lamps, or one T‐5HO lamp; ‐ 80% for 1x4 advanced glare reducing diffuser fixture with one or two T‐8 or T‐5 lamps, or one T‐5HO lamp. ‐ 80% for 2x2 advanced glare reducing diffuser fixture with one or two T‐8, T‐5, T‐5HO lamps (reduced wattage biax lamps are eligible‐ 28 watts or less)
Catalog Number
VolumetricDescription Efficiency
RT5
2RT8S 217 MVOLT BINP L835HT8 2' x 2' 2 Lamp 17W HPT8 CEE1 Ballast Single Switched 81%
2RT5S 28T5 MVOLT GEB95 LPM835P 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched Bottom Access
87%
2RT5 14T5 MVOLT GEB115 LP835 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 87%
2RT5S 14T5 MVOLT GEB115 LP835 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 81%
2RT5 28T5 MVOLT GEB95 LPM835P 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 90%
Volumetric Series
2VT8 2 17 ADP MVOLT BINP 2' x 2' 2 Lamp 17W HPT8 CEE1 Ballast Single Switched 80%
2VT5 2 14T5 ADP MVOLT GEB10PS 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 92%
2VT5 2 24T5HO ADP MVOLT GEB10PS 2' x 2' 2 Lamp 24W T5HO Program Start Ballast Single Switched 96%
2VT5 2 14T5 ADP MVOLT GEB10PS 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 92%
2VT5 2 28T5 ADP MVOLT GEB10PS 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 90%
2VT5 2 24T5HO ADP MVOLT GEB10PS 2' x 2' 2 Lamp 24W T5HO Program Start Ballast Single Switched 96%
2VT5 2 28T5 ADP MVOLT GEB10PS 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 90%
Whisper
WHS 24 2T5 EBPR MVOLT SW SW 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 85%
Nol Series
NOL 22 G9 2T5 GEB10RS MVOLT SWF 2' x 2' 2 Lamp 28W T5 Program Start Ballast Single Switched 82%
NOL 22 G9 2T5 GEB10RS MVOLT RCF 2' x 2' 2 Lamp 28W T5 Program Start Ballast Single Switched 87%
NOL 22 G9 2T5 GEB10RS MVOLT RCl 2' x 2' 2 Lamp 28W T5 Program Start Ballast Single Switched 87%
NOL 22 G9 2T5 GEB10RS MVOLT RWF 2' x 2' 2 Lamp 28W T5 Program Start Ballast Single Switched 82%
NOL 22 G9 2T5 GEB10RS MVOLT SCF 2' x 2' 2 Lamp 28W T5 Program Start Ballast Single Switched 84%
NOL 24 G9 2T5 GEB10RS MVOLT RCF 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 86%
NOL 24 G9 2T5 GEB10RS MVOLT SCF 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 86%
NOL 24 G9 2T5 GEB10RS MVOLT RCl 2' x 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 87%
Tuesday, February 19, 2013 Page 13 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 34Advanced Recessed Fluorescent Fixtures2x2, 1x4 or 2x4
Min Watts Saved (retro only): 33
Overall fixture efficiency must be > : ‐ 85% for 2x4 advanced glare reducing diffuser fixture with one or two T‐8 or T‐5 lamps, or one T‐5HO lamp; ‐ 80% for 1x4 advanced glare reducing diffuser fixture with one or two T‐8 or T‐5 lamps, or one T‐5HO lamp. ‐ 80% for 2x2 advanced glare reducing diffuser fixture with one or two T‐8, T‐5, T‐5HO lamps (reduced wattage biax lamps are eligible‐ 28 watts or less)
Catalog Number
VolumetricDescription Efficiency
Datum
DAT RD SS 1X4 G9 1T5 EBPR MVOLT 1' x 4' 1 Lamp 28W T5 Program Start Ballast Single Switched 84%
DAT RT SS 1X4 G9 1T5 EBPR MVOLT 1' x 4' 1 Lamp 28W T5 Program Start Ballast Single Switched 82%
DAT RD SS 2X2 G9 2T5 EBPR MVOLT 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 83%
DAT RT SS 2X2 G9 2T5 EBPR MVOLT 2' x 2' 2 Lamp 14W T5 Program Start Ballast Single Switched 83%
Plano Series Recessed VL Optic
P024 VL T5 1 W UNV E 1 TB 1 Lamp 28W T5 Electronic Ballast Single Switched 87%
P024 VL T5 2 W UNV E 1 TB 2 Lamp 28W T5 Electronic Ballast Single Switched 85%
Tuesday, February 19, 2013 Page 14 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 41Industrial/Commercial Fluorescent Fixtures – 4 ft. and 8 ft. Fixtures
Min Watts Saved (retro only): 23
Overall fixture efficiency must be >: ‐ 85% for Industrial Reflector fixture with T‐8 or T‐5 lamps (up to 20% up‐light); ‐ 83% for Commercial Grade Wraparound fixture with one or two T‐8 or T‐5 lamps.‐ 85% for reflector kits with specular or semi‐specular reflectors Reflector Kits for Existing Fixtures include 2’x2’ and 2’x4’ reflector troffer kits, 4’ and 8’ strip channel, and industrial reflector kits. Applies to fixtures installed at or less than 16 feet above the floor. Only one incentive may be counted per fixture. Eight foot and multiple fixtures served by a single ballast are only eligible for one incentive.
Catalog Number
Industrial ‐ OpenDescription Efficiency
L Series Standard
L232 MV 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 89%
TL232 MV 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 88%
LA 2 32 MVOLT BILP 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 89%
TLA 2 32 MVOLT 1/4 BILP 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 89%
AF Heavy Duty Turret
AF 2 32 MVOLT BILP 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 91%
TAF 2 32 MVOLT 1/4 BILP 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 91%
AF10 2 32 MVOLT BILP 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 91%
TAF10 2 32 MVOLT 1/4 BILP 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 92%
TAFST 2 32 MVOLT 1/4 BILP 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 84%
EJ General Purpose
EJS 2 32 MVOLT BILP 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 89%
TEJS 2 32 MVOLT 1/4 BILP 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 89%
Catalog Number
WrapDescription Efficiency
Standard Box Wrap Series
SB232 MV 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 92%
SB 2 28T5 MVOLT GEB95 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 89%
Low Profile Box Wrap Series
LB 2 28T5 MVOLT GEB95 4' 2 Lamp 28W T5 Program Start Ballast Single Switched 89%
LB232 MV 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 89%
Tuesday, February 19, 2013 Page 15 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 43 (Retrofit Construction Only)Vapor Tight Fluorescent Fixtures– 4 ft. and 8 ft. Fixtures
Min Watts Saved (retro only): 45
Overall fixture efficiency must be > : ‐70% for Vapor Tight fluorescent fixture with one or two T‐8, T‐5, T‐8HO, T‐5HO or 3‐T8 lamps. Typically installed in garage, warehouse, food prep and other industrial applications.
Catalog Number
Industrial ‐ EnclosedDescription Efficiency
Wet Location
XWL232 MV 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 72%
XWL254 MV 4' 2 Lamp 54W T5HO Electronic Ballast Single Switched 70%
Tuesday, February 19, 2013 Page 16 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 44Clean Room Rated Fluorescent Fixtures – 1x4 or 2x4
Min Watts Saved (retro only): 27
Overall fixture efficiency must be >: ‐75% for Clean Room fluorescent fixture with up to three T‐8 or T‐5 lamps. To be eligible for incentives, fixtures must be installed in a clean room rated environment.
