443 06 2300 00 12/3/15Specifications subject to change without notice.
NAHA01201NG
INSTALLATION INSTRUCTIONSPROPANE GAS to NATURAL GAS LOW−CAPACITY
GAS CONVERSION KITCondensing Gas Furnaces, 26,000 BTUH Only
F9MXE0261410, G9MXE0261410, N9MSE0261408
CERTIFIED
NOTE: Read the entire instruction manual before startingthe installation.
SAFETY CONSIDERATION
FIRE, EXPLOSION, ELECTRICAL SHOCK, ANDCARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personalinjury or death.
This conversion kit shall be installed by a qualifiedservice agency in accordance with the manufacturer’sinstructions and all applicable codes andrequirements of the authority having jurisdiction. If theinformation in these instructions is not followedexactly, a fire, explosion, or production of carbonmonoxide could result causing property damage,personal injury, or loss of life. The qualified serviceagency is responsible for the proper installation of thisfurnace with this kit. The installation is not proper andcomplete until the operation of the convertedappliance is checked as specified in themanufacturer’s instructions supplied with the kit.
! WARNING
LE FEU, L’EXPLOSION, CHOC ELECTRIQUE,ET MONOXYDE DE CARBONEEMPOISONNER
Cette trousse de conversion doit être installée par unservie d’entretien qualifié, selon les instructions dufabricant et selon toutes les exigences et tous lescodes pertinents de l’autorité compétente.Assurezvous de bien suivre les instructions danscette notice pour réduire au minimum le risqued’incendie, d’explosion ou la production de monoxydede carbone pouvant causer des dommagesmatériels, de blessure ou la mort. Le serviced’entretien qualifié est responsable de l’installation decette trousse. L’installation n’est pas adéquate nicomplète tant que le bon fonctionnement de l’appereilconverti n’a pas été vérfié selon les instructions dufabricant fornies avec la trousse.
! AVERTISSEMENT
Installing and servicing heating equipment can behazardous due to gas and electrical components. Onlytrained and qualified personnel should install, repair, orservice heating equipment.Untrained personnel can perform basic maintenancefunctions such as cleaning and replacing air filters. Trainedservice personnel must perform all other operations. Whenworking on heating equipment, observe precautions in theliterature, on tags, and on labels attached to or shippedwith the unit, and other safety precautions that may apply.Follow all safety codes. In the United States, follow allsafety codes including the current edition of the NationalFuel Gas Code (NFGC) NFPA No. 54/ANSI Z223.1. InCanada, refer to the current edition of the NationalStandard of Canada, Natural Gas and Propane InstallationCodes (NSCNGPIC), CAN/CSA−B149.1 and .2. Wearsafety glasses and work gloves. Have a fire extinguisheravailable during start−up, adjustment steps, and servicecalls.Recognize safety information. This is the safety−alert
symbol . When you see this symbol on the furnace andin instructions or manuals, be alert to the potential forpersonal injury. Understand the signal words DANGER,WARNING, CAUTION and NOTE. The words DANGER,WARNING, and CAUTION are used with the safety alertsymbol. DANGER identifies the most serious hazardswhich will result in severe personal injury or death.WARNING signifies a hazard which could result inpersonal injury or death. CAUTION is used to identifyunsafe practices which may result in minor personal injuryor product and property damage. NOTE is used tohighlight suggestions which will result in enhancedinstallation, reliability, or operation.
INTRODUCTION
FIRE, EXPLOSION, ELECTRICAL SHOCK ANDCARBON MONOXIDE POISONING HAZARD
Failure to follow instructions could result in personalinjury, death or property damage.
Improper installation, adjustment, alteration, service,maintenance, or use can cause carbon monoxidepoisoning, explosion, fire, electrical shock, or otherconditions, which could result in personal injury ordeath. Consult your distributor or branch forinformation or assistance. The qualified installer oragency must use only factory−authorized kits oraccessories when servicing this product.
! WARNING
2 443 06 2300 00Specifications subject to change without notice.
FIRE, EXPLOSION, ELECTRICAL SHOCKHAZARD
Failure to follow this warning could result in personalinjury, death or property damage.
Gas supply MUST be shut off before disconnectingelectrical power and proceeding with conversion.
! WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSIONHAZARD
Failure to follow this warning could result in personalinjury, death or property damage.
