BBU Main Processing & Transmission unit
WMPT/LMPT/UMPT inserted in slot 6/7 GTMU inserted in slot 6(both slots 5 and 6 occupied)
FAN
UPEU
UPEU
0 1 2 3
5 6 7
4
UMPT (Universal Main Processing & Transmission Board)
Support IPSec, GUL concurrent mode(SRAN8.0)
4E1/T1, 1FE/GE electrical port, 1FE/GE optical port
LMPT (LTE Main Processing & Transmission unit)
2FE/GE electrical port, 2FE/GE optical port , Support IPSec GTMU (GSM Transmission & Timing & Management Unit)
4E1/T1, 1FE electrical port, 1FE optical port
WMPT (WCDMA Main Processing & Transmission unit)
4E1/T1, 1FE electrical port, 1FE optical port
UMPT
FE/GE (Optical) CI
FE/GE (Electrical) E1/T1
G/ U/L light indicator
HUAWEI TECHNOLOGIES CO., LTD.
WBBPf inserted in slot 0/1/2/3/4/5
WBBPf for 3G
WBBPf4/LBBPd board
FAN
UPEU
UPEU
0 1 2 3
5 6 7
4
Interface ports: 6 (CPRI0 ~CPRI5) WBBPf4: 6 cells, DL/UL: 768CE/512CE
LBBPd inserted in slot 0/1/2/3/4/5
LBBPd for LTE
FAN
UPEU
UPEU
0 1 2 3
5 6 7
4
Interface ports: 6 (CPRI0 ~CPRI5) LBBPd3: 6x20M, 2T2R, DL/UL: 600M/300Mbps
Function:
Provides CPRI ports for communication with the RF modules (RRU)
Processes uplink and downlink baseband signals.
HUAWEI TECHNOLOGIES CO., LTD.
UCIU/UBRIb board
FAN
UPEU
UPEU
0 1 2 3
5 6 7
4
UCIU inserted in slot 4
UCIU: universal inter-connection infrastructure unit
M0 ~ M4
S0 GCK
UBRIb inserted in slot 0~3
UBRIb for 2G
BBU3900
FAN
UPEU
UPEU
5 6 7
4 0 1 2 3
Provides CPRI ports for communication with the RF modules (RRU)
HUAWEI TECHNOLOGIES CO., LTD.
WMPT /LMPT/GTMUb evolved.
F
A
N
UPEU
UPEU LBBP LMPT
F
A
N
UPEU
UMPT(GUL)
UPEU LBBP
LMPT
evolved
LMPT evolved: supports SingleOM and provides LTE signaling processing function.
HUAWEI TECHNOLOGIES CO., LTD.
BBU3900 Slot Assignment solution –reusing the existing BBU
Page 6
UBRIb+2G900
UBRIb+2G1800
WBBPf+3G900
LBBP+4G1800 UMPT (Existing L)
Reusing the existing 4G BBU ,existing
UMPT board, New
2G900&2G1800+3G900
Reusing the existing 4G BBU ,existing
LMPT board, New
2G900&2G1800+3G900
Existing
New
UBRIb+2G900
UBRIb+2G1800
WBBPf+3G900 UMPT
LBBP+4G1800 LMPT (Existing L)
New
HUAWEI TECHNOLOGIES CO., LTD.
BBU3900 Slot Assignment solution –New BBU
Page 7
UBRIb+2G900
UBRIb+2G1800
WBBf+3G900
UMPT (G+U)
UBRIb+2G900
UBRIb+2G1800
UMPT (G)
New 2G900&2G1800+3G900 with new BBU New 2G900+2G1800 with new BBU
HUAWEI TECHNOLOGIES CO., LTD.
BBU3900 Working in Multi-Mode with a Co-MPT
Page 8
Typical board configurations for a BBU3900 with a UMPT_GU board
HUAWEI TECHNOLOGIES CO., LTD. Page 9
New MiniShelter equipment layout (2.1M+AH1500&PC500D+Rack)
cable tray(1U) 1
spare Space(6U)
2
3
4
5
6
7
DCDU12B-3(0U) 8
DCDU12B-2(1U) 9
BBU2(2U) 10
11
spare Space(1U) 12
DCDU12B-1(1U) 13
BBU1(2U) 14
15
spare Space(2U) 16
17
Rectifier ETP48200(6U)
18
19
20
21
22
23
Battery1
24
25
26
27
28
29
30
31
Battery2
32
33
34
35
36
37
38
39
40
Item Equipment Compartment
Basic unit
specifications
Internal dimensions: 800 mm
x 800 mm x 1800 mm (31.50
in. x 31.50 in. x 70.87 in.)
