Page 1: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

OCTAGON Implant System

PROOF DATE: Feb 4

Page 2: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t e OPPORTUNITIES IN IMPLANTOLOGY

ACE Surgical Supply Co., Inc. • 1.800.441.3100 • acesurgical.com1034 Pearl Street, Brockton, MA 02301 • E-Mail: [email protected]

For almost 50 years ACE Surgical has been dedicated to dental surgical advancements.We continue to develop and manufacture the highest quality, state-of-the-art products at competitive prices; while keeping customer service at the core of our business. Infinity dental implant systems allow you to place and restore our implants with confidence and without the added expense. The infinity OCTAGON Dental Implant System is committed to delivering a functional and esthetic dental implant solution to both you and your patients. infinity Implants—infinite innovation, endless opportunities in implantology.

Page 3: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

1

Table of contentsIntroduction .....................................................................3

Features and Benefits ................................................... 4-5

Octagon Implant Offerings ........................................... 6-9

Drilling Sequences ................................................... 10-11

Surgical Drills, Drivers, and Kit ................................ 12-15

Prosthetics ................................................................ 16-19

Prosthetics, Zest Locators ................................................20

Surgical Protocols .................................................... 21-24

Prosthetic Protocols .................................................. 25-28

Warranty .......................................................................29

ACE Surgical Supply Co., Inc.1034 Pearl Street, Brockton, MA 02301 - USA1-800-441-3100 • www.acesurgical.com

Copyright © 2015 ACE Surgical Supply Co., Inc. Reproduction in whole or part is specifically prohibited without written permission.

Denta l Implant Systems

Page 4: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

Introduction OCTAGON IMPLANTS

Page 5: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

3

The infinity OCTAGON implant system has been designed to work with some of the leading internal octagon configured systems in the market today. The infinity OCTAGON platform allows for a secure morse tapered connecting interface between the implant and prosthetic components. The precise manufacturing of the OCTAGON implant is what separates this system from other compatible dental implant systems.

The implants are manufactured from high-strength, bio-compatible pure titanium grade 4. The implant’s

Sandblasted and Acid-etched surface treatments result in a rougher surface providing a greater surface area for osseointegration.

The available prosthetics options for the infinity OCTAGON are designed to offer familiar options without the inflated costs. From a single tooth restoration to a full arch case, infinity OCTAGON prosthetics are esthetic, functional and, easy to use at a price that makes sense for your practice.

4.1mmTaperedImplant

4.1mmStraightImplant

3.3mmStraightImplant

4.8mmStraightImplant

4.8mmStraightImplant

OCTAGON TISSUE LEVEL (TL)WIDE PLATFORM (WP)

Ø6.5mm WP

OCTAGON TISSUE LEVEL (TL)REGULAR PLATFORM (RP)

Ø4.8mm RP

Page 6: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem4

INTERNAL OCTOGNAL CONNECTION

Infinity OCTAGON implants with a morse connection, has been designed to work with some of the leading internal octagon implants in the market today.

Use your existing surgical instrumentation to place the OCTAGON implant or utilize the precision engineered driver that comes standard with the surgical kit.

The drivers are available in both a contra-angle or ratchet configuration.

1.8 MM HEIGHT POLISHED COLLAR

The coronal section of this implant has a 1.8 mm polished collar. Due to its geometry, the implant design respects the biological width used in an extended range of indications.

Depending on the surgical evaluation, this type of implant can be placed transgingival, semigingival or subgingival thus providing optimal soft tissue management.

STRAIGHT & TAPERED

The infinity OCTOGON Implant System is available in STRAIGHT RP, WP and TAPERED RP designs.

The TAPERED RP Implant design is ideal for immediate (same day as extraction) and early implantation (6-8 weeks post extraction).

REGULAR (RP) AND WIDE PLATFORM (WP) TISSUE LEVEL IMPLANTS

TEXTURED SURFACE

The surfaces in the endosteal section are Sandblasted wi th Large par t ic les of corundum (> 99% Al2O3 = a l u m i n i u m o x i d e ) and Acid-etched.

The macro-roughness exhibits a roughness profile of 20 to 40 μm with micro-roughness of 2.0 to 4.0 μm.

RP Regular Platform

STRAIGHT

LIFETIME WARRANTY

The ACE Surgical implant warranty program is designed to support all clinicians involved with the infinity Implant System.

(See page 29 for details)

WP Wide

Platform

TAPERED

Page 7: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 5

COVER SCREW

Included with every implant inside the inner blister, below the vial.

