production of qcs operator station on …document title: production of qcs operator station on...

37
Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 1 of 37 Senior Manager, Engineering: Harish Gopalan Manager, Engineering: DCC: RJ Garside Originator: Anirudh Verma DATE: September 30, 2011 DATE: DATE: DATE: September 30, 2011 6510430198 Rev 00 Original Date Issued: Nov 29, 2010 Contents 1 About this document ...................................................................................................................... 3 1.1 Hardware ................................................................................................................................ 3 1.1.1 Dell Precision T5500 Work Station Views .................................................................... 3 1.1.2 T5500 Operator Station Back Panel Connectors and Card Slot details ......................... 4 2 Creating QCS Operator Station on Dell T5500 Platform .............................................................. 6 2.1 BIOS ....................................................................................................................................... 6 2.1.1 Configuring the BIOS settings ....................................................................................... 6 2.1.2 General Settings ............................................................................................................. 7 2.1.3 Drives Settings ............................................................................................................... 8 2.1.4 System Configuration Settings ....................................................................................... 8 2.1.5 Security Settings ............................................................................................................. 9 2.1.6 Power Management settings........................................................................................... 9 2.1.7 Post Behavior settings .................................................................................................. 10 2.2 RAID configuration.............................................................................................................. 10 2.2.1 Starting the RAID Configuration Program .................................................................. 10 2.3 Installation of Operating System using Experion PKS R400 system Initialization Media.. 11 2.3.1 Generating the Configuration Files for Target Machine .............................................. 11 2.3.2 Installing the Operating System on the Target Machine using Experion PKS R400 System Initialization Media ......................................................................................................... 18 2.4 Creating Boot media............................................................................................................. 22 2.5 Monitor Connection settings ................................................................................................ 22 2.6 Display Properties configuration .......................................................................................... 23 2.6.1 Display Properties Configuration for Single Monitor .................................................. 23 2.6.2 Display Properties Configuration for Dual Monitor .................................................... 26 2.7 Roxio Burning Software....................................................................................................... 30 2.7.1 Installation of Roxio Burning Software ....................................................................... 30 2.7.2 Roxio Burning Software Settings ................................................................................. 33 2.8 Installing the RAE ................................................................................................................ 35 3 Additional Information ................................................................................................................. 36 3.1 BIOS Update utility.............................................................................................................. 36 3.1.1 Installing the appropriate BIOS on R400.x platform ................................................... 36

Upload: lamkhuong

Post on 16-Mar-2018

219 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 1 of 37

Senior Manager, Engineering: Harish Gopalan

Manager, Engineering:

DCC: RJ Garside

Originator: Anirudh Verma

DATE: September 30, 2011 DATE: DATE: DATE: September 30, 2011 6510430198 Rev 00 Original Date Issued: Nov 29, 2010

Contents

1 About this document ...................................................................................................................... 3 1.1 Hardware ................................................................................................................................ 3

1.1.1 Dell Precision T5500 Work Station Views .................................................................... 3 1.1.2 T5500 Operator Station Back Panel Connectors and Card Slot details ......................... 4

2 Creating QCS Operator Station on Dell T5500 Platform .............................................................. 6 2.1 BIOS....................................................................................................................................... 6

2.1.1 Configuring the BIOS settings ....................................................................................... 6 2.1.2 General Settings ............................................................................................................. 7 2.1.3 Drives Settings ............................................................................................................... 8 2.1.4 System Configuration Settings....................................................................................... 8 2.1.5 Security Settings............................................................................................................. 9 2.1.6 Power Management settings........................................................................................... 9 2.1.7 Post Behavior settings .................................................................................................. 10

2.2 RAID configuration.............................................................................................................. 10 2.2.1 Starting the RAID Configuration Program .................................................................. 10

2.3 Installation of Operating System using Experion PKS R400 system Initialization Media.. 11 2.3.1 Generating the Configuration Files for Target Machine .............................................. 11 2.3.2 Installing the Operating System on the Target Machine using Experion PKS R400 System Initialization Media ......................................................................................................... 18

2.4 Creating Boot media............................................................................................................. 22 2.5 Monitor Connection settings ................................................................................................ 22 2.6 Display Properties configuration.......................................................................................... 23

