products catalog of company members - kea.kr · products catalog of company members ... 7...

55
113, Jungdae-ro, Songpa-gu, Seoul, Korea Main number: 82-2-2223-3600 Products Catalog of Company Members National happiness world being opened by electricity! National happiness world being opened by electricity! Products Catalog of Company Members

Upload: duongkhue

Post on 28-Jul-2018

235 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

113, Jungdae-ro, Songpa-gu, Seoul, Korea Main number: 82-2-2223-3600

Products Catalog of Company Members

National happiness world being opened by electricity!

National happiness w

orld being opened by electricity!Products Catalog of Company Members

Page 2: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

National happiness world being opened by electricity!

Note that this catalog was created to promote the products of company members of Korea Electric Association (KEA), and KEA is not the party to sell the products, thus not taking any responsibilities for products, trade information, and transactions; instead, buyers and sellers are fully responsible for all the business transactions. The details of this notice can be found on the KEA website (www.kea.kr), so make sure to read thoroughly.

Products Catalog

Published date June 30, 2016

Publisher Korea Electric Association

Address 113, Jungdae-ro, Songpa-gu, Seoul, Korea l www.kea.kr

Design by Taeshin Media

WiWiWiWiririrringnggnng anandd Raceeeewwwawwaw y SuSupppplilililieeses

CaC blb eseseses

SwwS ititchchgeeg arararra , ,DiDiD ststriribub tiononnnnnn PPPPanannnanelelelleeleleleel anand d CoCoC ntntrororolll l l PaPaPaPaneneneeeell

Transformer,UPS

Utilization Equipment and others

SSuSuSuuppervisory CoContntrorol l Syystemm

New Renewable Energy

Relay, Protective Equipment, Protective Devices and Parts

Meter,,, MMMMeae susuuuriririringngngng IInInII ststrurumemmentnt aaandndnn PParra tsts

Switch,Breaker

Plant Equipment and Instrument

Rectifier, Charger, Inverter

CONTENTS

Supervisory Control SystemSupervisory Control SystemSupervisory Control System111 022022

Switch, BreakerSwitch, BreakerSwitch, Breaker22222 090909

Relay, Protective Equipment, Protective Devices and PartsRelay, Protective Equipment, Protective Devices and PartsRelay, Protective Equipment, Protective Devices and PartsRelay, Protective Equipment, Protective Devices and Parts333333333 188188

e er, easuring ns rumen an ar sMeter, Measuring Instrument and PartsMMeter, MMeasuriing IInstrument andd PPartsMMeter, MMeasuriing IInstrument andd PParts44444 3434

Plant E ui ment and Instrument Plant E ui ment and Instrument Plant Equipment and Instrument Plant Equipment and Instrument55555 4141

r ng an aceway SSupp es Wiring and Raceway Supplies WWWWiiiriiing andd RRaceway SSSSupplliiies WWWWiiiriiing andd RRaceway SSSSupplliiies66666 5050

Switchgear, Distribution Panel and Control Panel Switchgear, Distribution Panel and Control Panel Switchgear, Distribution Panel and Control Panel Switchgear, Distribution Panel and Control Panel777777 63366366336633

Transformer, UPS Transformer, UPS Transformer, UPS88888 6868

New Renewable Energy New Renewable Energy New Renewable Energy New Renewable Energy 99999 7777

Cables Cables Cables10011111100111100 79797979

ect er, C arger, nverter Rectifier, Charger, Inverter RRectiiffiier, CChharger, IInverter RRectiiffiier, CChharger, IInverter1111111111 88686688668866

tilization Equipment and others Utilization Equipment and others Utilization Equipment and others Utilization Equipment and others1111112211122 990990990

Manufacture Company Introduction Manufacture Company Introduction Manufacture Company Introduction1331111113311133 949494

Page 3: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

3

Supervisory Control System

AE SYSTEM Purchase Inquiry 96 p

AEMS is to monitor and evaluate structure health by using Acoustic Emission Testing method which acquire transient elastic wavescaused by failure, leak, crack anddeformation within a material

If there are faults in object, elastic wave soccurs in the smallest deformation or microcrack growth of material. AEMS is possibleto detect or forecast the defect or fault of material and structure by analyzing AE features.

Applications : Large pressure vessels, tubing, high-pressure gas storage vessel, cylindrical liquid storage tanks etc.

Model Description

AE Sensor 20kHz ~ 1.2MHz

Pre-amplifier signal → signal first amplication (0 / 20 / 40 / 60dB)

Main-amplifierfirst amplication signal → second amplication signal particular signal Filter, RMS output

AE-300 Signal process S / W

Supervisory Control SystemSupervisory Control SystemSupervisory Control System

System consist of 4 part- Sensing Device, Signal conditioner, DAS, HMI Leak signals are inputted from compound sensor for AE and vibration Pre Amp 1st amplify several uV signal to mV signal Main Amp perform 2nd amplifier , Filter, and RMS Output Amplified signal perform High signal processing using High speed Data Acquisition System

AE features extraction , fault signal analysis, Source location are performed in Software

Signal Level (Caution and Alarm signal) provide incase of plant facility

Model Description

Sensor AE : 50k ~ 200kHz / Accelerometer : ~ 20kHz

Wave-guide Sensor Jig, Holder

Pre-amplifier• Input power : 24VDC, 4mA• Gain : 20 / 40dB (Selectable)

Main-amplifier• Pre-Amp Input power : 28VDC, 200mA• Gain : 0 / 20 / 40dB (Selectable)

Software•Position estimate algorithm•3D Boiler modeling•Detection S / W

BTLD SYSTEM Purchase Inquiry 96 p

Page 4: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

4 5

Supervisory Control System

Supervisory Control System

WCMS (SCADA) SYSTEM Purchase Inquiry 96 p

Monitoring of vibration and rotating speed for main shaft, gear box, generator, and tower

Monitoring integrated with wind turbine SCADA system, vibration, RPM, Oil contamination, thermal camera and fire

watching

Customers : Namjeju Thermal Power Plant Wind Power Team, Doosan Heavy Industry

Model Description

Input resistace More than 100kΩ

Stability ±μV /

Frequency 0 ~ 20kHz

Inputsignal type 100kHz

CurrentIEPE input : 4 ~ 6mA, constant current input : 24V

exsaver (Automatic Receptacle Control System)

Purchase Inquiry 99 p

The ‘exsaver’ is a brand new system of ‘power auto-control’, coupled with the pre wiring-tubing module (excelline), for over-all

control of electricity use-patterns such as: usage metering, usage

set, usage target, watch use-log, scheduled control, loss by no-

load, (standby power), etc.

Model Description

RTU

• Local manual recovery device.• It restores the power by inputting address of each unit, whose no-load power (standby power) is blocked automatically and shows electric use by each circuit.

LCU

• Unit control repeater equipment• LCU composes a driver part with several channels, sensing and instrumentation part and control part. Main CPU controls status (information) of terminal load, connected to each channel

CMG

• Communication device for single control of panel board.

• Communication with different phase, Supporting repeating function, expanding communication service range, Securing communication reliability, Supporting ethernet networking.

RTU LCU

exsaver working drawingCMG

ESS(Energy Storage System)

Instrument to supply high quality power and increase power utilization efficiency and reserve ratio by saving power in the middle

of the night during which power usage is low and supplying power

during the time in which power usage is high.

Characteristics

• Compensate the discontinuous generation characteristics of new renewable energy such as solar energy and wind power, etc. (New renewable power stabilization) and REC improvement of wind power generation.

• Manage power usage and save electricity bill by charging/discharging in response to industrial/building power demand (normally use for power demand management; in case of unexpected blackout as uninterrupted emergency power supply)

• Keep the power system stabilized in response to frequency variation of Korea Electric Power Corporation’s power system (frequency regulation).

• Supply uninterrupted emergency power in case of industrial/building emergency and uninterrupted battery system coupled with diesel generators.

Purchase Inquiry 99 p

Distribution feeder protection IED Purchase Inquiry 100 p

This product is Intelligent Electronic Device (IED) which is designed to carry out vairous functions such as protection, control,

measurement, interlock functions for 25.8kV GIS in digital substation

and the IED uses for protecting main transformer’secondary Main

feeder / Distribution line, Sh.C, S.Tr / Bus Tie, Bus section / PT bay.

Features

• Various proteion function (50 / 51, 50N / 51N, 79, 59, 27, 59GA,

59GT, UBOC)

• Various measurement function (current, voltage, apparent power,

Active / Reactive power, Power factor, Frequency)

•Interlock logic function based on PLC

•Monitoring and control function •Self-diagnosis function

•Event and Fault record function •IEC61850 Communication protocol

Model YSDPI-9800

Control power DC 125V±20%

Power consumption

Permanent 30W or less, Operational 50W or less

RatedVoltage 110 / √3V, 190 / √3V, 190 / 3V

Current AC 5A

Input

Voltage / Current 4CT, 4PT or 8PT

Digital (DI) 28ea

Analog (AI) 5ea (4 ~ 20mA×5ea)

OutputControl 14ea (‘a’×14ea)

Alarm 2ea (‘c’×2ea)

CommunicationFront USB port ( for PC HMI)

Rear Optic port (ST type) 2ea (IEC61850, Spare)

Dimension 304×275×259 (mm)

Page 5: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

6 7

Supervisory Control System

Supervisory Control System

GMDS(Generator Monitoring & Diagnosis System)

YPP GMDS is an integrated diagnosis system of generators. It allows for the prediction and monitoring of the operation

processes of generators in an integrated manner.

The system assists users for offensive responses against variety

of troubles that may take place during the operation processes of

generators through predicting and monitoring a variety of incidents,

including the insulation break of the stator winding, the Layer Short

Circuit of a rotator, and vibration from the stator and rotor.

Features

• Diagnosis of a partial discharge

• Diagnosis of layer short circuit of turning

• Real-time vibration diagnosis

Purchase Inquiry 99 p

ECMS (Electrical Equipment Control & Monitoring System)

Purchase Inquiry 99 p

The electrical protection monitoring control system is founded based on the latest digital protective relays and network technology. It

is an automation system that protects, monitors, and controls the

electrical systems of plants and power generators, minimizing the

impact when systems fail by isolating them promptly, preventing

accidents, and ensuring faster and safer recovery from failures to

maximize the reliability of equipment provided.

The power monitoring and control solution of YPP is rooted in

the unmatched technical capabilities and field experiences we

accumulated from performing successfully in various power plants,

substations, petrochemical plants, semiconductor production

facilities, and steel plants, etc.

Features• High reliability and safety proven through various projects around the world• Optimized protection for power equipment using high performance digital protective relays• High operation efficiency based on the optimized visualization of the power system and protection system• High reliability network operation using optical communication and redundancy supports• Reduction of thee operation cost through thee integrated system for protection, surveillance, and control• Multi-dimensional power facility monitoring systems can be established through integrated operation with the diagnosis system• Less time for recovery thanks to faster and streamlined event and failure analysis• Improvement interoperability by applying IEC61850 Ed.

This is a high-reliablilty supervisory control and data acquisition system for various industrial plant and power equipments.

Clause Description

Functions

Remote data acquisition and control

Display status of live feeder and bus line

Display and edit database

Report excel based data sheet

Display trend diagram for measured data value

Features

Simple operation

Communicate with a great number of IEDs of RTUs (IEC 61850, DNP 3.0)

Support Microsoft Windows 7

Support Microsoft SQL Server

154kV Substation Automation Operating System

Purchase Inquiry 100 p

On-Line GIS PD Diagnostic System

Purchase Inquiry 100 p

On-Line GIS PD Diagnosis System Measures and analyses to diagnose and monitor Partial Discharge of GIS.

The System is consisted of DAU, Local Unit, Main Unit, HMI for providing condition monitoring service.

Item Description

Frequency Range 500 ~ 1500[MHz]

Sensitivity Minimum detection level : –65[dBm]

Power Supply AC 220V, 60Hz

Comm

RS-232 2 Ports

Ethernet10 / 100BASE-TX : 1 Port,10 / 100BASE-FX : 2 Port

Channel 3 or 6 Channel

Synchronization PT, AC220

LED Power, Comminication, Channel Status

LCD 4.3″Graphic LCD (option)

ETC Watchdog & Self-Diagnosis, ETC

MU / LU

Page 6: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

8

Supervisory Control System

PD simulator for testing for GIS Partial Discharge Monitoring System

GIS partial discharge PD simulator (PDPS), Device that tests sentsiivity, performance and failures of the partial discharge

detection system including the sensors to monitor a condition of

gas insulated switchgear (GIS) in power stations and substations,

supports the efficient management of partial discharge diagnostic

system through the function of generating partial discharge sginal

simulation by types (Corona ,Void, Floating, Particle) which is

synchronized with system power source, and analyzing the data.

Category Specification

Frequency 500 ~ 1,500[MHz]

Signal Power-10 ~ -40[dBm] ( (In case of using a fixed

attenuator : - 40 ~ -70[dBm])

Power DC 12V / 3.5A

Battery 11.1[V], 10,400[mAh]

Synchronization AV 220V

CommRS-232 2 port

Ethernet 10 / 100BASE-TX : 1 port

Channel 3 channels, N-Type Connector

LCD 7″TFT-LCD, Touch Screen

Size 242 (W)× (H)×64 (D) [mm]

Purchase Inquiry 100 p

PDPS

Page 7: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

10 11

디지털보호계전기 및 배전, 제어반

디지털보호계전기 및 배전, 제어반

10 11

Switch, Breaker

Switch, Breaker

ATS (Auto Transfer Switch)

Purchase Inquiry 97 p

ATS provides a stable power and a user-centered safety as well as the reliability and safety based on the quality and intensive

technology that are recognized even by UL.

TypeRated Current

(A)Rated Voltage

(V)Poles

Connection Type

W 100, 200, 400 AC600 2, 3, 4 Front / Back

WP 100, 200, 400 AC600 2, 3, 4 Front

WN100, 200, 400, 600, 800, 1000, 1200, 1600, 2000, 2500, 3000

AC600 2, 3, 4 Front / Back

HS 100, 200 AC200 2 Front

ACB is a circuit breaker that passed new IEC stnadard and KS standard development tests. It is a premium circuit breaker that is

convenient to use with a design that enables a short breaking time

and maximum safety and protection functions.

Frame (AF) 2000 4000

Rated Current (In)200, 400, 630, 800, 1000, 1250, 1600, 2000

2500, 3200, 4000

Rated Operational Voltage (V)

690 690

Rated Short Time withstand Current (kA) / 1s

50 65

ACB (Air Circuit Breaker)

Purchase Inquiry 97 p

VITZROTECH’s VCB has improved the interruption performance as well as stability of its products through optimizing vacuum technol-

ogy with enhanced structural design that reflects the years of ex-

pertise in vacuum application techniques.

Rated Voltage (kV)

Breaking Current (kA)

Rated Current (A)

7.2kV 8kA ~ 40kA 400A ~ 3150A

12 / 17kV 20 / 25kA ~ 40kA 630A ~ 3150A

24 / 25.8kV 12.5kA ~ 40kA 630 ~ 3150A

36 / 38kV 31.5 ~ 40kA 1200 ~ 3000A

25.8 / 36kV(outdoor) 25 ~ 40kA 600 ~ 2000A

VCB (Vacuum Circuit Breaker)

Purchase Inquiry 97 p

Wire fuses are used for protecting the service line of low voltage customers. When wire fuse melted down, lineman can easily find

the burned deviant spot on the fuse surface at ground. Features of

wire fuses include,

• Have a excellent breaking capacity compared with catch holder.

• Verified the resistance to UV degradation and surface tracking.

• Good coordination with applied wire.

Type Rated Current Applied Wire

2.6 38A 2.6mm

3.2 50A 3.2mm

22 100A 22

38 150A 38

60 200A 60

100 300A 100

Wire Fuse Purchase Inquiry 97 p

The pole-mounted LBS can be manually operated or motorized for fault isolation, remote control and automation to suit your power

line requirements. The pole-mounted LBS has been fully certified

in accordance with IEC 60694 (1996), IEC 60265 (1998) to meet and

exceed customer’s requirement.

Model Insulation Rated Voltage

KMPGS-6A (6M) SF6 Gas 25.8kV

Pole Mounted Load Breaker Switch (PGS / LBS)

Purchase Inquiry 95 p

Overhead

Pole mounted switches a SF6 gas-insulated 3-phase sectionalizer

with voltage and current sensor. The switch can either be

mechanically operated with a hook stick or automatically operated

with a motor driving mechanism.

Underground

Pad mounted switchgear with SF6 gas insulation is used for multi

branch system of underground distribution line. The switchgear is

also connected to SCADA system via DNP 3.0 protocol. Features of

pad mounted switch include,

• Uses sulphur hexafluoride, SF6 gasl, as the main arc

extinction (puffer) and insulation medium.

• 3-position operation (closed-open-earth) and easy cable earthing.

• With PT for auxiliary control power.

