Degas and Regas PFA Membrane Contactor Temperature Control (Optional) PFA Heat Exchangers 5853 EUV Symposium PRODUCTION OF HIGH-PURITY FUNCTIONAL WATER AT POINT-OF-USE FOR ADVANCED MASK CLEANING PROCESSES Annie Xia, Entegris, Inc. Concept of Point-of-Use Ultra-pure Functional Water Polishing and Gasification System Summary • A point-of-use functional water delivery system using membrane contacting technology enables: – Purification and filtration at point-of-use – Precise control at point-of-use – Less chance of contamination at point-of-use • Automatic control of dissolved gas concentration brings added benefit of ensuring a stable and seamless cleaning process Typical Ionic Purification and Particle Removal Install 10 nm particle filter 8.7 Particles/L (27 data point average) Background Time (hours) 0 2 4 6 8 10 12 14 16 18 20 Cumulative Particles/Liter 0.05 μm with UDI 50 1000000 100000 10000 1000 100 10 1 0.1 Particle Shedding in DI Water @ 1 L/min • Typical outlet DI water contains PPQ levels of ionic species: – Less than 0.5 ppt/each element: Li, Na, Mg, Al, K, Ca, Ti, Cr, Fe, Mn, Ni, Cu, … • Typical outlet DI water contains single digit particles per liter Outlet DI water particles <10 counts/Liter (>0.05 μm) Liquid Gasification Using Membrane Contactor Gas permeate Feed gas Hollow fiber membrane Hollow Fiber Membrane Gas outlet Gas inlet Liquid inlet Liquid outlet Tube bundle All PFA Membrane Contactor All PFA ultra-clean construction • Low extractable and particles • Excellent chemical compatibility PFA hollow fiber membrane • Only gas permeable, hydrophobic • 2 m 2 membrane surface Low pressure drop • <7 kPa @ 8 L/min water flow Definition of Functional Water Physical/Chemical Processing • Electrolysis • Gasification • Chemical Addition • Light Irradiation • Ultrasonic Excitation Functional Water Altered physical/chemical properties: • Dielectric constant • Viscous force • Electrical conductivity • Surface tension • Oxidation-reduction potential Pure Water Enhanced Cleaning Efficiency Abstract Without the use of traditional pellicles, EUV masks demand high purity and effective but mild cleaning techniques for protection from defects. Recently, trends towards dilute chemistries and progress in megasonic cleaning have brought renewed interest in gasified DI water. In this paper, we describe the design and development of a point-of-use functional water treatment system, specifically for advanced mask cleaning applications. The system is comprised of two modules— the purification module and the gasification module. The purification module provides treatment features including TOC reduction, sub-micron particle retention, as well as thermal and pressure control. The gasification module is capable of delivering bubble-free DI water with various gases (O 3 , N 2 , H 2 , CO 2 , NH 3 , etc.) over a wide concentration range. The gasification module is also equipped with automatic dissolved gas concentration control features to allow precise control and minimal process variations. Limitations of Sulfur-based Wet Cleaning Process • Hot DIW rinse may cause wear on masks • Ionic residues – Haze • Too aggressive causing film loss • Limited number of cleans Rinse Clean DIW Rinse Particle Removal APM + Megasonic (NH 4 OH + H 2 O 2 + H 2 O) Current Chemistry Drawbacks • Particulates in SPM • (SO 4 2- ) residuals – Haze • Contaminants unremovable by SPM Organics Removal SPM (H 2 SO 4 + H 2 O 2 + H 2 O) Current cleaning processes do not provide mask surfaces that are free from contamination. Adders Direct gas injection. No gas or liquid mixing. Sulfur-free Cleaning Using Functional Water • Made at point-of-use • Cleaner than SPM (sulfuric peroxide mixture) • No waste except H 2 O and gas • Relatively low cost • Good cleaning efficiency • Compatible with existing tools • Environmentally friendly • Can be room temperature New Chemistry Organics Removal O 3 /DI Water ( 5–50 ppm) Particle Removal H 2 /DI Water + Megasonic (<3 ppm) Rinse Clean DI Water Rinse CO 2 /DI Water (Optional) Advantages of Functional Water Recirc Pump To mask clean tool Clean DI Water with Controlled • Temperature • Dissolved gas concentration Purification Gasification and Control Gasification System Control Performance Resistivity = 1/ Conductivity Conductivity Sensor: Horiba HE-480 Water Temp = 23°C Time (min) 0 1 2 3 4 5 Resistivity (MOhm-cm) DI Water Flow (L/min) 0.100 0.090 0.080 0.070 0.060 0.050 0.040 0.030 0.020 0.010 0.000 20 18 16 14 12 10 8 6 4 2 0 Dissolved CO 2 Concentration (Water Resistivity) Stability within ±5% of Setpoint Target Resistivity = 0.05 MΩ-cm Dissolved CO 2 concentration Water flow 1.5 1.5 L/min (every 30 seconds) 10.5 10.5 18 3 3 6 6 Water Ozonation and Hydrogenation Efficiency 0 5 10 15 20 25 30 70 60 50 40 30 20 10 0 Dissolved O 3 Concentration vs. Water Flow (Single Membrane Contactor) DI Water Flow (L/min) Dissolved O 3 in Water (ppm) To adjust dissolved O 3 concentrations: • Inlet O 3 concentration , Dissolved O 3 concentration ; vice versa • Inlet O 2 flow , Dissolved O 3 concentration ; vice versa To adjust dissolved H 2 concentration at a given flow: • H 2 pressure , Dissolved H 2 concentration ; vice versa 0 0.02 0.04 0.06 0.08 0.1 0.12 2.5 2.0 1.5 1.0 0.5 0 Dissolved H 2 Concentration vs. H 2 Pressure (Single Membrane Contactor) H 2 Pressure (MPa) Dissolved H 2 in Water (ppm) Automated DI Water Gasification Process How does the control system work? • Dissolved gas sensor sends feedback to closed loop controller • Closed loop controller keeps adjusting gas flow until dissolved gas sensor measurement matches the setpoint Dissolved gas sensor DI water inlet Gasified DI water outlet Gas exhaust MFC At a constant water temperature: Gas P or flow , Gas solubility Gas P or flow , Gas solubility To single/batch type cleaning tools Closed loop controller Degas and regas in one step Types of Dissolved Gas Sensors O 3 -DIW Dissolved O 3 sensor ORP sensor H 2 -DIW Dissolved H 2 sensor ORP sensor N 2 -DIW Dissolved N 2 sensor CO 2 -DIW Dissolved CO 2 sensor pH meter Resistivity sensor ORP – Oxidation Reduction Potential 0 1 2 3 4 5 10.00 9.00 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 3.0 2.5 2.0 1.5 1.0 0.5 0 Without Auto Concentration Control Time (min) Conductivity (μS/cm) DI Water Flow (L/min) Dissolved CO 2 concentrate Water flow Conductivity DI water flow 0 1 2 3 4 5 10.00 9.00 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 3.0 2.5 2.0 1.5 1.0 0.5 0 With Auto Concentration Control Time (min) Conductivity (μS/cm) DI Water Flow (L/min) Dissolved CO 2 concentrate Water flow Conductivity DI water flow Why do we need to control gas concentration? 0 10 20 30 40 50 60 O 3 Concentration vs. Cleaning Efficiency Remaining Counts (-) DI0 3 Concentration (ppm) 100000 10000 1000 100 10 1 SPM DIO3 Source: Investigation of Sulfur Free Clean Processes for Next Generation Lithography. C. Chovino, et al, AMTC GmbH. O 3 concentration affects cleaning efficiency Maintaining stable O 3 concentration Consistent cleaning efficiency Auto concentration control minimizes process variability Organic and Ion Removal UV + Ion Exchangers Facility DI Water Particle Removal Filtration Test condition: DI water flow – 6 L/min Water temperature – 25°C Test condition: Ozone generator — O2 : 5 SLPM; 250 g/Nm 3 Water temperature — 25°C Water Gas Gas molecule Boundary layer Gas-liquid interface Hydrophobic membrane Flow Gas flow Gas diffusion Membrane Interface Resistivity DI water flow