2.6.1 Display Properties Configuration for Single Monitor.................................................. 23 2.6.2 Display Properties Configuration for Dual Monitor .................................................... 26

2.7 Roxio Burning Software....................................................................................................... 30 2.7.1 Installation of Roxio Burning Software ....................................................................... 30 2.7.2 Roxio Burning Software Settings................................................................................. 33

2.8 Installing the RAE................................................................................................................ 35 3 Additional Information................................................................................................................. 36

3.1 BIOS Update utility.............................................................................................................. 36 3.1.1 Installing the appropriate BIOS on R400.x platform ................................................... 36

Page 2: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 2 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Related documents

6510020334 - Real-Time Application Environment (RAE) R600 for Experion PKS R400.2 Release and

Installation Notes

51154481 - Experion PKS System Initialization Media Software Change Notice

46027201 - Ghost Backup for Da Vinci and MXProLine Systems user guide

EP-DSX256 - Fault Tolerant Ethernet Installation and Service Guide

EPDCSX36 – Software Installation Users Guide

EPDCX506 – Supplementary Installation Tasks Guide

Revision history

Rev DCN# Date Author Description of Changes

00 20832 29-Nov-2010 Halappa Begurappa

Barun Paul

Anirudh Verma

New document released.

01 20895 04-Jan-2011 Halappa Begurappa

Barun Paul

Anirudh Verma

Updated the procedure and screen shots in the Display Properties configuration chapter.

02 20970 30-Sep-2011 Halappa Begurappa

Barun Paul

Anirudh Verma

Updated the document with Experion PKS R400 system Initialization media R100.3 changes and BIOS update Utility.

Page 3: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 3 of 37

Honeywell Proprietary and Confidential DO NOT COPY

1 About this document This document provides instructions on production of QCS Operator Station on Windows 7 by using the Experion PKS system Initialization media (EXP Plus).

The instructions are applicable to Dell Precision T5500 (Non RAID) Workstations.

NOTE: For QCS Operator Station, Non RAID based Dell T5500 with single hard disks is used.

1.1 Hardware

For more information about Dell Precision T5500 (Non RAID) workstation, see section 1.1.1.

1.1.1 Dell Precision T5500 Work Station Views

Figure 1-1 T5500 Operator Station Front and Back View

Table 1-1 T5500 Operator Station connection description

Sl. No. Device Comments

1 Optical drives (2) This configuration contains one DVD+/-RW drive

2 Link integrity light -

3 Headphone connector -

4 Microphone connector -

5 Power button, power light -

6 Dell rotatable badge -

7 Diagnostic lights (4) -

Page 4: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 4 of 37

Honeywell Proprietary and Confidential DO NOT COPY

8 USB 2.0 connectors (2) -

9 Drive activity light -

10 Flex bay This configuration does not contain a floppy drive

11 Optical drive eject button -

12 Power supply diagnostic light -

13 Power supply diagnostic button

-

14 Power Connector

15 Back Panel connectors

16 Expansion card slots (6)

17 Cover-release latch and padlock ring

-

1.1.2 T5500 Operator Station Back Panel Connectors and Card Slot details

Below section provides back panel connector and card slot details of Dell T5500.

Figure 1-2 T5500 Operator Station Back Panel Connectors

Page 5: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 5 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Table 1-2 T5500 Operator Station back panel connection description

Sl. No. Connections Details Remarks

1 Parallel connector -

2 PS/2 mouse connector -

3 eSATA connector -

4 Line-out connector -

5 Network activity light -

6 Network adapter connector -

7 Link integrity light -

8 Line-in connector -

9 USB 2.0 connectors (6) -

10 PS/2 keyboard connector -

11 Serial connector -

Figure 1-3 T5500 Tower card slot details

Table 1-3 T5500 Operator Station card slot details

Slot No. Type Description

Slot-1 PCI Express x16 Slot Wired as x8

Slot for Installing Network card For FTE-Dual Port Intel Pro 1000 PT Ethernet

Slot-2 PCI Express x16 Slot Slot for Installing Video controller –

NVIDIA Quadro NVS295

Slot-3 PCI Express x16 Slot Wired as x8 -

Slot-4 PCI Express x16 Slot -

Slot-5 PCI -

Slot-6 PCI X -

Page 6: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 6 of 37

Honeywell Proprietary and Confidential DO NOT COPY

2 Creating QCS Operator Station on Dell T5500 Platform

To create an Operator Station on Dell T5500 platform, using Experion PKS R400 system Initialization media, you must perform the following tasks.