Maximum external
dimensions: 905 mm x 1135
mm x 2110 mm (35.63 in. x
44.68 in. x 83.07 in.,
Typical
temperature
control mode
AH1500 (maximum power
consumption ≤ AC/ DC 640
W/200 W)
PC500D (maximum power
consumption ≤ DC 200 W)
Integration
Power system, baseband unit
(BBU), environment
monitoring unit, alternating
current distribution box
(ACDB), and automatic
transfer switch (ATS), and so
on
IP protection
level IP55
Weight ≤ 240 kg (529.20 lb)
HUAWEI TECHNOLOGIES CO., LTD.
New MiniShelter installation information
Page 10
Install as
single
cabinet Cabinet bottom
base view
HUAWEI TECHNOLOGIES CO., LTD. Page 11
New minishelter Rectifier-ETP48200
Rectifier module
(PSU)
Power Specifications
HUAWEI TECHNOLOGIES CO., LTD. Page 12
New minishelter AC power cable connection
Single phase case
HUAWEI TECHNOLOGIES CO., LTD. Page 13
New minishelter Battery cable connection
One string battery= 4 pcs
sell.
Battery capacity:100AH.
Weight: 124KG/string
HUAWEI TECHNOLOGIES CO., LTD. Page 14
New minishelter Power monitoring unit
Signal resource Alarm name Alarm type Power port
BBU port Cable color
Minishelter alarm list:
Mains failures NO ALM1
UPEU
EXT-ALM1
White/orange+, Orange-
DC low voltage NO ALM2 white/green+, Blue-
Rectifier failures NO ALM3 white/blue+, Green,
SPD failure NO ALM4 white/brown ,Brown- Load Breaker burn-out NO ALM5
UPEU
EXT-ALM0
White/orange+, Orange-
High temperature NO ALM6 white/green+, Blue-
Door open NO ALM7 white/blue+, Green,
Air-conditioner failures NO ALM8 white/brown ,Brown-
HUAWEI TECHNOLOGIES CO., LTD. Page 15
New minishelter Power alarm cable connection
HUAWEI TECHNOLOGIES CO., LTD. Page 16
New minishelter sensor cable connection
Door sensor Temperature &
humidity sensor
sensor
Battery Temperature
sensor
HUAWEI TECHNOLOGIES CO., LTD.
New minishelter Grounding cable connection
SLPU(1U)
EMUA (1U)
12V 150Ah
12V 150Ah
12V 150Ah
12V 150Ah
12V 150Ah
12V 150Ah
12V 150Ah
12V 150Ah
Power
System
(8U)
DCDU (1U)
BBU (2U)
SLPU (1U)
Space (15U)
Power
ETP48200
Door
DCDU
BBU
Rack Ground Point
Outdoor ground busbar
Rack
Ground
Indoor ground busbar Grounding cable
layout
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C
1
2 3 4 5
6
7
8
Internal Components
1 PSU 6 Battery Space
2 PMU 7 Baffle plate
3 Fan 8 Air Filter
4 Power distribution unit (PDU) 9
5
Door monitor 10
System Specifications
Dimensions (H x W
x D)
630 mm x 450 mm x 300 mm (The width of the protruding part of the door [60 mm]
is extracted from the cabinet depth.)
Weight ≤ 29 kg (excluding the weights of PSUs and storage batteries)
Rated capacity The maximum current is 60 A, in which case three 30 A PSUs are installed. 15 A
PSUs are also supported.
Installation Mounted on a wall, floor, or pole.
Cable routing Cables are routed out from the bottom.
Maintenance Maintained from the front, supporting module replacement.
Protection level IP55
Noise The operation noise is lower than 55 dB, complying with YD/T 1058
Heat dissipation Natural-ventilation unit
Battery (optional) Built in with a 48 V 20 Ah/40 Ah battery string.
Electrical Specifications
AC input system Single-phase (L-N or L1-L2. The live wire and neutral wire can be reversely
connected.)
Input voltage 85=300VAC (The rated input voltage is 220 V AC.)
Input frequency 45–65 Hz (The default input frequency is 50 Hz or 60 Hz.)
Output voltage 43.2–58 V DC (The default output voltage is 53.5 V DC.)
