project - electrika€¦ · all marked emergency escape routes, to be measured down the centre line...
TRANSCRIPT
430
Project Lakes College - Workington, UK
Encore LED p444
Eagle LED p448
Emergency431
www.anselluk.comwww.anselluk.com
Emergency
IP65 Bulkheads
50435 50444
50448 50449
Exit Boxes
Suspended Edge IP65 Surface Edge
432
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
50460
Panel Pod Emergency
5045450451
Twin Spots LED Emergency Downlights
433
DeliverDeliverDesigned to
DeliverDeliverDesigned to
434
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
• Small and unobtrusive LED bulkhead• Supplied with self-adhesive
legend• Optic design provides
optimum performance for escape route lighting
• Side and rear cable entries• Screwless gear tray for
ease of installation• Viewing distance 17 metres
Swift LED BulkheadSupplied c/w Legend and Integral Driver
Accessory
210
100
40
LED Information
Total (W) 3WLumens DeliveredEmergency Mode 69lmStandard Mode 163lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
Code Lamp Description
ASWTLED/3M LED 3W Maintained / Non-Maintained
ASBP/1 3.6V 600mAh Ni-Cd Replacement Battery
3YR
IP65
Mounting Height (M)
2.546
2.352.242.24
67.55.9
1.981.981.98
66
5.79
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
1.481.2-
5.94-
1.480.72
-
5.84.5-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself.
** 0.5 lux minimum must be used for all areas larger than 60m2, the minimum value is to be measured across the area excluding 0.5m border around edge of room.
*** Explanation of terms; Transverse – wall -
distance to wall from to side of fitting,
Transverse – transverse - side to side spacing,
Axial – wall - distance to wall from end of
fitting, Axial – axial - end to end spacing.
2YR435
www.anselluk.comwww.anselluk.com
• Ultra-slimprofileLEDpolycarbonate bulkhead
• Supplied with self-adhesive legend
• 20mm side and rear cable entries
• Hinged screwless gear tray for ease of installation
• Viewing distance 18 metres
352
110
64
AGLED/KITWith Guardian Installed
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Guardian LED BulkheadSupplied c/w Legend and Integral Driver
Code Lamp Description
AGLED/3M LED 3W Maintained / Non-Maintained
AGLED/KIT Semi-Recessing Kit - White
ASBP/2 3.6V 1500mAh Replacement Ni-Cd Battery
Accessories
Mounting Height (M)
2.546
33.83.8
7.588
33.83.8
7.588
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
1.71.3-
5.75.6-
2.93-
65-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
3YR
LED Information
Total (W) 3WLumens DeliveredEmergency Mode 144lmStandard Mode 160lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
2YR436
Project - Lakes CollegeCumbria, UK
437
www.anselluk.comwww.anselluk.com
Kite LED Emergency BulkheadSupplied with Legend and Integral Driver
270
120
45
• Modernultra-slimprofileIP65 LED polycarbonate bulkhead
• Self-test as standard• Aesthetically designed for
modern appearance• Supplied with self-
adhesive legend• 20mm side and rear cable
entries• Hinged screwless gear
tray for ease of installation• Viewing distance 20
metres
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Mounting Height (M)
2.546
2.12.42.4
677
2.12.42.4
677
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.54-
1.51.3-
5.55-
1.31.4-
5.56-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
Code Lamp Description
AKTLED/3M/ST LED 4W Maintained / Non-Maintained
ASBP/1 3.6V 600mAh Ni-Cd Replacement Battery
Self-Test
Accessory
3YR ST
LED Information
Total (W) 4WLumens DeliveredEmergency Mode 79lmStandard Mode 182lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
2YR438
439
www.anselluk.comwww.anselluk.com
Centurion LED Bulkhead Supplied c/w Legend and Integral Driver
• High lumen performance LED polycarbonate bulkhead for increased spacings