Table 2-1 T5500 Operator Station configuration steps

Task See Section Completed?

Configuring the BIOS settings 2.1.1 RAID configuration 2.2

Installation of Operating System using Experion PKS R400 system Initialization Media 2.3

Creating Boot media 2.4

Monitor Connection settings 2.5

Display Properties configuration 2.6

Roxio Burning Software 2.7

Installing the RAE 2.8

2.1 BIOS

2.1.1 Configuring the BIOS settings

ATTENTION: The Dell workstation comes with BIOS configuration settings based on the Honeywell CFI. However, it is recommended to verify, and reconfigure the same if needed.

CAUTION: The Dell workstation comes with Custom BIOS installed and it is recommended not to install any other version of the BIOS manually.

To configure the BIOS settings

1. Start the computer.

2. Press F2 as the computer boots to enter the setup utility.

The Dell Inc. Precision Workstation T5500 dialog box for BIOS settings appears.

Page 7: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 7 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-1 T5500 Operator Station Bios setting

2.1.2 General Settings

1. Expand Settings > General > Boot Sequence.

The Boot Sequence information is displayed in the right pane. The Boot sequence; must be in the following order.

Onboard or USB CD-ROM Drive.

SATA0-SAMSUNG HD161GJ

NOTE: Based on the manufacturer, the Hard Drive (HD) name listed under the Boot Sequence may vary.

Figure 2-2 T5500 Operator Station Boot Sequence

Page 8: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 8 of 37

Honeywell Proprietary and Confidential DO NOT COPY

NOTE: If necessary, you can change the order of the Boot Sequence by

using the button.

2.1.3 Drives Settings

1. Expand Settings >Drives > SATA Operation.

The SATA Operation information is displayed in the right pane.

2. From SATA Operation, select RAID Autodetect / AHCI.

A message box appears prompting you to confirm the selection made.

3. Click Yes to continue.

Figure 2-3 T5500 Operator Station RAID setting

2.1.4 System Configuration Settings

1. Expand Settings > System Configuration > Integrated NIC.

The Integrated NIC information is displayed in the right pane.

2. Under Integrated NIC, make sure it is Disable for systems with FTE connection.

NOTE: For the systems with FTE connections ensure Network Adapter 1000 PT Dual Port has been installed in the computer

Figure 2-4 T5500 Operator Station Integrated NIC setting

3. For systems, which does not intended for FTE use, make sure to Enable the same.

Page 9: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 9 of 37

Honeywell Proprietary and Confidential DO NOT COPY

2.1.5 Security Settings

After the System Configuration settings are complete continue with the Security settings.

4. Expand Settings > Security > Administrator Password.

The Administrator Password information is displayed in the right pane.

5. In the Administrator Password

Type the new password as hmxresult.

Type the new password again to confirm.

Click OK.

Figure 2-5 T5500 Operator Station Administrator password setting

6. Expand Settings > Security > Chassis Intrusion.

The Chassis Intrusion information is displayed in the right pane.

7. From Chassis Intrusion, select Enable.

Figure 2-6 T5500 Operator Station Chassis Intrusion setting

2.1.6 Power Management settings

1. Expand Settings > Power Management > AC Recovery.

The AC Recovery information is displayed in the right pane.

2. From AC Recovery, select Last Power State.

Page 10: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 10 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-7 T5500 Operator Station AC Recovery setting

2.1.7 Post Behavior settings

1. Expand Settings > Post Behavior > Fast Boot.

The Fast Boot information is displayed in the right pane.

2. From Fast Boot, clear the Enable Fast Boot option.

3. After completing all the BIOS settings click Apply and then click Exit. The system

will restart automatically.

2.2 RAID configuration

2.2.1 Starting the RAID Configuration Program

As Operator Station use Non RAID Dell T5500 computers, this section is NOT applicable to Operator Station.