STERILE PACKAGING

All implant and accompanying cover screw come packaged sterile. The package is labeled with easy to identify product information.

CONTAINED IMPLANT

Vial packed implant suspension and easy to retrieve cover screw.

IMPLANT BOX

Implant style, size and platform specifications are clearly marked to distinguish the OCTAGON product.

INSTRUCTIONS

Every implant comes complete with instructions for use and implant package removal instructions.

PATIENT RECORD LABELS

Every implant is packaged complete with patient labels.

IMPLANT SUSPENSION CHAMBER

The suspension chamber securely suppports the implant, which allows for easy removal once the cap has been removed.

IMPLANT TRANSFER

Titanium support transfer and transfer screw is included and packaged sterile. The implant transfer is connected to the implant for secure implant placement or implant removal from the vial.

Page 8: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem6

Length

Ø4.8mm Regular Platform

3.3mm Implant Width (Straight)

2.8mm Apex

1.8mm Collar Height1.0mm Pitch

Ø4.8mm Tissue Level

Regular Platform

OCTAGON TL RP3.3mm Straight Implant

Length 4.1mm Implant Width (Straight)

Ø4.8mm Regular Platform

3.5mm Apex

1.8mm Collar Height1.25mm Pitch

Product No. 504108 504110 504112 504114

Diameter Ø4.1mm Ø4.1mm Ø4.1mm Ø4.1mm

Length 8mm 10mm 12mm 14mm

Product No. 503308 503310 503312 503314

Diameter Ø3.3mm Ø3.3mm Ø3.3mm Ø3.3mm

Length 8mm 10mm 12mm 14mm

Ø4.8mm Tissue Level

Regular Platform

OCTAGON TL RP4.1mm Straight Implant

RP IMPLANT COVER SCREW Included sterile

with implant

5031154

RP IMPLANT COVER SCREW Included sterile

with implant

5031154

Page 9: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 7

Product No. 504808 504810 504812 504814

Diameter Ø4.8mm Ø4.8mm Ø4.8mm Ø4.8mm

Length 8mm 10mm 12mm 14mm

Ø4.8mm Tissue Level

Regular Platform

OCTAGON TL RP4.8mm Straight Implant

Ø4.8mm Tissue Level

Regular Platform

OCTAGON TL RP Healing Caps

Length

Ø4.8mm Regular Platform

4.2mm Apex

1.8mm Collar Height1.25mm Pitch

4.8mm Implant Width (Straight)

Product No. 5031155 5035683 5035736 5035751

Platform Ø4.8mm Ø4.8mm Ø4.8mm Ø4.8mm

Collar Width 4.8mm 4.8mm 4.8mm 4.8mm

Collar Height 1.5mm 2.0mm 3.0mm 4.5mm

Collar Width

Collar Height

CW

CH

• For use with RP and RPT Implants• Uses Octagon Screwdrivers• Recommended Seating Torque 15 N-cm

RP IMPLANT COVER SCREW Included sterile

with implant

5031154

Page 10: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem8

Product No. 504110T 504112T

Diameter Ø4.1mm Ø4.1mm

Length 10mm 12mm

Length

Ø4.8mm Regular Platform

3.5mm Apex

1.8mm Collar Height (Polished Neck)0.8mm Pitch

4.1mm Implant Width (Tapered)

Ø4.8mm Tissue Level

Regular Platform

Ø4.8mm Tissue Level

Regular Platform

OCTAGON TL RP Healing Caps

Product No. 5031155 5035683 5035736 5035751

Platform Ø4.8mm Ø4.8mm Ø4.8mm Ø4.8mm

Collar Width 4.8mm 4.8mm 4.8mm 4.8mm

Collar Height 1.5mm 2.0mm 3.0mm 4.5mm

Collar Width

Collar Height

CW

CH

• For use with RP and RPT Implants• Uses Octagon Screwdrivers• Recommended Seating Torque 15 N-cm

OCTAGON TL RPT4.1mm Tapered Implant

RP IMPLANT COVER SCREW Included sterile

with implant

5031154

Page 11: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 9

Product No. 504808WP 504810WP 504812WP

Diameter Ø4.8mm Ø4.8mm Ø4.8mm

Length 8mm 10mm 12mm

Length

Ø6.5mm Wide Platform

1.8mm Collar Height (Polished Neck)1.25mm Pitch

4.8mm Implant Width (Straight)