Before installing, modifying, or servicing system, mainelectrical disconnect switch must be in the OFFposition and install a lockout tag. There may be morethan one disconnect switch. Lock out and tag switchwith a suitable warning label. Verify proper operationafter servicing.
! WARNING
This instruction covers the installation of gas conversion kitPart No. NAHA01201NG to convert the F9MXE, G9MXEand N9MSE 26,000 BTUH low capacity furnaces fromPropane gas usage to natural gas usage.
DESCRIPTION AND USAGESee Table 1 for kit contents. This kit is designed for use inthe furnaces listed in Table 2. To accommodate manydifferent furnace models, more parts are shipped in kit thanwill be needed to complete conversion. When installation iscomplete, discard extra parts.
Table 1 – NAHA01201NG ContentsCOMPONENT
NUMBERQTY DESCRIPTION
1188172 1VALVE CVRSN KIT W/R SPRING
F92-1035
1186370 7 PARTS ASSY #42
1186371 7 PARTS ASSY #43
1186372 7 PARTS ASSY #44
342017-701 1 LABEL KIT
319965-481 1 LABEL,SHIPPING
NAHA01201LP 1 INSTR GAS CVRSN LP TO NAT
1175472 1 PLUG, PIPE
Table 2 – Condensing FurnacesMODEL NUMBERS BEGINNING WITH:
F9MXE G9MXE N9MXE
26,000 Input Only
INSTALLATION1. Set room thermostat to lowest setting or “OFF”2. Remove outer doors3. Disconnect power at external disconnect, fuse or
circuit breaker.4. Turn off gas at external shut−off or gas meter.5. Remove outer doors and set aside.6. Turn electric switch on gas valve to OFF.
MANIFOLD/ORIFICE/BURNERREMOVAL
UNIT OPERATION HAZARD
Failure to follow this caution may result in unitdamage or improper operation.
Label all wires prior to disconnection when servicingcontrols.
CAUTION!
D’EQUIPEMENT D’OPERATION
Toute erreur de câblage peut être une source dedanger et de panne.
Lors des opérations d’entretien des commandes,étiqueter tous les fils avant de les déconnecter.
PRUDENCE!
1. Disconnect the gas pipe from gas valve and removepipe from the furnace casing. See Figure 1.
NOTE: Use a back−up wrench on the gas valve to preventthe valve from rotating on the manifold or damaging themounting to the burner box. See Figure 2 and Figure 3.
2. Disconnect the connector harness from gas valve.Disconnect wires from Hot Surface Igniter (HSI) andFlame Sensor. Disconnect the two wires from theLow Gas Pressure Switch (LGPS) located on thegas valve.
3. Support the manifold and remove the 4 screws thatsecure the manifold assembly to the burner box andset aside.
4. Note the location of the green/yellow wire groundwire for re−assembly later. See Figure 2.
A12528
RATING PLATE NOT SHOWN(LOCATED ON BLOWER DOOR)
GAS VALVEMAIN LIMIT SWITCH(BEHIND GAS VALVE)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
ELECTRICAL JUNCTIONBOX (IF REQUIRED, LOCATION MAY VARY)
OPERATING INSTRUCTIONSNOT SHOWN (LOCATED ONMAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).
FURNACECONTROLBOARD
MANUAL RESETROLLOUT SWITCH
FLAMESENSOR
MANUAL RESETROLLOUT SWITCH
GAS BURNER
HOT SURFACEIGNITER
INDUCER MOTORASSEMBLY
BLOWER ANDMOTOR
CAPACITOR/POWER CHOKE(IF USED)
BLOWER DOORSAFETY SWITCH
IGNITERTRANSFORMER
Representative drawing only, some models may vary in appearance.
Figure 1 − Representative Furnace Drawing
443 06 2300 00 3Specifications subject to change without notice.
5. Slide one−piece burner assembly out of slots onsides of burner box.
6. Remove the flame sensor from the burner assembly.See Figure 3.
7. Remove the orifices from the manifold and discard.Orifice
Connect Green/Yellowground wire here
Manifold
Gas Valve
Gas valve must be installed onmanifold with minimum engagement of6 threads Cross threading is not
Indicated surfacesto be 90 ˚+ or -2˚
CLGas valve is parallel to manifold within + or - 3˚
A11407
Figure 2 − Manifold Assembly
FLAME SENSOR(BELOW BURNER)
FLAME ROLLOUTSWITCH
BRACKET, IGNITERIGNITERBURNER SUPT. ASSY
BURNER ASSY
A11403
Figure 3 − Burner Assembly
ORIFICE SELECTION/DERATE
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unitdamage.