NOTE: In Non RAID Dell T5500, after the system restart, the message prompting you to press <Ctrl+I> does not appear.

Page 11: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 11 of 37

Honeywell Proprietary and Confidential DO NOT COPY

2.3 Installation of Operating System using Experion PKS R400 system Initialization Media

CAUTION:

Users must use Experion PKS System Initialization R100.x (or Later) media along with HPS Operating System Reinstallation media to install Windows 7 operating system on the Honeywell qualified Dell Precision T5500 (Non RAID) Workstation (MLK) machines.

For detailed information on above media refer to the latest Experion PKS System Initialization Media Software Change Notice (SCN).

2.3.1 Generating the Configuration Files for Target Machine

2.3.1.1 Prerequisites

You need a standalone computer with CD/DVD ROM and Windows OS (Win2k3 or Win2k8 or Win XP or Win 7) to generate the configuration files for the target machine.

The configuration files generated on the standalone computer must be saved in a pen drive or on any removable disk as a backup. You need to use this configuration file along with Experion PKS R400 system Initialization Media on the target machine.

2.3.1.2 Generation of Configuration Files

Perform the following steps on the standalone computer to generate the configuration file for the target machine.

NOTE:

Acknowledge the user account control dialog box, if it appears. It is not necessary or mandatory for the user account control dialog box to appear during the installation process. This information is applicable for the remainder of this manual, unless explicitly stated otherwise.

1. Insert the Experion PKS R400 System Initialization media into the CD/DVD drive of the standalone computer (not the target computer).

The Honeywell- Experion PKS System Initialization Media dialog box appears.

Page 12: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 12 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-8 Experion PKS System Initialization Media Dialog box

2. Click Launch Setup.

3. Click Yes, id the User Account Control dialog box appears.

The Initializing Experion PKS System Installer... message appears.

The Experion PKS System Initialization Wizard appears.

Page 13: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 13 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-9 Experion PKS System Initialization R100.3 Dialog manager for generating Configuration file

4. Select Generate Configuration files.

5. Click Next.

NOTE:

If the configuration files are already generated for the target machine, select Modify existing configuration files. Click Browse to browse to the configuration files and select the InitMediaOptions.xml file. Click Next. The subsequent dialog boxes are displayed according to the selections made as per the configuration files. You can modify the selections if required.

The Platform Configuration dialog box appears.

Page 14: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 14 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-10 Experion PKS System Initialization R100.3 Dialog manager for Platform Configuration

6. Select the following in Platform Configuration:

From Choose Configuration, select Reinstall OS and Configure System in Platform Configuration.

Uncheck the Product Installation option.

NOTE: This check box must be unchecked since OS Installation need to be taken up first.

From Select Platform, select Workstation and select the Dell Model for the target machine from the drop-down list.

From Select Operating System, select Client and choose the Windows 7 Professional from drop-down list.

Click Next.

The Operating System Configuration dialog box appears.

Page 15: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 15 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-11 Experion PKS System Initialization R100.3 Dialog manager for OS Configuration

7. Select the following in the System Settings:

Select the Local Language from the drop-down list.

Select the Time Zone from the drop-down list appropriate to the geographical location where the system is used.

Type the Computer Name

Naming restrictions

The computer name must be 15 characters or less in length and should begin with an alphabetic character (“a to z” or “A to Z”) and cannot contain spaces or other non-standard characters.

All other nodes including non-redundant Servers Must Not end with the letters A or B.

Type the Company Name.

Type the Customer Name.

NOTE: For the Company Name and Customer Name do not use special characters.

Type the Workgroup Name.

8. In the Account and Password, enter the following details:

User Account Name (QCSAdmin)

Password (Hmxresult1#) and confirm the password.

Page 16: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 16 of 37

Honeywell Proprietary and Confidential DO NOT COPY

9. Uncheck the Microsoft Embedded COA (Certificate Of Authenticity) is not available on this platform check box. By doing this you need not enter the product key.

10. Click Next.

The Network and Input/Output Devices Configuration dialog box appears.

NOTE: For the systems with FTE connections ensure to install Intel Pro 1000 PT Dual Port Network adapter.