Ø6.5mm Tissue Level

Wide Platform

Ø6.5mm Tissue Level

Wide Platform

OCTAGON TL WP Healing Caps

Product No. 5093731 5093732 5093733

Platform Ø6.5mm Ø6.5mm Ø6.5mm

Collar Width 6.5mm 6.5mm 6.5mm

Collar Height 2.0mm 3.0mm 4.0mm

Collar Width

Collar Height

CW

CH

• For use with WP Implants• Uses Octagon Screwdrivers• Recommended Seating Torque 15 N-cm

OCTAGON TL WP4.8mm Straight Implant

4.2mm Apex

WP IMPLANT COVER SCREW Included sterile

with implant

5093730

Page 12: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem10

OCTAGON Drilling SequencesNote: Instruments shown are drilling for a 10mm implant. Adjust accordingly for other implant depths.

Ø 3.3mm Profile Drill

Ø 3.3mm Bone Tap

Ø 2.2mm Round

Bur

Ø 2.2mm Round

Bur

Ø 2.0mm Ø 3.0mm Parallel

Pin

Ø 2.0mm Ø 3.0mm Parallel

Pin

Ø 2.2mm Twist Drill

Ø 2.2mm Twist Drill

Ø 2.2mm Twist Drill

Ø 2.2mm Twist Drill

Ø 2.0mm Depth Gauge

Ø 2.8mm Twist Drill

4.1mm RPRegular Platform Straight ImplantØ4.8mm Platform

3.3mm RPRegular Platform Straight ImplantØ4.8mm Platform

*16mm

*14mm

12 mm

10mm

8mm

6mm

Drill Laser Markings

*Note: Short Drills

do not include 14 or 16mm

Ø 4.1mm Profile Drill

Ø 4.1mm Bone Tap

Ø 3.5mm Twist Drill

Ø 3.0mm Depth Gauge

Ø 2.0mm Depth Gauge

Ø 2.8mm Twist Drill

Page 13: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 11

Ø 4.8mm Tap

Ø 2.2mm Round

Bur

Ø 2.2mm Round

Bur

Ø 2.2mm Twist Drill

Ø 2.2mm Twist Drill

Ø 2.2mm Twist Drill

Ø 2.2mm Twist Drill

Ø 3.5mm Twist Drill

Ø 3.5mm Twist Drill

Ø 3.0mm Depth Gauge

Ø 3.0mm Depth Gauge

Ø 2.0mm Depth Gauge

Ø 2.0mm Depth Gauge

Ø 2.8mm Twist Drill

Ø 2.8mm Twist Drill

Ø 4.1mm Profile Drill

Ø 4.1mm Bone Tap Tapered

RPT

4.1mm RPTRegular Platform Tapered ImplantØ4.8mm Platform

4.8mm RPRegular Platform Straight ImplantØ4.8mm Platform

4.8mm WPWide Platform

Straight ImplantØ6.5mm Platform

Ø 4.2mm Twist Drill

*

Ø 2.0mm Ø 3.0mm Parallel

Pin

Ø 2.0mm Ø 3.0mm Parallel

Pin

Ø 4.8mm Profile Drill

WP only*

Page 14: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem

i n f i n i t y OCTAGON Surgical Drills, Drivers, and Kit

Page 15: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 13

CERTIFIED PRECISION

Manufactured under strictly controlled Swiss machining guidelines and certified to ISO 13485 regulations.

LASER MARKED

Precise laser markings allow for accurate identification for drill depth to create osteotomy.

BUILT TO LAST

Manufactured from hardened, high strength, corrosive-resistant surgical grade stainless steel. Engineered for multiple use.

THREE CUTTING FLUTES

Three (3) fluted twist drills allow for an easy on-center drilling process.

PROVEN DESIGN

Proven twist drill geometry allows efficient bone chip removal.