Catalog Number
Clean RoomDescription Efficiency
Recessed Cleanroom Troffer
2SRH G 3 32 FSF A12125V MVOLT 1/3 BILP 2' x 4' 3 Lamp 32W HPT8 CEE1 Ballast Single Switched Class 100 & 1,000
75%
Recessed Cleanroom Troffer
2SRT G 2 32 FW A12125V MVOLT BILP 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched Class 10,000 & 100,000
82%
2SRT G 3 32 FW A12125V MVOLT 1/3 BILP 2' x 4' 3 Lamp 32W HPT8 CEE1 Ballast Single Switched Class 10,000 & 100,000
77%
SimpleSeal
CSEFO24‐2‐32‐PB‐1‐2F‐2H‐U‐HE 2' x 4' 2 Lamp 32W HPT8 CEE1 Ballast Single Switched 85%
CSEFO24‐3‐32‐IS‐2‐2F‐2H‐U‐HE 2' x 4' 3 Lamp 32W HPT8 CEE1 Ballast Multi Switched 85%
Tuesday, February 19, 2013 Page 17 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 45 (Retrofit Construction Only)Stairwell Fluorescent fixture ‐ with integral Occupancy sensor controls
Min Watts Saved (retro only): 23
Overall fixture efficiency must be >: ‐75% for Stairwell fluorescent fixture with up to three T‐8 or T‐5 lamps. To be eligible for incentives, fixtures must be installed in a 8,760 hour stairwell application with integral occupancy sensor control setting lights to 50% output in control mode. (Additional controls incentive not available)
Catalog Number
Linear WallDescription Efficiency
FCW Sensored Wall or Ceiling
FCW4 2 32 120 BSNP MSIU 4' 2 Lamp 32W HPT8 Step Dimming Multi Switched Stairwell Fixture with integral occupancy sensor control
85%
Millenium Stretch Series
MLHA1248MS X XX CP 32 SD 1 DV 4' 2 Lamp 32W HPT8 Step Dimming Multi Switched 75%
Nova II Series
N1048MS C 2 32 SD 1 DV 4' 2 Lamp 32W HPT8 Step Dimming Multi Switched 78%
Tuesday, February 19, 2013 Page 18 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 51 (Retrofit Construction Only)Pulse Start Metal Halide Lamp and Electronic Ballast Kits
Min Watts Saved (retro only): 50
All kits must include a new matched Pulse Start Metal Halide Lamp and Electronic Ballast installed per manufacturer’s specifications and applicable codes. Indoor and Outdoor fixtures are eligible.
Catalog Number
Lamp & Ballast KitsDescription Efficiency
Ballast
M175MH‐US‐DD 175W MH Electronic Ballast Ballast requires either Ecopod or Ecobox
M200MH‐US‐DD 200W MH Electronic Ballast Ballast requires either Ecopod or Ecobox
M250MH‐US‐DD 250W MH Electronic Ballast Ballast requires either Ecopod or Ecobox
M320MH‐US‐DD 320W MH Electronic Ballast Ballast requires either Ecopod or Ecobox
M350MH‐US‐DD 350W MH Electronic Ballast Ballast requires either Ecopod or Ecobox
M400MH‐US‐DD 400W MH Electronic Ballast Ballast requires either Ecopod or Ecobox
M450MH‐US‐DD 450W MH Electronic Ballast Ballast requires either Ecopod or Ecobox
Tuesday, February 19, 2013 Page 19 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 52 (Retrofit Construction Only)Pulse Start Metal Halide Fixture with Electronic Ballast
Min Watts Saved (retro only): 64
Only New Metal Halide Pulse Start fixtures with Electronic Ballasts are eligible. Retrofit of existing metal halide fixture of less than 200 watts with new fixture is not eligible. Indoor and Outdoor fixtures are eligible.
Catalog Number
High Bay ‐ HIDDescription Efficiency
Lumen Max Series, Domed Ballast Housing, Aluminum Reflector
ALDDH22MH 250 EX xx xx xx 250W MH Electronic Pulse Start MH
ALDDH22MH 320 EX xx xx xx 320W MH Electronic Pulse Start MH
ALDDH22MH 350 EX xx xx xx 350W MH Electronic Pulse Start MH
ALDDH22MH 400 EX xx xx xx 400W MH Electronic Pulse Start MH
Lumen Max Series, Deco Ballast Housing, Aluminum Reflector
ALDCH22MH 200 EX xx xx xx 200W MH Electronic Pulse Start MH
ALDCH22MH 250 EX xx xx xx 250W MH Electronic Pulse Start MH
ALDCH22MH 320 EX xx xx xx 320W MH Electronic Pulse Start MH
ALDCH22MH 350 EX xx xx xx 350W MH Electronic Pulse Start MH
ALDCH22MH 400 EX xx xx xx 400W MH Electronic Pulse Start MH
Lumen Max Series, Deco Ballast Housing, Prismatic Refractor
PRDCH22MH 250 EX xx xx xx 250W MH Electronic Pulse Start MH
PRDCH22MH 320 EX xx xx xx 320W MH Electronic Pulse Start MH
PRDCH22MH 350 EX xx xx xx 350W MH Electronic Pulse Start MH
PRDCH22MH 400 EX xx xx xx 400W MH Electronic Pulse Start MH
Lumen Max Series, Octo Ballast Housing, Aluminum Reflector
ALOCT22MH 250 EX xx xx xx 250W MH Electronic Pulse Start MH
ALOCT22MH 320 EX xx xx xx 320W MH Electronic Pulse Start MH
ALOCT22MH 350EX xx xx xx 350W MH Electronic Pulse Start MH
ALOCT22MH 400 EX xx xx xx 400W MH Electronic Pulse Start MH
Lumen Max Series, Octo Ballast Housing, Prismatic Refractor
PROCT22MH 250 EX xx xx xx 250W MH Electronic Pulse Start MH
PROCT22MH 320 EX xx xx xx 320W MH Electronic Pulse Start MH
PROCT22MH 350 EX xx xx xx 350W MH Electronic Pulse Start MH
PROCT22MH 400 EX xx xx xx 400W MH Electronic Pulse Start MH
Tuesday, February 19, 2013 Page 20 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 52 (Retrofit Construction Only)Pulse Start Metal Halide Fixture with Electronic Ballast
Min Watts Saved (retro only): 64
Only New Metal Halide Pulse Start fixtures with Electronic Ballasts are eligible. Retrofit of existing metal halide fixture of less than 200 watts with new fixture is not eligible. Indoor and Outdoor fixtures are eligible.
Catalog Number
High Bay ‐ HIDDescription Efficiency
Lumen Max Series, Domed Ballast Housing, Prismatic Refractor
PRDDH22MH 250 EX xx xx xx 250W MH Electronic Pulse Start MH
PRDDH22MH 320 EX xx xx xx 320W MH Electronic Pulse Start MH
PRDDH22MH 350 EX xx xx xx 350W MH Electronic Pulse Start MH
PRDDH22MH 400 EX xx xx xx 400W MH Electronic Pulse Start MH
Catalog Number
Outdoor ‐ Area / FloodDescription Efficiency
Heavy Metal Lumen Max Series
HMI1616MH 200 xx xx 200W MH Electronic Pulse Start MH
HMI1616MH 250 xx xx 250W MH Electronic Pulse Start MH
HMI1616MH 320 xx xx 320W MH Electronic Pulse Start MH
HMI1616MH 350 xx xx 350W MH Electronic Pulse Start MH
Heavy Metal Lumen Max Series
HMI2424MH 320 xx xx 320W MH Electronic Pulse Start MH
HMI2424MH 320 xx xx 320W MH Electronic Pulse Start MH
HMI2424MH 350 xx xx 350W MH Electronic Pulse Start MH
HMI2424MH 400 xx xx 400W MH Electronic Pulse Start MH
HMI2424MH 450 xx xx 450W MH Electronic Pulse Start MH
Tuesday, February 19, 2013 Page 21 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 56High Intensity Fluorescent Fixtures (HIF) for High and Low Bay Applications (less than or equal to 195 W)
Min Watts Saved (retro only): 70
Minimum wattage is 96 Watts and Maximum wattage is 195 Watts. Minimum fixture efficiency must exceed 80%. Recommended mounting height > 16 feet above the floor. High Intensity Fluorescent fixtures incorporate a number of lamp technologies that include T‐8, T‐5, T‐5HO and compact fluorescent. Low power ballasts are not eligible.