Model Type Usage

AGS-4300 SF6 Gas Insulated Overhead Line

GS-44-D-A-125 SF6 Gas Insulated Underground Line

SF6-Insulated Load Break Switch

Purchase Inquiry 97 p

Overhead Type

Underground Type

Page 8: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

12 13

디지털보호계전기 및 배전, 제어반

디지털보호계전기 및 배전, 제어반

12 13

Switch, Breaker

Switch, Breaker

Environmentally friendly product

Vacuum Interrupter

CB Part : Magnetic Actuator Mechanism

LBS Part : Spring Toggle Mechanism

Intelligent Protection Relay

Manual Open / Close Capability

Solid Pad mount Switchgear Purchase Inquiry 101 p

Environmentally friendly product

Solid Dielectric Application

Free for SF6 gas use

Maintenance free

Rated Voltage 12 kV 25.8 kV

Rated Current 630 A

Impulse withstand Voltage (BIL) 20 kA 12.5 kA

AC Power freq.withstand Voltage

110 kV 125 kV

Impulse withstandVoltage

50 kV 60 kV

Rated Voltage 12 kV 25.8 kV

Rated Current 630 A

Impulse withstand Voltage (BIL) 20 kA 12.5 kA

AC Power freq.withstand Voltage

110 kV 125 kV

Impulse withstandVoltage

50 kV 60 kV

Solid Pad mount Load Break Switch

Purchase Inquiry 101 p

Environmentally friendly product

Vacuum Interrupter

Magnetic Actuator mechanism

Maintenance free

Intelligent Protection Relay

Manual Open / Close Capability

Rated Voltage 15 kV 27 kV 38 kV

Rated Current 630 / 800 A

Impulse withstand Voltage (BIL) 110 kV 150 kV 170 kV

AC Power freq.withstand Voltage

50 kV 60 kV 70 kV

Short time current 16 kA 12.5 kA 16 kA

Making current 40 kA 31.5 kA 40 kA

Solid Recloser

Environmentally friendly product

Vacuum Interrupter

Spring Toggle mechanism

Maintenance free

Intelligent Protection Relay

Manual Open / Close Capability

Rated Voltage 15 kV 25.8 kV 36 kV

Rated Current 630 A

Impulse withstand Voltage (BIL) 125 kV 150 kV 170 kV

AC Power freq.withstand Voltage

50 kV 60 kV 70 kV

Short time current 20 kA12.5 / 16 kA

12.5 kA

Making current 40 kA 32.5 kA 32.5 kA

Load Break Switch

Purchase Inquiry 101 p Purchase Inquiry 101 p

Protect the insulation joint of the pipe from induced surge

Protect the insulation joint of the pipe from inflow of fault current

Interrupt DC currents for anticorrosion system

Item Specification

Size• 255×328×120 (including the terminal length)

Current Carrying Voltage• DC -1 ~ -12V / +1 ~ +12V (Possible to change current level in DC)

Lightning Stroke Current • 70 in application of Class Ⅱ

Fault Current • (60) 30cycle, 3.7 and more

Regular Appliable AC Current

• AC 38A

Explosion Proof / Water Proof • Increased safety / IP 54

DC Decoupling Device Purchase Inquiry 99 p

OMNI EPA-3.7-3

Page 9: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

14 15

디지털보호계전기 및 배전, 제어반

디지털보호계전기 및 배전, 제어반

14 15

Switch, Breaker

Switch, Breaker

Usage : Attached on the primary side of a pole transformer to protect the transformer and to make and break the circuit.

Characteristics

• Excellent compatibility, easy delivery and installation due to being

lightweight, stable function, durable, excellent weatherproof, self-

cleaning features

Type PCOS-125 1PCOS-150

Rated Voltage 25.8 kV 25.8 kV

Maximum Voltage 27.0 kV 27.0 kV

Rated Frequency 60 Hz 60 Hz

Rated Breaking Current

Asymmetrical RMSOver 22.9 Over 22.9

Symmetrical RMS

Impulse Withstand Voltage

Terminal - ground125 kV 125 kV

Terminal - terminal

Applicable Standards ANSI / IEEE Std C37.40.C37.41

Polymer Cut-out Switch Purchase Inquiry 102 p

Require less space than conventional open-air substations

Provide maximum safety for operating personnel with grounded enclosures and all live parts contained

Design comprised of standardized modules, resulting in high quailty production, simple assembly and easy installation

Specifications

Rated Voltage Applicable standards

~ 800KV IEC, ES

Gas Insulated Switchgear Purchase Inquiry 103 p

HG-Series Molded Case Circuit Breaker

Masimized Selectivity and Safety with Various Products Range & Breaking Capacity

Various product Range 30 ~ 800 AF

Rated Insulation Voltage (Ui) 1,000 V

Ics=1,000% Icu

Rated Insulation Voltage

Rated Operational Voltage

Applicable standards

1,000V 690V IEC 60947-2

Purchase Inquiry 103 p

Environmentally friendly product

Improved Safety by double layer case

Compact size and easy installation

Convenient extension by modular structure

High Reliability of breaking

Various compose with LBS, FUSE and CB

Classification SW CB FUSE SW CB FUSE

Rated Voltage 12 25.8

Rated Current 630 200 630 125

Rated Breaking current

- 20 40 -12.5,16

40

Rated Making current

52 32.5 / 41.6

Rated Short-time current

20 12.5 / 16

SF6 Gas Insulated Ring Main Unit (RMU)

Purchase Inquiry 101 p

Solid dielectric Ring Main Unit (RMU)

Purchase Inquiry 101 p

Self Power Relay (ETR20) and Digital Relay

3 Cycels interruption Capability

Spring Charged Mechanism

Manual Open / Close Capability

Item SW / CB SW / CB FUSE

Rated Voltage 17.5 kV 24 kV

Rated Current 630 A

Impulse withstand Voltage (BIL)

110 kV 125 kV

AC Power freq.withstand Voltage

50 kV 50 kV

Breaking Capacity- Short circuit- Making Capability

21 / 21kA54.6 / 54.6kA

16 / 25kA40 / 40kA

Page 10: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

16 17

디지털보호계전기 및 배전, 제어반

디지털보호계전기 및 배전, 제어반

16 17

Switch, Breaker

Switch, Breaker

Medium Voltage Electric Equipment(Ring Main Unit - RMU)

Rated voltage & current : 12 / 17.5 / 24kV 21kA

Rated breaking time : 3s

Rated current : LBS-630A, CB-630A, SW-Fuse-200A

Making & Breaking test level : LBS-E3 / C2 / M1, CB-E2 / C2 / M1

Internal Arc (IAC) performance : 21kA / 1s, AFL

Rated gas (SF6) pressure : 5 Psi G

IEC 62271-200, 100, 102, 103, 105

Purchase Inquiry 104 p

Medium Voltage Circuit Breakers(Vacuum Circuit Breaker - VCB)

Rated breaking time : 3s

Standard operation duty : O-0.3s-CO-3min-CO

Making & Breaking test level : M2, E2 (List3), C2

IEC62271-100 (2008), KERI, KEMA development testing, V-check certification

Model Rated Voltage Rated currentBreaking capacity

VL model 7.2 / 12 / 17.5 / 24 / 25.8kV 400 ~ 2500A 8 ~ 31.5kA

LVB model 7.2 / 12kV 1250 ~ 3150A 31.5kA ~ 40kA

VH model 7.2 / 12 / 17.5 / 24 / 25.8 / 36kV 1200 ~ 4000A 25 ~ 50kA

Purchase Inquiry 104 p

Low Voltage Circuit Breakers(Air Circuit Breaker - ACB)

Rated breaking capacity (Ics=Icu) : 85 / 100 / 150kA @ 500VAC

First to obtain UL 1066 in Asia

IEC60947-1, 2 / KS, KEMA, CE, major eight ship classification, JIS / JEC, GOST, UL 1066

Model Rated current Breaking capacity

AH model 200 ~ 6300A 65 ~ 150kA

AS model 200 ~ 6300A 50 ~ 120kA

Purchase Inquiry 104 pHG-Series Vacuum Circuit Breaker

Masimized Selectivity and Safety with Various Products Range & Breaking Capacity

Various product Range 30 ~ 800 AF

Rated Insulation Voltage (Ui) 1,000 V

Ics = 1,000% Icu

Rated Insulation Voltage

Rated Operational Voltage

Applicable standards

1,000V 690V IEC 62271-100

Purchase Inquiry 103 p

Low Voltage Circuit Breakers(MCCB)

Adjustable rated current

High performance : 150kA (Ics=Icu)

Communication function : modbus

DC Solution available

Model Rated current Breaking capacity

TS100 ~ 1600 15 ~ 1600A 65kA at 480V

MC-6a ~ MC-2100a 6 ~ 2100A -

Purchase Inquiry 104 p

Low Voltage Electric Equipment(Magnetic Contactors)

Common and modularized accessories

Use of direct connectible Thermal Overload Relay (TOR)

Safety cover available

CE, UL, KEMA certification, KR, Lloyd (LR), CCC, NK, BV, ABS, GL, DNV, S-Mark

Model Rated current

MC-6a ~ MC-2100a 6 ~ 2100A

Purchase Inquiry 104 p

Page 11: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

19

Relay, Protective Equipment,

Protective Devices and Parts

CURRENT TRANSFORMER

Voltage Transformers

For Indoor

For Metering & Protection

Small size & light weight design

Insulation Epoxy Vacuum Molding

Max. voltage product structure

1.15kV

Round Type

Winding Type

Window Type

7.2kV

Bus-bar Through Type

Winding Type

12kV

Bus-bar Through Type

Winding Type

25.8kV

Bus-bar Through Type

Winding Type

- Zero Phase Type

- Bushing Type

- Split Type

1.15kV∼7.2kV Standard Type

For Indoor

Single Phase Line to Line Voltage Transformer

Single Phase Line to Earth Voltage Transformer

For Metering & Protection

Insulation Epoxy Vacuum Molding

Max. voltage product structure

1.15kV

Voltage Transformer

Earthed Voltage Transformer

Three Phase Voltage Transformer

Three Phase Earthed Voltage Transformer

3.45kVVoltage Transformer

Earthed Voltage Transformer

7.2kVVoltage Transformer

Earthed Voltage Transformer

12kVVoltage Transformer

Earthed Voltage Transformer

25.8kVVoltage Transformer

Earthed Voltage Transformer

1.15kV∼7.2kVStandard Voltage Transformer

Power Transformer

25.8kV SF6 Gas Earthed Voltage Transformer

Purchase Inquiry 95 pPurchase Inquiry 95 p

Protective Devices and PartsRelay, Protective Equipment, Relay, Protective Equipment,Protective Devices and PartsProtective Devices and Parts

Page 12: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

20 21

Relay, Protective Equipment,

Protective Devices and Parts

Relay, Protective Equipment,

Protective Devices and Parts

Earth Leakage Detector & Ground Relay Purchase Inquiry 95 p

Earth Leakage Detector : This Earth Leakage Detector uses line earth fault fewer than working voltage 600V to do protection when

Operation produces earth fault to ZCT Primary line flowing earth

current do detection through ZCT and is arithmetic type earth leakage

detector that is used to check fault extension breeding alarm.

Ground Relay : This Relay uses 600V or less Electric Circuit Ground Fault by purpose to do Protection Electric demand place

and operating detects flowing earth Current through ZCT at Ground

Fault appearance in ZCT load circuit. So. circuit is Digital Relay that

protect device and electric circuit through interception or alarm

This Digital Relay becomes big help in authoritativeness elevation

because can setting of various operating time and operating current

is easy and records fault information and store

Digital Relay Purchase Inquiry 95 p

K-PAM Series is digital integrated type protection relay with protection, control and monitoring function. according to purposes of protect-

ing, you can choose the line protection relay and distributed power

protection relay, motor protection relay, transformer protection relay

GD Series & GDR Series...

• consist of various type of relay for TL, DL, Generator, transformer,

Motor DS, etc. So. it can be possible to be applied to all parts of

power System

• Correct Measurement & Various Display Functions are realized

• Remote Central Monitoring can be possible based on Fast &

Stable Communication

• Self-Diagnosis & Noise Test make the relay reliability be improved.

• Event History can be saved for looking into all the events, Relay

Operation & Setting Values Changing, etc, occurred on arelay.

• Fault Waveform can be saved for easilt Analysis of a relay

operation, when will be operated by a fault of power System.

• Using Relay & Panel Manufacturing are easy.

Category Separation

K-PAM Series

F3300 / Line protection

DG3300 / Distributed power protection

M3300 / Motor protection

T3300 / Transformer protection

GD Series&

GDR Series

Over Current protection

Long Time Over Current protection

Ground Over Current protection

Over Voltage protection

Capacitor Over Voltage protection

Under Voltage protection

Over Voltage Ground protection

Directional Ground protection

Over Power protection

Under Power protection

Reverse Power protection

Phase Open protection

Ratio Differential protection

Category Separation

Earth Leakage Detecto

10circuit Digital arithmeticRS-232C communication

6, 8, 10, 12, 16circuit Digital arithmetic

8, 16circuit Digital arithmeticRS-485 communication

Static type 1circuit Socket Type

Static type 1circuit Flush Mounted Type

Ground Relay

10circuit Digital Operation type / 232C communication

10circuit Digital arithmeticRS-232C communication

Static type 1circuit Socket Type

Induction Type Protective Relay

This relay which is similar to watt-hour meter in construction apply the theory of induction disk and consists of an electromagnet, a ro-

tary disk, a damping device, an indicating contact switch (ICS) and

an indicating instantaneous trip unit (IIT) when required. when the

current in the relay exceeds a given value, the disk with its torque

begins to rotate overcoming the spiral spring and after specified

time relay, this relay closes a main contact to trip the circuit breaker,

time delay is determined by the setting of the time dial. the indicat-

ing contact switch unit has a coil in series and a contact in parallel

wich the main contact. This unit is purposed to insure the perfect

closing of the trip circuit and protect the main contact.

Product Category Separation

Current Relay

Over Current

Long Time Over Current

Ground Over Current

Voltage Relay

Over Voltage

Capacitor Over Voltage

Under Voltage

Over Voltage Ground

Directional Relay Directional Ground

Power Relay

Over Power

Under Power

Reverse Power

Phase Open Relay -

Differential Relay -

Purchase Inquiry 95 p

Power Transducer

Power transducer is apparatus to trance the electrica value of AC power system voltage, current, Watt, var, power factor,

frequency,etc,to DCvoltage or current in proportion to its respective

value for measuring purposes. This is the most suitable to transmit

the electrical value of AC power system to the digital meter,

recorder analog meter etc, on the remote supervisory panel and

widely use for input signal to computers, auto-control system, etc.

K-MAX MDT300, MDT3000 is digital complexity type transducer

that is possible the concentrated display and it is applicable to

souid ground and ungrounded system.

Product Category Separation

Current Transducer1P2W / 3P3W / 3P4W

Voltage Transducer

Watt Transducer

1P2W1P3W3P3W3P4W

Watt-Hour Transducer

Watt & Watt-Hour Transducer

Var Transducer

Var-Hour Transducer

Var & Var-Hour Transducer

Power Factor Transducer

Frequency Transducer -

DC Isolating Transducer -

Digital Integrated type Transducer 1P2W ~ 3P4W

Purchase Inquiry 95 p

Page 13: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

22 23

Relay, Protective Equipment,

Protective Devices and Parts

Relay, Protective Equipment,

Protective Devices and Parts

Categorized into 3-phase, voltage, directional relays; easier fault analysis due to real time storage of maximally 16 fault data up to 128

events.

Item Relay Elements

Over Current (DIPR-OC01) 50 / 51×3, 50N / 51N

Under Voltage (DIPR-OV01) 27×3, 59×3, 64

Directional (DIPR-SG01) 64, 67N, 67G

Digital Power Protective Relay Purchase Inquiry 96 p

Digital Earth Leakage Detector (ELD) Purchase Inquiry 96 p

Digital Ground Fault Relay (GFR) Purchase Inquiry 96 p

An Complete Arithmetic Earth Leakage Detector for being used to protect from leakage faults in the circuits under 600V working

voltage, operating to prevent the faults from extending by detecting,

alarming or blocking the leakage current through ZCT in case of

occurrence of leakage in the ZCT load circuit.

6, 8, 10, 12, 16 circuits available

Item Relay Elements

Contro Voltage AC / DC 110 ~ 220V

Rated ZCT 200mA / 100mV

Rated Current 0.2A ~ 0.5A ~ 1.0A

A collective type relay that integrates multi circuits (16/ 1 circuits) of the conventional single circuit ground fault relay into one device.

This relay is for communication and individual contacts, also

available for a wide range of settings such as light grounding,

heavy grounding, etc.

Item Relay Elements

Contro Voltage AC / DC 80 ~ 256V

Rated ZCT 200mA / 100mV

Operating Current 0.1 ~ 10.0A (0.1A STEP)

Operating Time 0.05 ~ 10.0SEC (0.05S STEP)

Purpose

• NGR is a reactor to limit ground fault current at secondary neutron

point of power transformer.

• 3Ø 45 / 60MVA 154KV / 22.9KV, KEPCO

• Applied standard : IEC60289, IEC60076-11

Characteristics

• Independent air core structure supported with base insulator on

ground

• Strong enough to resist to electron mechanical power in case that

current flows in

• Highly efficient ventilation structure

Reactance 0.6Ω (60Hz) Insulating Class H Class (dry type)

Continuous current 300APeripheralTemperature

-25 ~ -40Short Time Current 10,000A / 10 sec.

Dry Type Neutral Grounding Reactor Purchase Inquiry 95 p

Digital Over Current Relay with Reclosing Purchase Inquiry 96 p

Features of OCR, OCGR, UBOCR, and reclosing as per KEPCO purchase specification.

Digital protective relay with increased reliability based on the function of recording, saving, and analyzing fault waveforms, also

available for output contact set by users.

