product selector · pdf file · 2014-04-14we hold bsi kitemark accreditation and...

72
Product Selector www.fpmccann.co.uk 2013 Version 1 Image from top right of old cover

Upload: phamtu

Post on 20-Mar-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

Product Selector

www.fpmccann.co.uk

2013 Version 1

Image from top right of old cover

Page 2: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P1Precast ConcreteCivil Engineering Systems

FP McCann is the UK’s market leader in the manufacture, supply and delivery of precast concrete drainage products. The standard range includes a full choice of concrete flexible jointed pipes from DN 225 to DN 2400 including bends, junctions and fittings. Complementary products to complete a pipeline system, include manhole bases and chamber rings, catch-pits, headwalls and gully pots. FP McCann is a member of the Concrete Pipeline Systems Association (CPSA). Our comprehensive precast concrete business extends to include products such as shaft and tunnel segments, power cable ducting, railway components and concrete fencing posts and panels, as well as a bespoke product service to customer specification.Modern manufacturing plants at Alnwick (Northumberland), Ellistown (Leicestershire), Cadeby (Warks), Telford (Shropshire) and Knockloughrim (Northern Ireland) incorporate the latest computerised batching, distribution, casting, curing and handling systems and are operated by skilled and experienced workforces to ensure consistency of quality. Their geographical spread gives us an unrivalled ability to serve the construction industry throughout the UK and Ireland.All our operations are carried out under the auspices of our Integrated Management System, which is accredited to ISO 9001 and ISO 18001. We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. In order to achieve the DC4 design chemical class the raw materials and manfacturing processes meet the design criteria prescribed in BRE Special Digest 1:2005 Concrete in aggressive ground; and are designed for both surface and foul water applications. It is reasonable to expect a correctly designed, installed and maintained pipe line system to achieve a service life in excess of 100 years.This product guide is intended to provide specifiers and contractors with details of the broad range of FP McCann’s precast concrete civil engineering products, including basic information on testing and laying of spigot and socket pipes. Should you require additional information, please contact our Support Team on one of the main contact numbers. The following sources may also be of assistance:

Technical information FP McCann Easi-Base brochure FP McCann quality section of our website at www.fpmccann.co.uk Please refer to FP McCann’s website for Handling & Installation guidelines Concrete Pipeline Systems Association (CPSA) “Complete Technical Guide” WRc’s Sewers for Adoption 7th Edition Civil Engineering Specification for Water Industry

General Information FP McCann website: www.fpmccann.co.uk FP McCann’s policies to include Environmental, Quality and Health & Safety are all available to view on the company’s

website CPSA website: www.concretepipes.co.uk Pipe Jacking Association website: www.pipejacking.org British Precast website: www.britishprecast.org

Accreditations BSI Kitemark accreditation to BS EN 1916 and 1917, along with the relevant parts of BS 5911 Quality Management System accredited to ISO 9001 ISO 18001 Health & Safety Management Environmental Management system to ISO 14001 WRc approved Easi-Base DN1200 - DN2100 Achilles, UVDB/Link-Up Approval

Commitments Sustainability Policy Carbon Reduction Commitment - Carbon Trust BPCF Concrete Targets Lean Construction Health & Safety

FP McCannFP McCann is the trading name of F.P. McCann Limited, incorporated in Northern Ireland, number N.I. 13563.

Page 3: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P2Contents

DrainageSpigot & Socket Pipes 3-5Easi-Flex Oblique Tumbling Junction 6Easi-Flex Square Tumbling Junction 7Easi-Flex Sealing System 8Mechanical Concrete Pipe Lifter 9Easi-Flex Anchor System 10Easi-Slide Wall Pipes 11Easi-Slide Pipes 12Easi-Slide Handling Instructions 13Handling & Laying Instructions 14Easi-Flex Joint Gaps 15DN1200 Easi-Base 16DN1200 Easi-Base Dimensions 17DN1500 - DN1800 Easi-Base 18FPM Tools AutoCAD Toolbar 19Manhole Chamber 20Manhole Soakaways 21Recommended Site Work Practice 22DN4000 Manhole Chamber 23DN4000 Delivery, Handling & Installation Guide 24-25Wide Wall Manhole Chambers 26-27Manhole Cover Slabs & Accessories 28Adjusting Units & Corbel Slabs 29Easi-Safe Fall Arrest System 30House Inspection Chambers (HIC’s) 31Gullies & Slabs Range 32Catchpits 33DN1050 Highways Agency catchpit 34Headwalls 35Easi-Flow Chamber 36Valve Chamber 37Plastic Encapsulated Ladders & Rungs 38Handhold & Entry Pole System 39

Box Culverts 40-41

Water ManagementStorm Water Management 42-43Easi-Storm Attenuation Systems 44Easi-Hydro Separator 45-46Easi-Rain Harvesting Chambers 47

Shafts & Tunnels Shafts & Tunnels 48Smoothbore Shaft & Tunnel Segments 49-52Shaft Cover & Landing Slabs 53-54Caisson Units 55-56Jacking Pipes 57

Infrastructure & PowerPower Infrastructure Cable Ducting Systems 58-62BT Approved Comms Boxes 63-64Easi-Bloc 65

RailwayRail Products 66-67

FencingFencing Products 68

Bespoke Specialist Products 69

Notes 70

Find us on:

Page 4: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P3

Drainage

Nominal Size DN #225 300 375 450 525 600 675 750 825 900 1050 1200 *1350 *1500 *1800 *2100 2400

Internal Diameter A 225 300 375 450 525 600 675 750 805 900 1050 1200 1350 1500 1800 2100 2380

Barrel Diameter B 335 416 505 590 685 790 901 996 975 1080 1266 1460 1620 1800 2130 2460 2750

Socket Diameter C 392 497 575 665 760 852 960 1060 1130 1235 1420 1590 1800 2010 2380 2650 2750

E!ective Length mm 1700 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500

Approx. Weight Kg. 230 450 590 730 975 1245 1820 2160 1690 2060 2760 3630 4290 5330 7300 9160 10070

Reinforced N N N N N N N N Y Y Y Y Y Y Y Y Y

Approx. Pipes per load 150 62 50 40 30 22 15 13 17 13 10 8 6 5 4 3 2

Chamber Ring to suit 1050 1200 1350 1500 1800 2400 2700 3000 3600

MOL Availability Y Y Y Y Y Y Y Y Y Y Y Y N N N N NCrushing Strengths Kn/M 27 36 45 54 63 72 81 90 99 108 126 144 162 180 216 252 288

Easi-Flex Standard Pipes

Easi-Flex Rocker Pipes

Spigot & Socket Pipes

* Easi-Lift Anchors Available

Easi-Flex Rocker Pipes

Easi-Flex Standard Pipes

Nominal Size DN #225 300 375 450 525 600 675 750 825 900 1050 1200 *1350 *1500 *1800

E!ective Length mm 600 600 600 600 600 600 1000 1000 1250 1250 1250 1250 1250 1250 1250

Approx. Weight Kg. 60 145 180 220 300 365 800 950 1020 1020 1200 1605 2020 2755 4440

# Nominal size DN225 – Ireland Only

C BA A B C

Page 5: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P4Spigot & Socket Pipes

Easi-Flex Spigot Butt Pipes

E!ective Length mm 600 600 600 600 600 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250

Approx. Weight Kg. 100 135 155 205 270 870 980 750 910 1170 1585 1850 2230 3005 3800

Drainage

Nominal Size DN 300 375 450 525 600 675 750 900 1050 1200 1350 1500 1800

Internal Diameter mm 300 375 450 525 600 675 750 900 1050 1200 1350 1500 1800

Approximate Weight KG. 140 175 220 290 360 775 925 1140 1515 1955 2425 2965 4105

Easi-Flex Two Piece Bends - 11.25°, 22.5° and 45°

A

B

C

B

A

Easi-Flex Socket Butt Pipes Easi-Flex Spigot Butt Pipes

Easi-Flex Socket Butt Pipes

Nominal Size DN 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800 2100

E!ective Length mm 600 600 600 600 600 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250

Approx. Weight Kg. 145 174 230 270 370 960 1175 945 1105 1500 1930 2435 3100 4300 5400

Page 6: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P5

Nominal Size DN 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800

Branch Size E 150 150 150 150 150 150 150 150 150 150 150 150 150 150

E!ective Length mm 600 600 600 600 600 1000 1000 1250 1250 1250 1250 2500 2500 2500

Approx. Weight Kg. 140 175 220 290 360 800 950 1020 1200 1605 2020 4815 5950 8235

Easi-Flex Fastfit Junctions (Ex-UK)

All junctions are to be fitted on their side. Junctions are not designed for vertical surface compaction and need to

be surrounded in concrete.

Nominal size DN 225 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800 2100

No. of joints per Kg. 32 27 22 18 15 13 12 10 9 9 8 7 6 5 4 4

Pipe Lubricant Pipes should only be joined using an FP McCann approved lubricant

Sold in 2.5kg Tubs

E

Spigot & Socket Pipes

Drainage

Nominal Size DN DN 225 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800 2100

Internal Diameter A 225 300 375 450 525 600 675 750 805 900 1050 1200 1350 1500 1800 2100

Approx. Weight Kg. 200 430 260 390 520 530 850 1200 1900 2000 2600 3500 4200 5100 6800 7100

Easi-Flex Three Piece Bends 90°

Page 7: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P6Easi-Flex ObliqueTumbling Junction

Drainage

Instructions as to use:-Please supply pipe diameter and invert levels only. FP McCann will complete the remaining details and return by fax for customer approval.

Fax: 01530 240013Fax: 028 7964 4224 (N.Ireland)

All bends are manufactured

to ±4° tolerance

Page 8: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P7

All bends are manufactured

to ±4° tolerance

Easi-Flex SquareTumbling Junction

Instructions as to use:-Please supply pipe diameter and invert levels only. FP McCann will complete the remaining details and return by fax for customer approval.

Fax: 01530 240013Fax: 028 7964 4224 (N.Ireland)

Drainage

Page 9: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P8Easi-Flex Sealing System

Cast in Seal Self Aligning Faster and Easier Jointing

Rubber seal onsocket of pipe

Polystyrene covers to beremoved from new pipesbefore use

Easi-Flex Integrated Seal

Easi-Flex System – Glipp Sealing System

Widely used throughout Europe, the Glipp system is designed to improve joint performance, whilst making life easier for ‘the man in the trench’.

Reliable JointsWatertight JointsSimplified JointingLong, Reliable Service Life

Easi-Flex is a system in which the seal forms an integrated part of the pipe joint. The position of the sealing ring is fixed in the socket, which guarantees watertight and secure pipe joints.

The Easi-Flex joint is a sliding joint. This requires the application of lubricant to the spigot prior to assembly. Sliding joints have an advantage that, if sand, gravel or clay stick on the spigot, they are easily wiped off the sealing surface during assembly. The Cast-in protective strip ensures the seal is in the correct position during manufacture.

The Protective Strip also ensures that the pipe socket is ‘clean’ and free from dirt, stones, mud etc prior to jointing. The Protective Strip is made of a non-toxic cellular plastic material. Details are available upon request.

 

Drainage

Page 10: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P9

The Concrete Pipe Lifter is designed to off-load and install concrete drainage pipes in a simple, efficient and extremely safe procedure. In a single manoeuvre a pipe can be lifted from the delivery vehicle and placed in the ground. The banksman is not required on the trailer body to off-load and operatives are not required in the excavation during mechanical pipe installation.Designed as an excavator attachment, all moving parts are mechanical and do not require the excavator to have additional hydraulic systems. The Pipe Lifter has the following design features:

30 degree tilt for guiding the pipe into position A swivel plate allowing the pipe lifter to turn at 90 degree intervals Tested to a safe working load (S.W.L) 3700kg

Technical Information:Lifts Pipe Dimensions: DN300 to DN1200 Max Length: 2500mmMain Dimension: H 1600mm L 1530mmPipe Lifter Weight: Approx 600kg

Key Benefits and Safety Features: Increases safety significantly during pipe off-loading and installation Quick-hitch coupling to excavator arm in seconds Saves time in installation - Up to 50% faster Up to 30% increase in pipe laying productivity

Version 2 of the pipe lifter is currently in development and will possess the ability to offload pipes up to DN1800 with a release date scheduled for 2013.

To find out more visit:www.concretepipes.co.uk/transport-handling-installation.php

Mechanical Concrete Pipe Lifter

Drainage

To buy or rent the Pipe Lifter call FP McCann’s supply partner MGF

on 01942 402700 or go to www.mgf.ltd.uk

Page 11: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P10

Use the equal lengths (1 & 2) for lifting the pipe.Join the longer chain (3) onto the pipe already laid and place the shorter length (2) onto the hook.The pipe can then be jointed without moving the jib of the crane.

The chain setEngaging and disengaging the eye

Lifting & handlingJointing

1

1 1

2

22

3

3

Nominal size DN 225 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800 2100 2400

Anchor Availability X X X X X X X X X X X X Y Y Y Y Y

Easi-Flex anchor system available from 1350mm diameter upwards(Available in DN1200 in NI only)

FP McCann pipes from DN1350 should be handled using our purpose designed Easi-Flex Anchor System. Special lifting Anchors can be cast into pipes at manufacture. A Universal Head Link (Available from FP McCann) can then be hooked onto the exposed anchor heads to lift the pipe.

