Total Operation SystemTotal Operation System
Operator UI * Provision Web based UI * Manager UI+Automatic control, DR, Manager information set –up function
Management Office UI* Daily / Monthly / Site / Load electricity power usage status* Comparison electricity power usage / Timely demand electricity power status / Timely site usage / weather
Operator UI * Provision Web based UI * Manager UI+Automatic control, DR, Manager information set –up function
Management Office UI* Daily / Monthly / Site / Load electricity power usage status* Comparison electricity power usage / Timely demand electricity power status / Timely site usage / weather
Features
Function
Operator (Total Operator)
• Administrator & User management
• Total / Individual Electricity power status monitoring & Usage statistics
• DR Event Monitoring
Management Office(Administrator)
• User Management
• Monitor User’s Electricity power usage & statistics
Customer(User)
• Monitor User’s Electricity power usage & statistics
Management Office UI
Customer UI
Total Operation SystemTotal Operation System
Automatic Meter Reading SystemAutomatic Meter Reading System
Feature
Remote measurement of each household energy
consumption, without having to visit every households. By
using computer and communication technology,
AMR system automatically measure each household’s
consumption and efficiently manage energy consumption.
System MapSystem Map
CCMS(Central control and management system
I/F
DCU
Meter box & TCB
Digital water meter Digital Gas Meter
Digital Hot-water meter
Digital Heat Meter
System UISystem UI
Abroad Achievement Abroad Achievement
타워펠리스
분당파크뷰
반포삼성래미안
여의도국제금융센터
두산타워
굿모닝시티
Marina Bay Sands Hotel (Singapore)
Doosan Habico Tower (Vietnam)
Kyungnam Landmark Tower (Vietnam)
Changi Airport (Singapore) Hanjin Heavy Industries (Philippines)
Posco North An-Khan (Vietnam)
Energy Storage SystemEnergy Storage System
Drawing
Function
Production and Consumption) at the same time
- Late night electricity, pump power electricity
Isolation of producer and consumer
- Less electrical accidents
One-sided production to consumer
- Non efficient. Change of volume difficult.
Specification
SolarSolar
WindWind
WaterWater
BioBio
GeothermyGeothermy
Fuel batteryFuel battery
Hydro energyHydro energy
Coal liquefactionCoal liquefaction
Renew
New
Electricity ProductionElectricity Production The need of ESSThe need of ESS
ProProducducee
StorStoree
Storing of
produced electricity
System ConfigurationSystem Configuration
RS-485
Fire Prevention
HVACEMSPMS TCP/IP
#1 RACK
BatteryBattery
M_BMS
Battery
Battery
BatteryBattery
M_BMS
Battery
Battery
#2 RACKPCS_100KW
Power Converting SystemControl : Power, Voltage, Current
Battery Management systemMonitor and Protect of Battery
Power Management SystemControl : ESS equipments
AchievementsAchievements
SEC SMART METERSEC SMART METER
Specification
Model No. OMWH-3306W, OMWH-3406W
Electrical spec
Rated current (In): 1.5AMaximum current (Imax): 6A
The reference Voltage
CT & VT-Operated meter : 110V (Phase to Phase)CT meter (Able to cover dual voltage): 133/230V and 230/400V
Number of Elements
CT/VT-Operated meter: 3phases-3wires, 2-3 elementsCT-Operated meter: 3phases-4wires, 3-elements
Accuracy class
Active Energy: CL 0.5Reactive and apparent Energy: CL 2.0
Protocol Open Protocol (DLMS/COSEM protocol)Physical
Port
RS-485 / Optical Port Optical Port (300 baud, 9600 baud)
Function
OMWH-3306W :
CT/VT-operated meter, 3P3W, 1.5(6(A)
OMWH-3406W :
CT-operated meter, 3P4W, 1.5(6)A
* Number of TOU channels supported: at least 8 channels * The number of energy quantities to be recorded per each TOU rate. * Number of daily/Weekly/Seasons profile: at least 8 for each daily, Weekly and seasons. * Each TOU period is independently time controlled using a 24-hour clock so that registration takes place over a restricted period of time.