Item Specification

Relay Elements 50 / 5×3, 50N / 51N, 46, 50B, 79

Control Voltage AC / DC 80 ~ 256V

Instantaneous Short Circuit Over Current (50) 1.0 ~ 80.0A (0.1A step)

Time-limited Short Circuit Over Current (51) 0.1 ~ 12.0A (0.1A step)

Instantaneous Ground Over Current (50N) 1.0 ~ 40.0A (0.1A step)

Time-limited Ground Over Current (51N) 0.1 ~ 12.0A (0.1A step)

Current Unbalance (46) 0.1 ~ 4.0A (0.1A step)

OLT Instantaneous Over Current (50B) 5.0 ~ 80.0A (0.1A step)

Reclosing (79) 1-3 times set

EARTHING Purchase Inquiry 96 p

It is necessary for stable management by acquiring safety of human and improving function of facilities protection such as

communication set and electrical installation from electric shock

DIPR-K210 / K211

DED / DER Series

DGF-D16R / D08R

Page 14: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

24 25

Relay, Protective Equipment,

Protective Devices and Parts

Relay, Protective Equipment,

Protective Devices and Parts

Eliminate fundamental conditions of lightning strikes

• Reduce probability of direct lightning strikes to prevent accidents

caused by lightning strikes and secure safety for human life and

other damages

The amount of Corona Discharge increased

Increased durability with better insulation by attaching an additional polymer insulator

Preventing separation by the modified absorbing part on the top

Conductor of the Potential Relaxation Part

• Solving the problem of corrosion in areas of chloride attack by

replacing copper materials with stainless steel

Size (Excluding the base)

Full length : 400 / Weight : app. 2

3th GenerationBipolar Conventional Air Terminal

Purchase Inquiry 99 p

Eliminate fundamental conditions of lightning strikes

• Reduce probability of direct lightning strikes to prevent accidents

caused by lightning strikes and secure safety for h uman life and

other damages

Coated with special material

• Lowered spark-over voltage by a few kV ~ dozens of kV

Increased durability with better insulation by attaching an additional polymer insulator

Preventing separation by the modified absorbing part on the top

Conductor of the Potential Relaxation Part

• Solving the problem of corrosion in areas of chloride attack by

replacing copper materials with stainless steel

Size (Excluding the base)

Full length : 400 / Weight : app. 2

5th GenerationBipolar Conventional Air Terminal

Purchase Inquiry 99 p

OMNI B-140SS

OMNI B-140S

IEDs & RELAY Purchase Inquiry 97 p

The area of IEDs & RELAY equipment responsible for research and production of advanced IEDs, multi-functional relays and meters

Type

• VIPAM7000 / 5000 / 3500Plus / 3500 / 3500C / 3300-F / 3000

• VIDER-M20 / M5 / M4 / DC / RTU

Arc alarm Purchase Inquiry 98 p

Arc and spark detecting device for the symptoms of electrical fires in advance

Dimensions (W x L x H / m)

210×280×65

Standards (citcuit breaker)

•Korea Fire Institute

•Arc alarm

•UL 1699

Application 3P 4W (Less than 600 Voltage)

Current Transformation

Secondary rating : 5A

Power (V) 220V

Interface RS-232C, Contact, HMI

RemarksStand-alone type: storing historyReal-t ime moni tor ing type :monitors the system

Surge Protective Device Purchase Inquiry 98 p

Protection device for cutting off the inductive lightning surge by lightning, on / off surge in the power supply system, and inductive

start surge of loads such as the large capacity motors

SPD-40 SPD-80

Rated Working Voltage Un (V ~ ) 385 420

Continuous Operating Voltage UC (V ~ ) 385 420

Protection level Up (kV ~ ) 1.8 2.6

Standard Discharge Current In (8 / 20 us) kA 20 40

Max Current Capacity Imax (8 / 20 us) kA 40 80

Response Time (nS) 25

Operating Temperature -40 ~ +80

Relative Humidity 95% (25)

Connection Lead Cut-area () Max.25 Max.25

Ground Wire Cut-area () 16 16

Dimensions (W×L×H / mm) 36×90×63 36×90×63

Page 15: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

26 27

Relay, Protective Equipment,

Protective Devices and Parts

Relay, Protective Equipment,

Protective Devices and Parts

Certified as a New Excellent Product

A grounding module comprises with graphite and perlite to rapidly discharge lightning currents into earth to increase discharge

efficiency

Improved endurance against lightning currents or other external shocks and reduced weight for easy delivery and installation

40% reduced weight in comparison with the existing model

Strong water absorption and moisture retention

Keep low ground resistance

Specification Size : Ø260×1000 / Weight : 38±10%

Perlite Carbon Ground Module (NEP certified)

Purchase Inquiry 99 p

A grounding module comprises with graphite and perlite to rapidly discharge lightning currents into earth to increase discharge

efficiency

40% reduced weight in comparison with the existing model

Strong water absorption and moisture retention

Keep low ground resistance

Item Specification

OMNI G-1PA Size : Ø160×800 / Weight : 13 ±10%

OMNI G-2PA Size : Ø260×1000 / Weight : 39 ±10%

Perlite Carbon Ground Module (General Type)

Purchase Inquiry 99 p

OMNI G-2PS

OMNI G-1P

A grounding module comprises with graphite and perlite to rapidly discharge lightning currents into earth to increase discharge

efficiency

Instantaneously discharge inrush surge from lightning by using the characteristic that electric field is concentrated at the needle-

shaped discharge electrode

Easy to maintain low resistance in an area with adverse conditions of high resistivity

40% reduced weight in comparison with the existing model

Strong water absorption and moisture retention

Keep low ground resistance

Item Specification

OMNI G-1PA Size : Ø160×800 / Weight : 13±10%

OMNI G-2PA Size : Ø260×1000 / Weight : 39±10%

Perlite Carbon Ground Module (Needle Type)

Purchase Inquiry 99 p

OMNI G-1PA

OMNI G-2PA

OMNI G-2P

Eliminate fundamental conditions of lightning strikes

• Reduce probability of direct lightning strikes to prevent accidents

caused by lightning strikes and secure safety for human life and

other damages

Maximizes the discharge capacity of the first-generation bipolar conventional air terminal

Installed on buildings and structures to replace the existing lightning rod which absorbs lightning strike; this enables better discharge

dissipation of ground charge

Comes in different sizes to fit standard lightning protection system facility

Appropriate for standard usages

Size (Excluding the base)

Full length : 500 / Weight : app. 1.95

2th GenerationBipolar Conventional Air Terminal

Purchase Inquiry 99 p

Eliminate fundamental conditions of lightning strikes

• Reduce probability of direct lightning strikes to prevent accidents

caused by lightning strikes and secure safety for human life and

other damages

Installed on small stand-alone structures like CCTV to replace the existing lightning rod, which absorbs lightning strike, in order to

improve the discharge of ground charge

Increased durability with better insulation by attaching an additional polymer insulator

Preventing separation by the modified absorbing part on the top

Conductor of the Potential Relaxation Part

• Solving the problem of corrosion in areas of chloride attack by

replacing copper materials with stainless steel

Size (Excluding the base)

Full length : 525 / Weight : app. 2.4

2nd Generation Bipolar Conventional Air Terminal Economic Type

Purchase Inquiry 99 p

OMNI B-100

OMNI B-140H

Page 16: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

28 29

Relay, Protective Equipment,

Protective Devices and Parts

Relay, Protective Equipment,

Protective Devices and Parts

Integrated Triple Redundant Protective Relay TRIUMP™

Purchase Inquiry 99 p

The TRIUMP™ series feature the triple redundant key modules for protection, measurement, control, and monitoring. Its mutual

monitoring and voting algorithm ensure a higher reliability and

availability than standalone products. As it is designed to perform

safely even in a poor industrial environment, it offers the best

performance in protecting the systems in which reliability is critical.

Features

• Triple redundancy and voting logic of key modules

• Standardization by modularized hardware architecture

• Large capacity recording and analysis

• Dual touch type color graphic LCD HMI

• TRIUMP™ manager software

• Various media based communication protocols

Overcurrent protection relay Purchase Inquiry 100 p

The product operates by over current which occurs during power system faults and it is designed to fit with protection, monitoring,

control & measurement in the distribution line.

Features

•Overcurrent protection function (50 / 51,50N / 51N)

•Unbalanced alarm function (UBOC)

•OLTC Blocking function

•Measurement function for each phase current

•Self-diagnosis function

•Monitoring and control function

•Fault recording and Analysis function

Model YSOC-7900A

Control power DC 90 ~ 140V

Rated Current AC 5A

InputCurrent 4ea (A,B,C,N-phase current)

digital 3ea (CB-b, Trip blocking, Clear)

OutputControl 5ea (‘a’×4ea, ‘b’×1ea)

Alarm 9ea (‘a’×8ea, ‘b’×1ea)

CommunicationFront RS-232C

Rear RS-485 (Option)

Dimension 172×226×253 (mm)

Facility Protection in Explosive Area

Power & Communication Combined SPD

Remote Monitoring System

Instant alarm and warning with remote monitoring

Item Specification

Explosion Proof Enclosure

•Size : 310×350×198• Explosion Proof Level : IEC EX d ⅡB T6 (Explosion-proof construction for internal pressure)

•IP Protection Level : IP 66•Material : Aluminium alloy

SPD for Power Supply

•ClassⅠIimp 20 Combination•3 phase 4 wire 380 / 220V•UP : L-N 3.5, N-PE 2.5• Normal Voltage, Surge Counter, amount of sure current, fault display, temperature of MOV, memory of time of events

SPD for Communication

Unit

•DC 24V•Category C2 6 / 3•6 pairs (12Lines)• Fault display, surge counter, memory of time of events

Monitoring System

•Measure voltage at each phase•Surge current display•Event memory and warning display•DD / MM / YY Data Display•Data graph provided

Explosion Proof Surge Protective Device Purchase Inquiry 99 p

OMNI EPA2-4YC

GE Protective Relay : UR, 8 Series Purchase Inquiry 99 p

YPP sets up an automation system for plants and power generators ECMS, utilizing top-notch digital protective relays and network.

YPP’s protective relays (UR, 8Series) offer enhanced features

such as the highest safety and high speed, with modular unit for

maintenance and convenience.

Features

• High performance protection, expandable I / O, integrated

monitoring and metering, high-speed communications, and

extensive programming and configuration capabilities

• High-end solutions for complex protection, control & automation

applications

• Optimum user friendly Software

• Advanced breaker diagnostics with high-end fault and disturbance

recording

Page 17: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

30 31

Relay, Protective Equipment,

Protective Devices and Parts

Relay, Protective Equipment,

Protective Devices and Parts

DC ground processing system Purchase Inquiry 100 p

The product have the alarm output function per each channel & fault record function in case the ground fault is occurred, As it is

always monitoring the leakage current in DC power supply line(P/

N phase) at the power plant or substation through communication-

type CT.

Features• Digital protection relay based on realtime operation• Detect fault signal by communication-type CT• Measurement method by removing noise signal• Possible to set the fault detection method per channel• Easily extend and select channels

• Monitoring and control function by communication interface

Product Types

Purchase Inquiry 101 p

Usage : a protective device restricting the lightening or switching surges, also blocking the follow current in electrical power systems

Characteristics

• Gapless arrester, Easier delivery and installation due to being light-

weight, High lightning protection performance, Excellent durability,

Available for ground isolator option.

Type 18kV 5kA 18kV 2.5kA

Rated Voltage 18kV 18kV

Nominal Discharge Current 5kA 2.5kA

Maximum Continuous Operating Voltage 15.3 (kV,rms) 15.3 (kV,rms)

Reference Voltage (D.C 1mA,kV) Over 22.9 Over 22.9

Lightning Residual Voltage Under 60 Under 60

Applicable Standards IEEE 60099-4 IEEE C62.11

Polymer Arrester

Purchase Inquiry 102 p

Grounding Materials

Lightnning Protection Materials

Semiconductor Solid Control Relay Purchase Inquiry 100 p

Interlock Module Device Purchase Inquiry 100 p

This product is the fast programmable logic controller of 154 / 345kV Interlock Panel. This hybrid system is combined with the sealed-

relay and power semiconductor element to replace with the analog

keep relay in existing panel.

Features•Interlock logic function based on PLC •Remote control function

•Constant monitoring system •Connector lock type

•Convenient user interface •Event record system

Model YSIM-2250M

Control power DC 125V±20%

Contact Capacity

Input Local DC 125V

OutputCB control (Contactless)

IGBT 1200V 25A

〃CB control (Reed)

16A 250VAC, 125VDC

〃 Interlock alarm 8A 250VAC, 250VDC

Operating time

CB operationON Within 35ms

OFF Within 200ms

Latch relayON Within 20ms

OFF Within 20ms

Dimension 552×311×81 (mm)

The product is the fast programmable logic controller in LCP of 25.8kV GIS. This hybrid system is combined with the sealed relay

and power semiconductor element to replace with the existing

relays used in Gas Insulated Switchgear.

Features

• Interlock logic function based on PLC

• Remote control function • Realtime monitoring function

• Convenient program upload • Connector lock type

• Energy saving

Model YSSR-0230

Control power DC 125V±20%

Contact Capacity

Input Local DC 125V

〃 Scada DC 24V

OutputSemiconductor devices

IGBT 1200V 25A

〃 Sealed Reed 5A 250VAC, 30VDC

Operating time

Semiconductor ON Within 16ms

Sealed relay ON Within 20ms

Operating time Circuit breakerTrip Within 16ms

Close Within 16ms

Dimension 380×218×71 (mm)

Model DGPS-C60, C30

Control power AC 65-240V or DC 125V 20%

Rated voltage DC 125V 10%

Inputvoltage 1ea (DC line voltage)

control 2ea (SCADA reset, Spare)

Outputsignal generator AC 30 ~ 65V, 27.5Hz

alarm 4ea (‘a’×3ea, ‘a1b’×1ea)

Communicationfront RS-232C

rear RS-485×6ea

Dimension 400×191×110 (mm)

Page 18: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

32 33

Relay, Protective Equipment,

Protective Devices and Parts

Relay, Protective Equipment,

Protective Devices and Parts

Usage : Metering Out Fit for electricity supply and demand is used in combination with the watt-hour meter, var-hour meter, or de-

mand meter.

Characteristics

• Use of epoxy bushing, No partial discharge, CT/PT special design

Maximum Circuit Voltage 25.8kV

Phase 3P4W

Current

5 / 5A ~ 15 / 5A 150ln

20 / 5A ~ 50 / 5A 75ln

75 / 5A ~ 200 / 5A 40ln

Level 0.5W Insulation Level 25.8 / 50 / 150kV

Load 3×25VA Weights 170kg

Metering Out Fit (MOF) Purchase Inquiry 102 p

Feeder Terminal Unit (FTU)

FTU is a remote terminal unit for distribution automation which controls and monitors switches on the distribution lines and

measures various electrical quantities of the line and transmits data

to control center through remote communication. Our FTU has

optimized function for various automation switches and support

various media and protocols for SCADA.

Item Description

FTU-R200 Automatic Circuit Recloser control

FTU-P200 Pole-mounted Load Break Switch control

FTU-C200 Ring Main Circuit Breaker (RING MAIN UNIT)

FTU-GD100 Pad-mounted multi circuits LBS

Purchase Inquiry 103 p

PAC Series

According to the trend which is switched to digital type for power control protection method rapidly, digital & economical protection

relay is in demand for substation of building, apartment, plant as a

fully digital system.

PNC Tech’s digital protection relay can satisfy with these customer’s

needs perfectly.

Item Description

PAC-X SERIESMulti-functional

Generator / Transformer protection

PAC-SERIESMulti-functional protection relay series for Feeder, Motor,

Transformer etc.

PAC-E SERIES Economical protection relay series

Purchase Inquiry 103 p

Digital Power Meter

PNC Tech’s DPM (Digital Power Meter) series has High brightness LCD and measurement with high accuracy & reliability. It also

supports standard communication protocol-RS485, Modbus.

Item Description

DPM-B200Measurement of 3 phases voltage, current,

PF, Frequency, etc.

DPM-B250 DPM-B200+ CB Control function

Purchase Inquiry 103 p

Protection Relay Equipment (GIPAM) Purchase Inquiry 104 p

DI / DO, AI / AO, selection of 2nd PT rate, HMI separation possible

Current, voltage, measurement accuracy of 0.2%

Support various dual communication and IEC61850 (TE) communication

Sag, Swell, Interruption & Harmonics, THD, TDD, K-Factor function

Page 19: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

35

Meter, Measuring Instrument and Parts

The digital panel meter is designed to that The indicated value can be read directly, like the switchboard meter. ltcan be variously used

as metering devices in such as switchboard and SCADA, and it will

do the monitoring and metering in the power system.

Also this is suitable device for the monitoring system formation

because it is possible to interface with the host system through RS-

485. This product is multi function meter that dimension is applied

the DIN standards.

Product Category Separation

Voltmeter

AC 1phase

AC 3phase

DC

Ammeter

AC 1phase

AC 3phase

DC

Wattmeter

1. measuring

2. measuring & contact & communication

Varmeter

Power Factor Meter

Frequency Meter

Indicator

Watt-hour & Var-hour

Telemeter

Max / Min Demand Meter

Multi Power Meter

Digital Panel Meter

Purchase Inquiry 95 p

General Specification

•Standard Test Tempeature : 23±2

•Moving Method : Pivod & the spring-mounted jewel

•Meter Position of Use : Vertical (⊥)

•Color of case : Black (Munsell No N1.5)

•Material of Cover Case : Polycarbonate resin / ABS resin

•Material of Terminal plate W type : Phenol resin or ABS resin

•Scale Plate : S type : White, W type : Platform type

•Full Scale Deflection : S type ≒90°, W type ≒250°

•Pointer : Sword Type, Black

• Principle of Operation Moving Coil type, Rectifier type, Transducer

type

•Dielectric Strength : AC 2000 / 1 minute

•Insulation Resistance : 500V Megger / ≥10

Product Category Separation

VoltmeterAC

DC

Ammeter AC

DC

Wattmeter 1P2W, 1P3W, 3P3W, 3P4W

Varmeter 1P2W, 1P3W, 3P3W, 3P4W

Power Factor meter 1P2W, 1P3W, 3P3W, 3P4W

Frequency meter

Maximum Demand meter

Vo

Ao

Watt

Var

Meter Relay Hi, Low, Hi Low limited

Insulation Resistance meter -

Indicator meter -

Panel & Switchboard Meter

Purchase Inquiry 95 p

Page 20: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

36 37

Meter, Measuring Instrument and Parts

Meter, Measuring Instrument and Parts

Type : Displacement Type Level Transmitter

Principle : The change of power applied to the displacer according to the change of the fluid level is generated in the form of a twist

stress to the Torque Tube, and the twist angle is changed into a

straight movement through a complicated mechanism conveyed to

the road cell in the form of a pressure change. The errors entailing

the temperature change is fixed with a supplementary circuit, and

put out in precise DC 4∼20mA of ±0.2%

Range : 350mm ~ 2000mm, Temperature : 최대 450

Pressure : Max 200 /

Features

•Zero point / automatic adjustment of the measured scope

•The measurement scope’s setting change function

•Precision of ±0.2% F.S

•Continuous self-diagnosis function

•Convenient level detection Scope change

• Remote control by two-wire type SMART + HART communication

Information transmission and reception, Data Logging, Gauge

history management

•FIMS-AMS communication support (Emerson Co.)

• Essential safety explosion proof (basic) / Pressure-endurable and

explosion proof (Option)- (Ex ia ⅡC T4) / (Ex d ⅡB T4)

Application

•Power plant HP, IP, LP Drum level control

•Condensed water storage tank, heat exchanger, Heater

•High temperature / pressure type Boiler tank

•chemical distillation tank

•Fuel / oil tank

•Others

Type : Tank Level Gauge

Principle : A measuring tape with holes in it in certain intervals are used to overcome length errors according to the temperature

change. Also, the device is made so that direct reading from the

lower part of the tank could be possible using the Guide Pipe. In

addition, the float is designed to be large and big so that it could

sensitively respond to the fluid’s level change, and a Seal Pipe

Type which can be used for tanks that have pressure, or possibility

of corrosion or leak of explosive gas, is also manufactured. It was

developed exclusively for large scale oil storage containers such as

petroleum tanks.

