product presentation sr and srm 07062018 product... · 2018-11-30 · title: product presentation...
TRANSCRIPT
MARRE
Safety Relays and Safety Relay Modules......
........in a short brief
MARRE
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected] Product presentation SRM
MARRE Safety Relays Modules
Business area
Railway automationBusiness area
Safety related Signal interfacing
Interface module for safety related signalsto manage Turbofan engine Test Benches
Safety Speed limiter signal module for elevator control systems
Module for vital safety related Signallingin Power Plant control systems
AVAILABILITY.SAFERELIABILITY
Safety relay modules for safe signal interfacingin the scope- train control- interlockings- Railroad crossing technology
Safety relay modules for safe control functionsfor rail vehicles
Subsystems for rail vehicles
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected] Product presentation SRM
Page 02
MARRE Safety Relays
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
A combination of normally open contactsand normally closed contacts designed so that they cannot simultaneously be inthe closed position
When a normally open contact is closed, none of the normally closed contactsmay be closed.
When a normally closed contact is closed,none of the normally open contactsmay be closed.
Mechanically linked contacts (moving part)
Normally open contact*
*Contact position shows relay drive de-energized
Standard contact material for railway applicationSilver Tin Oxide + 5µm gold plated
Normally close contact*
Normally close contact*
Definition
Relay with forcibly guided contacts
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 03
Product presentation SRM
MARRE
H-464.4 series
H-466.3 series
Safety Relays
H-series
H-464.3 seriesH-464.3 series
H-464.3 series
H-470.1 series
H-463 series
H-RBS series
H-468 series
H-469 series
H-480 series
H-466.1 series
H-472 series
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 04
Product presentation SRM
MARRE Safety Relays
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 05
H-462.1 series*H-462.2 series*
220, 310 10.0A10.0A
10.0A
10.0A10.0A
6.0A
6.0A
6.0A
8.0A
X XX X
X X
X XX X
X
X
X
X
220, 310
110
430, 520
420
110, 002
330, 420
440, 530, 260, 620640, 730, 370, 640, 820
H-463 series*
H-464.3 series*H-464.4 series*
H-469 series**
H-472 series**
H-480 series**
H-RBS series**
Selector Relay series Contact set (NO - NC - CO)
Coil voltages DC 5 6 12 24 48 60 72 110 220
Standard contact material* AgSnO + 5µm Au
Standard contact material** AgSnO + 2µm Au
*other contact material on request
Max. switching current
Drivenon-latching latching
RT III (wash tight)
RT II (flux proof)
Test voltage 2000/5000/4000V
Test voltage 2500V
Test voltage 2000V
for Railway applications
Sele
cto
r-D
esc
rip
tio
n
Relays with forcibly guided (mechanically linked) contacts H-Series
Product presentation SRM
MARRE Safety Relays
SR-SIP/510 series
SR-SIF/212 series
SR-SIF/420 series
SR-SIS/310 series
SR-SIF/310 seriesSR-SIS/210 series
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
1) Relay Approval
Page 07
Product presentation SRM
E-series
MARRE Safety Relays
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 06
6.0A
6.0A
8.0A
6.0/12.0A
6.0/16.0A
X
X
X
X
X
110
210
220, 310
220, 310 Power
510, 420 Power
SR-SIS 2 series*
SR-SIS 3 series*
SR-SIF 4 series*
SR-SIR 4 P series**
SR-SIP 6 series**
Selector Relay series Contact set (NO - NC - CO) Max. switching current
Drivenon-latching latching
RT III (wash tight)
RT II (flux proof)
Test voltage 2000/5000/4000V
Test voltage 2500V
Test voltage 2000V
for Railway applications
Sele
cto
r-D
esc
rip
tio
n
Coil voltages DC 5 6 12 24 48 60 72 110 220
*Standard contact material AgCuNi
**Standard contact material AgSnO
Relays with forcibly guided (mechanically linked) contacts E-Series
Product presentation SRM
MARRE Special Relays
H-507High voltage relay
H-532.1 series
R-2AK seriesHigh DC Loads
R-HEV seriesHigh DC Loads
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 08
Product presentation SRM
MARRE Special Relays
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 09
10A
20A
8.0A
10A
X
X
X
X
002 / 5KV eff
200 / 400VDC
002, 004, 006
200 / 200VDC
H-507 series*
R-HEV series**
H-532.1 series*
R-2 AK series**
Relay series Contact set (NO - NC - CO) Max. switching current
Drivenon-latching latching
Coil voltages DC 6 12 24 60 110 220
*Standard contact material AgCdO + 10µm Au
**Standard contact material AgSnO
Special relays
Product presentation SRM
MARRE Safety Relays Modules
SRM35/64.3 series
SRM70/64.4 series
SRM70/62.2 customized
SRM70/62.2 series
Customized module solution
SRM70/SIP seriesSRM70/64.3 series
SRM40/69.1 seriesSRM40/69.1 series
SRM47/80.2 series
