products catalog - neodent 2011

164
Technical Guidance Value your job Morse Taper Implants Ti External Hex Implants II Plus Internal Hex Implants Zygomatic Implants Surgical Techniques Bone Grafting and Orthodontic Anchorage Kits Neodent Surgical Instruments 14 18 26 58 84 102 110 128 136 154

Upload: neodent

Post on 21-Mar-2016

341 views

Category:

Documents


21 download

DESCRIPTION

Products Catalog - Neodent 2011

TRANSCRIPT

Page 1: Products Catalog - Neodent 2011

1

Technical Guidance

Value your job

Morse Taper Implants

Ti External Hex Implants

II Plus Internal Hex Implants

Zygomatic Implants

Surgical Techniques

Bone Grafting and Orthodontic Anchorage

Kits Neodent

Surgical Instruments

14

18

26

58

84

102

110

128

136

154

Page 2: Products Catalog - Neodent 2011

22

All Neodent efforts aim to provide what is best for you. Such thinking is part of our mission, and, therefore, we hope to serve you forever, and getting better. Neodent’s commitment is to be 100% for you. Being a company 100% for you reflects in our service, in our business relationships, in our product development, in our events and in our scientific research. Whenever you see a Neodent advisor, a collaborator or even a solution for our company with the brand of 100% for you, know that the meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus all the support necessary to further enrich

Much more than dental implants, a

company made100% for you.

meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus

Page 3: Products Catalog - Neodent 2011

3

Imagine a manufacturing process beginning

from scratch. Based in science and research,

a specialist analyzes the function, the format,

details, and the materials with which the implant

or the component will be made. All of it with lots

of studies and dedication. When this step is

completed, about 20% of the whole work has

been finalized.

Now, it is time to transform

raw-materials into a refined

surgical material, something

that is possible due to the high

industrial technology and also

because of the involvement of

outstanding professionals with

the project. Now, 50% of the whole

project is completed.

Now it is the time when the strict quality control is

applied, including sterilizing, and the withdrawal

of any errors and imperfections. Approximately

75% of the project is now completed. Then,

products are packed and sent to logistics, to our

advisors, and subsequently to you. 100%. The

work is done!

This is the reason why 100% is so important

for us. All steps, from the implant’s concept

through to delivery, are paramount

in order to maintain Neodent’s

quality assurance. We combine

all our efforts to achieve such

percentage, so that you can

be served well, having reliable

products available and all the

support you need to enhance

even further your own talents.

This catalog, in line with any other

of Neodent’s solutions, is the result of 100%

of commitment and dedication from us to

professionals like you.

All Neodent efforts aim to provide what is best for you. Such thinking is part of our mission, and, therefore, we hope to serve you forever, and getting better. Neodent’s commitment is to be 100% for you. Being a company 100% for you reflects in our service, in our business relationships, in our product development, in our events and in our scientific research. Whenever you see a Neodent advisor, a collaborator or even a solution for our company with the brand of 100% for you, know that the meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus all the support necessary to further enrich

meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus

Page 4: Products Catalog - Neodent 2011

4

In order to guarantee our innovative potential and our

high technology, in 2009 we inaugurated our New

Industrial Complex, featuring 12.000m2, occupying a plot

of land measuring 50.000m2, expanding our production

capacity like no other one in Latin America. The Complex

is equipped with automated machinery, which runs during

3 non-stop shifts. Thanks to such manufacturing potential,

Neodent is also the only Latin American company in its

segment capable of manufacturing its instruments in-

house. The whole project was planned so as to optimize

production and to allow our structure to irradiate our

company’s fundamental values: advances in technology,

respect for human beings and socio-environmental

responsibility.

QUALITY CONTROL

CLEAN ROOM

INSTRUMENTS PRODUCTION

The Industry

PACKAGE

Page 5: Products Catalog - Neodent 2011

5

Apart from counting on the best and most modern equipments, the

Industrial Complex has an integrated Materials Laboratory (LIM),

aimed directly at research, development and quality control. This Lab

provides: Scanning Electron Microscope (MEV), which guarantees

quality starting from raw-materials and up to the finishing of the products; mechanic and metallographic

tests that assess the long term mechanical endurance, and also allow the micro-structural analysis of

all products. All of it results in excellence for you, our client who gives us your trust and who take our

name into your consulting room.

TRI-DIMENSIONAL CONTROL

PRODUCTION

MECHANICAL TESTS

ROBOTICS

Continuous Development and Quality Control

5

SCANNINGELECTRON

MICROSCOPE

MECHANICAL TESTS

Page 6: Products Catalog - Neodent 2011

6

The respect to human standards is a principle trait in

the architectural design of the New Industrial Complex,

highlighted by the preference for naturally lit environment

and of the use of materials and technologies that provide

greater thermoacoustic comfort. Now, our employees

have much more infrastructure and ergonomy for their

daily activities. We also have a fully-equipped restaurant

visually integrated into the grove, which attends to the

necessities of the employees and visitors, including

during the diverse events promoted. Concerned with

constant training, we constructed a spacious auditorium

to promote the transmission of knowledge, one of the

important pillars of our essence. Besides intellectual

development, encouragement towards sport is also a

priority: sport courts, a golf course, football and wood

forest for hiking. These values are the base of a strong

trademark that focuses on the people and works for their

wellbeing.

Respect to human standards

AUDITORIUM: CONSTANT PROFESSIONAL TRAINING

MULTI-PURPOSE COURTS

GAMES ROOM

RESTAURANT

Page 7: Products Catalog - Neodent 2011

7

Starting with the selective garbage collection, up to the treatment of the residual

waters at our Effluents Treatment Station, we perform continuous monitoring

of environmental issues, observing the applicable environmental and sanitation

regulations. When we conceived our new Industrial Complex, we have adopted

social and environmental solutions that are efficient, respecting the needs of

our associates, and reinforcing the image of the company as a reference icon in

environmentally correct actions.

Environment

EFFLUENTS TREATMENT STATION

WATER RETURNED TO THE ENVIRONMENT AFTER TREATMENT

PREFERENCE FOR NATURAL LIGHTING

Page 8: Products Catalog - Neodent 2011

8

MULTI-DISCIPLINARY LABORATORY

BLUE CLINIC

We count on the scientific support of ILAPEO – The Latin

American Institute of Research and Dental Education -, a

center of excellence in research, advances and innovations

in the clinical practice of dentistry. An institute made up of

professionals, professors and researchers of the highest level

of knowledge who offer post-graduate courses, such as

specialization and master’s degree, recognized by CFO, MEC

and CAPES.

RECEPTION

LIBRARY

AUDITORIUM

Page 9: Products Catalog - Neodent 2011

9

ContactWhenever you need, you can count on

our different communication channels:

•www.neodent.com.br

Besides our industrial and commercial headquarters

located in Curitiba (PR – Brazil), we count with ten branches,

located in the cities of Sao Paulo, Bauru, Rio de Janeiro, Belo

Horizonte, Porto Alegre, Goiania, Brasilia, Londrina, Recife

and Vitoria. Also, eight authorized distributors extend our

network into seven different Brazilian states (Amazonas,

Bahia, Mato Grosso, Mato Grosso do Sul, Para, Santa Catarina

and Tocantins), apart from our overseas branches located

in Portugal and in the United States. Our international

distribution network reaches thirteen other countries,

namely Argentina, Bolivia, Chile, Colombia, Ecuador, Spain,

Italy, Lebanon, Paraguay, Peru, Dominican Republic, Taiwan

and Venezuela.

A globally renowned company, made

100% for you.

Page 10: Products Catalog - Neodent 2011

10

The Neoshape CAD/CAM system allows the selection of several materials, such as Zirconia, Cobalt-Chromium,

Titanium and Acrylic, highlighting also the Lithium Disilicate.

The 3shape scanner is the first step for use of the Neoshape system, having as one of its differentials the precision of laser scanning. With it, the Prosthesis Technician can digitalize the plaster models or moldings, and use a simplified 3D modeling software to create parts in a simple and intuitive way.The scanner is sold in Brazil by Neodent, under its partnership with 3shape, a Danish company that is internationally renowned for its 3D scanning technology and quality. The D700 scanner provides micro-metric precision, as it performs a laser reading in 5 different planes, with no human intervention. Professionals who purchase the system can rely on world-class technical support, provided by the company, and also with all technical information needed to properly operate the product.

The Dental Designer software is very flexible and intuitive. Its tools are simple, and allow

the manipulation of the drawings of prosthetic structures, quickly and efficiently.

The software also allows customized anatomic adjustments, such as: spacing for cementing,

coping thickness, adding or reducing the virtual polishing, customization of abutments, among many other possibilities. As the whole

planning occurs virtually, the waste of time and materials is reduced.

PARTNERSHIP BETWEEN NEODENT AND 3SHAPE

DENTAL DESIGNER SOFTWARE

The Dental Designer software is very flexible and intuitive. Its tools are simple, and allow

the manipulation of the drawings of prosthetic

The software also allows customized anatomic adjustments, such as: spacing for cementing,

virtual polishing, customization of abutments, among many other possibilities. As the whole

planning occurs virtually, the waste of time and

CAD CAM SYSTEM

Page 11: Products Catalog - Neodent 2011

11

It also allows micrometric adjustments, optimizes the production time, 3D virtual polishing and laser scanning

technology.

The milling process begins after the virtual image (previously designed by the prosthesis technician using the Dental Designer software) is forwarded to the CAM software, which will mathematically determine the angles and the axis to be worked on the material, in order to reach a result absolutely identical to what was designed.

Neodent has established a partnership with Ivoclar Vivadent, and with it will bring to the Brazilian market a new option of material for the fabrication of customized prosthesis.It is the Lithium Disilicate (LS2), the E-max® CAD, a material that combines resistance, esthetics and ease of use.

NEODENT’S MILLING CENTER

PARTNERSHIP BETWEEN NEODENT AND IVOCLAR

Cobalt-ChromiumZirconia

The milling process begins after the virtual image (previously designed by the prosthesis technician using the Dental Designer software) is forwarded to the CAM software, which will mathematically determine the angles and the axis to be worked on the material, in order to reach a result absolutely identical to what was

NEODENT’S MILLING CENTER

AVAILABLE MATERIALS:

- Cobalt-Chromium: ideal for metalloceramics prosthesis.- Titanium: material recommended for infrastructure of hybrid prosthesis.- Zirconia: Aesthetics, high resistance, biocompatibility. - E-max® CAD: Translucent, resistance, esthetics and easy to use.

Page 12: Products Catalog - Neodent 2011

12

Following years of intense researches and development of

new technologies, Neodent has achieved the most modern

and current techniques for the surface treatment of implants:

the Neoporos Surface.

The NeoPoros surface is obtained from the concept of blasting

with abrasive particles, which has automated controls for

speed, direction, pressure and size of the particles that

collide with the implant. With that, we create craters at the

implant’s surface using oxides of controlled granularity. Next,

the surface is leveled using the acid subtraction technique.

Several scientific researches were performed, attesting

the efficiency of the bio-contact quality between bone and

implant, with the NeoPoros surface.

Electronic microscopes of the Neoporos Surface in amplifications of 2000X

and 5000X.

Surface

Continuous Evolution

and Safety Assurance

Controlled roughness to guarantee the size of the pores between 2.5 and 5.0µm throughout the entire implant surface.

Page 13: Products Catalog - Neodent 2011

13

Bone crest formed over a cervical portion of the Morse taper implants

with Neoporos surface after a period of osseointegration.

Direct contact of the bone to the implant, showing osteogenesis by contact and the osseous induction potential of Neoporos Surface.

Histological study of the bone tissue response

of Neodent implants with Neoporos Surface.

Page 14: Products Catalog - Neodent 2011

1414

Page 15: Products Catalog - Neodent 2011

1515

Technical Guidance

Page 16: Products Catalog - Neodent 2011

16

CorticalImplant Apex

DriveImplant Apex

IMPLANT INDICATION TABLE

Bone type I Bone type II Bone type III Bone type IV

In accordance with the bone classification of Lekholm and Zard (1985).

NEODENT IMPLANTS APEX

AlvimImplant Apex

EXImplant Apex

Morse Taper

Morse Taper

Morse Taper

Cortical with Mount

With Mount

MEDULLAR

Page 17: Products Catalog - Neodent 2011

17

CONNECTIONS AND TORQUES

20N.cm

20N.cm

20N.cm

20N.cm

10N.cm

20N.cm

Conical Abutment II Plus and Mini Abutment II Plus

Conical Abutment II Plus Angled

Universal Post and Angled II Plus

INT

ERN

AL

HEX

UCLA II Plus

Mini Ball Attachment

Cylinders

0.9 1.2 1.6 Prosthetic Abutments

Conical Abutment (Ø 4.3) and Slim Fit (Ø 4.3) 20N.cm

20N.cm

20N.cm

20N.cm

32N.cm

32N.cm

32N.cm

20N.cm

32N.cm

10N.cm

Mini Conical Abutment (Ø 3.3 and Ø 4.3)

Conical Abutment (Ø 5.0)

Mini Abutment Slim Fit (Ø 5.0)

Mini Abutment Slim Fit (Ø 4.1)

Angled Mini Conical Abutment (Ø 4.1)

Universal Post SF, Personalizable and Angled

UCLA (Ø 3.3; Ø 4.1; Ø 4.3; Ø 5.0)

EX

TERN

AL

HEX

Mini Ball Attachment

Cylinders

SELECTION OF PROSTHETIC COMPONENTS ACCORDINGTO THE ABUTMENT/IMPLANT INTERFACE

Multiple Prosthesis Multiple Prosthesis

Multiple ProsthesisMultiple Prosthesis

A. Overdenture Abutment B. Directly on the Implant

Working manner

Single Prosthesis

Single Prosthesis

Single Prosthesis

Single Prosthesis

Typ

e o

f p

rost

hesi

s 1.Screw-retained

2. Cemented

•Mini Conical Abutment •Transepithelial Abutment

•Micro abutment

•Universal Post•Personalizable Post

•Conical Abutment•CM Abutment

•Anatomical Post•Universal Post•Personalizable Post

•UCLA

•UCLA

32N.cm

15N.cm

32N.cm

10N.cm

32N.cm

32N.cm

15N.cm

15N.cm

15N.cm

CM Mini Conical Abutment, WS and CM Micro Abutment

CM Abutment and WS

CM Angled Mini Abutment and Exact

Universal Post CM and WS

Anatomic Post CM and Exact

Universal Post CM Through Screw

MO

RS

E T

APE

R

Cylinders

Mini Ball Attachment

Universal Post CM and Angled Exact

Page 18: Products Catalog - Neodent 2011

18

Value your work

Page 19: Products Catalog - Neodent 2011

19

The cylinders and UCLAs for overcasting

present with perfect adaption and perfect

fitting, following international quality

regulations and standards. The dimensional

tolerance between implants, intermediates

and manufactured belts, as well as the

individual analysis of each piece, are the

differences of these components that pass

through strict industrial quality control at a

micrometric level.

All of these products are manufactured using

the latest equipment, ensuring the best

adaption. Castable polymers sleeves fitted

over the metal bases are replaced with metal

after the overcasting process, thus the pre-

fabricated metalic base has a higher fusion

temperature than the metal to be overcast.

Such polymers facilitate the finishing process

of the parts and ensure the overlapping of

the overcast metal to the pre-manufactured

metal. However, the casting process does

not follow the same quality control that the

manufacturing process does, therefore, the

dental technician should often check for

the absence of positive metallic porosities

in the screw passage tube. Therefore, the

overcastting technique maintains the quality

of the fittings among the guaranteed parts

from the factory and enables the design and

individualization of the

infrastructure, to allow additional material on

the manufactured base to hold its shape.

The use of these products should be

carried out in accordance with the handling

instructions as described in the manual, as

well as in the instructions provided by the

various manufacturers of overcasting alloys.

Thus, the oral rehabilitation team can ensure

success for the technique more safely. For

best results, always use the entire

sequence of Neodent® products (analogues,

abutments, screws, transfer copings, and

protectors).

Believing in the importance of allowing the

customer to choose the product, we offer

different metallic alloy cylinders with pre-

fabricated belts bases for overcasting.:

- Cobalt-Chromium.

- Gold (Gold Alloy).

Page 20: Products Catalog - Neodent 2011

20

HANDLING OF

CYLINDERS FOR OVERCASTING

Regardless of the type of alloy chosen,

the dental technician should take special

care when handling the pre-fabricated

cylinders, thus improving the quality

of the overcasting and the ceramic

application processes.

1. Waxing:

The edges waxing of the component

cannot overrun the borders that come

into contact with the implant or the

prosthetic component (metallic base

of cylinder), guaranteed to preserve

and adapt the industrial quality control

process.

2. Overcasting:

The prosthetic cylinders are made

non-sterile and are suitable for single

use. The metal bases are manufactured

with alloys that have a high fusion

temperature compared to the metal

that is to be overcast. In cases where the

metal for overcasting has a higher fusion

temperature than the manufactured

parts, they will deform due to high

temperatures. However, if the metal due

to be overcast has a fusion temperature

much lower than the metal in the

base, bonding may occur between the

parts and the base of the component,

which could result in the release of the

infrastructure.

All the cylinders with pre-fabricated

bases are evaluated one by one, from

the reception of the raw material, which

is analyzed before production, to its final

package, ensuring quality throughout

the entire manufacturing process.

3. Finishing and metal polishing:

The disembedding of the casted object

at the coating must be done carefully,

avoiding abrasive jets blasts, which

may alter the prefabricated surface.

It is recommended to machining the

final infrastructure at a low rotation

with the use of refrigeration, with

specific drills for metal. Both of the

areas corresponding to the stop of

the head of the prosthetic screws

inside the passing tube must maintain

their full original shape, without the

presence of positive metal porosities

or deformations. The edges of the

cylinders must be covered by polishing

protectors during the polishing and

the finishing of the infrastructure.

Corrosive materials, such as those

with iron particles, should also not be

used. Very strict criteria should be

applied, because flaws in overcasting

procedure may cause the loss of the

entire work.

4. Ceramic application:

The porcelain choice should

correspond to the used alloy (CoCr,

Tilite or Gold). The ceramic cannot be

applied directly over the manufactured

bases of the cylinder, so that the

waxing and the overcasting ensure a

complete covering of the infrastructure

area in which the ceramic is to be

applied.

Page 21: Products Catalog - Neodent 2011

21

COBALT-CHROMIUM LINE (CoCr)

The cylinders for overcasting with

prefabricated bases of Cobalt-Chromium

(CoCr) have a high resistance to water

corrosion and elevated mechanical resistance

to withstand occlusal loads. This is an alloy

that has a high biocompatibility and is easy

to use by the technician, with an excellent

acceptance of ceramic application for CoCr.

In addition, this alloy is compatible with

one of the strongest trends in healthcare

worldwide in its absence of Nickel in its

chemical composition, resulting in lower risks

of allergenic reactions when in contact with

living tissues, such as the oral mucosa.

Several cylinders and UCLAs are available

in this alloy, and from the customised

infrastructures of the Neoshape line. Note

the options and mechanical characteristics

(rotational or antirotational) for each case, as

well as the sequence of products found in this

catalogue.

Important informations:

• Melting range: 1.287 to 1.378°C (2.348 to

2.512 °F);

• Density: 8,28 g/cm3;• Coefficient of thermal expansion: 14,2µm/K

(600°C).

An alloy compatible for the overcasting

procedure that is in accordance with

regulations ASTM F1537, ASTM F799, ISO

5832-12 or ISO 5832-4 should be chosen.

The thickness of the metal after overcasting

must be at least 0.5 mm, and can be reduced

during manufacturing and finishing by up to

0.3 mm.

Welding must be done in the range of 1.120 to

1.150°C (2.048 to 2.102 °F)

21

The chemical composition of the high fusion CoCr alloy

follows is in accordance to the international regulation

ASTM F-1537, by following this chemical composition:

CHEMICAL ELEMENT Composition (%)

Cobalt 58 to 69

Chromium 26 to 30

Molybdenum 5 to 7

Nitrogen Max. 0,25

Carbon Max. 0,14

Page 22: Products Catalog - Neodent 2011

22

ALUMINA LINE

In line with global aesthetic

trends, the following cylinders

are available for the sequence

of Universal Posts made of

Aluminum Oxide: The Alumina line,

indicated to cemented unitary

prosthesis without metal, has the

following characteristics:

• Superior aesthetics and excellent

biocompatibility;

• Absence of metallic margin;

• Best translucency;

• Security on marginal adaptation;

• Effective Mechanical properties;

• No possibility of thermal

conductivity or oxidation;

• Excellent cost/ benefit;

• Technical procedures

widely known by the DENTAL

TECHNICIANS.