Temperature : -40∼120

Pressure : Max 5 /

Features

• Successful joint research on basic technology upon the request of

the Ministry of Commerce, Industry and Energy

•Precise measurement of ±2mm

•Able to install at the top / side parts

•On-site / remote control and alarm function

•Max. Range 20 M

•Seal Pipe Type (Magnetic float)

•Explosion proof type possible (Ex d ⅡB T6)

• Able to provide various accessories that can adjust to the on-site

process (Seal pot,etc.)

Application

• Large oil storage tanks, Petroleum tanks

• Eater reserves, Dams, Wells

• Others

Type : Displacement Type Level Switch

Principle : When the gravity of the Displacer sinking into the fluid gradually decreases with the rise of the level, the compression

spring which had been supporting the displacer’s weight slowly

returns to its original level, and the metal connected to the upper

part of the spring pushes out the Micro Switch connected to

the magnet, and the electric contact in each grade according

to the number of the displacers is putout. It can be used in high

temperature / pressure, and Max. five displacers can be installed

Range : 5000m

Pressure : Max 30 /

Features

•Low cost •Easy to install at places with low ceilings •Applied to

high pressure / temperature tanks •ON-site level control and width

adjustment •Chamber type also possible •Explosion proof type

possible (Ex d ⅡB T3)

Application

•Sewage processing plant •Water purification plant •Chemical tank

•Fuel and oil tank •Beverage tank •High temperature / pressure

tank

SDT-420

Purchase Inquiry 98 p

SMC

Purchase Inquiry 98 p

SLT

Purchase Inquiry 98 p

SMC-7 Series

Purchase Inquiry 98 p

Type : Vertical Float Type Level Switch

Principle : This Product is a unique level switch as a critical Process Instrument covering high pressure and high temperature.

Chamber material for this product is not only carbon steel, but

also many variety steel materials including 316LSS and 304SS.

This product han been produced for suitable in water

and boi ler control process, mett ing various industr ial

standards and requirements to solve erroneous causes

that have occurred in convent io inal industr ia l f ie lds.

The customizing for this product is possible for specific operational

condition and anti-corrosion. Please contact our sales staff if you

have any special design for ths product.

Temperature : -40∼400

Pressure : Max 70 Bar

Features

• Can be used for vessel under high pressure and temperature

•Weather poof / Explosion proof / Frame proof

•Unique and reliable : Snap acting switch mechanism

•Vibration resistant - eliminates fate trips by special spring

•A wide variety of chambers can be used

• Multiple switches can be assembled in a unit for economical

purpose

•Qualified to IEEE 323-2003, and IEEE 344-2004

•Applicable to hermetical seal type snap action switch

Page 21: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

38 39

Meter, Measuring Instrument and Parts

Meter, Measuring Instrument and Parts

AMI & Smart Meter Purchase Inquiry 99 p

YPP’s remote metering system using next generation electricity meters realizes the concept of Green Management by collecting

detailed information in addition to the conventional metering data.

With the integrated management system and the home-network

links, it is possible to access the management program to use

various services.

By searching and processing the metering data, it is possible to

analyze and discover the users’ patterns, which can lead to the

optimization of energy consumption.

• Controlling and reducing the electricity cost

• Pre-payment system to prevent theft of power and maximize the

management features

• Efficient management of energy consumption values by allowing

remote metering of water, gas, heat, and air-conditioning

• Sync with home automation and home network

• Systematic and convenient management of the consumption data

• Establishing power sales system in connection with the DR system.

ProCT1000MD Purchase Inquiry 102 p

ProCT1000MD–Current Transformer Tester

Rated Voltage

Output Voltage / Current

Measurement

AC 220V, 60Hz

0 ~ 1,200Vac@1Amax0 ~ 600Vac@1Amax0 ~ 150Vac@1Amax0 ~ 40Vac@1Amax

• Secondary winding Voltage : 0 ~ 1,200V, resolution 0.1V• Primary winding Voltage : 0 ~ 10,000mV, resolution 1mV• Secondary winding Current : 0 ~ 1,200mA, resolution 1mA• Accuracy : ±0.5%

PS34A Power Transformer Tester Purchase Inquiry 102 p

PS34A – Power Transformer Tester

Power Source Measurement

1φ, 220V, 5A, 60Hz

Voltmeters Range : 10 ~ 400[Vac]Ammeter Range : 0 ~ 50[A] (short current) 0 ~ 100[mA] (exciting current)Accuracy : ±1.0%

ART-7 Purchase Inquiry 102 p

ART-7 -Auxiliary Relay Tester

InputAC Voltage Regulator AC 220V, 60HZDC Voltage Regulator AC 220V

OutputAC Voltage Regulator AC 0 ~ 250V 60HZDC Voltage Regulator AC 220V

Electronic Electricity Meter

Purchase Inquiry 98 p

Just Fit for AMI System and User convenience

(Communication Interface for User)

By-direct (Export and Import), Active Reactive, apparent

Tamper Proof, Max Demand, TOU, LP

IEC 62056, DLMS Protocol

Interface by RS485 with PLC, RF ZigBee, CDMA, GSM, Module and speed 9,600 ~ 38,400 bps

Load Control on Latch Relay (Direct / Remote)

ItemsModel

1 phase 2 wire 3 phase 4 wire 1 phase 2 wire

Rated Voltage (V) 220 220 / 380 220

Rated Current (A) 100 (10) 50 (5)

Meter Constant (Pulse / kWh)

1,000

Accuracy (Class) Active 1.0 / Reactive 2.0

Rated frequency (Hz) 60Hz

Channel (CH) 8 channel (or 4 channel)

Operating temperature ()

-40 ~ 65

Dimension (mm)150 (W) / 160 (H)

81 (D)194 (W) / 221.5 (H)

81 (D)95 (W) / 114 (H)54.5 (D)

Page 22: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

40

Meter, Measuring Instrument and Parts

KR2000 Purchase Inquiry 103 p

Graphic recorder

High-speed collection 100ms / All channel

A simple manipulation

Degree of fixation ± 0.1%

LAN Response network

Channel-to-channel insulation 1000V

Measuring points

6p, 12pExternal memory

8GB CF Card

Rated supply voltage

100 ~ 240V AC input types Multi Range

Internal memory

Flash Memory 4MBAccuracy ratings

±0.1%±1digit

Metering devices (AMR, E-WHM)

Purchase Inquiry 104 p

Easy to connect : positive terminal connection type

Various types available : General type, pulse output type, remote monitoring type

Designed to protect from water, and dust (In compliance with IEC60529, IP51)

Distinction between left and right type not required (can use either load side, power side)

Easy to read measurement values with large LCD screen

Measurement data saved permanently even during the power outage

PSDR-XU Fault Recording Device

Characteristics

•Analog input 32CH (variable)

•Rated voltage 110V, rated current 5A, 1A

•DC voltage -10 ~ 10V, DC current 4 ~ 20mA

•Digital input 64CH (variable)

•DC : 24V

Details

•Digital output 4CH

•Relay output (a/b contact option available)

•Capacity : 120VAC / 0.6A, 110DC / 0.6A, 30VDC / 2A

Purchase Inquiry 102 p

Page 23: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

42 43

Plant Equipment and Instrument

Plant Equipment and Instrument

High voltage generator for electrostatic precipitator (EP) consists of transformer for outdoor rectifier (T / R) and indoor control panel.

Transformer for outdoor rectifier supplies high DC voltage and

current necessary for electric precipitation. The output voltage

of T / R should remain close to ignition point for effective work of

electric precipitation. T / R consists of transformer, current limiting

reactor and rectifier that is formed by single-phase half wave

rectification, including high-speed switching.

The parts embedded in oil tank should be completely sealed

and painted for outdoor purpose. Control panel contains thyristor

elements and all thea electric parts necessary to protect and

monitor high power units.

Major Client : Thermal Power Plant, Chemical Power Plant, District Heating Corp., etc.

Constant Single-phase Control Power

110VAC Rectifying Method

Single-phase wave rectifying method

OutputVoltage

DC30KV ~ 120KV / 100 ~ 2000mA Input

Voltage220 ~ 480V

High Voltage Generator for ElectrostaticPrecipitator (EP)

Purchase Inquiry 95 p

Air Cooler / Radiator Purchase Inquiry 97 p

Air Cooling Radiator is on of the Heat Exchanger System to reduce the temperature of hot fluids using ambient Air by Fan blowing. No

water for Cooling medium required is obvious advantage of this unit

which measns the Plants require huge amount of cooling capacity

is not necessary to be located around water-supplied area. This is

one of the Heat Transfer Devices. This system, using an around Air

through the Fan is designed to cool the hot flueds in tube.

The Plate type Heat Exchanger is structured with the Frames, rubber gaskets, and Heat Transfer Plates using anticorrosive

materials such as Titanium and Stainless Steels. The basic working

principle is heat or cool one fluid by transferring heat between it

and another fluid through the corrugated shape of Plates. This

is mostly using of Main Engine cooler and Generator Engine of

Vessel. This has a major advantage over a conventional heat

exchanger in that the fluids are exposed to a much larger surface

area because the fluids spread out over the plates. And it gives

high heat transfer efficiency, Compact design, Low cost of facility,

Easy installment & capacity changes.

Plate Heat Exchanger Purchase Inquiry 97 p

The primary function of condenser is to receive the exhaust steam from the steam turbine and reject a latent heat to the cooling

water so that the condensate may be pumped back through a

condensate system into the boiler. The condensate must be free

of impurities, either gases or solids which give damage to other

parts of the power cycle. The volume reduction resulting from the

condensation of steam produces a vacuum in the condenser. By

means of this vacuum, various drains can be led to the condenser.

SURFACE CONDENSER Purchase Inquiry 97 p

Feed water heater is utilized to heat the feed water with steam from turbine. And this is served to improve the cycle efficiency of power

plant and to minimize the thermal effect result from the difference of

temperature between steam generator and feed water. Generally,

HP Feed water heater is located posterior to deaerator and LP feed

water heater is prior to deaerator. Usually U-tube is used in feed

water heater that has 3 zones (super-heating zone, condensing

zone and sub-cooling zone).

Feed Water Heater Purchase Inquiry 97 p

Ejector Condenser Purchase Inquiry 97 p

It is the device that combines Ejector (to maintain a constant vacuum state by using the steam, driven by steam in Vacuum Steam

Condenser) and the Condenser (for reuse by condensation).

Page 24: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

44 45

Plant Equipment and Instrument

Plant Equipment and Instrument

Electric Heater uses the Electric as a main heating medium while Shell & Tube type Heaters use Steam. This unit has same

application with them as Oil heater, Purifier heater, Pre-heater, etc.

ELECTRIC HEATER Purchase Inquiry 97 p

Pressure Vessel Purchase Inquiry 97 p

A pressure vessel is a container designed to hold gases or liquids at a pressure substantially different from the ambient pressure.

When increasing its temperature of Lube Oil, it shall be burnt off or be changed its properties. Then the Lube Oil shall not cool the

other fluids properly. So, the main purpose of this cooler is to cool

the Lube Oils for adequate lubrication and cooling.

Lube Oil Cooler Purchase Inquiry 97 p

Control input / output air volume of the desulfurization system by adjusting exhaust gas through the control of ventilator pitch blade

as the system frequency / load varies, that is, through the control of

booster fan pitch blade opening.

Control the blowing / inflowing air amount depending to the generator’s output.

Perform the follow operation depending on the generator’s output.

Model Specification Applications

Desulfurization System BSTF Hydraulic Cylinder

170mm×96mmThermal power plant desulfurization system

Desulfurization System BSTF Hydraulic Cylinder

Purchase Inquiry 99 p

An actuator used in the turbine steam supply valve of nuclear and thermal power plants.

Serve to open the turbine steam supply valve coupled with the valve, and adjust turbine output power by controlling the supplied

steam amount when the valve is open.

Protect the turbine by immediately closing the supply valve, stopping the turbine in the emergency case with turbine protection

alarm signals.

Model Specification Applications

MSV Actuator 10” Nuclear plant

MSV Actuator 9” Thermal power plant

CV Actuator 10” Nuclear plant

CV Actuator 6” Thermal power plant

RSV (ISV) Actuator 8” Nuclear / therma power plant

IV Actuator 5” Nuclear / therma power plant

Turbine Valve Hydraulic Actuator Purchase Inquiry 99 p

Fan Pitch Blade Control Actuator Purchase Inquiry 99 p

Adjust output by controlling the pitch blades of ventilating facilities as the system frequency/load varies.

FDF (Forced Draft Fan)

• Inflate air for burning fuel inside a boiler.

IDF (Induced Draft Fan)

• Discharge exhaust gas from the inside of a boiler after fuel burn-out

BUF (Booster Fan)

• Force the exhaust gas through the desulfurization system by in-

creasing the air pressure.

Model Specification Applications

FDF (Forced Draft Fan) Ø336 50kW-grade domestic large scale

boilersIDF (Induced Draft Fan) Ø415

BUF (Booster Fan) Ø336

Page 25: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

46 47

Plant Equipment and Instrument

Plant Equipment and Instrument

Fast Response RTD (Coolant Temperature Sensor)

Purchase Inquiry 100 p

Coolant Temperature Sensor in reactor

Model WJ - FRT - SK05D

Size200±0.2Ω PLATINUM AT 0, Dual

CONN. HD EXT TYPE / SIZE : S.S HEAD / 3.6”

Instrument for checking position of Control Rod

Model CEPI - W01K

RSPT (Reed Switch Position Transmitter)

Purchase Inquiry 100 p

HJTC (Coolant Level Sensor)

Purchase Inquiry 100 p

Instrument for measuring Coolant level in reactor

Model WJ - HJTC - 01

ICI Assembly (Nuclear Fission Sensor in Reactor)

Purchase Inquiry 100 p

Instrument for measuring nuclear fission condition in reactor

Model WJ - ICI

Spray Valve for Deaerator

•Flow rate (Design) : 75 GPM

•Pressure Drop : 0.14 /

Model Standard Material

Spray Valve 2-1 / 2” A743-CF8M

(DSV) A743-CF3M

Spray Vavle Purchase Inquiry 102 p

Tray Assembly for Deaerator

•16 Gauge Stainless Steel

•8 Trays per Assembly

Model Standard Material

Tray Ass’ys 37” / 30” / 24” S’STL 430

S’STL 316L

S’STL 304

Spray Tray Purchase Inquiry 102 p

API610 BB5 Type Pump for Oil & Gas Plant (Model-SBRD)

Purchase Inquiry 103 p

Heavy Duty Design with Centerline Support

High Efficiency & Reliability

Compact Design Applicable for Wide Range of Liquids

• Flow : 600m3 / h, Head : 1,200m, Power : 2,200kW

Page 26: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

48 49

Plant Equipment and Instrument

Plant Equipment and Instrument

Boiler Feedwater Pump for 1,000MW Thermal Power Plant (Model-SBVD)

Purchase Inquiry 103 p

High Efficiency Hydralic Design

High Pressure & Temperature Reliability

Long-term Life Cycle by Contactless Throttle Bush Seal

• Flow : 2,000m3 / h, Head : 3,600m, Power : 21,000kW

Circulating Water Pump for Nuclear Power Plant (1,400MW) (Model-VMF)

Purchase Inquiry 103 p

High Efficiency

Low NPSHre

Low Vibration

• Flow : 61,000m3 / h, Head : 15m, Power : 3,100kW

BHI has acquired all of our boiler licenses from Amec-Foster Wheeler. For PC Boiler BHI can produce up to supercritical and

above. For Oil & Gas Boiler BHI can produce up to subcritical and

same goes with our CFB Boiler.

For all types of boilers, BHI can provide full scope of services starting from basic design, detailed design, manufacturing design,

and up to fabrication, supervision and erection.

Surface Condenser Purchase Inquiry 104 p

BHI is a world-class supplier of steam surface condensers. BHI has designed and manufactured surface condensers for a wide

range of power plants, with profound technical understanding and

extensive manufacturing experience.

Our steam surface condenser offers an evolution of advanced

technology, offering maximum thermal efficiency and superior

mechanical design to reduce forced outages and increase

availability.

BHI designs and manufactures high-quality products based on time-proven technology acquired from the License Agreement with

Amec Foster Wheeler in 2005, along with BHI’s own experiences

accumulated over time. BHI HRSG have superior design features

which make them more reliable and easier to maintain and service.

For HRSG, BHI is capable of basic design, detailed design,

procurement, fabrication, quality inspection, vendor control, erection

and supervision which means that BHI can provide our client with

all aspects of services.

HRSG (Heat Recovery Steam Generator)

Purchase Inquiry 104 p

BOILER Purchase Inquiry 104 p

Page 27: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

51

Wiring and Raceway Supplies

Busduct use Copper and Aluminum as a conductor, its current capacity is high and electrical and mechanical characteristics

is better than the cables. it also has an advantage on non-

flammability and safety, by using metal exterior.

Compared to the traditional wiring system, the installation

procedure of the busway system is easier, the installation space

can be saved, and it has an extra advantage on high-rise

building construction site.

Model Conductor Remark

Al-Al Type Aluminum Aluminum

Cu-Al Type Copper Aluminum

Al-Fe Type Aluminum Iron (Steel)

Cu-Fe Type Copper Iron (Steel)

Busduct Purchase Inquiry 96 p

It is able to bind and tighten cable and usuful in living, industrial etc.

CABLE TIE

It is to fasten cable and to support axial force. Cleat is actually impacted by several types of external forces, it is

to reduce the electromagnetic force which impact most in

accident of cable short circuit.

CABLE CLEAT

Purchase Inquiry 96 pPurchase Inquiry 96 p

Copper rod Purchase Inquiry 96 p

Copper rod has diverse applications, as it has excellent electricity & heat conductivity, machinability and corrosion resistance. It is used

in diverse industrial base metal such as power & communication

cables, coils, specialty cables, trolley wires and electronics

components. We produce 99.9% pure and high-quality rod, and

provide diverse size rod depending on the customers’demand, from

8mm power cable rod to 25mm railway rod for high-speed trains.