WARNING When Lifting !45°Inclined pull only

Easi-Flex Anchor System

Drainage

Page 12: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P11

Easi-Slide Standard Pipes (Wet-Cast Ex-Alnwick) Nominal Size DN 1800 2100 2400

Internal Diameter A 1830 2076 2380

Barrel Diameter B 2140 2410 2750

E!ective Length C 2500 2500 2500

Approx. Weight Kg. 6525 7960 10070

Pipes per Load Qty 4 3 2

Easi-Slide Spigot/Socket Butt PipesNominal Size DN 1800 2100 2400

Internal Diameter A 1830 2076 2380

Barrel Diameter B 2140 2410 2750

E!ective Length C 1250 1250 1250

Approx. Weight Kg. 3370 4095 5195

Easi-Slide In Wall Pipes

Fastfits Available150mm Super sleeve

made to order

Easi-Slide Rocker Pipes (Wet-Cast Ex-Alnwick)Nominal Size DN 1800 2100 2400

Internal Diameter A 1830 2076 2380

Barrel Diameter B 2140 2410 2750

E!ective Length C 1250 1250 1250

Approx. Weight Kg. 3310 4010 5040

Note: All junctions are to be fitted on their side. Junctions are not designed for vertical surface compaction.

Drainage

Easi-slide Right Angle (90°) Reduced JunctionNominal Size A 1800 2100 2400

Branch Supersleve B 100 100 100

Branch Supersleve B 150 150 150

E!ective Length C 2500 2500 2500

Approx. Weight Kg. 6525 7960 10070

Nominal Size A 1800 2100 2400

Branch Supersleve B 100 100 100

Branch Supersleve B 150 150 150

E!ective Length C 2500 2500 2500

Approx. Weight Kg. 6525 7960 10070

Easi-slide Oblique (45°) Reduced Junction (Wet-Cast Ex-Alnwick)

Page 13: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P12

Easi-Slide Two Piece Bends (Wet-Cast Ex-Alnwick)

Nominal Size DN 1800 2100 2400

Internal Diameter A 1830 2076 2380

Angle "° 11.25 # # #

Angle "° 22.5 # # #

Angle "° 45 # # #

Easi-Slide PipesEasi- Slide Spigot Butt Pipes

Nominal Size DN 1800 2100 2400

Internal Diameter A 1830 2076 2380

Barrel Diameter B 2140 2410 2750

Effective Length C 1250 1250 1250

Approx. Weight Kg. 3020 3610 4670

All bends are manufactured

to ±4° tolerance

Drainage

Page 14: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P13

Handling/Lifting Instructions

Pipe Diameters DN1800 to DN2400 are designed and manufactured to incorporate Easi-Lift jointing and lifting system.

Easi-Lift System

To lift the pipes, select the two short legs A and B on the chain set. Place the spherical coupling over the cast in anchor and engage by turning the tail of the head link down to the concrete. The pipe can then be lifted as normal.Never pass slings or other lifting appliances through the barrel and never lift more than one pipe at a time.

Jointing

Ensure that the seal is of the correct size, and is not damaged.Ensure pipe sockets and spigots are not damaged. Position the rubber ring on the end of the spigot end.

Do not use Lubricants when jointing Easi-Slide Pipes.Ensure each pipe to be laid is aligned with the laid pipeline and is fully supported along its length.Recommended method of joining pipes is shown below.

To joint the pipe using the chain system, attach the long leg C to the already laid pipe and the short leg B to the pipe to be laid. Take up the slack in the chains with the lifting pulley over the anchor of the laid pipe, and increase the upward force to joint the pipes. When jointed, ensure that there is no excessive slew or misalignment, this can easily be checked by reference to the joint gap.

Notes:1. All dimensions are in mm.2. Weights in kg are based on a concrete density of

2500kg/m!.3. Where relevant pipes are manufactured in accordance with BS EN 1916.4. Normal practice is to determine left or right branch

laterals to the main line by looking up the flow i.e. From the socket end.

5. Note right hand or left hand junctions (viewed socket to spigot) should be specified when ordering reduced junctions in pipe diameters DN1800 and above.

6. Note lifting chains are not suitable for joining purposes in pipes of diameter DN2400. Joint in the traditional method.

7. Do not install vertical junctions.

The Lift

Ensure the tension is even.

Easi-Lift joint

Easi-Slide Handling Instructions

A BC

Joint Gap

A

B C

WARNING When Lifting !45°Inclined pull only

Nominal size 1800 2100 2400

Medium Duty Chain Set 3 3 X

Heavy Duty Chain Set X X 3*

Easi-slide Lifting Chains

*Only suitable for Lifting not Jointing

Drainage

Page 15: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P14Handling & Laying Instructions

Recommended Site Work Practice – Open Cut Flexible Jointed Pipes

Handling & Storing Pipes1. Time and place of off-loading should be agreed before the units arrive at site. The contractor should provide suitable equipment for off-loading, stacking and

stringing out of pipes on site.2. Off-loading should take place at the nearest hard road to the point of installation. To ensure the safety of all personnel, units must be left in a stable position

well clear of the edge of the trench.3. Pipes should be inspected before off-loading to ensure that materials delivered correspond to order placed.4. Pipes should be carefully checked during off-loading to ensure no units are damaged. Any discrepancies should be

recorded on the delivery docket.5. Where stacking is necessary, this should be done on level ground and the bottom layer of pipes securely chocked to

prevent the stack from collapsing. Pipes should be supported under the barrel so that the socket is free of load so that the jointing faces are not damaged. They should preferably be stacked barrel to barrel with sockets hanging over alternative sides.

6. For safety reasons and to prevent damage to the lower layers of pipe in the stack, pipes should not be loaded or stacked in a greater number of layers than is shown in the table below.

7. Avoid damage when handling, especially to ends of concrete pipes. Never drag or roll pipes over the ground.

Note: FP McCann Easi-Flex pipes from DN1350 can be handled using our purpose designed Anchor System. Special lifting Anchors can be cast into pipes at manufacture. A Universal Head Link (Available from FP McCann) can then be hooked onto the exposed anchor heads to lift the pipe. Lifting Anchors are fitted to order.

Laying Pipes1. Trench Excavation - The trench should be excavated to the line, gradient and width indicated in the contract documents or as agreed with the engineer. The

safety of the public and site personnel is of paramount importance and care should be taken to ensure personal safety at all times.2. Trench Width - Any increase in trench width above that specified could increase the load on the pipe; increasing the quantity of excavation and the bedding

material required. A trench narrower than the specified width may impede the proper placing of bedding or backfill material or the correct jointing of pipes.3. Formation - Uniform support along the pipeline is essential. Rock outcrops and soft zones, which can cause differential settlement should be dug out and

replaced with compacted specified backfill material. De-watering may be necessary during pipe laying and subsequent backfilling operations. The specified bedding material shall be placed as detailed in the contract specification and trimmed to ensure uniform support of the pipe throughout the length of its barrel. Recesses should be prepared for the pipe sockets.

4. Pipe Laying - Before being lowered into the trench, pipes and fittings should be inspected to ensure that they have not been damaged during handling and storage on site. Units should be lowered carefully into the trench using recognised lifting tackle such as the Easi-Lift mechanical pipe lifter.

5. Jointing - Using our integral Easi-Flex Sealing System all pipe spigots must be fully lubricated with the pipe lube supplied just prior to being lowered into the trench. Please note, pipes should only be joined using an FP McCann approved lubricant. The socket of the laid pipe should at this stage be prepared by removing the polystyrene forming ring to leave a clean seal free from debris. The adjoining pipe should be lowered into position as level as possible centring the pipe spigot with the seal of the laid pipe so that the pipes are in line. On achieving this apply pressure to the socket end of the adjoining pipe using a substantial piece of timber to protect the pipe from damage when pushing the pipe home.

6. Testing - Acceptance tests on the completed pipeline give an indication of the level of control of workmanship and materials during construction.7. Visual Testing - Check for obstructions and debris within the pipe, the structural soundness of pipes, that joints are properly sealed and that the pipe invert is

even. Note: pipes smaller than DN750 may be inspected from manholes or by means of TV cameras.8. Water Tightness - The water tightness of a pipeline may be checked using a water or air test. Such tests will reveal the existence of cracked or porous pipes

or faulty joints. These tests should be made during and after laying and before backfilling. The test method will be detailed in the contract specification or referenced to an appropriate code of practice. In certain circumstances (e.g. where the distance between manholes is great, or when site conditions are such that backfilling must take place immediately or when laying small diameter pipelines), it is recommended that the pipeline be tested at regular intervals (say every 3 pipes) during construction.

9. Backfilling - After inspection and testing backfilling should proceed. The attention given to backfill selection is of great importance. The placing and compaction of inappropriate backfill may cause damage to a new pipeline. The structural strength of the completed pipeline depends as much on good site workmanship as on the strength of individual pipes. Consequently all backfill material must be selected and placed as detailed in the contract specification or recognised code of practice.

Note: For additional information on laying pipes see the CPSA website.www.concretepipes.co.uk/technicalguides/index.html

2.0

M M

ax

Chocks

DN No of layers

300 - 375 4

450 - 600 3

750 - 900 2

> 1050 1

Drainage

Page 16: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P15

Pipe DN Nominal Joint Gap Maximum Joint Gap Maximum Deflection

225 4mm 20mm 2 Deg

300 4mm 34mm 2 Deg

375 4mm 34mm 2 Deg

450 4mm 34mm 2 Deg

525 4mm 34mm 2 Deg

600 4mm 34mm 2 Deg

675 4mm 34mm 1Deg

750 4mm 34mm 1 Deg

825 4mm 34mm 1 Deg

900 4mm 34mm 1 Deg

1050 4mm 34mm 1 Deg

1200 5mm 36mm 1 Deg

1350 5mm 36mm 0.5 Deg

1500 5mm 36mm 0.5 Deg

1800 7mm 41mm 0.5 Deg

2100 7mm 41mm 0.5 Deg

The maximum joint is calculated (seal gauge point - spigot chamfer - tolerance + nominal joint gap) or for DN450mm (55mm - 20mm - 5mm + 4mm = 34mm).

Easi-Flex Joint Gaps

Drainage

Page 17: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P16

“Concrete and Polypropylene make an ideal combination” PREDL®“80 Year Guarantee on all Easi-Base” - FP McCann

A prefabricated manhole base unit with integral benching, channels and connectors that provides an immediate and long-lasting watertight solution in the management of waste water.

Benefits of using the Easi-Base

Can be installed in as little as 30 minutes

Offers cost benefits with reductions in construction time and skilled resource requirements due to prefabrication

Provides immediate watertight structure, allowing quicker follow-up of subsequent construction activities

Accommodates all combinations and variations in entry / exit pipes up to DN 300mm

Improves safety of construction (slips / trips and other hazards), as pre-formed base and channels reduce the number of site operations thus avoiding the need for personnel to repeatedly climb in and out of manhole during construction

Provides a solution that offers increased confidence in ability to meet industry standards

Environmental advantages - less concrete used and less excavated material removed from site

Eliminates material wastage associated with current practice in manhole base construction

Clean access for inspection. Reduces maintenance and long-term running costs

Easi-Base connects with any type of pipe and is compatible with the new DN 1200 130mm wide wall chamber ring.

DN1200 Easi-Base (Polypropylene lined)

Easi-Base is a kitemark product,

manufactured and testedto BSEN1917:2002 PT/274/0808 (PP)

An Easi-Manhole installation can be viewed at:www.youtube.co.uk/fpmccann

Approved for use in manhole construction in accordance with Sewers for Adoption 7th edition

Page 18: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P17

Features

The DN1200 Easi-Base is made to an internal diameter of 1200mm with tongue and groove joint profile to match standard DN1200 manhole chamber rings.

Wall thickness is 150mm. The base has a 150mm floor thickness with the outlet invert at exactly 150mm from ground level. A 1% fall exists across the channel toward the outlet (1:100). A gradient of 1:10 is present at the benching with the run-off toward the channel. The height of the DN1200 Easi-Base unit varies in accordance with the diameter of the main channel running through the unit. (Please refer to the table above for approximate heights).The DN1200 Easi-Base unit has 5° flexibility in the seal at each pipe connection point, this can be achieved both horizontally and vertically. (This is best illustrated in the diagram below).Additional connections can be made to a DN1200 Easi-Base unit once installed. This can be achieved either by coring into the existing unit and fitting a connection in the traditional manner; alternatively by the use of a backdrop into the manhole.

Easi-Base is a Kitemark product - manufactured and tested to BSEN 1917. Easi-Base meets with WRc Approval. Easi- Base is accepted for use by all major UK water companies.

Note: A copy of the WRc Approval and copies of water company acceptance letters are available through our website or upon request.

DN1200 Easi-Base Dimensions

Easi-Base is a kitemark product,

manufactured and testedto BSEN1917:2002

PT/274/0808

Channel Depth (mm)

Easi-Base Height(mm)

Invert to Base Top(mm)

150 520 370

200 570 420

225 620 470

250 620 470

300 670 520

Invert Height

520m

m -

670m

m

1200mm150mm

160mm 150mm

5°IN OUT

10%

1%

Unit weights vary between 1.5 tonnes and 2.5 tonnes depending on channel diameters and channel configuration.

DN1200 12mm x 120mm x 4.2mDN1500 12mm x 120mm x 5.2mDN1800 12mm x 120mm x 6.0m

Sealant

FP McCann cannot accept responsibility for joint failure where pipe connection has been undertaken by the contractor outside of manufacturer’s installation guidelines. FP McCann has designed their jointing system to fit many types of plastic, clay, concrete and iron pipes; however it is the responsibility of the contractor to ensure complete satisfaction with the connection between the chosen pipe and the Easi-Base.