Note the sequence of procedures

for utilization of this product found

in this catalogue.

Aluminized feldspathic ceramics

are suitable for the application

of these Alumina cylinders. Some

situations require the customization

of the cylinder in order to avoid

the excess of unsupported

feldspathic ceramics, as following

the manufacturer’s instructions

of the ceramics. For this, the

DENTAL TECHNICIAN must use

aluminized ceramics of margin

or reconstruction, fabricating the

final infrastructure before the

application of the porcelain.

Page 23: Products Catalog - Neodent 2011

23

GOLD LINE

Among the metallic alloys, the

cylinders for overcasting with pre-

fabricated bases in gold are to be

the first choice for the construction of

prosthetic infrastructures on dental

implants. Of all of the existing metallic

alloys for the manufacture of dental

prosthesis, none were better than

the gold alloys in relation to intraoral

survival time due to their following

characteristics:

• Excellent biocompatibility: no

cytotoxic potential (extraction test ISO

10993-5) or allergenic reaction (ISO

10993-10 maximized);

• Extremely low levels of corrosion

(according to regulation ISO/DIS

10271);

• Excellent mechanical properties;

• Reduction of friction coefficient

between parts;

• Increased pre-load of the prosthetic

screw.

From a technical point of view, this

is an alloy of easy handling for the

DENTAL TECHNICIAN, since it has an

optimal hardness, low capacity for

deformation and a white colouring,

which makes aesthetics easier. Its

high fusion temperature permits

overcasting with gold and semi-gold

alloys and results in complete safety

for the ceramic application.

Cylinders on mini abutments and

UCLAs are available in this alloy. Note

the sequence

of this product found in this catalogue.

Important informations:

• Melting range: 1.400 to 1490°C

(2.552 to 2.714 °F);

• Density: 17,5 g/cm3;• Coefficient of thermal expansion:

12,2µm/K (600°C).

The alloys must be chosen to be

compatible with the overcasting

procedure (gold or semigold) that

are in accordance with regulation ISO

9693 and ISO 22674..

The thickness of the metal after

overcastting should be at least 0.5

mm.

Welding must be done in the range of

800 to 890°C (1.472 to 1.634 °F).

The gold alloy with a high melting has the following chemical composition:

CHEMICAL ELEMENT Composition (%)

Gold 60

Palladium 20

Platinum 19

Iridium 1

Page 24: Products Catalog - Neodent 2011

24

CASTABLE LINE

A product line that gives to the

DENTAL TECHNICIANS complete

freedom to cast the infrastructure

with a metallic alloy of their choice,

directly over the implant platform or

abutment. Often, price is the decisive

factor in this choice. Therefore, the

adaptation quality to the implant

primarily depends on the care

in handling by the professional,

providing quality assurance of

prosthetic components with pre-

fabricated metallic base.

After casting, we suggest that you

always evaluate the adaptation of

the analogues prior to cementing the

crown.

The castable components are

available for all cylinders on

intermediary, Universal Posts and

UCLAs. Note the sequence of this

product found in this catalogue.

Page 25: Products Catalog - Neodent 2011

25

TITANIUM LINE

Among the more traditional alloy in

implantology, there is the Titanium,

conforming to regulation ASTM F136-

Ti6Al4V. Known as Titanium grade V,

it is widely used in the manufacture of

provisional prosthesis. The dentist or the

DPT can adapt resin crowns pre-fabricated

over the cylinders and can create

provisional crowns with perfect fitting

and security, or even create a provisional

crown directly over the cylinders, which

can be used in immediate loading

situations. The prosthetic components

in Titanium are provided sterile,

guaranteeing security and strengthening

our ethical commitment with you..

Pre-fabricated components in Titanium

must not be overcasted. Although

Titanium has a high fusion temperature

(approx 1680 ºC), the alloy undergoes

structural changes when subjected to high

temperatures. Therefore, metallic alloys

with Titanium base still remain a challenge

to the science of dental material.

The Titanium prosthetic components are

offered as cylinders for all intermediates

and implants, also as customized

infrastructures with the Neoshape line.

Note the mechanical characteristics

(rotational or anti-rotational) of each case

and the sequence of products found in this

catalogue.

Page 26: Products Catalog - Neodent 2011

2626

The implant with impermeable fitting that optimizes bacterial sealing and the health of peri-implant tissue.

•CM Abutment (single)•CM Mini Abutment

(multiple)•CM Angled Mini

Abutment 17° and 30° (multiple)

•CM Micro Abutment (multiple)

•CM Angled Universal Post 17° and 30°

•CM Universal Post Through Screw

•CM Universal Post (single body)

•Anatomical Post in Titanium

•CM Mini Ball Attachment •CM Micro Abutment•CM Mini Abutment•CM Angled Mini Conical

Abutment 17° and 30°•Cylinder and Distal Bar

Passive Fitting Technique•Castable Cylinder – Mini Abutment •Titanium Cylinder – Mini Abutment •Brass Cylinder – Mini Abutment

•WS Abutment (single)•Ws Mini Abutment

(multiple)•CM Transepithelial

Abutment (multiple)

•WS Universal Post with Through Screw •WS Mini Abutment (single)

Passive Fitting Technique•Castable Cylinder – Mini

Abutment •Titanium Cylinder – Mini

Abutment •Brass Cylinder – Mini Abutment

MORSE TAPER

MORSE TAPER WSZYGOMATIC CM

3.5, 3.75, 4.0, 4.3 and 5.0 mm

4.0, 5.0 and 6.0 mm

Screw-retained Prosthesis

Cemented Prosthesis Overdenture Protocol

Ø 2.5 mm

Ø 3.0 mm

Ø Implant

Ø Implant

MORSE TAPER

COMPONENTS INDICATION TABLE

Inte

rna

l Thre

ad

Ø 1

.8In

tern

al T

hrea

d Ø

1.8

Page 27: Products Catalog - Neodent 2011

2727

M o r s e T a p e r

• GAP reduced (impermeable fitting);

• Stable Anti-rotational fixing;

• High mechanical strength;

• Unique prosthetic interface, independent of the implant diameter;

• First system with Morse Taper fitting in Brazil;

• The CM angle and the internal thickness of the implant enable the

design of the screw thread to reach the cervical portion of the

implant;

• High resistance, comparable to implants with external hex with

regular platform;

•NeoPoros Surface.

Simplified installation with no mount.

Morse Taper Implants now with indexer.

New line of Exact components, specific for

CM Index Implants.

Each point at Installation Driver corresponds to one plane face of the indexer.

Page 28: Products Catalog - Neodent 2011

28

The hexagonal prosthetic index simplifies the

implant installation process, reduces surgical

time, increases the resistance to insertion torque

and allows dentists to install the prosthesis

already with a forecast for the positioning of

the crown regarding the implant, thus providing

even more safety, speed and flexibility to clinical

and laboratorial works.

CM Implantsnow with Prosthetic Index

The hexagonal prosthetic index simplifies the

implant installation process, reduces surgical

time, increases the resistance to insertion torque

and allows dentists to install the prosthesis

already with a forecast for the positioning of

the crown regarding the implant, thus providing

even more safety, speed and flexibility to clinical

and laboratorial works.

Capture and Transport of the Implant

Specific drivers to the hexagonal prosthetic

indexer in the implant, available for contra-

angle or ratchet, allow the capture of the

implants directly on the package.

The replacement of old mounts for these drivers

guarantees greater resistance to torque, more

faster and safety on procedures.

Drivers

The installation drivers have six markings

which match with the six faces of the hexagonal

prosthetic index of implant. At the installation

moment, one of these markings in driver should

be in vestibular position, facilitating thus the

posterior prosthetic procedure.

Page 29: Products Catalog - Neodent 2011

29

CM ExactLine

Versatility of Index Implant

The CM implants with prosthetic index remain

compatible with the entire line of CM prosthetic

components that you already know. However, the

Exact line is only compatible with CM implants

with Index.

Contact one of our consultants and discover the

advantages of the new Morse Taper implants and

whole family of Exact prosthetic components.

Versatility of Index Implant

Apart from the single CM interface for all implant diameters, the CM implants now have one more family of prosthetic components, the EXACT LINE. This line features have at their tip a hex index that allows positioning the prosthesis over the implant (prosthetic indexing), making our Morse Tapers line even more flexible.

CM Index Implants

Conventional

components or Exact

Only Conventional

Components

CM Implant CM Index Implants CM Implant

Page 30: Products Catalog - Neodent 2011

30

3.5mm

4.3mm

5.0mm

Init

ial

Dri

ll

Alv

im D

rill

2.0

Alv

im D

rill

3.5

Alv

im D

rill

4.3

Alv

im D

rill

5.0

Drill sequence

Launch

Product Characteristics:

•Morse Taper interface;

•NeoPoros Surface;

•Implant with conical central nucleus;

•Cervical conicity to reduce the compressive tension;

•Double and progressive threads;

•Cutting chambers in counterclockwise direction;

•Apical thread with blade shape;

•The installation is performed with specific drivers to the index

of the implant, providing the implant capture directly on

packaging, offering more safety and speed;

•Suitable for bones type III and IV and pos-extracting

installation;

•Unique prosthetic interface for all implant diameters;

•Best prosthetic resolution with CM Implant 2mm infraosseous;

•Perforation rotation: 500-800 rpm;

•Insertion rotation: 30 rpm.

Page 31: Products Catalog - Neodent 2011

31

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm

Ø 3.5

Ø 4.3

Ø 5.0

109.692 109.682 109.693 109.683 109.684

109.689 109.688 109.627 109.628 109.629

109.690 109.685 109.691 109.686 109.687

CM Cover Screw

117.013 117.017

2 mm

•Use Digital Driver 1.2mm (104.007) for installation;

•Do not exceed torque of 10 N.cm.

•Use Digital Driver 1.2mm (104.007) for

installation;

•Do not exceed torque of 10 N.cm.

Healings

M o r s e T a p e r

Page 32: Products Catalog - Neodent 2011

32

3.5mm

3.75mm

4.0mm

Init

ial

Dri

ll

Tit

am

ax

Dri

ll 2

.0

Pil

ot

2/3

Tit

am

ax

Dri

ll 2

.8

Tit

am

ax

Dri

ll 3

.0

CM

Pil

ot

2.8

/3.5

Tit

am

ax

Dri

ll 3

.15

Tit

am

ax

Dri

ll 3

.3

5.0mm

CM

Pil

ot

3/3

.75

CM

Pil

ot

3.3

/4.0

Tit

am

ax

Dri

ll 3

.8

Tit

am

ax

Dri

ll 4

.3

CM

Pil

ot

4.3

/5.0

Drill sequence

Optional

•Cylindrical implant with Morse Taper interface;

•NeoPoros Surface;

•The installation is performed with specific drivers to the index

of the implant, providing the implant capture directly on

packaging, offering more safety and speed;

•Double thread (faster installation and less trauma);

•High cutting capacity;

•Suitable for bones type I and II and grafting areas in block;

•Cover screw not included;

•Unique prosthetic interface for all implant diameters;

•Cervical diameter equal to implant diameter;

•Observe the specific Pilot Drill (countersink function);

•Better prosthetic resolution with CM Implant inserted 2mm

infraosseous;

•Perforation rotation: 800-1200 rpm;

•Insertion rotation: 30 rpm.

Product Characteristics:

Page 33: Products Catalog - Neodent 2011

33

Ø 5.0

Ø 4.0

7.0 mm 8.0 mm 9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm

109.613 109.614 109.615 109.616 109.617 109.618 109.619

109.606

109.642

109.607

109.643

109.608

109.644

109.609

109.645

109.610

109.646

109.611 109.612

109.630 109.631 109.632 109.633 109.620 109.634 109.635

Ø 3.5

Ø 3.75

CM Cover Screw

117.013 117.017

2 mm

•Use Digital Driver 1.2mm (104.007) for

installation;

•Do not exceed torque of 10 N.cm.

•Use Digital Driver 1.2mm (104.007) for installation;

•Do not exceed torque of 10 N.cm.

Healings

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

M o r s e T a p e r

Page 34: Products Catalog - Neodent 2011

34

•Cylindrical implant with Morse Taper interface;

•NeoPoros Surface;

•The installation is performed with specific drivers to the index of

the implant, providing the implant capture directly on packaging,

offering more safety and speed;

•Double thread (faster installation and less trauma);

•High compaction capacity (bone expansion);

•Suitable for bones type III and IV and in areas with little bone

thickness;

•Cover screw not included;

•Unique prosthetic interface for all implant diameters;

•Cervical diameter equal to implant diameter;

•Simplified instrumentation in the prepare of surgical alveolus;

•Best prosthetic resolution with CM Implant 2mm infraosseous;

•Perforation rotation: 800-1200 rpm;

•Insertion rotation: 30 rpm.

Product Characteristics:

•Cylindrical implant with Morse Taper interface;

•NeoPoros Surface;

•The installation is performed with specific drivers to the index of

the implant, providing the implant capture directly on packaging,

offering more safety and speed;

•Double thread (faster installation and less trauma);

•High compaction capacity (bone expansion);

•Suitable for bones type III and IV and in areas with little bone

thickness;

•Cover screw not included;

•Unique prosthetic interface for all implant diameters;

•Cervical diameter equal to implant diameter;

•Simplified instrumentation in the prepare of surgical alveolus;

•Best prosthetic resolution with CM Implant 2mm infraosseous;

•Perforation rotation: 800-1200 rpm;

•Insertion rotation: 30 rpm.

Product Characteristics:

Optional

3.5mm

3.75mm

4.0mm

Init

ial

Dri

ll

Tit

am

ax

Dri

ll 2

.0

Pil

ot

2/3

Tit

am

ax

Dri

ll 2

.8

Tit

am

ax

Dri

ll 3

.0

Drill sequence

Morse Taper

Page 35: Products Catalog - Neodent 2011

35

Ø 4.0

9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm

Ø 3.5

Ø 3.75

109.661 109.662 109.663 109.664 109.665

109.666 109.667 109.668 109.669 109.670

109.636 109.637 109.638 109.639 109.640

M o r s e T a p e r

CM Cover Screw

117.013 117.017

2 mm

•Use Digital Driver 1.2mm (104.007) for

installation;

•Do not exceed torque of 10 N.cm.

Healings

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

•Use Digital Driver 1.2mm (104.007) for installation;

•Do not exceed torque of 10 N.cm.

Page 36: Products Catalog - Neodent 2011

36

3.5mm

4.3mm

5.0mm

Init

ial

Dri

ll

Alv

im D

rill

2.0

Alv

im D

rill

3.5

CM

Pil

ot

2.8

/3.5

Alv

im D

rill

4.3

CM

Pil

ot

3.6

/4.3

Alv

im D

rill

5.0

CM

Pil

ot

4.3

/5.0

Drill Sequence

Product Characteristics:

• Conical implant with Morse Taper interface;

• NeoPoros Surface;

• The installation is performed with specific drivers to the

index of the implant, providing the implant capture directly

on packaging, offering more safety and speed;

• Double thread (faster installation and less trauma);

• Suitable for bones type III and IV and pos-extracting

installation;

• Cover screw not included;

• Cervical diameter equal to implant diameter;

• Unique prosthetic interface for all implant diameters;

• Observe the specific Pilot Drill (function countersink);

• Best prosthetic resolution with CM Implant 2mm

infraosseous;

• Perforation rotation: 500-800 rpm;

• Insertion rotation: 30 rpm.

Page 37: Products Catalog - Neodent 2011

37

8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm

Ø 3.5

Ø 4.3

Ø 5.0

109.657 109.658 109.659 109.621 109.660

109.647 109.648 109.649 109.622 109.651

109.652 109.653 109.654 109.655 109.656

M o r s e T a p e r

CM Cover Screw

117.013 117.017

2 mm

•Use Digital Driver 1.2mm

(104.007) for installation;

•Do not exceed torque of 10 N.cm.

Healings

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

•Use Digital Driver 1.2mm (104.007) for installation;

•Do not exceed torque of 10 N.cm.

Page 38: Products Catalog - Neodent 2011

38

Obligatory for Cortical Implant and Optional for CM Medullar Implant

•Cylindrical implant with Morse Taper interface;

•NeoPoros Surface;

•Pre-mounted;

•Cover screw not included;

•Optimization of primary stability;

•Excellent alternative to posterior edentulous lower jaw;

•Specific Surgical Kit;

•Observe the specific Pilot Drill (same function of

countersink drill);

•In Medullar Titamax WS Implant, the pilot drill is optional;

•Perforation rotation: 200-300 rpm;

•Insertion rotation: 30 rpm;

•Unique Morse Taper prosthetic interface (same

dimensions as CM Zygomatic Implants).

Product Characteristics:

•Cylindrical implant with Morse Taper interface;

•NeoPoros Surface;

•Pre-mounted;

•Cover screw not included;

•Optimization of primary stability;

•Excellent alternative to posterior edentulous lower jaw;

•Specific Surgical Kit;

•Observe the specific Pilot Drill (same function of

Product Characteristics:

countersink drill);

•In Medullar Titamax WS Implant, the pilot drill is optional;

•Perforation rotation: 200-300 rpm;

•Insertion rotation: 30 rpm;

•Unique Morse Taper prosthetic interface (same

dimensions as CM Zygomatic Implants).

•Pre-mounted;

•Cover screw not included;

•Optimization of primary stability;

•Excellent alternative to posterior edentulous lower jaw;

•Specific Surgical Kit;

•Observe the specific Pilot Drill (same function of

4.0mm

5.0mm

6.0mm

Init

ial

Dri

ll

Tit

am

ax

Dri

ll 2

.0

Pil

ot

2/3

Tit

am

ax

Dri

ll 2

.8

Tit

am

ax

Dri

ll 3

.0

CM

Pil

ot

2.8

/3.5

Tit

am

ax

Dri

ll 3

.3

CM

Pil

ot

3/3

.75

CM

Pil

ot

3.3

/4.0

Tit

am

ax

Dri

ll 3

.8

Tit

am

ax

Dri

ll 4

.3

CM

Pil

ot

3.8

/4.3

Tit

am

ax

Dri

ll 5

.3

CM

Pil

ot

4.3

/5.0

CM

Pil

ot

4.3

/5.3

CM

Pil

ot

5.3

/6.0

Drill sequence

Morse Taper

Medullar and Cortical

Page 39: Products Catalog - Neodent 2011

39

Cortical Medullar

5.0 mm 6.0 mm

Ø 4.0

Ø 5.0

Ø 6.0

109.604

109.574

109.605

109.575

109.576 109.577

WS Cover Screw

117.016

3.5 mm2.5 mm1.5 mm0.8 mm

106.186 106.187 106.188 106.189

5.0 mm 6.0 mm

Ø 5.0

Ø 6.0

109.578 109.579

109.580 109.581

•Use Digital Driver 1.2mm (104.007)

for installation;

•Do not exceed torque of 10 N.cm.

WS Healings

M o r s e T a p e r

•Use Digital Driver 1.2mm (104.007) for installation;

•Do not exceed torque of 10 N.cm.

Page 40: Products Catalog - Neodent 2011

4040

Demonstrative sequence of

CM Abutment and WS Abutment

CM Abutment WS Abutment

Torque Connection 1.6

Prosthetic Torque Ratchet Driver

Transfer GT Open Tray

Transfer

Transfer GT Closed Tray

Transfer

GT Analogue

GT Protective Cylinder

GT Cylinder

Co

Cr

Tit

an

ium

Ca

sta

ble

Torque Connection 1.2

Prosthetic Torque Ratchet Driver

32N.cm

•Same prosthetic sequence as the GT Implant;

•Available in Titanium;

•Minimum interocclusal space of 5.0mm from the

mucosa level;

•Conicity 15°;

•Single screw-retained prosthesis (anti-rotational);

•The cylinders come with Neotorque screw, except

the castables, that comes with Titanium screw.

Page 41: Products Catalog - Neodent 2011

41

106.102

GT ProtectiveCylinder

108.039

OpenTray

ClosedTray

108.040

101.037

GT Analogue

GT CylinderScrew

Titanium Neotorque

116.038 116.228

Castable

Titanium

CoCr

GT Transfer GT Cylinder

118.180

118.179

118.242

• Observe corresponding sequence and indicated torque;

• Use Torque Connection 1.6mm (105.006);• To torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Available: Titanium: for provisional prosthesis; CoCr: overcastting; Castable: casting.•With screw;•To screw torque, use Torque Connection 1.2mm (105.005);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);

•Anti-rotational.