• Supplied with self-adhesive legend
• Self-test as standard• Outperforms 8W T5 and
exceeds performance of Guardian by 56%
• 20mm conduit entry positions and rear teminal box entry
• Hinged screwless gear tray for ease of installation
• Viewing distance 18 metres
• 50,000 hours average lifetime
3YR ST
Self-Test
Accessory
Code Lamp Description
ACELED/3M/ST LED 6W Maintained / Non-Maintained
ASBP/2 3.6V 1500mAh Ni-Cd Replacement Battery
Mounting Height (M)
2.546
2.53.53.6
7.59
9.5
2.53.53.6
7.59
9.5
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
1.72-
78.5-
22.5-
6.88-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
352
6411
0
LED Information
Total (W) 6WLumens DeliveredEmergency Mode 151lmStandard Mode 254lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
2YR440
Project - Simply GymCwmbran, UK
441
www.anselluk.comwww.anselluk.com
Osprey High Rack LED BulkheadSupplied c/w Integral Driver
•ModernslimprofileIP65LED polycarbonatebulkhead• Compact high polishedreflectordesigntoproviderequired light level fromhigh mounting heights• High performance LED’sand optical performanceallows increased spacingratios• Cold store optionincorporates an intelligentintegral heat managementsystem to operate in coldstore applications down to-30°C• Self-test as standard• Aesthetically designed formodern appearance• 20mm side and rear cableentries
3YR ST
Mounting Height (M)
1015
--
--
51.2
2015.5
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
LED Information
IP65
Cold Store
Accessories
Code Lamp Description
AOSLED/3M/ST LED 9W Maintained / Non-Maintained
AOSLED/3M/CS LED 22W Maintained / Non-Maintained
ASBP/15 4.8V 4Ah Ni-Cd Replacement Battery
ASBP/16 4.8V 4Ah Ni-Cd Replacement Battery (for use with Cold Store fitting)
Total (W) 9W 22WLumens DeliveredEmergency Mode 380lmStandard Mode 438lmLumens Delivered Cold StoreEmergency Mode 383lmStandard Mode 554lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°Cold Store -30C° to 5C°
AOSLED/3M
Mounting Height (M)
1015
5.25
14.517
5.25
1822
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum)**
Axial to Wall
Axial to Axial
***
AOSLED/3M
330
135
69
2YR442
57
Quick and easy installation
Self-Test as standard
Maintenance free
Betterspacingratioforlessfittings
Osprey LEDHigh Rack Bulkhead vs. Traditional Halogen Twin SpotWarehouse racking aisle scheme (15 metre ceiling height and 2 metre aisle width)
Osprey LED 9W5 fittings to reach required lux level
Halogen Twinspot 2x20W7 fittings to reach required lux level
443
www.anselluk.comwww.anselluk.com
Standard
Self-Test
Accessory
AENLED/3M/W
AENLED/3M/SG
Code Lamp Description
AENLED/3M/W LED 2.6W Maintained/Non-Maintained - White
AENLED/3M/SG LED 2.6W Maintained/Non-Maintained - Silver Grey
AENLED/3M/W/ST LED 2.6W Maintained/Non-Maintained - White
ASBP/2 3.6V 1500mAh Ni-Cd Replacement Battery
• Ultra slim modern LED exit sign
• Self-test option• Neat picture frame
appearance compared to conventionalfluorescentexit signs
• Supplied with all legend options - arrow down, arrow up and arrow
left/right• Viewing distance 29
metres
LED Information
Total (W) 2.6WLumens DeliveredEmergency mode 29lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
316
196
36.5
Encore LED Exit SignSupplied c/w Legends and Integral Driver
3YR ST
IP20
2YR444
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Project - Harveys RestaurantRhuddlan, UK
445
www.anselluk.comwww.anselluk.com
• White steel LED exit box sign with legend
• Larger dimensions enableseasyretrofitreplacement of fluorescentproducts
• Viewing distance 37 metres
375 60
185
Watchman LED Exit SignSupplied c/w Legend and Integral Driver
Code Lamp Description
AWLED/3M LED 3W Maintained / Non-Maintained
AG8/L/AD Legend - Arrow Down