Page 16: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem14

Ø 2.2mm ROUND

BUR

5031061

Ø 2.2mm TWIST DRILL SHORT

5038120

Ø 2.2mm TWIST DRILL LONG

5038121

Ø 2.8mm TWIST DRILL SHORT

5038149

Ø 3.3mm BONE TAP

TL RP SHORT

5095267

Ø 3.3mm BONE TAP

TL RP LONG

5072268

Ø 3.3mm PROFILE

DRILL TL RP

5038137

IMPLANT DRIVER

HANDPIECE SHORT

5031056

IMPLANT DRIVER

RATCHET SHORT

5064558

IMPLANT DRIVER

HANDPIECE LONG

5031057

IMPLANT DRIVER

RATCHET LONG

5017372

SCREWDRIVER HAND/

RATCHET SHORT

5063978

SCREWDRIVER HAND/

RATCHET LONG

5064553

SCREWDRIVER HAND/

RATCHET MEDIUM

5064551

SCREWDRIVER HANDPIECE

CONTRA ANGLE

5031052

Ø 2.8mm TWIST DRILL LONG

5038148

OCTAGON Surgical Kit Components

Ø 2.0mm Ø 3.0mm

PARALLELING PINS

5079575 x4

A B C D

Page 17: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 15

DRILL EXTENDER HANDPIECE

04959901

HOLDING KEY

5064563

Ø 3.5mm TWIST DRILL SHORT

5038135

Ø 4.2mm TWIST DRILL SHORT

5038151

Ø 4.1mm BONE TAP

TL RP SHORT

5095265

Ø 4.1mm BONE TAP

TL RP LONG

5031088

Ø 4.8mm BONE TAP

TL RP LONG

5061314

Ø 4.8mm BONE TAP

TL RP SHORT

5095266

TORQUE RATCHET

5089048

Ø 3.5mm TWIST DRILL LONG

5038136

Ø 4.2mm TWIST DRILL LONG

5038152

Ø 4.8mm PROFILE

DRILL TL WP

5093738

Ø 2.0mm DEPTH GAUGE

5064557

Ø 3.0mm DEPTH GAUGE

5064556

Ø 4.1mm PROFILE

DRILL TL RP (TD)

5093740

Ø 4.1mm BONE TAP

RPT Tapered (BL/TD)

5095264

COMPLETE INFINITY OCTAGON SURGICAL KIT

5082895

Ø 4.1mm PROFILE

DRILL TL RP

5038147

E

Page 18: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem16

Product No. 5057041

Height 5.5mm

RP BASIC SCREW Included with

Digital Abutment

5057042

Titanium Abutment

• Recommended torque 35 N-cm• Titanium Base

Solid Abutment Plastic Copings

Solid Abutment Analogs

i n f i n i t y OCTAGON TL ProstheticsOCTAGON TISSUE LEVEL RP

SOLID ABUTMENTSFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants

OCTAGON TISSUE LEVEL RP

TITANIUM ABUTMENTFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants

Solid Abutment Transfer ComponentsClosed Tray Impressions

Product No. 5055283 5055288 5055299 5055394

Type Impression Cap PositioningCylinder

PositioningCylinder

PositioningCylinder

Color for all Solid Abutments Yellow Grey Blue

Product No. 5055478 5055487

Type Bridge Crown

Product No. 5055396 5055397 5055400

Color Yellow Grey Blue

Solid Abutments

• Recommended seating torque 35 N-cm using an Solid Abutment Driver

Product No. 5081038 5081083 5081096

Height 4mm 5.5mm 7mm

Color Yellow Grey Blue

SOLID ABUTMENT

DRIVER Short

5055668

SOLID ABUTMENT

DRIVER Long

5072088

Page 19: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 17

i n f i n i t y OCTAGON TL Prosthetics

Product No. 5031164 5031165 5031166

Height 1.5mm Bridge Crown

Type Straight Plastic Coping Plastic Coping

Screw Retained Abutment

• Recommended torque 35 N-cm

RP OCCLUSAL SCREW

Requiered for All Screw Retained

Abutments

5031160

Product No. 5055283 5084957 5031156 5031157

Product Name Impression Cap

Positioning Cylinder

Impression Cap(w/Guide Screw)

Implant Analog

Tray Type Closed Tray Closed Tray Open Tray Open Tray

Implant Level Open/Closed TrayImpression Components

• Recommended torque 35 N-cm

Straight Abutment

• Recommended torque 35 N-cm

Product No. 5031161 5031162 5031163

Height 5.5mm Bridge/Bar Crown

Type Straight Cementable

Plastic Coping

Plastic Coping

Angled Abutments

• Recommended torque 35 N-cm

RP OCCLUSAL SCREW

Requiered for All Screw Retained

Abutments

5031160

Product No. 5038118 5038119 5038117 5038116 5082689

Height 6.7mm 5.7mm 6.7mm 5.7mm RP Plastic Shoulder

Type

A 15º (see below)

Cementable Only

A 20º (see below)

Screwed or Cementable

B 15º (see below)

Cementable Only

B 20º(see below)

Screwed or Cementable

For 15º / 20º Angled

Abutments

OCTAGON TISSUE LEVEL RP

ANGLED AND STRAIGHT ABUTMENTSFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants

VERSION A: Angled against the vertex of the Octagon

VERSION B: Angled against one of the flat sides of the Octagon

Page 20: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem18

OCTAGON TISSUE LEVEL WP

ANGLED AND STRAIGHT ABUTMENTSFits 4.8mm Wide Platform Implants

Implant Level Open TrayImpression Components

• Recommended torque 35 N-cm

Product No. 5093734 5093735

Product Name Impression Cap(w/Guide Screw) Implant Analog

Tray Type Open Tray Open Tray

Screw Retained Abutment

• Recommended torque 35 N-cm

Product No. 5093720 5093721 509722

Height 1.5mm Bridge/Bar Crown

Type Straight Plastic Coping Plastic Coping

RP OCCLUSAL SCREW

Requiered for All Screw Retained

Abutments

5031160

Straight Abutment

• Recommended torque 35 N-cm

Product No. 5093736

Height 5.5mm

Type Straight Cementable

RP OCCLUSAL SCREW

Requiered for All Screw Retained

Abutments

5031160

Angled Abutments

• Recommended torque 35 N-cm

Product No. 5093739 5093737

Height 5.5mm 5.5mm

Type

A 15º (see below)

Cementable Only

B 20º (see below)

Cementable Only

VERSION B: Angled against one of the flat sides of the Octagon

VERSION A: Angled against the vertex of the Octagon

Page 21: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 19

ZEST LOCATOR® LAB COMPONENTS

REPLACEMENT PROCESSING PACKS• Available in various

retention strengths

• Packages of 4

Zest LOCATOR® Analog - 4/pkg

206-8516

Zest LOCATOR® Torque Wrench

Contra Angle Driver

206-8914

Zest LOCATOR® White Block-Out Spacer - 20/pkg

206-8514

Zest LOCATOR® Male Installation / Removal Tool

206-8393

Using the Zest LOCATOR®

Male Installation / Removal Tool

A end for hand installing LOCATOR Abutments

B end for changing the retention males

Zest LOCATOR® Transfer - 4/pkg

206-8505

REPLACEMENT MALE - SETSDual Retention Replacement MaleTwo retention surfaces, the outer ring and the center nipple allows for maximum hold. Good for use with divergent implants up to 10° (accommodates up to 20° between 2 or more implants).

Extended Range Replacement MaleSingle retention surface using only the outer ring with the inner nipple removed. Good for use with divergent implants up to 20° (accommodates up to 40° between 2 or more implants).

Each Set includes:(1) Denture Cap with Black Processing Male(1) White Block-Out Spacer (3) Nylon Retention Males: 1 of each retention strength

Zest LOCATOR® Replacement Dual Retention Male Sets

2 sets / pkg 10 sets / pkg 206-85192 206-851910

Zest LOCATOR® Replacement Extended Range Male Sets

2 sets / pkg 10 sets / pkg 206-85402 206-854010

Product No. 206-08621 206-08622 206-08623 206-08624

Platform TL RP TL RP TL RP TL RP

Collar Height 1.25mm 2.25mm 3.25mm 4.25mm

Color CLEAR PINK BLUE GREEN ORANGE RED

Product No. 206-8524 206-8527 206-8529 206-8547 206-8915 206-8548

Retention Standard Light Extra Light Standard Light Extra Light

Lbs. 5 lbs. 3 lbs. 1.5 lbs. 3-4 lbs. 2 lbs. .5-1.5 lbs.

Grams 2268 1361 680 1361-1814 907 226-680

Male Processing Pack (Dual Retention)

Male Processing Pack (Extended Range)

OCTAGON TISSUE LEVEL RP

ZEST LOCATOR® ABUTMENTFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants

• Recommended seating torque 35 N-cm using a One-Piece Screwdriver with Torque Wrench (included with kit)

A B

Page 22: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem20

i n f i n i t y OCTAGON Surgical Protocol

Product No. 5038087

Height 0mm

Product No. 5089611 5089612 5089613

Color Red O-Ring Blue O-Ring Black O-Ring

Retention 1 lbs 2 lbs 3 lbs

Adapter for Ball

Abutment

5038073

Matrix for Ball Abutment

Includes O-Rings

5082758

Ball Abutment Analog

5038071

OCTAGON TISSUE LEVEL RP

BALL ABUTMENTS AND COMPONENTSFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants

Ball Abutment & Attachments• Recommended seating torque

35N-cm using the Adapter for Ball Attachment.

Page 23: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 21

OCTAGON Implant Placement ProtocolImplant Site Preparation

Step 1 - Determine Tissue Depth• Prior to drilling, use a tissue probe to determine the soft

tissue depth.