AC surge protection
level
Level C (20/40 kA, 8/20 µs). Level B (30/60 kA, 8/20 µs) can be customized.
DC surge protection Differential mode: 10 kA
Common mode: 20 kA
Surge protection for
signal ports
Differential mode: 3 kA
Common mode: 5 kA
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
Item Specifications
Rated capacity 40 Ah
Rated voltage 48 V DC
Operating temperature –20°C to +55°C
Dimensions (H x W x D) 133 mm x 385 mm x 350
mm
Weight ≤ 27 kg
Maximum discharge power 1500 W (the backup time is
1 hour)
Maximum charge current 8 A
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
Item TP4860C-D06A1
AC input circuit
breaker
One 2-pole 32 A
circuit breaker
Maintenance socket 1
AC surge protection
device (SPD) Class C, 4-pole
DC SPD 1
DC output circuit
breaker
Three 1-pole 32A
circuit breakers
Battery circuit
breaker
One 1-pole 63 A
circuit breaker
HUAWEI TECHNOLOGIES CO., LTD.
DCDU12B View
Page 24
HUAWEI TECHNOLOGIES CO., LTD.
APM30 DC(TMC11H ,Ver.D)
Exterior of the APM30H(TMC11H)
Page 25
Power Specifications Supplied with -48 V DC power.
Configured with a DCDU-12B, which distributes power into RRUs and the
BBU, fan assembly, and transmission equipment in the TMC11H
. Parameter Specifications
Characteris
tics of DC
input
Input voltage range -38.4 V DC to -57 V DC
Typical input voltage -48 V DC
Maximum input current •The maximum input current depends on the application
scenario. In a distributed base station: 160 A
•In a separated macro base station: 30 A (When the TMC11H is
configured together with the APM30H, the APM30H supplies
power to the TMC11H.)
Input mode -48 V DC power input, supporting the one-hole M6 OT terminal
Characteris
tics of DC
output
DC distribution Ten -48 V DC outputs: LOAD0 to LOAD9, used to supply power
to the customer equipment
Typical output voltage -48 V DC
Protection Providing overcurrent protection and short-circuit protection for
the DC power
HUAWEI TECHNOLOGIES CO., LTD.
APM30H DC (TMC11H ,Ver.D) Exterior of the APM30H
Page 26
Parameter Specifications Remarks
Dimensions (H x
W x D)
Cabinet (without the
base): 700 mm x 600 mm
x 480 mm (27.56 in. x
23.62 in. x 18.90 in.)
The TMC11H and APM30H have the same
exterior and base.
Base: 200 mm x 600 mm
x 434 mm (7.87 in. x
23.62 in. x 17.09 in.)
Space for the
customer
equipment (H x W
x D)
11 U x 19 in. x 380 mm The depth includes 100 mm (3.94 in.) in front of
the columns and 280 mm (11.02 in.) between the
columns and the rear of the cabinet.
Cabinet weight ≤ 47 kg (103.64 lb) Total weight of the equipment
Including the cabinet frame, outer air
circulation assembly (heat dissipation core and
outer air circulation fan), inner air circulation
fan assembly, DCDU, and cables
Excluding the customer transmission
equipment
Method of
installation
It can be installed on the
ground, pole, or wall. It
can also be installed on
an RFC, IBBS200D, or
IBBS200T in stack mode.
In stack mode, the TMC11H must be installed on
the top of the RFC, IBBS200D, or IBBS200T
HUAWEI TECHNOLOGIES CO., LTD.
APM30 H( TMC11H VerD detail component)
Page 27
No. Component Remarks
1 Outer air
circulation
assembly
The assembly is installed on the front door of the cabinet, dissipating heat from the cabinet.
2 Junction box
The junction box converts one AC input to four AC outputs and is used in the scenario where a service outlet unit (SOU) and
multiple heating films or heaters are configured.
3 FAN 02D The fan assembly is configured with fans and central monitoring unit type EA (CMUEA), dissipating heat from the cabinet.
4 SLPU
To provide protection for trunk signals,
To provide protection for monitoring signals.
5 Door sensor The door status sensor monitors the status (open or closed) of the cabinet door.
6 ELU The electronic label unit (ELU) reports the cabinet type automatically to facilitate troubleshooting.
7 DCDU-12B or
DCDU-12C
The direct current distribution unit-12B (DCDU-12B) or direct current distribution unit-12C (DCDU-12C) in the TMC11H
distributes DC power to all the components in the TMC11H. A DCDU-12B or DCDU-12C is 1 U high. The DCDU varies with the
installation scenarios.