Upload: dinhphuc

Post on 07-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Degas and RegasPFA Membrane Contactor

Temperature Control(Optional)

PFA Heat Exchangers

5853 EUV Symposium

PRODUCTION OF HIGH-PURITY FUNCTIONAL WATER ATPOINT-OF-USE�FOR ADVANCED MASK CLEANING PROCESSES

Annie Xia, Entegris, Inc.

Concept of Point-of-Use Ultra-pure Functional Water Polishing and Gasification System

Summary• A point-of-use functional water delivery system using membrane contacting technology enables: – Purification and filtration at point-of-use – Precise control at point-of-use – Less chance of contamination at point-of-use

• Automatic control of dissolved gas concentration brings added benefit of ensuring a stable and seamless cleaning process

Typical Ionic Purification and Particle Removal

Install 10 nm particle filter

8.7 Particles/L(27 data point average)

Background

Time (hours)0 2 4 6 8 10 12 14 16 18 20

Cum

ulat

ive

Part

icle

s/Li

ter

≥0.0

5 µm

with

UDI

50

1000000

100000

10000

1000

100

10

1

0.1

Particle Shedding in DI Water @ 1 L/min• Typical outlet DI water contains PPQ levels

of ionic species: – Less than 0.5 ppt/each element: Li, Na, Mg, Al, K, Ca, Ti, Cr,

Fe, Mn, Ni, Cu, …

• Typical outlet DI water contains single digit particles per liter

Outlet DI water particles

<10 counts/Liter (>0.05 µm)

Liquid Gasification Using Membrane ContactorGas permeate

Feed gasHollowfiber

membrane

Hollow Fiber Membrane

Gas outlet

Gas inlet

Liquid inlet

Liquid outlet

Tube bundle

All PFA Membrane Contactor

All PFA ultra-clean construction• Low extractable and particles• Excellent chemical compatibility

PFA hollow fiber membrane• Only gas permeable, hydrophobic• 2 m2 membrane surface

Low pressure drop• <7 kPa @ 8 L/min water flow

Definition of Functional WaterPhysical/ChemicalProcessing• Electrolysis• Gasification• Chemical Addition• Light Irradiation• Ultrasonic Excitation

Functional WaterAltered physical/chemical properties:

• Dielectric constant• Viscous force• Electrical conductivity• Surface tension• Oxidation-reduction potential

Pure Water

Enhanced Cleaning Efficiency

AbstractWithout the use of traditional pellicles, EUV masks demand high purity and effective but mild cleaning techniques for protection from defects. Recently, trends towards dilute chemistries and progress in megasonic cleaning have brought renewed interest in gasified DI water.

In this paper, we describe the design and development of a point-of-use functional water treatment system, specifically for advanced mask cleaning applications. The system is comprised of two modules— the purification module and the gasification module. The purification module provides treatment features including TOC reduction, sub-micron particle retention, as well as thermal and pressure control. The gasification module is capable of delivering bubble-free DI water with various gases (O3, N2, H2, CO2, NH3, etc.) over a wide concentration range. The gasification module is also equipped with automatic dissolved gas concentration control features to allow precise control and minimal process variations.

Limitations of Sulfur-based Wet Cleaning Process

• Hot DIW rinse may cause wear on masks

• Ionic residues – Haze

• Too aggressive causing film loss

• Limited number of cleans

Rinse Clean

DIW Rinse

Particle Removal

APM + Megasonic(NH4OH + H2O2 + H2O)

CurrentChemistry

Drawbacks• Particulates in SPM

• (SO42-) residuals – Haze

• Contaminants unremovable by SPM

Organics Removal

SPM(H2SO4 + H2O2 + H2O)

Current cleaning processes do not provide mask surfaces that are free from contamination. Adders

Direct gas injection. No gas or liquid mixing.

Sulfur-free Cleaning Using Functional Water

• Made at point-of-use• Cleaner than SPM (sulfuric

peroxide mixture)• No waste except H2O and gas• Relatively low cost

• Good cleaning efficiency• Compatible with existing tools• Environmentally friendly• Can be room temperature

NewChemistry

Organics Removal

O3/DI Water( 5–50 ppm)

Particle Removal

H2/DI Water + Megasonic(<3 ppm)

Rinse Clean

DI Water RinseCO2/DI Water (Optional)

Advantages of Functional Water

RecircPump

To mask clean tool

Clean DI Water with Controlled• Temperature• Dissolved gas concentration

Purification

Gasification and Control

Gasification System Control Performance

Resistivity = 1/ ConductivityConductivity Sensor: Horiba HE-480 Water Temp = 23°C