DO NOT re−drill burner orifices. Improper drilling mayresult in burrs, out−of−round holes, etc. Obtain neworifices if orifice size must be changed. (SeeFigure 4.)
CAUTION!
BURNER ORIFICE BURNER
ORIFICE
A96249
Figure 4 − Burner Orifice
Determine natural gas orifice size and manifold pressurefor correct input at installed altitude by using Table 3.
1. Obtain yearly heat−value average (at installedaltitude) for local gas supply.
2. Obtain yearly specific−gravity average for local gassupply.
3. Find installation altitude in Table 3.NOTE: For Canada altitudes of 2000 to 4500 ft., useU.S.A. Altitudes of 2001 to 3000 ft. In Table 3.
4. Find closest natural gas heat value and specificgravity in Table 3.
5. Follow heat−value line and specific−gravity line topoint of intersection to find orifice size and manifoldpressure settings.
Furnace gas input rate on furnace rating plate is forinstallations at altitudes up to 2000 ft. (610 M).In the U.S.A.; the input rating for altitudes above 2000 ft.(610 M) must be reduced by 2 percent for each 1000 ft.(305 M) above sea level.In Canada, the input rating must be derated by 5 percentfor altitudes of 2000 ft. to 4500 ft. (610 M to 1372 M) abovesea level.The Conversion Kit Rating Plate accounts for high altitudederate.
INSTALL ORIFICES1. Install main burner orifices. DO NOT use Teflon
tape. Finger−tighten orifices at least one full turn toprevent cross−threading, then tighten with wrench.
2. There are additional size orifices for different heatcontent gases. Discard extra orifices.
NOTE: DO NOT reinstall the manifold at this time.
REMOVE MIXER SCREWS FROMTHE BURNERSNOTE: Each burner contains a mixer screw that must beremoved. Refer to Figure 5 for the mixer screw location.
1. Remove the mixer screws from the burners.NOTE: It is not necessary to plug the hole in the burnerwhen the mixer screws are removed.
4 443 06 2300 00Specifications subject to change without notice.
1.9”(48.76 mm)
1.8”(46.96 mm)
Location of mixer screwthat must be removed
A11501
Figure 5 − Mixer Screw Location
REINSTALL BURNER ASSEMBLYTo reinstall burner assembly:
1. Attach flame sensor to burner assembly.2. Insert one-piece burner in slot on sides of burner
box and slide burner back in place.3. Reattach HSI wires to HSI.4. Verify igniter to burner alignment. See Figure 6 &
Figure 7.
2-1/2-in.(64.4)
1-1/4-in.(31.8)
A11405
Figure 6 − Igniter Position − Back View
2 − in.
(2.5 mm
3/8 − in.
3/16− in.
, +0.8 -1.5)
(50 mm)
(9.6 mm)
(4.6 mm)
3/32− in., +1/32 -3/64-in.
A12932
Figure 7 − Igniter Position − Side View
PRE−ADJUST GAS VALVE
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unitdamage
The gas valve must be converted and pre−adjustedbefore operating on natural gas. If left this way,sooting and corrosion will occur leading to early heatexchanger failure.
CAUTION!
FIRE, EXPLOSION, ELECTRICAL SHOCKHAZARD
Failure to follow this warning could result in personalinjury, death or property damage.
Gas supply MUST be shut off before disconnectingelectrical power and proceeding with conversion.
! WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSIONHAZARD
Failure to follow this warning could result in personalinjury, death or property damage.
Before installing, modifying, or servicing system, mainelectrical disconnect switch must be in the OFFposition and install a lockout tag. There may be morethan one disconnect switch. Lock out and tag switchwith a suitable warning label. Verify proper operationafter servicing.
! WARNING
NOTE: The green labeled Low−Capacity single−stagevalve DOES NOT need to have the regulator springreplaced in the gas valve. The regulator in the gas valvemust be pre−adjusted to convert from propane to naturalgas applications. An identical regulator spring is includedin the kit to be used in the event the factory spring isunnecessarily removed and misplaced during the propaneconversion. The regulator spring is red in color todistinguish it from other regulator springs.