•Available in Titanium;•Replica of implant platform or prosthetic component;

•For prosthesis construction or prosthetic planning.

•Available in Titanium;•Used to protect the component during the prosthesis construction;

•To installation, use Digital Driver 1.2mm (104.007).

•Available in Titanium;•For transference and molding of prosthesis;

•For open tray or closed tray technique;

•Anti-rotational.

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

115.162 115.147 115.148 115.152 115.163 115.164

CM Abutment

0.8 mm 1.5 mm 2.5 mm 3.5 mm

WS Abutment

115.180 115.181 115.182 115.183

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

M o r s e T a p e r

Page 42: Products Catalog - Neodent 2011

42

WS MiniConical Abutment

CM MiniConical Abutment

CM Angled MiniConical Abutment

and EXACT(170 and 300)

ProstheticAbutment Driver

ProstheticAbutment Driver

TorqueConnection 0.9mm

Transfer Mini Conical Abutment

Transfer Mini Conical Abutment

Multifuncional

Analogue Mini Conical Abutment

Protective Cylinder of Mini Conical Abutment

Cylinder of Mini Conical Abutment

No

ble

/ C

oC

r

Tit

an

ium

Ca

sta

ble

Torque Connection 1.2

Prosthetic Torque Ratchet Driver

Prosthetic Torque Ratchet Driver

32N.cm

32N.cm

15N.cm

42

Demonstrative sequence

CM Mini Abutment and WSCM Angled Mini Abutment

•Available in Titanium;

•Minimum interocclusal space of 4.4mm from the

mucosa level;

•Multiple and screw-retained prosthesis;

•Conicality 20°;

•The cylinders come with Neotorque screw, except

the castables, that comes with Titanium screw.

Page 43: Products Catalog - Neodent 2011

43

115.154

115.176

115.149

115.177

115.166170

115.169300

115.150

115.178

115.167

115.170

115.151

115.179

115.168

115.171

115.153 115.160

Analogue of MiniConical Abutment

Castable Titanium Noble CoCr CoCrfor welding

116.036

116.227116.037

0.8 mm

0.8 mm

1.5 mm

1.5 mm

1.5 mm

2.5 mm

2.5 mm

2.5 mm

3.5 mm

3.5 mm

3.5 mm

4.5 mm 5.5 mm

CM Mini Conical Abutment

WS MiniConical Abutment

CM AngledMini Conical Abutment

•Observe sequence and indicated torque;•To component torque, use Prosthetic Abutment Driver (105.009);•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

• Height of CM angled prosthetic components available on page 54;• To component torque, use Torque Connection 0.9 (105.065).

CylinderMini Conical Abutment

•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting; Gold: gold alloy with high melting range.•With screw;•To screw torque, use Torque Connection 1.2mm (105.005)•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Rotational for screw-retained multiple elements.

118.112Ø 4.1

Ø 4.1

Ø 4.1

Ø 4.1

Ø 4.1

118.113 118.206 118.209 118.210

106.054

Protective Cylinder ofMini Conical Abutment

108.022 108.068

101.020

Transfer of MiniConical Abutment

OpenTray

Short Screw

Multifunctional

Cylinder Screw

Titanium Neotorque•Available in Titanium;•Replica of prosthetic component;•For prosthesis construction or prosthetic planning.

•Available in Titanium;•Used to protect the component during the prosthesis construction;•To installation, use Digital Driver 1.2mm (104.007).

•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Rotational.

108.021

ClosedTray

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

M o r s e T a p e r

Page 44: Products Catalog - Neodent 2011

44

Cylinder of Micro Abutment

Co

Cr

Ca

sta

ble

Tit

an

ium

CM Micro Abutment

Prosthetic Abutment Driver

Prosthetic Torque

Ratchet Driver

Transfer CM Micro Abutment Open tray

Analogue of Micro Abutment

Protective Cylinder of Micro Abutment

Torque Connection 1.2

Prosthetic TorqueRatchet Driver

32N.cm

44

Demonstrative sequence of

CM Micro Abutment

•Available in Titanium;

•Multiple and screw-retained prosthesis;

•Indicated to CM Implants with diameter of 3.5mm

and close to each other;

•Minimum interocclusal space of 4.4mm from the

mucosa level;

•Prosthetic fitting diameter of 3.3mm ;

•The cylinders come with Neotorque screw, except

the castables, that comes with Titanium screw.

3.5

Page 45: Products Catalog - Neodent 2011

45

Transfer ofCM Micro Abutment

118.246

Titanium

118.245 118.247

CoCr Castable

115.200 115.201 115.202

1.5 mm 2.5 mm 3.5 mm

CM MicroAbutment

•Observe sequence and indicated torque;•To component torque, use Prosthetic Abutment Driver (105.009);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Cylinder of CM Micro Abutment

•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting.•With screw;•To screw torque, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Rotational for screw-retained multiple elements.

116.227116.037

106.199

Protective Cylinder ofCM Micro Abutment

CylinderScrew

Titanium Neotorque

•Available in Titanium;•Used to protect the component during the prosthesis construction;

•To installation, use Digital Driver 1.2mm (104.007).

Analogue ofCM Micro Abutment

108.070

101.057

Rotational

•Available in Titanium;•Replica of prosthetic component;

•For prosthesis construction or prosthetic planning.

•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray technique;•Rotational.

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

M o r s e T a p e r

Page 46: Products Catalog - Neodent 2011

46

Transfer of CM Exact Implant Closed tray

Transfer of CM Exact Implant Closed tray

Transfer of CM Exact Implant Open

tray

CM Implant Analogue

Torque Connection 0.9mm

Prosthetic TorqueRatchet Driver

Optional sequenceIndicated sequence

CM Anatomic Post

Customization if is necessary

Conventional molding

Laboratorial Phase

Laboratorial Phase

Prosthesis conclusion

Torque Connection 0,9mm

Prosthetic TorqueRatchet Driver

CM Anatomic Post

15N.cm

15N.cm

46

Demonstrative sequence of

CM and Exact Anatomic Post

•Available in Titanium;

•Cemented unitary prosthesis;

•Possible customization;

•Indicated for aesthetic area;

•Height of anatomic prosthetic

components available on page 55.

maximum

Page 47: Products Catalog - Neodent 2011

47

1.5 mm

1.5 mm

2.5 mm

2.5 mm

3.5 mm

3.5 mm

Lateral CMAnatomic Post

Lateral ExactCM Anatomic Post

114.419 114.420 114.421

CM Implant Transfer

•Available in Titanium;•Component with molding function for the prosthesis confection;

•For open tray and closed tray technique;•Length: - Short: 15 mm; - Conventional: 20 mm.

CM ImplantAnalogue

101.058

•Available in Titanium;•Replica of the implant;•To the prosthesis confection or prosthetic planning.

1.5 mm

1.5 mm

2.5 mm

2.5 mm

3.5 mm

3.5 mm

CM AnatomicPost

Exact CMAnatomic Post

•Available in Titanium;•Cemented prosthesis;•To installation, use Torque Connection 0,9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Available in Titanium;•Cemented prosthesis;•To installation, use Torque Connection 0,9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Exact component exclusive for CM Index implants.

114.328

114.422 114.425

114.329

114.423 114.426

114.330

114.424 114.427

108.069

Short

Exact

Conventional

Opentray

108.065

108.041

108.076

Closed tray

M o r s e T a p e r

Page 48: Products Catalog - Neodent 2011

48

Prosthetic Torque

Ratchet Driver

Transfer of CM Post

Analogue of

CM Post

Cylinder of Universal Post

Ø 3.3

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Alu

min

a

Alu

min

a

Pro

vis

ion

al

Pro

vis

ion

al

Ca

sta

ble

Ca

sta

ble

32N.cm

CM Universal Post

Torque Connection 1.2 mm

48

Demonstrative sequence of

CM Universal Post

•Available in Titanium;

•Cemented single prosthesis;

•Straight component with single body.

Page 49: Products Catalog - Neodent 2011

49

114.129 114.077 114.078 114.079 114.136 114.137

114.130 114.086 114.087 114.088 114.139 114.140

114.131 114.080 114.081 114.082 114.142 114.143

114.132 114.083 114.084 114.085 114.145 114.146

UniversalPost Transfer

UniversalPost Set

UniversalPost Analogue

118.186

108.042

108.060101.038

118.181 118.192

118.188

108.044

108.062101.040

118.183 118.194

118.187

108.043

108.061101.039

118.182 118.193

118.189

108.045

108.063101.041

118.184 118.195

ProvisionalAlumina Castable

UniversalPost Cylinder

0.8 mm

Ø 3.3

Ø 3.3

Ø 3.3

Ø 3.3 Ø 3.3

Ø 3.3

Ø 3.3

Ø 3.3 Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5Ø 4.5

Ø 4.5

4 m

m

4 m

m

4 m

m4

mm

4 m

m6

mm

6 m

m6

mm

6 m

m

6 m

m

1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

CM Universal Post

•To installation, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

• Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.• Compatible with all Universal Posts, if not prepared.

•Available in polymer;•Component with molding function by prosthesis construction;

•For closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;

•Anti-rotational.

• Available in Titanium;• Replica of prosthetic component platform;

• For prosthesis construction and prosthetic planning.

•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.

M o r s e T a p e r

Page 50: Products Catalog - Neodent 2011

50

WS ImplantTransfer

Closed tray

CM Implant

Analogue

WS Implant

Analogue

Torque Connection 0.9mm

Torque Connection 1.2mm

Prosthetic Torque

Ratchet Driver

WS Post

Laboratorial PhaseLaboratorial Phase

CM ImplantTransfer

Closed tray

CM ImplantTransfer

Open tray

Transfer of ExactCM ImplantClosed tray

32N.cm

15N.cm

CM UniversalPost Through

Screw

Exact CMUniversal Post

50

Demonstrative sequence of

CM Universal Post Through Screw Exact CM Universal PostWS Universal Post

•Available in Titanium;

•Cemented single prosthesis;

•Indicated for laboratorial customization.

Prosthesis concludedProsthesis concluded

maximum

Page 51: Products Catalog - Neodent 2011

51

WS Universal Post

114.183 114.184 114.185 114.186

114.187 114.188 114.189 114.190

0.8 mm

Ø 4.5 4 m

m6

mm

1.5 mm 2.5 mm 3.5 mm

•In two pieces (body and screw);•To installation, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

101.058 101.055

CM WS

Analogue

•Available in Titanium;•Replica of prosthetic component platform;

•For prosthesis construction and prosthetic planning.

114.148 114.149 114.150 114.151 114.152 114.153

114.155 114.156 114.157 114.158 114.159 114.160

114.115 114.117 114.118 114.119 114.162 114.163

114.116 114.120 114.121 114.122 114.165 114.166

CM UniversalPost Through Screw

0.8 mm

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

•To installation, use Torque Connection 0.9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

114.408 114.360 114.361 114.362 114.363 114.364

114.409 114.366 114.367 114.368 114.369 114.370

114.410 114.357 114.358 114.359 114.372 114.373

114.411 114.340 114.341 114.342 114.375 114.376

Exact CMUniversal Post

0.8 mm

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

•Component with through screw;•To installation, use Torque Connection 0.9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Component Exact exclusive for CM Implant Index.

M o r s e T a p e r

CM Implant Transfer

•Available in Titanium;•Component with molding function for the prosthesis confection;

•For open tray and closed tray technique;•Length: - Short: 15 mm; - Conventional: 20 mm

108.069

Short

Exact

WS

Conventional

Opentray

108.065

108.041

108.076

108.064

Closed tray

Page 52: Products Catalog - Neodent 2011

52

Prosthetic Torque

Ratchet Driver

CM AngledUniversal Post

Exact CMAngled Universal

Post

Torque

Connection 0.9mm

15N.cm

CM Post Transfer

CM Post

Analogue

Universal Post

Cylinder

Ø 3.3

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Alu

min

a

Alu

min

a

Pro

vis

ion

al

Pro

vis

ion

al

Ca

sta

ble

Ca

sta

ble

52

Demonstrative sequence of

Universal PostAngled CM and Exact

•Available in Titanium;

•Cemented single prosthesis.

Page 53: Products Catalog - Neodent 2011

53

Ø 3.3

Ø 3.3

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5

4 m

m4

mm

6 m

m6

mm

1.5 mm 2.5 mm 3.5 mm

Exact CMAngled Universal Post

114.390

114.396

114.402 114.403 114.404

114.405 114.406 114.407

114.397 114.398

114.399 114.400 114.401

114.391 114.392

114.393 114.394 114.395

114.384 114.385 114.386

114.387 114.388 114.389

170 170

300 300

•Component with through screw;•To installation, use Torque Connection 0.9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Height of CM angled prosthetic components available on page 54;•Exact component exclusive for CM Index implant.

Universal PostTransfer

UniversalPost Set

UniversalPost Analogue

108.042

108.060101.038

108.044

108.062101.040

108.043

108.061101.039

108.045

108.063101.041

Ø 3.3

Ø 3.3 Ø 3.3

Ø 3.3

Ø 3.3Ø 3.3

Ø 4.5

Ø 4.5Ø 4.5

Ø 4.5

Ø 4.5Ø 4.5

4 m

m4

mm

4 m

m

6 m

m6

mm

6 m

m

•Available in polymer;•Component with molding fuction to the prosthesis confection;

•For closed tray technique;•Select Transfer according to the component to be molded as prosthetic planning;

•Anti-rotational.

•Available in Titanium;•Replica of prosthetic component platform;

•For prosthesis construction and prosthetic planning.

•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.

Ø 3.3

Ø 3.3

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5

4 m

m4

mm

6 m

m6

mm

1.5 mm 2.5 mm 3.5 mm

CM AngledUniversal Post

114.095

114.101

114.107 114.108 114.109

114.110 114.111 114.112

114.102 114.103

114.104 114.105 114.106

114.096 114.097

114.098 114.099 114.100

114.089 114.090 114.091

114.092 114.093 114.094

M o r s e T a p e r

118.186 118.181 118.192

118.188 118.183 118.194

118.187 118.182 118.193

118.189 118.184 118.195

ProvisionalAlumina Castable

UniversalPost Cylinder

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

•Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.•Compatible with all Universal Posts, if not prepared.

Page 54: Products Catalog - Neodent 2011

54

Angled Universal Post

Ø 4.5Ø 3.3

Angled Mini Conical Abutment

300

170

300170

5.8

0

4.5

05

.20

4.9

0

4.8

0

3.5

04

.20

3.9

0

3.8

0

2.5

03

.20

2.9

0

3.5

0

3.5

03

.50

3.5

0

4.9

0

3.5

0

5.9

0

3.5

0

2.5

0

2.5

02

.50

2.5

0

3.9

0

2.5

0 4.9

0

2.5

0

1.5

0

1.5

01.

50

1.5

0

2.9

0

1.5

0 3.9

0

1.5

0

54

Height of CM AngledProsthetic Components

Page 55: Products Catalog - Neodent 2011

55

CM Anatomic Post

CM Lateral Anatomic Post

8 m

m6 m

mT

ran

smu

co

sal

Tra

nsm

uc

osa

l

5 mm6 mm

6.5

mm

5.3

mm

Tra

nsm

uc

osa

l

Tra

nsm

uc

osa

l

4.3 mm4.7 mm

55

Height of Anatomic Post andLateral Anatomic Post

Page 56: Products Catalog - Neodent 2011

56

CM Mini Ball

Attachment

Prosthetic Abutment Driver

Prosthetic Torque Ratchet Driver

Straight

positioner

Positioner

70

Positioner

140

O’ring with Cylinder

Disk

32N.cm

Protection Disk Positioner

56

Demonstrative sequence of

CM Mini Ball Attachment

•Available in Titanium;

•Application of Nitride Titanium coating for increased the

wear resistance;

•Directly over the implant;

•For Overdenture prosthesis, its function is the O’ring

retention;

•It’s recommended capture the components in patient’s

mouth, one by one;

•Obligatory to use positioner for capture;

•O’ring with protection disc;

•See the demonstrative sequence of Mini Ball Attachment

on page 126.

Page 57: Products Catalog - Neodent 2011

57

M o r s e T a p e r

CastableBall Attachment

102.069 102.070 102.071 102.097

CM Mini BallAttachment

1.5 mm 2.5 mm 3.5 mm 4.5 mm

•Select according to the mucosa height;•To installation, use Prosthetic Abutment Driver (105.009);•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.

102.078

straight, 70 and 140

Positioners

•Available in polymer;•Indicated to define the correct distance between Attachment Ball components and O’ring with cylinder;•Corrects the parallelism between the implants;•Essential for O’ring capturing.

102.076

102.073

102.077

O’ring with Cylinder

Mini O’ring

Protection Disk

102.075

O’ringRemover

O’ringMount

104.044

104.043

•Digital Driver with function of O’ring replacing to the cylinder.

•Digital Driver with function of O’ring replacing to the cylinder.

•Available in Titanium (cylinder);•Available in polymer (O’ring);•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;

•Protection disk included;•Not autoclavable.

•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;

•Not Autoclavable.

•Package with 10 units.

Page 58: Products Catalog - Neodent 2011

58

• Ensures the integrity of external hexagon;

• Maintains original rotational freedom;

• More practicality and safety;

• Increased mechanical strength to the insertion;

• Transport tweezers to the safety in handling the implant.

The solution to the limitations of conventional external hexagon.

Area of Internal torque. Tweezers that ensures increased safety in the

implant transport.

Page 59: Products Catalog - Neodent 2011

59

Hex 2

.37 m

m

Ø4.1 mm

Ø3.3 mm

1 mm

0.7 mm

Hex 3.3 mm

Ø 5.0 mm

Hex 2.7 mm

Hex 2.7 mm

Ø 3.3

Ø 4.1

Ø 4.3

Ø 5.0

•Castable UCLA •CoCr UCLA

•SF Mini Conical Abutment (multiple)

•Angled Mini Conical Abutment 17°and 30° (multiple)

•SF Conical Abutment (single)

•Castable UCLA •Noble UCLA •CoCr UCLA

•Mini Conical Abutment (multiple)

•Angled Mini Conical Abutment 17°and 30° (multiple)

•Conical Abutment (single)

•Castable UCLA •CoCr UCLA

•SF Mini Conical Abutment (multiple)

•Angled Mini Conical Abutment 17° and 30° (multiple)

•SF Conical Abutment (1 piece)

•Castable UCLA •CoCr UCLA

•Angled Post 17° •Universal Post •Castable UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

•Angled Post 17° and 30° •Universal Post •Customizable Post •Castable UCLA •Noble UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment •Mini Conical Abutment •Angled Mini Conical

Abutment 17°and 30° •Cylinder and Distal

External Bar

Passive Fitting Technique•Castable Cylinder of Mini

Abutment •Titanium Cylinder of Mini

Abutment •Brass Cylinder of Mini

Abutment

•Mini Conical Abutment •Angled Mini Conical

Abutment 17°and 30° •Cylinder and Distal

External Bar

Passive Fitting Technique•Castable Cylinder of Mini

Abutment •Titanium Cylinder of Mini

Abutment •Brass Cylinder of Mini

Abutment

•Mini Conical Abutment •Angled Mini Conical

Abutment 17°and 30° •Cylinder and Distal

External Bar

Passive Fitting Technique•Castable Cylinder of Mini

Abutment •Titanium Cylinder of Mini

Abutment •Brass Cylinder of Mini

Abutment

•Angled Post 17° •Castable UCLA •Titanium UCLA •CoCr UCLA

3.3 and 3.5 mm

3.75 and 4.0 mm

4.3 mm

4.5 and 5.0 mm

EXTERNAL HEX

Inte

rna

l Thre

ad

Ø 1

.8In

tern

al T

hre

ad

Ø 2

.0In

tern

al T

hre

ad

Ø 2

.0In

tern

al T

hre

ad

Ø 2

.5

•Angled Post 17° •Customizable Post •Castable UCLA •Titanium UCLA •CoCr UCLA

•Mini Ball Attachment

1 mm

1 mm

Ø 4.3 mm

E x t e r n a lH e x

COMPONENTS INDICATION TABLE

Screw-retained Prosthesis

Cemented Prosthesis

Overdenture Protocol

Page 60: Products Catalog - Neodent 2011

60

•Cylindrical implant with External Hex interface;

•NeoPoros Surface;

•Capture and installation with contra-angle or manual

without mount use (reduction of surgical time);

•Installation by the internal hexagon of the implant,

increasing the mechanical strength when high torques are

applied, preserving the integrity of the external hexagon;

•Double thread (faster installation and less trauma);

•High cutting capacity;

•Suitable for bones type I and II and grafting areas in block

•Cover screw and mount not included;

•Prosthetic platform: 4.1mm and 5.0mm;

•Perforation rotation: 800-1200 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

•Cylindrical implant with External Hex interface;

•NeoPoros Surface;

•Capture and installation with contra-angle or manual

without mount use (reduction of surgical time);

•Installation by the internal hexagon of the implant,

increasing the mechanical strength when high torques are

applied, preserving the integrity of the external hexagon;

•Double thread (faster installation and less trauma);

•High cutting capacity;

•Suitable for bones type I and II and grafting areas in block

•Cover screw and mount not included;

•Prosthetic platform: 4.1mm and 5.0mm;

•Perforation rotation: 800-1200 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

3.75 mm

4.0 mm

4.5 mm

5.0 mm

Init

ial

Dri

ll

Tit

am

ax

Dri

ll 2

.0

Pil

ot

2/3

Tit

am

ax

Dri

ll 3

.0

Tit

am

ax

Dri

ll 3

.3

Tit

am

ax

Dri

ll 3

.15

Pil

ot

3/3

.75

Co

un

ters

ink

4.1

SF

Tit

am

ax

Dri

ll 3

.8

Tit

am

ax

Dri

ll 4

.3

Co

un

ters

ink

5.0

SF

Optional

Drill sequence

Page 61: Products Catalog - Neodent 2011

61

9.0 mm7.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm

Ø 4.0

Ø 3.75

Platform(4.1)

Platform(4.1)

Platform(5.0)

Platform(5.0)

Ø 4.5

Ø 5.0

109.284 109.285 109.286 109.287 109.288

109.302 109.303 109.304 109.305 109.306

109.327 109.328 109.329

109.294 109.295 109.296 109.297

Cover Screw

117.018 117.003

4.1 mm 5.0 mm

•Use Digital Driver 0.9mm (104.039) to the

installation of Cover Screw platform 4.1 and Digital

Driver 1.2mm (104.007) to the installation of Cover

Screw platform 5.0;

•Do not exceed torque of 10 N.cm.