* Number of TOU channels supported: at least 8 channels * The number of energy quantities to be recorded per each TOU rate. * Number of daily/Weekly/Seasons profile: at least 8 for each daily, Weekly and seasons. * Each TOU period is independently time controlled using a 24-hour clock so that registration takes place over a restricted period of time.
Features
Drawing
LCD Display
KEPCO SMART METER (G-TYPE)KEPCO SMART METER (G-TYPE)
Function
Registration Technical Specifications of KEPCO
(KOREA ELECTRICITY POWER CORPORATION)
G-TYPE Electricity Meter for Active power(1.0 Class),
Reactive(2.0 Class), Apparent(1.0 Class) metering accuracy.
Specification
ClassificationModel
OMWH-12100G OMWH-34100G
Phase Wire 1P 2W 3P 4W
Rated Voltage (V) 220 220/380
Rated Current (A) 100(10) 100(10)
Class Active 1.0, Reactive 2.0,
Apparent 1.0
Active 1.0, Reactive 2.0,
Apparent 1.0
Load Control Contactor(Relay) - All in one type Contactor control signal output
Calibrating constant
(Pulse/kWh)
Active 1000 / Reactive 1000
/ Apparent 1000
Active 1000 / Reactive 1000
/ Apparent 1000
Rated Frequency (Hz) 50 / 60
Measuring Both Way (Receiving, Transmission, Active, Reactive, Apparent)
Max. demand power (time) 15minutes
Recorded channel (ch) 8-channel
Temperature (℃) -40 ~ 60℃ ℃
Battery 1,200mAh, 3.6V, Size 1/2AA
Display TN Liquid Crystal Display(LCD)
Dimension 150 (W) 160 (L) 75 (D) 194 (W) 221.5 (L) 75 (D)
Case Material Cover / Base : Polycarbonate 90%, Glass 10%
* Maximum Data of 8pcs channel is automatic saved
* Manage monthly reading data
* Save Real-time data of maximum 6,240pcs
* Changeable predetermined value of reading data of 8pcs channel +
self-diagnosis monitoring data and program change, time change
* Storage period : 5/10/15/30min selectable
* Maximum Data of 8pcs channel is automatic saved
* Manage monthly reading data
* Save Real-time data of maximum 6,240pcs
* Changeable predetermined value of reading data of 8pcs channel +
self-diagnosis monitoring data and program change, time change
* Storage period : 5/10/15/30min selectable
Features
Drawing
LCD Display
D C UD C U
Specification
Model No. DCU - 128S
Power AC 220V, 60Hz Size 130W x 144H x 47.4D
No. of connection
SINGLE TWISTED PARE ( 2 – LINE )
Speed 1200bps
Max distance 1.2 Km from DCU Communication RS-485
Max connection
128EA
Drawing
* Performing a real time data communication between 128EA household’s telemeter and CCMS which connects to DCU
* Performing a real time data communication between 128EA household’s telemeter and CCMS which connects to DCU
Features
Function
Connect 128EA household’s data by connecting each
household’s telemeter to interface unit.
2way Communication Digital Electricity Meter2way Communication Digital Electricity Meter
Specification
Model OMWH series
PowerSingle phase Two WireThree Phase Four Wire
Rated Voltage(
V)220/380V
Installation Electricity meter boxReading
point5 POINT (electricity, water, hot water, gas, heat)
Utility meter communication
DC PLC ( 2 Line )Communication
RS-485
Drawing
• Accurate energy consumption data communicating by using RS-485 communication• Acquired CL 1.0, precision electricity meter• Measuring each household’s energy consumption and transmission/receiving data, Stores data in Non-Volatile Memory• Easy to install for compact size
• Accurate energy consumption data communicating by using RS-485 communication• Acquired CL 1.0, precision electricity meter• Measuring each household’s energy consumption and transmission/receiving data, Stores data in Non-Volatile Memory• Easy to install for compact size
Features
Function
Measuring each household’s energy consumption and
transmission/receiving data in real time. Receive each
utility meter’s data and transmits consumption data to
CCMS by RS-485 communication
TRANSCEIVER (Communication Terminal Block)TRANSCEIVER (Communication Terminal Block)
Specification
Model No. OMT-12
Power AC 220V 60Hz Size 94W x 55H x 48D
Installation Electricity meter boxReading
point5 POINT (electricity, water, hot water, gas, heat)
1 ChannelDC-PLC
Utility meter communication2 Channel
RS-485Electricity meter, DCU
Drawing
• RS-485 communication with electricity meter• RS-485 communication with other TRANSCEIVER• DC-Power Lone Communication(DC-PLC) with digital utility meter
• RS-485 communication with electricity meter• RS-485 communication with other TRANSCEIVER• DC-Power Lone Communication(DC-PLC) with digital utility meter
Features
Function
Collecting energy consumption data from electricity
meter and utility meter, transmitting the data to wall pad
and DCU in real time.