AG8/L/AR Legend - Arrow Right
AG8/L/AL Legend - Arrow Left
AG8/L/AU Legend - Arrow Up
ASBP/3 3.6V 1800mAh Ni-Cd Replacement Battery
Legends
Battery
3YR
LED Information
Total (W) 3WLumens DeliveredEmergency mode 48lmCCT 6000KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP20
2YR446
Project - The Liquor StoreManchester, UK
447
www.anselluk.comwww.anselluk.com
Eagle 3-In-1 LED Exit SignSupplied c/w Integral Driver and Legend
3YR ST • Modern, slim, 3-In-1 LED Exit Sign
• Self-test option• Onefittingthatenables
choice of three different mounting options :- suspension, recessed or side arm wall mounting
• Viewing distance 25 Metres
364 86
48.5
45
32948
45
152
70
Semi Recessed
Suspended
Side Arm Wall Mounted
323
AE3LED/3M/SISemi Recessed
AE3LED/3M/WSuspended
AE3LED/3M/WSide Arm Wall Mounted
Standard
Self-Test
Legends
Battery
Code Lamp Description
AE3LED/3M/W LED 2.5W Maintained/Non-Maintained - White
AE3LED/3M/SI LED 2.5W Maintained/Non-Maintained - Silver
AE3LED/3M/W/ST LED 2.5W Maintained/Non-Maintained - White
AE3LED/ALAR Double Sided Legend - Arrow Left and Right
AE3LED/L/AD Double Sided Legend - Arrow Down
AE3LED/L/AU Double Sided Legend - Arrow Up
ASBP/4 3.6V 800mAh Replacement Ni-Cd Battery
LED Information
Total (W) 2.5WLumens DeliveredEmergency mode 21lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP20
2YR448
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
336 130
8310
160
51
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
• Compact high performance IP65 polycarbonate surface emergency luminaire
• Self-test as standard• Optional hanging blade
legends (supplied with self-adhesive legend as standard) for enhanced appearance
• Aesthetically designed for modern appearance
• 20mm side and rear cable entries
• High output LED performance and distribution allows maximum spacing providing reduced cost
• Viewing distance 25 metres
Harrier LED IP65 Blade Exit SignSupplied c/w Self-Adhesive Legend (Optional Blade Legend ordered separately)
3YRST
Self-Test
Legends
Battery
Code Lamp Description
AHARLED/3M/ST LED 6W Maintained/Non-Maintained
AHARLED/ALAR Harrier LED Double Sided Legend - Arrow Left and Right
AHARLED/L/AD Harrier LED Double Sided Legend - Arrow Down
AHARLED/L/AU Harrier LED Double Sided Legend - Arrow Up
ASBP/5 7.2V 1500mAh Ni-Cd Replacement Battery
LED Information
Total (W) 6WLumens DeliveredEmergency Mode 142lmStandard Mode 299lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
2YR449
Project - The Liquor StoreManchester, UK
450
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
• Self-test Twin LED emergencyfloodlightforindustrial applications
• Robust white moulded enclosure
• Exceeds performance of 2x20W halogen equivalent
• Moulded polycarbonate heads
300 70
290
LED Information
Total (W) 5WLumens Delivered Emergency Mode 440lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65 Owl LED Twin SpotSupplied c/w Integral Driver
3YRST
Self-Test
Battery
Code Lamp Description
ATSLED/3NM/IP65/ST LED 5W Non-Maintained
ASBP/6 3.6V 6Ah Ni-Cd Replacement Battery
IP65
2YR451
www.anselluk.comwww.anselluk.com
Code Lamp Description
ATSLED/3NM LED 3W Non-Maintained
ASBP/7 3.6V 4Ah Ni-Cd Replacement Battery
LED Twin SpotSupplied c/w Integral Driver
3YR
• Twin LED emergency floodlightingforindustrialapplications
• Exceeds performance of 2x20W halogen equivalent
• Robust metal enclosure in an opal colour
• Moulded polycarbonate heads
IP20
Battery
310
113
277
LED Information
Total (W) 3WLumens DeliveredEmergency Mode 198lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
2YR452
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Condor LED Twin SpotSupplied c/w Integral Driver
3YR
• Sleek modern polycarbonate moulded decorative twin spot