106.092

106.127 106.128 106.129

106.093 106.094

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Ø 5.0

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Ø 5.0

Slim Fit Healings

106.195 106.196 106.197

106.190 106.191 106.192

E x t e r n a lH e x

Page 62: Products Catalog - Neodent 2011

62

•Cylindrical implant with External Hex interface;

•NeoPoros Surface;

•Capture and installation with contra-angle or manual without

mount

use (reduction of surgical time);

•Installation through implant internal hex, increasing the

mechanical resistance (when applied elevated torque),

preserving the external hex integrity;

•Double thread (faster installation and less trauma);

•High compaction capacity (bone expansion);

•Suitable for bones type III and IV;

•Cover screw not included;

•Simplified instrumentation in the prepare of surgical alveolus;

•Prosthetic platform 4.1mm;

•Perforation rotation: 800-1200 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

•Cylindrical implant with External Hex interface;

•NeoPoros Surface;

•Capture and installation with contra-angle or manual without

mount

use (reduction of surgical time);

•Installation through implant internal hex, increasing the

mechanical resistance (when applied elevated torque),

preserving the external hex integrity;

•Double thread (faster installation and less trauma);

•High compaction capacity (bone expansion);

•Suitable for bones type III and IV;

•Cover screw not included;

•Simplified instrumentation in the prepare of surgical alveolus;

•Prosthetic platform 4.1mm;

•Perforation rotation: 800-1200 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

3.75 mm

4.0 mm

Init

ial

Dri

ll

Tit

am

ax

Dri

ll 2

.0

Pil

ot

2/3

Tit

am

ax

Dri

ll 2

.8

Tit

am

ax

Dri

ll 3

.0

Optional

Drill sequence

Internal Torque

Page 63: Products Catalog - Neodent 2011

63

9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm

Ø 4.0

Ø 3.75

109.588

109.582

109.589

109.583

109.590

109.584

109.591

109.585

109.592

109.586Platform

(4.1)

Platform(4.1)

Cover Screw

117.0184.1 mm

•Use Digital Driver 0.9mm (104.039) to the

installation of Cover Screw platform 4.1;

•Do not exceed torque of 10 N.cm.

106.092 106.093 106.094

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Slim Fit Healings

106.190 106.191 106.192

E x t e r n a lH e x

Page 64: Products Catalog - Neodent 2011

64

•Conical implant with External Hex interface;

•NeoPoros Surface;

•Capture and installation with contra-angle or manual

without mount use (reduction of surgical time);

•Installation through implant internal hex, increasing the

mechanical resistance (when applied elevated torque),

preserving the external hex integrity;

•Suitable for bones type III and IV and pos-extracting

installation;

•Cover screw and mount not included;

•External Hex with height of 1mm: platform 4.3 and 5.0;

•Perforation rotation: 500-800 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

•Conical implant with External Hex interface;

•NeoPoros Surface;

•Capture and installation with contra-angle or manual

without mount use (reduction of surgical time);

•Installation through implant internal hex, increasing the

mechanical resistance (when applied elevated torque),

preserving the external hex integrity;

•Suitable for bones type III and IV and pos-extracting

installation;

•Cover screw and mount not included;

•External Hex with height of 1mm: platform 4.3 and 5.0;

•Perforation rotation: 500-800 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

4.3 mm

5.0 mm

Init

ial

Dri

ll

Alv

im D

rill

2.0

Alv

im D

rill

3.5

Alv

im D

rill

4.3

Alv

im D

rill

5.0

Co

un

ters

ink

4.3

Co

un

ters

ink

5.0

SF

Optional

Drill sequence

Page 65: Products Catalog - Neodent 2011

65

Ø 5.0

Ø 4.3

10.0 mm 13.0 mm 16.0 mm

109.321 109.322 109.323

109.324 109.325 109.326

Cover Screw

117.006 117.003

4.3 mm 5.0 mm

•Use Digital Driver 0.9mm (104.039) to the installation

of Cover Screw platform 4.3 and Digital Driver 1.2mm

(104.007) to the installation of Cover Screw platform 5.0;

•Do not exceed torque of 10 N.cm.

106.140

106.127 106.128 106.129

106.141 106.142

2.0 mm 3.0 mm 4.0 mm

Ø 4.3

Ø 5.0

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 4.3

Parallel Healings

106.132 106.133 106.134

2.0 mm 3.0 mm 4.0 mm

Ø 5.0

Slim Fit Healings

106.195 106.196 106.197

E x t e r n a lH e x

Page 66: Products Catalog - Neodent 2011

66

•Cylindrical implant with External Hex;

•NeoPoros Surface;

•Cover screw not included;

•Double thread (faster installation and less trauma);

•High cutting capacity;

•Suitable for bones type I and II in reduced prosthetic

spaces (upper lateral incisor and lower incisor);

•Prosthetic platform 3.3mm;

•External Hex with height of 1mm;

•Resistance to the installation torque: 45 N.cm;

•Perforation rotation: 800-1200 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:In

itia

l D

rill

Tit

am

ax

Dri

ll 2

.0

Tit

am

ax

Dri

ll 2

.8

Co

un

ters

ink

3.3

Drill Sequence

Cortical with Mount

Page 67: Products Catalog - Neodent 2011

67

11.0 mm9.0 mm 13.0 mm 15.0 mm 17.0 mm

Ø 3.3

109.140 109.141 109.142 109.143 109.144

Cover Screw

117.0013.3 mm

•Use Digital Driver 0.9mm (104.039) to the installation

of Cover Screw platform 4.3;

•Do not exceed torque of 10 N.cm.

106.065 106.066 106.067

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Parallel Healings

106.060 106.061 106.062

Page 68: Products Catalog - Neodent 2011

68

•Conical implant with External Hex;

•NeoPoros Surface;

•Cover screw not included;

•Suitable for bones type III and IV in reduced

prosthetic spaces (upper lateral incisor and lower

incisor) and pos-extracting installation;

•Prosthetic platform 3.3mm;

•External Hex with height of 1mm;

•Resistance to the installation torque: 45 N.cm;

•Perforation rotation: 500-800 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

Optional

Init

ial

Dri

ll

Alv

im D

rill

2.0

Alv

im D

rill

3.5

Co

un

ters

ink

3.3

Drill sequence

with Mount

Page 69: Products Catalog - Neodent 2011

69

Ø 3.5

10.0 mm 13.0 mm 16.0 mm

109.217 109.218 109.219

Platform(3.3)

Cover Screw

117.0013.3 mm

•Use Digital Driver 0.9mm (104.039) for the installation

of Cover Screw platform 3.3;

•Do not exceed torque of 10 N.cm.

106.065 106.066 106.067

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Parallel Healings

106.060 106.061 106.062

Page 70: Products Catalog - Neodent 2011

70

External Hex

The Slim Fit Line is the Neodent’s innovation for External Hex components, due to its parallel emergent profile which minimizes the bone renoval.

Get to know the benefits of the SLIM FIT line, and see how

certain details can make all the difference:

- Facilitates the fitting of the prosthetic component

by reducing the interference with the cortical bone;

- Preserves the cortical bone plates;

- Optimizes installation;

- Eases the procedures for soft tissue synthesis

(stitching) by increasing the abutment’s conicity.

Reduced Osteotomy

CONVENTIONAL ABUTMENT WITH SF OSTEOTOMY

SF ABUTMENT WITHCONVENTIONAL OSTEOTOMY

Page 71: Products Catalog - Neodent 2011

71

The SLIM FIT intermediaries provide an excellent

accommodation of peri-implant soft tissue, easing the

prosthetic procedures in surgical cases with immediate

loading and tissue stabilization at long term.

Less Aggressive Drills

For the SLIM FIT line, it is necessary to use the new

Countersink SF Drill, which has a new shape that reduces

the drilling diameter, reducing trauma and preserving the

bone tissue.

Soft Tissue Accommodation

Countersink SF Drill, which has a new shape that reduces

the drilling diameter, reducing trauma and preserving the

bone tissue.

Emergent Profile Slim Fit

Emergent Profile Conventional

CONVENTIONAL OSTEOTOMY

COUNTERSINK CONVENTIONAL NEW DRILL COUNTERSINK SLIM FIT

SLIM FIT OSTEOTOMY(LESS BONE REMOVAL)

Page 72: Products Catalog - Neodent 2011

7272

Demonstrative sequence of

External Hex

Conical Abutment

•Available in Titanium;

•Minimum interocclusal space of 6.1mm on platform 4.1,

and 6.7mm on platform 5.0mm, from the mucosa level;

•Conicality 15°;

•Single screw-retained prosthesis (anti-rotational);

•Cylinders with screw;

•Slim Fit components, that minimize bone remotion of

the Countersink Drill, facilitating the intermediate seating

and the tissue accommodation.

Torque Connection 1.2

SF ConicalAbutment 4.1mm

ConicalAbutment 4.3mm

ConicalAbutment 5.0mm

ProstheticAbutment Driver

TorqueConnection 1.6mm

Prosthetic Torque Ratchet Driver

Sequence 4.1 / 4.3 mm

Sequence5.0 mm

Conical AbutmentTransfer 5.0Open Tray

Conical AbutmentTransfer 4.1Open Tray

Conical AbutmentTransfer 5.0Closed Tray

Conical AbutmentTransfer 4.1Closed Tray

Conical AbutmentAnalogue 4.1

Conical AbutmentAnalogue 5.0

Protective Cylinder ofConical Abutment 4.1

Protective Cylinder ofConical Abutment 5.0

Prosthetic Torque Ratchet Driver

Conical Abutment Cylinder 4.1 Conical Abutment Cylinder 5.0

Ca

sta

ble

Tit

an

ium

Co

Cr

Ca

sta

ble

Tit

an

ium

Co

Cr

20N.cm

Page 73: Products Catalog - Neodent 2011

73

Ø 4.1

Ø 5.0

ConicalAbutment Analogue

Ø 4.1

Ø 5.0

Protective Cylinder ofConical Abutment

ConicalAbutment Transfer

Ø 4.1

Ø 5.0

Ø 4.1

Ø 5.0

Cylinder Screw ofConical Abutment

Titanium Neotorque

•Available in Titanium;•Component with molding function by prosthesis construction;

•For open tray or closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;

•Anti-rotational.

•Available in Titanium;•Used to protect the component during the prosthesis construction;

•To installation, use Digital Driver 1.2mm (104.007);

•Observe the compatible diameter with the prosthetic component.

•Available in Titanium;•Replica of implant platform or prosthetic component;

•For prosthesis construction or prosthetic planning;

•Observe compatible diameter with the prosthetic component.

Castable Titanium CoCr

ConicalAbutment Cylinder

Ø 4.1

Ø 5.0

•Observe corresponding sequence to the component diameter and indicated torque;

•For torque, use Prosthetic Abutment Driver (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Available in: Titanium: provisional prosthesis; CoCr: overcasting; Castable: casting.•Observe the corresponding sequence to the component diameter;

•Screw included;•To screw torque, use Torque Conection 1.2mm (105.005);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);

•Anti-rotational.

1 mm 2 mm

Ø 4.1

Ø 5.0

Ø 4.3

3 mm

Conical Abutment

Sli

m F

it

115.051 115.052 115.053

115.007 115.008 115.009

115.192 115.193 115.194

101.030

101.027

106.051

106.052

118.106 118.107 118.233

118.253118.110 118.111

108.035

108.025 108.104

Open Tray

108.075

Closed Tray

116.004 116.231

116.005 116.232

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Page 74: Products Catalog - Neodent 2011

74

Torque Connection 1.2

Torque Connection

1.2 mm

Prosthetic Torque Ratchet Driver

Sequence 3.3 / 4.1 / 4.3 mm

Sequence 5.0 mm

Mini Conical Abutment Analogue 4.1 Mini Conical Abutment Analogue 5.0

Protective Cylinder ofMini Conical Abutment 4.1

Protective Cylinder ofMini Conical Abutment 5.0

Prosthetic Torque Ratchet Driver

Open TrayTransfer Mini

Conical Abutment 4.1

Open TrayTransfer Mini

Conical Abutment 5.0

Closed TrayTransfer Mini

Conical Abutment 5.0

Angled Mini

Abutment 170 and 300

20N.cm

20N.cm

Cylinder of Mini Conical Abutment 4.1 Cylinder of Mini Conical Abutment 5.0

Ca

sta

ble

Tit

an

ium

Co

Cr

Ca

sta

ble

Tit

an

ium

No

ble

/ C

oC

r

Prosthetic

Abutment Driver

Prosthetic

Abutment Driver

Mini Conical Abutment

3.3 mm / 4.3 mm

SF Mini Conical

Abutment 4.1mm

32N.cm

Torque Connection

1.6mm

SF Mini Conical

Abutment 5.0 mm

32N.cm

Closed TrayTransfer Mini

Conical Abutment 4.1

74

Demonstrative sequence of

Mini Conical AbutmentAngled Mini Conical Abutment

•Available in Titanium;

•Minimum interocclusal space of 4.4mm on platform 4.1,

and 4.8mm on platform 5.0mm, from the mucosa level;

•Screw-retained and multiple prosthesis (rotational);

•Conicality 20°;

•Mini Angled Abutment presents 12 positions of fitting;

•The cylinders come with Neotorque screw, except the

castables, that comes with Titanium screw;

•Slim Fit components improve tissue accommodation,

installed after using Countersink Drill, which minimizes

bone removal.

External Hex

Page 75: Products Catalog - Neodent 2011

75

108.024

108.022 108.068

Mini ConicalAbutment Transfer

Short Screw

Opentray Multifunctional

Ø 4.1

Ø 5.0

•Available in Titanium;•Component with molding function to the prosthesis confection;

•For Open Tray or Closed Tray technique;•Select the transfer in accordance with the component to be moulded conforming to the planned prosthetics;

•Rotational.

2 mm

Ø 4.1

Ø 3.3

Ø 5.0

Ø 4.3

3 mm 4 mm

Angled MiniConical Abutment

115.084

115.137

115.074

115.138

115.075

115.139

115.076 115.077 115.078

115.094 115.095 115.096

170

•Minimum interocclusal space of 5.0mm for 17º and 5.5mm for 30º;

•Screw-retained and multiple prosthesis (rotational);

•Observe corresponding sequence to the component diameter;

•For torque, use Torque Connection 1.2 (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

118.112 118.113

118.114 118.115 118.240

Castable Titanium

118.206 118.209 118.210

Noble CoCrCoCr

for welding

Mini ConicalAbutment Cylinder

Ø 4.1

Ø 5.0

1 mm 2 mm

115.187 115.188

115.054

115.134

115.055

115.135

115.056

115.136

115.057

115.197 115.198 115.199

Ø 4.1

Ø 5.0

Ø 4.3

Ø 3.3

3 mm 4 mm

115.189 115.190

Mini Conical Abutment

Sli

m F

itS

lim

Fit

•Observe corresponding sequence to the component diameter;•For torque, use Prosthetic Abutment Driver (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Ø 4.1

Ø 5.0

106.054

106.055

Protective Cylinder ofMini Conical Abutment

•Available in Titanium;•Used to protect the component during the prosthesis construction;

•To installation, use Digital Driver 1.2mm (104.007);

•Observe the compatible diameter with the prosthetic component.

Ø 4.1

Ø 5.0 101.022

101.020

Mini ConicalAbutment Analogue

•Available in Titanium;•Replica of prosthetic component;•For prosthesis confection or prosthetic planning.

Ø 4.1

Ø 5.0

Cylinder Screw ofMini Conical Abutment

Titanium Neotorque

116.037 116.227

116.038 116.228

Ø 4.1

Ø 5.0

Ø 4.3 115.111 115.112

115.143 115.144

115.140 115.141

300

108.023

108.021

Closed tray

116.036

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

•Available in: Titanium: provisional prosthesis; CoCr: overcasting; Castable: casting; Noble: gold alloy with high melting range.•Screw included;•Observe the corresponding sequence to the component diameter;•To screw torque, use Torque Conection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Rotational for screw-retained multiple elements.

Page 76: Products Catalog - Neodent 2011

76

4.5

4.1

Transm

uco

us

4 ou 6

Universal Post Transfer

SF Universal Post

Neotorque Screw

Torque Connection 1.2

Universal Post Analogue

Universal Post Cylinder

Alumina

Universal Post Cylinder

Provisional

Universal Post Cylinder

Castable

Ø4.5 Ø4.5 Ø4.5

Ø4.5

Ø4.5

32N.cm

76

Demonstrative sequence of

SF Universal Post

•Available in Titanium;

•Cemented prosthesis;

•The Universal Post can be prepared according to

circunstances, and, in this case, the prosthetic sequence

can not be used;

•Compatible with platform 4.1 and 4.3 External Hex;

•Screw not included, for single elements select Neotorque

Screw;

•Available in two heights of cemented area: 4 or 6mm.

External Hex

Prosthetic TorqueRatchet Driver

Page 77: Products Catalog - Neodent 2011

77

•Available in polymer;•Component with molding function to prosthesis confection;

•For closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;

•Anti-rotational.

1 mm

4 m

m

4 m

m

4 m

m

4 m

m

2 mm

6 m

m

6 m

m

6 m

m

6 m

m

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5

3 mm

SF UniversalPost

UniversalPost Analogue

UniversalPost Set

•Available in Titanium;•Replica of prosthetic component;•For prosthesis confection or prosthetic planning.

•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.

108.045

108.044

UniversalPost Transfer

101.041

101.040

108.062

108.063

4 m

m6

mm

Ø 4.5

118.188 118.183 118.194

118.189 118.184 118.195

ProvisionalAlumina Castable

UniversalPost Cylinder

Ø 4.1

Ø 4.3

Neotorque Titanium

Hex Screw

116.180

114.428

114.431

114.429

114.432

114.430

114.433

116.002

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

• Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.• Compatible with all Universal Posts, if not prepared.

Page 78: Products Catalog - Neodent 2011

78

Torque Connection 1.2

Prosthetic Torque

Ratchet Driver

Neotorque Screw4.1mm

Neotorque Screw5.0 mm

Titanium Screw

Customizable Post 4.1mm

CustomizablePost 5.0mm

Angled Post(170 and 300)

3.3/ 4.1/ 4.3 / 5.0 mm

Implant Analogue

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

Closed tray Transfer

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

Open tray Transfer

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

32N.cm

32N.cm

32N.cm

Neotorque Screw

78

Demonstrative sequence of

Customizable Post Angled Post

• Available in Titanium;

• Cemented prosthesis;

• Angled Post presents 12 positions of fitting, and include

Titanium screw;

• Customizable Post without screw. It is recommended to

use the Neotorque screw.