Size (mm)

Use

2.6 Magnet wire, Data cable, etc

8.0 Magnet wire, Data cable, etc

9.5 Flat wire

12.7 Flat wire

Size (mm)

Use

16.0 Flat wire

18.0 Trolley wire

23.0 Trolley wire for high speed train

25.0 Trolley wire for high speed train

Page 28: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

52 53

Wiring and Raceway Supplies

Wiring and Raceway Supplies

CABLE GLAND

It is to tighten to prevent ingression of water or dust when cable pass through particular area or equipment.

It has industrial & Ex-proof type.

TERMINAL LUG

Terminal Lug to terminate cable. Compression lug is to connect cable with cable and cable with terminal block.

Purchase Inquiry 96 pPurchase Inquiry 96 p

Used primarily to support the transmission lines , the shape is different depending on the terrain , transmission power and voltage of the line.

Each shape in consideration of the installation conditions (voltage, the span, height, etc. ) and designing by structured review

Various shape of structures and type such as Angle steel transmission tower (154kV, 345kV) and Tubular steel transmission pole (345kV,

765kV)

Type Transmission voltage

Angle steel 154kV, 345kV

Tubular type 345kV, 765kV

Transmission Tower Purchase Inquiry 97 p

By installing cable head on arm, it is convenient to have a work space to inspect equipments

It is possible to inspect equipments and reduce an inspection area.

The product has excellent structural stability, an elegant appearance and its environmentally friendly.

Install polymer support insulator to reduce arrester load and jumper wire deflection.

Product Config. Type

154kV Vertical, Horizontal

345kV Horizontal

Tubular Steel Pole Purchase Inquiry 97 p

Terminal Block is usuful product to maintain when cable is connected to terminal block when pass thruoghfrom inner

to out of panel instead of direct pass or divide to several

strand from one strand when connect many cables.

TERMINAL BLOCK

Purchase Inquiry 96 p

It is to connect, separate and protect cable and to acquire safety

Joint Box Junction Box

Purchase Inquiry 96 p

Present two poles can be replace by Y type steel pole. It can be reduce road occupation and settle a civil complaint

Can alternative installation for H pole when service to Extra high voltage customer

6 Pole Tr. can installing on one Y-pole and adopt for the over loaded area.

Type Designed Strength Install Type (Height)

16m 700kgf Land embedment (13.2m)

Y-Type Steel Pole Purchase Inquiry 97 p

Applied SPA-H material for Anti corrosion, no galvanizing and painting needed

Color Variation (Brown, Light Grey, Dark Green)

Lowering the maintenance cost

Treatment and transportation easier than Concrete pole

Increase the distance between poles and safe for external impact because of its’ high strength character

Type Designed Strength Install type (Height)

10M 500kgf Land embedment (8.3m)

12M 500kgf Land embedment (10m)

14M 700kgf Land embedment (11.6m)

16M 700kgf Land embedment (13.5m)

18M 2000kgf Land embedment (18m)

20M 2000kgf Land embedment (20m)

Weathering Steel Pole (Distribution Line)

Purchase Inquiry 97 p

Page 29: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

54 55

Wiring and Raceway Supplies

Wiring and Raceway Supplies

Adopt high-strength material (POSH690) to reduce raw material usage. More lighter than conventional product but the strength is

same

Light weight, easy transportation and installation

Dimension Designed aStrength Product weight

90×90×3.5T×2400 1200kgf 21kg

High Strenth Unified Strain Crossarm Purchase Inquiry 97 p

Quality installation with standardized products at work and reduce the install construction cost

Reduce the material costs compared to existing installed products

Type1 Circuit

2 Circuit

Cable Head Supporting bracket

Adopt high-strength material (POSH690) to reduce raw material usage. More lighter than conventional product but

the strength is same

Light weight, easy transportation and installation

Dimension Designed Strength Product Weight

75×75×1.8T×2400 1000kgf 10kg

High Strength Cross Arm

Purchase Inquiry 97 pPurchase Inquiry 97 p

Relieve discomfort during the die casting operations of the manhole

Neat and clean surface of the manhole

Secure the space inside the manhole

No water leakage, Maintenance free

Type175mm

200mm

Conduit Material for Underground Cable

Purchase Inquiry 97 p

Self Angle adjustment ( (±15°)

The length shorter compared to conventional hangers and it can widened the workspace

Shorten the installation time and increasing the efficiency

Type L X W Adoption

CL-M3 R28×L150 325 Bottom Support

CL-CC R28×L150 325 Top Fixing

Cable Hanger Support Purchase Inquiry 97 p

Easy installation at construction site

Neat, Clean, Good durability

Type175mm

200mm

Kit Coupler Purchase Inquiry 97 p

Page 30: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

56 57

Wiring and Raceway Supplies

Wiring and Raceway Supplies

SIM performs induction bend which is a part of shop fabricated piping as an independent business. We manufacture and supply induction

bend through 1.5DR small radius making technology.

category specification

Bending Radius Minimum 1.5DR ~

External Diameter 1″ ~ 80″

Angle ~ Max 270°

Production Capacity 1,600 Ton / Month

INDUCTION BEND Purchase Inquiry 98 p

Under international code like ASME, DNV, KEPIC, SIM performs engineering, procurement, fabrication, inspection and packing to

make piping spools in the special shop. SIM also supplies piping

spools with power plant and on / off shore plant to construct it easily

on site.

Typical applicable material Production Capacity (Ton / Month)

Carbon Steel 2,350

Alloy 1,200

SUS & Non Ferrous 1,250

Total 4,800

SHOP FABRICATED PIPING Purchase Inquiry 98 p

SIM produces and exports induction bending machine with an excellent mechanical design and manufacturing technology.

category specification

Bending Radius Minimum 1.5DR ~

External Diameter 1″ ~ 80″

Angle ~ Max 270°

INDUCTION BENDING MACHINE Purchase Inquiry 98 pPolymer Suspension Insulator

Light weight : Lighter than porcelain insulator, providing easy work and shortened period of

construction (reducing power interference by shortened electricity failure time)

Elastic body : Easier handing and transportation by reduced damage from careless

Weather resistance : Reducing maintenance cost without need for washing or cleaning

Water repellency : Excellent insulation performance with water-resistion properties

Type Section Length Leakage Distance

15kV 330mm 439mm

25kV 445mm 642mm

35kV 539mm 850mm

Purchase Inquiry 97 p

excelline “S” excelline “P”

excelline working drawingexcelline “M”

excelline (Modular Wiring System)

Purchase Inquiry 99 p

excelline is a new assembling method, which realized exposed and variable assembling through simple connection. As wiring, piping

and connecting can be constructed in an integrated and convenient

way using a product, preassembled and connected at a factory,

construction, maintenance and management of a building can be

conducted with high efficiency.

모델 설명

S• A power supply instrument, connected to a joint box for power lead-in through a box connector and whose plug port is connected to a lamp

M

• As a branching device, installed in a lamp, it composes branch lines of 2way, 3way and 4way under a main line

and has lead wires for connecting to a lamp so that a

circuit can be connected to 4 ways as necessary.

P• Being connected to <M>, which is installed in a lamp, it connects between lamps electrically.

Page 31: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

58 59

Wiring and Raceway Supplies

Wiring and Raceway Supplies

Usage : Elbow connectors connecting between the main bushing and cable installed within 25kV 600Amp above-ground switches,

with a shielding part and insulating part made of special perox-

ide-crosslinked EPDM, making works easier with excellent insula-

tion, durability, water-proof, and flexibility.

Characteristics

• Semi-permanent, high water-proof and durability, easier works,

water-repellent property, reuse and reconstruction available.

25kV 600Amp Switch Connector Purchase Inquiry 102 p

Rating Specification

Impulse Withstand Voltage

125BIL (kV)

1 Min. Dry WithstandVoltage (A.C.)

40kV

Rating Specification

Partial Discharge22.8kV / 3pC or less

Rated Voltage 25.8kV

Rated Current 600A

Usage : Used to connect two different cables, having a heat dis-sipation effect due to an unique clover shaped internal structure

while keeping the same structure as a cable.

Characteristics

• Special design for electric field distribution; underground direct

burial available; excellent insulation property, water-repellent prop-

erty, reconstruction and reuse available.

Rating 15PCJ 25PCJ 35PCJ

System Votage 15kV 25kV 35kV

Impulse Voltage (1.2×50us) 110kV 240kV 240kV

Paftial Discharge (Corona) 15.6kV 25.8kV 30kV

15min. Dry Withstand (D.C.) 65kV 75kV 125kV

6hr. Dry Withstand (A.C.) 36kV 53kV 69kV

25kV Cable Joint Kit Purchase Inquiry 102 p

Usage : Integrated cable termination kit used for releasing electric field distribution, sealing the terminating end of a cable, and pre-

venting flashover in the cable terminating works.

Characteristics

• Semi-permanent, easier works in the confined space, excellent

insulation property, excellent tracking-resistant property, reusable.

Rating Specification

25SMT is dseigned for use on SystemVoltage 25kV

Impulse Voltage (1.2×50us) 150kV

Paftial Discharge (Corona) 21.5kV / 3pC

15min. Dry Withstand (D.C.) 105kV

1min. Dry Withstand (A.C.) 65kV

25kV Cable Termination Kit Purchase Inquiry 102 p

Polymer(silicon rubber) suspension insulator(flame proof type, gen-eral tensile force) used for 154kV extra-high voltage overhead

transmission lines.

Characteristics

•Easier works due to being lightweigh

•durable •self-cleaning features.

•Excellent mechanical property

• Polymer materials with high water-repellency.

Specification SR-25N SR-25F SR-36N SR-36F

Leakage Distance 3,098mm 4,445mm 3,124mm 4,343mm

Dry Arcing Distance 1,375mm 1,400mm 1,313mm 1,456mm

Power Frequency Dry Flashover Voltage

506kV 539kV 529kV 559kV

Power Frequency Wet Flashover Voltage

450kV 478kV 470kV 495kV

Lightening Residual Flashover Voltage (positive)

836kV 890kV 875kV 924kV

Lightening Residual Flashover Voltage (negative)

891kV 946kV 931kV 981kV

Minimum Tensile Fracture Load 111.2kN 160.1kN

Transmission Line Insulator Purchase Inquiry 102 p

Polymer Suspension Insulator

Polymer (EPDM rubber) suspension insulator used for extra-high voltage overhead electric lines.

Characteristics

• Easier works due to being lightweight

• durable •self-cleaning features.

• High water-repellent property • Excellent mechanical property

• good erosion-resistant property.

ITEM UnitDN-15ED-CT

DN-28ED-CT

DN-35ED-CT

Voltage Class kV 15 28 35

Net Weight kg 4 6 8

Section Length (L) mm 1.26 1.40 1.55

Shed Dimeter (D) mm 336 446 531

Leakage Distance mm 415 643 851

Dry Arcing Distance mm 204 314 389

60HzFlashover

DRY kV 100 130 145

WET kV 70 110 130

ImpulseFlashover

Positive kV 140 190 250

Negative kV 175 230 275

Min.Spccifed Mechanical Load kN 70 (15,000)

Min.Torsional Load N-m 55 (40)

Purchase Inquiry 102 p

Page 32: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

60 61

Wiring and Raceway Supplies

Wiring and Raceway Supplies

Car Tubes

We have a wide product range of car tubes, including protection tubes for auto brake pipes, fuel pipes, gas springs and electronic

tubes.

Model Purpose

GSHS-2690MW Brake Pipe Protection

LS-2690R Fuel Pipe Protection

GSHS-3625WS

Electronic TubeGSHS-4635WS

GSHS-4650WS

Purchase Inquiry 104 p

Busduct_Ez / Ex / Ef-way

LS Cable & System E-series Bus duct can be used for applications carrying up to AC 1000V and currents from 630A to

7500A. When connected using a joint kit the connected surface

is very large thus minimizing contact resistance, and basically

IP54 level can be realized. It can be produced in both exterior

and interior IP65 configuration, and interior IP42 according to

application requirements. The E-series is classified into three

types according to insulation: Ez / Ex / Ef-way. As an option, a

single-bolt structure is feasible whereby the connector conductor

connects directly without a joint kit.

Model Insulation Purpose

LT-WAY Air Commercial

MINI-WAY Air Commercial

EX-WAY Epoxy Commercial

CR-WAY Cast Resin Plant

NSPBAirEpoxyCast Resin

Plant

Purchase Inquiry 104 pStructured Cabling SystemPremises Communication

LS Cable & System total wire end-to-end building solutions provide optimized solutions for the physical infrastructure and management

of total Voice / Data / Video communication.

It provides globally standardized products for flame-resistant

products.

LS Cable & System LAN provides voice communication Cat.3

solutions, and UTP Cat.6A solution for 10G data transmission, which

is the recent trend in the communication industry (10Gbps, 500MHz,

10GBASE-T, cables with world’s-smallest external diameter of 7mm,

6 Channel authentication).

Category Product

Copper Solution Copper cable Copper Connectivity

Fiber Optic Solution Fiber Distribution Frame Outlet Module

Work Area Solution Face Plate, Back Box, Surface Mounted Box

CATV Solution ECX, HFBT Coaxial Cable

Purchase Inquiry 104 p

Electric, Electronic, Power Supplies

Purchase Inquiry 104 p

Terminals Class-1E (Q), Non Class-1E (S)

Compression Terminals & Casting Lugs

Sleeves

Cable Ties

Terminal Blocks

Wire Connectors

Accessory & Tools

Page 33: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

62

Wiring and Raceway Supplies

System is economically viable new power supply / distribution method that improved on the inconveniences caused by the existing cable power supply / distribution method and that introduced the concept of decentralized power feeding system for the individual oad type of products when it comes to the power supply whitch facilitates installation and movement for installation. Moreever, this is a convenient power supply system that ensures that the power box for getthing supplied with power can be inserted and installed easily at any location where Section is installed instead of the fixated location.

Model degree of Protection Rated Voltage

PLUG IN TYPE IP54 / 65 600V below

NSPB IP54 / 65 3.3kV ~ 35kV

Busway Systems Purchase Inquiry 95 p

Purchase Inquiry 101 p

Lite-Way designed for end-to-end connections to form a continuous assembly, shall be permitted to contain the conductors and made it form a modular unit length. Lite-Way identified for through-wiring, as permitted by overcurrent protection, shall be permitted to be used as a raceway. Lite-Way Installation method of improved 2-steps identified for construction, shall be used prominently to reduce the labour cost of Previoue 5-steps method. Lite-Way luminaires connected and combined with metal raceway, as made a form a unit, shall not be only attachable and also detachable any time required.

Product Model Size

LITE-WAY(LED)

LT70-R20W-SI57K AC220V, LED 20W

LT70-R40W-SI57K AC220V, LED 40W

LITE-WAY(FL)

LT70-R32W1/U AC220V, FLR 32W 1 Lamp

LT100-S32W2/U AC220V, FLR 32W 2 Lamp

LT70-R28W1/U AC220V, FHF 28W 1 Lamp

LT100-S28W2/U AC220V, FHF 28W 2 Lamp

Purchase Inquiry 101 p

Multi-functions together for Raceway, Wiring, Multi-box and Power branch in a unit Multi-Wire-Duct shall necessarily be separated by partitions for EMC screening and ground bonding shall be done at the point of screw bolts. Fabricated with extruded aluminum or aluminum alloy with powder coating.

Model Size

WA35 70 x 35 x 2m

WA50 70 x 50 x 2m

WB50 125 x 50 x 2m

WD70 140 x 70 x 2m

Switchgear, Distribution Panel Switchgear, Distribution Panel Switchgear, Distribution Paneland Control Panel and Control Panel

Page 34: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

64 65

Switchgear, Distribution Panel

and Control Panel

Switchgear, Distribution Panel

and Control Panel

12kV Metal Clad Switchgear

Air insulated and compact Internal Arc resistance Mechanical interlock for safety

Model SDMG-10M / P SDMG-24M

Rated Voltage (kV) 12 24

Rated Current (A) 2000 / 1250 1250

Rated Interrupting Current (kA) 40 25

Rated power frequency withstand voltage (kV / min)

28 50

Rated lighting impulse voltage (kV) 75 125

Internal arc classification AFLR -

Internal arc current (kA) 40 -

Internal arc Duration (s) 1 -

Purchase Inquiry 98 p

IntelligentPower Distribution Panel

Intelligent power distribution panel which can be remotely controlled and monitored the distribution panel’s information (via server, smart phone)

1. Arc / Spark Sensing the Arc and Spark which are the direct causes of electric fire, and make an Alarm to prevent Fire

2. Input Power Make an Alarm when the Main Electricity outage

3. Leakages Monitoring the Leakages for each breakers and make an Alarm if there is Leakage current occurred

4. Over current Monitoring the Over Current for each Breakers and make an Alarm if over current occurred

5. Over LoadMonitoring the Over Load on the Main line, Indicate inside LED by %, and make an Alarm if Load exceeded settled percentage (75%)

6. Door Open Cabinet door open

7. NORMAL Operating in normal status

8. Checkup Checkup required

9. RESET Reset the Monitoring status

Purchase Inquiry 98 p

Motor Control Center Purchase Inquiry 98 p

Easy maintenance Design in accordance with IEC61439-1 Arc- proof design

Model X-cell 213 (Back to back)

Rated Voltage (kV) 480

Rated Current (A) 3150 / 600

Rated short circuit Current (kA) 65 / 143 (pick)

Rated power frequency withstand voltage (kV / min)

2 (min)

Rated lighting impulse voltage (kV) 9.8

Internal arc current (kA) 65

Internal arc Duration (s) 0.1

Low Voltage Switchgear & MCC

Gas Insulated Cubicle type Switchgear (C-GIS)

Low Voltage Switchgear from our company adopting standard components boasts high reputation with the efficient cost and

delivery in the market, and especially secures high reliability

demonstrated by a variety of type tests including the seismic test

for plants such as nuclear plant, hydraulic power plant and thermal

power plant.

Model degree of Protection Rated Voltage

KSL-600 IP4X 600V

KNL-600 IP4X 600V

C-GIS is consisted as vacuum circuit breaker, 3-position switch, sliding type bus connecting system, limiting type power fuse and

control devices for electrically and mechanically protection.