1. Refer to Figure 8.2. Be sure gas and electrical supplies to furnace are
off.3. Remove cap that conceals the adjustment screw for
the gas−valve regulator. (See Figure 8.)4. Turn the regulator adjustment screw one (1) full turn
out. This will decrease the manifold pressure closerto the natural gas set point.
5. DO NOT install the brass regulator seal cap at thistime.
6. If the red regulator spring is removed, install thespring and the adjustment screw.
443 06 2300 00 5Specifications subject to change without notice.
7. Turn the adjusting screw clockwise (in) 10.5 fullturns. This will increase the manifold pressure closerto the natural gas set point. (See Figure 8.)
8. DO NOT install regulator seal cap at this time.
ON/OFF Switch
Regulator Seal Cap
Regulator Adjustment underRegulator Seal Cap
1/2” NPT Outlet
1/8” NPT ManifoldPressure Tap
1/8” NPT InletPressure Tap
1/2” NPT Inlet
SINGLE-STAGE
Regulator Spring Red
Regulator AdjustmentScrew
Regulator Seal Cap
A150593
Figure 8 − Single−Stage Gas Valve
REMOVE LOW GAS PRESSURESWITCHNOTE: There are 2 ways that the Low Gas PressureSwitch (LGPS) could have been installed during theoriginal natural to Propane gas conversion.All 14 3/16-in (360 mm) Casings or Vent PassedBetween Inducer Assembly and Burner AssemblyIf the vent pipe passes between the inducer and burnerassembly, or the furnace is a 14 3/16-in. (360 mm) widecasing, the switch may have been installed as follows (SeeFigure 9).
1. Remove low gas pressure switch, brass street 90�elbow, brass Hex nipple, brass tee and black ironstreet 90� elbow from the gas valve inlet pressuretap. (See Figure 9.)
NOTE: Use pipe dope approved for use with Propanegas. DO NOT use Teflon tape.
2. Apply pipe dope sparingly to the 1/8−in. NPT pipeplug (provided in kit) and install in the 1/8−in tappedinlet−pressure tap opening in the gas valve. DONOT over−tighten. Check for gas leaks after gassupply has been turned on.
Brass Street Tee
Brass Hex Nipple
Brass Street 90
Low Gas Pressure Switch
Black Iron Street 90 Pointing
Inlet Pressure Tap with Plug
Re install pipe plugafter removal
L13F011
Figure 9 − Low Gas Pressure Switch Removal
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personalinjury, death, and/or property damage.
NEVER test for gas leaks with an open flame. Use acommercially available soap solution made specificallyfor the detection of leaks to check all connections. Afire or explosion may result causing property damage,personal injury or loss of life.
! WARNING
RISQUE D’EXPLOSION ET D’INCENDIE
Cet avertissement peut entraîner de la mort, desblessures et/ou des dégâts matériels.
Ne jamais examiner pour les fuites de gaz avec uneflamme vive. Utilisez plutôt un savon fait specifiquementpour la détection des fuites de gaz pour verifier tous lesconnections. Un incendie ou une explosion peutentrainer des dommages matériels, des blessures ou lamort.
! AVERTISSEMENT
Casings Wider Than 14 3/16-in. (360 mm) / Vent DoesNot Pass Between Inducer and Burner AssemblyIf the vent pipe does not pass between the inducer andburner assembly, or the furnace is wider than a 14 3/16-in.(360 mm) wide casing, remove the switch as follows (SeeFigure 10.):
1. Remove Low Gas Pressure Switch, brass street tee,brass nipple and brass street 90� elbow from thegas valve inlet pressure tap. See Figure 10.
NOTE: Use pipe dope approved for use with Propanegas. DO NOT use Teflon tape.
2. Apply pipe dope sparingly to the 1/8−in. NPT pipeplug (provided in kit) and install in the 1/8−in tappedinlet−pressure tap opening in the gas valve. DONOT over−tighten. Check for gas leaks after gassupply has been turned on.
L13F012
Figure 10 − Alternate Low Gas Pressure SwitchRemoval
INSTALL MANIFOLD1. Align the orifices in the manifold assembly with the
support rings on the end of the burner.2. Insert the orifices in the support rings of the burners.