Figure 2-12 Experion PKS System Initialization R100.3 Dialog manager for Network and I/O device Configuration

11. For configuring the systems with FTE, proceed with Step 13.

12. For configuring the system with Ethernet, select the Network Type as Ethernet, select the No. of Adapters as One from the drop-down list and Network Link Speed as 100 mbps Full Duplex.

13. In the Network Configuration select the following:

Select the Network Type as FTE for systems with FTE

Select No. of Adapters as Two for systems with FTE

The configuration of a network port can be changed by selecting it and clicking the TCP/IP Properties for NIC button.

14. In the I/O details ensure the following settings are selected:

Single monitor option.

1280x1024 resolution option.

15. In the FTE Configuration

Type the Multicast Address

Page 17: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 17 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Type the Device Index

Type the UDP Source Port

Type UDP Destination Port

Provide a Friendly Name

NOTE: For detailed information about FTE installation and configuration refer to Fault Tolerant Ethernet Installation and Service Guide - FE05-400 (Document ID: EP-DSX256).

16. Click Next.

17. Read through the Confirmation Configuration Summary details, and click Save Config.Files.

Figure 2-13 Experion PKS System Initialization R100.3 Dialog manager Confirmation box

To save the config files, browse through one of the following options.

a. You can either use USB flash drive, or local hard disk to save the configuration files to be used on this computer for future use. OR

b. Save the generated configuration files in a separate folder at the root of the C drive, floppy drive, or USB drive.

18. Click OK.

The Experion PKS System Initialization dialog box appears indicating that Configuration files are saved successfully.

Page 18: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 18 of 37

Honeywell Proprietary and Confidential DO NOT COPY

19. Click OK.

20. Click Finish.

21. Read the instructions on the Honeywell Experion PKS System Initialization R100.3 - DialogManager

22. Click OK.

23. Close the Honeywell- Experion PKS System Initialization window.

2.3.2 Installing the Operating System on the Target Machine using Experion PKS R400 System Initialization Media

1. In the target machine, insert Experion PKS R400 System Initialization media, connect the USB flash drive that has the configuration file created for the target machine in Section 2.3.1 and re-start the computer.

NOTE: Ensure that the USB drive containing the configuration files generated for the target machine is connected before you re-start the computer to avoid any removable disc detection.

2. Watch the monitor while it restarts and press any key when you see the message Press any key to boot from CD or DVD.

Page 19: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 19 of 37

Honeywell Proprietary and Confidential DO NOT COPY

The Windows is loading files message appears.

The Experion PKS System Initialization Pre-Install Utility Window appears.

Figure 2-14 Experion PKS System Initialization Pre-Installation Utility Dialog Box

3. Click Browse and select the path where the configuration file is present.

4. Select InitMediaOptions.xml files.

5. Click Open.

Page 20: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 20 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-15 Experion PKS System Initialization Pre-Installation Utility to browse configuration file

6. Click Next.

The Experion PKS System Initialization Pre-Install Utility dialog box appears.

Figure 2-16 Experion PKS System Initialization Pre-Installation Utility to provide configuration details

7. In the Configuration details, select the following:

Partitions count as Two from the drop-down list.

Type the size of Primary partition as 70.

8. Select DVD as the appropriate location for installation media.

9. Click Next.

The Notice of Licensed Software dialog box appears.

Page 21: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 21 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-17 Experion PKS System Initialization Pre-Installation Utility showing Honeywell end user License Agreement

10. Read the license agreement and select I accept the terms in the license agreement.

11. Click Install.

A warning message appears indicating that the disk contents and partition will be deleted.

12. Click Yes to continue.

13. The Experion PKS System initialization preparing for Operating System installation dialog box appears.

A message appears prompting to insert the Windows 7 Reinstallation DVD.

14. Remove the Experion PKS System Initialization media and insert the HPS operating system reinstallation media for Windows 7.

15. Click OK.

The Installing Windows…dialog box displays the status of the Operating System installation.

16. During the Operating System installation, your computer restarts several times.

17. After the Operating System installation is completed, a message appears prompting you to insert the Experion PKS System Initialization R100.3 DVD.