8 BBU3900 A maximum of two BBU3900s can be configured in a TMC11H.
9 EMUA The environment monitoring unit type A (EMUA) monitors environment of the equipment.
10 Filler module
A filler module is a plastic component with a height of 1 U in the cabinet, preventing the heat reflux in the empty space below the
BBU.
11 AC heater
The AC heater ensures that components in the cabinet work within the acceptable temperature range when the surrounding
temperature is low. It can be preferentially installed in the 1 U space at the bottom of the cabinet.
HUAWEI TECHNOLOGIES CO., LTD.
APM30 AC (Ver.D)
Exterior of the APM30H AC
Page 28
Power Specifications
Item Specifications
Characteristics of AC input
Typical input voltage
200 V AC to 240 V AC (220 V AC single-phase)
200/346 V AC to 240/415 V AC (220/380 V AC three-phase)
100/200 V AC to 120/240 V AC (110 V AC dual-live-wire)
120/208 V AC to 127/220 V AC (120 V AC dual-live-wire)
Rated input current
53 A (220 V AC single-phase)
23 A (220/380 V AC three-phase)
55 A (110 V AC dual-live-wire)
52 A (120 V AC dual-live-wire)
Characteristics of DC output
Output voltage range -43.2 V DC to -57 V DC
Output current range 0 A to 150 A
Typical output voltage -53.5 V DC
DC outputs
The number of DC outputs depends on the application scenario.
A distributed base station uses 17 DC outputs
A separated base station uses 12 DC outputs.
DC output power ≤ 9000 W (When there is no backup PSU, the maximum power of each PSU is
3000 W.)
HUAWEI TECHNOLOGIES CO., LTD.
APM30H AC (Ver.D) Exterior of the APM30H
Page 29
Item Specification Remarks
Weight
≤ 68 kg
Total weight of the equipment
Including the cabinet frame, inner air
circulation fan box, outer air circulation
fan box, core of the heat exchanger,
embedded power subrack unit (EPU),
and cables
Excluding the baseband processing unit
(BBU), customer equipment, power
monitoring unit (PMU), and PSUs
≤ 87 kg
Weight of the cabinet in full configuration
Including the cabinet, one PMU, three
PSUs, and one BBU
Excluding customer equipment
Cabinet dimensions (H x W x D) 700 mm x 600 mm x 480 mm The base is not included.
Base dimensions (H x W x D) 200 mm x 600 mm x 434 mm -
Customer equipment dimensions (H
x W x D) 7 U x 19 in. x 380 mm
The depth consists of the rear (280 mm)
and front (100 mm) of the installation
plane for subrack mounting ears.
Space for cabling and maintenance
in front of the cabinet 70 mm -
Installation option
The APM30H can be installed
on a floor, wall, or pole. It can
also be stacked with the radio
frequency cabinet (RFC),
IBBS200D, or IBBS200T.
The APM30H must
HUAWEI TECHNOLOGIES CO., LTD.
APM30H AC-APM30H+Battery(Used for a Distributed Base Station)
Page 30
Figure 1 Scenario where the APM30H is stacked with a battery cabinet and is used for a distributed base station
When the APM30H is used for a distributed
base station:
The APM30H provides 7 U-high space for
installing the BBU and transmission
equipment. The embedded power supply
system provides -48 V DC power to the
distributed base station and transmission
equipment and charges battery groups in a
battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the distributed base station and
transmission equipment
HUAWEI TECHNOLOGIES CO., LTD.
APM30H AC-BTS3900A(Used for an Outdoor Macro Base Station)
Page 31
Figure 2 Scenario where the APM30H is used for an outdoor macro base station
When the APM30H is used for an outdoor
macro base station:
The APM30H provides 7 U-high space for
installing the baseband processing unit (BBU)
and transmission equipment. The embedded
power supply system provides -48 V DC power
to the BBU, radio frequency unit (RFU), and
transmission equipment and charges battery
groups in a battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the BBU, RFU, and transmission
equipment.
The APM30H provides alarm reporting functions
for radio frequency cabinet (RFC) fans, door
status sensor, direct current distribution unit
(DCDU), and battery cabinet.
HUAWEI TECHNOLOGIES CO., LTD.