Manifold mounting tabs should fit flush against theburner box.
6 443 06 2300 00Specifications subject to change without notice.
NOTE: If manifold does not fit flush against the burnerbox, the burners are not fully seated forward. Remove themanifold and check burner positioning in the burner boxassembly.
3. Attach the green/yellow wire and ground terminal toone of the manifold mounting screws. See Figure 2.
4. Install the remaining manifold mounting screws.5. Connect the wires to the flame sensor and hot
surface igniter.6. Connect the connector harness to gas valve.7. Rewire unit low pressure switch (LPS) as follows:
a. Trace one of the orange wires previouslydisconnected from the LGPS back to the NOterminals of the LPS.
b. Trace the other orange wire previouslydisconnected from the LGPS back to its spliceconnection with the yellow wire of the furnacewire harness. Disconnect and discard thisorange wire and the splice connection.
c. Connect the yellow wire of the furnace wireharness (see “b” above) to the NO terminal of theLPS.
d. Refer to the furnace wiring diagram to ensureproper location of wires.
NOTE: Use only Propane-resistant pipe dope. DO NOTuse Teflon tape.
8. Insert the gas pipe through the grommet in thecasing. Apply a thin layer of pipe dope to the threadsof the pipe and thread the pipe by into the gas valve.
NOTE: Use a back-up wrench on the gas valve to preventthe valve from rotating on the manifold or damaging themounting to the burner box.
9. With a back-up wrench on the inlet boss of the gasvalve, finish tightening the gas pipe to the gas valve.
10. Turn gas on at electric switch on gas valve.
CHECK INLET GAS PRESSURE
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unitdamage.
DO NOT operate furnace more than one minute tocheck inlet gas pressure, as conversion is notcomplete at this time.
CAUTION!
NOTE: This kit is to be used only when inlet gas pressureis between 4.5−in. W.C. and 13.6−in. W.C.
1. Verify manometer is connected to inlet pressure tapon gas valve. (See Figure 8.)
2. Turn on furnace power supply.3. Turn gas supply manual shutoff valve to ON
position.
FIRE, EXPLOSION, ELECTRICAL SHOCKHAZARD
Failure to follow this warning could result in personalinjury, death or property damage.
Gas supply MUST be shut off before disconnectingelectrical power and proceeding with conversion.
! WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSIONHAZARD
Failure to follow this warning could result in personalinjury, death or property damage.
Before installing, modifying, or servicing system, mainelectrical disconnect switch must be in the OFFposition and install a lockout tag. There may be morethan one disconnect switch. Lock out and tag switchwith a suitable warning label. Verify proper operationafter servicing.
! WARNING
4. Turn furnace gas valve switch to ON position.5. Jumper R−W thermostat connections on control.6. When main burners ignite, confirm inlet gas
pressure is between 4.5−in. W.C. and 13.6−in. W.C.7. Remove jumper across R−W thermostat
connections to terminate call for heat.8. Turn furnace gas valve switch to OFF position.9. Turn gas supply manual shutoff valve to OFF
position.10. Turn off furnace power supply.11. Remove manometer.12. Apply pipe dope sparingly to the 1/8−in. NPT pipe
plug and install in the 1/8−in. tapped inlet−pressuretap opening in the gas valve. DO NOT over−tighten.Check for gas leaks after gas supply has beenturned on.
CHECK FURNACE AND MAKEADJUSTMENTS
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personalinjury, death, and/or property damage.
NEVER test for gas leaks with an open flame. Use acommercially available soap solution made specificallyfor the detection of leaks to check all connections. Afire or explosion may result causing property damage,personal injury or loss of life.
! WARNING
RISQUE D’EXPLOSION ET D’INCENDIE
Cet avertissement peut entraîner de la mort, desblessures et/ou des dégâts matériels.
Ne jamais examiner pour les fuites de gaz avec uneflamme vive. Utilisez plutôt un savon fait specifiquementpour la détection des fuites de gaz pour verifier tous lesconnections. Un incendie ou une explosion peutentrainer des dommages matériels, des blessures ou lamort.
! AVERTISSEMENT
1. Be sure main gas and electric supplies to furnaceare off.
2. Remove 1/8-in. NPT pipe plug from manifoldpressure tap on downstream side of gas valve.
443 06 2300 00 7Specifications subject to change without notice.