Page 19: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P18DN1500 - DN1800 Easi-BaseDN 1500 & DN 1800 Precast Concrete Easi-Base

The Easi-Base range extends to include the larger diameter DN 1500 and DN 1800 concrete manhole bases. These bases will accommodate concrete, clay, twin wall and uPVC pipes from DN 150 to DN 900mm.

Bases are traditionally constructed manually in-situ using ready mix concrete which is troweled to form the base and benching. This practice is labour intensive and requires optimum site conditions to achieve a quality result. The Easi-Base precast alternative removes many of the variable factors in the manual process.

PT/279/0109 (Concrete)

Benching and channels are generally pre-formed with concrete. The DN 1500 and DN 1800 units are WRc approved and offer the same construction benefits as the DN 1200 Easi-Base.

Page 20: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P19FPM Tools AutoCAD

www.microdrainage.co.uk

The FPM Auto-CAD toolbar is a set of instructions designed for AutoCAD and aimed mainly at Civil Engineers, Quantity Surveyors and estimators used to produce quick and accurate ‘drainage take offs’.It provides tabular data for the drainage layout, and specifies the relevant FP McCann Easi-Bases automatically.The FPM Tools toolbar is used to work through the drainage plan in sequence, specifying each manhole in turn. Manhole references, invert levels, cover levels, pipe types and pipe lengths are all recorded. When complete, a table is generated within the actual plan. This table can then be exported as a .csv file and opened in excel or other similar supporting program.

Subscribers to Micro Drainage’s WinDes 2013.1 sustainable drainage software, can incorporate Easi-Base into quick and accurate drainage scheduling in accordance with the Predl clock notation.

The screen shot above shows the drainage table generated within AutoCAD and the exported Excel table ready for the quantity surveyor / buyer /estimator to send out for pricing.

From within AutoCAD, the Manhole Edit tool can be used to assemble the manhole and pipe data at a particular manhole reference within the plan.

Page 21: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P20

Manhole Chambers (Tongue & Groove Joint)Nominal Size (A)

(DN) 1000mm 750mm 500mm 250mm

Wall Thickness (C)

mm

litres/meters

Barrel Diameter (B)

mm

Approx Weight

Kg. (p/meter)

Approx. Productsper load

Qty.(meter)

Lifting HoleQty/dia(p/Unit)

900 # # # # 70 656 1040 520 38 3x45mm dia

1050 # # # # 80 894 1210 690 34 3x45mm dia

1200 # # # # 90 1167 1380 880 26 3x45mm dia

1350 # # # 95 1478 1540 1050 22 3x45mm dia

1500 # # # 100 1824 1710 1300 16 3x45mm dia

1800 # # # 115 2544 2030 1750 12 3x45mm dia

2100 # # # 125 3464 2350 2040 10 4x50mm dia

2400 # # # 140 4514 2680 2790 8 4x50mm dia

2700 # # # 150 5725 3000 3370 8 4x50mm dia

3000 # # # 210 7069 3420 5050 5 4x50mm dia

*3600 # # # 185 10179 3970 5400 5 4x50mm dia

*4000 # # 200 12566 4400 6800 1.5 4x50mm dia

Dia ± 5mm

Available Depth of Section (D)

Tongue and Groove Joint Profile

Product Information * DN 3600 and DN 4000 are not covered by the British Standard (Non-Kitemark), but comply with all relevant provisions of the European

Standard. DN 4000 is supplied in two halves (see seperate jointing instructions).

Manhole chambers ex-Ellistown from DN2100 - DN3600 have 4 lifting points. Manholes less than DN2100 have 3 lifting points.Manhole chambers ex-Knockloughrim from DN900 -DN2700 have 3 lifting points. DN3000 have 4 lifting points.

Manhole Chambers

WARNING When Lifting !45°Inclined pull only

MOL from 900-2700 Upon Request

DrainageC

Page 22: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P21

Nominal Size(DN)

Sealant Size(metres)

No. of rolls p/joint(metres)

Rolls Required Quantity

900 20x20x4m 0.88 1

1050 20x20x4m 1.00 1

1200 20x40x4m 1.13 2

1350 20x40x4m 1.25 2

1500 20x40x4m 1.38 2

1800 20x40x4m 1.63 2

2100 20x40x4m 1.88 2

2400 20x40x4m 2.13 3

2700 20x40x4m 2.38 3

3000 12x120x6m 1.75 2

3600 12x120x6m 2.08 3

4000 12x120x6m 2.33 3

Sealing Strip

Please note this is a guideline based on sealant supplied by FP McCann only.

Nominal Size

(DN) 1000mm 750mm 500mm

Wall Thickness

mm

litres/meters

Barrel Diameter

mm

Approx Weight

Kg. (p/metre)

Approx. Productsper load

Qty.

900 11 9 6 70 656 1040 520 46

1050 11 9 6 80 894 1210 690 34

1200 13 10 7 90 1167 1380 880 26

1350 15 12 8 95 1478 1540 1050 22

1500 16 12 8 100 1824 1710 1300 18

1800 19 15 10 115 2544 2030 1750 12

2100 22 17 11 125 3464 2350 2040 10

2400 26 20 13 140 4514 2680 2790 8

2700 29 22 15 150 5725 3000 3370 6

3000 32 24 16 210 7069 3420 5050 5

*3600 40 30 20 185 10179 3970 5400 5

*4000 45 34 23 200 12566 4400 6800 1.5

Manhole Soakaway Chambers

No. of 75mm holes per Chamber

Manhole Soakaways

* DN3600/4000 - See Page 19 Manhole Chambers

Drainage

Page 23: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P22

Handling & Installing Manholes1. Time and place of off-loading should be agreed before the units arrive at site. The contractor should provide suitable

equipment for off-loading. For safety, all chamber sections are delivered chimney fashion.2. Off-loading should take place at the nearest hard road to the point of installation. When off-loaded, units should never

be stored on their side (on the roll), but should always be laid in the “as installed” position.3. Carefully inspect units during off-loading to verify that products are undamaged and comply with order placed. Note

any discrepancies on the delivery docket.

Recommended Site Work Practice – Manhole Chambers

ConstructionTo ensure that the manhole structure is vertical, accurate levelling of the formation or the in-situ concrete foundation is essential.Tongue and groove joints should be installed with the socket facing upward. Manhole sections fitted with double steps can be used in any depth configuration. However, it is recommended that the deepest section of manhole units should be used whenever possible in order to minimise the number of joints and costs. Precast cover slabs can be laid directly onto the shaft or chamber rings.To allow for any differential settlement between manhole and pipeline, a flexible joint incorporating short length rocker pipes should be constructed as close as possible to the outside of the manhole or the concrete surround if used. Extra care must be taken to ensure that joints are properly made.

JointingPrecast manhole components are provided with joints formed within the wall section. These are sealed with cement / sand mortar or with proprietary mastic sealants. Precast concrete manhole units, well jointed, provide an adequate seal under normal conditions.

ReinstatementIn-situ concrete surround to precast concrete manholes is not necessary as a well constructed precast manhole is a strong durable structure with its own inherent strength and would only require a surround for exceptional structural reasons. However under some specifications a concrete surround is required where the depth from ground level to the base of the concrete chamber rings, exceeds 4.5m. Such surround should be of 150mm thickness. Backfilling should take place as each precast manhole section is placed. It must be brought up evenly and compacted around the manhole to prevent displacement.

TestingIt is generally unnecessary to apply water tests to manholes. In working conditions manholes are not normally full of water.Prevention of infiltration is of more relevance than ex-filtration. If infiltration does occur it can be seen and remedied by sealing using an appropriate method.

Note: When handling precast products on site it is recommended that the contractor has the correct lifting equipment in place and adheres to the relevant lifting guidelines and standards. Refer to:- www.concretepipes.co.uk/technicalguides/index.php

Recommended Lifting Equipment

Lifting HoleQty/dia(p/Unit)

36mmLifting Pin3.5 t SWL

42mmLifting Pin3.5 t SWL

3 leg Lifting

Chain 3.1t

4 leg Lifting

Chain SWL 6.7 t

3x45mm dia # #

3x45mm dia # #

3x45mm dia # #

3x45mm dia # #

3x45mm dia # #

3x45mm dia # #

4x50mm dia # #

4x50mm dia # #

4x50mm dia # #

4x50mm dia # #

4x50mm dia # #

4x50mm dia # #

Dia + 5mm

Drainage

Page 24: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P23DN4000 Manhole ChamberThe DN4000 manhole chamber sections can be used in a variety of applications to include the following:

Water Treatment PlantsStormwater Attenuation SystemsStorage tanksCatchpits

The DN4000 chamber ring is supplied with standard tongue and groove joint, connecting bolts and butyl rubber sealant for jointing purposes. The units are designed for use with the FP McCann ladder system with holes preformed in the wall at 4 locations around the ring 3140mm apart.

The 4 metre chamber section comes as a two part unit, which allows for:

Ease of transportEase of handling

DN 4000 Chamber section

Nominal SizeDN

Section Depth Wall thickness Approx. weight of half section

Approx. weight of section when jointed

mm mm mm kg kg4000 1000 200 3400 68004000 750 200 2550 5100

DN 4000 Cover slab – 2 piece unit (Detail for standard 600 & 675 openings)

Heavy duty cover to suit chamber

section DN

Effective thickness Overall thickness Overall diameter Approx. weight of half section

Approx. weight of combined sections

mm mm mm mm kg kg4000 300 300 4500 6450 11700

Cover slabs are manufactured in two sections, supplied with standard openings.Standard cover slabs are designed to withstand 30 units of Type HB loading, applied in accordance with British Standard 5400: Part 2. If required, cover slabs can be designed to withstand 45 units of Type HB loading.

For special opening cover slabs an engineering drawing may be required in order to achieve desired loading requirement.

Note: FP McCann provide a technical installation sheet which must be adhered to when installing DN4000 manhole chambers, this is available online or from our sales team.

Drainage

Page 25: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P24DN4000 Delivery, Handling& Installation Guide

Drainage

FP McCann 4000mm diameter rings are supplied in half sections for ease of transport and handling on site. They are provided with three lifting points to facilitate off-loading.

IMPORTANT SAFETY NOTE: The angle of the chain used to handle the units must not be less than 60 degrees.

PLEASE NOTE THIS SEQUENCE IS INDICATIVE ONLY AND THE EXACT METHOD OF INSTALLATION IS THE RESPONSIBILITY OF THE CONTRACTOR. HEALTH AND SAFETY MEASURES THAT APPLY SPECIFICALLY TO EITHER CHAMBER OR MANHOLE UNITS AND THEIR FITTINGS ARE INDICATED, OTHER MEASURES THAT APPLY SUCH AS GUARD RAILS AND SITE PROVISIONS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.

CHAMBER RING:

will normally have two sets of eight sockets on the inner face to accept step rungs

o The pins are passed through the wall with the eye of the pin on the inside o The plate and the wingnut are tightened up on the outside of the ring o The unit must NOT be lifted without the nut being applied

+ appropriate safety factors) We suggest a four-leg set of chains with adjustment clutches to vary the lengths as shown

o Outer legs must be 3565mm long assuming a 60degree lift o Middle leg must be 3146mm long assuming a 60degree lift

together with a chain block, or you can use a strap and ratchet around the outside of the ring to mate them. Take care not to damage the dowels or the concrete at this time

THE JOINT

using four of the lifting pins, namely those that would be to your left and right if you were to stand in the centre of the ring, and not the centre ones

o Legs must be 4205mm long assuming a 60degree lift

previous unit. If installing rungs, they should be rotated to ensure rung holes are aligned correctly

Page 26: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P25

General Information:

into position as a complete item with four equally spaced lifting points

this with your sales contact

if slabs are required

Appropriate working at height safety precautions should be made by the contractor

Drainage

Please contact our sales office for further information

DN4000 Delivery, Handling& Installation Guide

Page 27: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P26

DN 1200mm, 1500mm & 1800mm Wide Wall Manhole Chamber A 130mm thick wide wall chamber in combination with the Easi Base unit, provides a sealed watertight manhole system. This robust design means that the requirement for a concrete surround is eliminated.

Advantages Speed and ease of installation Watertight on construction

Wide Wall Manhole Chambers

Nominal Size (DN) 1000mm 750mm 500mm 250mm

Wall Thickness

mm

Barrel Diameter

mm

Approx Weight

Kg. (p/meter)

Approx. Productsper load

Qty.(meter)

DEHA Lifting AnchorsQty/dia

1200 # # # # 130 1460 1520 16 3x45mm dia

1500 # # # 130 1760 1645 14 3x45mm dia

1800 # # # 130 2060 1970 12 3x45mm dia

Available Depth of Section

FP McCann wide wall manholes have been designed with a tongue and groove dimension to accommodate the use of bituminous sealant. An FP McCann approved sealant should be used at all times. The sealant requirement for wide wall manholes is 12mm x 120mm x 6m. When placing sealing strip into position during installation, the ends of the strips must be overlapped by a minimum of 30mm and cut at an angle of 60 degree. The cut ends must then be pressed together. Full installation guidelines can be provided upon request or can be found at www.fpmccann.co.uk

Approved for use in manhole construction in accordance with Sewers for Adoption 7th Edition.

Drainage

Page 28: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P27

Nominal Size (DN) 1000mm 750mm 500mm 250mm

Wall Thickness

mm

Barrel Diameter

mm

Approx WeightKg. (p/meter)

Approx. Productsper load

Qty.(meter)

Lifting Point

Qty/dia(p/Unit)

36mm Lifting Pin 0.75 t SWL

42mm Lifting Pin 3.5 t SWL

3 leg Lifting Chain SWL

3.1t

1200 # # # # 130 1460 1520 16 3x45mm dia Lifting clutches.

F P McCann supply

recommended and

approved lifting clutches.