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 10
Product presentation SRM
MARRE Safety Relays Modules
SRM70 seriesSRM70/64.4 / 10 Contacts
SRM70/64.3 / 8 Contacts
SRM70/62.2 / 6 Contacts
SRM70/62.1 / 4 Contacts
24VDC
24VDC
24VDC
24VDC
Coil voltage
SRM70/62.1-024.0
220/001/02/090
Coil voltage
Coil voltage
Coil voltage
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 11
Product presentation SRM
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
MARRE Safety Relays Modules
SRM70 series
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
2x normally open - 2x normally close
3x normally open - 1x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
-Direct current neutral monostable-Current controlled or bistable upon request
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
Contact set configuration
Contact material
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
B1A1A1A1A1
A2A2A2A2
Relay drive circuit
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
DIN Rail mounting
Page 12
A2 A2
A1
/
/
Product presentation SRM
SRM70/62.1 / 4 ContactsRelay drive
General Technical data (short form)
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
MARRE Safety Relays Modules
SRM70 series
5x normally open - 5x normally close
6x normally open - 4x normally close
7x normally open - 3x normally close
8x normally open - 2x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
-Direct current neutral monostable-Current controlled or bistable upon request
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
B1A1A1A1A1
A2A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
DIN Rail mounting
Page 13
Product presentation SRM
SRM70/62.2 / 6 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
MARRE Safety Relays Modules
SRM70 series
5x normally open - 5x normally close
6x normally open - 4x normally close
7x normally open - 3x normally close
8x normally open - 2x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
-Direct current neutral monostable-Current controlled or bistable upon request
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
B1A1A1A1A1
A2A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
DIN Rail mounting
Page 14
Product presentation SRM
SRM70/64.3 / 8 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
MARRE Safety Relays Modules
SRM70 series
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
5x normally open - 5x normally close
6x normally open - 4x normally close
7x normally open - 3x normally close
8x normally open - 2x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
General Technical data (short form)
Contact set configuration
Contact material
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
SRM70/64.4 / 10 Contacts-Direct current neutral monostable-Current controlled or bistable upon request
Relay drive
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
Relay drive circuit
B1A1A1A1A1
A2A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
DIN Rail mounting
Page 15
Product presentation SRM
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
MARRE Safety Relays Modules
SRM19 series
Front connector (10A)
Rack mountingconnection module
Wiring2x normally open - 2x normally close
3x normally open - 1x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
-Direct current neutral monostable-Current controlled or bistable upon request
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
B1A1A1A1A1
A2A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A**
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in / Backplane adapter
Protection IP20 Dimensions LxWxH
Page 16
Product presentation SRM
SRM19/64.3 / 8 ContactsGeneral Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
Relay drive
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
MARRE Safety Relays Modules
SRM19 series
Channel Aredundant
Channel Aredundant2x normally open1x normally close (Monitoring)
2x normally open1x normally close (Monitoring)
2x normally open - 2x normally close
3x normally open - 1x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
-Direct current neutral monostable-Current controlled or bistable upon request
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
B1A1A1A1A1
A2A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 3A
Shock resistance 10gVibration resistance 5g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Backplane adapter
Protection IP20 Dimensions LxWxH
Page 17
Product presentation SRM
SRM19/SIF 2K / 3 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
MARRE Safety Relays Modules
SRM19 series
Relay with forcible guided contacts
MULTI TIMER MODULE
Module supply DC/DC ConverterEN 50155 approvalfor railway applications
2x normally open - 1x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