Catalog Number
High Bay ‐ FluorescentDescription Efficiency
I‐Beam
IBC 354L 4' 3 Lamp 54W T5HO Program Start Ballast Single Switched MIRO Reflector, w/lamps
92%
IB 432 NDS 4' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched Narrow Distribution, MIRO Reflector, No Uplight
97%
Fluorescent High Bay
FGB164 4 32 T1X20 MVOLT 1/4 GEBH 16" x 4' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched MIRO Reflector
93%
MS5HB
MS5HB 3 54T5HO ND MVOLT GEB10PS 4' 3 Lamp 54W T5HO Program Start Ballast Multi Switched Normal Distribution, MIRO Reflector
99%
Catalog Number
Industrial ‐ OpenDescription Efficiency
L Series Standard
TL 2 32 MVOLT 1/4 BIHP 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 88%
AF Heavy Duty Turret
AFST 4 32 MVOLT 1/4 BIHP 4' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 80%
TAFST 2 32 MVOLT 1/4 BIHP 8' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 91%
EJ General Purpose
EJS 4 32 MVOLT 1/4 BIHP 4' 4 Lamp 32W HPT8 CEE1 Ballast Single Switched 89%
Tuesday, February 19, 2013 Page 22 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 57High Intensity Fluorescent Fixtures (HIF) for High and Low Bay Applications (greater than 195W)
Min Watts Saved (retro only): 95
Minimum wattage is greater than 195 Watts. Minimum fixture efficiency must exceed 80%. Recommended mounting height > 20 feet above the floor. High Intensity Fluorescent fixtures incorporate a number of lamp technologies that include T‐8, T‐5, T‐5HO and compact fluorescent. Low power ballasts are not eligible.
Catalog Number
High Bay ‐ FluorescentDescription Efficiency
I‐Beam
IB 632 NDS BINP 4' 6 Lamp 32W HPT8 CEE1 Ballast Multi Switched Narrow Distribution, MIRO Reflector
92%
IB 454 NDS 4' 4 Lamp 54W T5HO Program Start Ballast Narrow Distribution, MIRO Reflector
100%
IB 654 NDS 4' 6 Lamp 54W T5HO Program Start Ballast Multi Switched Narrow Distribution, MIRO Reflector
97%
Fluorescent High Bay
FGB24 6 32 N1X20 MVOLT 2/3 GEBH 2' x 4' 6 Lamp 32W HPT8 CEE1 Ballast Multi Switched MIRO Reflector 94%
FGB164 4 54T5HO N1X20 MVOLT 1/4 GEB10PS 16" x 4' 4 Lamp 54W T5HO Program Start Ballast Single Switched MIRO Reflector
87%
FGB24 6 54T5HO N1X20 MVOLT 1/41/2 GEB10PS 2' x 4' 6 Lamp 54W T5HO Program Start Ballast Multi Switched MIRO Reflector
Cold Storage Fluorescent High Bay
FFB24 6 32 N1X20 ACL MVOLT 1/41/2 GEBH 2' x 4' 6 Lamp 32W HPT8 CEE1 Ballast Multi Switched Normal Distribution, MIRO Reflector, Freezer
FFB164 4 54T5HO N1X20 ACL MVOLT 1/4 GEB10PS 16" x 4' 4 Lamp 54W T5HO Program Start Ballast Single Switched Normal Distribution, MIRO Reflector, Freezer
55%
FFB24 6 54T5HO N1X20 ACL MVOLT 1/41/2 GEB10PS 2' x 4' 6 Lamp 54W T5HO Program Start Ballast Multi Switched Normal Distribution, MIRO Reflector, Freezer
Spec‐Beam
FGB16 4 54T5HO N1X20 MVOLT 1/4 GEB10PS 4' 4 Lamp 54W T5HO Program Start Ballast Single Switched Medium Distribution, MIRO Reflector
FGB24 6 54T5HO N1X20 MVOLT 1/41/2 GEB10PS 4' 6 Lamp 54W T5HO Program Start Ballast Multi Switched Medium Distribution, MIRO Reflector
Catalog Number
Industrial ‐ OpenDescription Efficiency
AF Heavy Duty Turret
TAFST 3 32 MVOLT 2/3 BIHP 8' 6 Lamp 32W HPT8 CEE1 Ballast Multi Switched 80%
Tuesday, February 19, 2013 Page 23 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 57High Intensity Fluorescent Fixtures (HIF) for High and Low Bay Applications (greater than 195W)
Min Watts Saved (retro only): 95
Minimum wattage is greater than 195 Watts. Minimum fixture efficiency must exceed 80%. Recommended mounting height > 20 feet above the floor. High Intensity Fluorescent fixtures incorporate a number of lamp technologies that include T‐8, T‐5, T‐5HO and compact fluorescent. Low power ballasts are not eligible.
Catalog Number
Industrial ‐ OpenDescription Efficiency
AF Heavy Duty Turret
TAFST 4 32 MVOLT 2/4 BIHP 8' 8 Lamp 32W HPT8 CEE1 Ballast Multi Switched 80%
TAFPST 3 32 MVOLT 2/3 BIHP 8' 6 Lamp 32W HPT8 CEE1 Ballast Multi Switched
EJ General Purpose
TEJS 3 32 MVOLT 2/3 BIHP 8' 6 Lamp 32W HPT8 CEE1 Ballast Multi Switched 91%
TEJS 4 32 MVOLT 2/4 BIHP 8' 8 Lamp 32W HPT8 CEE1 Ballast Multi Switched 91%
Tuesday, February 19, 2013 Page 24 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 61Remote Mounted Occupancy Sensor
Min Watts Saved (retro only): 110
Comply with manufacturer’s coverage recommendations. Ceiling mounted control. No manual “ON” overrides
Catalog Number
SensorDescription Efficiency
Ceiling Mount
CM 9 Passive Infrared Ceiling Mount Sensor
CMR 9 Passive Infrared Ceiling Mount Sensor, Line Voltage
CM PDT 9 Dual Technology (PIR/Microphonics) Ceiling Mount Sensor
CMR PDT 9 Dual Technology (PIR/Microphonics) Ceiling Mount Sensor, Line Voltage
CM 10 Passive Infrared Extended Range Ceiling Mount Sensor
CMR 10 Passive Infrared Extended Range Ceiling Mount Sensor, Line Voltage
CM PDT 10 Dual Technology (PIR/Microphonics) Extended Range Ceiling Mount Sensor
CMR PDT 10 Dual Technology (PIR/Microphonics) Extended Range Ceiling Mount Sensor, Line Voltage
Passive Infrared Wide View Ceiling / Wall
WV 16 Passive Infrared Wide View Corner Mount Sensor
Dual Technology Wide View Ceiling / Wall
WV PDT 16 Dual Technology Wide View Corner Mount Sensor
WVR 16 Passive Infrared Wide View Corner Mount Sensor, Line Voltage
WVR PDT 16 Dual Technology Wide View Corner Mount Sensor, Line Voltage
Passive Infrared Hallway Wall
HW13 Passive Infrared Hallway Wall Mount Sensor
HWR13 Passive Infrared Hallway Wall Mount Sensor, Line Voltage
Tuesday, February 19, 2013 Page 25 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 62Daylight Dimming System(DDS‐FL)and/orOccupancy Controlled Step‐Dimming System
Min Watts Saved (retro only): 53 / Fixture
Daylight: Must have continuous dimming or adjust to a minimum of 4 levels. Typical lamping is either a 30 watt or 32 watt T8 lamp.Step‐Dimming: Ballast must be automatically controlled based on occupancy.Power consumption in low mode must not exceed 60%.