OMB (Ver.C) The OMB (Ver.C) is designed for SRAN8.0 and later versions
Base stations supported by the OMB (Ver.C):
DBS3900
The OMB (Ver.C) supports all current RRU versions.
Page 32
DBS3900 (AC) DBS3900 (DC)
HUAWEI TECHNOLOGIES CO., LTD.
OMB (Ver.CMPE Specifications ) in AC Scenarios
Page 33
Dimensions (H x W x D) 600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)
Temperature Range -33oC to 50oC (-27.4oF to 131oF)
Weight 30 kg or 66.15 lb (without a BBU)
Protection Class IP55
Admission Requirement CE
Power Supply Mode 110 V AC dual-live-wire or 220 V AC single-phase
Temperature Control Subsystem Heat exchanger
Power Supply Subsystem ETP48100-A1
Embedded power system, with a maximum power capacity of 100 A
Output DC power distribution: two 100 A outputs
Power Distribution Subsystem Ten power outputs of 30 A
Surge Protection
AC power port: rated 20 kA; maximum 40 kA; 8/20 us waveform
DC power output port: 10 kA in differential mode and 20 kA in
common mode; 8/20 us waveform
Cable Outlet Position Bottom of the cabinet
HUAWEI TECHNOLOGIES CO., LTD.
Structure and Components of the OMB in AC Scenarios
Page 34
1 2 3 4
5 6
7 8
9
10
No. Configuration Description
1 Mandatory Electronic label unit (ELU)
2 Mandatory FAU01D-01 (inner air circulation fan assembly)
3 Mandatory Door status sensor
4 Mandatory SPD40/S (AC surge protector)
5 Mandatory HEUB (control unit for heat
exchanging)
6 Mandatory PMU11A (power management unit)
7 Mandatory PSU (R4850G2 rectifier)
8 Mandatory PDU10D-01 (DC power distribution
unit)
9 Mandatory ETP48100-A1 (embedded power system)
10 Mandatory FAU01D-01 (outer air circulation
fan assembly)
HUAWEI TECHNOLOGIES CO., LTD. Page 35
OMB (Ver.C) MPE Specifications in DC Scenarios
Dimensions (H x W x D) 600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)
Temperature Range -33oC to 50oC (-27.4oF to 131oF)
Weight 21 kg or 46.31 lb (without a BBU)
Protection Class IP55
Admission Certification CE
Power Supply Mode -48 V DC
Temperature Control
Subsystem Heat exchanger
Power Distribution
Subsystem Ten power outputs of 30 A
Surge Protection DC power output port: 10 kA in differential mode and 20 kA in common mode;
8/20 us waveform
Cable Outlet Position Bottom of the cabinet
HUAWEI TECHNOLOGIES CO., LTD.
Structure and Components of the OMB in DC Scenarios
Page 36
1 2 3
4
5 6
7
No. Configuration Description
1 Mandatory ELU
2 Mandatory FAU01D-01 (inner air circulation fan
assembly)
3 Mandatory Door status sensor
4 Mandatory HEUB (control unit for heat
exchanging)
5 / 1 U space for customer equipment
6 Mandatory PDU10D-01 (DC power distribution
unit)
7 Mandatory FAU01D-01 (outer air circulation fan
assembly)
HUAWEI TECHNOLOGIES CO., LTD.
Engineering Interface of the OMB (Ver.C)
Page 37
Engineering Interface of the OMB (Ver.C) in AC Scenarios
1. The AC input power cables are single-
core cables, each with dual insulation
layers.
2. If more PSUs are added, the customer
engineering interface must be changed.
Therefore, ensure that the circuit
breakers and power cables meet the
requirements before the PSUs are
added.
