Project Documentation Page 1 of 18 05/2020 Project Documentation Gebäude-Dokumentation 1 Abstract / Zusammenfassung Childcare centre in Torrens Australia 1.1 Data of building / Gebäudedaten Year of construction/ Baujahr 2018 Space heating / Heizwärmebedarf 15 kWh/(m²a) U-value external wall/ U-Wert Außenwand 0.263 W/(m²K) U-value basement ceiling/ U-Wert Kellerdecke 0.469 W/(m²K) Primary Energy Renewable (PER) / Erneuerbare Primärenergie (PER) 29 kWh/(m²a) U-value roof/ U-Wert Dach 0.177 W/(m²K) Generation of renewable energy / Erzeugung erneuerb. Energie 143 kWh/(m²a) U-value window/ U-Wert Fenster 0.91 W/(m²K) Non-renewable Primary Energy (PE) / Nicht erneuerbare Primärenergie (PE) 64 kWh/(m²a)

Upload: others

Post on 21-May-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 1 of 18 05/2020

Project Documentation Gebäude-Dokumentation

1 Abstract / Zusammenfassung

Childcare centre in Torrens Australia

1.1 Data of building / Gebäudedaten

Year of construction/ Baujahr

2018 Space heating / Heizwärmebedarf

15 kWh/(m²a) U-value external wall/

U-Wert Außenwand 0.263 W/(m²K)

U-value basement ceiling/ U-Wert Kellerdecke

0.469 W/(m²K) Primary Energy Renewable (PER) / Erneuerbare Primärenergie (PER) 29 kWh/(m²a)

U-value roof/ U-Wert Dach

0.177 W/(m²K) Generation of renewable energy / Erzeugung erneuerb. Energie

143 kWh/(m²a)

U-value window/ U-Wert Fenster

0.91 W/(m²K) Non-renewable Primary Energy (PE) / Nicht erneuerbare Primärenergie (PE)

64 kWh/(m²a)

Page 2: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 2 of 18 05/2020

Heat recovery/ Wärmerückgewinnung

77 % Pressure test n50 / Drucktest n50

0.6 h-1

Special features/ Besonderheiten Solar PV array, heat pump domestic hot water, rainwater utilisation

Page 3: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 3 of 18 05/2020

1.2 Project Description

Torrens Early Learning - Passive House

Torrens Early Learning is a long-day-care facility which provides early education and care for 89 children aged from 6 weeks to 6 years, and has a staffing element of around 20 carers/teachers /administration staff.

The facility consists of 2 separate buildings, (both 2 storey) linked by a large external deck and playgrounds and front entrance.

The first building has administration, commercial kitchen, dining rooms and a baby’s nursery space – this building was a re-adaption of the existing building’s footprint. The re-adaption reused the slab and services, retained brick fences, and boundaries, and rebuilt and re-developed the space. The building was built to the Passive House standard, but did not meet the final airtight criteria.

The second building is a certified Passive-House building – certified as Premium. The building was developed for solar performance – to face north, allow a roofline for maximum solar panels, to allow natural light into all learning spaces, and mobility access for children to all spaces and playgrounds. Careful attention was paid to windows and the distribution of light into classrooms, and importantly solar heat gain in winter, and the rejection of such heat in summer. The building consists of 6 large classrooms, and 3 bathrooms.

Page 4: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 4 of 18 05/2020

1.3 Responsible project participants / Verantwortliche Projektbeteiligte

Architect/ Entwurfsverfasser

Christie Hartfiel Architectural Design / Can PLAY / VRD Design

Implementation planning/ Ausführungsplanung

Christie Hartfiel Architectural Design / Can PLAY / VRD Design

Building systems/ Haustechnik

Rudds Consulting Engineers

Structural engineering/ Baustatik

Tim Gibney & Associates

Building physics/ Bauphysik

H3Space

Passive House project planning/ Passivhaus-Projektierung

H3Space

Construction management/ Bauleitung

Can PLAY

Certifying body/ Zertifizierungsstelle

Detail Green

Certification ID/ Zertifizierungs ID

Project-ID (www.passivehouse-database.org)