µC-Timer
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 110VMax. switching current 3A
Shock resistance 10gVibration resistance 5g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Backplane adapter
Protection IP20 Dimensions LxWxH
A1
Start
RESET
A2
µC Timer
Page 18
Product presentation SRM
SRM19/MTM / 3 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays ModulesSRM47/64.3 / 8 Contacts + manual override function
SRM47 series
4x normally open - 4x normally close
5x normally open - 3x normally close
6x normally open - 2x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
A1A1A1
A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 3A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Screw connection terminal block
Protection IP20 Dimensions LxWxH
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 19
Product presentation SRM
SRM47/64.3 / 8 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM22 series
1x normally open - 1x normally close2x change over
AgSnO + 2µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 2 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
A1A1A1
A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 6A
Shock resistance 10gVibration resistance 5g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Screw connection terminal block
Protection IP20 Dimensions LxWxH
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
DIN Rail mounting
Page 20
Product presentation SRM
SRM22/BS.1 / 2 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM22 series
DIN Rail mounting
1x normally open - 1x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
A1A1A1
A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 6A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Screw connection terminal block
Protection IP20 Dimensions LxWxH
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 21
Product presentation SRM
SRM22/69.1 / 2 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM47 series
DIN Rail mounting
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
4x normally open - 2x normally close
AgSnO + 2µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
A1A1A1A1
A2A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 6A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V/4000V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp
Protection IP20 Dimensions LxWxH
Page 22
Product presentation SRM
SRM47/80.1 / 6 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Relays Modules
RM35 series
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
DIN Rail mounting
2x change over
4x change over
6x change over
AgSnO + 10µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 10 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
A1
A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 3,12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 6A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Screw connection terminal block
Protection IP20 Dimensions LxWxH
Page 23
Product presentation SRM
RM35/32.1 / 2 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM45 series
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
DIN Rail mounting
redundant circuit
1x normally open - 1x normally close
AgSnO + 2µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 2 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
A1A1A1
A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 6A
Shock resistance 10gVibration resistance 5g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp
Protection IP20 Dimensions LxWxH
Page 24
Product presentation SRM
SRM45/69.1 / 2x 2 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM40 series
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
DIN Rail mounting
1x normally open - 1x normally close
AgSnO + 2µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 2 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
A1A1A1
A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 6A
Shock resistance 10gVibration resistance 5g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp
Protection IP20 Dimensions LxWxH
Page 25
Product presentation SRM
SRM40/69.1 / 2 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM70 series
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
DIN Rail mounting
5x normally open - 1x normally close
AgSnO + 0.2µm Au
Silver-Tin-Oxide basewith a galvanic gold flashing of 0.2 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgNi becomes dominant
Direct current neutral monostable
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
A1A1A1
A2A2A2
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 8/16A
Shock resistance 10g/8gVibration resistance 10g/5g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
Page 26
Product presentation SRM