External Hex

Page 79: Products Catalog - Neodent 2011

79

Ø 3.3

Ø 3.3

Ø 4.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

Ø 5.0

•Available in Titanium; •Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Select transfer according to the implant to be molded, as prosthetic planning.

Implant Transfer

108.012

Anti

-rota

tiona

lRota

tiona

l

108.013

108.038

108.029

108.066 (SF)

108.003

108.002

108.001

108.011

108.034

108.067 (SF)

108.006

Open tray Closed tray

2 mm 3 mm

Ø 3.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

4 mm

Angled Post

•Titanium screw included;•To torque, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Anti-rotational.

114.025 114.026 114.027

114.016 114.017 114.018

114.049 114.050 114.051

114.071 114.072 114.073

170

114.009 114.010300

Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

ImplantAnalogue

101.002 101.001

Titanium Brass

101.004 101.003

101.028 101.024

101.006 101.005

•Available in Brass and Titanium;•Replica of implant platform;•For prosthesis construction and/or prosthetic planning.

Ø 4.1 para Ø 5.0

Ø 4.1 para Ø 6.0

Ø 5.0 para Ø 6.0

•To unitary elements, select Neotorque Screw;•Screw not included;•To installation, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

CustomizablePost

114.029

114.030

114.035

Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

Hex Screw

116.188 116.001

116.189 116.003

116.180 116.002

Neotorque Titanium

• Observe indicated torque;• Use Torque Connection 1.2mm (105.005);

• To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Page 80: Products Catalog - Neodent 2011

80

Analogue3.3 mm

Analogue4.1 mm

Analogue4.3 mm

Analogue5.0 mm

UCLA3.3 mm

UCLA4.1 mm

UCLA4.3 mm

UCLA5.0 mm

Torque Connection 1.2

Prosthetic Torque Ratchet Driver

32N.cm

Neotorque Screw

Closed Tray Transfer

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

Open Tray Transfer

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

80

Demonstrative sequence of

UCLA

•Prosthetic component directly over the implant hex;

•For screw-retained or cemented prosthesis;

•Available in Rotational or Anti-Rotational;

- Tilite and CoCr: overcastting;

- Castable: casting;

- Titanium: Provisional or Cemented Prosthesis

- Gold: Overcasting with high melting range leagues.

•With Titanium and Neotorque screw;

•For unitary elements, select Neotorque screw.

External Hex

Page 81: Products Catalog - Neodent 2011

81

108.011

108.034

Ø 3.3

Ø 3.3

Ø 4.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

Ø 5.0

Implant Transfer

108.012

Anti

-rota

tiona

lRota

tiona

l

108.013

108.038

108.029

108.066 (SF)

108.003

108.002

108.001

108.067 (SF)

108.006

Open Tray Closed Tray

116.003

116.002

116.001Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

Hex Screw

116.188

116.189

116.180

Neotorque Titanium

Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

ImplantAnalogue

101.002

Titanium

101.001

Brass

101.004 101.003

101.028 101.024

101.006 101.005

•Available in Brass and Titanium;•Replica of implant platform;•For prosthesis construction and/or prosthetic planning.

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Ø 3.3

Ø 3.3

Ø 4.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

Ø 5.0

UCLA

Anti

-rota

tiona

lRota

tiona

l

118.204

118.097

118.009

118.040

118.212

118.235

118.237 118.006

118.101

118.004

118.001

CastableCobalt-Chromium

(Cocr)

118.008

NobleTitanium

118.205

118.152

118.030

118.211

118.234

118.236 118.007

118.119

118.005

118.002

•Available in Titanium; •Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Select transfer according to the implant to be molded, as prosthetic planning.

Page 82: Products Catalog - Neodent 2011

82

Mini BallAttachment

4.1

Mini BallAttachment

4.3

Mini BallAttachment

5.0

Prosthetic Abutment Driver

Prosthetic Torque Ratchet Driver

Straightpositioner

Positioner70

Positioner140

O’ring with Cylinder

Protection Disk

32N.cm

82

Demonstrative sequence of

Mini Ball Attachment

•Available in Titanium;

•Application of Nitride Titanium coating to increase the

wear resistance;

•Directly over the implant;

•It´s recommended capture the components in patient’s

mouth, one by one;

•O’ring with protection disc;

•See the demonstrative sequence of Mini Ball Attachment

on page 126.

External Hex

Protection Disk Positioner

Page 83: Products Catalog - Neodent 2011

83

102.060 102.061 102.062

102.063 102.064 102.065

102.066 102.067 102.068

Mini BallAttachment

2 mm

Ø 4.1

Ø 4.3

Ø 5.0

3 mm 4 mm

•Select according to mucosa height;•To installation, use Prosthetic Abutment Driver (105.009);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Castable BallAttachment

•Casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.

102.078

straight, 70 and 140

Positioners

•Available in polymer;•Defines the correct distance between Attachment Ball and O’ring;•Corrects the parallelism between implants;•Essential for O’ring capturing.

102.076

102.073

102.077

O’ring with Cylinder

Mini O’ring

Protection Disk

102.075

O’ringRemover

O’ringMount

104.044

104.043

•Digital Driver with function of O’ring replacing to the cylinder.

•Digital Driver with function of O’ring placement to the cylinder.

•Available in Titanium (cylinder);•Available in polymer (O’ring);•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;

•Not autoclavable.

•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;

•Not autoclavable.

•Package with 10 units.

Page 84: Products Catalog - Neodent 2011

84

INTERNAL HEX

Inte

rna

l thre

ad

Ø 1

.6

•Mini Conical Abutment II Plus (multiple)

•UCLA CoCr II Plus (single)

•Conical Abutment II Plus (single)

•Angled Conical Abutment II Plus (multiple)

•Universal Post II Plus •Angled Post II Plus 17°

and 30° •UCLA CoCr II Plus

(single) •UCLA Titanium II Plus

(single)

•Attachment Mini Ball II Plus

•Angled Conical Abutment II Plus

•Conical Abutment II Plus•Cylinder and Ext. Distal

Bar

Passive Fitting Technique•Castable – Mini Abutment

Cylinder •Titanium – Mini Abutment

Cylinder •Brass – Mini Abutment

Cylinder

3.75, 4.3 and 5.0 mm

4.3 and 5.0 mm

Implant diameter

Diameter of Prosthetic Platform

Screw-retained Prosthesis

CementedProsthesis Overdenture Protocol

Platform diameter

2.5 mm

HEXAGON

2.6 mm

COMPONENTS INDICATION TABLE

Deep internal interface which provides more stability and resistance between screw and component.

Page 85: Products Catalog - Neodent 2011

85

I n t e r n a lH e x

•Prosthetic components with reduced platform in relation to

the implant (Switching Platform);

•Installation driver with tweezers to increase the transport

security and the implant placement;

•Cervical microretentions to bone tissue maintenance;

•Unique prosthetic sequence independent of the implant

platform diameter.

Cervical micro-retentions.Prosthetic components with reduced platform in relation

to the implant(Switching Platform).

Page 86: Products Catalog - Neodent 2011

86

3.75mm

5.0mm

Init

ial

Dri

ll

Tit

am

ax

Dri

ll 2

.0

Pil

ot

2/3

Tit

am

ax

Dri

ll 3

.0

Pil

ot

3/3

.75

Tit

am

ax

Dri

ll 3

.15

Co

un

ters

ink

II

4.3

Tit

am

ax

Dri

ll 3

.8

Tit

am

ax

Dri

ll 4

.3

Co

un

ters

ink

II

5.0

Optional

Drill Sequence

•Cylindrical implant with Internal Hex interface;

•NeoPoros Surface;

•Double thread (faster installation and less trauma);

•High cutting capacity;

•Suitable for bones type I and II and areas of block grafting;

•Cover screw not included;

•Unique prosthetic interface for all implant diameters;

•Perforation rotation: 800-1200 rpm;

•Installation rotation: 30 rpm.

Product Characteristics:

Prosthetic components with reduced platform in relation to the implant (Switching Platform).

5.0

3.8

Page 87: Products Catalog - Neodent 2011

87

11.0 mm9.0 mm7.0 mm 13.0 mm 15.0 mm

Ø 3.75

Ø 5.0

109.462 109.463 109.464 109.465 109.466

109.474 109.475 109.476 109.477

Platform(4.3)

Cover Screw

117.014

Healings

4.0 mm3.0 mm2.0 mm

106.176 106.177 106.178

•Use Digital Driver 1.2mm (104.007) for installation;

•Do not exceed torque of 10 N.cm.

I n t e r n a lH e x

Page 88: Products Catalog - Neodent 2011

88

Product Characteristics:

•Conical implant with Internal Hex interface;

•NeoPoros Surface;

•Suitable for bones type III and IV and pos-extracting

installation;

•Cover screw not included;

•Unique prosthetic interface for all implant diameters;

•Perforation rotation: 500-800 rpm;

•Installation rotation: 30 rpm.

4.3mm

5.0mm

Init

ial

Dri

ll

Alv

im D

rill

2.0

Alv

im D

rill

3.5

Alv

im D

rill

4.3

Co

un

ters

ink

II

4.3

Alv

im D

rill

5.0

Co

un

ters

ink

II

5.0

Optional

Drill sequence

Prosthetic components with reduced platform in relation to the implant (Switching Platform).

5.0

3.8

Page 89: Products Catalog - Neodent 2011

89

Ø 4.3

Ø 5.0

10.0 mm 13.0 mm 16.0 mm

109.478 109.479 109.480

109.481 109.482 109.483

I n t e r n a lH e x

Cover Screw

117.014

Healings

4.0 mm3.0 mm2.0 mm

106.176 106.177 106.178

•Use Digital Driver 1.2mm (104.007) for installation;

•Do not exceed torque of 10 N.cm.

Page 90: Products Catalog - Neodent 2011

90

Demonstrative sequence of

Conical Abutment II PlusAngled Conical Abutment II Plus

Torque

Connection 1.2mm

Prosthetic Torque

Ratchet Driver

Prosthetic Abutment

Driver

Conical Abutment

II Plus

Angled Conical

Abutment II Plus

Prosthetic Torque

Ratchet Driver

Conical Abutment Analogue 4.1

Protective Cylinder of

Conical Abutment 4.1

Conical Abutment Cylinder 4.1

Ca

sta

ble

Tit

an

ium

Co

Cr

20N.cm

•Available in Titanium;

•Minimum interocclusal space of 6.1mm from the

mucosa level;

•Conicality 15°;

•Single screw-retained prosthesis (anti-rotational);

•Concept Switching Platform;

•Compatible components with implants diameter

(Ø 3.75, Ø 4.3 and Ø 5.0);

•The cylinders come with Neotorque screw, except

the castables, that comes with Titanium screw.

Conical Abutment

Transfer 4.1Closed tray

Conical AbutmentTransfer 4.1Open tray

Torque

Connection 1.2mm

90

Internal Hex

Page 91: Products Catalog - Neodent 2011

91

106.051

Protective Cylinder ofConical Abutment

108.035

108.020

108.075

108.018

101.027

ConicalAbutment Analogue

Open tray

Closedtray

Titanium Neotorque

116.004 116.231

Castable

Rota

tio

na

l

Anti

-rota

tio

na

l

Anti

-rota

tio

na

l

Rota

tio

na

l

Titanium CoCr

Conical AbutmentCylinder II Plus

1.0 mm 2.0 mm

Ø 4.1Ø 4.1

Ø 4.1

Ø 4.1

2.0 mm 3.0 mm3.0 mm 4.0 mm

ConicalAbutment II Plus

Angled ConicalAbutment II Plus 170

115.184 115.203115.185 115.204115.186 115.205

118.106

118.104

118.107

118.105

118.233

118.232

•To torque, use Prosthetic Abutment Driver (105.009);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);

•Single screw-retained prosthesis (anti-rotational).

• To torque, use Torque Connection 1.2mm (105.005);

• To torque control, use Prosthetic Torque Ratchet Driver (104.026);

• Observe sequence and indicated torque;•For multiple prosthesis (rotational).

•Available: Titanium: Provisional prosthesis; Tilite and CoCr: Overcasting; Castable: Casting.•Screw included;•To screw torque, use Torque Connection 1.2mm (105.005);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Available in Brass and Titanium;•Replica of implant platform or prosthetic component;

•For prosthesis construction or prosthetic planning.

•Available in Titanium;•Used to protect the component during the prosthesis construction;

•To installation, use Digital Driver 1.2mm (104.007).

•Available in Titanium;•Component with molding function by prosthesis construction;

•For open tray or closed tray technique.

ConicalAbutment Transfer

Cylinder Screw ofConical Abutment

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

I n t e r n a lH e x

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Page 92: Products Catalog - Neodent 2011

92

Demonstrative sequence of

Mini Conical Abutment II Plus

Mini ConicalAbutment II Plus

Prosthetic Abutment Driver

Prosthetic TorqueRatchet Driver

Mini Conical AbutmentOpen Tray Transfer

Mini ConicalAbutmentClosed Tray Transfer

Mini ConicalAbutment Analogue

Protective Cylinderof Mini Conical

Abutment

Mini Conical Abutment Cylinder

Tit

an

ium

Ca

sta

ble

Torque Connection 1.2mm

Prosthetic Torque Ratchet Driver

No

ble

/ C

oC

r

20N.cm

•Minimum interocclusal space of 4.4mm from the

mucosa level;

•Screw-retained and multiple prosthesis (rota-

tional);

•Conicality 20°;

•Concept Switching Platform;

•Compatible component with implants diameter II

Plus (Ø 3.75, Ø 4.3 and Ø 5.0);

•The cylinders come with Neotorque screw, except

the castables, that comes with Titanium screw.

92

Internal Hex

Page 93: Products Catalog - Neodent 2011

93

118.112 118.113

Calcinable Titanium

118.206 118.209 118.210

Noble CoCr CoCrfor welding

Mini ConicalAbutment Cylinder

Ø 4.1

115.155

1 mm 2 mm

115.156 115.157 115.158

3 mm 4 mm

Mini ConicalAbutment II Plus

•To torque, use Prosthetic Abutment Driver (105.009);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Ø 4.1 106.054

Protective Cylinder of Mini Conical Abutment

•Available in Titanium;•Used to protect the component during the prosthesis construction;

•To installation, use Digital Driver 1.2mm (104.007).

Ø 4.1 101.020

Mini ConicalAbutment Analogue

•Available in Titanium;•Replica of prosthetic component platform;

•For prosthesis construction or prosthetic planning.

•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting; Gold alloy: overcastting with high melting range leagues.•Screw included;•To screw torque, use Torque Connection 1.2mm (105.005);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);

•Rotational for screw-retained multiple elements.

Ø 4.1

Cylinder Screw of Mini Conical Abutment

Titanium Neotorque

116.037 116.227

116.036

Ø 4.1 108.022 108.068

Mini ConicalAbutment Transfer

ClosedTray

Short Screw

Multifunctional

•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Rotational.

108.021

OpenTray

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

I n t e r n a lH e x

Page 94: Products Catalog - Neodent 2011

94

Demonstrative sequence of

Universal Post II Plus

20N.cm

Universal Post Transfer

Prosthetic Torque Ratchet Driver

Universal Post II Plus

Neotorque Screw

Torque Connection 1.2

Universal Post Analogue

Universal Post

Cylinder Provisional

Universal Post

Cylinder Castable

Ø4.5

Ø4.5

Prosthetic Torque Ratchet Driver

•Available in Titanium;

•Cemented prosthesis;

•The Universal Post can be prepared according

to circunstances, and, in this case, the prosthetic

sequence can not be used;

•Compatible component with implants diameter II

Plus (Ø 3.75, Ø 4.3 and Ø 5.0);

•Screw not included. For single elements, use

Neotorque Screw;

•Available in two heights of cemented area: 4 or 6mm.

Ø3.8

Ø4.5

4 ou 6

Transmucous

Ø4.5 Ø4.5 Ø4.5

94

Internal Hex

Universal Post

Cylinder Alumina

Page 95: Products Catalog - Neodent 2011

95

•Available in polymer;•Component with molding function by prosthesis construction;

•For closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;

•Anti-rotational.

1 mm

4 m

m

4 m

m

4 m

m

4 m

m2 mm

6 m

m

6 m

m 6 m

m

6 m

m

Ø4.5

Ø 4.5

Ø 4.5

Ø 4.5

3 mm

Universal Post

UniversalPost Analogue

UniversalPost Set

•Available in Titanium;•Replica of prosthetic component platform;

•For prosthesis construction or prosthetic planning.

•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.

114.123 114.124 114.125

114.126 114.127 114.128

108.045

108.044

UniversalPost Transfer

101.041

101.040

108.062

108.063

•Available in: Acrylic: for provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.•Cemented prosthesis;•Compatible for all Universal Posts, when not prepared.

4 m

m6

mm

Ø 4.5

118.188 118.183 118.194

118.189 118.184 118.195

ProvisionalAlumina Castable

UniversalPost Cylinder

Neotorque Titanium

Hex ScrewII Plus

116.226 116.224

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Page 96: Products Catalog - Neodent 2011

96

Demonstrative sequence of

Angled Post II Plus

•Available in Titanium;

•Cemented prosthesis;

•With 6 fitting positions;

•Titanium screw included.

Prosthetic Torque Ratchet Driver

Torque Connection 1.2 mm

Angled Post II Plus

Transfer II Plus

Open Tray

Transfer II Plus

Closed Tray

Analogue II Plus

20N.cm

96

Internal Hex

Page 97: Products Catalog - Neodent 2011

97

2 mm 3 mm

Ø 4.3

Ø 5.0

4 mm

AngledPost II Plus

•Available in Titanium;•Component with molding function by prosthesis construction;

•For open tray or closed tray technique.

114.171 114.172 114.173170

114.174 114.175300

Analogue II Plus

101.032

101.034

Implant Transfer

Anti

-rota

tiona

l

108.046 108.047

Open TrayClosed Tray

•Available in Brass;•Replica of implant platform;•For prosthesis construction or prosthetic planning.

•To torque, use Torque Connection 1.2mm (105.005);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);

•Anti-rotational.

Page 98: Products Catalog - Neodent 2011

98

Demonstrative sequence of

UCLA II Plus

Analogue II Plus

UCLA II Plus UCLA II Plus

Co

Cr

Tit

an

ium 20

N.cm

Torque Connection 1.2

Prosthetic Torque Ratchet Driver

Neotorque Screw

•Prosthetic component directly over the implant;

•For screw-retained or cemented prosthesis;

•Available in rotational or anti-rotational models;

•Available in:

-CoCr: overcasting;

-Titanium: provisional or cemented prosthesis;

•Screw not included;

•For unitary elements, select Neotorque screw.

Transfer II Plus

Open Tray

Transfer II Plus

Closed Tray

Internal Hex

98

Page 99: Products Catalog - Neodent 2011

99

UCLA II Plus

Anti

-rota

tiona

lRota

tiona

l

118.214

118.213

Cobalt-Chromium (Cocr)

118.185

Titanium

116.224

Hex Screw II Plus

116.226

Neotorque Titanium

Ø 4.3

ImplantAnalogue II Plus

101.032

•Available in Brass;•Replica of implant platform;•For prosthesis construction or prosthetic planning.

•Available in Titanium;•Component with molding function by prosthesis construction;

•For open tray or closed tray technique;•Anti-rotational.

Implant Transfer

108.046 108.047

Open TrayClosed Tray

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Page 100: Products Catalog - Neodent 2011

100

Demonstrative sequence of

Mini Ball Attachment II Plus

Mini Ball Attachment

II Plus

•Available in Titanium;

•Application of Nitride Titanium coating for

increased the wear resistance;

•Directly over the implant;

•It´s recommended capture the components in

patient’s mouth, one by one;

•Obligatory to use positioner for capture;

•O’ring with protection disc;

•See the demonstrative sequence on page 126.

Prosthetic

Abutment Driver

Prosthetic Torque Ratchet Driver

StraightPositioner

Positioner 70

Positioner140

O’ring with Cylinder

Protection Disk

32N.cm

100

Protection Disk Positioner

Page 101: Products Catalog - Neodent 2011

101

102.090 102.091 102.092

Mini Ball Attachment II Plus

2 mm 3 mm 4 mm

•Select according to mucosa height; •To installation, use Prosthetic Abutment Driver (105.009);

•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

CastableBall Attachment

•Casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.

102.078

straight, 70 and 140

Positioners

•Available in polymer;•Defines the correct distance between Attachment Ball and O’ring;•Corrects the parallelism between implants;•Essential for O’ring capturing.