Projekt-ID (www.passivehouse-database .org) 6326

Author of project documentation / Verfasser der Gebäude-Dokumentation

Harley Truong H3Space

Date, Signature/ Datum, Unterschrift

8 May 2020

Page 5: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 5 of 18 05/2020

2 Views

North west elevation

North elevation

Page 6: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 6 of 18 05/2020

East elevation

South elevation

Page 7: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 7 of 18 05/2020

Playground

Classroom

Page 8: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 8 of 18 05/2020

3 Section drawings

Cross section

The thermal envelope consists of prefabricated Carbonlite panels for walls and roof all sitting on an insulated concrete slab. The mid floor is made from Cross Laminated Timber (CLT)

Detailed cross section

GROUND FLOOR

643050

BASEMENT

640000

UPPER CEILING

648580

1

A32

2030

5025

50

85 m²RESOURCE

87 m²

PRESCHOOLX 22

TIMBER PANEL ROOF TO ENGINEER'S DETAILS,COLORBOND 'MONUMENT' STANDING SEAMCLADDING

TIMBER PANEL FLOORTO ENGINEER'SDETAILS, FYRCHEKCLADDING TOUNDERSIDE AS PERFIRE ENGINEER'SDETAILS

DOUBLE BRICKWALLS AND CONCRETESLAB FLOOR TOENGINEER'S DETAILS,INSULATEDINTERNALLY.

400500

JOINERY TO YOLK DETAIL

JOINERY TO YOLK DETAIL

600270

ROLLER SHUTTER 5

9

1

2

SHEET TITLE:

CLIENT:

LOCATION:

PROJECT: SHEET No:

AREAS:

SCALE: JOB No:

DATE:

&1�016�5%#.'�1((�2.#0��94+66'0&+/'05+105�9+..�6#-'�24'%'&'0%'�

#..�6+/$'4�(4#/+0)�#0&�%105647%6+10�/756%1/2.;�9+6*�#5����������6*'�0#6+10#.�6+/$'4�(4#/+0)�%1&'�

#..�4�%�(116+0)5�#0&�%10%4'6'�5.#$5�#4'57$,'%6'&�61�#�51+.�%.#55+(+%#6+10�#0&/756�%1/2.;�9+6*�#5�����������4'5+&'06+#.�5.#$5��(116+0)�%1&'��

.+06'.5�61�64755�/#07(#%674'45�%*#46�&'5+)0�9+0&�.1#&+0)����O�U6'44#+0�%#6')14;���

#..�$7+.&+0)�914-�/756�$'�+0�#%%14&#0%'9+6*�6*'�0#6+10#.�%105647%6+10�%1&'�%1/2.;�9+6*�#..�4'8'.#06�#5�%1&'5�#0&#�%6��5722.'/'06�#5�4'37+4'&��

#0;�&+5%4'2#0%+'5�/756�$'�&+5%755'&9+6*�6*'�&4#(65/#0

ABN 53 008 609 925 PH: (02) 6101 5917 MOB: 0414 488 420

DESIGN

10

VERSICLAD 'MONOLITH' ROOFING & STEEL PERGOLA

2360

2412

SECTION XX

ORIGINAL DESIGN BY:

AMENDMENTS: 16-02-181. REMOVE STAIRS FROM DECKS2. EXTEND DECK3. INTERNAL LAYOUT CHANGED4. CHANGEROOM LAYOUT ALTERED TO ADD SHOWER5. TIMBER GATES CHANGED TO ROLLER SHUTTER6. EXTERNAL DOOR OF WASTE ENCLOSURE REMOVED7. BRICKS & COLOURBOND CHANGED TO ALUCOIL8. COLOUR OF MODWOOD CLADDING CHANGED TO GREY9. BALUSTRADES CHANGED TO BLACK FRAMED GLASS10. NEW VERSICLAD & SAIL ROOF OVER DECK11. NEW TERRACES & DECK TO PLAYSPACE12. COLOURBOND CLADDING CHANGED TO BRICKWORK13. NO SUB-FLOOR DOOR14. NEW SHADE SAILS15. ALTERED FENCE