Time (min)0 1 2 3 4 5

Res

istiv

ity (

MO

hm-c

m)

DI W

ater

Flo

w (

L/m

in)

0.100

0.090

0.080

0.070

0.060

0.050

0.040

0.030

0.020

0.010

0.000

20

18

16

14

12

10

8

6

4

2

0

Dissolved CO2 Concentration (Water Resistivity)Stability within ±5% of Setpoint

Target Resistivity = 0.05 MΩ-cm

Dissolved CO2

concentration

Water flow

1.5 1.5 L/min (every 30 seconds)10.5 10.5183 36 6

Water Ozonation and Hydrogenation Efficiency

0 5 10 15 20 25 30

70

60

50

40

30

20

10

0

Dissolved O3 Concentration vs. Water Flow(Single Membrane Contactor)

DI Water Flow (L/min)

Diss

olve

d O

3 in

Wat

er (

ppm

)

To adjust dissolved O3 concentrations:• Inlet O3 concentration , Dissolved O3 concentration ; vice versa• Inlet O2 flow , Dissolved O3 concentration ; vice versa

To adjust dissolved H2 concentration at a given flow:• H2 pressure , Dissolved H2 concentration ; vice versa

0 0.02 0.04 0.06 0.08 0.1 0.12

2.5

2.0

1.5

1.0

0.5

0

Dissolved H2 Concentration vs. H2 Pressure(Single Membrane Contactor)

H2 Pressure (MPa)

Diss

olve

d H

2 in

Wat

er (

ppm

)

Automated DI Water Gasification ProcessHow does the control system work?• Dissolved gas sensor sends feedback to closed loop controller• Closed loop controller keeps adjusting gas flow until dissolved

gas sensor measurement matches the setpoint

Dissolved gassensor

DI water inlet

Gasified DIwater outlet

Gas exhaust

MFC

At a constant water temperature:Gas P or flow , Gas solubilityGas P or flow , Gas solubility

To single/batch typecleaning tools

Closed loopcontroller

Degas and regas in one step

Types of Dissolved Gas Sensors

O3-DIW Dissolved O3 sensor

ORP sensor

H2-DIW Dissolved H2 sensor

ORP sensor

N2-DIW Dissolved N2 sensor

CO2-DIW Dissolved CO2 sensor

pH meter

Resistivity sensorORP – Oxidation Reduction Potential

0 1 2 3 4 5

10.009.008.007.006.005.004.003.002.001.000.00

3.0

2.5

2.0

1.5

1.0

0.5

0

Without Auto Concentration Control

Time (min)

Cond

uctiv

ity (

µS/c

m)

DI W

ater

Flo

w (

L/m

in)

Dissolved CO2 concentrate

Water flow

Conductivity DI water flow

0 1 2 3 4 5

10.009.008.007.006.005.004.003.002.001.000.00

3.0

2.5

2.0

1.5

1.0

0.5

0

With Auto Concentration Control

Time (min)

Cond

uctiv

ity (

µS/c

m)

DI W

ater

Flo

w (

L/m

in)

Dissolved CO2 concentrate

Water flow

Conductivity DI water flow

Why do we need to control gas concentration?

0 10 20 30 40 50 60

O3 Concentration vs. Cleaning Efficiency

Rem

aini

ng C

ount

s (-

)

DI03 Concentration (ppm)

100000

10000

1000

100

10

1

SPM

DIO3

Source: Investigation of Sulfur Free Clean Processes forNext Generation Lithography. C. Chovino, et al, AMTC GmbH.

O3 concentration affects cleaning efficiencyMaintaining stable O3 concentration

Consistent cleaning efficiency

Auto concentration controlminimizes process variability

Organic and Ion RemovalUV + Ion Exchangers

FacilityDI Water

Particle RemovalFiltration

Test condition:DI water flow – 6 L/minWater temperature – 25°C

Test condition:Ozone generator — O2: 5 SLPM; 250 g/Nm3

Water temperature — 25°C

Water

GasGas molecule

Boundary layer

Gas-liquid interface

Hydrophobicmembrane

Flow

Gas flowGas diffusion

Membrane Interface

Resistivity DI water flow