102.076

102.073

102.077

O’ring with Cylinder

Mini O’ring

Protection Disk

102.075

O’ringRemover

O’ringMount

104.044

104.043

•Digital Driver with function of O’ring replacing to the cylinder.

•Digital Driver with function of O’ring placement to the cylinder.

•Available in Titanium (cylinder);•Available in polymer (O’ring);•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;

•Not autoclavable.

•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;

•Not autoclavable.

•Package with 10 units.

Page 102: Products Catalog - Neodent 2011

102

Page 103: Products Catalog - Neodent 2011

103

Zygomatic Implants

Page 104: Products Catalog - Neodent 2011

104

Product Characteristics:

• Cylindrical implant;

• Morse Taper interface, with different dimensions of the

conventional implants (same dimensions of WS Titamax

Implant) or External Hex 4.1mm;

• Smooth surface;

• Pre-mounted;

• Cover screw not included;

• Double thread in CM Zygomatic version;

• It is indicated to use the Transepithelial Abutment according

to the prosthetic interface.

Observation: This technique requires specific accreditation.Information on www.neodent.com.br.

Ø 4.4mm

Nom

ina

l leng

th

Ø 3.9mm

Hex 2.7 m

mØ 4.1 mm

0.7 mm

Ø 3

.0 m

m

Page 105: Products Catalog - Neodent 2011

105

Zygomatic CMCover Screw

117.016

30.0 mm

30.0 mm

35.0 mm

35.0 mm

40.0 mm

40.0 mm

45.0 mm

45.0 mm

47.5 mm

47.5 mm

50.0 mm

50.0 mm

52.5 mm

52.5 mm

109.522 109.523 109.524 109.525 109.526 109.527 109.528

External HexCover Screw

109.460 109.450 109.451 109.452 109.461 109.453 109.454

117.018

4.1 mm

External Hex

Morse Taper

•Use Digital Driver 0.9mm (104.039) to the

installation of Cover Screw;

• Do not exceed torque of 10 N.cm.

•Use Digital Driver 1.2mm (104.007) to the

installation of Cover Screw;

•Do not exceed torque of 10 N.cm.

Page 106: Products Catalog - Neodent 2011

106

Transepithelial Abutment

External HexTransepithelial

Abutment

Morse TaperTransepithelial

Abutment

Prosthetic Abutment Driver

Transepithelial AbutmentOpen Tray Transfer

Transepithelial Abutment Analogue

Protective Cylinder ofTransepithelial Abutment

Torque Connection 1.2mm

Prosthetic TorqueRatchet Driver

Prosthetic Torque

Ratchet Driver

20N.cm

Transepithelial AbutmentCylinder

CoCr

32N.cm

Demonstrative sequence of

106

Prosthetic Abutment

Transepithelial AbutmentOpen Tray Transfer

Transepithelial Abutment Analogue

Protective Cylinder ofTransepithelial Abutment

Torque Connection 1.2mm

Prosthetic TorqueRatchet Driver

Transepithelial Abutment

323232N.cmN.cmN.cmN.cmN.cmN.cm

•Available in Titanium;

•Minimum interocclusal space of 4.5mm;

•Screw-retained and multiple prosthesis;

•Exclusive for Zygomatic Implants;

•CM model compatible with WS Titamax Implant.

Castable

Page 107: Products Catalog - Neodent 2011

107

Morse TaperTransepithelial Abutment

CylinderTransepithelial Abutment

Castable CoCr

118.034 118.254

•Available in: Castable: casting; CoCr: overcasting.•With screw.

•To installation, use Prosthetic Abutment Driver (105.009);

•Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Cylinder Screw

116.004 116.231

NeotorqueTitanium

TransferTransepithelial Abutment

108.026

•Available in Titanium; •For Open tray technique; •Rotational.

AnalogueTransepithelial Abutment

101.018

•Available in Titanium; •Replica of transepithelial abutment;

•To the prosthesis confection or prosthetic planning.

Protective CylinderTransepithelial Abutment

106.056

• Available in Titanium;• Suitable to protect the component in mouth during the prosthesis elaboration;

• To installation, use Digital Driver 1.2mm (104.007).

115.023 115.024 115.025

External HexTransepithelial Abutment

3 mm 4 mm 5 mm

115.172 115.173 115.174

3 mm 4 mm 5 mm

•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);

•To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Page 108: Products Catalog - Neodent 2011

108108

Product Characteristics:

• Case in autoclavable polymer;

• Drills and connections for Zygomatic Implants –

External Hex and Morse Taper;

• Insert not included (KAVO).

Observation: This technique requires specific accreditation.

Information on www.neodent.com.br

Page 109: Products Catalog - Neodent 2011

109

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

110.214

104.042

105.067

105.069

103.190

103.191

103.192

103.193

103.197

103.208

128.016

124.004

129.011

129.012

104.007

104.039

Zygomatic Surgical Kit Case

Zygomatic Installation Driver

Zygomatic Contra-Angle Connection

Connection for exchange of Zygomatic Drills

Zygomatic Spherical Drill 2.9 Plus

Zygomatic Twist Drill 2.7 Plus

Zygomatic Pilot Twist Drill 2.7/3.3 Plus

Zygomatic Twist Drill 3.3 Plus

Zygomatic Countersink Drill CM Plus

Zygomatic Pilot Twist Drill 3.3/3.7 Plus

Zygomatic Height Measurer CM

Zygomatic Labial Protector

Zygomatic Bicortal Probe

Zygomatic Probe

Short Digital Driver 1.2

Short Digital Driver 0.9

Items contained in Zygomatic Kit

* illustrative image

Page 110: Products Catalog - Neodent 2011

110

Page 111: Products Catalog - Neodent 2011

111

Surgical Techniques

Page 112: Products Catalog - Neodent 2011

112

•Specific composition for the technique;

•Case in autoclavable polymer;

•Drivers, connections and surgical

instruments necessary to the Neoguide

technique;

•Technique suitable for virtual planning

and flapless surgery.

Obs.: This technique requires specific accreditation.

Information on www.neodent.com.br

112

•Specific composition for the technique;

•Case in autoclavable polymer;

Characteristics of Neoguide Kit

Page 113: Products Catalog - Neodent 2011

113

Items included in Neoguide Surgical Kit

Neoguide Surgical Kit Case

Neoguide Mucosal Punch for Contra-Angle

Neoguide Mucosal Punch Manual

Neoguide Drill 1.3

Neoguide Drill 2.0

Neoguide Drill 2.8

Neoguide Drill 3.0

Neoguide Drill 3.3

Neoguide Pilot Drill 3.5

Neoguide Pilot Drill 3.75

Neoguide Pilot Drill 4.0

Narrow Neoguide Mucosal Punch for Contra-angle

Narrow Neoguide Mucosal Punch Manual

Narrow Neoguide Pilot Drill

Neoguide CM Connection 3.5 for Contra-angle

Neoguide CM Connection 3.75 for Contra-angle

Neoguide CM Connection 4.0 for Contra-angle

Neoguide CM Connection 3.5 for Ratchet

Neoguide CM Connection 3.75 for Ratchet

Neoguide CM Connection 4.0 for Ratchet

Narrow Neoguide CM Connection for Contra-angle

Narrow Neoguide CM Connection for Ratchet

Digital Driver 1.2 Short

Digital Driver for Torque Connection

Neoguide Drill Guide 2.0

Neoguide Drill Guide 2.8

Neoguide Drill Guide 3.0

Neoguide Drill Guide 3.3

Neoguide Guide Clamp

Narrow Neoguide Drill Guide 2.0

Narrow Neoguide Drill Guide 2.8

Neoguide Guide Stabilizer

Narrow Neoguide Guide Stabilizer

Surgical Torque Ratchet Driver

Titanium Tweezers

Implant Guide 3.5 Neoguide

Implant Guide 3.75 Neoguide

Implant Guide 4.0 Neoguide

110.250

103.180

103.181

103.179

103.183

103.184

103.185

103.186

103.187

103.188

103.189

103.194

103.195

103.196

105.079

105.080

105.081

105.082

105.083

105.084

105.091

105.092

104.007

104.005

125.033

125.034

125.035

125.036

125.032

125.039

125.040

125.041

125.059

104.027

129.001

125.029

125.030

125.031

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

4

1

1

1

1

1

1

5

5

5

Reg

ular

Co

mp

lete

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

* illustrative im

age

Page 114: Products Catalog - Neodent 2011

114

Neoguide Drills

•Available in surgical stainless steel;•Twist Drill for Ø1.3 and Ø2.0 and Tri-Spade for another diameters;

•Drill 1.3 for perforation in the fixing tubes of Surgical Guide;

•Markings from 7 to 17mm.

103.179 103.183 103.184 103.185 103.186

Ø1.3 Ø2.0 Ø2.8 Ø3.0 Ø3.3

103.187 103.188 103.189

Neoguide Pilot Drills

•Available in surgical stainless steel coated in carbon, which provides a lower friction coefficient;

•Preparation of the bone crest for seating of cervical third in CM Titamax Implants;

•Indicated for bones type I and II.

Ø3.5 Ø3.75 Ø4.0

125.029

125.032

125.030 125.031

Ø3.5 Ø3.75 Ø4.0

Mucosal Punch

•Surgical stainless steel coated in carbon, which provides a lower friction coefficient;

•Guided circular incision for mucosa removing;•Rotatory Punch – used with contra-angle;•Manual Punch – used manually with Digital Drivers for Torque Connections (104.028);

•Also indicated as circular scalpel.

•Available in Titanium; •Its function is to stabilize the prototyped guide, after the installation of each implant.

103.180

125.041

103.194

125.059

103.181

103.195

Contra-angle Manual

Neoguide Implant Guide

•Available in Titanium;•Guide for installation of CM Implants in Neoguide Technique;

•The colors indicate the CM Implant diameter.

Guide Clamp

Stabilizer

•Titanium;•Pin for fix the surgical guide over the ridge;•Effective length of 12mm and Ø 1.3mm.

Neoguide Kit

Neoguide Kit

Neoguide Kit

NarrowNeoguide Kit

NarrowNeoguide Kit

NarrowNeoguide Kit

103.196

DRILL PLUS: Count with the application of a thin pellicle with carbon basis, which promotes low friction coefficient and reduction of the heat generated on osteotomy.

Page 115: Products Catalog - Neodent 2011

115

Drill Guide

•Use the corresponding drill to the Surgical Guide diameter (colors);

•Embedded in the washers of Surgical Guide;•The colors indicate the CM Implant diameter.

125.033Neoguide Kit

125.039NarrowNeoguide Kit

125.034

125.040

125.035 125.036

Ø2.0 Ø2.8 Ø3.0 Ø3.3

•Available in Titanium;•Used with Mini Conical Abutment Ana-logue for obtain the work model;

•3 spreaders with 1mm of height included;•Technique for prosthesis construction before the surgery.

NeoguidePositioner

101.054

Neoguide CM Connection for Contra-angle

Neoguide CM Connectionfor Ratchet

•Available in Titanium; •To insert the implant using motor and contra-angle.

•Available in Titanium; •For manual insertion of the implant using Surgical Torque Ratchet Driver (104.027).

105.079

105.082

Neoguide Kit

Neoguide Kit

105.091

105.092

NarrowNeoguide Kit

NarrowNeoguide Kit

105.080

105.083

105.081

105.084

3.5

3.5

3.75

3.75

4.0

4.0

Page 116: Products Catalog - Neodent 2011

116

The Neoshape System combines the new technologies in this segment, in order to guarantee precision and quality in the production of the countless prosthetic techniques available in the market. This novelty broadens horizons, offering excellence, adaptation, precision and esthetics in a customized manner, with digital planning.

With it, the prosthesis technician can plan in the PC screen, in a tri-dimensional manner, all the esthetics and functional details of the prosthesis solutions of the laboratory’s daily routine.

Following the completion of the virtual polishing, a digital file is forwarded online to Neodent’s milling center. There, the information of each received case is managed. Next, the file is sent

to last generation equipments, which accurately reproduce the 3D drawings by milling, assuring precision in adaptation and finishing.

The Neoshape System offers, along with its 3D modeling software, a comprehensive library of prosthetic interfaces, including: rotational external hex, anti-rotational external hex, internal hex, Morse taper, Mini Conical Abutment and Universal Post, which can be directly attached to the implant.

Regardless the choice of material for prosthesis fabrication, the mechanic properties and the quality assurance are guaranteed by raw-materials with international quality standards, supplied by controlled origin sources, reinforcing our ethical commitment.

2. Scanning

WORK OF PROSTHESIS

TECHNICIAN

4. Fabrication of the customized piece at the Neodent Milling

Center

NEODENT WORK

3. CAD Modeling with 3D planning software

WORK OF PROSTHESIS

TECHNICIAN

5. Concluded prosthesis with

application of porcelain

WORK OF PROSTHESIS

TECHNICIAN

DENTIST WORK

1. Patient

CAD CAM SYSTEM

Page 117: Products Catalog - Neodent 2011

117

PROSTHETIC SOLUTIONS

OF THE NEOSHAPE

SYSTEM

Customized Abutment

Unitary Over Intermediate

External Hex, Internal Hex

and Morse Taper

Multiple Over Tooth

External HexUnitary Multiple MultipleUnitary

Universal Post, Customized Post, Conical Abutment, GT

Abutment

Customized Post, Mini Conical

Abutment

Infrastructure

Copings

InfrastructureMini Conical

Abutment

Page 118: Products Catalog - Neodent 2011

118

Machining of copings virtually planned.

Page 119: Products Catalog - Neodent 2011

119

Scanning of work model and opposite arch.

Molding of the elements to be restored and opposite arch.

Industrial machining. Quality control at micrometric level.

Virtual planning.

For work over teeht, the plaster model shall be die-cast and have its preparation margins exposed and delimited. For over implant works, the model shall be cast with artificial gingiva.

Different possibilities of techniques and materials.

3

1

5

4

2

6

CAD CAM SYSTEM

Page 120: Products Catalog - Neodent 2011

120

Passive Fitting

Technique which allows the passive fitting

without welding through Titanium cylinder

cementation in the metallic structure. Used for

multiple prosthesis and results in laboratorial

working time reduction.

Demonstrative sequence of

120

Page 121: Products Catalog - Neodent 2011

121

118.083

118.250

118.086

118.174

118.089

118.081

118.248

118.084

118.173

118.087

118.082

118.249

118.085

118.172

118.088

Castable

Castable

Castable

Castable

Ø4.1

Ø5.0

Brass

Brass

Brass

Brass

Titanium

Titanium

Titanium

Titanium

Cylinders Passive FittingMini Conical Abutment

Cylinders Passive FittingMicro CM Abutment

Cylinders Passive FittingTransepithelial Abutment

CylindersPassive Fitting GT

Work Screw Passive Fitting

4.1 mm 5.0 mm

116.086 116.087

•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005);

•For torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005);

•For torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005); •For torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005);

•For torque control, use Prosthetic Torque Ratchet Driver (104.026).

•To use in laboratory.

Page 122: Products Catalog - Neodent 2011

122

1 Regularization of the alveolar ridge. 2 Surgical perforation concluded, checking the correct distance of the Distal Implant in relation to the mentual foramen with a 7mm flag.

3 Installation of 5 CM Cortical Titamax Implants Ø3.75.

4 Installation of CM Mini Abutments. 5 Installation of squared transfers, replacing by the short screws (mini abutment cylinder screw) and making the union of transferents with acrylic resin.

6 Positioning of the Multifunctional Guide to obtain the intermaxillary relations. Make the union with acrylic resin of the transferents. After union, inject fluid silicon to the soft tissue impression.

7Removal of Multifunctional Guide and installation of Mini Abutment Analogues to the transferents.

8 Work model with artificial gingiva. 9 Castable Passive Fitting Cylinder, Brass Passive Fitting Cylinder and Titanium Passive Fitting Cylinder with slots and lower diameter than brass, compensating the casting contraction.

Passive Fiiting Demonstrative sequence of

122

Page 123: Products Catalog - Neodent 2011

123

1 0 Brass Cylinders are placed over the analogues and receive Castable Cylinders fixed with work screws.

1 1 1 2Casting ring with waxed infrastructure.

1 3

Casted infrastructure.

1 4Infrastructure adaptation over the model.

Final intraoral view.

1 5Observe area for cementation.

1 6

Cementation with Panavia® (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;

1 7Cementation with Panavia® (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;

Page 124: Products Catalog - Neodent 2011

124124

Demonstrative sequence of

Distal Bar

•Technique for facilitate mandibular rehabilitations

with Passive Fitting using a prosthesis type

implant-supported provisional protocol.

Ø 4.1

Ø 5.0

Distal BarCylinder

118.169

MiniAbutment

GT

118.170

118.171

•Available in Titanium;•Retentions to facilitate the acrylic resin union;

•Indicated torque: 10 N.cm;•To torque, use Torque Connection 1.2 (105.005).

Ø 4.1

Ø 5.0

Distal Bar

125.011

MiniAbutment

•Use in Distal Implants to strengthen the Cantilever.

GT

125.012

125.023

Page 125: Products Catalog - Neodent 2011

125

1 2GT Implant installed. 3Wear prosthesis, maintaining the integrity of posterior area.

4

Cylinders installation in Central Implants and of Distal Bar in posterior implants.

5Proof of the inferior prosthesis with wear (centrical occlusion position, without interference in cylinders).

6Placement of a rubber dam over the cylinders to the soft tissue protection.

7

Application of autopolymerizable acrylic resin in the cylinders.

8 9Acrylic resin application between the cylinders.

1 0

Application of inferior prosthesis in wear area, repositioning in mouth, patient in occlusion even your full polimerization.

Implant-supported provisional prosthesis concluded.

1 1

Remotion of inferior prosthesis after resin polimerization, cylinders captured.

Final intraoral posterior view.1 2Wear, finishing and polishing of inferior prosthesis with polishing protectors.

Page 126: Products Catalog - Neodent 2011

126

Mini Ball Attachment Demonstrative Sequence of

126

Page 127: Products Catalog - Neodent 2011

127

1 Construction of new total prosthesis

Lateral view of set.

2 Implants installed. 3 Components.

4 Attachment Ball installed. 5 Using of positioners to correct the parallelism between the Implants and determinate the correct distance between O’ring and Attachment.

6 Placement of protection disks.

Placement of O’rings.7 8 9Inferior view of alleviation.

10 First O’ring captured. 11

Proof of prosthesis to verify adaption without interference.

Second O’ring captured. 12

Page 128: Products Catalog - Neodent 2011

128

Page 129: Products Catalog - Neodent 2011

129

Bone Grafting and Orthodontic Anchorage

Page 130: Products Catalog - Neodent 2011

130130

* illustrative image

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Bone Grafting and Orthodontic Anchorage Case

Bone Grafting Manual Driver

Philips Connection for Manual Driver

Philips Connection for Contra-angle

Drill 1.6 for Contra-angle

Drill 1.3 for Contra-angle

Drill 1.1 for Contra-angle

Drill 1.6 for Straight Piece

Drill 1.3 for Straight Piece

Drill 1.1 for Straight Piece

Punch for Bone Grafting and Orthodontic Anchorage

Orthodontic Anchorage Driver

Contra-angle connection – Anchorage - Long

Contra-angle connection – Anchorage – Short

Ratchet Adaptor for contra-angle connections

110.227

104.018

105.063

105.023

103.045

103.079

103.044

103.043

103.078

103.042

103.207

104.033

105.039

105.040

105.025

Complete Kit:Bone Grafting and Orthodontic Anchorage

Page 131: Products Catalog - Neodent 2011

131

1

1

1

1

1

1

1

1

1

1

1

Bone Grafting and Orthodontic Anchorage Case

Bone Grafting Manual Driver

Philips Connection for Manual Driver

Philips Connection for Contra-angle

Drill 1.6 for Contra-angle

Drill 1.3 for Contra-angle

Drill 1.1 for Contra-angle

Drill 1.6 for Straight Piece

Drill 1.3 for Straight Piece

Drill 1.1 for Straight Piece

Punch for Bone Grafting and Orthodontic Anchorage

110.227

104.018

105.063

105.023

103.045

103.079

103.044

103.043

103.078

103.042

103.207

Bone Grafting Kit

1

1

1

1

1

1

1

1

1

Bone Grafting and Orthodontic Anchorage Case

Drill 1.3 for Contra-angle

Drill 1.1 for Contra-angle

Drill 1.3 for Straight Piece

Drill 1.1 for Straight Piece

Orthodontic Implant Driver

Long Connection

Short Connection

Ratchet Adaptor

110.227

103.079

103.044

103.078

103.042

104.033

105.039

105.040

105.025

Orthodontic Anchorage Kit

Page 132: Products Catalog - Neodent 2011

132

Expandedhead

Expanded Head

Standard Head

6 mm

Ø 1.5 mm

Ø 2.0 mm

Ø 2.0 mm Ø 3.0 mmØ 3.85 mm

Ø 1.5 mm

Ø 1.5 mm Ø 2.5 mmØ 3.70mm

Ø 2.0 mm

8 mm

8 mm

10 mm

10 mm

12 mm

12 mm

14 mm

14 mm

116.194

Screw forBone Grafting

•Available in Titanium;•Osseous block fixation;•Self-drilling.