#

1500 # # # 130 1760 1645 14 3x45mm dia #

1800 # # # 130 2060 1970 12 3x45mm dia #

Available Depth of Section

1520 KG

Wide Wall Manhole Chambers

Drainage

Page 29: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P28

C

B A

Cover Slabs

STANDARD COVER SLABS STANDARD REDUCING SLABSShaft or Chamber Nominal

Size DN (mm)Outside Diameter

(A) Slab Thickness (C)Opening Con!guration B Approximate Weight

(KG)Opening Diameter B

(mm)Effective Depth

(mm)Approximate Weight

(KG)Size (mm) Location

900 1080 150 600x600 CENTRAL 215675x675

1050 1240 150600x600

ECCENTRIC315675x675

750x750 CENTRAL

1200 1420 150600x600

ECCENTRIC 455 900 250 385675x675750x600

1350 1580 170

600x600ECCENTRIC

6501050 250 695

675x675750x600

1200 250 5501200x675 CENTRAL

1500 1740 175

600x600ECCENTRIC

980900

10501200

250250250

981835680

675x675750x600

1200x675 CENTRAL

1800 2070 175

600x600

ECCENTRIC 1460900

10501200

250250250

149513501220

675x675750x600

1200x675

2100 2380 200

600x600

ECCENTRIC 2180900

10501200

250250250

213026902540

675x675750x600

1200x675

2400 2710 200

600x600

ECCENTRIC 2800900

10501200

250250250

281526902540

675x675750x600

1200x675

2700 3030 230

600x600

ECCENTRIC 3750900

10501200

250250250

369535503410

675x675750x600

1200x675

3000 3420 213

600x600

ECCENTRIC 4970900

10501200

250250250

497049704970

675x675750x600

1200x675

*3600 Two Piece

4000 300

600x600

ECCENTRIC 9250675x675750x600

1200x675

*4000Two Piece

4500 300

600x600

ECCENTRIC 11700675x675750x600

1200x675

Reducing SlabsA

B

C

Manhole Cover Slabs & Accessories

Chamber Section (DN) Outside Diameter (A) Opening Diameter (B) Slab Thickness (C) Approx. Weight (Kg.)1500 1730 900 175 8261800 2050 900 175 12922100 2375 900 200 20302400 2705 900 200 26002700 3025 900 230 38803000 3330 900 213 4500

Landing Slabs

B

A

C

MULTIPLE ACCESS/OTHER ACCESS SIZED COVER SLABS CAN BE MADE TO ORDER

Covers to suit Manholes greater than or equal to 1.5m deep cover level to pipe soffit.

* 3600mm and 4000mm diameter cover slabs come in a 2 piece unit

Drainage

Note: Cover Slab sizes 900-3000 are manufactured in accordance with BS5911-3. 3600 & 4000 cover slabs are generally designed in accordance with BS 5400-2, (for 30 units of Type HB loading, can also be designed to withstand 45 units of Type HB loading).* Weights for 3600 and 4000 are estimated weights based on solid slabs.

Page 30: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P29Adjusting Units & Corbel Slabs

Size (A) (mm) Slab Thickness (C) (mm) Openings (B) (mm) Approx. Weight (Kg.)

*1125x1125 75 600x600/ 675x675 /750x600 140*1125x1125 150 600x600/ 675x675 /750x600 290

Lothian Slab

B A

C

FP McCann manufactures a full range of adjusting units and corbel slabs that have the following advantages:

Note: A 600 x 600 eccentric corbel slab is also available when using a ladder BS EN 1917 and BS 5911-3

600x600 675x675 750x600

750x750 1200x675 600x600 Eccentric (Corbel)

*Scotland & Ireland Only

Diameter Opening Size No per Pack Thickness Weight1050 600 x 600 15 65 701050 675 x 675 15 65 551050 750 x 600 15 65 601050 750 x 750 10 65 45

1575 x 1050 1200 x 675 6 75 1601175 x 1025 600 x 600 10 65 125

Drainage

Page 31: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P30Easi-Safe Fall Arrest System

Award Winning Safety Solution For Manhole Construction

The client, consultant engineer, contractors and suppliers all have a duty to mitigate hazards on site whenever reasonably practicable. One such hazard identified is the risk of operatives falling through manhole openings particularly during the construction process and also in follow up maintenance work.

Working with partners Severn Trent Water, engineer Grontmij and contractor to the water sector, Morgan Sindall plc, FP McCann have designed a safety award winning solution. Easi-Safe is a temporary or permanent fall arrest system that allows for safe working around the manhole opening prior to the fitting of the ironwork. In the construction of a manhole, operatives often work unprotected from the opening at surface level when the final stages of completion occur. This includes the final brickwork up to the manhole frame and the mortar bedding of the frame itself.

With most standard cover slabs, the access point for man entry is open and it is left to the contractor to cover on site. In many site situations these openings remain for a number of days while gangs complete phases of work. Easi-Safe immediately addresses this problem. The future production of all standard access cover slabs will incorporate the optional protective grid which will remain in the slab even when the final D400 steel cover and frame are set in place at surface level.

The galvanised mild steel grid is available in four standard sizes:-610mm x 610mm675mm x 675mm750mm x 600mm1200mm x 675mm

The Easi-Safe grid is seated on load bearing corners cast into a standard range of manhole cover slabs. As a temporary fall arrest system, once the construction of the manhole is complete, the grid can be removed prior to the fitting of the ironwork. Alternatively, Easi-Safe can be a permanent fixture, left in place beneath the manhole lid. The spacing between the bars allows for ease of inspection and jetting of the manhole base during maintenance work.

UNPROTECTED

Drainage

Page 32: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P31House Inspection Chambers

FP McCann Inspection chambers are available in four common sizes: 600x450, 750x600, 1000x675 and 1200x750. Each section has a tongue and groove joint and can be sealed with a sand-cement mortar or bitumen sealant in the same fashion as a circular manhole and chamber ring.

HIC cover slabs can be provided to meet both main road and light road requirements.* Effective thickness ** Approximate weights

Description Units (mm) Weight per No of units Wall/Slab unit Kg** per pallet thickness(mm)

600 x 450 x 150 section 40 12 40 600 x 450 x 225 section 65 8 40 600 x 450 x 300 section 85 6 40 600 x 450 x 100 frame 45 8 100 600 x 450 x 55 lid 50 16 55 750 x 600 x 150 section 60 6 55 750 x 600 x 250 section 100 4 55 750 x 600 x 70 cover slab (600x450 access) 75 8 70* 1000 x 675 x 150 section 94 6 60 1000 x 675 x 250 section 130 4 60 1000 x 675 x 76 cover slab (600x450 access) 130 8 75* 1200 x 750 x 150 section 120 6 75 1200 x 750 x 250 section 200 4 75 1200 x 750 x 80 cover slab (600x600 access) 185 6 80*

Chamber Size Cover

600x450 Frame and Lid places straight on top of unit750x600 Below surface slab with 600x450 access, allowing use of Frame and Lid

1000x675 Below surface slab with 600x450 access, allowing use of Frame and Lid1200x750 Light or Heavy duty below surface clab with 600x600 access, allowing use of standard steel access hole cover

FP McCann’s frame (also known as a surround) and lid combination are designed to sit flush with the top course such as tarmac or concrete surfacing, or in grassy areas.

The lid itself features an anti-slip chequered finished and recessed lifting points to allow removal from the frame by use of standard lifting eyes.

To complete the chamber, FP McCann have a range of covers and ground level components:

Drainage

ChamberSections

Slab

Page 33: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P32

Gullies

Gully Cover Slabs The Gully Cover Slab is designed as seating for a gully grate

Benefits of the Gully The seal has been cast in, thus preventing loss or

damage on site An integral seal and rodding eye for universal

sealing characteristics The rodding eye closure has been recessed into the

concrete to help eliminate dislodging Reduced thickness giving reduced weight and a

smaller footprint, for better vehicle utilisation

Improved system that helps prevent any discharge of oil

The Gully is fully universal suiting all plastic and clay drainage products from 160mm to 186mm diameter

Does not lose shape Does not float (self weight inhibits flotation)

Quicker to lay ensuring reduced labour costs Use on top of 450mm diameter gully Eliminates laying engineering bricks on site Sits flush to kerb for enhanced stability 100mm thick single piece unit

Eliminates brickwork vertical joint ‘weakspots’ Greater stability than brickwork Quality product produced by vibration process Compressive strength similar to Class B.Eng. bricks

375 750 150 180 51 66 375 900 150 200 67 66 450 750 150 215 71 60 450 900 150 255 95 60 450 1050 150 270 118 60 450 1200 150 280 142 60

Diameter Depth Outlet Internal

Nom

inal

W

eight

(kg)

Appr

ox.

Capa

city (

litres

)

No P

er Lo

adDimensions (mm)

Standard Horseshoe Length 750 600 Width 650 650 Thickness 100 100 Weight 70kg 58kg Hole Size 450 450 Qty/Pack 12 12

Standard Gully Cover Horseshoe Gully Cover

Benefits of the Gully Cover Slabs

Gullies & Slabs Range

Drainage

Note: Gullies and Gully cover slabs manufactured in accordance with BS 5911-6

Page 34: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P33

Pipes should only be connected to the Easi-Pit using an FP McCann approved lubricant

CatchpitCatchpitThe catchpit e"ectively provides a sealed sump manhole, a monolithic precast concrete unit #tted with connector seals which can be used to connect to the following types of pipe: uPVC, twinwall, clay, ductile iron and concrete. The catchpit is designed to accommodate pipe sizes DN150 to DN450. The catchpit is designed in line with highway speci#cation.FP McCann can produce catchpits upto DN375 in a straight through orientation (180 degrees). 4-way units with orientations at 90 degrees can be produced upto DN300 only; beyond DN300 4-way orientations are not available. DN450 inlets must be cored onsite.

Benefits of using the Catchpit unit Creates an immediate watertight structure Cost bene#ts with reduction in construction time and resource requirement Economically advantageous as limited wet trades are required in the manhole

construction Accommodates connection to all types of pipe used in road and manhole

construction Safety bene#ts gained in the construction of manholes as the pre-formed sump

and connector seals eliminate on site construction, thus greatly reducing labour activity within the manhole

Increased con#dence to meet industry standards Quality is greatly increased as construction is within the factory environment Eliminates material wastage associated with current in-situ method

material removed from site

Easi-Pit weight 1.38tonnes.

Catchpit Dimensions

DN150mm - DN450mm

Drain Hole (80mm O.D.)to accommodate 65mm nominal bore pipe

Invert Level 300mm

DN45mm (x3)

Easi-Base is a kitemark product,

manufactured and testedto BSEN1917:2002

Note: Standard unit will have an invert level of 300mm for inlet and outlet pipes. If a non-standard invert level is required, please specify when ordering.

WARNING When Lifting !45°Inclined pull only

Drainage

Page 35: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P34DN 1050 Highway’s Agency Catchpit

Drainage

Precast concrete catchpits with the new $exible rubber pipe connector seals can be utilised every 100 metres on a single lane carriageway, replacing the requirement to cast a base sump in situ and construct the catchpit from a standard DN1050 manhole ring.

The innovative EPDM 40 $exible rubber seal at the connection points can accommodate pipe sizes DN150 to DN 300, including DN225. This negates the need to saw cut openings in the concrete wall and the use of wet mortar trades to seal the pipe surround.

Catchpits are supplied with factory #tted pre-marked EPDM 40 rubber blanks. The unique rubber blank/seal has pre-formed cutting grooves around the three DN entry sizes indicated. This allows for accurate cutting out to pipe diameter requirement. There is no similar system available in the market. Once pipes are #tted into the seal, up to 45 degrees of pipe de$ection is permitted without breaking the seal.

Highways Agency Compliant EPDM flexible seal DN1050 CatchPit

The signi#cant savings are in time, eliminating the need for follow-up #nishing gangs. Added safety bene#ts are keeping operative time in the excavation to a minimum and no power tools are required to cut concrete. Indirect cost bene#ts are as a result of saving up to 26 hours of time related to curing of wet trades on a traditional build.

Requirements for catch pits are as speci#ed in the MCHW 500 Series Clauses and MCHW 3: F Series Drawings. The MCHW clauses call for the catch pit to be in compliance with BS EN 1917 and BS5911. FP McCann catchpit products are manufactured under BSI Kitemark approval to comply with BS EN 1917 and BS 5911 and are therefore fully compliant to HA speci#cation.

Can be used in straight through, 90° connection or straight through with a cross drain.

Once pipe is fitted to the connector, up to 45° of deflection is possible without breaking the seal.

Page 36: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P35

Note: Headwalls have a 2 or 3 point lifting system incorporated. FP Mcann supply all lifters with product at no additional cost. Invert levels are variable subject to customer requirement. PDF and AutoCAD drawings available to download.