• Individual adjustable LED array’s allowing the end user to aim output into the desired location
• Decorative design suitable for retail application
• Self-test as standard
IP20
ST
Code Lamp Description
ACTSLED/W/3NM LED 4W - White
ACTSLED/B/3NM LED 4W - Black
ASBP/6 3.6V 6Ah Ni-Cd Replacement Battery
LED Information
Total (W) 4WLumens DeliveredEmergency ModeACTSLED/W/3NM 368lmACTSLED/B/3NM 361lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
300
199
55
ACTSLED/W/3NM
ACTSLED/B/3NM
2YR453
www.anselluk.comwww.anselluk.com
Signal LED Emergency DownlightSupplied c/w Remote Driver and Battery Pack
3YR • Economic and compact LEDNon-Maintainedfixed
downlight• White and black powder
coatpaintfinish• LED combines power and
green charge indicator• 3 hour emergency output
34
33
Ø45
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
IP20
Accessory
Code Lamp Description
ASLED/3NM LED 1.5W Non-Maintained
ASLED/3NM/B LED 1.5W Non-Maintained - Black
ASBP/8 3.6V 2Ah Ni-Cd Replacement Battery
ASLED/3NM
ASLED/3NM/B
LED Information
Total (Watts) 1.5WLumens Delivered Emergency ModeASLED/3NM 137lmASLED/3NM/B 107lmBeam Angle ASLED/3NM 128°ASLED/3NM/B 115°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0°C to 45°C
Mounting Height (M)
2.54
2.54
33
2.72.6
8.597
7.5
33
2.72.6
8.597
7.5
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
ASLED/3NM
ASLED/3NM/B
Mounting Height (M)
2.546
2.546
3.63.63.6333
7.510.5116.39
10.5
3.63.63.6333
7.510.5116.39
10.5
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum)**
Axial to Wall
Axial to Axial
***
ASLED/3NM
ASLED/3NM/B
2YR454
Project - The Liquor StoreManchester, UK
455
www.anselluk.comwww.anselluk.com
Beacon LED Emergency Adjustable DownlightSupplied c/w Remote Driver and Battery Pack
3YR • LED Non-Maintained adjustable die-cast
aluminium downlight• 3 hour emergency output• Power and green charge
LED are discreetly incorporated within the head
• 22° beam angle
Ø78
52
60
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Accessory
Code Lamp Description
ABLED/3NM LED 5W Non-Maintained
ASBP/9 3.6V 4.5Ah Ni-Cd Replacement Battery
Total (Watts) 5WLumens DeliveredEmergency Mode 248lmBeam Angle 22°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0°C to 45°C
LED Information
IP20
Mounting Height (M)
2.546
2.252.53
5.77.18.25
2.252.53
5.77.18.25
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
22.5-
5.256.5-
22.5-
5.256.5-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
2YR456
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Raven LED Emergency DownlightSupplied c/w Integral Driver and Battery Pack
3YRST
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
95
• Recessed Self-test emergency downlight
with self-contained inverter and battery pack• Integral components forfast-fitinstallation• Option of escape route or open area models• High performance optic design• Pre-wired with 150mm
rubber insulated cable for ease of installation
• Up to 15 metres spacing between luminaires
Ø110
109
Code Lamp Description
ARALED/ER/3NM/ST LED 3W Non-Maintained - Escape Route
ARALED/OA/3NM/ST LED 3W Non-Maintained - Open Area
ASBP/14 3.2V Lithium Iron Phosphate Battery (Li-FePo4)
Self-Test
Accessory
Emergency downlight with integralinverter and battery pack
Escape Route
Open Area
IP65
LED Information
Total (Watts) 3WLumens DeliveredEmergency ModeOpen Area 114lmEscape Route 90lmBeam Angle Open Area 43.3°Escape Route 132°CCT 6500KInput 220/240VHertz 50/60HzOperating Temp 0C° to 40C°
Mounting Height (M)
2.546
2.5 2.8 2
4.88 6.69 8.5
2.5 2.8 2
4.88 6.69 8.5
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
--**
--**
43**
1011**
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
5YR457
www.anselluk.comwww.anselluk.com
AMELED/OA/3NM/ST AMELED/ER/3NM/ST/B
Merlin LED Emergency DownlightSupplied c/w Remote Driver and Battery Pack
