project review: jay st health club team 01 edwin vega ......the structure follow a standard grid of...

6
Project Review: Jay St Health Club Team 01 Edwin Vega Melanie louie Nicolas Chamorro Osei Salmon Tatiana Zheludkova

Upload: others

Post on 17-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Project Review: Jay St Health Club Team 01 Edwin Vega ......The structure follow a standard grid of 20’x20’ and 25’x25’ bay system. The columns appears to be the same size

Project Review:Jay St Health Club

Team 01

Edwin Vega Melanie louie

Nicolas Chamorro Osei Salmon

Tatiana Zheludkova

Page 2: Project Review: Jay St Health Club Team 01 Edwin Vega ......The structure follow a standard grid of 20’x20’ and 25’x25’ bay system. The columns appears to be the same size

The structure follow a standard grid of 20’x20’ and 25’x25’ bay system. The columns appears to be the same size. At the center, there is a long span to give space for the frame of the pool. The materials used are steel and concrete.

ARCH 2330prof. king

Edwin VegaStructual Review

A

1

SCALE: NSTSTRUCTURAL GRID1

S1.01

20' 20' 25' 25' 25' 25' 25' 15'

25'

25'

25'

25'

25'

20'

B

C

D

E

F

G

2 3 4 5 6 7 7 9

Page 3: Project Review: Jay St Health Club Team 01 Edwin Vega ......The structure follow a standard grid of 20’x20’ and 25’x25’ bay system. The columns appears to be the same size

ARCH 2330prof. king

Mechanical Review Osei Salmon

Page 4: Project Review: Jay St Health Club Team 01 Edwin Vega ......The structure follow a standard grid of 20’x20’ and 25’x25’ bay system. The columns appears to be the same size

ARCH 2330prof. king

Room Name and Numbering Melanie Louie

Room Name and Numbering System Floor Level Code Floor Level Name Room Name Room Code

LR Locker Room Mechanical Room LRMR0 Laundry Room LRLR0

G Ground Floor Lobby GL1 Pool GP1 Garden GG1 Cafe GC1 Kitchen GK1 Rockwall Studio GRS1

S1 Second Floor Rockwall Studio S1RS2 Exercise Studio S1ES2 Office S1O2

S2 Exercise Floor Exercise Room S2ER2-1 T Third Floor Rockwall Studio TRS3 Exercise Studio TES3 Office TO3 F Fourth Floor Rockwall Studio FRS4 Exercise Studio FES4 Office FO4

Page 5: Project Review: Jay St Health Club Team 01 Edwin Vega ......The structure follow a standard grid of 20’x20’ and 25’x25’ bay system. The columns appears to be the same size

ARCH 2330prof. king

Program Review Tatiana Zheludkova

Occupancy Classification.

According to Building Code Health Club belongs to the Assembly Group A-3 and Business Group B.

303.1 Assembly Group A.

Assembly Group A occupancy includes, among others, the use of a building or structure or a por-tion thereof, excluding a dwelling unit, for the gathering of any number of persons for purposes such as civic, social or religious functions, recreation, food or drink consumption, awaiting transportation, or similar group activities; or when occupied by 75 persons or more for educational or instructional purposes.

Exceptions:

1. A building or nonaccessory tenant space used for assembly purposes with an occupant load of fewer than 75 persons shall be classified as a Group B occupancy, except that the number of plumb-ing fixtures for such a building or space is permitted to be calculated in accordance with the require-ments for assembly occupancies.

2. A room or space used for assembly purposes with an occupant load of fewer than 75 persons and accessory to another occupancy shall be classified as a Group B occupancy or as part of that occu-pancy, except VB permitted to be calculated in accordance with the requirements for assembly occupancies.

304.1 Business Group B.

Business Group B occupancy includes, among others, the use of a building or structure, or a portion thereof, for office, professional, service-type transactions, or for conducting public or civic services, including the incidental storage of records and accounts and the incidental storage of limited quantities of stocks of goods for office use or purposes.

Page 6: Project Review: Jay St Health Club Team 01 Edwin Vega ......The structure follow a standard grid of 20’x20’ and 25’x25’ bay system. The columns appears to be the same size

ARCH 2330prof. king

Egress Study Nicolas Chamorro