Step 2 – Preparing the Surgical Site• Make a mesio-distal incision along the buccal side of the

alveolar crest through the mucoperiosteum and attached gingiva to the bone and reflect the flap.

Step 3 - Marking the Implant Site• Using a handpiece at a maximum speed of 800rpm and

copious irrigation, mark the initial osteotomy using the Ø2.2mm round bur.

Step 4 - Drilling the Pilot Hole• Drill the initial pilot osteotomy using the Ø2.2mm twist

drill at a maximum speed of 800rpm.

• Drill to the 6mm laser marking.

Step 5 - Check Parallel Alignment• Confirm the appropriate angle with the

Ø2.0mm Alignment Pin.

• Osteotomy corrections can be made during the following drilling step.

Step 6 - Drill to Implant Depth• Using the same Ø2.2mm twist drill at a maximum speed

of 800rpm, drill to the final implant depth.

• Drill to the 6mm laser marking.

Site Preparation of the Implant Bed (Example shown for Ø4.8mm x 12mm length)

Continued on following page

1 2

3 4

65

i n f i n i t y OCTAGON Surgical Protocol

*16mm

*14mm

12 mm

10mm

8mm

6mm

Drill Laser Markings

*Note: Short Drills

do not include 14 or 16mm

Page 24: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem22

OCTAGON Implant Placement ProtocolImplant Site Preparation

Step 7 - Drill for all Implant Diameters

Select the Ø2.8mm twist drill. Drill to appropriate implant length at a maximum speed of 600rpm. Proceed to Step 7.

NOTE: If placing a Ø3.3mm implant, this is the final drilling step. Proceed to step 10.

Step 8 - Check Depth Confirm the appropriate drill depth with the

Ø2.0mm Depth Gauge.

Step 9 - Drill for Ø4.1mm and Ø4.8mm Implants

Select the Ø3.5mm twist drill. Drill to appropriate implant length at a maximum speed of 500rpm.

NOTE: If placing a Ø4.1mm implant, this is the final drilling step. Proceed to step 10.

Step 10 - Drill for Ø4.8mm Implants

Select the Ø4.2mm twist drill. Drill to appropriate implant length at a maximum speed of 400rpm.

NOTE: If placing a Ø4.8mm implant, this is the final drilling step. Proceed to step 10.

Step 11 - Check Depth Confirm the appropriate drill depth with the

Ø3.0mm Depth Gauge.

Step 12 - Profile Drill Select the corresponding profile drill for the implant

being installed and drill to the score line of the profile drill at a maximum speed of 400rpm to place implant at tissue level.

Step 13 - Bone Tap When drilling in dense bone, select the corresponding

bone tap for the implant being installed and tap to the appropriate implant length.

Site Preparation of the Implant Bed (Example shown up to the Ø4.8mm x 12mm length)

8

11

13

12

109

7

Page 25: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 23

OCTAGON Implant Placement ProtocolLoading Implant Onto Driver

Step 1 - Implant Packaging• Remove the OCTAGON Dental Implant Tyvek® sealed blister

package from the outside box. Open this blister package over a sterile field by locating and pulling off the sealed Tyvek® lid. With the blister package open, drop the sterile inner implant vial onto the sterile field.

Step 2 - Choose the Driver • Pick up the OCTAGON Dental Implant body from the vial by

using either the ratchet or contra-angle driver tool.

Step 3A - Loading the Driver • Carefully engage the transfer abutment on the implant with

the driver tool. Once fully engaged, unscrew the implant from the vial by rotating counterclockwise.

Step 3B - Loading the Driver • Carefully lift the implant out of the vial.

• Use caution when bringing implant to the surgical site.

OCTAGON Implant Placement ProtocolPlacing Implant Into Osteotomy

Step 1 - Placement Setup and Speed*

• With the OCTAGON Dental Implant attached to the driver tool, insert the implant into the prepared osteotomy using an implant placement speed of 15rpm and a maximum insertion torque of 35 N-cm.

• If the implant does not seat at 35 N-cm, back the implant out of the osteotomy, place the implant back into the sterile vial, then refer to the dense bone site preparation protocol (page 22).

Step 2 - Seating the Implant• Drive the implant until fully seated, leaving the bottom of

the polished collar flush with the crest of the bone ridge. Do not exceed 35 N-cm.

• CAUTION: Avoid using reverse rotations (counterclockwise) to correct vertical position, as this can decrease primary stability.

Step 3 - Disengaging Implant Driver• After placement, disengage the hand or contra-angle

implant driver tool from the implant by pulling off the tool in a straight upward direction.