Page 22: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 22 of 37

Honeywell Proprietary and Confidential DO NOT COPY

18. Remove the Windows 7 Reinstallation media and insert the Experion PKS System

Initialization R100.3 media and click OK.

The Initializing Experion PKS System Installer... message appears.

19. After the initial personalized settings are completed, The Experion PKS-Status Display dialog box appears, displaying the status of the Operating System Configuration.

A message appears in the Experion PKS-Status Display dialog box confirming the Experion PKS System Initialization Installation is completed successfully.

20. Click OK to restart the system.

21. After the system restarts, login to the machine as QCSAdmin and verify the OS installation.

2.4 Creating Boot media

Windows PE Boot media is needed to run the Norton ghost application on this RAE node for creating its Ghost image (GHO file). You can use the same media to restore Ghost Images that are taken already.

NOTE: Use the computer which has Windows Operating System and the CD/DVD Burning Software installed for creating the Boot Media.

NOTE: Refer the Ghost Backup for Da Vinci and MXProLine Systems user guide (46027201) for more details on using Norton Ghost on RAE node.

Use the burning software to burn a Boot Media CD from the Production DVD_124\OSDeployment\01000936_REVC_winpe.iso image.

2.5 Monitor Connection settings

NVS295 Display adapter card consists of two DP ports. When you set up the dual video configurations, the Lower DP port is set as the Primary Video and the Upper DP port is set as the Secondary Video.

A DP to DVI-D adapter converter can be used to convert the DP signal of NVS295 to DVI-D signal for monitor. For this purpose, the monitor must support the DVI-D signal and must have an appropriate signal cable.

Page 23: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 23 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-18 Monitor connection settings for NVIDIA Quadro NVS295

A DP to VGA adapter converter can be used to convert the DP signal of NVS295 to VGA signal for monitor. The monitor must support the VGA signal and must have an appropriate signal cable.

2.6 Display Properties configuration

This section provides the procedure to configure the display properties.

2.6.1 Display Properties Configuration for Single Monitor

To configure the display properties for a computer using a single monitor

1. Right-click on the desktop, and then click Personalize from the shortcut menu.

The Personalization dialog box appears.

Page 24: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 24 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-19 Personalization Dialog box showing Display configuration settings

2. Select Display under See also.

The Display dialog box appears.

Figure 2-20 Monitor Display Dialog box showing Display settings

3. Select Smaller-100% (default) option.

4. Click Change display settings.

Page 25: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 25 of 37

Honeywell Proprietary and Confidential DO NOT COPY

The Screen Resolution dialog box appears.

Figure 2-21 Screen resolution settings Dialog box

5. Under Resolution, move the Slider to set a screen resolution of 1280x1024 in drop-down list.

6. Click Advanced settings.

The Generic PnP Monitor and NVIDIA Quadro NVS 295 Properties dialog box appears.

Figure 2-22 Monitor and NVIDIA Quadro NVS Properties showing Screen Refresh rate and color Settings

Page 26: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 26 of 37

Honeywell Proprietary and Confidential DO NOT COPY

7. Click the Monitor tab.

8. Under Monitor settings, set the Screen refresh rate based on type of monitor you are using, as follows:

For LCD Monitors – 60 Hertz.

For non-LCD Monitors – 75 Hertz

9. Under Colors, select High Color (16-bit).

10. Click Apply.

The Display Settings message appears, prompting you to keep the display settings you have configured.

11. Click Yes.

12. Click OK to save the monitor settings and close the dialog box.

13. Click OK to close the Screen Resolution dialog box.

14. Close the Display dialog box.

2.6.2 Display Properties Configuration for Dual Monitor

When T5500 System is used with dual monitors, first configure the display settings for a single monitor, see section 2.6.1, and then configure the display settings for the second monitor.

To configure the Display settings for the second monitor

1. Connect both the Monitors to the NVIDIA Quadro NVS 295 card.

2. Right-click on the desktop, and then click Personalize from the shortcut menu.

The Personalization dialog box appears.

Page 27: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 27 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-23 Personalization Dialog box showing Display configuration settings

3. Select Display under See also.

The Display dialog box appears.

Figure 2-24 Monitor Display Dialog box showing Display settings

4. Select Smaller-100% (default) option.

5. Click Change display settings.

The Screen Resolution dialog box appears.