Catalog Number
SensorDescription Efficiency
Ceiling Mount
CM ADC Automatic Dimming Control Photocell, Ceiling Mount
CMR ADC Automatic Dimming Control Photocell, Ceiling Mount, Line Voltage
nCM ADC nLight Automatic Dimming Control Photocell, Ceiling Mount (0‐10 VDC)
Fixture & Ceiling Mount
CMRB ADC Automatic Dimming Control Photocell, Fixture Mount, Line Voltage
nLight Wall Pod Switch
nPOD DX nLight Wall Pod Switch, Dimming Control (For use with nPP16, requires 0‐10 VDC dimmable ballast)
Tuesday, February 19, 2013 Page 26 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 64Wall Mounted Occupancy Sensors
Min Watts Saved (retro only): 51
Occupancy Sensors must operate as Automatic On or Manual On and Off. Sensors are wall mounted devices only.Not eligible if installed in restrooms, locker rooms, stairwells or rooms of greater than 250 square feet
Catalog Number
SensorDescription Efficiency
Wall Mount
WSD VA Vacancy Switch
WSD Passive Infrared Wall Switch Decorator Sensor, Line Voltage
WSD 2P Passive Infrared Wall Switch Decorator Sensor, Line Voltage, 2‐Pole
WSD NL Passive Infrared Wall Switch Decorator Sensor, Line Voltage, Night Light
WSD P Passive Infrared Wall Switch Decorator Sensor, Line Voltage, Photocell
WSD PDT Dual Technology Wall Switch Decorator Sensor, Line Voltage
WSD PDT 2P Dual Technology Wall Switch Decorator Sensor, Line Voltage 2‐Pole
WSD PDT NL Dual Technology Wall Switch Decorator Sensor, Line Voltage, Night Light
WSD PDT P Dual Technology Wall Switch Decorator Sensor, Line Voltage, Photocell
Wall Mount
LWS Passive Infrared Large Area Wall Switch Sensor, Line Voltage
LWS PDT Dual Technology Large Area Wall Switch Sensor, Line Voltage
Wall Mount
LWS 2P Passive Infrared Large Area Wall Switch Sensor, Line Voltage, 2‐Pole
LWS PDT 2P Dual Technology Large Area Wall Switch Sensor, Line Voltage, 2‐Pole
Tuesday, February 19, 2013 Page 27 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 65Photocell Sensors or Hard‐Wired Astronomical Timer Controlled Lighting (For continuously operated lighting systems 24/7)
Min Watts Saved (retro only): 70
Photocell sensor or Hard‐Wired Astronomical Timer controlled lighting systems, or lighting circuit, that operate on 24 hours a day, 7 days a week (8,760 hours annually)
Catalog Number
SensorDescription Efficiency
Ceiling Mount
CMR‐PC Automatic On/Off Control Photocell, Ceiling Mount, Line Voltage
CM‐PC Automatic On/Off Control Photocell, Ceiling Mount
CMR‐PC‐ADC Automatic Dimming & Automatic On/Off Control Photocell, Ceiling Mount, Line Voltage
CM ADC Automatic Dimming Control Photocell, Ceiling Mount
CMR ADC Automatic Dimming Control Photocell, Ceiling Mount, Line Voltage
Fixture & Ceiling Mount
CMRB‐PC Automatic On/Off Control Photocell, Fixture Mount, Line Voltage
CMRB‐PC‐ADC Automatic Dimming & Automatic On/Off Control Photocell, Fixture Mount, Line Voltage
CMRB ADC Automatic Dimming Control Photocell, Fixture Mount, Line Voltage
Recessed Mount
RM‐PC‐ADC Automatic Dimming & Automatic On/Off Control Photocell, Recessed Mount
RMR‐ADC Automatic Dimming Photocell, Recessed Mount, Line Voltage
Tuesday, February 19, 2013 Page 28 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 68Integral High Bay Fixture Occupancy Control Systems
Min Watts Saved (retro only): 110 / Fixture
Fluorescent Ballasts or LED Drivers must be automatically controlled based on occupancy. Systems with manual “ON” or override switches are not eligible. Occupancy sensors are integral to (built into) or permanently attached to each fixture.
Catalog Number
SensorDescription Efficiency
Ceiling Mount
CMRB 50 Passive Infrared High Bay Aisle way Fixture Mount Sensor, Line Voltage
Fixture Mount
CMRB 6 Passive Infrared High Bay 360º Fixture Mount Sensor, Line Voltage
Tuesday, February 19, 2013 Page 29 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 70 (Retro only)Metal Halide Specialty Lighting Hard Wired Fixtures with Electronic Ballast
Min Watts Saved (retro only): 55
Metal Halide Specialty Fixtures may be track, recessed or surface mounted and used for high quality display‐type lighting. Must be approved by UL or similar agency.
Catalog Number
TrackDescription Efficiency
Tangent T6
ITH81 039 W FL24 1 Lamp Ceramic MH (CMH) Electronic Ballast Single Switched
ITH98 ‐ Wall Pro T6
ITH98 070 W PS 1 Lamp Ceramic MH (CMH) Electronic Ballast Single Switched
"Spectrak" Series
SAR30MH EX 1 Lamp Ceramic MH (CMH) Electronic Ballast Single Switched
Tuesday, February 19, 2013 Page 30 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 80ALED DownLight Fixtures‐ Hard Wired or GU‐ 24 base less than 25 watts & Screw Base LED Downlight Retrofit Kits.
Min Watts Saved (retro only): 14
Eligible LED Down Lights are required to be hardwired or GU‐24 basfixtures less than 25 watts and listed as a Commercial LED product bEnergy Star. Also Eligible ALL Screw Base LED Down Light RetrofiKits. (for more information see www.energystar.gov)
Catalog Number
DownlightDescription Efficiency
EVO Series
EVO XX/10 4AR MVOLT 4" LED 1000 Lumen Architectural Downlight Various Color Temeratures
EVO XX/10 6AR MVOLT 6" LED 1000 Lumen Architectural Downlight Various Color Temeratures
EVO XX/06 4AR MVOLT 4" LED 600 Lumen Architectural Downlight Various Color Temeratures
Reality Series
REAL6 D6MW ESL L7XRLED T24 6" LED 600 Lumen / 11.3 W, Various Color Temeratures
BL Series LED
5BL MW LED 120 6" LED 620 Lumen / 13.5W
4BL MW LED 120 4" LED 400 Lumen / 9W
5BL MW LED 120 5" LED 600 Lumen / 13W
Tuesday, February 19, 2013 Page 31 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 80BLED Downlight Fixtures‐ Hard Wired or GU‐ 24 base greater than or equal to 25 Watts
Min Watts Saved (retro only): 29
Eligible LED Downlights are required to be hardwired or GU‐24 base fixtures greater than or equal to 25 watts and listed as a Commercial LED product by Energy Star. (For more information see www.energystar.gov)
Catalog Number
DownlightDescription Efficiency
EVO Series
EVO XX/14 4AR MVOLT 4" LED 1400 Lumen Architectural Downlight Various Color Temeratures
EVO XX/18 4AR MVOLT 4" LED 1800 Lumen Architectural Downlight Various Color Temeratures
EVO XX/22 4AR MVOLT 4" LED 2200 Lumen Architectural Downlight Various Color Temeratures
EVO XX/14 6AR MVOLT 6" LED 1400 Lumen Architectural Downlight Various Color Temeratures
EVO XX/18 6AR MVOLT 6" LED 1800 Lumen Architectural Downlight Various Color Temeratures
EVO XX/22 6AR MVOLT 6" LED 2200 Lumen Architectural Downlight Various Color Temeratures
EVO XX/29 8AR MVOLT 8" LED 2900 Lumen Architectural Downlight Various Color Temeratures
EVO XX/29 6AR MVOLT 6" LED 2900 Lumen Architectural Downlight Various Color Temeratures
EVO XX/18 8AR MVOLT 8" LED 1800 Lumen Architectural Downlight Various Color Temeratures
EVO XX/22 8AR MVOLT 8" LED 2200 Lumen Architectural Downlight Various Color Temeratures
Tuesday, February 19, 2013 Page 32 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 82BLED Cooler, Freezer Case or Refrigerated Shelving Fixtures – 5’ & 6’ Fixture
Min Watts Saved (retro only): 23
Eligible LED Cooler and Freezer Case fixtures are required to be listed by Design Lights Consortium (for more information see www.designlights.org) Please specify quantity of end and/or center mount fixtures.
