SEARCH. É. Vaskövi 1 , O. Udvardy 1 , M. Endrődy 1 , T. Beregszászi 1 , P. Rudnai 1 , É. Csobod 2 1 Department of Air Hygiene NCPH-NIEH 2 Regional Environmental Centre for Central and Easter Europe, Hungarian Office. Project Implementation phase 2. 27-28 March 2009 , Bratislava, Slovakia. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/1.jpg)
É. Vaskövi1, O. Udvardy1, M. Endrődy1, T. Beregszászi1, P. Rudnai1,
É. Csobod2
1Department of Air Hygiene NCPH-NIEH2Regional Environmental Centre for Central and
Easter Europe, Hungarian Office
SEARCHSEARCH
27-28 March 2009 , Bratislava, Slovakia
![Page 2: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/2.jpg)
Identify the exposure level in combination with building characteristics and occupant behaviour and activities
Analyse the passive samples
Compare the air quality data measured by the participating centres
Evaluation of the relationship between measured concentrations and possible emission sources
Draw the conclusions
![Page 3: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/3.jpg)
IAQ-related health problems in schools
IAQ can potentially affect the health of students /staff in the educational process
Children are more susceptible to poor IAQ
Students spend 4-8 hrs a day in school
Magnitude of schoolchildren population
IAQ pollutants are 2 to 5 times higher
![Page 4: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/4.jpg)
Within the school building
Polluted outdoor air (traffic, industry)
![Page 5: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/5.jpg)
HCHO BTEX
1.panelling
2.fabric
3.plywood
4.floor carpet
5.furniture
6
5
3
2
1
8
7
6.board
7. plastic flooring
8.oil paint
9.furniture
4
CHARACTERISTIC INDOOR SOURCES IN HUNGARIAN
SCHOOLS
![Page 6: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/6.jpg)
MONITORING MONITORING PROGRAMPROGRAM
![Page 7: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/7.jpg)
ALBANIABOSNIA**HUNGARY
ITALY*SERBIA
SLOVAKIA
* results aren’t integrated** pollution data are presented only
![Page 8: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/8.jpg)
Country Town number
School number
Class number
Albania 3 10 35
Bosnia 3 10 40
Hungary 4 10 43
Serbia 7 10 44
Slovakia 2 10 40
![Page 9: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/9.jpg)
INDOOR INDOOR classroom, in the breathing zone
OUTDOOR ambient air, closest to the window of the classroom
![Page 10: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/10.jpg)
Country Beginning date
End date
Albania 22/01/2008 04/04/2008
Bosnia 24/12/2007 17/04/2008
Hungary 05/11/2007 29/02/2008
Serbia 28/01/2008 09/05/2008
Slovakia 03/12/2007 14/03/2008
![Page 11: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/11.jpg)
![Page 12: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/12.jpg)
![Page 13: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/13.jpg)
REAL-TIME MONITORING
T, RH, CO2, CO PM
INTEGRATED (PASSIVE) SAMPLING NO2 BTEX, H2CO
![Page 14: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/14.jpg)
Protocol for field work Training and consultation The same portable monitors and
passive samplers Blank samples Passive samples were collected by the
countries and analysed by one laboratory
Samples transportation were performed in compliance with the same protocol
![Page 15: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/15.jpg)
RESULTSRESULTS
![Page 16: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/16.jpg)
![Page 17: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/17.jpg)
![Page 18: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/18.jpg)
![Page 19: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/19.jpg)
0
1000
2000
3000
4000
5000
Albania Hungary Serbia Slovakia
average
max
![Page 20: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/20.jpg)
0
5
10
15
20
25
30
Albania Bosnia Hungary Serbia Slovakia
average
max
![Page 21: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/21.jpg)
0
10
20
30
40
50
60
70
80
90
100
Albania Bosnia Hungary Serbia Slovakia
average
max
![Page 22: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/22.jpg)
![Page 23: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/23.jpg)
HCHO P
CO2- values
PM10
AlbaniaClassroom crowdness (7 category) 0,0432
The wall is covered by white-wash 0,0136
When were the walls painted last time 0,0254
HungaryOrientation of the classroom: facing the street 0,0353 0,0563
The floor is made of wood 0,0518 0,0009
Time of opened windows (<1 h) 0,0029
SerbiaOn which floor is this classroom situated 0,0190
Windows not opened 0,0105 0,0976
How frequently are the windows opened 0,0769
SlovakiaOrientation of the classroom: facing the street 0,0376
The floor is covered with carpet 0,0736 0,0736
Classroom crowdness (<2m2; <6m3) 0,0887
![Page 24: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/24.jpg)
CONCLUSIONSCONCLUSIONS
![Page 25: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/25.jpg)
HCHO
Orientation of the classroom: facing the street Slovakia
When were the walls painted last time AlbaniaThe floor is made of wood Hungary
The floor is covered with carpet Slovakia
Windows not opened Serbia
CO2
Orientation of the classroom: facing the street HungaryTime of opened windows (<1 h) Hungary
How frequently are the windows opened Serbia
PM10
On which floor is this classroom situated Serbia
Orientation of the classroom: facing the street Hungary
Classroom crowdness Albania, SlovakiaThe wall is covered by white-wash AlbaniaThe floor is made of wood HungaryThe floor is covered with carpet SlovakiaWindows not opened Serbia
![Page 26: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/26.jpg)
- Facing the street: HCHO ↑ CO2 ↑ PM10↑
outdoor sources or not enough ventillaton?
- Fresh painting → HCHO ↑
- Floor: wood or carpet → HCHO ↑ PM10↑
- Classroom crowdness → PM10↑
![Page 27: Project Implementation phase 2](https://reader035.vdocuments.net/reader035/viewer/2022062305/56814907550346895db63fa1/html5/thumbnails/27.jpg)