Headwall Range

Accomodates Pipe Sizes

Max Pipe O.D. mm

Back wall height

(external) mm

Front wall height

(external) mm

Width at back wall (internal)

mm

Width at front wall (internal)

mm

Head-wall

Length (mm)

Standard Invert level

(Variable)

Wall Thick-ness (mm)

Floor Thick-ness (mm)

Approx. Weight

(Kg)

* HW Extra Large

1050, 1200,1350, 1500 1830 2410 650 2020 2850 2060 80 250 250

Part A 4750Part B 4750

HWLarge 200

900, 825, 750, 675, 600, 525 1080 1420 500 1220 1950 2150 100 200 162 4105

HWLarge 100

900, 825, 750, 675, 600, 525 1080 1420 500 1220 1950 2050 100 100 162 2766

HWMedium

150450, 375, 300 590 1150 500 700 1550 1370 100 150 162 1640

HWMedium

100450, 375, 300 590 1150 500 700 1550 1320 100 100 162 1235

HW Small 150 300, 225, 160 430 810 300 520 1300 1320 100 150 162 1213

HW Small 100 300, 225, 160 430 810 300 520 1300 1320 100 100 162 1090

FP McCann manufactures a range of headwalls designed to connect pipe work discharging into open water courses.Advantages

Prefabricated o"-siteSpeedy and e%cient to install (minimising on-site labour)In cases where limited installation time is given due to tides etc.Cost e"ective solutionNo on-site shuttering requiredComplete with 2 or 3 lifting hooksNo part-load charges for concreteFlap valves and grids available

Headwalls

Note:Wall Thickness is directly proportional to the approximate weights

WARNING When Lifting !45°Inclined pull only

Drainage

Note: * Extra large headwall is manufactured in 2 parts, dimensions provided represent completed unit. Weir walls and other special #nishes can be added to any of the headwalls as part of a bespoke design package. Headwalls are available with handrails and precast steps

Page 37: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P36Easi-Flow ChamberThe FP McCann Easi-Flow chamber combines an integral base and side walls with provision for inlet and outlet connections. It can be used in a number of applications, including:

As a silt-trap As a valve chamber As a flow rate controller (requires installation of a vortex valve unit, sold separately)

Sizes availableEasi-Flow chambers are available between DN1200 - DN2400. Bespoke larger units can be manufactured to client specification.

Flow rate controlFP McCann can offer supply of a Hydro-Valve vortex flow control device. The Hydro-Valve is designed to limit storm water outflow to a specific discharge rate. Sizes are available between 1 – 80 l/s depending on head height. The unit is self activating with no need for an external power source and comes with a certified flow rate.The Hydro-Valve is a device for controlling storm water flow by hydraulic effect without requiring moving parts. At low flow rates, water entering through the inlet passes through the vortex chamber to the outlet with no restriction. As flow rate increases water enters through the inlet with enough energy to create a vortex in the vortex chamber which results in a considerable pressure drop between the inlet and the outlet restricting the flow to the allowable discharge. The Hydro-Valve therefore operates automatically with no moving parts and no external power source. A typical application of this valve is to control the flow from storm water attenuation tanks preventing downstream flooding during periods of heavy rainfall.The Hydro-Valves are custom designed to achieve a specified design flow rate at a given head height. They are manufactured under an ISO 9001 quality assurance system and are available in sizes compatible with the FP McCann Easi-Flow chamber range.

Hydro-Valve - Customised Specification No moving parts Self activating Self cleansing Manual by-pass Easy installation 3-6 times greater orifice CSA Hydraulic data available

For more information on Hydro-Valves contact a member of FP McCann technical sales.

*FP McCann advise not to complete the manhole construction until the JFC flow control device has been positioned correctly inside.

Drainage

Page 38: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P37Valve Chamber

Drainage

FP McCann design and manufacture a bespoke range of reinforced valve chambers capable of housing any size and type of valve/pump. Valve chambers consist of a precast concrete sealed sump manhole with factory fitted saddles to house the pump and are used in the management of water, oils and chemicals.

Benefits Immediate watertight structure

Reduced installation time/costs

Accommodates connection to all types of pipe including concrete, metallic, HDPE and clay

Pump is raised of the ground and sits on preformed concrete stool

Easy and clean access for operation and inspection

Chamber Diameter 1200 - 3000mmChamber Height 900mmStool Bespoke to project requirementsPipe Size 150 - 375mmInlets / Outlets Will vary to accommodate pipe sizeCover Slab Thickness Will vary in accordance with chamber diameterBase Thickness 250mm

Page 39: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P38

SummaryA system that gives the user benefits of a durable plastic encapsulated ladder without the need to specify an exact length or fit on site. In addition a single specification can be used for all depths of access.

Product SpecificationsBSEN 13101 Plastic Encapsulated StepsWIS 4-33-01: 1990 Polypropylene Encapsulated Steps

ApplicationsConcrete manholes and inspection chambers.Renovation of existing structures.

Materials High Impact Virgin Polypropylene copolymer plastic, yellow as high standard colour. If the ladder is to be subject to prolonged exposure to daylight then black or uv stabilised material should be specified. Structural steel reinforcement as standard.

PerformancePull out load: 7.5kN minimum when fitted in accordance with manufacturers instructions.Deflection under load: 5mm maximum at 2.5kNPermanent Set: 0 mm at 2.5kNImpact: 20kg weight from 1metre, no cracking.Chemical Resistance: At least pH2 to 12Integrity of plastic: 2M ohm at 500 volts DCThickness of plastic: 3mm minimumMinimum cross section: 25mm diameter

Advantages1. Excellent Corrosion Resistance2. Visibility3. No Sharp Edges4. Eliminates need to specify exact length or fit on site.5. Steel reinforcement gives predictable deflection under load without

causing brittle failure.

Plastic EncapsulatedLadders & Rungs

Drainage

Page 40: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P39

SummaryThe handhold entry pole system is suitable for aiding maintenance engineers in the initial entry into a manhole from the surface level. Once fitted, the entry pole is a permanent fitting in the manhole which is stored in the lowered position beneath the level of the cover. When required, the entry pole can be easily extended by simply hooking the easy to reach loop located at the top of the pole, pulling the handle upwards and twist locking into position. The handhold then provides a stable support to aid the entrance of the manhole as well as a clear visual indication of the location of the manhole when open. This helps prevent injury of other people in the area. Once the engineer has used the entry pole to aid their return to the surface, the pole is simply twisted to unlock it from the raised position and lowered back into the manhole ready for the next time it is needed.

SpecificationThe handhold has a pole length of 1200mm and can be assembled to give three different distances from the pole to the wall. This is designed to accommodate different cover positions.

Advantages Helps the user find the first step safely Creates visual aid to indicate location of manhole to other people in the areaEasy to fit Easy to raise and lower High strength for ultimate safety Low cost Can be fitted to any Caswick step Two projections for round or flat walled manholes

Handhold & Entry Pole System

Drainage

Page 41: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P40

FP McCann manufacture box culvert sections to customer specifications. By taking an individual approach to each job, we ensure that each unit supplied is engineered to the exact design criteria.

Based centrally at our Telford factory, we can deliver throughout the UK.

Culverts have a variety of different applications from the routing of water courses to providing safe pedestrian and animal crossings under road and rail infrastructure.

Uses include:

Attenuation and Storage Tanks Water Course Diversion Open Channels Road Crossings Pedestrian, Animal and Agricultural Subways Shafts Conveyor Protection Service Tunnels and Ducts

End walls, access points, vent holes, inlets, outlets, rungs, angles and splayed ends can all be added to any run of culvert. Starter bars and sockets can also be included for further casting on site.

Box Culverts

Page 42: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P41Box Culverts

TYPICAL CULVERT:Internal span and height from 5400mm and 500mm in lengths up to 2200mm (dependant on the culvert profile and span sizes)

CHANNELS:Half round (or equivalent) channels can be cast into the floor of the units at any position with a choice of diameters

BENCHING:Combined with either a channel or cast as a ‘vee’, benching improves flow rates

MAMMAL LEDGES:Cast in mammal ledges allow access through the culvert to wildlife without the requirement for extra site provisions

DUAL-CELL:Two water courses cast into a single unit

SPECIALS:Bespoke units accommodating a variety of features can be manufactured to the customer’s design requirements

FP McCann’s experienced engineers and detailing team together with a modern manufacturing facility at Telford, Shropshire, have the flexibility to quickly respond to meet any design criteria and deliver nationally to just-in-time requirements.

Supplied in either single or multiple runs, the use of precast concrete box sections in civil engineering projects is wide ranging, from their use for directing watercourses to the provision of attenuation tanks and underpasses.

Page 43: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P42

FP McCann storm water management systems can be designed to suit a wide range of construction projects and drainage schemes. Precast concrete attenuation components include products such as side entry manholes, stop end bends and spigot and socket end wall pipes. These products can either be engineered into an on-line sewer pipe system or utilised off-line as single or multiple storm water holding tanks.All FP McCann storm attenuation products comply with the requirements set out within Sewers for Adoption 7th Edition and are made from Kite marked precast concrete components which comply with the relevant Standards. Pipes BS EN 1916 & BS 5911-1 and Manholes BS EN 1917 & BS 5911-1.

Examples

Spigot and Socket Tank End Wall Pipes (Adaptor/Fitting - BS EN 1916:2002)

wall. Inlet/outlet holes are generally cored into the wall

Side Entry Manholes (Junction - BS EN 1916:2002)

build is not possible

be fitted if required

height

Stop End Bends (Bend - BS EN 1916:2002)

height

Side Entry Manhole with Bend (Junction/Bend -BS EN 1916:2002)

Storm Water Management

Water Management

Page 44: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P43Storm Water Management

Water Management

Mid Entry Manholes (Junction/Bend BS EN 1916:2002)

End Entry Manholes (Junction - BS EN 1916:2002)

Key Benefits and Advantages of FP McCann Storm Management Systems 1. Flexibility of design - Adaption’s to meet client specification 2. Products can be used in space restrictive on-line sewer systems providing the required storage volume. 3. Reduction in construction times 4. Quality assured and kite marked products used 5. Sustainable systems with design life in excess of 100 years 6. Site safety benefits related to reduction of man hours spent in excavation 7. Ease of access for maintenance 8. Can be linked to other SUDS related systems such as rainwater capture and re-use

Note FP McCann Storm Attenuation units are not designed as load bearing structures and should be protected by a suitable design mix 150mm concrete surround with minimum 300mm to support the shaft joint.

Page 45: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P44

The production of water impermeable surfaces in construction is inevitable. This includes roof areas on buildings, car parks, loading bays and road pavements. The provisions of these surfaces interrupts the natural drainage process, creating increased stormwater runoff in respect of both volume and flow rate.In many cases this increase in stormwater flow and volume is a problem as the local sewer or watercourse does not have the sufficient capacity to cope. This problem could be alleviated by an increase in the size of the stormwater sewer or watercourse, thus providing the capacity within the drainage system to cope with the increased surface water. This however may be expensive, cause major infrastructure disruption, and may often be completely unfeasible.Legislation under Planning Policy Statement 25 and Building Regulations approved Document H3 for flood risk assessment (SUDS), has created the need for planners and developers to design and install effective storm water management systems.The types of system that can be employed to overcome these issues are well documented and varied. Quite often, they can be very technically demanding in their operation, maintenance and construction. The selection of a system will depend on site constraints, position, expected loading, geographical limitations and inevitably cost.The Easi-Storm system offers a complete solution to the stormwater attenuation problem and utilises a tried, tested and approved method of stormwater storage. F P McCann can provide the complete package of design, product specification, supply of products, and advice with installation.

Features:· Available in a range of sizes· Can use and combine a number of techniques and products such as

pipes, culverts, tanks, manifold systems and soakaways· A complete solution with all connections· Established and familiar products· Can be laid in short lengths· The system can be adapted to load bearing and non-load bearing applications

· 120 year design life· Adoptable by water companies· Manufactured in accordance with a BSI accredited quality management

system conforming to BS EN ISO 9001· Available straight from stock

Benefits:· System can be designed specifically to suit the application· Speedy construction using a standard joint· No need for fabrication on site or external specialist contractors· Straightforward installation using known techniques – no need to

retrain

Easi - Storm Attenuation Systems

90 degree endcap with maintanceaccess to specificcover level

Inlet pipes in various diameters and positions for multipile connections

Pipes can be supplied with strengths to BS 5911 depending on the loading situation, thus keeping bedding and installed costs down

Pipes in various diameters to suit storage required and site constraints

Sectional construction negates the need for large open excavations

Flow control chamber with cast in sump and vortex flow control device

Water Management

· Can be installed under roads and car parks· Can cope with construction plant loading· Flotation is not a concern – no need for geotechnical anchors when

located below the water table· Long term solution

Design:The design of the system can be tailored to suit most structural and hydraulic criteria.

Structural:The inherent structural strength of concrete is well documented and can be designed to meet the severest of loading criteria. Easi- storm systems can be tailored to suit low load situations when the tank is to be situated below verges or gardens.

Relevant Legislation/ Information:· Planning Policy Statement 25 (PPS25) December 2006. Department of

Communities and Local Government (DCLG)· Building Regulations. Department of Communities and Local

Government (DCLG)· Future Water February 2008. Department for Environment, Food and

Rural Affairs (DEFRA)· The Pitt Review, Learning Lessons from the 2007 floods. Sir Michael Pitt.

· The Code for Sustainable Homes February 2008 Department for Communities and Local Government (DCLG)

· The SUDS Manual 2007 CIRIA C697· Sustainable drainage systems - Hydraulic, structural and water quality

advice 2004 CIRIA C609.· Flood and Water Management Act 2010

An example of an effective Easi-Storm system

Page 46: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P45

Water Management

IntroductionFP McCann have designed and developed a new range of Hydrodynamic Separators for the treatment of urban catchment storm-water runoff. The Easi-Hydro Separator provides a cost effective solution for designers, engineers and contractors involved in the provision of sustainable urban drainage systems. The Easi-Hydro Separator has no moving parts, requires no power and is constructed in precast reinforced concrete. All internal components are manufactured in GRP and stainless steel ensuring long asset life.

The Easi-Hydro Separator has been independently tested by WRc and total solids removal rates have been measured ranging from 85 to 92%. The Easi-Hydro Separator is also effective in the removal of hydrocarbons, litter and other storm-water debris.