Catalog Number
RefrigerationDescription Efficiency
LED Vertical Refrigeration
FSV5‐REM LED Shiver Series Vertical Refrigeration
FSV5‐C LED Shiver Series Vertical Refrigeration
Tuesday, February 19, 2013 Page 33 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 83 A & BA: LED Low Bay Fixtures‐ Garage & Canopy fixtures to be installed in 8,760 hour Retrofit Kits no IncludedB: LED Low Bay Fixtures‐ Garage & Canopy fixtures to be installed in minimum of 4,380 hour Note: All Retrofit Kits Eligible.
Min Watts Saved (retro only): 60
A: Eligible LED Low Bay fixtures are required to be installed in 8,760 hour applications and be listed by Design Lights Consortium (for more information see www.designlights.org )
B: Eligible LED Low Bay fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org)
Catalog Number
GarageDescription Efficiency
Contour Series LED Area
KACM LED 1 49B350 LED With various distributions and color Temperatures
D‐Series LED Parking Garage
DSXSC LED LED With various distributions, lumen outputs and color Temperatures
DSXPG LED LED With various distributions, lumen outputs and color Temperatures
DSXPGT LED LED Tandem Mount, With various distributions, lumen outputs and color Temperatures
Ratio Series Architectural Garage
TLRPG 72LED 220mA 41K SYM XXX XXXXXXX XXXXXX XXX LED Symmetric Distribution, 4100K, 5300 Lumens
TLRPG 72LED 350mA 56K SYM XXX XXXXXXX XXXXXX XXX LED Symmetric Distribution, 5600K, 7483 Lumens
TLROC15 72LED 220mA 41K ASM XXX XXXXXXX XXXXXX XXX LED Asymmetric Distribution, 4100K, 5300 Lumens
Trace*Lite LEDLitelogic Series
TLED‐G‐DLC95‐MV‐XXX LED Inspire Series LED
PSL Series
PSL55 iDV1 LED
PSL55 iDV2 LED
PSL65 iDV1 LED
PSL65 iDV2 LED
PSL115 iDV1 LED
PSL115 iDV2 LED
PSL125 iDV1 LED
Tuesday, February 19, 2013 Page 34 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 83 A & BA: LED Low Bay Fixtures‐ Garage & Canopy fixtures to be installed in 8,760 hour Retrofit Kits no IncludedB: LED Low Bay Fixtures‐ Garage & Canopy fixtures to be installed in minimum of 4,380 hour Note: All Retrofit Kits Eligible.
Min Watts Saved (retro only): 60
A: Eligible LED Low Bay fixtures are required to be installed in 8,760 hour applications and be listed by Design Lights Consortium (for more information see www.designlights.org )
B: Eligible LED Low Bay fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org)
Catalog Number
GarageDescription Efficiency
PSL Series
PSL125 iDV2 LED
Canopy LED
CP60W LED LED
CP40W LED LED
TekDek Series
TD17‐xxx‐5S‐TP‐xx‐108L57K‐DV LED TEKDEK LED Series
TD17‐xxx‐5S‐TA‐xx‐50L50K‐DV LED TEKDEK LED Series
TD17‐xxx‐5S‐TP‐xx‐50L40K‐DV LED TEKDEK LED Series
TD17‐xxx‐5S‐TP‐xx‐108L40K‐DV LED TEKDEK LED Series
Baylume Series Garage
BYL CW CLR PND 24 LED This Industrial LED fixture is designed for use in warehouses, stockrooms, parking garages, gyms, hangars, tunnels and other applications that require widely distributed, glare free light. The fixture is ideal for 24X7 operation.
BYL CW CLR PND 48 LED This Industrial LED fixture is designed for use in warehouses, stockrooms, parking garages, gyms, hangars, tunnels and other applications that require widely distributed, glare free light. The fixture is ideal for 24X7 operation.
C2D "Curb 2 Door" Series
C2DLB NW R5 LED Curb 2 Door Series
Tuesday, February 19, 2013 Page 35 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 83 A & BA: LED Low Bay Fixtures‐ Garage & Canopy fixtures to be installed in 8,760 hour Retrofit Kits no IncludedB: LED Low Bay Fixtures‐ Garage & Canopy fixtures to be installed in minimum of 4,380 hour Note: All Retrofit Kits Eligible.
Min Watts Saved (retro only): 60
A: Eligible LED Low Bay fixtures are required to be installed in 8,760 hour applications and be listed by Design Lights Consortium (for more information see www.designlights.org )
B: Eligible LED Low Bay fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org)
Catalog Number
GarageDescription Efficiency
Structure Mounted parkVUE LED Area Light
PV PS1SHO 35 D5 DR NW UL1 3 1 EG LED 4500K, Type 5, 5655 Delivered Lumens
PV PS1SHO 53 D5 DR NW UL1 3 1 EG LED 4500K, Type 5, 5655 Delivered Lumens
Catalog Number
Industrial ‐ EnclosedDescription Efficiency
Archway Passage Series LED
VAP xxxLED 57 DLC LED With various outputs and color temperatures
Tuesday, February 19, 2013 Page 36 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 84LED Track Heads ‐ Hardwired less than or equal to 25 watts
Min Watts Saved (retro only): 30
LED track heads fixtures hardwired installations only, replacement lamps not eligible. Eligible fixtures are required to be less than or equal to 25 watts and listed by Design Lights Consortium (for more information see www.designlights.org)
Catalog Number
TrackDescription Efficiency
LED Track Heads
LX 2404 D3 L2 LED
LX 2024 D3 (M2, L2, M4, M6) LED
Tuesday, February 19, 2013 Page 37 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 85 (New & Retro Construction)LED Exterior wall Mount fixtures to be installed in a min of 4,380 hour applications. Architectural/Commercial Flood Light Fixtures to be installed in 4,380 hour applications
Min Watts Saved (retro only):
Eligible LED Exterior Wall Mount fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )Eligible LED Flood Lights Fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )Minimum 1000 Lumens
Catalog Number
Outdoor ‐ Area / FloodDescription Efficiency
DSXF LED Flood (New Construction Only)
DSXF2 LED LED With various distributions and color Temperatures
DSXF3 LED LED With various distributions and color Temperatures
DSXF1 LED LED With various distributions and color Temperatures
Forefront Flood (New Construction Only)
FRFT FL LED With various distributions, lumen outputs and color Temperatures
Catalog Number
Wall‐PackDescription Efficiency
OLW14 Series
OLW14 LED 1400 Lumen
OLAW LED Series Area / Wall
OLAW23 53K 120 PE BZ LED
OLW 23 & 31 Series LED Wall Pack
OLW 23 LED
OLW 31 LED
Aeris Architectural LED Wall Series
ASW1 LED 1 49B350 LED With various distributions and color Temperatures
D‐Series Wall Mount LED
DSXW1 LED LED With various distributions and color Temperatures
DSXW2 LED LED With various distributions and color Temperatures
Tuesday, February 19, 2013 Page 38 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 85 (New & Retro Construction)LED Exterior wall Mount fixtures to be installed in a min of 4,380 hour applications. Architectural/Commercial Flood Light Fixtures to be installed in 4,380 hour applications
Min Watts Saved (retro only):
Eligible LED Exterior Wall Mount fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )Eligible LED Flood Lights Fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )Minimum 1000 Lumens
Catalog Number
Wall‐PackDescription Efficiency
Countour LED Wall Pack
CSXW LED LED With various distributions and color Temperatures
LED Architectural Sconce
WST LED 1 10A700/40K SR4 LED
LED Wallpack
WPCS 40W LED LED
Millenium Finite 15"
FN15L LED With various distributions, lumen outputs and color Temperatures
Millenium Finite 9"
FN9L LED With various distributions, lumen outputs and color Temperatures
Forefront Wall
FRFT WP LED With various distributions, lumen outputs and color Temperatures
Relume Plus Seven LED Wall Pack
RPSWP5‐C‐NW‐UL‐X‐DB‐X‐X LED Decorative, 3500K, 6760 Delivered Lumens
Wall Pack LED
RPSWP5 LED With various distributions and color Temperatures
Tuesday, February 19, 2013 Page 39 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 86 (New Construction Only)LED Interior High Bay/Low Bay Fixtures