Page 28: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 28 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-25 Screen resolution and monitor settings Dialog box

6. Under Display Select the Second Monitor.

7. Under Resolution, move the Slider to set a screen resolution of 1280x1024 in drop-down list.

8. Under Multiple displays select Extend these displays.

9. Click Advanced settings.

The Generic PnP Monitor and NVIDIA Quadro NVS 295 Properties dialog box appears.

Page 29: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 29 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-26 Monitor and NVIDIA Quadro NVS Properties showing Screen Refresh rate and color Settings

10. Click the Monitor tab.

11. Under Monitor settings, set the Screen refresh rate based on type of monitor you are using, as follows:

For LCD Monitors – 60 Hertz.

For non-LCD Monitors – 75 Hertz

12. Under Colors, select High Color (16-bit).

13. Click Apply.

The Display Settings message appears, prompting you to keep the display settings you have configured.

14. Click Yes.

15. Click OK to save the monitor settings and close the dialog box.

16. Click OK to close the Screen Resolution dialog box.

17. Close the Display dialog box.

Page 30: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 30 of 37

Honeywell Proprietary and Confidential DO NOT COPY

2.7 Roxio Burning Software

2.7.1 Installation of Roxio Burning Software

Honeywell recommends to install Roxio Burning Software in your computer.

To install the Roxio Burning Software

1. Insert the Roxio Burning Software media provided along with the T5500 machine into the CD/DVD ROM-drive.

2. The Autorun setup wizard appears.

The Welcome to the Setup Wizard for Roxio Creator DE 10.3 Setup appears.

Figure 2-27 Roxio Creation DE 10.3 Setup Dialog box

3. Click Next.

The License Agreement dialog box appears.

Page 31: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 31 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-28 Roxio Creation DE 10.3 Setup Dialog box showing License Agreement

4. Read the License and Agreement, and then click I accept the terms in the License Agreement.

5. Click Next.

The Customer Information dialog box appears.

6. Click Next.

The Choose Setup Type dialog box appears.

Figure 2-29 Roxio Creation DE 10.3 Setup Dialog box showing Installation Setup Type

7. Click Custom.

8. Click Next.

The Install Location dialog box appears.

Page 32: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 32 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-30 Roxio Creation DE 10.3 Setup Dialog box showing Install Location

9. Click Next.

The Custom Setup dialog box appears.

Figure 2-31 Roxio Creation DE 10.3 Setup Dialog box showing Custom Setup

10. By default all the features that will be installed are selected. However, you must clear the check boxes for the features that must not be installed, and ensure to select ONLY the following features:

Roxio Creator Tools

Roxio Creator Data

Roxio Creator Copy

11. Click Next.

Page 33: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 33 of 37

Honeywell Proprietary and Confidential DO NOT COPY

The Ready to Install dialog box appears.

12. Click Install.

After the installation is complete, the Roxio Creator DE 10.3 Setup complete wizard dialog box appears.

Figure 2-32 Roxio Creation DE 10.3 Setup Dialog box showing Setup Wizard completed

13. Click Finish.

A message appears, prompting you to restart the computer.

14. Click Yes. The computer will restart.

2.7.2 Roxio Burning Software Settings

To configure Roxio Burning Software settings

1. Choose Start > Programs > Roxio Creator DE > Home.

The Roxio Product Registration dialog box appears.

2. Click Cancel.

A message appears, prompting you to confirm the cancellation of the product registration.

Page 34: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 34 of 37

Honeywell Proprietary and Confidential DO NOT COPY

NOTE: This message may be displayed in different languages, depending on your regional settings.

3. Select Don’t Show Me This Again.

4. Click OK.

The Creator DE 10.3 window appears.

Figure 2-33 Roxio Creation DE 10.3 Dialog box

5. On the Tools menu, click Options.

The Options dialog box appears.

Figure 2-34 Roxio Creation DE 10.3 setting in the Option Dialog box

6. Select General in the left pane.

The General setting details are displayed in the right pane.

7. Under Startup, clear the Check for updates check box.

8. Select Data and Backup in the left pane.

Page 35: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 35 of 37

Honeywell Proprietary and Confidential DO NOT COPY

The Data setting details are displayed in the right pane.