OperationThe Easi-Hydro Separator is specifically designed to remove suspended solids, hydrocarbons and floatable debris from the storm-water runoff. The Easi-Hydro Separator chamber is constructed in precast reinforced concrete and supplied complete with a unique, factory installed, GRP flow management module. This unique design produces low energy vortex flow patterns allowing the solids to settle to the bottom of the treatment chamber for subsequent removal. Re-suspension of the solids is minimised by provision of a GRP baffle plate positioned above the solids storage sump. Floatable debris is retained within the Easi- Hydro Separator and prevented from discharging by a dip outlet pipe and launder channel arrangement.

Flows to treatment are controlled by a specially designed launder channel and inlet pipe arrangement. Flows in excess of the maximum treatment flow overflow a weir, bypass the treatment zone and directly discharge through the outlet pipe. This helps to minimize the effects of scour within the treatment compartment and optimises the performance of the unique Easi-Hydro Separator.

Easi-Hydro Separator

Easi-Hydro Separator

Page 47: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P46

Water Management

Easi-Hydro SeparatorApplications

Housing developmentsRetail parksCommercial centresLeisure facilitiesIndustrial developmentsHighway drainage projects Car parksExisting surface water sewer dischargesSustainable Urban Drainage Schemes

Selection Chart

PRE EHS/1050 PRE EHS/1200 PRE EHS/1500 PRE EHS/1800 PRE EHS/2100

1050 1200 1500 1800 2100

15 25 35 50 75

25 35 50 100 150

&225 &300 &375 &450 &525

&225 &300 &375 &450 &525

3 0.75 0.85 2.50 3.00 3.2

Inletoutlet

WRc test results are available on request.

Page 48: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P47Easi-Rain Harvesting Chambers

Easi-Rain by FP McCann is a bespoke range of precast water storage chambers that are compatible with water harvesting systems for residential, industrial / commercial and agricultural installations. Capturing rainwater for re-use offers significant cost savings for the user and benefits the environment by increasing water resources and further enhancing water amenity. Easi-Rain complies with Environment Agency SUDS (Sustainable Urban Drainage System) directives.

The basic concept of harvesting rainwater is simple - rainwater is mostly collected from the roofs of buildings - it flows by gravity through gutters and downspouts and is then filtered and collected by a storage tank. From the tank it can be recirculated or treated to produce a better quality of recycled water.

Internal Diameter (x1000mm) Litres Weight

kgDN1800 1200 1800DN1800 1500 1900DN2400 3000 5900DN2400 5000 7250DN2400 7000 8700

Volume Capacity of Storage Chambers

Water Management

Page 49: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P48Shafts & TunnelsThe McCann range of shaft and tunnel products have been developed to meet the requirements of the latest industry standards which include the British Tunnelling Society Specification and the Civil Engineering Specification for the Water Industry. Designed with consideration to the ease of construction and speed of installation, the McCann shaft and tunnelling systems offer strength, stability and overall performance in all types of ground conditions.Shaft and tunnel products are manufactured in accordance with FP McCann’s quality management system, BSI accredited to BS EN 9001.

Products manufactured include:

Smoothbore Shaft and Tunnel Segments

Cover and Landing Slabs

Caisson Shaft Units

Jacking Pipes

Page 50: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P49Smoothbore Shaft andTunnel Segments

FP McCann has launched and is developing a comprehensive range of smoothbore shaft and tunnel linings. Each size is specifically designed to meet the tunnelling industry’s exacting and varied needs, recognising the key criteria as being strength, stability and the capability of performing in all types of ground conditions.

Design Features:All rings, with the exception of the cutter choker comprise of ordinary segments and two top segments. The top segments have one tapered cross joint in order that they can be installed with EPDM gasket. The cutter choker comprises all ordinary segments.

Sealing:All segmental rings are supplied with a factory fitted EPDM gasket as the primary sealing system that is immediate upon build.

Connection:Cross joint connections are made using a spear bolt passing through a pocket in one segment and a plastic socket in the adjacent segment. Circle joint connections are made using a T bolt passing through a hole in one segment and into a T box in the adjacent segment. Bolts are designed to fully compress the gasket. All connections are sheradised. (Other finishes to fittings, including galvanised, are available on request).

Ring Types:Segmental ring types provided by FP McCann:Segmental rings in stock are front or back bolted.

1. Standard rings 2. Corbel rings 3. Recessed rings (standard, choker or cutter choker) 4. Choker rings 5. Combined cutter choker rings

Mix and reinforcement:Each segment is wet cast to achieve a smooth internal finish. The concrete mix provides a Design Chemical Class 4 (DC4) with a minimum 28 day characteristic strength of 55 N/mm2. Alternative mixes are available. The segments are reinforced with either a reinforcing cage or structural synthetic and steel fibres to suit both design and customer requirements.

Build Methods:The segmental rings are suitable for underpinning, caisson and chimney construction methods.

Page 51: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P50

Quality: F P McCann conducts all operations using an Integrated Management System accredited to BS EN ISO 9001.

Key Features and Benefits:Smooth internal facesSimple locking processSpeedy installationCost reducingAdded safety featuresTechnical advice and support

McCann Smoothbore Shaft LiningsSize (Standard ring) Segments

per ring(Std ring)

Vol perring

(Std ring)(m!)

Wt per Standard

ring*(tonnes)

Standardsegmentweight*

(Kg)

Corbelsegmentweight*

(Kg)

Chokersegmentweight*

(Kg)

Cutter /chokerseg wt*

(Kg)

Excavations m! perstandard ring Grout

perring(m')

Caulking

Internaldiameter

(m)

Externaldiameter

(m)

Width(m)

mm over extrados Circle(lin m)

Cross(lin m)Ord Top 0 25 50

3.660 4.060 1.00 4 2 2.43 6.06 1011 1140 1280 1345 12.95 13.27 13.59 12.75 11.58 6.00

4.500 4.900 1.00 5 2 2.95 7.38 1055 1194 1332 1400 18.86 19.24 19.63 15.39 14.22 7.00

5.000 5.400 1.00 6 2 3.27 8.17 1021 1156 1289 1354 22.90 23.33 23.76 16.96 15.79 8.00

5.500 5.900 1.00 6 2 3.58 8.95 1119 1411 27.34 27.81 28.27 18.54 17.36 8.00

6.000 6.450 1.00 7 2 4.40 11.00 1222 1369 1506 32.67 33.18 33.70 20.26 18.93 9.00

7.500 7.950 1.00 9 2 5.46 13.65 1241 1416 1527 1605 49.64 50.27 50.90 24.98 23.64 11.00

8.200 8.700 1.00 10 2 6.64 16.59 1383 1559 1669 1757 59.45 60.13 60.82 27.33 25.84 12.00

9.000 9.500 1.00 10 2 7.26 18.16 1514 1826 70.88 71.63 72.38 29.85 28.35 12.00

10.500 11.100 1.00 12 2 10.18 25.45 1818 2130 2284 96.77 97.64 98.52 34.87 33.07 14.00

12.500 13.200 1.00 12 2 14.13 35.32 2523 2895 136.85 137.89 138.93 41.47 39.35 14.00

15.000 15.700 1.00 14 2 16.88 42.20 2637 3024 193.59 194.83 196.07 49.32 47.20 16.00

20.000 20.900 1.00 18 2 28.91 72.28 3614 4025 343.07 344.71 346.36 65.66 62.91 20.00

25.000 25.900 1.00 22 2 35.98 89.95 3748 4172 526.85 528.89 530.93 81.37 78.62 24.00

*Nominal weights. Increase by 5% for sizing of lifting equipment and reduce by 5% for floatation design.Sizes in italic are future development

Smoothbore Shaft and Tunnel Segments

Page 52: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P51Smoothbore Shaft and Tunnel Segments

FP McCann design and manufacture a bespoke range of both Trapezoidal and Expanded Segmental Smoothbore tunnel linings, designed to provide durability, speed and ease of installation in tunnel construction. Trapezoidal tunnel linings are developed to work alongside technologically advanced tunnel boring machines, with linings designed and manufactured to suit exacting project requirements.

Tunnel segments can be modified to suit a variety of joint fixings, segment thickness and tunnel diameter’s. The latest manufacturing techniques incorporate steel fibre dosing to guarantee a high quality, reliable product. The wedge shape design of individual segments eliminates the requirement for a special closure segment.

Trapezoidal Segment

Expanded Lining

Page 53: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P52Smoothbore Shaft and Tunnel Segments

Trapezoidal Tunnel Linings

Expanded Tunnel Linings

Size Segments per ringVol per

ring(m3)

Weight perring*

(tonnes)Internal

diameter(m)

External diameter

(m)

Ring Width

(m)Ord Top Key

2.590 2.950 1.000 5 2 1 1.57 3.92

3.050 3.400 1.200 5 2 1 2.13 5.32

*Nominal weights increase by 5% for sizing of lifting equipment and reduce by 5% for flotation design.

*Nominal weights increase by 5% for sizing of lifting equipment and reduce by 5% for flotation design.

Size

Segmentsper ring

Vol perring(m3)

Wt perring*

(tonnes)

Maximun piece

weight*(kg)

Bolts per ring (number x dia x

length mm)Internal

diameter(m)

Externaldiameter

(m)

Max Ring Width

(m) Min Ring

Width(m)

2.850 3.200 1.010 0.99 6 1.66 4.32 698 TBC

3.050 3.400 1.211 1.189 6 2.13 5.32 893 24 x M18 x 260 Spear Bolts

Page 54: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P53

Shaft Cover and Landing SlabsReinforced Shaft Cover and Landing Slabs are an integral part of FP McCann’s shafts and tunnels product range, manufactured at the Company’s specialist precast concrete facility in Cadeby.Both cover and landing slabs are cast to design specifications and made to order for ‘just in time’ delivery. On site, the slabs can be quickly installed and provide an integral secure shaft cover or internal landing.

SizesCover and Landing slabs are generally circular to match the McCann range of smoothbore shaft segments and other segmental linings. They are available in 1, 2, 3 and 4+ sections. The standard size range is highlighted below. A bespoke design facility is available for non-standard shapes and sizes.

Standard Slab Dimensions

Shaft Cover and Landing Slabs

One piece Cover Slabs

Shaft internaldiameter (mm)

Shaft externaldiameter (mm)

Slab thickness (mm)

Total slabweight (T)

2100 2350 250 2.82

2400 2680 275 4.03

2700 3000 275 5.05

3000 3360 300 6.92

3660 4060 325 10.94

Two piece Cover Slabs

Shaft internaldiameter (mm)

Shaft externaldiameter (mm)

Slab thickness (mm)

Total slabweight (T)

3000 3360 300 6.92

3660 4060 325 10.94

4000 4400 350 13.84

4500 4900 375 18.39

5000 5400 400 23.82

Three piece Cover Slabs

Shaft internaldiameter (mm)

Shaft externaldiameter (mm)

Slab thickness (mm)

Total slabweight (T)

5000 5400 400 23.82

5500 5900 425 30.21

Four + piece Cover Slabs

Shaft internaldiameter (mm)

Shaft externaldiameter (mm)

Slab thickness (mm)

Total slabweight (T)

5500 5900 425 30.21

6000 6450 450 38.23

6500 6950 475 46.85

7500 7950 525 67.76

8000 8500 550 81.15

9000 9500 600 110.58

10500 11100 675 169.83

12500 13200 775 275.75

Cover Slabs with RC Beams

Shaft internaldiameter (mm)

Shaft externaldiameter (mm)

Slab thickness (mm)

Number ofRC beams

8000 8500 250 2

9000 9500 250 2

10500 11100 275 2

12500 13200 350 to 250 2, 3 or 4

15000 15700 400 to 300 2, 3 or 4

Cover Slabs with RC Beam or Pre-stressed Beams

Shaft internaldiameter (mm)

Shaft externaldiameter (mm)

Slab thickness (mm)

Number ofRC beams

20000 20900 Special Special

25000 25900 Special Special

One piece Landing Slabs

Shaft internaldiameter (mm)

Slabdiameter (mm)

Slab thickness (mm)

Total slabweight (T)

2100 2050 175 1.50

2400 2350 175 1.97

2700 2650 200 2.87

3000 2950 200 3.55

Two piece Landing Slabs

Shaft internaldiameter (mm)

Slabdiameter (mm)

Slab thickness (mm)

Total slabweight (T)

3000 2950 200 3.55

3660 3610 225 5.99

4000 3950 250 7.97

4500 4450 275 11.12

5000 4950 300 15.01

5500 5450 325 19.71

6000 5950 350 25.30

Three + piece Landing Slabs

Shaft internaldiameter (mm)

Slabdiameter (mm)

Slab thickness (mm)

Total slabweight (T)

6000 5950 350 25.30

6500 6450 375 31.86

7500 7450 425 48.17

8000 7950 450 58.08

9000 8950 500 81.79

Page 55: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P54

Mix and reinforcementSlab sections are wet cast in fabricated steel moulds and steel cage reinforced. The concrete mix design is to a standard characteristic strength of 55N/mm2 at 28 days. Alternative mixes are available.

Design FeaturesDesign and detailing may be undertaken by FP McCann or to the customers design specification. Reinforced concrete cover slabs are generally designed to withstand loads in accordance with the recommendations of British Standard 5400:Part 2 & BD37/01, generally 30 units of Type HB loading, together with the load assoicated with overburden. Cover slabs can be designed to withstand 45 units of Type HB loading, or loading specific to contract. In non-trafficked areas, the slabs may be designed for notional superimposed loads. Landing slabs are designed to an imposed load of 5kN/m2.

Lifting and HandlingDepending on lifting requirements on site, FP McCann are able to supply fitted lifting loops or cast in sockets and spherical head lifting anchors.