(Protocol shown placing a Ø4.1mm x 12mm length Regular Platform Implant)

*External irrigation may be used to minimize heating during this process.

3B

21

1 2

3

3A

Page 26: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem24

OCTAGON Implant Placement ProtocolSingle-Stage Healing Option

Step 1 and 2 - Healing Cap

• Using one of the octagon screwdrivers, place the appropriate healing cap into the implant using the recommended seating torque of 15 N-cm and secure tightly into place.

Step 3 - Closing Tissue• Suture the tissue around the healing cap using

standard surgical protocols.

OCTAGON Implant Placement ProtocolRemoving Fixture-Mount

Step 1 and 2 - Loosing the Fixture-Mount• Use the holding key to engage the hexagon of the

fixture-mount to keep the implant from turning.

• Use the ratchet or contra-angle driver tool to turn screw counterclockwise to release fixture-mount from the implant.

Step 3 - Disengaging Fixture-Mount• Disengage the fixture-mount from the implant by

pulling off the driver tool and fixture-mount in a straight upward direction.

3

1 2

1 2

3

Page 27: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 25

i n f i n i t y OCTAGON Prosthetic Protocol

OCTAGON Implant Prosthetic ProtocolSolid Abutment Impression Technique - Closed Tray

Step 1 - Removing the Healing Cap or Cover Screw

• Using one of the octagon screwdrivers, remove the healing cap or cover screw from the implant.

Step 2 - Seating Solid Abutment• Seat the solid abutment with one of the solid abutment drivers.

• Place torque-wrench over the solid abutment driver and torque the solid abutment into the implant at 35 N-cm.

Step 3 - Placement of Impression Cap

• Push the impression cap over the solid abutment, and onto the implant shoulder, until it snaps into place.

• Check if impression cap is seated correctly by gently turning it on the implant. Impression cap should rotate smoothly on the implant.

Step 4 - Inserting Positioning Cylinder• Align the flat side of the appropriate positioning cylinder with the

flat side of the abutment.

• Push down the positioning cylinder over the abutment and through the impression cap.

• Make sure the positioning cylinder is flat and flushed against the impression cap, leaving no gap.

Step 5 - Impression Preparation

• Using impression material, encase the impression cap, position cylinder and solid abutment.

Step 6 - Take Impression• Place the loaded impression tray into the mouth, apply pressure,

and allow impression material to set.

• Send impression to laboratory.

Step 7 - Temporary Process• A temporary crown can be made and cemented to the prepped

abutment or left in place while the final prosthetic is being made.

21

3

6

7

5

4

Page 28: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem26

OCTAGON Implant Prosthetic ProtocolImplant Level Impression Technique - Closed Tray

21

4

6

3

5

7

Step 1 - Removing the Healing Cap or Cover Screw

• Using one of the octagon screwdrivers, remove the healing cap or cover screw from the implant.

Step 2 - Placement of Impression Cap

• Push the impression cap onto the implant shoulder, until it snaps into place.

• Check if impression cap is seated correctly by gently turning it on the implant. Impression cap should rotate smoothly on the implant.

Step 3 and 4 - Inserting Positioning Cylinder• Push down the positioning cylinder through the

impression cap.

• Make sure the positioning cylinder is flat and flush against the impression cap, leaving no gap.

Step 5 - Impression Preparation

• Using impression material, encase the impression cap and position cylinder.

Step 6 - Take Impression• Place the loaded impression tray into the mouth,

apply pressure, and allow impression material to set.

• Send impression to laboratory.

Step 7 - Replace Healing Cap• Clean the implant area and healing cap.

• Re-seat the healing cap with a hand screwdriver using the recommended seating torque of 15 N-cm.

Page 29: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 27

OCTAGON Implant Prosthetic ProtocolImplant Level Impression Technique - Open Tray

Step 1 - Removing the Healing Cap or Cover Screw

• Using one of the hand screwdrivers, remove the healing cap or cover screw from the implant.

Step 2 and 3 - Placing the Open Tray Impression Transfer• Seat the open tray transfer with transfer retaining screw

using one of the hand screwdrivers.

Step 4 - Prepare An Opening in Tray• Mark and then cut a Ø5-10mm opening in the top of

the impression tray at the exact area where the transfer will protrude.

Step 5 - Impression Preparation

• Using impression material, encase the transfer.

Step 6 - Take Impression

• Place the loaded impression tray into the mouth, apply pressure, and allow both impression materials to set.