3YR ST
• Ultra-lowprofilerecessedself-test emergency downlight
• Self-test as standard• Option of escape route or
open area models• Highspecificationoptic
design and performance allows increased spacing providing reduced cost
• Up to 17.8 metres spacing between luminaires
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Ø85
57
72
IP20
Self-Test
Accessory
Code Lamp Description
AMELED/ER/3NM/ST LED 5W Non-Maintained - Escape Route
AMELED/OA/3NM/ST LED 5W Non-Maintained - Open Area
AMELED/ER/3NM/ST/B LED 5W Non-Maintained - Escape Route - Black
AMELED/OA/3NM/ST/B LED 5W Non-Maintained - Open Area - Black
ASBP/9 3.6V 4.5Ah Ni-Cd Replacement Battery
LED Information
Total (Watts) 5WLumens DeliveredEmergency ModeOpen AreaEscape RouteBeam Angle Open AreaEscape RouteCCTInputHertzOperating Temp
259lm247lm
110°140°6500K230V50/60Hz0°C to 45°C
/B191lm229lm
108°140°
Mounting Height (M)
2.54
2.54
----
----
5.57.557
1419.614
19.5
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
AMELED/ER/3NM/ST
AMELED/ER/3NM/ST/B
Mounting Height (M)
2.546
2.546
34534
4.5
6.59.511.5
6910
34534
4.5
6.59.511.5
6910
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum)**
Axial to Wall
Axial to Axial
***
AMELED/OA/3NM/ST
AMELED/OA/3NM/ST/B
2YR458
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
IP65 Falcon LED Surface Emergency DownlightSupplied c/w Integral Driver and Battery Pack
3YRST
• Compact surface ultra-low profilerecessedself-testemergency downlight
• Self-test as standard• Supplied with open
area and escape route interchangeable lenses
• Highspecificationopticdesign and performance allows increased spacing providing reduced cost
• Up to 19.6 metres spacing between luminaires
• BESA mounting option
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
IP65
16555.7
Self-Test
Accessory
Code Lamp Description
AFALED/3NM/ST/IP65 LED 4W Non-Maintained
AFALED/3NM/ST/IP65/B LED 4W Non-Maintained - Black
ASBP/10 3.6V 3Ah Ni-Cd Replacement Battery
LED Information
Total (Watts) 4WLumens DeliveredEmergency ModeOpen AreaEscape RouteBeam Angle Open AreaEscape RouteCCTInputHertzOperating Temp
152lm247lm
96°140°6500K230V50/60Hz0°C to 45°C
/B142lm116lm
96°135°
Open Area Lens Escape Route Lens
AFALED/3NM/ST/IP65
AFALED/3NM/ST/IP65/B
Mounting Height (M)
2.54
2.54
----
----
4.24.25
43.6
10129.511
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
AFALED/ER/3NM/ST
AFALED/ER/3NM/ST/B
Mounting Height (M)
2.546
2.546
2.53.54
2.53.54
57.19.84.86.89.8
2.53.54
2.53.54
57.19.84.86.89.8
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum)**
Axial to Wall
Axial to Axial
***
AFALED/OA/3NM/ST
AFALED/OA/3NM/ST/B
2YR459
www.anselluk.comwww.anselluk.com
Top Housing View
Bottom Housing Viewshowing Emergency LED
LED Panel Pod Emergency for Infinite and Endurance LED Panels
3YR ST
• Integral emergency pod to convert any new Ansell
InfiniteLEDandEnduranceLED panel to emergency, instantly
• Simple, quick twist and lock fixing
• Supplied with a pre-wired 1 Metre cable for ease of installation
• Tri-colour LED shows green for healthy running condition,red/flashingforfault conditions and white for emergency operation
• UK Patent No. GB2522285• European Patent No.
15165652.7 • Irish Patent No. 2015/0128• EC Registered Design No
002712232-0001
170
53
LED Information
Total (Watts) 5WLumens Delivered Emergency Mode 189lmBeam Angle 120°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
Self-Test
Accessory
Code Lamp Description
AIRMLED/POD/3NM/ST LED 5W - Cool White
ASBP/11 3.6V 4.5Ah Ni-Cd Replacement Battery
STEP 2Locate and twist Panel Pod into position. Connect incoming supply to pre-leaded cable
STEP 1Unscrew coin plug from back of Ansell LED Panels
IP20
2YR460
Project - Ducati ShowroomStoke, UK
461