Min Watts Saved (retro only):
Eligible LED Interior High Bay/Low Bay fixtures recommended mounting height > 16 feet above the floor with minimum of 5,000 hour applications and are required to be listed by Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
High Bay ‐ LEDDescription Efficiency
Proteon LED High Bay Series
PTN12000LFDHD125 LED 12,000 Lumen, With various distributions and color Temperatures
PTN18000LFDHD125 LED 18,000 Lumen, With various distributions and color Temperatures
I‐BEAM® LED High Bay
IBL LED With various distributions, lumen outputs and color Temperatures
BayLight Series High Bay
IHB2 NW W MVOLT LED BayLight Series
Forefront High Bay
FRFT HB LED With various distributions, lumen outputs and color Temperatures
Highbay LED
SB400 A CW UL1 LED
Tuesday, February 19, 2013 Page 40 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 86 A & B (Retrofit Only)A: LED Interior High Bay/Low Bay Fixtures
B: LED Interior High Bay/Low Bay Fixture Note: All Retrofit Kits Eligible
Min Watts Saved (retro only): 95
A: Eligible LED Interior High Bay/Low Bay fixtures recommended mountingheight > 16 feet above the floor with minimum of 4,380 hourapplicationand are required to be listed by Design Lights Consortium (for more information see www.designlights.org )
B: Eligible fixtures and Retrofit Kits for LED Interior High Bay/Low Bay applications with mounting height > 16 feet above the floor are required tobe listed by Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
High Bay ‐ LEDDescription Efficiency
Proteon LED High Bay Series
PTN18000LFDHD125 LED 18,000 Lumen, With various distributions and color Temperatures
PTN12000LFDHD125 LED 12,000 Lumen, With various distributions and color Temperatures
I‐BEAM® LED High Bay
IBL LED With various distributions, lumen outputs and color Temperatures
LED Highbay
BLEXT 150W LED LED 161W / 14000 Lumens
BLEXT 100W LED LED 95W / 9094 Lumens
High Bay LED
HB 150W LED LED
HB 200W LED LED
BayLight Series High Bay
IHB2 NW W MVOLT LED BayLight Series
Forefront High Bay
FRFT HB LED With various distributions, lumen outputs and color Temperatures
Highbay LED
SB400 A CW UL1 LED
Tuesday, February 19, 2013 Page 41 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 87 (New & Retrofit Construction)LED Pole Mounted Parking, Roadway, or Decorative Fixtures
Min Watts Saved (retro only): 100
Eligible LED Pole Mounted Parking, Roadway, or Decorative fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
Cutoff ‐ LEDDescription Efficiency
Aeris LED Area and Roadway
AS1 LED Small LED With various distributions and color Temperatures
Omero LED Area and Roadway
MR1 LED 1 Small LED Replaces 70‐175W MH or HPS With various distributions and color Temperatures
MR2 LED 2 Large LED Replaces 175‐400W MH or HPS With various distributions and color Temperatures
Contour Series LED Area and Roadway
KAD LED 1 49B350 Medium LED With various distributions and color Temperatures
D‐Series LED Area
DSX2 LED Large LED Replaces 175‐400W MH or HPS With various distributions and color Temperatures
DSX1 LED Small LED Replaces 70‐175W MH or HPS With various distributions and color Temperatures
Contour CSX Series Area
CSX1 LED Small LED With various distributions and color Temperatures
CSX2 LED Large LED With various distributions and color Temperatures
Ratio Arm 4.0 Series
TLROA40 LED With various distributions and color Temperatures
TopDek LED Area & Roadway
TPD 23 LED With various distributions and color Temperatures
Tuesday, February 19, 2013 Page 42 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 87 (New & Retrofit Construction)LED Pole Mounted Parking, Roadway, or Decorative Fixtures
Min Watts Saved (retro only): 100
Eligible LED Pole Mounted Parking, Roadway, or Decorative fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
Cutoff ‐ LEDDescription Efficiency
LED Site Lighting
SHB CW CLR LED ShoeBox Series
Prolific Roadway Series
LSR1 CW R3 2B LED Roadway, Type 3, 50W, 5000k,
LSR2 CW R3 2B LED Roadway, Type 3, 75W, 5000k,
LSR3 CW R2 2B LED Roadway, Type 2, 100W, 5000k,
LSR3 CW R3 2B LED Roadway, Type 3, 100W, 5000k,
LSR4 CW R2 2B LED Roadway, Type 2, 150W, 5000k,
LSR4 CW R3 2B LED Roadway, Type 3, 150W, 5000k,
Prolific Roadway
DBR1 LED With various distributions and color Temperatures
DBR2 LED With various distributions and color Temperatures
Forefront Area
FRFT AR LED With various distributions, lumen outputs and color Temperatures
Roadmaster Series
RMS LED With various distributions, lumen outputs and color Temperatures
LED Area & Roadway
RPSA LED With various distributions and color Temperatures
Aerolume LED
AER‐II‐120LED‐NW LED Architectural LED Pole Mounted Cutoff Luminaire
Tuesday, February 19, 2013 Page 43 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 87 (New & Retrofit Construction)LED Pole Mounted Parking, Roadway, or Decorative Fixtures
Min Watts Saved (retro only): 100
Eligible LED Pole Mounted Parking, Roadway, or Decorative fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
Cutoff ‐ LEDDescription Efficiency
AER Mini
AERM II 64 LED NW LED Architectural LED Pole Mounted Cutoff Luminaire
Catalog Number
Pendant ‐ LEDDescription Efficiency
Hanover Series LED Pendant
EH16 GCF XXX 63LED 350mA LED With various distributions and color Temperatures
DSAP Series LED Decorative Roadway
DSAP25 LED With various distributions and color Temperatures
Catalog Number
Post Top ‐ LEDDescription Efficiency
Omero Post Top Series LED Area and Roadway
MRP LED 1 Small LED Replaces 70‐175W MH or HPS With various distributions and color Temperatures
TLRC10 18LED 700mA 41K GCF R5 LED Decorative, 4100K
Ratio LED Area & Roadway
TLPRO 152 LED With various distributions and color Temperatures
Tuesday, February 19, 2013 Page 44 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 87 (New & Retrofit Construction)LED Pole Mounted Parking, Roadway, or Decorative Fixtures
Min Watts Saved (retro only): 100
Eligible LED Pole Mounted Parking, Roadway, or Decorative fixtures are required to be installed in minimum of 4,380 hour applications (dusk to dawn) and be listed by Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
Post Top ‐ LEDDescription Efficiency
Forefront Pedestrian
FRFT PT LED With various distributions, lumen outputs and color Temperatures
Oxford Series
D‐O‐A‐ LED Oxford Series Decorative Acorn LED Pole Mounted Luminaire
Tuesday, February 19, 2013 Page 45 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 88, A&B (New & Retro)LED Linear Panels: Interior panels, 1X4, 2x2 and 2x4 Troffers
Retrofit Kits = 88B Only
Min Watts Saved (retro only): 38
Eligible LED Linear Panels: Interior 1X4, 2x2 and 2x4 Troffers are required to be Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
Surface CeilingDescription Efficiency
Linear Surface STL Series
STL448L 4' LED
Catalog Number
TrofferDescription Efficiency
ACLED Series
2ACL235LD38LP835 2' x 2' LED Recessed, Regressed Door, with various output and color Temperatures
2ACL448LD50LP835 2' x 4' LED Recessed, Regressed Door, with various output and color Temperatures
GTLED Contractor Select Series
GTLED2 31L D38 2' x 2' LED Dimmable Recessed, Flush Door
GTLED4 45L D50 2' x 4' LED Dimmable Recessed, Flush Door
TLED Series
2TL233LXXA19D38LP840 2' x 2' LED Recessed, Flush Door, with various output and color Temperatures
2TL446LXXA19D50LP835 2' x 4' LED Recessed, Flush Door, with various output and color Temperatures
Mino LED Series
MN9X33LMVOLTD41 2' x 2' LED Decorative Troffer, With various outputs and color temperatures
2200 Series Panel Fixture