Engineering Interface of the OMB (Ver.C) in DC Scenarios
AC Input Mode Number of PSUs Requirements for AC Circuit
Breakers
Input Power Cable Remarks
220 V AC single-phase 2 32 A, 1 P 4 mm2 The circuit breaker is connected to the L phase.
110 V AC dual-live-wire 2 32 A, 2 P 4 mm2
220 V AC single-phase 1 20A, 1 P 4 mm2 The circuit breaker is connected to the L phase.
110 V AC dual-live-wire 1 20 A, 2 P 4 mm2
Related Unit
Configuration
RRU Power Number of
RRUs
Requirements for
DC Circuit Breakers
Input Power
Cable
Distance Between the OMB (Ver.C)
and External Power Equipment
BBU: 450
W
RRUs of
the same
model
≤ 300 W 1~3 50A, 1 P 16 mm2 5 m
≤ 300 W 4~6 80 A, 1 P 16 mm2 5 m
≤ 400 W 1~3 63 A, 1 P 16 mm2 5 m
≤ 400 W 4~6 100 A, 1 P 16 mm2 5 m
≤ 560 W 1~3 80 A, 1 P 16 mm2 5 m
≤ 560 W 4~6 125 A, 1 P 25 mm2 5 m
2x60 A, 2 P 2x16 mm2 5 m
BBU: 450
W
RRUs of
different
models
≤ 300 W 3
80 A, 1 P 16 mm2 5 m ≤ 300 W
≤ 400 W
3
≤ 300 W 3
100 A, 1 P 16 mm2 5 m ≥400W
≤ 560 W
3
≤ 400 W 3 100 A, 1 P 16 mm2 5 m
HUAWEI TECHNOLOGIES CO., LTD. Page 38
Application Scenarios of the OMB (Ver.C)
Rooftop Outdoor-S2 Greenfield Outdoor-
S4
Urban Street-S5 Indoor-S6 Rural Road-S7
Installing on
the pole of
rooftop
Installing on
the wall of
rooftop
Installing on
the bottom of
the tower
Installing on
the Lamp pole
of the street
side
Installing on
the carport
Installing on
the wall of
veranda
Installing on
the pole of
the road side
HUAWEI TECHNOLOGIES CO., LTD.
Stacking the OMB (Ver.C) onto the Top of the BTS3900A
Page 39
Adapting piece I
Adapting piece IV
Item Quantity Description
Adapting piece I 2 Secured to the lifting eyes on the
top of the BTS3900A
Adapting piece IV 2 Used to secure adapting piece I to
the rear of the OMB
The solution of stacking the OMB (Ver.C) onto the BTS3900A is
carried out only as a non-standard solution.
HUAWEI TECHNOLOGIES CO., LTD.
The changes from OMB Ver.A to OMB Ver.C
Page 40
OMB Ver.A OMB Ver.C
New PDU
New ELU
unit
AC SPD SPD40/S
ETP48100-A1 EPS30-4815AF
HUAWEI TECHNOLOGIES CO., LTD. Page 41
DBS3900 (-48 V): Outdoor BBU and Outdoor RRUs (Ver.C)
A DC OMB Ver.C supports a maximum of six 2x60 W RRUs.
The heat consumption of a DC OMB Ver.C cabinet (the total heat consumption of the built-in
BBC and TC) is lower than or equal to 450 W (with the urban-level noise and in ambient
temperature of 50ºC.)
The DC OMB Ver.C supports -48 V power input.
The protection level of the DC OMB Ver.C is IP55.
The DC input/output port surge protection specification is 10KA/20KA.
The DC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both
on the top of and beside a BTS3900A. In this case, an attachment plate is required and no
footprint is required.
The DC OMB Ver.C can operate in a temperature range of -33ºC to +50ºC.
For the power supply requirements, see the Power Supply Interface Requirements for Wireless
Base Stations.
Back
Solution: OMB(-48 V) + 6 x RRU (optional)
DC power cable
ground cable
feeder
Optical fiber
ACDB Power interface
Customer side
OMB V.C
RR
U
HUAWEI TECHNOLOGIES CO., LTD. Page 42
DBS3900 (AC): Outdoor BBU and Outdoor RRUs (Ver.C)
An AC OMB Ver.C supports a maximum of six 2x60 W RRUs (power backup is not supported when the
load power exceeds 3000 W).
An AC OMB Ver.C has a built-in ETP48100 power supply system and two PSUs, with a maximum output
power of 6000 W (3000 W for a single PSU.)
The AC OMB Ver.C supports 220 V single-phase and 110 V dual-live-wire AC input.
The heat consumption of an AC OMB Ver.C cabinet is lower than or equal to 450 W (the heat consumption
of the BBU is lower than or equal to 250 W) with the urban-level noise and in ambient temperature of
50ºC.
The protection level of the AC OMB Ver.C is IP55.
The AC OMB Ver.C cannot be installed on a tower and can not be installed at a position higher than 10 m.
The AC OMB Ver.C supports remote RRU.
The AC OMB Ver.C supports a surge protection of a maximum of 40 KA at the AC power input port and 10
KA/20 KA at the DC power output port.