Storing and transmitting transmission/receiving power
data and accumulated energy consumption data in real
time.
Digital Water MeterDigital Water Meter
Specification
Model No. OWD-SD15,SD20
Power Lithium battery (3.6V) Title Vane wheel type digital water meter
Normal flow (㎡ /h) 0.026 ~ 0.8
Maximum flow rate display
99,999,999㎥
Accuracy Q3 (2/100)Minimum
measurement unit flow
0.0001㎥
Maximum working pressure
Under 1MPaUtility meter
communicationDC PLC ( 2 Line )
Drawing
• Easy to wiring for it’s DC-Power Line Communication(2wire) • Minimize battery drain by installing Power Line Communication(PLC)• Accurate tele-meter reading, error rate is zero• LC sensor system
• Easy to wiring for it’s DC-Power Line Communication(2wire) • Minimize battery drain by installing Power Line Communication(PLC)• Accurate tele-meter reading, error rate is zero• LC sensor system
Features
Function
Measuring each household’s water consumption data.
Communicate with transceiver by DC-Power Line
Communication(DC-PLC), transmitting data to CCMS
through DCU.
13MM
Digital Heat MeterDigital Heat Meter
Specification
Model No. OCM-SD15,SD20,SD25
Power Lithium Battery (3.6V) Title Digital heat meter
Temperature range 0 ~90℃ ℃ Maximum resolution 9999,999MWh
Thermometer specification
Pt 500 Minimum resolution 0.001MWh
Maximum working pressure
Under 0.98MPa(10Bar)Utility meter
communication systemDC PLC ( 2 Line )
Drawing
• Minimize installation space, good appearance• Minimize battery drain by installing Power Line Communication(PLC)• May playback data when the meter power is off for its embedded memory element• Durable, long life time• Easy to manage for warning sign on display
• Minimize installation space, good appearance• Minimize battery drain by installing Power Line Communication(PLC)• May playback data when the meter power is off for its embedded memory element• Durable, long life time• Easy to manage for warning sign on display
Features
Function
Measuring each household’s heat consumption data.
Communicate with transceiver by DC-Power Line
Communication(DC-PLC), transmitting data to CCMS
through DCU.
13MM
Digital Gas MeterDigital Gas Meter
Specification
Model No. OGA-DG1.6,DG2.5,DG4.0
Power Lithium battery (3.6V) Title Digital diaphragm gas meter
Maximum flow rate Qmax
2.5 ㎥ /hMinimum flow rate
Qmin0.016 ㎥ /h
Maximum resolution 9999,999㎥ Minimum resolution 0.001MWh
Maximum working pressure
Under 10 KPa Utility meter
communication systemDC PLC ( 2 Line )
Drawing
• Acquired Korea type examination certification which have equivalent standard with OIML.• Shrinkage change which caused by temperature change(-25~55 ) is small, ℃ stabilize pressure difference curve by adopting a round metering diaphragm • Stabilize flow path, decrease pressure loss and gas pulsation• Having a large metrological range, may measure accurately the flow-rate from Qmin to Qmax• Accurate real time telemetry, error rate is zero• Preventing one side wear of valve.
• Acquired Korea type examination certification which have equivalent standard with OIML.• Shrinkage change which caused by temperature change(-25~55 ) is small, ℃ stabilize pressure difference curve by adopting a round metering diaphragm • Stabilize flow path, decrease pressure loss and gas pulsation• Having a large metrological range, may measure accurately the flow-rate from Qmin to Qmax• Accurate real time telemetry, error rate is zero• Preventing one side wear of valve.
Features
Function
Reading data with DC-PLC, communicating with each
household’s communication module with RS-485.
Transmitting each household’s energy consumption data
to CCMS through DCU.