2200‐DR‐S‐4000‐MV 2' x 2' LED
Tuesday, February 19, 2013 Page 46 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code 88, A&B (New & Retro)LED Linear Panels: Interior panels, 1X4, 2x2 and 2x4 Troffers
Retrofit Kits = 88B Only
Min Watts Saved (retro only): 38
Eligible LED Linear Panels: Interior 1X4, 2x2 and 2x4 Troffers are required to be Design Lights Consortium (for more information see www.designlights.org )
Catalog Number
TrofferDescription Efficiency
22 Series GEN 3 Panel Fixture
22‐G3‐35K‐40‐10V 2' x 2' LED
22‐G4 2' x 2' LED Genreation 4 in various color temperatures and wattages
Catalog Number
VolumetricDescription Efficiency
RTLED Series Recessed
RTL425LXXXD24 1' x 4' LED Recessed, with various color temperatures
2RTL2XXX33LXXXD38LP835 2' x 2' LED Recessed, Flush Door, with various output and color Temperatures
2RTL4XXX48LXXXD49LP835 2' x 4' LED Recessed, Flush Door, with various output and color Temperatures
VTLED Series
2VTL2X36LAPDXXXD36LP835 2' x 2' LED Recessed, with various output and color Temperatures
2VTL4X48LAPDXXXD47LP835 2' x 4' LED Recessed, with various output and color Temperatures
RTLED Series Surface
RTLX424LXXXD24 1' x 4' LED Surface Mounted, with various color temperatures
2RTLX232LXXXD38LP835 2' x 2' LED Surface Mounted, with various output and color Temperatures
2RTLX443LXXXD49LP835 2' x 4' LED Surface Mounted, with various output and color Temperatures
ALL Series
2ALL2 37L XXX D37 LP835 2' x 2' LED
2ALL2 37L XXX D37 LP840 2' x 2' LED
2ALL4 49L XXX D37 LP835 2' x 4' LED
2ALL4 49L XXX D37 LP840 2' x 4' LED
Tuesday, February 19, 2013 Page 47 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code Custom
Min Watts Saved (retro only): Custom
Catalog Number
GarageDescription Efficiency
Cavern Series LED
C4 40W LED LED
C4 60W LED LED
Catalog Number
LED CoveDescription Efficiency
Strip LED
ZL1 L48 2800L D75 LP840 LED LED Strip see spec sheet for many more variations that will meet the code for LED cove
Linear INT Series
O4LC 48 XX VOLT 120 LED Standard Brightness
05LC 48 XX VOLT XX LED High Power Brightness
Linear LED Cove
S301 LED
Catalog Number
Outdoor LED Retrofit KitDescription Efficiency
Retrofit Kit
RF11 0026 LED LED Retrofit Kits for Decorative Post Top Lighting
UA‐D‐D3‐WW‐UL‐2 LED LED Retrofit Kits for Decorative Post Top Lighting, Type 3, 3500K
Tuesday, February 19, 2013 Page 48 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
Utility Incentive Compliant Products
Code Custom
Min Watts Saved (retro only): Custom
Catalog Number
Outdoor LED Retrofit KitDescription Efficiency
Retrofit Kit
UA‐D‐D5‐CW‐UL‐2 LED LED Retrofit Kits for Decorative Post Top Lighting, Type 5, 5500K
UA‐D‐D5‐WW‐UL‐2 LED LED Retrofit Kits for Decorative Post Top Lighting, Type 5, 3500K
Tuesday, February 19, 2013 Page 49 of 50
Please note that this list is just a sampling of products. Many other products and variations can comply with the utility incentive program.Contact Boston Light Source for more information.
3 G L i g h t i n g premium recessed and decorative lighting * Acuity Brands the leading provider of lighting & controls *Ant ique S t re e t Lamps cast iron/aluminum poles, vintage post-top A x i s performance architectural recessed & linear A Y R E decorative sconces, pendant and flushmount B a r b i c a n custom fabrication B a r r o n emergency, commercial, industrial and LED
B a r t c o miniature fluorescent, display, cove, LED B o d i n e emergency fluorescent, LED & HID inverters B r o w n l e e energy star, fashionable & affordable C a n p l a s / C a n l e t non-metallic, vapor tight, marine C e l e s t i a l LED & fluorescent cove, low voltage, display C o n - T e c h track, recessed, glass pendants & low voltage C u s t o m M e t a l c r a f t local custom fabrication & restoration * D a r k t o L i g h t D T L energy conservation photo controls D e l r a y architectural, decorative industrial & downlights D e s i g n p l a n decorative, exterior, vandal resistant, LED E c o S e n s e performance white light LED & cove E E L P affordable, emergency, exterior, floods E l e c t r i x structural cove, strips, linear LED E l l i p t i p a r & T L Q high performance asymmetric lighting E v e r b r i t e graphic panels, MRI, LED F o c a l P o i n t high performance innovative designs F r a q t i r performance LED cove * G o t h a m downlighting, cylinders, pendants, LED H a m p s t e a d glass sconces, chandeliers, decorative H e a l t h c a r e medical, bed lights, surgical, MRI * H y d r e l performance landscape, in-ground, LED i G u z z i n i euro-style track, pendant, LED, exterior I n d u s t r i a l L i g h t i n g energy efficient, LED, retrofit, commercial I n t e n s e downlighting, track, exterior J L C * T e c h high power linear LED for suspended ceilings K e n a l l healthcare, institutional, high abuse, correctional K u r t V e r s e n downlighting, recessed, surface, atrium K W I n d u s t r i e s steel poles L a t e r n a D a n i c a decorative pendants, sconces, outdoor LBL art glass chandeliers, pendants, track
* L C & D digital lighting control systems, panels L e h i g h theatrical and architectural dimming controls Lighting Science Group LED lamps, area, roadway
L i t e c o n t r o l architectural linear direct/indirect fluorescent * L i t h o n i a commercial, industrial, emergency L S I track systems, museum, LED L u c a L i g h t LED library stack lighting specialists L u c e p l a n LED interior and exterior lighting L u m e n p u l s e LED specialty, cove, wall-grazing, floods L u n e r a LED recessed ceiling & linear pendant L U X d y n a m i c s fluorescent, large spaces, direct, direct/indirect * M a r k A r c h i t e c t u r a l architectural recessed fluorescent & LED M e t r o l i g h t HID electronic ballasts M o l t o L u c e LED, design, commercial, residential M O D A L i g h t LED, residential, commercial, marine
M o d u l a r L i g h t in g LED, residential, commercial, luminaires M y e r s P o w e r P r o duc t s emergency lighting & inverters N a t i o n a l C a t h o d e UL cold cathode, high lumen & curved N i n e 2 4 , I n c . emergency bypass relays P a r a m o u n t hazardous, wet location, clean room, transit * P e e r l e s s performance architectural linear fluorescent * = Acuity Brands Company
P h o s t e r down lighting, linear, retrofit, custom LED * R e L o c modular wiring solutions R e l u m e post top, garage, roadway R i g - A - L i t e specialty lighting for rugged applications * R O A M remote streetlight monitoring solutions R o b e r t s S t e p - L i t e low voltage, coves, miniature strips S c h r e d e r contemporary, architectural exterior, DOT, LED S e ’ l u x linear pendant, recessed extrusions, exterior * S e n s o r s w i t c h occupancy, daylighting controls S i r i u s European glass, curved track, LED S i s t e m a l u x euro-style recessed & pendant multi-lamp, decorative S p e c i a l t y recessed, accent, picture lights, cove S p e c t r u m commercial downlighting, cylinders, RLM, LED S t r o n g theatrical, spotlights, follow-spots S un V a l l e y cast aluminum, traditional exterior * S y n e r g y ( c o n t r o l s ) low voltage switching, controls * S u n o p t i c s Prismatic skylights T a m b i e n t furniture integrated task ambient systems * T e r s e n pedestrian scale architectural outdoor T r a x o n scalable, entertainment and architectural LED lighting U S A r c h i t e c t u r a l architectural exterior styles, LED U S P o l e steel & aluminum pole U S A I L i g h t i n g performance downlighting, LED V 2 L i g h t i n g custom instillations, modern design, unique fixtures V i s a architectural pendants, sconces, LED V o i g t extruded pendant, industrial W a l d m a n n precision task, contemporary fluorescent W E - E F euro-style performance exterior * W i n o n a custom, sconces, pendants, LED * W i n s c a p e exterior accent, landscape, in ground Z a n e e n architectural, decorative, outdoor, LED