The AC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both on the top of
and beside a BTS3900A. In this case, an attachment plate is required and no footprint is required.
The DC OMB Ver.C can operate in a temperature ranging from of -33ºC and +50ºC.
Power backup is not supported.
For the power supply requirements, see the Power Supply Interface Requirements for Wireless Base
Stations.
Back
Solution: OMB (AC) + 6 x RRU (optional)
AC power cable
ground cable
feeder
DC power cable
optical fiber
ACDB Power interface
Customer side
OMB V.C
RRU
HUAWEI TECHNOLOGIES CO., LTD.
DBS Senario
Page 43
Existing
transmission
equipment
CPRI optical
HUAWEI TECHNOLOGIES CO., LTD.
DBS Structure
Page 44
HUAWEI TECHNOLOGIES CO., LTD. Page 45
Appearance of Figure
Branch of Cable
Connected to Equipment
CPRI Cable
HUAWEI TECHNOLOGIES CO., LTD. Page 46
CPRI Cable Single mode/Multi-mode Length Length of branch Be used Connect to Connector Cores
Multi-mode 5m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 10m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 20m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 30m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 40m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 50m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 60m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 80m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 100m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 120m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 150m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Single mode 5m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2FC/UPC 2
Single mode 20m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2SC/UPC 2
Single mode 20m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2SC/UPC 2
Single mode 10m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2LC/UPC 2
Single mode 20m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2LC/UPC 2
Single mode 5m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 20m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 30m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 50m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2SC/UPC 2
Single mode 10m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2LC/UPC 2
Single mode 10m 0.03m/0.03m CPRI RRU-RRU DLC/UPC-DLC/UPC 2
Multi-mode 10m 0.03m/0.03m CPRI RRU-RRU DLC/UPC-DLC/UPC 2
HUAWEI TECHNOLOGIES CO., LTD.
Existing Transmission SmartAXOT928G-D
Page 47
HUAWEI TECHNOLOGIES CO., LTD.
RRU3936 Ports on the RRU panels
Page 48
RRU dimensions
RTN(+) / NEG(-) -- Power supply socket
CPRI0/1-- Optical/electrical port 0, connected to the BBU
(2) ANT_TX/RXA TX/RX port A-- supporting RET signal transmission
ANT_RXB RX-- port B
HUAWEI TECHNOLOGIES CO., LTD.
RRU installation on pole
Two RRUs installed on a pole One RRUs installed on a pole Three RRUs installed on a pole If on ground
HUAWEI TECHNOLOGIES CO., LTD.
RRU installation on wall
RRU installed on the wall
HUAWEI TECHNOLOGIES CO., LTD.
RRU installation inside shelter
Installing RRUs on the lower level-1
Indoor IFS06
Installing RRUs on the lower level-2
Indoor IFS06
HUAWEI TECHNOLOGIES CO., LTD.
RRU 3936 DC RRU3936 Multi-mode 900MHz EGSM RRU3826
Page 52
Item Specifications
Input power
–48 V DC; voltage range: –36 V DC to –57 V DC
The RRU3936 supports AC applications after being configured with an AC/DC power module. For details, see the AC/DC Power Module User Guide.
Port Connector Quantity Function
RF port DIN 2 Connects to an antenna
Common public
radio interface
(CPRI) port
DLC 2 Connects to the baseband unit
(BBU3900)
Power supply socket Easy power
receptacle (pressfit
type)
1 Receives –48 V DC power
RET port DB9 1 Connects to a remote control
unit (RCU)
Item Specifications
Dimensions (H x
W x D)
400 mm x 240 mm x 160 mm (with the
housing)
400 mm x 220 mm x 140 mm (without
the housing)
Weight 15 kg (with the housing)
13.5 kg (without the housing)
HUAWEI TECHNOLOGIES CO., LTD.
Jumper Connector Type
Page 53
Types of connectors for jumpers
HUAWEI TECHNOLOGIES CO., LTD.
Jumper Connector Type
Page 54
Difference between the male connector and female connector
HUAWEI TECHNOLOGIES CO., LTD.
Jumper Connector Type
Page 55
Difference between the DIN connector and N connector
HUAWEI TECHNOLOGIES CO., LTD.
Optical Connector and Flange
Page 56
SC optical connector and flange
HUAWEI TECHNOLOGIES CO., LTD.
Optical Connector and Flange
Page 57
FC optical connector and flange
LC optical connector and flange