The Metal-clad design provides high reliability, economical benefit,

Client will friendly operation and safety.

Model degree of Protection Rated Voltage

33 CST IP65 / IP4X 25.8kV

High Voltage Switchgear

Medium-voltage Metal-clad Switchgear is designed in accordance with domestic and international standards. We have concentrated

on establishing the strong reliability basis and have devoted on

development and research for manufacturing product featuring high

safety, low cost and easy assembling / disassembling, ensuring to

client convenient for maintenance.

Model degree of Protection Rated Voltage

KSM-V7.2 IP4X 7.2kV

KSM-V12 IP4X 12kV

KSM-V24 IP4X 24kV

KSM-V33 IP4X 36kV

Purchase Inquiry 95 p

Purchase Inquiry 95 p

Purchase Inquiry 95 p

Page 35: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

66 67

Switchgear, Distribution Panel

and Control Panel

Switchgear, Distribution Panel

and Control Panel

C-GIS Purchase Inquiry 103 p

Successfully maintain a competitive edge in quailty, price and delivery through cotinuous research and development

offer the best solutions in the field of electric power distribution, protection, measuring, control and communication

Model Rated Current Rated Voltage Applicable standards

HMS-G81 / 821,250 / 2,500 / 3,150A

~ 38kV IEC 62271-200

Medium Voltage Metal Clad Switchgear – Solution Power

Incoming Panel and main circuit PT Panel can be configured with one side

Distribution panel with highest protection level, compartment with metal wall

Convenient to maintain and high reliability by adopting LSIS’s Susol VCB

Equipped with Internal Arc feature

IEC62271-200 Standard

Rated voltage Rated current Breaking capacity

~ 36kV ~ 4000A ~ 50kA

Purchase Inquiry 104 p

Motor Control Center– Solution2000

Obtained ASTA international test certification

Prevents spread of the accident by installing arc shield plate at perpendicular busbar

Design structure that can include up to 13 basic units or 26 100A MCCB units

Rated voltage Rated current Breaking capacity

~ 480V ~ 4000A ~ 80kA

Purchase Inquiry 104 p

High Voltage / Low VoltageDistribution Board / MCC PNL

Purchase Inquiry 100 p

High Voltage / Low Voltage / Distribution Board

Switchboard is divided into HV / TR / LV and performs the function of each

Use Excellent Breaker (VCB, ACB) Receiving superior design emphasized on functionality and reliability

Applications•Power Plant, Substation•Power receiving equipment of industrial Plant•Power receiving equipment of building• Power receiving and distributing equipment of Water and Sewage Treatment System

MCC PNL

High performance, high reliability, safe operation

Protection and control system for low voltage motor

High performance, high reliability

Applications• Steel / Cement plant• Power plant• Semi-conductor factory• Petrochemical plant• Subway• Other Industrial plant

MCC PNL24kv High Voltage Switchgear

Low Voltage Switchgear Distribution Board

inside

154kV Transmission Line Protection Panel

Apply to 154kV transmission line protection and PCM differential current protection for short distance transmission which support IEC 61850 standard for communication.

Characteristics •Function selection in accordance with 3 type MODE selection - DIF : 87 (PCM current differential relay) + 79 (reclosing)- DIFDZ : 87 (PCM current differential relay) + 21 distance relay)- DZ : 21 (distance relay)

•PCM communication IEEE C37.94

•IEC 61850 communication- 1 front Port : Serial 100 Base-T / 100BASE-TX Ehernet communication port- 2 rear Port : 100 BASE FX Ethernet communication port (Multi Mode)

• GPS interface IRIG-B120 or using ST optical connector

•Breaker control function

•3 phase trip

Purchase Inquiry 100 p

Page 36: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

69

Transformer, UPS

Power Transformer Purchase Inquiry 95 p

Power transformer is a device to transmit power from power plant to substation. It is widely used in industrial faculties such as

substations and factory.

It is manufactured in accordance with international standard and

KS Standards. We customize our design of power transformer to

customer’s specifications to meet their satisfaction.

ConstantSingle-phase, Three-phase

Capacity 60MVA or lower

Frequency 50, 60Hz Voltage 69KV or lower

Cast Resin Transformer Purchase Inquiry 95 p

Since epoxy resin is molded in vacuum state, it is very resistant to humidity and environment-friendly. In addition, it uses

specially treated glass for excellent mechanical strength.

It maintains optimal state of insulation thanks to the coil surface

treated with special finishing work.

Since it is of superior self-extinguishability, there is no risk of fire conduction and poisonous gas during combustion.

Its partial discharging value is low due to the latest vacuum casting technology applied (lower than 10pC)

ConstantSingle-phase, Three-phase

Capacity 10MVA or lower

Frequency 50, 60Hz Voltage 36KV or lower

Automatic Step Voltage Regulator (SVR)

Purchase Inquiry 95 p

Based on our long-cumulated know-how and experience, SVR is the product that we succeeded in developing first in Korea under

technology introduction contract with U.S. Cooper Power System.

Characteristics • This regulator maintains phase-to-phase voltage within a certain range

and helps motor, lights and machine run properly.

Constant Single-phase BIL 95, 150, 200 Voltage 11, 22, 33KV±10%

Frequency 50, 60HzCurrent Up to 640A

Tank Type Round, Square Tap Changer 32 Steps Picture of Installation Case (PVR 7000KVA)

Page 37: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

70 71

Transformer, UPS

Transformer, UPS

PAD Transformer

On-ground transformer is designed for underground distribution facility, streetlights, place adjacent to residential area, school,

building, hospital and factory. It is possible to install it near

downtown load area. Since it is equipped with protection fuse and

fault current limiting fuse, it can prevent damage to transformer and

error expansion in case of error in transformer.

External power connection unit is designed to be completely

insulated. It has radian and loop type transformer. In addition, it can

be structured in both open and close type.

ConstantSingle-phase, Three-phase

Capacity Less than 3000KVA

Frequency 50, 60Hz Voltage Less than 36KV

Purchase Inquiry 95 p

Main Transformer for Electromotive Car

It receives AC 25K high voltage current from wire (Catenary), changes it to necessary voltage and transmits power

to main electricmotor through main power converter at

secondary (conventional) side or to auxiliary circuit through

auxiliary power supply system at the third (tertiary) side.

Our company produced transformer for railway vehicle first in Korea and is currently developing next-generation train main transformer,

emerging as market reader in the domestic market.

Major Client : Korea Railroad Corporation, Hyundai Rotem and others.

Rated Capacity 20KVA ~ 8900KVA

Input 25000V-840-1548V-221V

Output 25000V-840V-929V AC

ConstantSingle-phase, Three-phase

Capacity Less than 3000KVA

Frequency 50, 60Hz Voltage Less than 36KV

Purchase Inquiry 95 p

Characteristics

• N+1 parallel operation

• Online double conversion DSP control

• Input THDi : <3%

• Voltage options of storage battery : 16 / 19 / 20PCS

• Load power factor : 0.9PF

• Input voltage tolerance range : 120 ~ 276Vac

• Input frequency tolerance range : 54 ~ 66Hz

• Energy-saving ECO mode

• Self-monitoring USP start

• Angular interface (SNMP, Relay Card, Parallel Card

Uninterruptible Power System (UPS)

Purchase Inquiry 95 p

Distribution Transformer

Distribution transformer functions to receive high voltage from distribution lines and supply necessary voltage to users.

It is divided into indoor and outdoor distribution transformer. We customize production to customers’ order and needs.

ConstantSingle-phase, Three-phase

Capacity 30MVA or lower

Frequency 50, 60Hz Voltage 69KV or lower

Purchase Inquiry 95 p

Pole Mounted Transformer

Pole transformer is installed in the distribution lines of KEPCO. It is usually installed on electric poles to lower high voltage.

Constant Single-phase Capacity 10-150KVA

Frequency 50, 60Hz Voltage 36KV or lower

·Type : Oil, Amorphous Core

Purchase Inquiry 95 p

Dry Type Transformer for UPS, B / CH, AVR

It is a dry type transformer installed in power supply unit for UPS

Characteristics• Environment-friendly (highly efficient, small in size, light and low

noise)

•Long life cycle and solid structure

Major Client : KEPCO, KHNP, Thermal Power Plant, etc.

Rated Capacity 150KVA ~ 1,000KVA

Input 220 ~ 480AC Output 216 ~ 540VAC

Insulating Class B, F, H Class Frequency 50, 60Hz

Purchase Inquiry 95 p

Page 38: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

72 73

Transformer, UPS

Transformer, UPS

HR Series UPS Purchase Inquiry 99 p

The HR Series UPS, which has been developed by YPP, is designed with a high performance DSP (Digital Signal Process) to

promptly and precisely process any failure of the power of the

equipment itself.

They can be relied on to perform their critical missions and useful information such as the waveform at the time of breakdown, the

numbers, and the condition of the equipment can be recorded. As

a result, the cause of a failure or breakdown can be traced down

and dealt with quickly and accurately.

Features

• High speed and precision using high-performance DSPs and

digital controls

• Guidance function for the startup or shutdown of UPS as

recommended on the screen: Users can easily and conveniently

operate the product.

• Black box function providing analysis of cause of failure

Automatic Voltage Regulator Purchase Inquiry 100 p

The product is Automatic Voltage Regulator to control On Load Tap Changer(OLTC) on the main transformer. It can control the

voltage according to each load characteristics. Also it can adjust

the voltage effectively by bus / line voltage drop as it include Digital

Voltage Meter(DVM) function too.

Features

•Advanced processing speed and accuracy

•DVM function

•Self-diagnosis function

•Tap operation of OLTC counting function

•Event data record

•Communication interface

Model YVC-03

Control power DC 125V±20%, AC85 ~ 245V (option)

Ratedcurrent AC 5A

voltage AC 60 ~ 160V

Input

current 1ea

voltage 1ea

digital 2ea (Volt-change 1, Volt-change 2)

Output

control 2ea (‘a’ x 2ea)

alarm 3ea (‘a’ x 2ea, ‘b’ x 1ea)

error 1ea (‘b’ x 1ea)

Communicationfront RS-232C

rear RS-485 (Option)

Dimension 205 x 240 x 177 (mm)

Automatic Voltage Regulator (AVR)

Purchase Inquiry 95 p

It adopts tap changing regulator that has less wave distortion than existing CVT that uses the magnetic saturation and resonance

phenomenon of metal pin It can maintain stable output voltage due

to high-speed switching.

Low noise and light weight

Quicker response than existing CVT method in terms of load and input change

Major Client : Nuclear plant (“Q”, “T”, “R” Class), KEPCO, Thermal Plant, etc.

Constant Single-phase, Three-phase

Frequency 50, 60Hz Input 110~480VAC±15%

Capacity 500KVA max. Output 110~480VAC±2%

GE UPS Purchase Inquiry 99 p

With the innovative technologies of YPP and quality planning, we develop products with the latest technology and the highest level

of service to ensure uninterrupted production and stable power

supply.

From desk-top applications to complex engineering products, our

diverse product line-up provides our customers with everything

they need to ensure quality and stability in their power supply

system, and includes the comprehensive maintenance agreement

services to cover all maintenance works, from basic power supply

equipment and batteries to the entire system.

Features

• Reduced operation costs through SBM

• Super Eco Mode (selected by the user) to reduce the energy cost

• Minimized space requirement for installation and operation by

maintenance of the front control panel

• Easy UP operation through convenient user interface

• Compliance with the international standards EMI (IEC62040-

2) and safety (IEC 62040-1) to ensure sufficient EMI and safety

performances.

Page 39: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

74 75

Transformer, UPS

Transformer, UPS

Amorphous Transformer(Oil&Dry type)

Reduce no-load loss by 75% comparing to conventional transformer

Save costs for operation & maintenance

Decrease secular variation of winding & insulating materials caused by passing years

Reduce heat emission by power consumption and prevent global warming from reducing emission of harmful gas

Cast Resin(Dry) type

Conventional Amorphous

Available up to 3P 15MVA Available up to 3P 7.5MVA

Oil-immersed type Available up to 3P 50MVA Available up to 3P 15MVA

Purchase Inquiry 101 p

Solid Insulation Distribution Transformer(SIDT)

Improved Safety

•Oil-free, Fire resistant and Self-extinguishing features

•Underground installation which eliminates

Environmental Effects

•Improves space utilization

•Removes obstacle on pavement

Operate in diverse applications

•Operate in wet, corrosive and dusty areas

Solid Insulation Distribution Transformer

Single Phase Three Phase

up to 167kVA up to 500kVA

Purchase Inquiry 101 p

Transformers Purchase Inquiry 103 p

High quality transformers up to 800kv, 150MVA, utilizing state of the art manufacturing/ teasting facilities, with stringent quailty control

system at every step of the manufacturing process

Meet all customer requirments in compliance with applicable industrial codes & standards

Optimized design for high performance and reliabilty

ISO 9001 quailty certified

Rated Capacity Rated VoltageAnnual Production

Capacity

5 ~ 1,500 MVA 22.9 ~ 800 kV 120,000 MVA

Mold Transformer

Non-Inflammability / High Impulse strength

High Insusceptibility / Maintenance free

High short circuit strength / low noise level

Minimize power losses

High Reliability(R-mark)

Power Range 10 ~ 1500kVA

Purchase Inquiry 100 p

ETUS 1(Full Digital Control by DSP)

Double Conversion

Low Input Harmonic(Thd : 5%) / IGBT PWM Rectifier&Inverter

High reliability / Low noise

Suited for Non-Linear Load / Suited for Unbalanced Load

Paralled operation without the additional master controller

Power Range 10 ~ 500kVA

Purchase Inquiry 100 p

ETUS2(Full IGBT Double Conversion driven by Vector Control running on DSP)

Transformer free design (Low Cost, Optimum Space)

Full IGBT double conversion (InputPF > 0.99, THDI < 5%)

Digital Vector Control (Excellent dynamic performance)

Scalability up to 2MV (Up to 4 UPS in parallel)

User Friendly LCD touch screen display

Remote Monitoring Interface (RS232, RS485, SNMP, TCP / IP)

Power Range 10 ~ 500kVA

Purchase Inquiry 100 p

Page 40: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

76

Transformer, UPS

Cast-Resin Transformers Purchase Inquiry 103 p

Compact Lightweight, Low loss & noise

Non-flammable and outstanding insulation performance

maintenance free, Self-extinguishing and environmetally frendly

Designed to withstand the highest mechanical short-circuit stress which may occur in service

ApplicationsWarehouse,underground, railways, sports stadiums,

and water retaining areas

Rated Capacity ~ 20MVA

Rated Voltage ~ 36kV

Applicable standards

IEC60076, KS C4311, IEEE Std C57.12.01

LS Cast Resin Transformer

Model 1st Voltage 2nd Voltage Capacity (kVA)

Standard Consumption Efficiency

22.9 / 6.6 / 3.3kV HV or LV ~ 3000kVA

Lowest Consumption Efficiency

22.9 / 6.6 / 3.3kV HV or LV ~ 3000kVA

General 22.9kV HV ~ 25000kVA

Purchase Inquiry 104 p

Page 41: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

78

New Renewable Energy

Main Shaft

Tower Flange

Purchase Inquiry 102 p

Purchase Inquiry 102 p

TAEWOONG’S Main Shaft for wind turbine has been a world-class product which has been approved by Korean government since

2006.

Main shaft transfers the rotary energy generated by the blades of

the wind turbine to the electric power generator. Strict management

is required from selection of raw material to a complete product

because wind power generator is needed for long durability.

TAEWOONG’S Tower Flange for wind tower has been a world-class product which has been approved by Korean government

since 2014. Tower flangesare ring-shaped connectors that are

used to assemble the bodies of the steel towers supporting the

wind turbines. Tower flange is an important wind power component

for tower connection which is installed with six or seven flanges in

a wind turbine.

Page 42: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

80 81

Cables

Cables

80 81

RF Cable Purchase Inquiry 96 p

RF Cable makes wireless communication possible in places where electronic waves cannot reach, such as tunnels, subways and

underground shopping districts.

Application Corrugation / Smooth wall type Outdoor conductor

Indoor HFX AL / CU

Tunnel,Underground

RCX AL / CU

Outdoor SWT / SWT Twin AL

CATV 5C, 7C, 10C, etc

Railway Signaling Cable Purchase Inquiry 96 p

Railway Signaling Cable make it possible to share diverse signaled information for operating trains, and used for the purposes such

as maintaining the minimum breaking distance and path linkage

between the preceding train and the following one, and limiting the

speed. TAIHAN succeeded in developing and commercializing the

‘Digi-code Signal Cable’, a cable for signal transmission applied to

the automatic protection system of trains, in 2013.

Use Description Remark

Telecommunication

Transmission

Voice Unification

Public Address

Wire Communication

Signalling

ATP

Track Circuit

Signal Facility Room

Overhead Conductor Purchase Inquiry 96 p

Overhead Conductors are used in overhead transmission and distribution network.

TAIHAN produces High Temperature Low sag conductors

including ACCC (Alumium Conductor Composite Core), which use

high-strength carbon fiber cores, as well as ACSS (Aluminum

Conductor Steel Supported), H-STACIR, and ACSR are

produced.

Model Core Aluminium

ACCC Carbon Fiber Coposite Core Full Annealed Aluminium

ACSS High Strength Steel Full Annealed Aluminium

H-STACIR Invar STAL

ACSR Galvanized Steel Hard Aluminium

High Voltage and Extra highVoltage Cable

High Voltage and Extra high Voltage cable are used to carry electric current. TAIHAN produces 500kV extra-high voltage

cables, the highest rating possible for underground cables, as well

as various XLPE and O.F cables.

Model Grade Remark

XLPE cable up to 500kV

O.F cable up to 400kV

Purchase Inquiry 96 p

Medium and Low Voltage cable means general distribution cables in the range of 0.6 / 1 ~ 33kV. We produce and supply reinforced

cables which are resistant to fire, watertight and with enhanced

fireproof capacity depending on its function.

TAIHAN also produces 33kV submarine cable for power distribution.