Figure 2-35 Roxio Creation DE 10.3 setting in the Option Dialog box

9. Under CD Recording Options, perform the following:

In the Type list, select Disc at Once (DAO), Closed from drop-down list.

In the Mode list, select Mode 1 from drop-down list.

In the File System list, select ISO+Joliet (102 character file names) from drop-down list.

10. Under Write-Once DVD Compatibility, select I only need to use discs for one recording option.

11. Click OK to close the Options dialog box.

12. Close the Creator DE 10.3 window.

2.8 Installing the RAE

For installing RAE R600 on this Operator Station, refer to Real-Time Application Environment (RAE) R600 with Experion R400.2 Release and Installation Notes p/n 6510020334.

Page 36: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 36 of 37

Honeywell Proprietary and Confidential DO NOT COPY

3 Additional Information

This section provides additional information related to Operating System loading after major hardware recovery such as Mother Board failure.

3.1 BIOS Update utility

The BIOS Update utility selects Dell’s or Honeywell’s custom BIOS to support/protect operating system activation. Honeywell’s custom BIOS files are derived from generic Dell BIOS files and are mandatory to complete automatic activation of the operating system for platforms that are installed using Honeywell OEM embedded operating systems.

ATTENTION:

The BIOS Update utility updates the BIOS either to a new version or to any of the previous versions. This is a new feature introduced in Experion PKS System Initialization R100.3 onwards.

CAUTION: You are recommended to use the BIOS Update utility only in case of motherboard failure or motherboard replacement.

The following table lists the platform names and the model numbers with which the BIOS Update utility must be used.

Platform Part Number

T5500 6543100031

6543100030

In case of motherboard failure, below steps needs to be carried out in order to bring back the server to operation:

1. Replace the motherboard.

2. Complete the motherboard installation.

3. Switch on the platform.

4. Run the BIOS Update utility by referring Section 3.1.1 Installing the appropriate BIOS on R400.x platform.

3.1.1 Installing the appropriate BIOS on R400.x platform

CAUTION: Before starting the BIOS Update utility installation, save all data and close all windows. After the installation platform needs a restart.

Page 37: PRODUCTION OF QCS OPERATOR STATION ON …Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7 USING EXPPLUS Document # 6510030098 REV 02 Where Used: 09588010 Page 6 of 37

Document Title: PRODUCTION OF QCS OPERATOR STATION ON WINDOWS 7

USING EXPPLUS

Document # 6510030098

REV 02

Where Used: 09588010 Page 37 of 37

Honeywell Proprietary and Confidential DO NOT COPY

Perform the following steps to run the BIOS Update utility on R400.x platforms.

1. Log on to the platform with administrator privileges.

2. Insert Experion PKS System Initialization R100.3 (or Later) media into DVD drive.

3. Browse to <root>\webpage\autorun.htm path.

4. Double-click autorun.htm

The Experion PKS System Initialization On-media documentation dialog box is displayed.

5. In the left pane, click BIOS

The BIOS Minimum Requirements screen is displayed in the right pane.

6. In the right pane, click platformname.exe from the BIOS upgrade application column.

For example, if you are upgrading BIOS version for the R710 platform, click R710.exe file.

7. Save the platformname.exe to your local folder.

8. Browse to the folder containing the installer and double-click WinZipSelfExtractor-<platform name.exe>

9. Click Allow and click Setup.

The BIOS Update dialog box is displayed that contains information about the installed BIOS version and the latest custom BIOS version.

ATTENTION:

The installed BIOS version and the package version displayed in the BIOS Update dialog box varies depending on the server or workstation on which you are performing the installation.

10. Click Yes to continue with the BIOS update installation.

11. Click OK to restart the platform after completing the installation.

CAUTION: Do not click Cancel on the WinZip Self Extractor-<platform name.exe> dialog box or close the WinZip Self Extractor-<platform name.exe> dialog box during installation.

The BIOS update occurs immediately after the platform is restarted.

Information about the BIOS modification is displayed on the screen.

Subsequently, the installed BIOS version is displayed in the Power On Self Test (POST) screen. You can also check the BIOS version by pressing F2 once the POST screen closes.