3. Attach manometer to manifold pressure tap on gasvalve. (see Figure 8.)
4. Turn gas supply manual shutoff valve to ONposition.
5. Turn furnace gas valve switch to ON position.6. Check all threaded pipe connections for gas leaks.7. Turn on furnace power supply.
GAS INPUT RATE INFORMATIONSee furnace rating plate on blower door for input rate. Theinput rate for natural gas is determined by manifoldpressure and orifice size.Determine natural gas orifice size and manifold pressurefor correct input at installed altitude by using Table 3.
1. Obtain yearly heat−value average (at installedaltitude) for local gas supply.
2. Obtain yearly specific−gravity average for local gassupply.
3. Find installation altitude in Table 3.NOTE: For Canada altitudes of 2000 to 4500 ft., useU.S.A. Altitudes of 2001 to 3000 ft. in Table 3.
4. Find closest natural gas heat value and specificgravity in Table 3.
5. Follow heat−value line and specific−gravity line topoint of intersection to find orifice size and manifoldpressure setting.
Furnace gas input rate on rating plate is for installations ataltitudes up to 2000 ft. (610 M).In the U.S.A.; the input rating for altitudes above 2000 ft.(610M) must be reduced by 2 percent for each 1000 ft.(305 M) above sea level.In Canada; the input rating must be derated by 5 percentfor altitudes of 2000 ft. (610 M) to 4500 ft. (1372 M) abovesea level.The Conversion Kit Rating Plate accounts for high altitudederate.
8 443 06 2300 00Specifications subject to change without notice.
Table 3 – Orifice Size and Manifold Pressure Table26,000 BTUH ONLY
AVG. GASHEAT VALUE
AT ALTITUDE Orifice Manifold Orifice Manifold Orifice Manifold Orifice Manifold
(Btu/cu ft) No. Pressure No. Pressure No. Pressure No. Pressure
900 44 1.8 43 1.7 43 1.7 43 1.8
0 925 44 1.7 44 1.8 43 1.6 43 1.7
(0) 950 44 1.6 44 1.7 44 1.8 44 1.8975 44 1.6 44 1.6 44 1.7 44 1.7
to 1000 44 1.5 44 1.5 44 1.6 44 1.61025 44 1.4 44 1.5 44 1.5 44 1.6
2000 1050 44 1.3 44 1.4 44 1.4 44 1.5(610) 1075 44 1.3 44 1.3 44 1.4 44 1.4
1100 44 1.2 44 1.3 44 1.3 44 1.4
U.S.A. 800 43 1.7 43 1.8 43 1.8 42 1.6
2001 (611) 825 43 1.6 43 1.7 43 1.7 43 1.8
to 850 44 1.8 44 1.8 43 1.6 43 1.7
3000 (914) 875 44 1.7 44 1.7 44 1.8 44 1.8900 44 1.6 44 1.6 44 1.7 44 1.7
Canada 925 44 1.5 44 1.5 44 1.6 44 1.62001 (611) 950 44 1.4 44 1.5 44 1.5 44 1.6
to 975 44 1.3 44 1.4 44 1.4 44 1.54500 (1372) 1000 44 1.3 44 1.3 44 1.4 44 1.4
775 43 1.7 43 1.8 43 1.8 42 1.5
800 44 1.8 43 1.7 43 1.7 43 1.8
3001 825 44 1.7 44 1.8 44 1.8 43 1.7
(915) 850 44 1.6 44 1.7 44 1.7 44 1.8875 44 1.5 44 1.6 44 1.6 44 1.7900 44 1.4 44 1.5 44 1.5 44 1.6
4000 925 44 1.4 44 1.4 44 1.5 44 1.5(1219) 950 44 1.3 44 1.3 44 1.4 44 1.4
750 43 1.7 43 1.7 43 1.8 43 1.8
775 44 1.8 43 1.6 43 1.7 43 1.7
4001 800 44 1.7 44 1.7 44 1.8 43 1.6
(1220) 825 44 1.6 44 1.6 44 1.7 44 1.8850 44 1.5 44 1.5 44 1.6 44 1.7
to 875 44 1.4 44 1.5 44 1.5 44 1.65000 900 44 1.3 44 1.4 44 1.4 44 1.5
(1524) 925 44 1.3 44 1.3 44 1.4 44 1.4
725 43 1.7 43 1.7 43 1.8 43 1.8
5001 750 44 1.8 44 1.8 43 1.7 43 1.7
(1525) 775 44 1.7 44 1.7 44 1.8 44 1.8800 44 1.6 44 1.6 44 1.7 44 1.7825 44 1.5 44 1.5 44 1.6 44 1.6850 44 1.4 44 1.4 44 1.5 44 1.5
6000 875 44 1.3 44 1.3 44 1.4 44 1.4(1829) 900 44 1.2 44 1.3 44 1.3 44 1.4
675 43 1.8 43 1.8 42 1.5 42 1.6
6001 700 43 1.6 43 1.7 43 1.7 43 1.8
(1830) 725 44 1.7 44 1.8 43 1.6 43 1.7
750 44 1.6 44 1.7 44 1.7 44 1.8775 44 1.5 44 1.6 44 1.6 44 1.7
7000 800 44 1.4 44 1.5 44 1.5 44 1.6(2133) 825 44 1.3 44 1.4 44 1.4 44 1.5
850 44 1.3 44 1.3 44 1.4 44 1.4
* Orifice numbers shown in BOLD are factory-installed.