Model Grade Remark

LV / MV Power cable 0.6 ~ 35kV

Control cable 0.6 ~ 1kV

Submarine cable up to 33kV

MV / LV cable Purchase Inquiry 96 p

Data cable

UTP cables are used to transmit high-capacity data such as highspeed internet and IPTV. TAIHAN’s UTP cable has excellent

transmission efficiency as it is in CAT.6E class which is higher than

universal CAT.5E class.

shielded / Unshielded Category Remark

UTP Cat.6

UTP Cat.6A

FTP Cat.6

FTP Cat.6A

STP Cat.5e

STP Cat.6

Purchase Inquiry 96 p

Page 43: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

82 83

Cables

Cables

82 83

Distribution Cables LV / MV Cables

Distribution cables can be divided into mid-to-low voltage cables that provide power to large-scale industrial sites and commercial

buildings, control and instrumentation cables for signal transmission

among industrial facilities, and insulation cables for distribution to

electrical equipment and power supply to buildings.

Model Insulation Sheath

0.6 / 1kV F-CVV PVC FR-PVC

6 / 10kV F-CV XLPE FR-PVC

22.9kV FR-CN / CO-W

XLPE / TR-XPLE PVC

450 / 750V HFIX Halogen Free XLPO

Purchase Inquiry 104 p

Industrial Specialty Cables

Industrial special cables are important heavy-duty cables that carry power and signals to facilities and equipment in various fields, such

as shipbuilding, marine structures, wind power, nuclear power, mining

and railways. Non-toxic high-molecular materials are used, and

we are continuously developing products customized to the special

usage environment of each industry.

Category Product

Vessel Cables JIS, XLPE / SHF1, EPR / SHF1

Marine Cables NEK 606, Type P, BS

Navy Vessel Cables MIL-DTL, VG Type

Wind Power Cables WT-PXX, DLO

Nuclear Cables Q-FR-PH, FR-PN

Purchase Inquiry 104 p

DC Submarine Cables

The demand for DC submarine cables is continuously increasing due to (ultra) long-distance grid connections among countries and

power transmission from offshore wind power generation hubs to

the mainland. Low attenuation power transmission is feasible through

HVDC submarine cables.

LS Cable & System can produce extruded cross-linked

polyethylene (XLPE) and mass-impregnated non-draining (MIND) DC

submarine cables. We were the first Korean company to develop and

implement an HVDC 250kV MI submarine cable system.

Model Insulation Sheath

Windfarm Infield (AC 10 ~ 66kV) XLPE Cu wire, Lead

Windfarm Export (HVAC ~ 400kV) XLPE Lead

HVDC ~ 500kV MI Lead

HVDC ~ 320kV XLPE Lead

Purchase Inquiry 104 p

Extra-high Voltage_XLPE Insulation Cables

The basic material for XLPE is polyethylene, which is chemically transformed to cross-linked polyethylene (XLPE) through the cross-

link reaction of organic peroxides. The cross-link method for

polyethylene was developed in the United States during the 1950’s

and has since been continuously developed for application to

higher voltages. Higher voltages are increasingly being required,

and the 500kV XLPE cables have already been commercialized.

Model Insulation Sheath

66kV ~ 500kV XLPE Aluminum Sheath

66kV ~ 500kV XLPE Lead Sheath

66kV ~ 500kV XLPE Copper Wire Shield

Purchase Inquiry 104 p

TAIHAN is producing outdoor termination, which connects overhead conductor and underground cables together, the GIS termination,

which connects underground cables to GIS systems, as well as

Pre Molded Joint, Prefabricated Type Joint and Transition Joint that

capable up to 500kV that connect various types of cables together

Model Grade Remark

Termination up to 500kV

XLPE Joint up to 500kV

O.F Joing up to 400kV

Transition Joint up to 161kV

Epoxy insulator up to 500kV

Termination and Joint Purchase Inquiry 96 p

Overhead Wire_High Capacity Conductor

HCC, or High Capacity Conductors are new high-capacity, high-efficiency cables, when greater power supply is required compared

to ACSR. Such cables provide a solution for increased power

demand and high-capacity power transmission by using new

materials and technology. HCC provides the optimum solution for

various environments including urban, salty regions and long-span

transmission sections.

Model Detailed Information

TASCR Thermal Resistant Aluminum Alloy Conductors, Steel (Aluminum-clad Steel) ReinforcedTASCR-AW

Hi-TACSR High Tensi le Strength Thermal Resis tant Aluminum Alloy Conductors, Extra High Strength Steel ReinforcedHi-TACSR / EST

Hi-STACIR / AWSTACIR / AW

Super-Thermal Resistant Aluminum Al loy Conductors, Aluminum-clad Invar Reinforced

Purchase Inquiry 104 p

Page 44: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

84 85

Cables

Cables

84 85

Optical Cables

LS Cable & System opens a happier, richer future through providing total solutions for optical communication, which is required to create

an ultra-high-speed, multimedia world. We produce optical fiber,

optical cables, and optical connection materials.

Category Product

Fibers Single Mode / Multi Mode Fiber

Optic Cables Indoor / Outdoor Optic Cable

Optical Connection Materials

Optical Jumper Cord Optical Connector & Adaptor Optical Fiber Distribution

Purchase Inquiry 104 p

Indoor / Outdoor Transmission Line

The antenna feeder coaxial cables used for RF communication systems incorporate high foaming polyethylene insulation technology

to minimize signal loss. They have excellent electric features such

as low damping and reflection coefficient. Furthermore, they have

high flexion features due to high flexibility.

To meet the usage environment needs, flame-resistant polyethylene

has been applied as a safeguard against fire hazards. Flame and

fire-resistant sheaths are also used.

Model Detailed Information

HFC Series Flexible Foam Dielectric Feeder

HFSC Series Super Flexible Foam Dielectric Feeder

RFCX Series Radiating Cable

HFAC Series Flexible Foam Dielectric Aluminum Feeder

HFASC Series Super Flexible Foam Dielectric Aluminum Feeder

ECX Series Braided Feeder Cable

Purchase Inquiry 104 p

Industrial Devices_FA / Robot Cables

Factory Automation (FA) / robot cables are used for power supply and signal transmission for factory equipment and digitalization for

devices such as industrial robots. The conditions of industrial fields

and the movement of devices are becoming more complex, so we

are providing customized products that meet our customer’s needs.

In the field of factory automation / robot cables, LS Cable & System

aims for customer satisfaction based on the best technology in

Korea, and seeks to expand to larger markets.

Model Insulation Sheath

ROVV / SB PVC PVC

ROIREV / SB XPLE PVC

ROIREU / SB XPLE PU

ROFHV / SB Fluorine compound PVC

ROFHU / SB Fluorine compound PU

Purchase Inquiry 104 p

Automobiles Battery Cables

Wires for automotive batteries are wires used around the batteries in automobiles. Their specifications range from 10SQ to 100SQ, and

specifications are selected depending on where they are used and

current carrying capacity. They range from general battery cables

to high-flexibility battery cables.

Model Purpose

AV General Battery Cable

EB General Battery Cable

AVX Cross Linked Battery Cable

AEX Cross Linked Battery Cable

Purchase Inquiry 104 p

Harness & ModuleHigh-voltage Harness for Automobiles

The harness is like the nerves and blood vessels of a human body. It supplies power and electric control signals throughout

the vehicle through connectors, cables and other distributors. We

develop and supply battery packs for eco-friendly electrically

powered vehicle systems, and the harness and charging system

for main power systems of inverters and motors. LS Cable &

System provides optimized, customized connectivity products for

vehicle performance enhancement through the development of

insulators, electromagnetic wave shielding, assembly and system

development.

Model Detailed Information

High Voltage Connector

Low Current Connector 15 ~ 40AHigh Current Connector 15 ~ 40A

High Voltage Cable 125 ~ 200

Purchase Inquiry 104 p

Page 45: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

87

Rectifier, Charger, Inverter

87

Composed of diode, SCR and IGBT rectifier element, rectifier receives single-phase or three-phase power and yields direct

current. It is being more and more used in special power facility

and safety power facility as industrial facility gets more precise and

automated.

Major Client : Nuclear Plant (“S” Class), Thermal Plant, Chemical Plant, Iron and Steel Plant, etc.

Constant Single-phase, Three-phase

Frequency 50, 60Hz

Input 110 ~ 480VAC

Output 24 ~ 200VDC

Capacity 10 ~ 20000A

Rectifier (Dry and Oil Type) Purchase Inquiry 95 p

Composed of diode, SCR and IGBT rectifier element, recharger receives Single-phase or three-phase power and yields direct

current. It is be\-ing more and more used in special power facility

and safety power facility as industrial facility gets more precise and

automated.

Major Client : Nuclear Plant (“Q”, “T”, “R” Class), Thermal Plant, Chemical Plant, Iron and Steel Plant, etc

Frequency 50, 60Hz

Input Single-phase or Three phase 120 ~ 480VAC±15%

Output 100 ~ 280VDC±0.5%

Capacity 20 ~ 2000A

Battery Charger Purchase Inquiry 95 p

Inverter Purchase Inquiry 95 p

IEC is Various inverter production of high reliability and supply to the demand for already recognized for excellence of its

performance.

Major Client : Nuclear Plant (“Q”, “T”, “R” Class), Thermal Plant, Chemical Plant,

Iron and Steel Plant, etc.

Input 125 ~ 600VDC

Output 120 ~ 480VAC, 50, 60Hz

Capacity 5 ~ 400KVA

Rectifier, Charger, Inverter Rectifier, Charger, Inverter

Page 46: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

88 89

Rectifier, Charger, Inverter

Rectifier, Charger, Inverter

88 89

N5000 Medium Voltage Inverter Purchase Inquiry 103 p

Optional function to implement trip-free operation

• Cell-bypass, Redundant control power, Redundant control unit,

Redundant CAN communication

Maximized system efficiency and power factor

•System efficiency over 97% , power factor over 95%

Clean power input with 18-36 pulse configuration

•Compliance with IEEE 519-1992

Optimized power quality output with multi-level PWM method

Rated Voltage 3,300, 4,160, 6,600, 11,000, 13,800V

Applicable standards IEC, KS, IEEE, UL

N800S Low Voltage Inverter Purchase Inquiry 103 p

Available in all common voltages in the range of 208~480V with a wide power range up to 132kW.

Easy access terminals, built-in DIN rail mounting for Fast installation.

User-friendly keypad, the MCA parameter copying tool which can clone settings without main power in drive.

Built-in PLC functionality and programming

Rated Voltage 380 ~ 500V

Rated Capacity ~ 132KW

Rectifier

Thyristor Controlled Battery Chargers

Purchase Inquiry 100 p

Purchase Inquiry 100 p

Power Range : 2000 ~ 8000kW

Output voltage : 750V / 1500V

Features

•Bulk Rated Output Power

•6Pulse / 12Pulse type

•Easy-to-use structure

•Natural Air Cooling System

•Exclusive standards (NEMA, ANSI, EC, IEEE) Standards

Power Range : 3 ~ 1500kW

Output voltage : 24V, 48V, 125V, 250V DC

Features

•SCR 6Pulse&12Pulse Phase control High Re

Page 47: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

91

Utilization Equipment and others

91

size Type1 Type2

1 / 8” ~ 24” A312 Neck pipe

Stainless Seamless Pipe Purchase Inquiry 95 p

Steel structures formed by joining weld and bolt assembly to the H beam angle, etc.

Manufacturing the Structures of Commercial building, power plant, Boiler, Substation

Steel Structures Purchase Inquiry 97 p

We have developed the world’s first BWTS (Ballast water treatment system) of Plasma method named ‘ARA PLASMA BWTS’, and

received type approval from Korean government. System is

composed 4 parts, Filter, Plasma, MPUV, controller. Filter removes

particles and microorganisms that are bigger than 50μm. Plasma

generates shock wave and it kills and damages microorganisms

under 50 μm. Medium Pressure UV sterilizes the remained

microorganisms by exposing UV-C ray.

Our system has lots of advantages as follows. First, it is eco-

friendly system, because there is no by product and secondary

pollutant. Second, exceptional performance of Plasma in not only

dirty condition like high level of turbidity but also fresh water.

Capacity : 150m3 / hr ~ 1300m3 / hr

Ballast Water treatment system Purchase Inquiry 97 p

Page 48: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

92 93

Utilization Equipment and others

Utilization Equipment and others

92 93

PE coating is outstanding product which have both excellent mechanical property of steel pipe and rust prevention property of

plastic. Coating has resistance to seawater and organic solvents,

and also it does not contain dioxins and VOCs.

We maximize our technical efficiency to expand usage of PE/

PA coating from sea to land based on our core PE coating

technology.

(1) Durability (2) Safety (3) Impact resistance (4) Chemical resistance

PE COATING PIPE Purchase Inquiry 97 p

The water which is generated by fresh water generator in vessel, cannot be used by drinking water directly, because of pH value,

hardness none of mineral component. For using mineralizer,

increase hardness, pH value, mineral component.

Dolomite & re-hardening material are usually changed per 3month. (If pH value is lower than 6.5, recharging activity much be

done)

Capacity : 1000L / HR ~ 30,000L / HR

MINERALIZER (RE-HARDENING FILTER)

Purchase Inquiry 97 p

Low Voltage Induction Motor Purchase Inquiry 103 p

Hyundai rotating machinery has been supplied and tested in accordance with worldwide classification societies such as Lolyd’s

Register, ABS, DNV, and KR for marine and IEC, NEMA, CSA, IEEE,

KS, JEC, and AS for industrial applications.

Hyundai’s Cast Iron, Rolled Steel and Aluminum frames sharply improve motor performance by maximizing heat dissipation.

The use of advanced technology to design and produce electric motors allows the motor design to be maximized in both

performance and cost, providing the market with a superior quality

product at a reasonable price.

Rated Voltage Applicable standards

200 V, 208-230 / 460 V, 220 / 380 V, 230 / 400 V, 220 / 440 V, 415 V, 460 V, 575 V, 660 V, 690 V

NEMA MG1 & CSA C390, IEC 60034, IEC 60072

RO TYPE FESH WATER GENERATOR Purchase Inquiry 97 p

Reverse Osmosis is most commonly known for its use in drinking water purification from seawater, removing the salt and other

substances. Reverse Osmosis is the process of forcing a solvent

through a membrane from a region of high solute concentration to a

region of low solute concentration by applying a pressure in excess

of the osmotic pressure.

Capacity : 5TON / DAY ~ 200TON / DAY

Simple Construction

Easy Installation

Easy Maintenance

Easy Operation

The fresh water supply unit supplies fresh , warm and cold drinking water for the crew and It consists of technical system of water tank, sterilizer, re-hardening filter (mineralizer), calorifier and pumps.

Capacity : 1,000 ~ 10,000 L/hr

FRESH WATER SUPPLY UNIT Purchase Inquiry 97 p

UV STERILIZER Purchase Inquiry 97 p

The UV sterilizer of Samkun Century has superiority of operating system. It protects mineral components, but disinfect typical viruses,

colitis germs, bacteria in water. Emission of ultra violet rays :

253.7nm (Most effective wavelength for removing bacteria)

Capacity : 1000L / HR ~ 30,000L / HR

Page 49: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

95

Manufacture Company Introduction

Company Name

Address

Establishment

Phone

Homepage

E-mail

Gana Steel Co., Ltd.

1264-2, Seohae-ro, Paltan-myeon,

Hwaseong-si, Gyeonggi-do, Korea

Oct. 1984

82-2-584-4292

www.Ganasteel.com

[email protected]

Main Products • Seamless Stainless Pipe

Company Name

Address

Establishment

Phone

Homepage

E-mail

International Electric Co., Ltd.

98, Singaecheon-ro, Geumwang-eup,

Eumseong-gun, Chungcheongbuk-do, Korea

Feb. 1957

82-43-883-7751

www.ieckr.com

[email protected]

IEC is, I dare say, a medium scaled eletrical manufacturer with large potentials.In terms of items, we are producing various kinds of Transformers (Cast resin, Pole mounted, Ground mounted, Pad mounted etc..)up to 40MVA class and also are supplying UPS, EP-Rectifier, Battery Charger, Industrial use Rectifier, Voltage Regulator, Reactor, Mining Transformer, Traction and Locomotive Transformers. In terms of sales we have been keeping unchangeable domestic market sales and abroad.

Company Name

Address

Establishment

Phone

Homepage

E-mail

Kyongbo Electric Co., Ltd.

Seongsu-dong 2-ga Seongdong-gu,

Seoul, Korea

Feb. 1967

82-2-465-1133

www.kyongbo.co.kr

[email protected]

Main Products • Panel & Switchboard Meter• Current & Voltage Transformer• Power Transducer

• Digital Pannel Meter• Protective & Relay• ELD & ELR

Manufacture Company Introduction

Gana Steel

Kyongbo Electric

KwangMyung Electric

International Electric

Taihan Electric Wire

DONG-A BESTECH

DEESYS

RECTUSON

Mytec

BOSUNG POWERTEC

VITZROTECH

SAMKUM CENTURY

SATURN I&C

SeoJin Instech

Seondo Electric

SUNG IL

SEHONG

enesG

OMNI LPS

YPP

WOOJIN INC.

Yousung Instrument & Electric

YOUHO ELECTRIC IND.

EHWA TECHNOLOGIES INFORMATION

ENTEC ELECTRIC & ELECTRONIC

JEONO

Cheryong Electric

Jinwoo System

Taewoong

PESSCO

PYUNGIL

PROCOM Systems

PNC TECHNOLOGIES

KOREA CHINO

Hyundai Heavy Industries

HYOSUNG GOODSPRINGS

BHI

LSIS

LS Cable & System

Company Name

Address

Establishment

Phone

Homepage

E-mail

KwangMyung Electric Co., Ltd.

Head office : B2-15, 160 Moknae-ro, Danwon-gu, Ansan-si, Gyeonggi-do, 15597, KoreaSeoul office : KwangMyung B / D, 189 Ogeum-ro, Songpa-gu, Seoul, 05642, Korea

Jul. 1955

82-2-2240-8114

www.kmec.co.kr

[email protected]

Main Products • Switchgear •Gas Insulated Switchgear• Electrical Component •System business• New Renewable Energy Business

Page 50: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

96 97

Manufacture Company Introduction

Manufacture Company Introduction

Company Name

Address

Establishment

Phone

Homepage

E-mail

RECTUSON Co., Ltd.