116.196 116.198 116.199 116.200

116.203 116.205 116.207

116.210 116.211 116.212

116.214 116.215 116.216

116.213

116.209

7 mm5 mmBand

Ø 1.3mm

Ø 1.3mm

Ø 1.6mm

Ø 1.6mm

9 mm 11 mm

Low

Low

Medium

Medium

•Available in Titanium alloy according to ASTM-F136 (level V);

•Implants for orthodontic movement; •Self-drilling; •Collar height: -Low: 0mm; -Medium: 1mm;•Torque resistance up to 10 N.cm (Ø 1.3mm) and 20 N.cm (Ø 1.6mm).

109.484 109.485 109.486

Hex Size:2.7 mm

Hole Diameter: 0,7mm

109.487 109.488 109.489

109.493109.701 109.494 109.495

109.496109.702 109.497 109.498

Implants forOrthodontic Anchorage

1 m

m

132

Bone Grafting andOrthodontic Anchorage

Page 133: Products Catalog - Neodent 2011

133

•Available in stainless steel; •Manual installation of Orthodontic Anchorage Implants.

OrthodonticAnchorage Driver

104.033

Punch for Bone Grafting and Orthodontic Anchorage

103.207

•Available in stainless steel ; •Initial severance of cortical.

Connections and Adaptor Orthodontic Anchorage

•Connections for installation of Anchorage Implants with Ratchet or Contra-angle;

•Ratchet Adaptor for Contra-angle Connections(105.025).

105.040

Short

105.039

Long

105.025

Drills forOrthodontic Anchorage

•Available in surgical stainless steel; •Suitable for bones tipe I and II; •Markings referent to the implant length (5, 7, 9 and 11mm).

103.042

7 mm5 mm

9 mm11 mm

103.078 103.043

103.044

Ø 1.1mm Ø 1.3mm Ø 1.6mm

Straight piece

Contra-angle 103.079 103.045

OrthodonticAnchorage Driver

Page 134: Products Catalog - Neodent 2011

134

Philips Driver

Manual Driver

104.018

105.063

Straight Piece

105.023

Contra-angle

•Assists in handling of Philips Driver (105.063) and of Graver for Bone Grafting and Orthodon-tic Anchorage (103.207).

•Available in stainless steel; •Screw installation for bone grafting.

134

Bone Grafting andOrthodontic Anchorage

Page 135: Products Catalog - Neodent 2011

135

Package of Orthodontic Anchorage Implant. Cover removal to access the implant.

Capture of the implant with Orthodontic Anchorage Contra-angle Connection.

Installation of the implant with Contra-Angle Connections (105.039 or 105.040).

Insertion option of the implant manually, with Orthodontic Anchorage Driver (104.033) or with Ratchet and Ratchet Adaptor for Contra-angle Connections (105.025).

Implant installed.

1

3

5

2

4

6

•Resistance to torque until 10 N.cm (Ø1.3mm) and 20 N.cm (Ø1.6mm).

Page 136: Products Catalog - Neodent 2011

136

STERILISE

Sterilize on the eve of or in the day of procedure.

It is recommended, preferably, follow the method

of sterilization by steam autoclaving, and also the

parameters and procedures established in the

regulation BS EN ISO 17665-1:2006 Moist heat.

Requirements for the development, validation

and routine control of a sterilization process for

medical devices, or to proceed conforming to the

instructions manual from the manufacturer of the

autoclave.

WARNING: THE KITS ARE DAMAGED WHEN SEALED

WITH ADHESIVE TAPE.

DO NOT STERILIZE PRODUCTS MADE IN POLYMER AT

HOTHOUSE.

VALIDITY OF STERILIZATION: 7 to 15 days, since kept

in clean environment, dry and away from the sun.

HYGIENE

Kits Neodent and surgical instruments should be

properly cleaned after each use. Do not let them in

contact with moisture for prolonged periods.

1st Step: Disassemble piece (if applicable).

2nd Step: Immerge the whole piece in enzymatic

detergent with solution of 10%.

3rd Step: Wash in an ultrasonic washer for about 10

minutes.

4th step: Rinse with distilled water in abundance to

remove completely the solution residues, making

use of brushes.

5th step: Dry with paper towel or compressed air.

6th step: Realize visual inspection, observing if the

cleaning process has been successful.

If there is any dirt, the piece should be re-immersed

in detergent – 1st and 2nd steps -, and, if is necessary,

the cleaning should be done with the

help of a nylon brush for dental use (repeat the

rinsing and drying sequence).

7th Step: Select the package in accordance with

the sterilization process. Preferably use self-sealing

package of medical grade paper with laminated film.

IMPORTANT: Never store the material without

complete drying. Drying is very important to prevent

oxidations.

ATTENTION: Do not use not incrusted products (non-

enzymatic). They tend to darken the pieces and also

cause oxidation. The use of enzymatic liquid with

concentration higher than 10%, as well as drying of

pieces containing cleaning solution residues, helps

oxidation and must be avoided.

KitsNeodent

Page 137: Products Catalog - Neodent 2011

137

Surgical and Prosthetic Ratchets are removable and

with torque control.

The parallel indicators have different colors and numbering to indicate the exact size of the implant to

be used.

Drills with carbon treatment (Plus) which reduce friction during surgical procedure.

Surgical tweezers with self-locking of the implant

and milimeter scale for conference during

proceedings.

Great controlduring drilling.

Elimination of lateral cutting, reducing the warming during osteotomy.

Less heating and higher irrigation flow, less surgical trauma.

GASH

POLISHING PROPELLERS

TWIST DRILL

Page 138: Products Catalog - Neodent 2011

138138

Product Characteristics:

•Case in autoclavable polymer;

•Drivers, connections and surgical instruments

for Titamax Implants and External Hex Alvim,

Internal Hex and Morse Taper.

Obs.: Items contained in Surgical Kit are also

sold separately. Following, three surgical kits are

suggested: Initial, Intermediary and Advanced.

Page 139: Products Catalog - Neodent 2011

139

Items contained in Surgical Kit Ad

vance

d

Inte

rmed

iary

Init

ial

110.251

103.170

103.171

103.162

103.213

103.163

103.164

103.165

103.166

103.167

103.168

103.172

103.173

103.174

103.209

103.239

103.211

103.242

103.216

103.217

103.218

103.219

103.220

103.091

105.047

105.045

105.046

105.050

105.048

105.049

105.001

105.018

105.002

105.073

105.074

105.075

128.015

113.014

128.019

128.020

128.021

128.022

128.023

104.039

104.007

104.028

104.027

129.004

129.001

105.030

105.031

105.068

103.296

103.297

Surgical Kit Case

Initial Drill PLUS

Alvim Twist Drill 2.0 PLUS

Twist Drill 2.0 PLUS

Pilot Drill 2/3 PLUS

Twist Drill 2.8 PLUS

Twist Drill 3.0 PLUS

Twist Drill 3.15 PLUS

Twist Drill 3.3 PLUS

Twist Drill 3.8 PLUS

Twist Drill 4.3 PLUS

Alvim Drill 3.5 PLUS

Alvim Drill 4.3 PLUS

Alvim Drill 5.0 PLUS

Countersink Drill 3.3 PLUS

SF Countersink Drill 4.1 PLUS

Countersink Drill 4.3 PLUS

SF Countersink Drill 4.5 and 5.0 PLUS

CM Pilot Drill 2.8/3.5 PLUS

CM Pilot Drill 3/3.75 PLUS

CM Pilot Drill 3.3/4.0 PLUS

CM Pilot Drill 3.6/4.3 PLUS

CM Pilot Drill 4.3/5.0 PLUS

Extension Drill

Connection for TI Contra-angle 4.1 and 4.3

Short TI Ratchet Connection 4.1 and 4.3

Long TI Ratchet Connection 4.1 and 4.3

Contra-angle TI Connection 5.0

Short TI Ratchet Connection 5.0

Long TI Ratchet Connection 5.0

Short Hex Connection for Ratchet

Long Hex Connection for Ratchet

Hex Connection for Contra-angle

Short CM Connection for Ratchet

Long CM Connection for Ratchet

CM Connection for Contra-angle

Height Measurer CM

H.E. Long Mount 3.3

Parallel Indicators 2.8/3.5

Parallel Indicators 3.0/3.75

Parallel Indicators 3.3/4.0

Parallel Indicators 3.6/4.3

Parallel Indicators 4.3/5.0

Short Digital Driver 0.9

Short Digital Driver 1.2

Digital Driver for Contra-angle Connections

Surgical Torque Ratchet Driver

Depth Probe

Titanium Tweezers

Short Ratchet Connection II Plus

Long Ratchet Connection II Plus

Contra-angle Connection II Plus

Countersink Drill II Plus 4.3

Countersink Drill II Plus 5.0

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

* illustrative image

Page 140: Products Catalog - Neodent 2011

140140

Product Characteristics:

•Case in autoclavable polymer;

•Drivers, connections and surgical instruments

for CM Titamax Implants and WS Titamax

installation.

Obs.: Items contained in Surgical Kit are also sold separately. Descriptions are shown next.

Page 141: Products Catalog - Neodent 2011

141

Items contained in WS Kit

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

WS Surgical Kit Case

Initial Drill Plus

Twist Drill 2.0 PLUS

Twist Drill 2.8 PLUS

Twist Drill 3.0 PLUS

Twist Drill 3.3 PLUS

Twist Drill 3.8 PLUS

Twist Drill 4.3 PLUS

Twist Drill 5.3 PLUS

Extension Drill

Pilot Drill 2/3 PLUS

CM Pilot Drill 3.0/3.75 PLUS

CM Pilot Drill 3.3/4.0 PLUS

Pilot Drill 3.8/4.3 PLUS

CM Pilot Drill 4.3/5.0 PLUS

Pilot Drill 4.3/5.3 PLUS

CM Pilot Drill 5.3/6.0 PLUS

Short Digital Driver 1.2

Surgical Torque Ratchet Driver

Short Hex Connection for Ratchet

Long Hex Connection for Ratchet

Hex Connection for Contra-angle

WS Post 4.5x6x0.8 Prosthetic Selection

WS Post 4.5x6x1.5 Prosthetic Selection

WS Post 4.5x6x2.5 Prosthetic Selection

WS Post 4.5x6x3.5 Prosthetic Selection

Parallel Indicators 3.0/3.75

Parallel Indicators 3.3/4.0

WS Parallel Indicators 4.3/5.0

WS Parallel Indicators 5.3/6.0

Titanium Tweezers

Depth Probe

110.218

103.170

103.162

103.163

103.164

103.166

103.167

103.168

103.169

103.091

103.213

103.217

103.218

103.214

103.220

103.215

103.221

104.007

104.027

105.001

105.018

105.002

114.230

114.231

114.232

114.233

128.020

128.021

128.024

128.025

129.001

129.004

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

110.218

103.170

103.162

103.163

103.164

103.166

103.167

103.168

103.169

103.091

103.213

103.217

103.218

103.214

103.220

103.215

103.221

104.007

104.027

105.001

105.018

105.002

114.230

114.231

114.232

114.233

128.020

128.021

128.024

128.025

129.001

129.004

* illustrative image

Page 142: Products Catalog - Neodent 2011

142

Product Characteristics:

DRILLS PLUS: Counts upon the application

of a thin pellicle with carbon basis which

promotes reduced friction and reduction of

the heat generated in the osteotomy.

ATTENTION:

The drills suffer wear during their use.

Evaluate their cut effectiveness periodically

and observe the need for substitution to

avoid loss of implants.

16.0

13.0

10.011.5

8.0

1.0

Bone level2.0

142

13.0

10.0

5.0

17.015.0

6.0

7.09.0

11.0 13.0

Page 143: Products Catalog - Neodent 2011

143

InitialDrill Plus

103.170Ø 2.0

•Available in Surgical Stainless Steel;

•Cortical disruption;•Diameter of 2.0mm.

Alvim Drill Plus(Scaled)

•Available in surgical stainless steel and Zirconia;

•Instrumentation sequence of surgical alveolus for Alvim Implants.

103.174 103.255

103.173 103.254

103.172 103.253

SurgicalStainless Steel

SurgicalStainless Steel

SurgicalStainless Steel

SurgicalStainless Steel

SurgicalStainless Steel

Zirconia

Zirconia

Zirconia

Zirconia Zirconia

Ø 3.5

Ø 4.3

Ø 5.0

•Available in Surgical Stainless Steel and Zirconia;

•Its function is increase the surgical alveolus diameter, facilitating the next drill entry;

•Substitutes the Countersink Drill in use of the Morse Taper Implants.

Pilot Drill

103.216 103.272

103.218 103.274

103.219 103.275

103.220 103.276

103.213

103.217 103.273

103.214 103.270

103.215 103.271

2.8/3.5 mm

3.3/4 mm

3.6/4.3 mm

4.3/5 mm

2/3 mm

3/3.75 mm

3.8/4.3 mm

4.3/5.3 mm

103.221 103.2775.3/6 mm

Countersink Drill

•Available in Surgical Stainless Steel and Zirconia;

•Prepare of the bone crest for cervical third seating in Implants 3.3, 3.75, 4.0,4.5 and 5.0mm (external hex) and 4.3, 5.0mm (internal hex).

103.212 103.268

103.239 103.292

103.209 103.265

External Hex

Internal Hex

Ø 4.1(SF)

(SF)

Ø 3.3

103.211 103.267Ø 4.3

Ø 4.3

Ø 4.5/ Ø 5.0

Ø 5.0

103.296 103.298

103.297 103.299

Twist Drill

Ø 2.0 103.162

•Available in Surgical Stainless Steel and Zirconia;

•Instrumentation sequence of surgical alveolus for Titamax Implant;

•Length: 35mm.

Ø 3.0

Ø 3.15

Ø 3.3

103.164 103.245

103.166 103.247

103.165 103.246

Ø 3.8

Ø 4.3

Ø 5.3

103.167 103.248

103.168 103.249

103.169 103.250

Ø 2.8 103.163 103.244

Page 144: Products Catalog - Neodent 2011

144

CM Contra-Angle Connection

105.075

•For the installation of CM Implants with Surgical Torque Ratchet Driver (104.027);

•With six markings, indicating the position of hex index face;

•The laser markings indicate the implant installation depth, bone level, 1 and 2mm infraosseous and the last marking (3mm) biological space.

•Available in Titanium;•Instrumental for implant position orientation;

•Diameter of the central belt corresponding to the CM Implants diameter;

•Smaller side for use after drill 2.0mm;•Bigger side for use after last drill, before the implant installation.

Parallel Indicators

128.019

128.020

128.021

128.022

128.023

128.024

128.025

WS

2.8/3.5

3.0/3.75

3.3/4.0

3.6/4.3

4.3/5.0

Ø 4.3/5.0

Ø 5.3/6.0

•To capture the implant directly on the pack-age;

•For installation of CM implants with contra-an-gle, or coupled to the Digital Driver (104.028) for manual installation;

•With six markings, indicating the position of hex index face;

•The laser markings indicate the implant instal-lation depth, bone level, 1 and 2mm infraos-seous and the last marking (3mm) biological space.

CM Ratchet Connection

105.073 105.074

Short Long

Page 145: Products Catalog - Neodent 2011

145

Ratchet ConnectionExternal Hex – Ti

Ratchet ConnectionInternal Hex – Ti

105.049

105.030 105.031

105.048105.046105.045

5.0

4.3/5.0 4.3/5.0

5.04.1/4.34.1/4.3

Short Short

Short

Long Long

Long

•For installation of External Hex Ti Im-plants with Surgical Torque Ratchet Driver (104.027).

•For installation of Internal Hex II PLUS Implants with Surgical Torque Ratchet (104.027);

•With six markings, indicating the position of hex index face.

Contra-angle ConnectionInternal Hex – Ti

•To capture the implant directly on the package;

•For installation of External Hex Ti Implants and Internal Hex Ti Implants with contra-angle, or coupled to the Digital Driver (104.028) for manual installation;

•With tweezers to increase the security in transport and implant installation.

•To capture the implant directly on the package;

•For installation of Internal Hex II PLUS Implants with contra-angle, or coupled to the Digital Driver (104.028) for manual installation;

•With tweezers to increase the security in transport and implant installation.

105.068

4.3/5.0

Contra-angle ConnectionExternal Hex – Ti

105.047 105.050

4.1/4.3 5.0

Page 146: Products Catalog - Neodent 2011

146

128.015

•Available in Titanium;•For CM prosthetic components selection;•Markings corresponding to the transmucosal height.

1.5

3.55.5

2.5

6.5

4.5

0.8

CM Height Measurer

Drill Extension

•Available in surgical stainless steel;•With screw for drill fixation;•Fixed screw to the drill extension;•For tighten and unleash the screw, it is necessary only around half turn of Hex Driver 1.2 (104.007).

103.091

Titanium Tweezers

•For implants manipulation;•New system of tweezers, that avoids the deviation of the active tip;

•Scale in milimeters, for conference during the procedures;

•Implant self-locking. 129.001

Page 147: Products Catalog - Neodent 2011

147

Hex Connection for Contra-angle

•Available in surgical stainless steel;•Adaptation of hex mounters;•For implant insertion, using motor and contra-angle;•Silicone ring for best fixing and mounter transport.

105.002

Hex Connection for Ratchet (Ratchet Driver Connection)

•Available in surgical stainless steel;•Adaptation of hex mounters;•Fit in squared ratchets;•Silicone ring for best fixing and mounter transport.

105.018105.001

Long Mount

•Available in Titanium;•Requires Hex Connections 105.002 in motor use and 105.001 for Ratchet;

•Use Hex Driver 1.2mm for handling (104.007);•Long mounters 3.3 and 3.5 indicated for substitute the implant mount in cases of reduced interproximal space (mesio-distal).

113.014

Ø3.3 mm

Depth Probe

•Available in Titanium;•For probing preparation and depth analysis;

•Scale in milimeters for conferences during procedure.

129.004129.004

Page 148: Products Catalog - Neodent 2011

148

Digital Driver for Contra-angle Connections

•Available in surgical stainless steel;•Connected to the Contra-angle Connections Ti and II Plus, it becomes a manual driver for the implant installation.

104.028

Hex Digital Driver 0.9mm

•Available in surgical stainless steel;•With divergent hex for best fixing and screw transport;

•Handling of Cover Screws in Implants 3.3, 3.5, 3.75, 4.0, 4.3 and Healing 3.3 height 2mm.

-Short: 20 mm; -Medium: 25 mm; -Long: 38 mm.

104.040104.041104.039

Medium LongShort

Hex Digital Driver 1.2mm

•Available in surgical stainless steel;•With divergent hex for best fixing and screw transport;

•Handling of Mounters in Implants and Cover Screws.

-Short: 20mm; -Medium: 25mm; -Long: 38mm.

104.010104.012104.007

Medium LongShort

Page 149: Products Catalog - Neodent 2011

149

Surgical Torque Ratchet Driver

• Available in surgical stainless steel;• Extremely secure (a variation of less than 5%);• Fitting for square connections;• Collapsible ratchet, that allows the correct cleaning of set.

104.027

Use Instructions

The Surgical Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.

The Neodent Surgical Torque Ratchet Driver has pre-calibrated torques: 45, 60 and 80 N.cm.

The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.

•CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.

• Available in surgical stainless steel;• Extremely secure (a variation of less than 5%);• Fitting for square connections;• Collapsible ratchet, that allows the correct cleaning of set.

For this, only apply the force on the ratchet stem, 1 until it reaches the value set in lateral graduation 2 , which corresponds to the desired torque.

Page 150: Products Catalog - Neodent 2011

150

110.213

105.065

105.041

105.005

105.006

105.007

105.008

105.009

105.044

105.071

128.015

104.005

104.016

104.026

Prosthetic Kit Case

Torque Connection 0.9

Short Torque Connection 1.2

Torque Connection 1.2

Torque Connection 1.6

Slot Torque Connection

Square Torque Connection

Prosthetic Abutment Driver

Short Prosthetic Abutment Driver

Long Torque Connection 1.2

CM Height Measurer

Digital Driver for Torque Connections

Transfer Driver

Prosthetic Torque Ratchet Driver

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Co

mp

lete

Basi

c

150

* illustrative image.