Quality standardsShaft Cover Slabs and Landing Slabs are manufactured in accordance with FP McCann’s quality management system, BSI accredited to BS EN 9001.

Key Features and BenefitsNo formwork or ready mixed concrete requiredSimple jointing systemSpeedy installationBespoke design and casting serviceTechnical advice and support

Shaft Cover and Landing Slabs

Page 56: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P55

FP McCann Caisson Range

Caissons Shafts DN Available Depths (mm) Barrel DN Wall Thickness Lifting Hole

mm 1000 750 500 mm mm Qty per unit

2100 ( ( ( 2350 125 3 No. RD24 Wavy Tail Inserts

2400 ( ( ( 2680 140 3 No. RD30 Wavy Tail Inserts

2700 ( ( ( 3000 150 3 No. RD30 Wavy Tail Inserts

3000 ( ( ( 3360 180 3 No. RD30 Wavy Tail Inserts

3600 ( ( ( 3970 185 3 No. RD30 Wavy Tail Inserts

4000* ( ( X 4400 200 4 No. RD36 Wavy Tail Inserts

*DN4000 supplied as a two piece unit.

FP McCann manufactures a range of reinforcing units suitable for sinking by the caisson method. Caisson shaft units can be supplied with diameters of 2100mm up to 4000mm. Caissons are manufactured in accordance with the requirements of BS EN 1917, and have Kitemark certification where relevant to the scope of BS5911 (2100mm – 3000mm diameters). However 3600mm and 4000mm diameters remain operative within the scope of the ISO9001 accredited Quality Management System.

Open caisson-sinking techniques permit a shaft structure to be progressively sunk, either under its own weight or with the aid of caisson jacks, in a controlled manner from the surface to a predetermined depth. Caisson shafts are constructed using a metal cutter ring and base section with rings being added on top as excavation proceeds. The technique is suited to shaft construction through weak soils, high-plasticity clays, silts, sands and gravels; particularly below the water table.

Caisson Units

Page 57: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P56

Caisson Rings – Table of Weights (DN 2100-4000)

Caissons Shafts DN Cutting Shoe Weight (Kg) Approx. Weight p/meter Caisson

(with cutting shoe) (Kg)**Approx. Weight p/meter Caisson

(without cutting shoe)**mm 10mm 20mm 10mm 20mm Kg

2100 320 581 2590 2851 22702400 378 635 3278 3535 29002700 441 794 3931 4284 34903000 529 953 5209 5633 46803600 641 1148 6061 6568 5420

* 4000 725 1298 7585 8158 6860

* DN4000 supplied as a two piece unit.

** Nominal weights increase by 5% for sizing lifting equipment and reduce by 5% for floatation design.

Base units may be fitted with a light duty (10mm) or a medium duty (20mm) cutting shoe.

Caisson Units

Page 58: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P57Jacking Pipes

DN* mm

Bore Diameter

Amm

Wall Thicknesss

Bmm

Outside Diameter

Cmm

Int. Diamm

Length Metres

Weight Kg approx

Spigot Length

Dmm

Socket Length

Emm

Recess (lead pipe

only)F

mm

Packer SizeWidth

mmThickness

mm# 450 450 77 604 480 1.2 430 115 110 - 33 12

# 600 585 90 764 611 1.2 640 125 110 - 46 15

# 600 585 90 764 611 2.0 1050 125 110 - 46 15

900 904 98 1100 934 2.5 2120 130 125 1060 56 15

1000 980 110 1200 1010 2.5 2580 130 125 1160 66 15

1200 1200 115 1430 1230 1.2 1590 130 125 1390 68 18

1200 1200 115 1430 1230 2.5 3250 130 125 1390 68 18

1400 1350 125 1600 1380 2.5 3950 130 125 1560 78 18

1500 1500 140 1780 1530 2.5 4910 130 125 1740 93 18

1800 1830 155 2140 1860 2.47 6490 134 125 2100 110 18

2000 1950 190 2330 1980 2.35 8150 134 125 2290 145 18

2000 1950 190 2330 1980 2.5 8600 134 125 2290 145 18

2000 1980 175 2330 2010 2.5 8040 134 125 2290 130 18

2000 2076 167 2410 2106 2.47 7900 134 125 2370 122 18

2400 2425 200 2825 2455 2.5 11190 145 140 2785 150 18

Alternative length of pipes (maximum length 2.5m)Alterative length of pipes in some of the sizes shown above can be manufactured to order.FP McCann is always interested in adding to the above range, and would be pleased to discuss the supply of any sizes not shown.

* Nominal size as given by Table 6 BS 5911-1.# These items are not covered by BSEN 1916 and BS 5911 - 1 but have been designed and tested using the same criteria. Weights given are the nominal weights increased by 5% to allow for variations in materials unit tolerance.

FP McCann Jacking Pipes enable pipe installation where the opening of trenches is neither practical nor cost effective.

They provide an environmentally suitable solutionFP McCann jacking pipes are made from dense, durable, steel cage reinforced, sulphate resistant concrete having a minimum strength of 50N/mm2

They are manufactured in accordance with BSEN 1916 and BS 5911-1 and certified by Quality Assessment under the Kitemark Scheme and BS EN ISO 9001 Features of FP McCann jacking products include

- self-lubricating joint gasket (Lamell type F-146) - built-in handling system with an extensive range to suit most machines and

shields FP McCann is a member of the Pipe Jacking Association

Page 59: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P58

Infrastructure & Power

Power Infrastructure Cable Ducting Systems

FP McCann offers a specialist range of precast reinforced concrete cable troughs and ducting systems used to house and protect most types of services, including power and communication cables and pipes for gas, water and chemicals. Easi-Duct access troughs and ducts can be buried underground, located above, or flush with surface levels to provide protection against accidental or malicious damage and to offer easy access for maintenance and repair. Three types of flush fitting lids are supplied in either reinforced precast concrete, GRP composite, or steel tray. All are designed and tested for loading group class to BS EN 124.

Typical Easi-Duct applications include; rail and highway infrastructure; power stations; gas, oil and chemical installations; industrial, commercial and domestic developments; docks and harbours; water and sewage treatment plants.

BenefitsCompared with the alternatives of direct burying of cables and pipes or overhead suspension, Easi-Duct has a number of advantages:-

Applicable to power and telecom cables in addition to pipes for liquids and gases

Chemically resistant concrete

Services buried at depth are unexposed to weather changes (i.e. freezing or overheating)

High strength load bearing units

Easy access for cable repair, jointing or new cable additions

Whole life costing of precast concrete is lower than other forms of ducting construction

Non conductive to electricity

FP McCann can produce specialist units moulded to requirement

Design FeaturesThe troughs, ducts and lids are designed and tested for load classes A15, B125, C250 and D400. For loadings E600 and F900, Easi- Duct systems are designed, tested and manufactured specific to order.

Page 60: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P59

QualityFP McCann Easi-Duct systems are designed, manufactured and strength tested to comply with loading criteria as set out in accordance with BS EN 1433 (Troughs) and BS EN 124 (Lids). All operations are conducted in accordance with FP McCann’s quality management system, BSI accredited to BS EN ISO 9001.

Trough Table 1: 1000 to 1250 Width

Power Infrastructure Cable Ducting Systems

Infrastructure & Power

Reference(width x depth x length)

Trough Coding Description

s/w*nominal

kg

Supplied withLid reference

Volumem3

Reinfno allowance

for scrapkg per unit

Reinfkg/m3

Reinf%

Trough Dimensions (mm)

A B C D E F

1250 x 1250 x 1000

MT 1250 1250 ABCD

SL

1250W x 1250D x 1000L SL

1915 ML 1250 250 TH CD 0.7661 76.8 100.2 4.01 1250 1300 1500 1380 1505 1700

MT 1250 1250 ABCD

LL

1250W x 1250D x 1000L

Trough LL

1915 ML 1250 150 RC AB or ML 1250 ST CD 0.7661 76.8 100.2 4.01 1250 1250 1500 1375 1505 1700

1250 x 1000 x 1000

MT 1250 1000 ABCD

SL

1250W x 1000D x 1000L SL

1708 ML 1250 250 TH CD 0.683 64.3 94.1 3.77 1250 1050 1250 1355 1505 1700

MT 1250 1000 ABCD

LL

1250W x 1000D x 1000L

Trough LL

1708 ML 1250 150 RC AB or ML 1250 ST CD 0.683 64.3 94.1 3.77 1250 1000 1250 1350 1505 1700

1250 x 750 x 1000

MT 1250 750 ABCD SL

1250W x 750D x 1000L

Trough SL

1484 ML 1250 250 TH CD 0.5936 59.2 99.7 3.99 1250 800 1000 1330 1505 1700

MT 1250 750 ABCD LL

1250W x 750D x 1000L

Trough LL

1484 ML 1250 150 RC AB or ML 1250 ST CD 0.5936 59.2 99.7 3.99 1250 750 1000 1325 1505 1700

1000 x 1000 x 1000

MT 1000 1000 ABCD

SL

1000W x 1000D x 1000L

Trough SL

1539ML 1000 50 ODT A

or ML 1000 50 CDS Aor ML 1000 50 250 TH CD

0.6155 64.5 104.8 4.19 1000 1050 1250 1105 1230 1425

MT 1000 1000 ABCD

LL

1000W x 1000D x 1000L

Trough LL

1539 ML 1000 100 RC AB or ML100 ST CD 0.6155 64.5 104.8 4.19 1000 1000 1250 1100 1230 1425

1000 x 750 x 1000

MT 1000 750 ABCD SL

1000W x 750D x 1000L SL

1331ML 1000 50 ODT A

or ML 1000 50 CDS Aor ML 1000 50 250 TH CD

0.5324 52.6 98.8 3.95 1000 800 1000 1080 1230 1425

MT 1000 750 ABCD LL

1000W x 750D x 1000L

Trough LL

1331 ML 1000 100 RC AB or ML100 ST CD 0.5324 52.6 98.8 3.95 1000 750 1000 1075 1230 1425

1000 x 500 x 1000

MT 1000 500 ABCD SL

1000W x 500D x 1000L

Trough SL

1108ML 1000 50 ODT A

or ML 1000 50 CDS Aor ML 1000 50 250 TH CD

0.4430 46.7 105.4 4.22 1000 550 750 1055 1230 1425

MT 1000 500 ABCD LL

1000W x 500D x 1000L

Trough LL

1108 ML 1000 100 RC AB or ML100 ST CD 0.4430 46.7 105.4 4.22 1000 500 750 1050 1230 1425

* maximum self weight = nominal self + 5%, which should be used to size lifting equipment

Page 61: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P60Power Infrastructure Cable Ducting Systems

Trough Table 2: 350 to 750 Width

Infrastructure & Power

Reference(width x depth x length)

Coding Description

LoadinggroupClass

to BS EN 124

s/w *nominal

kg

Supplied withLid reference

Volumem3

Reinforcementno allowance for scrap Trough Dimensions (mm)

kg per unit kg/m3 % A B C D E F

750 x 750 x 1000

MT 750 750 ABCD

SL

750W x 750D x 1000L

Trough SL

A,B,C &D 1115ML 750 50 ODT A

or ML 750 50 CDS Aor ML 750 250 TH CD

0.4461 43.3 97.1 3.88 750 800 1000 830 955 1125

MT 750 750 ABCD

LL

750W x 750D x

1000L LLA,B,C &D 1115 ML 750 100 RC AB

or ML 750 100 ST CD 0.4461 43.3 97.1 3.88 750 750 1000 825 955 1125

750 x 500 x 1000

MT 750 500 ABCD

SL

750W x 500D x 1000L

Trough SL

A,B,C &D 923ML 750 50 ODT A

or ML 750 50 CDS Aor ML 750 250 TH CD

0.3692 37.9 102.7 4.11 750 550 750 805 955 1125

MT 750 500 ABCD

LL

750W x 500D x 1000L

Trough LL

A,B,C &D 923 ML 750 100 RC AB or ML 750 100 ST CD 0.3692 37.9 102.7 4.11 750 500 750 800 955 1125

600 x 600 x 1000

MT 600 600 ABCD

SL

600W x 600D x 1000L

Trough SL

A,B,C &D 810ML 600 50 ODT A

or ML 600 50 CDS Aor ML 600 50 CDS B

0.3240 15.1 46.7 1.87 570 600 800 630 750 900

MT 600 600 ABCD

LL

600W x 600D x 1000L

Trough LL

A,B,C &D 810 ML 600 100 RC AB or ML 600 ST CD 0.3240 14.8 45.8 1.83 570 550 800 625 750 900

600 x 300 x 1000

MT 600 300 ABCD

SL

600W x 300D x 1000L

Trough SL

A,B,C &D 596ML 600 50 ODT A

or ML 600 50 CDS Aor ML 600 50 CDS B

0.2385 12.6 52.9 2.11 570 300 500 600 750 900

MT 600 300 ABCD

LL

600W x 300D x 1000L

Trough LL

A,B,C &D 596 ML 600 100 RC AB or ML 600 ST CD 0.2385 12.1 50.6 2.02 570 250 500 595 750 900

350 x 300 x 1000

MT 350 300 ABCD

SL

350W x 300D x 1000L

Trough SL

A,B,C &D 450ML 350 50 ODT A

or ML 350 50 CDS Aor ML 350 50 CDS B

0.1801 7.6 42.1 1.68 350 350 525 385 510 635

MT 350 300 ABCD

LL

350W x 300D x 1000L

Trough LL

A,B,C &D 450 ML 350 100 RC AB or ML 350 100 ST CD 0.1801 7.3 40.4 1.61 350 300 525 380 510 635

* maximum self weight = nominal self + 5%, which should be used to size lifting equipment

Page 62: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P61

Corner and ‘Tee’ UnitsCorner, ‘Tee’ troughs and lids are made to order. The units incorporate galvanised steel angles to support lids where necessary and curved inner corners to allow ease of cable laying. For dimensions and technical specification refer to the FP McCann website.