59, Gwangnyeocheonnam-ro,Naeseo-eup,

MasanHoewon-gu, Changwon-si,

Gyeongsangnam-do, Korea

Jul. 2000

82-55-231-3333

www.rectuson.com

[email protected]

Main Products • AE System.• WCMS. (SCADA)

• BTLD. (Boiler Tube Leak Detection)• NIMS. (NSSS Integrity Monitoring System)

Company Name

Address

Establishment

Phone

Homepage

E-mail

DONG-A BESTECH Co., Ltd.

13-15, Samjeong-dong, Ojeong-gu,

Bucheon-si, Gyeonggi-do, Korea

Mar. 1977

82-32-675-0081

www.dongabestech.com

[email protected]

Main Products • Cable Accessory

Company Name

Address

Establishment

Phone

Homepage

E-mail

Taihan Electric Wire Co., Ltd.

Taihan Smart Tower, 317 Simin-daero,

Dongan-gu, Anyang-si, Gyeonggi-do, Korea

Feb. 1955

82-2-316-9114

www.taihan.com

[email protected]

• Power cable (HV / EHV Cable, MV / LV Cable, Overhead Conductor and Control cable etc.)• Cable Accessories (Joint, Termination and Epoxy insulator etc.)• Specialty Cables (Heating cable, Trolley wire and Factory automation cable etc.)• Communication Cables (RF cable and Data cable, Railway signaling cable etc.) • Base Metal (Copper rod, Magnet wire)

Company Name

Address

Establishment

Phone

Homepage

E-mail

DEESYS Co., Ltd.

160, Saksigalma-ro, Daegot-myeon,

Gimpo-si, Gyeonggi-do, Korea

Mar. 1979

82-31-987-8771

www.deesys.com

[email protected]

Main Products • All of Digital Power Protective Equipment • Earth Leakage Detector (ELD) • Protective Relay (OCR, OCGR, OVR, UVR, OVGR, DGR) • Ground Fault Relay (GFR) • Indicating Electric Instrument (Kinds of Meter) • Transformers (CT, VT, ZCT, etc.) • Epoxy molded post insulator and more

Company Name

Address

Establishment

Phone

Homepage

E-mail

BOSUNG POWERTEC Co., Ltd.

53, Daechang-gil, Judeok-eup, Chungju-si,

Chungcheongbuk-do, Korea

Nov. 1970

82-2-543-2211

www.bosungpower.co.kr

[email protected]

Main Products • Steel Tower• Tubular Tower (Structure)• Steel Frame• Electric Equipment for Distribution

• Electric Equipment for Under-ground Line

• Electric Protection Equipmen

Company Name

Address

Establishment

Phone

Homepage

E-mail

Mytec Co., Ltd.

33, 4ro Mieumsandan,Gangseo-gu, Busan,

South Korea

Aug. 2003

82-51-831-7474

www.imytec.com

[email protected]

Main Products • Heat Exchangers, Pressure Vessels &Industry Machinery

Company Name

Address

Establishment

Phone

Homepage

E-mail

VITZROTECH Co., Ltd.

327, Byeolmang-ro, Danwon-gu Ansan-si,

Gyeonggi-do, Korea

Jul. 1955

82-31-489-2000

www.vitzrotech.com

[email protected]

Main Products VITZROTECH has developed into a manufacturer of MV equipment, LV equipment, Switchgears, Protective Equipment and Relays in the domestic electric equipment business.• MV Equipment : VCB, VTB, MCB, VCS, VDS, VS, LBS, ASS, GLBS, CLPF • LV Equipment : ACB, MCCB, ELCB, ATS, MC• Switchgear : GIS, Eco-GIS, MCB (Metal Clad Switchgear), MCC• IED&Controller : VIPAM, VIMAC• Protective Device : SPD, LA, SA

Company Name

Address

Establishment

Phone

Homepage

E-mail

SAMKUN CENTURY Co., Ltd.

405, Miyul-ro, Samnangjin-eup,

Miryang-si, Gyeongsangnam-do, Korea

Nov. 1989

82-55-338-3030

www.samkunok.com

[email protected]

Main Products •BALLAST WATER TREATMENT SYSTEM •FRESH WATER SUPPLY PLANT •RO TYPE FRESH WATER GENERATOR •UV STERILIZER •PE COATING PIPE •MINERALIZER

Page 51: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

98 99

Manufacture Company Introduction

Manufacture Company Introduction

Company Name

Address

Establishment

Phone

Homepage

E-mail

SUNG IL Co., Ltd. (SIM)

45, Noksansandan 289-ro, Gangseo-gu,

Busan, Korea

Oct. 1978

82-51-831-8800

www.sungilsim.com

[email protected]

Main Products • SHOP FABRICATED PIPING• INDUCTION BEND• INDUCTION BENDING MACHINE

Company Name

Address

Establishment

Phone

Homepage

E-mail

Seondo Electric Co., Ltd.

86, Wonsi-ro, Danwon-gu, Ansan-si,

Gyeonggi-do, Korea

Jan. 1972

82-31-491-2284

www.seondo.co.kr

[email protected]

Main Products Switchgear, Motor Control Center, Gas Insulated Switchgear, Protection Relay Panel, Vacuum Circuit Breaker, HMI, CSD, RTU Distributed Control System, Negative Lon Generator, Solar etc.

Company Name

Address

Establishment

Phone

Homepage

E-mail

SeoJin Instech Co., Ltd.

12,Sagimakgol-ro 148beon-gil, Jungwon-gu,

Seongnam-si, Gyeonggi-do,462-807, Korea

Nov. 1979

82-31-627-9000

www.seojin.biz

[email protected]

Main Products • SDT-420 (Displacement Type Level Transmitter)• SLT (Tank Level Gauge)• SMC (Displacement Type Level Switch)• SMC-7series (Vertical Float Type)

Company Name

Address

Establishment

Phone

Homepage

E-mail

SATURN I&C

10, Yeouidaebang-ro 67-gil, yeongdeungpo-gu,

Seoul, Korea (Yoido-Dong, Oigyo Building)

Dec. 1996

82-2-761-3167

www.saturninfo.co.kr

[email protected]

Main Products • Arc alarm• Intelligent Distribution Board• Surge Potector

Company Name

Address

Establishment

Phone

Homepage

E-mail

YPP Co., Ltd.

24, Gasan digital 2-ro, Geumcheon-gu,

Seoul, Korea

Jan. 1982

82-2-2104-8770

www.yppdt.com

[email protected]

Main Products • ECMS & Protection Relay• Power and Plant Equipment Diagnostics

• SmartGrid, Smart Home, Smart Building

• Plant Control System• Energy Solutions–UPS, ESS, Fuel Cell e-BOP

• Energy Consulting & Power System Advanced Course

Company Name

Address

Establishment

Phone

Homepage

E-mail

OMNI LPS Co., Ltd.

Seonyudo Kolon Digital Tower 201~206,

Yangpyung-ro 22-gil 21, Youngdeungpo-gu,

Seoul Korea

Nov. 1997

82-2-2632-4541

www.omnilps.com

[email protected]

Main Products • Bipolar Conventional Air Terminals• Explosion-proof Surge Protective Device

• Perlite Ground Module• DC Decoupling Device

Company Name

Address

Establishment

Phone

Homepage

E-mail

enesG Co., Ltd.

8, Techno 10-ro, Yuseong-gu, Daejeon, Korea

Mar. 2002

82-42-718-5000

www.enesg.co.kr

[email protected]

Main Products • Maintenance Engineering for Turbine Hydraulic System• Turbine Hydraulic Actuator Manufacture • In-service inspection and integrity evaluation for Turbine rotor & Boiler

• Performance test, thermal performance diagnosis, measure ment for nuclear, thermal, combined cycle power plant

Company Name

Address

Establishment

Phone

Homepage

E-mail

SEHONG Corporation

SEHONG Building, 16, Tapsil-ro 58beon-gil,

Giheung-gu, Yongin-si, Gyeonggi, Korea

Oct. 1996

82-2-1670-1610

www.sehong.net

[email protected]

Main Products • excelline : Modular Wiring System.• exsaver : Automatic Receptacle Control System.

Page 52: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

100 101

Manufacture Company Introduction

Manufacture Company Introduction

Company Name

Address

Establishment

Phone

Homepage

E-mail

EHWA TECHNOLOGIES INFORMATION Co., Ltd.

746, Nonhyeon-ro, Gangnam-gu, Seoul, Korea

Jan. 1956

82-2-3440-0200

www.eti21.com

[email protected]

Main Products • Uninterrupted Power Supplies (UPS) • Transformer• Rectifier• Frequency Converter• Charge and discharge regulator

Company Name

Address

Establishment

Phone

Homepage

E-mail

Yousung Instrument & Electric Co., Ltd.

70, Aenggogae-ro, 556beon-gil,

Namdong-gu, Incheon, Korea

Aug. 1989

82-32-819-6135

www.yousung.com

[email protected]

Main Products • Digital Protection Relay• Semiconductor Solid Control Relay • Condition Monitoring system for M.Tr and GIS• Substation Automation System• Switchboards, Digital Mozaic Panel, Protection Panel

Company Name

Address

Establishment

Phone

Homepage

E-mail

WOOJIN INC

110, Dongbu-daero 970beon-gil, Hwaseong-si,

Gyeonggi-do

May. 1980

82-31-379-3114

www.woojininc.com

webmaster@woojininc,com

Main Products • RSPT• HJTC

• ICI Assembly• FRRTD

Company Name

Address

Establishment

Phone

Homepage

E-mail

YOUHO ELECTRIC IND Co., Ltd.

217, HWAHAP-RO, GWANGJEOK-MYEON,

YANGJU-SI, GYEONGGI-DO, KOREA

Jul. 1979

82-31-828-9000

www.youho.co.kr

[email protected]

Main Products • ON-Line GIS PD Diagnostic System• PD simulator for testing for GIS Partial Discharge Monitoring System

• Substation Automation Operating System• Switchgear and switchgear protection

Company Name

Address

Establishment

Phone

Homepage

E-mail

Jinwoo System Co., Ltd.

33-33 (Gasan-dong, Daeryung-Technotown

2cha, 104,107), Gasan digital 1-ro,

Geumcheon-gu, Seoul, South Korea

Jun. 1991

82-2-2109-8008

www.utpole.co.kr / www.lite-way.co.kr

[email protected]

Main Products • LITE-WAY : Continuous rows of Luminaires (Luminaires designed for end-to-end connections to form a continuous assembly)

• U.T. Pole : Metal Wireways (Telecommunication systems, Communication and LAN network Lines are separated from the Power lines by fixed or movable divider in the Unit)

Company Name

Address

Establishment

Phone

Homepage

E-mail

Cheryong Electric Co., Ltd.

628 Achasan-ro, Gwangjin-gu,

Seoul, Korea

Dec. 1986

82-2-2204-6300

www.cheryongelec.com

[email protected]

Main Products • distribution transformers, switchgears and hardware & fittings for distribution and transmission line.

Company Name

Address

Establishment

Phone

Homepage

E-mail

JEONO Co., Ltd.

641, Aegibong-ro, Tongjin-eup, Gimpo-si,

Gyeonggi-do, korea

Dec. 1979

82-31-998-8523

www.jeono.com

[email protected]

Main Products • Terminals Class-1E (Q), Non Class-1E (S)• Compression Terminals & Casting Lugs• Lightnning Protection Materials• Sleeves• Cable Ties

• Terminal Blocks• Wire Connectors• Accessory & Tools• Grounding Materials

Company Name

Address

Establishment

Phone

Homepage

E-mail

ENTEC ELECTRIC & ELECTRONIC Co., Ltd.

225-38, Choerubaek-ro, Bongdam-eup,

Hwaseong-si, GyeonggI–do, Korea

Dec. 1996

82-31–299-8400

www.entecene.co.kr

[email protected]

Main Products • Solid dielectric equipments for Power Transmission & Distribution• Solid Recloser and Gas Recloser• Load Break Switch• Pad mount Switchgear• Ring Main Unit

Page 53: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

102 103

Manufacture Company Introduction

Manufacture Company Introduction

Company Name

Address

Establishment

Phone

Homepage

E-mail

Taewoong Co.,Ltd

67,Noksansandan 27-ro, Gangseo-gu, Busan,

Korea

May. 1981

82-51-329-5000

www.taewoong.com

[email protected]

Main Products •Wind power generation : main shaft, tower flange, etc.•Oil and gas : lower housing, bop door, etc.•Industrial plant : Kiln tire, crane wheel, etc.•Nuclear and thermal power generation : tube sheet, diaphragm, etc.•Ship building and diesel engine : propeller shaft, cylinder cover, etc.

Company Name

Address

Establishment

Phone

Homepage

E-mail

Hyundai Heavy Industries Co., Ltd.

Bangeojinsunhwan-doro, Dong-gu, Ulsan,

682-792, South Korea

Dec. 1973

82-52-202-2114

www.hyundai-elec.com

[email protected]

Hyundai Heavy Industries has earned a worldwide reputation as the best business partner in the power industry by manufacturing and supplying the highest quality electric equipment, including Transformers up to 800 kV, GIS up to 800 kV, Low & Medium Voltage Switchgear, Circuit Breakers, Motors, Generators, Power Electronics, and Integrated Control & Monitoring System.

Company Name

Address

Establishment

Phone

Homepage

E-mail

KOREA CHINO CORPORATION

120, Dongbu-daero970beon-gil,

Hwaseong-si, Gyeonggi-do, Korea

Sep. 1989

82-31-379-3700

www.chinokorea.com

[email protected]

Main Products • Graphic recorder (KR2000 Series)

Company Name

Address

Establishment

Phone

Homepage

E-mail

PNC TECHNOLOGIES Co., Ltd.

62, Jeonpa-ro104beon-gil, Dongan-gu,

Anyang-si, Gyeonggi-do, Korea

Mar. 1999

82-31-452-5791

www.pnctech,co,kr

[email protected]

Main Products • Feeder Terminal Unit• Numerical Protection Relay• Digital Power meter

Company Name

Address

Establishment

Phone

Homepage

E-mail

PROCOM Systems Co., Ltd.

40-11, Techno 6-ro, Yuseong-gu,

Daejeon, Korea

Jul. 1993

82-42-253-7007

www.procom.co.kr

[email protected]

Main Products • PSDR-XU (Fault Recorder)• ProCT-1000MD (Current Transformer Tester)• PS34A (Power Transformer Tester)• ART-7 (Auxiliary Relay Tester)

Company Name

Address

Establishment

Phone

Homepage

E-mail

PESSCO Co., Ltd.

Rm.617, Busan Digital Valley, Gamjeon-Dong,

Sasang-Gu, Korea

Jan. 2002

82-51-329-7145~6

www.pessco.com

[email protected]

Main Products • Spray Vavle• Spray Tray

Company Name

Address

Establishment

Phone

Homepage

E-mail

HYOSUNG GOODSPRINGS

6F, HYOSUNG Bldg, 119, Mapo-daero,

Mapo-gu, Seoul, Korea

Oct. 1989

82-2-707-7000

www.hsgoodsprings.com

[email protected]

Main Products High Pressure, Large-sized Pumps for Thermal, Nuclear Power, Petrochemical, Refinery, Desalination Plants, Buildings and Houses

Company Name

Address

Establishment

Phone

Homepage

E-mail

PYUNGIL Co., Ltd.

9-30, Gwanak-daero, 434beon-gil,

Dongan-gu, Anyang-si, Gyeonggi-do, Korea

Sep. 1970

82-31-420-6600

www.pyungil.co.kr

[email protected]

Main Products • 25kV terminated the connection member• 25kV straight line connecting material• 25kV 600amp switch the connection member• Polymer arrester • Polymer cutout switch• instrument transformers for current transformer• Polymer Suspension Insulator • Sexual Transmission

Page 54: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

104

Manufacture Company Introduction

Company Name

Address

Establishment

Phone

Homepage

LS Cable & System Ltd.

12nd-17th Fl. LS Tower, 127 LS-ro, Dongan-gu,

Anyang-si, Gyeonggi-do, Korea

May. 1962

82-2-2189-9114

www.lscns.com

Main Products • Energy : Extra-high Voltage Cables, Overhead Wire, Distribution Cables, Submarine Cables, Bus-duct

• Telecommunication : Optical Cables, Structured Cabling System, • RF Feeder System• Industrial Cable : Industrial Specialty Cables, Industrial Devices Cables,• Automobiles Cables, Harness&Module, Tubes• Materials : Copper Rod, Magnet Wires, Aluminum

Company Name

Address

Establishment

Phone

Homepage

E-mail

LSIS Co., Ltd.

127 LS-ro, LS Tower, Anyang-si,

Gyeonggi-do, Korea

Jul. 1974

82-2-1544-2080

www.lsis.com

[email protected]

Main Products • Electric Power Solution (Low-voltage, high-voltage, relays, electric meter, transformers, gas insulated switchgear, distribution panel, bus duct system, HVDC), Automation Solution (PLC, AC Drive, PSC, HMI, Servo Motor & Drive), Convergence Solution (Smart Grid, Photovoltaic Solution, railway system, electric car component)

Company Name

Address

Establishment

Phone

Homepage

E-mail

BHI. Co., Ltd.

122, Jangback-ro, Gunbuk-myeon,

Haman-gun, Gyeongsangnam-do, Korea

Jun. 1988

82-55-585-3800

www.bhi.co.kr

[email protected]

BHI, leading power plant company, fabricates and supplies the boiler, condenser and other various BOP components such as heat exchanger and deaerator which are directly connected to the turbine and generator for coal-fired and nuclear power plant. Based on license agreement Amec Foster Wheeler, BHI is capable of designing high-quality products of PC, Oil&Gas, CFB and HRSG boiler with technology-intensive and time-proven technology. Recently, BHI was awarded with 2units of 500MW PC Boilers and is

Central Organization Leadingthe 21 Century’s Electric Power IndustryWe are fully committed to playing a key role and effective support tocope with in any challenges faced by the Korean electric power industrywhile creating new values and reinforcing customer supports.

Korea Electric AssociationWorld Best Global Association

Page 55: Products Catalog of Company Members - kea.kr · Products Catalog of Company Members ... 7 Switchgear, geargear ... gas insulated switchgear (GIS) in power stations and substations,

- KOREA ELECTRIC ASSOCIATION