U.S
.A. O
nly
U.S
.A. O
nly
to
U.S
.A. O
nly
to
ORIFICE SIZE* AND MANIFOLD PRESSURE (IN WC) FOR GAS INPUT RATE(TABULATED DATA BASED ON 13,000 BTUH PER BURNER, DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL
ALTITUDERANGE
U.S
.A. a
nd C
anad
aU
.S.A
. and
Can
ada
U.S
.A. O
nly
ft (m)
SPECIFIC GRAVITY OF NATURAL GAS0.58 0.60 0.62 0.64
to
A150571
443 06 2300 00 9Specifications subject to change without notice.
Table 3 − Orifice Size and Manifold Pressure (in. w.c.) for Gas Input Rate (Continued)26,000 BTUH ONLY
650 43 1.7 43 1.8 42 1.5 42 1.6
7001 675 44 1.8 43 1.7 43 1.7 43 1.8
(2134) 700 44 1.7 44 1.8 44 1.8 43 1.7
725 44 1.6 44 1.7 44 1.7 44 1.8750 44 1.5 44 1.5 44 1.6 44 1.6
8000 775 44 1.4 44 1.4 44 1.5 44 1.5(2438) 800 44 1.3 44 1.4 44 1.4 44 1.4
825 44 1.2 44 1.3 44 1.3 44 1.4
625 43 1.7 43 1.8 43 1.8 42 1.6
8001 650 44 1.8 43 1.7 43 1.7 43 1.8
(2439) 675 44 1.7 44 1.8 44 1.8 43 1.6
700 44 1.6 44 1.6 44 1.7 44 1.7725 44 1.5 44 1.5 44 1.6 44 1.6
9000 750 44 1.4 44 1.4 44 1.5 44 1.5(2743) 775 44 1.3 44 1.3 44 1.4 44 1.4
9001 600 43 1.7 43 1.8 43 1.8 42 1.6
(2744) 625 44 1.8 43 1.6 43 1.7 43 1.7
650 44 1.7 44 1.7 44 1.8 44 1.8675 44 1.6 44 1.6 44 1.7 44 1.7
10000 700 44 1.4 44 1.5 44 1.5 44 1.6(3048) 725 44 1.3 44 1.4 44 1.4 44 1.5
* Orifice numbers shown in BOLD are factory-installed.
U.S
.A. O
nly
to
U.S
.A. O
nly
toU
.S.A
. Onl
y
to
ORIFICE SIZE* AND MANIFOLD PRESSURE (IN WC) FOR GAS INPUT RATE(TABULATED DATA BASED ON 13,000 BTUH PER BURNER, DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL
A150572
SET GAS INPUT RATE
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personalinjury, death, and/or property damage.
NEVER test for gas leaks with an open flame. Use acommercially available soap solution made specificallyfor the detection of leaks to check all connections. Afire or explosion may result causing property damage,personal injury or loss of life.
! WARNING
RISQUE D’EXPLOSION ET D’INCENDIE
Cet avertissement peut entraîner de la mort, desblessures et/ou des dégâts matériels.