Step 7 - Removing Tray and Transfer• Using one of the hand screwdrivers, carefully remove just the

retaining screw through the access hole, leaving the open tray transfer in the impression.

• Once impression has set, passively remove the impression with the remaining impression transfer embedded.

• Send the impression along with the laboratory components to the dental laboratory for model fabrication.

Step 8 - Replace Healing Cap• Clean the implant area and healing cap.

• Re-seat the healing cap with a hand screwdriver using the recommended seating torque of 15 N-cm.

2

3

1

4

8

5

7

6

Page 30: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem28

OCTAGON Implant Prosthetic ProtocolLOCATOR® Abutment

Step 1 - Removing the Healing Cap or Cover Screw

• Using one of the hand screwdrivers, remove the healing cap or cover screw from the implant.

Step 2 - Placing the LOCATOR® Abutment• Seat the LOCATOR Abutment by hand using

finger pressure.

Step 3 - Torque the LOCATOR® Abutment• Once seated on the implant, torque the LOCATOR

abutment to 30 N-cm using the LOCATOR Torque Wrench Driver (sold separately, part # 206-8914).

Step 4 - Impression Preparation• Place the LOCATOR impression transfers onto the

abutments.

Step 5A, 5B, 5C - Take Impressions

• Using impression material, cover the transfers.

• Place the loaded impression tray into the mouth, apply pressure, and allow impression material to set.

• Remove impression and send along with laboratory components to the laboratory.

5B

5C

5A

43

1 2

Page 31: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 29

A – UNSUCCESSFUL PLACEMENT FAILURE

ACE will replace, with an identical implant, any infinity implant that could not be placed at time of surgery for any reason.

The process will be as follows:

• The Customer Service Department is notified of the failure.• A Return Merchandise Authorization (RMA) is prepared by the

Customer Service Department and sent to the customer.• An identical implant will be sent and billed to the customer.• The customer will use the provided RMA to send ACE the unsuccessful

implant in a sterile package.• Upon receipt of the unsuccessful implant, ACE will credit the

billed implant replacement.

B – POST-PLACEMENT; PRE-LOADING FAILURE

ACE will replace any infinity implant that for any reason fails Post-Placement; Pre-Loading.

ACE will provide the following:

1. An identical infinity implant to the failed implant.2. A $150 product credit on any ACE regenerative products, sutures

or instrumentation needed to graft the site.** In addition to the return process outlined above in “A”, the surgeon

will need to provide an x-ray showing the compromised site.

C – POST-LOADING FAILURES

ACE will replace any infinity implant that fails for any reason Post-Loading.

ACE will provide the following:

1. An identical infinity implant.2. infinity restorative components to match the infinity implant.3. In the event of a defect corresponding to the failed implant site,

a $150 product credit will be provided on any ACE regenerative products, sutures or instrumentation needed to graft the site.

4. One additional infinity implant and corresponding restorative components to the restoring dentist or the equivalent product value.

The return process is outlined above in “A”.

D – IMPLANT FAILURES WITH OTHER MANUFACTURER’S IMPLANTS AND infinity RESTORATIVE COMPONENTS

In the event that another manufacturer’s implant fails and has an infinity restorative components used in the restoration ACE will provide the following:

1. ACE will replace the restorative components.

2. ACE will provide the surgeon with a similar infinity implant as to the original failed implant.

The return process is outlined above in “A”.

Please contact your ACE representative with any warranty related issues.ACE Surgical Supply Co., Inc.1034 Pearl Street, Brockton, MA 02301 - USATel. 1-800-441-3100 Fax 1-800-583-3150www.acesurgical.com

The infinity Dental Implant System warranty program is designed to support all clinicians involved with an implant that may fail. This warranty will address all aspects of the procedure as long as either an infinity implant or restorative component was used in conjunction with the failed dental implant.

This warranty addresses the following:

A – An Unsuccessful Placement Failure

B – A Post-Placement and Pre-Loading Failure

C – A Post-Loading Failure

D – A Post-Loading Failure utilizing a different implant manufacturer but using ACE Restorative components.

i n f i n i t y Implant Warranty

Denta l Imp lant Sys tems

Page 32: PROOF DATE: Feb 4 · 2016. 2. 17. · the implant, which allows for easy removal once the cap has been removed. IMPLANT TRANSFER Titanium support transfer and transfer screw is included

ACE SURGICAL SUPPLY CO., INC.

1034 Pearl Street, Brockton, MA 02301 - USA

1-800-441-3100 • www.acesurgical.com

79 | 01-15A