Page 151: Products Catalog - Neodent 2011

151

•Surgical stainless steel;•Extremely secure (variation less than 5%);•Fitting for square connections;•Collapsible ratchet, that allows the correct cleaning of set.

Prosthetic Torque Ratchet Driver

104.026

Use Instructions

The Prosthetic Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.

The Neodent Prosthetic Torque Ratchet has pre-calibrated torques: 10,15,20,32 and 45 N.cm;

The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.

For this, only apply the force on the ratchet stem, 1 until it reaches the value set in lateral graduation 2 , which corresponds to the desired torque.

•CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.

Prosthetic Adaption Driver

•Used to fix the analogues and machine the prosthetic components.

104.036

Page 152: Products Catalog - Neodent 2011

152

Drivers and Connections for Torque

•Available in Surgical Stainless Steel;•Observe corresponding connection to the prosthetic component screw;

•To torque control, the connections must be adapted to the Prosthetic Torque Ratchet Driver (104.026);

•To connections manual torque, must be adapted to the Digital Driver (104.007);

105.009

SquareSlot 1.61.20.9

105.065 105.005 105.006 105.007 105.008 104.005105.041 105.042 105.044

1.6short

1.2short Prosthetic Prosthetic Digital

105.071

1.2long

•Available in Surgical Stainless Steel;•Indicated for Conical Transfer (used in closed tray transfer).

Transfer Driver

104.016

•Available in Surgical Stainless Steel;•Length: -Short: 2 cm; -Medium: 2,6 cm; -Long: 3,8 cm.•Observe screw indications.

Digital Driver 0.9mm Digital Driver 1.2mm

104.039 104.007

Short ShortMedium Medium Long Long

104.041 104.012104.040 104.010

•Available in Surgical Stainless Steel;•Length: -Short: 2 cm; -Medium: 2,6 cm; -Long: 3,8 cm.•Observe screw indications.

105.065

•Observe corresponding connection to the

•To torque control, the connections must be adapted to the Prosthetic Torque Ratchet

•To connections manual torque, must be

Page 153: Products Catalog - Neodent 2011

153

110.223

114.191

114.192 114.193

114.194

114.195

114.196

114.197

114.198

114.199

114.200

114.201

114.202

114.203

114.204

114.205

114.206

114.207

114.208

114.209

114.226

114.227

114.228

114.210

114.211

114.212

114.213

114.214

114.215

114.216

114.217

114.218

114.219

114.220

114.221

114.222

114.223

114.224

114.230

114.231

114.232

114.233

104.007

114.335

114.336

114.337

CM Post 4.5x4x5.5 Prosthetic Selection

CM Post 4.5x4x6.5 Prosthetic Selection

CM Post 4.5x6x0.8 Prosthetic Selection

CM Post 4.5x6x1.5 Prosthetic Selection

CM Post 4.5x6x2.5 Prosthetic Selection

CM Post 4.5x6x3.5 Prosthetic Selection

CM Post 4.5x6x4.5 Prosthetic Selection

CM Post 4.5x6x5.5 Prosthetic Selection

CM Post 4.5x6x6.5 Prosthetic Selection

CM Angled Post 3.3x6x1.5 17º Prosthetic Selection

CM Angled Post 3.3x6x2.5 17º Prosthetic Selection

CM Angled Post 3.3x6x3.5 17º Prosthetic Selection

CM Angled Post 3.3x6x1.5 30º Prosthetic Selection

CM Angled Post 3.3x6x2.5 30º Prosthetic Selection

CM Angled Post 3.3x6x3.5 30º Prosthetic Selection

WS Post 4.5x6x0.8 Prosthetic Selection

WS Post 4.5x6x1.5 Prosthetic Selection

WS Post 4.5x6x2.5 Prosthetic Selection

WS Post 4.5x6x3.5 Prosthetic Selection

Short Digital Driver 1.2

CM Anatomical Post Lateral 1.5 Prosthetic Selection

CM Anatomical Post Lateral 2.5 Prosthetic Selection

CM Anatomical Post Lateral 3.5 Prosthetic Selection

CM Prosthetic Selection Kit Case

CM Post 3.3x4x0.8 Prosthetic Selection

CM Post 3.3x4x1.5 Prosthetic Selection

CM Post 3.3x4x2.5 Prosthetic Selection

CM Post 3.3x4x3.5 Prosthetic Selection

CM Post 3.3x4x4.5 Prosthetic Selection

CM Post 3.3x4x5.5 Prosthetic Selection

CM Post 3.3x4x6.5 Prosthetic Selection

CM Post 3.3x6x0.8 Prosthetic Selection

CM Post 3.3x6x1.5 Prosthetic Selection

CM Post 3.3x6x2.5 Prosthetic Selection

CM Post 3.3x6x3.5 Prosthetic Selection

CM Post 3.3x6x4.5 Prosthetic Selection

CM Post 3.3x6x5.5 Prosthetic Selection

CM Post 3.3x6x6.5 Prosthetic Selection

CM Post 4.5x4x0.8 Prosthetic Selection

CM Post 4.5x4x1.5 Prosthetic Selection

CM Post 4.5x4x2.5 Prosthetic Selection

CM Post 4.5x4x3.5 Prosthetic Selection

CM Post 4.5x4x4.5 Prosthetic Selection

CM Anatomical Post Height 1.5 Prosthetic Selection

CM Anatomical Post Height 2.5 Prosthetic Selection

CM Anatomical Post Height 3.5 Prosthetic Selection

Optional

153

110.223

114.191

114.192 114.193

114.194

114.195

114.196

114.197

114.198

114.199

114.200

114.201

114.210

114.211

114.212

114.213

114.214

114.215

114.216

114.217

CM Post 4.5x4x5.5 Prosthetic Selection

CM Post 4.5x4x6.5 Prosthetic Selection

CM Post 4.5x6x0.8 Prosthetic Selection

CM Post 4.5x6x1.5 Prosthetic Selection

CM Post 4.5x6x2.5 Prosthetic Selection

CM Post 4.5x6x3.5 Prosthetic Selection

CM Post 4.5x6x4.5 Prosthetic Selection

CM Prosthetic Selection Kit Case

CM Post 3.3x4x0.8 Prosthetic Selection

CM Post 3.3x4x1.5 Prosthetic Selection

CM Post 3.3x4x2.5 Prosthetic Selection

CM Post 3.3x4x3.5 Prosthetic Selection

CM Post 3.3x4x4.5 Prosthetic Selection

CM Post 3.3x4x5.5 Prosthetic Selection

CM Post 3.3x4x6.5 Prosthetic Selection

CM Post 3.3x6x0.8 Prosthetic Selection

CM Post 3.3x6x1.5 Prosthetic Selection

CM Post 3.3x6x2.5 Prosthetic Selection

* illustrative image.

Page 154: Products Catalog - Neodent 2011

154

Page 155: Products Catalog - Neodent 2011

155

Surgical Instruments

Page 156: Products Catalog - Neodent 2011

156

Trephine Burs

103.051 103.026 103.087 103.027 103.028 103.029

Ø3.3 mm Ø 4.1 mm Ø 4.3 mm Ø 5.0 mm Ø 8.0 mm Ø10.0 mm

•Available in Surgical Stainless Steel;

•Osseous cylinder collect;•Implants removal.

Bone Profile Drill

Ø3.3 mm Ø 4.1 mm

External Hex Internal Hex

Ø 4.3 mm Ø 5.0 mm Ø 4.3 mm Ø 5.0 mm

•Available in Surgical Stainless Steel;•Used in the second surgical phase;•Adapt the bone around implant platform, preparing the emergency profile compatible with the prosthetic component profile;

•Each drill has a guide with specific diameter.

103.039 103.030 103.085 103.031 103.102 103.103

Angle Measurer

•Available in Titanium;•Angulations: 17° and 30°;•For selection and angulation planning of prosthetic component during the surgical procedure;

•Use indication: after Twist Drill 2.0.

128.017

170

128.018

300

Flags

128.008 128.007

9 mm 12 mm

128.003

7 mm

•Available in Surgical Stainless Steel;•Adaptive to mirrors handle;•Indicated for surgical/prosthetic planning.

AlvimRadiographic Positioner

129.013 129.014129.009

•Available in Titanium;•Used to check flapless osteotomy depth;•It is suggested make the periapical radiography for evaluation.

Ø 3.5 mm Ø 4.3 mm Ø 5.0 mm

0.35mm

16

11.5

13

10

8

Page 157: Products Catalog - Neodent 2011

157

1.8 mm

1.8 mm

2.5 mm

2.5 mm

3.0 mm

3.0 mm

3.5 mm

3.5 mm

4.0 mm 4.5 mm

•Available in Surgical Stainless Steel;•Concave cutting tip for atraumatic elevation of maxillary sinus floor;•Used in the preparing of surgical alveolus for implants installation in posterior maxillary area whith less osseous height;•Markings from 7 to 17mm.

•Available in Surgical Stainless Steel;•Convex tip;•Used when thickness bone is insufficient, requiring compression and prior bone expansion to the implant placement;

•Markings from 7 to 17mm.

110.154

110.160

110.155

110.161

110.156

110.162

110.157

110.163

110.158 110.159

Concave Osteotomes

Spreading Osteotomes

Osteotomes Kit Case

• Available in polymer;• Autoclavable;• Osteotomes sold separately.

110.180

4.5 mm

110.159

17 mm

13 mm

9 mm

15 mm

11 mm

7 mm

17 mm

13 mm

9 mm

15 mm

11 mm

7 mm

Page 158: Products Catalog - Neodent 2011

158

Surgical Mallet

Long Sinus Curette

126.001

• Available in Surgical Stainless Steel;• Used for detachment of sinusal membrane.

126.008

1

126.009

3

126.010

4

126.011

5

126.012

7

•Available in Surgical Stainless Steel;•Active tip in polymer;•Used in Concave and Spreading Osteotomes; •Weight: 130g.

Page 159: Products Catalog - Neodent 2011

159

Disposable Bone Scraper

•Used to remove autogenous bone;•Single use;•Supplied sterile.

127.023

127.016

Straight

127.017

Positive

127.018

Negative

127.019

Blade

Metal Bone Scraper

•Used to remove autogenous bone applied in reconstructive surgery;

•Includes a blade coated with Titanium Nitride;

•Silicone handle;•Autoclavable.

Disposable Bone Collector

•Available in polymer;•Used to collect autogenous bone;•Single use;•Adaptive to vacuum pump;•Two disposable sieves included;•Use the second tip to saliva suction (beware of contamination).

107.003

107.008

Page 160: Products Catalog - Neodent 2011

160

Surgical Labial Retractor

124.001

Columbia Retractor

•Available in Surgical Stainless Steel;•Rounded corners to minimize the surgical trauma.

•Available in Surgical Stainless Steel;•Rounded corners to minimize the surgical trauma.

124.003

Scalpel Handle

•Available in Surgical Stainless Steel;•For use of conventional scalpel blade;•Blade not included.

129.008

Blade and Handle Bivers

•Handle and blade in surgical stainless steel;

•Atraumatic exodontics to implants installation;

•Similar with a periostomal;•Blades supplied individually.

129.002

129.005

•Available in Surgical Stainless Steel;

Page 161: Products Catalog - Neodent 2011

161

Complement Case

•Available in autoclavable polymer;•Used to organize the drills and auxiliar connections.

110.233

Test

Bone Mill

•Available in Surgical Stainless Steel;•Bone volume gain;•The blade has 3 years of warranty against rust;•With lever for better facility during utilization;•Bone mill pestle with slots to optimize the bone block locking during use;•Avoid bone handling originated in tissue bank.

Bovine bone block withvolume = 1,76 cm3

Volume gain was approximately of 7 times.

Amplified particles.

127.011

Page 162: Products Catalog - Neodent 2011

162

1

2

3

6

7

4

5

Advanced design with simple and intuitive panel. Membrane type keys, free of indentations to facilitate the asepsis.

The Neosurg XT Plus is small, light and can be easily transported anywhere. It is a product ideal for anyone who tends to more than one surgery and wishes to have just one surgical motor.

As well as electronic calibration, the motor has a torque ratchet to guarantee yet more precision of the micro motor and contra-angle. The calibration is executed directly by the professional, without the need for maintenance from the manufacturer.

It´s not necessary to autoclave, the hose system is sterilisation only.

Allows perfect adaption of the irrigation handle, offering resistance and security. Can be sterilised.

Use the magnetic induction system, which does not produce noises nor vibrations. High Precision of the torque and variation of speeds.

Rigid body of the micro motor for no risk breaking. Doesn´t lose brightness with time of use, unlike the LED.

Internal and external irrigation system. Head with a reduced size and ergonomically compact body. Better visibility, access and mobility within the oral cavity.

All adjustments of the irrigation system, programs and speeds can be triggered by the pedal, leaving the hands free for surgical procedure. It was developed to avoid the accidental activation of micro motor system (progressive acceleration).

162

The Neosurg XT Plus is small, light and can be easily transported anywhere. It is a product ideal for anyone who tends to more than one surgery and

system, programs and speeds can be triggered by the pedal, leaving the hands free for surgical procedure. It was developed to avoid the accidental activation of micro motor system

CONTROL PANEL WITH EASIER INTERFACE

Con

trol

Uni

t M

icro

Mot

or a

nd C

ontr

a-an

gle

MECHANICAL CALIBRATION SYSTEM

PERISTALTIC PUMP CONNECTED TO THE MOTOR

IRRIGATION SYSTEM WITH METAL CONNECTORS INTELLIGENT CONTROL PEDAL

PORTABLE

MICRO MOTOR REINFORCED WITH TITANIUM COATING

OPTICAL FIBER (VERSION WITH LIGHT)

CONTRA- ANGLE PUSH BOTTOM

Surgical Motor

Contra-angle

Calibration System

With Light

Electronic and Mechanical

Optical Non-optical

Without Light

Electronic and Mechanical

Page 163: Products Catalog - Neodent 2011

163163

2 MECHANICAL CALIBRATION

5

67

4

3

1

ILLUMINATION

Page 164: Products Catalog - Neodent 2011

164

AFFILIATES

Bauru Al. Dr. Octávio Pinheiro Brizolla, 7-46 17.012-059 - Bauru - SP - Brasil Phone: +55 14 3201-3500

Belo Horizonte R. Grão Pará, 554 30.150-341 - Belo Horizonte - MG - Brasil Phone: +55 31 3071-8700

Brasília SH/SUL, QD. 06 CONJ “A” BL. “F” Loja 20 70.316-901 - Brasília - DF - Brasil Phone: +55 61 3298-3200

Curitiba Av. Visconde de Guarapuava, 3832 80.250-220 - Curitiba - PR - Brasil Phone: +55 41 2169-1000

Goiânia R. T-55, 199 - Sl. 4 a 6 74.150-320 - Goiânia - GO - Brasil Phone: +55 62 3878-7700

Londrina R. Senador Souza Naves, 1510 86.010-160 - Londrina - PR - Brasil Phone: +55 43 3306-2000 Porto Alegre R. Félix da Cunha, 836 - Cj. 202 90.570-000 - Porto Alegre - RS - Brasil Phone: +55 51 3272-7400

Recife R. Francisco Alves, 325 - Sl. 401 50.070-490 - Recife - PE - Brasil Phone: +55 81 3202-6900

Rio de JaneiroRua Bento Lisboa, 120 - Lj. “E” Bl. 01 22.221-011 - Rio de Janeiro - RJ - BrasilPhone: +55 21 3622-8900

São Paulo R. Francisco Leitão, 469 - Sl. 1809 05.414-020 - São Paulo - SP - Brasil Phone: +55 11 3728-2700

VitóriaRua Cassiano Antonio Moraes, 100 Loja 0229.050-525 - Enseada do Suá - Vitória - ESPhone: +55 27 3203-5300

INTERNATIONAL AFFILIATES

Portugal Av. Defensores de Chaves, 15 - 3º D 10.00-109 Lisboa - Portugal Phone: +351 21 013 4400

USAJGC North America Corporation3785 NW82 - Avenue Suite 21133166 - Doral, Florida, USAPhone: +305 436 1818

PONTOS DE DISTRIBUIÇÃO NEODENT

FortalezaRua Pedro Borges, nº. 20, sala nº. 808Fortaleza – CE CEP: 60.055-900 UberlândiaAv. Cesário Alvim, 818, sala nº. 504Uberlândia-MGCEP: 38.400-098 Ribeirão PretoRua Rui Barbosa, nº 1145, sala 63, 6º andarRibeirão Preto – SPCEP: 14.015-120

DISTRIBUTORS NEODENT

Campo Grande – MS Alphadent Implantes e Instrumentais R. Padre João Cripa, 2371 – Bairro: Vila Alta CEP: 79.010-180 Phone: 0800 600 5993 / (67) 3027-5993

Cuiabá – MTAlphadent Implantes e Instrumentais Rua das Orquídeas, 337Bairro: Jardim CuiabáCEP: 78.043-148Phone: 0800 601 5993 / (65) 3027-5993 Florianópolis – SC Implantológica - Revenda Neodent R. Felipe Schmidt, 649 - Sala 1401 – CentroCEP: 88.010-001Phone: 0800 600 6069(48) 3225-6069 / (48) 3028-7169

Manaus – AM A R. Rodriguez Av. Joaquim Nabuco, 2235 CEP: 69.020-030Phone: (92) 2121-7700

Salvador - BA Implante Way Produtos Médicos - Odontológicos Ltda Rua Senador Theotônio Vilela, 190 Ed. Convention Center , SL 506 - Pq Bela VistaCEP: 40.279-435 Phone: 0800 284 5378 / Fax: (71) 3351-5378 Palmas – TOProdentis Produtos OdontológicosCentro Comercial Água VivaQuadra 104 Norte, Rua NE 01, nº 27 - Sala 03CEP: 77.006-016Phone: 0800 646 1012 / (63) 3224-1010

Belém – PACIRUBELCirúrgica Belém Com. & Representações LtdaTravessa 9 de Janeiro, 1295CEP: 66.060-370 Phone: (91) 3204 2729 / 8802 [email protected]

INTERNATIONAL DISTRIBUTORS

ArgentinaDis-Den 1. Santa Fé 3153 2000 Rosario Phone: +54 341 438 4433 2. Fernando Ochoa, 645 1852 Burzaco, Buenos [email protected]

Bolivia Odonto Market Calle Ichilo, 205 – Zona B Palermo, Santa Cruz Phone: +591 3 339 4089 / +591 3 339 [email protected]

Chile Comercial Express Dent Av. Presidente Errazuriz, 4125 Las Condes – Santiago - Chile Phone: +56 2 233 6690 / +56 2 263 3720 [email protected]

Colombia Pluss Dent Calle 23 Norte, nº 5 –BN – 69 - Cali Phone: +57 2 660 0050 [email protected]

Equator Odontotec Portete, E 1380 Iñaquito - Quito Phone: +593 2 245 4575 [email protected]

Spain Perdental Calle Cristóbal De Boleda, 14 25006 - Lleida Phone: +34 9021 17077 / 9021 17120 [email protected]

ItalyBio-Sfera Via C. Pavese, 50 Peschiera Borromeo – Mi Phone: +39 349 224 1190 [email protected]

Lebanon Implanet Dekwaneh Slaf Main Road Yervan Bldg - Beirut Phone: +961 169 2123 [email protected]

Paraguay Dent. Par Shopping Yguazú Av San Blás 765 - Ciudad del EstePhone: +595 61 510 829/ 30 [email protected]: sac.dentpar

Peru Dent Import Av. Teodóro Cárdenas 163, OFC. 1 - Lima Phone: +51 1 411 0600 Anx.204+51 1 265 0759 / +51 1 98911 7300 [email protected] Dominican Republic Idemefa Calle Pedro A Bobea, Esq. Primera, Bella Vista Santo Domingo Phone: +1 809 535 2585 [email protected]

Thailand Integrated Dental Equipment54 Soi Phanit Anan, Sukumvit 71 RoadKlongton Nua, Wattana – BangkokPhone: 66 2713 3355 / 668 9798 [email protected]

Venezuela Dental El Bosque Av. Universitaria Resd Diamante Local P.B. Valle Abajo - Caracas Phone: +58 212 6614280 / 6617790 / 6619497 [email protected]

www.neodent.com.br