Ne jamais examiner pour les fuites de gaz avec uneflamme vive. Utilisez plutôt un savon fait specifiquementpour la détection des fuites de gaz pour verifier tous lesconnections. Un incendie ou une explosion peutentrainer des dommages matériels, des blessures ou lamort.
! AVERTISSEMENT
1. Make sure the gas supply is turned off to the furnaceand at the electric switch on the gas valve.
2. Remove the 1/8 inch NPT plug from the outletpressure tap on the gas valve.
3. Connect a manometer to the outlet pressure tap ongas valve.
4. Turn on furnace power supply.
5. Turn gas supply manual shutoff valve to ONposition.
6. Turn furnace gas valve switch to ON position.7. Jumper R and W thermostat connections to call for
heat. (See Figure 12.)8. Check manifold orifices for gas leaks when main
burners ignite.9. Adjust gas manifold pressure. Refer to Table 3.
10. Remove cap that conceals the gas valve regulatoradjustment screw.
11. Turn adjusting screw counterclockwise (out) todecrease manifold pressure or clockwise (in) toincrease manifold pressure.
12. Replace gas valve regulator seal cap.13. Verify manifold pressure is correct. Refer to Table 3.
NOTE: Gas valve regulator seal cap MUST be in placewhen checking input rate. When correct input is obtained,main burner flame should be clear blue, almost transparent(See Figure 11). Be sure regulator seal cap is in placewhen finished.
14. Remove jumper across R and W thermostatconnections to terminate call for heat.
15. Turn furnace gas valve control switch or controlknob to OFF position.
16. Turn off furnace power supply.17. Remove manometer and reinstall manifold pressure
tap plug.18. Turn furnace gas−valve switch to ON position.19. Turn on furnace power supply.20. Set room thermostat to call for heat.21. Check pressure tap plug for gas leaks when main
burners ignite.
10 443 06 2300 00Specifications subject to change without notice.
22. Check for correct burner flame.23. After making the required manifold pressure
adjustments, check and adjust the furnacetemperature rise per the furnace installationinstructions.
CHECKOUT1. Observe unit operation through 2 complete heating
cycles.2. See Sequence of Operation in furnace Installation,
Start−Up, and Operating Instructions.3. Set room thermostat to desired temperature.
Burner Flame
Burner
ManifoldA11461
Figure 11 − Burner Flame
ÏÏÏÏÏÏÏÏÏÏÏÏ
HEATOFF−DELAY
COMPONENT TESTTERMINAL
P1 − LOW VOLTAGE MAINHARNESS CONNECTOR
TRANSFORMER 24−VACCONNECTIONS
P2−HOT SURFACE IGNITOR (HSI) & INDUCERMOTOR (IND) CONNECTOR
115 VAC(L1) LINEVOLTAGECONNECTION
SPARE1
COM/BLUE
115−VAC (L2) NEUTRALCONNECTIONS
24−V THERMOSTATTERMINALS
HUMIDIFIER TERMINAL(24−VAC 0.5 AMP MAX)
3−AMP FUSE
LED OPERATION &DIAGNOSTIC LIGHT
24VAC/RED
BLOWER SPEEDSELECTION TERMINALS
HUM
XFMR
HUMIDIFIERTERMINAL115−VAC
120 180
90 150
SPARE2
J2 JUMPER
J2
HUM24VAC
BLW
SPARE1 SPARE2
L2
NE
UT
RA
L
EAC 1 AMP
IND HSI
P2
L1
SPARE3
SPARE3
P1
1−AMP@115VAC
L13F013
Representative drawing only, some models may vary in appearance.
Figure 12 − Single−Stage Furnace Control
LABEL APPLICATION1. Fill in Conversion Responsibility Label 342017−205
and apply to blower door of furnace as shown. Date,name, and address of organization making thisconversion are required. See Figure 13.
2. Attach Conversion Rating Plate Label 342017−201to outer door of furnace. See Figure 13.
3. Apply Gas Control Conversion Label to gas valve:For single−stage gas valve apply label 342017−202
to gas valve. (DO NOT use 342017−203, which issimilar) Check for correct normal operatingsequence of the ignition system as described infurnace Installation, Start−Up, and OperatingInstructions.
4. Replace control access door, blower door and outerdoor of furnace.
443 06 2300 00 11Specifications subject to change without notice.
A150689
Figure 13 − Conversion Kit Labels