Power Infrastructure Cable Ducting Systems

Infrastructure & Power

Page 63: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P62Power Infrastructure Cable Ducting Systems

Lid Table 1: All sizes

Infrastructure & Power

Reference(width x depth x

length) (width = span

width)

Reference(width x depth

x length) (width = span

width)

Lid Coding Description

LoadinggroupClass

to BS EN 124

s/w*nominal

kg

Averagewidth

(inc bearing width)

Volume

reinfperlidkg

Lid Dimensions (mm)

A B C

1250 x 150 x 500 1250 5T Concrete Lid

ML 1250 150 RC AB

Reinforced concrete recessed Lid to fit 1250 wide trough with 150 deep rebate 5T SWL A and B 1484 0.113 22.1 1499 1469 150

1250 x 150 x 5001250 11.5T

Recessed Steel Tray Lid

ML 1250 150 ST CD

Composite (steel tray + concrete infill) Lid to fit 1250 wide trough with 150 deep rebate 11.5T SWL C and D 279.0 1499** 1479** 150**

1250 x 225 x 500 1250 11.5T RC Top Hat Lid

ML 1250 225 TH CD

Reinforced concrete top hat Lid to fit 1250 wide trough 11.5T SWL C and D 0.123 45.19 1700 1480 225

1000 x 50 x 1000 1000 GRP Open Pedestrian Lid

ML 1000 50 ODT A

Open GRP “Dura Tread” Lid to fit 1000 wide trough with 50 deep rebate 1.5T SWL A 28.6 1224 1214 50

1000 x 50 x 10001000 GRP

Closed Pedestrian Lid

ML 1000 50 CDS A

Closed GRP “Dura Slab” Lid to fit 1000 wide trough with 50 deep rebate 1.5T SWL A 35.7 1224 1214 50

1000 x 100 x 500 1000 5T Concrete Lid

ML 1000 100 RC AB

Reinforced concrete recessed Lid to fit 1000 wide trough with 100 deep rebate 5T SWL A and B 151.1 1214 0.061 12.73 1224 1204 100

1000 x 100 x 5001000 11.5T

Recessed Steel Tray Lid

ML 1000 100 ST CD

Composite (steel tray + concrete infill) Lid to fit 1000 wide trough with 100 deep rebate 11.5T SWL C and D 151.1 1224** 1204** 100**

1000 x 225 x 500 1000 11.5T RC Top Hat Lid

ML 1000 225 TH CD

Reinforced concrete top hat Lid to fit 1000 wide trough 11.5T SWL C and D 391.0 0.156 26.75 1425 1205 225

750 x 50 x 1000 750 GRP Open Pedestrian Lid

ML 750 50 ODT A

Open GRP “Dura Tread” Lid to fit 750 wide trough with 50 deep rebate 1.5T SWL A 22.2 949 939 50

750 x 50 x 1000 750 GRP Closed Pedestrian Lid

ML 750 50 CDS A

Closed GRP “Dura Slab” Lid to fit 750 wide trough with 50 deep rebate 1.5T SWL A 27.6 949 939 50

750 x 100 x 500 750 5T Concrete Lid

ML 750 100 RC AB

Reinforced concrete recessed Lid to fit 750 wide trough with 100 deep rebate 5T SWL A and B 116.9 939 0.047 8.64 949 929 100

750 x 100 x 500750 11.5T

Recessed Steel Tray Lid

ML 750 100 ST CD

Composite (steel tray + concrete infill) Lid to fit 750 wide trough with 100 deep rebate 11.5T SWL C and D 116.9 949** 929** 100**

750 x 225 x 500 750 11.5T RC Top Hat Lid

ML 750 225 TH CD

Reinforced concrete top hat Lid to fit 750 wide trough 11.5T SWL C and D 0.123 17.27 1125 905 250

600 x 50 x 1000 600 GRP Open Pedestrian Lid

ML 600 50 ODT A

Open GRP “Dura Tread” Lid to fit 600 wide trough with 50 deep rebate 1.5T SWL A 17.4 744 724 50

600 x 50 x 1000 600 GRP Closed Pedestrian Lid

ML 600 50 CDS A

Closed GRP “Dura Slab” Lid to fit 600 wide trough with 50 deep rebate 1.5T SWL A 21.6 744 724 50

600 x 50 x 475 600 GRP Closed 5T Lid

ML 600 50 CDS B

Closed GRP “Dura Slab” Lid to fit 600 wide trough with 50 deep rebate 5T SWL B 12.8 744 724 50

600 x 100 x 500 600 5T Concrete Lid

ML600 100 RC AB

Reinforced concrete recessed Lid to fit 600 wide trough with 100 deep rebate 5T SWL A and B 91.4 734 0.037 6.59 744** 724** 100**

600 x 100 x 500600 11.5T

Recessed Steel Tray Lid

ML 600 100 ST CD

Composite (steel tray + concrete infill) Lid to fit 600 wide trough with 100 deep rebate 11.5T SWL C and D 91.4 744 724 100

350 x 50 x 1000 350 GRP Open Pedestrian Lid

ML 350 50 ODT A

Open GRP “Dura Tread” Lid to fit 350 wide trough with 50 deep rebate 1.5T SWL A 11.7 504 494 50

350 x 50 x 1000 350 GRP Closed Pedestrian Lid

ML 350 50 CDS A

Closed GRP “Dura Slab” Lid to fit 350 wide trough with 50 deep rebate 1.5T SWL A 14.6 504 494 50

350 x 50 x 475 350 GRP Closed 5T Lid

ML 350 50 CDS B

Closed GRP “Dura Slab” Lid to fit 350 wide trough with 50 deep rebate 5T SWL B 8.6 504 494 50

350 x 100 x 500 350 5T Concrete Lid

ML 350 100 RC AB

Reinforced concrete recessed Lid to fit 350 wide trough with 100 deep rebate 5T SWL A and B 61.5 494 0.025 4.21 504** 484** 100**

350 x 100 x 500350 11.5T

Recessed Steel Tray Lid

ML 350 100 ST CD

Composite (steel tray + concrete infill) Lid to fit 350 wide trough with 100 deep rebate 11.5T SWL C and D 61.5 504 484 100

* maximum self weight = nominal self + 5%, which should be used to size lifting equipment** Please note, these figures are currently under review, please refer to the website for updated information.

Page 64: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P63

A unique cable and junction protection box o"ering easy access for maintenance. This reinforced concrete unit can be installed in minutes with the one piece construction design preventing ground water leakage and associated assembly requirements. Comms Boxes are mainly used in infrastructure works to include airports, railway projects, roads and housing developments.

Comms J4

FeaturesReinforced walls Easily manoeuvred with lifting eyesPreformed cable entry points Ironmongery #ttedReduced carbon footprint

Dimensions Length Width HeightInternal Dimensions 900mm 430mm 800mmWeight *(Nominal) 615kgs

Comms C2

Dimensions Length Width Height

Internal Dimensions 1200mm 600mm 895mm

Weight *(Nominal) 1400kgs

Infrastructure & Power

BT Approved Comms Boxes

*Maximum self weight = Nominal + 5%, which should be used to size lifting equipment.Note, BT N.I Approved

Page 65: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P64

Comms DP

Comms MCX

Dimensions Length Width Height

Internal Dimensions 910mm 890mm 1000mm

Weight *(Nominal) 1565kgs

Dimensions Length Width Height Weight *(Nominal)

Chamber 1300mm 850mm 900mm 2160kgs

Riser 1300mm 850mm 300mm 470kgs

Concrete Cover Slab 1570mm 1120mm 150mm 660kgs

Infrastructure & Power

BT Approved Comms Boxes

*Maximum self weight = Nominal + 5%, which should be used to size lifting equipment.Note, BT N.I Approved

Page 66: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P65

Easi-Bloc is a precast concrete block, offering solutions where limited space is available for containment. Blocs are simplistic in design allowing for effortless handling and speed of installation.

Easi-Bloc comes in two sizes making them ideal for a variety of applications.

Easi-Bloc

Length (mm) Width (mm) Height (mm) Weight (t)1400 700 700 1.7700 700 700 0.85

ApplicationsIdeal for a variety of uses to include:

Infrastructure & Power

Features Cost effective Easy to handle and install Durable

Easi-Bloc contains a central cast in lifting loop for ease of handling and installation

Products are manufactured to comply with the requirements of BS EN 1992-1-1:2004.

Page 67: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P66

As a leading producer of high quality, durable rail products, FP McCann is committed to ensuring quality and best practice. FP McCann holds a large quantity of stock and manufactures a full range of troughing special products, such as tees, transitions, curves and our own version of a transformer base/locations base, which are approved to Network Rail specifications.

FP McCann is a Link Up and Supply Line approved supplier (Link Up Approval Certificate Number 10844-25579/75761; Supplier Number 25579 - Network Approval to NR/PS/TEL/00013 and FTN/HQ/SP/P/0001, Certificate Number: PA 05/01429.

All railway products are manufactured in accordance with FP McCann’s quality management system, BSI accredited to BS EN ISO 9001.

Rail Products

A Railway brochure with details on our full product range is available to view or download from our website at www.fpmccann.co.uk/ebrochures or alternatively contact a member of our sales team

Page 68: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P67Rail ProductsCable Protection Troughs

FP McCann manufacture and stock over 30 different types of “C” cable protection troughs and lids. Electricity service cables and trunking are completely protected from accidental damage or acts of vandalism whilst allowing for ease of access to maintenance teams.

Platform Copings

FP McCann is an approved manufacturer and supplier of platform copings to Network Rail and London Underground specifications. Copings are manufactured to BS 8110 and conform to slip resistance requirements as laid out in BS 7976-2 Pendulum test accredited. Network Rail copings are available in two industry approved sizes in a standard grey colour. Requests for non-standard product sizes and colours are accepted. London Underground nosing slabs are available from stock.

As well as the standard straight troughs and curves, we supply a range of specials including Tees, transitions and transformer/location bases, all to Network Rail Approval.

FP McCann “C” Series precast concrete troughs installed alongside existing troughs to carry additional power and communication cables.

Page 69: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P68

From our recently extended factory at Cadeby, we combine over 30 years experience to provide an extensive range of attractive, durable and practical fencing solutions.

The range includes: slotted posts, with gravel boards to suit; morticed posts; recessed posts; chainlink posts; universal posts and screed rails.

Our gravel boards are available in a selection of attractive designs including brick and rock-faced patterns.

Concrete fence posts are becoming a popular alternative to wooden posts, offering greater strength and durability, and of course, will last much longer.

Easy to handle Fenn-Lite fencing posts and gravel boards are up to 45% lighter and offer the same strength and durability as standard weight products.

FP McCann now offers Easi-Order, an online ecommerce tool that has been designed to simplify the ordering process for our fencing stockists.

Available Nationwide

Our sales team is on hand to discuss your requirements and can recommend the right product for you.

We can deliver our fencing products anywhere in the UK.

All fencing products are manufactured in accordance with FP McCann’s quality management system, BSI accredited to BS EN ISO 9001.

A Fencing brochure with details on our full product range is available to view or download from our website at www.fpmccann.co.uk/ebrochures or alternatively contact a member of our sales team

Fencing Products

Page 70: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P69Bespoke Specialist Products

To find out more about the specials FP McCann can manufacture, contact the sales or technical team at any of our locations, or email your requirements to [email protected].

FP McCann is able to manufacture special and bespoke products having dedicated wetcast production facilities at each of it’s locations.

Our dedicated team of concrete engineers and designers are able to provide certified structural detail to units required for specialist applications. Casting is undertaken by skilled detailers and production operatives in quality-controlled factory conditions.

Bespoke products include:

Valve ChambersTerrace Slabs

Storage Tanks Retaining Walls Hydrodynamic Separators

Protective Walls Specialist Kerbs

Page 71: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

www.fpmccann.co.uk [email protected]

P70Notes

Page 72: Product Selector · PDF file · 2014-04-14We hold BSI kitemark accreditation and applicable products are manufactured to the relevant parts of BS EN 1916 and BS EN1917. ... along

Knockloughrim Quarry3 Drumard Road

MagherafeltBT45 8QA

Tel: 028 7964 2558Fax: 028 7964 4224

[email protected]

Head Office

AlnwickLittle Houghton

NorthumberlandEnglandNE66 3JX

TelfordDoseley Telford

ShropshireTF4 3BX

Sales & General EnquiriesDRAINAGE PRODUCTS SCOTLAND, NI & ROI

Knockloughrim Plant16-18 Quarry Road

KnockloughrimMagherafelt

BT45 8NR

Tel: 028 7954 9043Fax: 028 7954 9993

DRAINAGE PRODUCTS UKEllistown

Whitehill RoadLeicestershire

EnglandLE67 1ET

Tel: 01530 240000Fax: 01530 240013

Production Plants

SHAFTS & TUNNELS, FENCING & RAIL PRODUCTS

CadebyBrasscote Lane

Cadeby, NuneatonWarks

CV13 0BB

Tel: 01455 290780Fax: 01455 292189

BOX CULVERTSAlfreton

Unit 6 Keypoint O!ce VillageKeys Road

Nix’s Hill Industrial EstateAlfreton, Derbyshire

DE55 7FQ

Tel: 01773 520273Fax: 01773 546514