6 4 c o m m e r c i a l w h a r f , B o s t o n , M a s s a c h u s e t t s 0 2 1 1 0 - 3 8 0 8
P H O N E : 6 1 7 . 78 8 . 2 4 0 0 F A X : 6 1 7 . 3 6 7 . 0 9 2 5
W E B : w w w. bo s t o n l i g h t s o u r c e . c o m
Represen ng manufacturers offering products with a
percep ble advantage for the coordina on of
ligh ng with architecture
B o s t o n L i g h t S o u r c e P e r s o n n e l ( p h o n e e x t . )
Principals: Ext: Outside Sales: Ext:
Paul L. Chabot 2443 Michael P. Chabot 2422
Ted H. Farnham 2433 William E. Cody 2461
Frederick W. Moynihan 2426 Brian T. DeConciliis 2435
Inside Sales: Brian W. Drew 2441
Lauren M. Cardea 2438 Robert A. Edwards 2434
Joseph P. Hurley 2430 Scott Ferriero 2427
Nicole Gaulin 2421 Joseph R. Frechette 2440
John F. Leary 2461 Daniel B. Hennessy 2429
Katherine E. Kane 2450 Joseph B. Kelly 2437
Suzanne M. Mendonca 2436 Harry Schofield 2411
Laura M. Moseley 2444 Tracy M. Shankle 2432
Emilie A. Pastore 2445 Jennifer M. Pinto 2442
Kati Pinder 2456 Mark J. Wholley 2452
Roberta B. Sicotte 2425
Lauren Scheer 2428
Cory L. Tripp 2423
To reach a Boston Light Source employee directly please dial 617.788. + their extension
Amy E. Walsh 2431
Email: To reach a Boston Light Source employee by email type their first initial followed by their last name @bostonlightsource.com. For example: [email protected]
L E D S p e c i a l i s t s C e l e s t i a l LED & fluorescent cove, low voltage, display E c o s e n s e performance white light LED & cove F r a q t i r asymmetric performance, cove I ndus t r i a l L igh t ing LED retrofit kits, commercial, industrial J L C * T e c h LED linear fixtures for suspended ceilings L i g h t in g S c i e n c e G r o u p LED lamps, area, roadway L u c a L i g h t LED stack lighting specialists L u c e p l a n LED interior and exterior L u m e n p u l s e LED specialty, cove, wall-grazing, floods L u n e r a LED recessed ceiling & linear pendant M O D A L i g h t i n g LED cabinets, lamps, display, ground, wall, ceiling M o l t a L u c e LED recessed, linear, downlight, custom P h o s t e r LED recessed, linear, puck, downlight, custom * R e n a i s s a n c e LED downlights R e l u m e post top, garage, roadway T r a x o n dynamic color changing & media fixtures Z a n e e n LED decorative, outdoor * W i n o n a linear, decorative, step and marker lightg
C o n t r o l s D i m m i n g , D a y l i g h t i n g , O c c u p a n c y A c u i t y B r a n d s C o n t r o l s L C & D digital lighting control systems, panels ROAM remote streetlight monitoring solutions S e n s o r S w i t c h occupancy & daylighting controls S y n e r g y low voltage switching controls
S u n o p t i c s prismatic skylights e : c u e state of the art control systems, panels L e h i g h theatrical and architectural dimming controls
R e t r o f i t & R e - l i g h t i n g f o r e n e r g y r e d u c t i o n I n d u s t r i a l L i g h t i n g commercial, retrofit, LED, industrial D e l r a y architectural, decorative industrial & downlights * L i t h o n i a efficient commercial & industrial, retrofit kits
E m e r g e n c y B o d i n e emergency fluorescent inverters B a r r o n emergency and EXIT LED signs E E L P emergency exits, battery units * L i t h o n i a emergency exits, battery units N i n e 2 4 , i n c . emergency override relays, BLTC K e n a l l exits M y e r s P o w e r P r o d u c t s emergency inverters including CMH
E n e r g y S t a r L i s t e d P r o d u c t M a n u f a c t u r e r s w w w . e n e r g y s t a r . g o v B r o w n l e e C o n - T e c h L i g h t i n g F o c a l P o i n t L i t h o n i a L i g h t i n g K e n a l l R e n a i s s a n c e U t i l i t y R e b a t e R e s o u r c e s P lease v i s i t www.bos ton l igh t source . com for a d i rec t l ink to current u t i l i t y incen t ive p rograms on our home page
I n d u c t i o n I n d u s t r i a l L i g h t i n g large selection of induction * L i t h o n i a available with induction technology S p e c t r u m wide variety of induction styles
O f f e r i n g Q u i c k S h i p * A n t i q u e S t r ee t L a m p s cast-iron/aluminum poles, vintage post-top e l l i p t i p a r high performance asymmetric lighting F o c a l P o i n t 5 & 10 day architectural designs * G o t h a m downlighting, cylinders, pendants, LED K e n a l l healthcare, institutional, high abuse, correctional * L C & D digital lighting control systems, panels L i t e c o n t r o l architectural linear direct/ indirect fluorescent: Litespeed * L i t h o n i a commercial, industrial, emergency L S I track systems, museum, LED * P e e r l e s s performance architectural linear fluorescent S e ’ l u x linear recessed extrusions: M series Quick Ship S u n V a l l e y cast aluminum traditional exterior T r a x o n LED color changing U S A r c h i t e c t u r a l steel poles, HID site lighting V i s a architectural pendants, sconces, LED (XPS program)
E x t e r i o r * A n t i q u e S t r e e t L a m p s cast-iron/aluminum vintage post-tops C a n p l a s / C a n l e t non-metallic – vapor tight, marine * D a r k t o L i g h t D T L energy conservation photo controls D e s i g n p l a n decorative, exterior, vandal resistant, LED e l l i p t i p a r high performance asymmetric lighting * H y d r e l performance landscape, in-ground, LED i G u z z i n i euro-style exterior, LED I n t e n s e stainless steel, surface & recessed exterior K W I n d u s t r i e s steel poles L a t e r n a D a n i c a Danish designs, decorative exterior * L i t h o n i a performance site & LED area L u m e n p u l s e LED specialty, cove, wall-grazing, floods N o r a l vintage post top, euro-style, wall sconces R e l u m e roadway, utility, department of transportation * R O A M remote streetlight monitoring solutions S c h r e d e r contemporary, architectural exterior, DOT, LED S e ’ l u x performance site, bollard, solar, landscape S i s t e m a l u x architectural exterior, floods Sun V a l l ey cast aluminum, traditional exterior * T e r s e n pedestrian scale architectural outdoor T r a x o n dynamic, color changing façade & media solutions U S A r c h i t e c t ur a l architectural exterior styles, LED V i s a architectural pendants, sconces, LED W E - E F euro-style performance exterior * W i n o n a custom, sconces, pendants, LED
DIRECTIONS:
FROM SOUTH/WEST: Take Rt. 93N into the new tunnel to Exit 23, Bear left at the top of the ramp. Take next left onto Surface Rd. Take left at second set of lights onto Atlantic Ave: Commercial Wharf is on the right next to Joe’s American Bar and Grille. FROM NORTH: Take Rt. 1 or 93 South to Exit 24A (Gov’t Center). Take left at the top ramp onto Surface Rd. Take left at second set of lights onto Atlantic Ave: Commercial Wharf is on the right next to Joe’s American Bar and Grille.
M e d i c a l & L a b o r a t o r y K e n a l l sealed, operating, exam, patient room H e a l t h c a r e medical, bedlilghts, surgical, MRI P a r a m o u n t hazardous, wet location, clean room, sealed L i t e c o n t r o l patient room, corridor, bed light K u r t V e r s e n high intensity focused exam light
February 13