SRM70/SIP / 6 Contacts POWERRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM35 series
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
2x normally open - 2x normally close
3x normally open - 1x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgSnO becomes dominant
-Direct current neutral monostable-Current controlled or bistable upon request
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
B1A1A1A1A1
A2A2A2A2
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
DIN Rail mounting
Page 27
Product presentation SRM
SRM35/62.1 / 4 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM35 series
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
3x normally open - 3x normally close
4x normally open - 2x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
-Direct current neutral monostable-Current controlled or bistable upon request
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
B1A1A1A1A1
A2A2A2A2
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
DIN Rail mounting
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgSnO becomes dominant
Page 28
Product presentation SRM
SRM35/62.2 / 6 ContactsRelay drive
General Technical data (short form)
Contact material
Contact set configuration
Relay drive circuit
MARRE Safety Relays Modules
SRM35 series
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
4x normally open - 4x normally close
5x normally open - 3x normally close
3x normally open - 5x normally close
6x normally open - 2x normally close
AgSnO + 5µm Au
Silver-Tin-Oxide basewith a galvanic hard gold plating of 5 μm typical thickness
Contact set configuration
-Direct current neutral monostable-Current controlled or bistable upon request
Direct current neutral monostable (Diode)
Direct current neutral monostable(Suppressor diode)
Direct current neutral monostable (Varistor)
Direct current bistable (Diode)
B1A1A1A1A1
A2A2A2A2
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230VMax. switching current 10A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
General Technical data (short form)
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
DIN Rail mounting
Wide range applications:Small load range (where gold plating erodes very little) from 50 mW (5 V - 2 mA) up to 1.5 W/24 V (resistive load)Middle load range where gold platingerodes after several operations and theproperty of basic AgSnO becomes dominant
Page 29
Product presentation SRM
SRM35/64.3 / 8 ContactsRelay drive
Contact material
Relay drive circuit
MARRE Safety Relays Modules
Automatic Warning System (AWS)Interlocking interface module
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
Electromechanical elementary relayPart 3:Relays with forcibly guided(mechanically linked) contactsIEC 61810-3:2015 / EN 61810-3:2015
WELD NO TRANSFER
Signaling Relayacc. UIC 736e
Railways applicationsDirect current signalling relays EN 50578:2013
1) 1)
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Drive DC (coil voltage) 12, 24, 36, 48, 58, 72, 110VDC
Max. switching voltage 230V/400VMax. switching current 8A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) TÜV, cULus, RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
DIN Rail mounting
customized
Page 30
Product presentation SRM
SRM70/62.2 / customizedGeneral Technical data (short form)
MARRE Safety Relays Modules
customized
Smart Bulb filament monitoring
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
recommended for Railway applications
- Interlocking Interface - - Wayside installations - - Rolling Stock -
1) Relay Approval
Railways applicationsFire protection on railway vehiclesRequirements for fire behaviour of materials and components DIN EN 45545-2:2016-02
Supply voltage 110VDC
Max. switching voltage 12VMax. switching current 6A
Shock resistance 10gVibration resistance 10g
Ambient temperature -25°...+75°C
Test voltage 2500V
Approvals 1) RoHS
Connection Cage clamp, plug in
Protection IP20 Dimensions LxWxH
DIN Rail mounting
Page 31
Product presentation SRM
HFMR / customizedGeneral Technical data (short form)
EuropeUnited Kingdom / Eire
EuropeGermany
EuropeSpain
North americaU.S.A / Canada
J DARBYSHIRE & SON LIMITED
7 Tudor ClosePoulton-le-FyldeLancashireFY6 7TDUnited Kingdom
Phone: +44 1253 893878Fax: +44 1253 891020
Email: [email protected]
MARRÉ GmbH
Mastholterstr. 1733397 Rietberg
Phone: +49 5244 18 50Fax: +49 5244 18 66
Email: [email protected]: www.marre.de
Ctronixx S.L.U
C/ Amadeu Vives,117300 Blanes (Girona)Spanien
Phone: +34 972 336 574
Email: [email protected]: www.ctronixx.com
BREVIS Consulting
PO Box 1745Mattapoisett, MAU.S.A.
Phone: +1 508 758-2441Fax: +1 508 758-2441
Email: [email protected]: www.brevisconsult.com
Partner......globally
MARRE
MARRÉ 2018 - Phone +49 5244 18 50 Email © [email protected]
Page 32