2016

1206

-TO

RR

ENS-

ADD

ITIO

N-S

ECTI

ON

ATBA

SEM

ENT

ATFY

RC

HEC

K

boun

dary

sout

hw

all

EQ6434_SPEC

EQ6434_SPEC

EQ6434_SPEC

EQ6434_SPEC

FYRCHECK 16MM

CSR Gyprock Fire Mastic

lvl raftersOSB 18mm

Alu roller shutters

900

under fascia (by others)

cladding + top hat by others

13

13

2x 13mm fyrcheck - noggins(in between rafters)

2x 13mm fyrchek

CSR Gyprock Fire Mastic

40

overlap13

13

1616

160mm LVL

Brick lintel

2005016

1214055

45 14012

13

13

900

Page 9: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 9 of 18 05/2020

4 Floorplan

The ground floor has four classrooms and two bathrooms. The lower ground has a similar layout with two classrooms and single bathroom. Access to each of the classrooms is through an external entry door. There are no internal stairwells.

Ground floor

Lower ground floor

63 m²

TODDLERSX 16

87 m²

PRESCHOOLX 22

ABCDEFGHIJKLM

270

11430

30275

3200 600 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400

62 m²

INFANTSX 16

643050

900270600

9960

600270

3000

N

81 m²

EARLYLEARNERS

4930

5030

11700

54

600

100

4930

850355850475800800800

12 m²WC 2

12 m²WC 1

850

600

600

600

P

O

WASHER

WASHER

WASHER

WASHER

1

3 3

2

SHEET TITLE:

CLIENT:

LOCATION:

PROJECT: SHEET No:

AREAS:

SCALE: JOB No:

DATE:

ABN 53 008 609 925 PH: (02) 6101 5917 MOB: 0414 488 420

DESIGN

Q

ORIGINAL DESIGN BY:

�����������+0&+%#6+8'�.1%#6+105�1(#..�$7+.&+0)�914-�/756�%1/2.;�9+6*�6*'�

��������9*'4'�5*190��*#4&�9+4'&�61�#5�����

0�%�%�#0&�#..�4'.'8#06�#5�%1&'5�

&+/'05+105�9+..�6#-'�24'%'&'0%'&1�016�5%#.'�1((�2.#0��94+66'0

/#+06#+0�%#8+6;�%105647%6+10�

�����������4'(4+)'4#614��16*'4�#22.+#0%'5�(4

��������5/1-'�#.#4/5�/756�%1/2.;�9+6*������������������1(�6*'�0�%�%��#5������+056#..'&�AMENDMENTS: 16-02-18

1. REMOVE STAIRS FROM DECKS2. EXTEND DECK3. INTERNAL LAYOUT CHANGED4. CHANGEROOM LAYOUT ALTERED TO ADD SHOWER

5. TIMBER GATES CHANGED TO ROLLER SHUTTER6. EXTERNAL DOOR OF WASTE ENCLOSURE REMOVED7. BRICK SKIN CHANGED TO ALUCOIL8. COLOUR OF MODWOOD CLADDING CHANGED TO GREY9. BALUSTRADES CHANGED TO BLACK FRAMED GLASS

10. NEW VERSICLAD & SAIL ROOF OVER DECK11. NEW TERRACES & DECK TO PLAYSPACE12. COLOURBOND CLADDING CHANGED TO BRICKWORK13. NO SUB-FLOOR DOOR14. NEW SHADE SAILS15. ALTERED FENCE

11

641

250

639500

639

750

6400

00

6405

00

640

750

6410

00

6412

50

641

500

639750

6400

00

640250

640500

640750

6410

00

641

250

ABCDEFGHIJKLM

85 m²RESOURCE

79 m²STORAGE

240024002400240024002400240024002400240024002400600

270

1056

060

027

090

0

16430460

XX

N

1170

0

600

600

4930

800

447

900

1400

34 m²PLANT

ROLLER SHUTTER

ADD WINDOWS

ADD WINDOW

ADD WC

4930

5630

UNDERCROFT WITHSUSPENDED TIMBER FLOORABOVE. STEEL PIERS TOENGINEER'S DETAIL 17

00

640000

640000

640000

641800

641800

PAINTED BLOCKRETAININGWALL

10 m²WC 3

TIMBER SCREEN

11501001150

2701860270

600

Q

P

O

WASHER

1

3

2

5

SHEET TITLE:

CLIENT:

LOCATION:

PROJECT:

SCALE:

AREAS:

SHEET No:

JOB No:

DATE:

ABN 53 008 609 925 PH: (02) 6101 5917 MOB: 0414 488 420

DESIGN

0�%�%�#0&�#..�4'.'8#06�#5�%1&'5�

&+/'05+105�9+..�6#-'�24'%'&'0%'&1�016�5%#.'�1((�2.#0��94+66'0

/#+06#+0�%#8+6;�%105647%6+10������������+0&+%#6+8'�.1%#6+105�1(

#..�$7+.&+0)�914-�/756�%1/2.;�9+6*�6*'������������4'(4+)'4#614��16*'4�#22.+#0%'5�(4

��������9*'4'�5*190��*#4&�9+4'&�61�#5�����

��������5/1-'�#.#4/5�/756�%1/2.;�9+6*������������������1(�6*'�0�%�%��#5������+056#..'&�

5*4

4

ORIGINAL DESIGN BY:

11

AMENDMENTS: 16-02-181. REMOVE STAIRS FROM DECKS2. EXTEND DECK3. INTERNAL LAYOUT CHANGED4. CHANGEROOM LAYOUT ALTERED TO ADD SHOWER

5. TIMBER GATES CHANGED TO ROLLER SHUTTER6. EXTERNAL DOOR OF WASTE ENCLOSURE REMOVED7. BRICK SKIN CHANGED TO ALUCOIL8. COLOUR OF MODWOOD CLADDING CHANGED TO GREY9. BALUSTRADES CHANGED TO BLACK FRAMED GLASS

10. NEW VERSICLAD & SAIL ROOF OVER DECK11. NEW TERRACES & DECK TO PLAYSPACE12. COLOURBOND CLADDING CHANGED TO BRICKWORK13. NO SUB-FLOOR DOOR14. NEW SHADE SAILS15. ALTERED FENCE

Page 10: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 10 of 18 05/2020

5 Construction details

5.1 Floor slab/basement ceiling

Part of the building has a concrete slab floor that is insulated above with 50mm Phenolic foam (Lambda 0.020 W/mK). The other part of the building has a timber suspended floor insulated with 240mm of fiberglass insulation (Lambda 0.043 W/mK).

Page 11: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 11 of 18 05/2020

5.2 Exterior walls

The walls are timber framed and insulated with 140mm of fiberglass batts (Lambda 0.035 W/mK).

Page 12: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 12 of 18 05/2020

5.3 Roof

The roof is made from timber rafters and insulated with 240mm of fiberglass batts (Lambda 0.043 W/mK). Above, it is lined with OSB, a weathertight membrane and then counter battens, battens and metal roofing.

Page 13: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 13 of 18 05/2020

5.4 Windows

The Windows and doors are Neuffer brand timber – aluminium framed, made of Eucalyptus and have an average Uf value of 1.03 W/m2K. The glazing is triple glazed Argon filled with low E coatings and laminated glass where there is the possibility of human impact. The average Ug is 0.60 W/m2K and g value 0.54. Barrier free thresholds were used in the bathrooms for wheelchair access.

EQ6434_SPEC

EQ6434_SPEC

VB 401VB 401

1100

1000

400

21/22/23 09/10 35 25

2012

1208

-Alte

ratio

n-G

roun

dflo

or-V

ertic

alse

ctio

n

Idealu78

NET

nachaußen

öffnend

Page 14: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 14 of 18 05/2020

6 Airtightness

Pro Clima Intello airtight membranes were used on the walls and ceilings for airtightness. These were taped to the windows, doors, and junctions with matching airtight tapes. Penetrations were sealed with grommets.

The building achieved an airtightness test result of 0.6 ACHn50. Main leakage areas were around penetrations for data cabling.

Page 15: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 15 of 18 05/2020

7 Ventilation systems

Three SystemAir heat recovery ventilation machines are used to service the building. The heat recovery efficiency is 77% and electrical efficiency is 0.22 Wh/m3. Fresh air is delivered to the classrooms and extracted in the bathrooms. Air is delivered via rigid metal ducting that is insulated in some areas with fiberglass batts.

Page 16: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 16 of 18 05/2020

8 Heating and cooling systems

Each classroom has an average area of 83m2 and is heated and cooled with its own reverse cycle air sourced heat pump with a capacity of 5 kW.

Page 17: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 17 of 18 05/2020

9 PHPP results

The project is the first of its kind to achieve the Passive House Premium certification in Australia owing to its very low energy usage and very large 30kW solar PV array.

Passive House VerificationPhoto or Drawing Building:

Street:Postcode/City: 2607

Province/Country:Building type:

Climate data set: AU0003a-Canberra

Climate zone: 4: Warm-temperate Altitude of location: 640 m

Home owner / Client:

Street:Postcode/City:

Province/Country:

Architecture: Mechanical engineer:

Street: Street:Postcode/City: Postcode/City: 2609

Province/Country: Province/Country:

Energy consultancy: Certification:

Street: Street:Postcode/City: 2606 Postcode/City: 3747

Province/Country: Province/Country:

Year of construction: 2017 Interior temperature winter [°C]: 20.0 Interior temp. summer [°C]: 25.0

No. of dwelling units: 1 Internal heat gains (IHG) heating case [W/m2]: 2.8 IHG cooling case [W/m²]: 2.8

No. of occupants: 50.0 Specific capacity [Wh/K per m² TFA]: 60 Mechanical cooling: x

Specific building characteristics with reference to the treated floor area

Treated floor area m² 485.8 Criteria Fullfilled?2

Space heating Heating demand kWh/(m²a) 15.4 ≤ 15 -

Heating load W/m² 12 ≤ - 10

Space cooling Cooling & dehum. demand kWh/(m²a) 1 ≤ 15 15

Cooling load W/m² 4 ≤ - 11

Frequency of overheating (> 25 °C) % - ≤ - -Frequency of excessively high humidity (> 12 g/kg) % 0 ≤ 10 yes

Airtightness Pressurization test result n50 1/h 0.6 ≤ 0.6 yes

PE demand kWh/(m²a) 54 ≤ - -

PER demand kWh/(m²a) 24 ≤ 30 24

kWh/(m²a) 143 ≥ 120 111

2 Empty field: Data missing; '-': No requirement

Non-renewable Primary Energy (PE)

Primary Energy Renewable (PER) yesGeneration of renewable

energy (in relation to pro-jected building footprint area)

AU-Australia

AU-AustraliaCanberra

Rudds Consulting Engineers

5 Bodalla Place Fyshwick

Detail Green

18 Fletcher Road

Beechworth

Victoria

10B Anderson Street Chifley

Canberra

Australian Capital Territory

Torrens Childcare - New building

1 Torrens Place Torrens

Canberra

Australian Capital Territory

Majura Park Childcare Pty Ltd

AU-AustraliaChildcare centre

Christie Hartfiel Architectural Design

Australian Capital Territory

Harley Truong H3space

AU-Australia

yes

yes

Alternative criteria

AU-Australia

AU-Australia

Australian Capital Territory

Page 18: Project Documentation Gebäude-Dokumentation€¦ · The building was built to the Passive House standard, but did not meet the final airtight criteria. The second building is a certified

Project Documentation Page 18 of 18 05/2020

10 Build cost

The construction cost was 2050 Euro/m2 of Treated Floor Area and that included the outdoor play area, shading devices and landscaping.

11 Experience

Some observations after the owner occupied the site for over 12 months:

“Working at Torrens is so comfortable, we rarely need to use artificial heating or cooling, and the constant temperature and quietness of the building (no external noise, no mechanical noise) makes for a relaxing work environment. The building feels fresh and the air is clean – even during poor weather – like the January smoky bushfire events when Canberra had the worst air quality in the world. “

“My other buildings cost me 9,000 Euro a year in electricity – whilst Torrens is only 21 Euro – and that is mostly from the administration fees for being connected to the electricity grid.”