proposed alterations & additions to taung skull … · cut aerolite out around trap doors. fix...

1
IE RE D i a . 11 0 m m p . v . c . s o i l p i p e w i t h m i n . 1 : 1 0 0 f a l l t o s e p t i c t a n k GULLY wc wc IE IE IE IE RE IE RE GULLY IE IE D/SSteel sink IE RE IE GULLY TRAP RE IE IE Dia. 110mm p.v.c. soil pipe with min.1:100 fall to septic tank Dia. 110mm p.v.c. soil pipe with min.1:100 fall to septic tank Vent pipe fitted with 2-way anti-vac vent valve 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 100 000 T.O.Uffl/ Surface bed NGL 105 970 Apex of highest roof 102 125 U.S.Conc. lintol. 104 340 Apex of toilet roof Apex of toilet roof 100 000 T.O.Uffl/ Surface bed NGL NGL 104 960 U.S.Window lintol. 105 970 Apex of highest roof 100 000 T.O.Uffl/ Surface bed 101 900 U.S.Conc. lintol. 104 960 U.S.Window lintol. 105 970 Apex of highest roof 102 125 U.S.Window lintol. 102 125 U.S.Window lintol. 100 000 T.O.Uffl/ Surface bed NGL NGL 104 960 U.S.Conc. lintol. 105 970 Apex of highest roof 100 000 T.O.Uffl/ Surface bed 104 960 U.S.Conc. lintol. 105 970 Apex of highest roof 102 125 U.S.Window lintol. 102 125 U.S.Window lintol. 104 340 Apex of toilet roof Apex of toilet roof 100 000 T.O.Uffl/ Surface bed NGL NGL 100 000 T.O.Uffl/ Surface bed 106 040 Apex of highest roof 102 125 U.S.Conc. lintol. 102 125 U.S.Conc. lintol. 102 380 U.S.of Ceiling 102 380 U.S.of Ceiling 103 145 U.S Timber Beam 103 145 U.S Timber Beam 100 680 T.O.Rock Col. 100 680 T.O.Rock Col. NGL 100 000 T.O.Uffl/ Surface bed 102 125 U.S.Conc. lintol. 102 380 U.S.of Ceiling 103 380 Apex of toilet roof 100 680 T.O.Rock Cladding 106 040 Apex of highest roof NGL 100 000 T.O.Uffl/ Surface bed 101 900 U.S.Conc. lintol. 102 380 U.S.of Ceiling dpc dpc dpc dpc dpc dpc 16440 3375 1215 300 11250 300 230 2915 230 460 5270 460 4600 460 1650 3620 1800 115 1000 16440 3375 1515 6190 5060 300 230 2915 230 460 5270 460 4600 460 450 5290 450 1800 115 1000 15300 2300 3570 4290 3240 1150 450 300 450 1850 460 3110 230 1800 230 1800 230 2780 460 1150 15300 2300 11100 1600 300 450 1850 460 3420 460 2980 460 2860 460 1150 450 230 1100 230 110 460 110 460 110 3200 110 3400 110 110 2080 110 920 110 Proffice Building, 23 Corridor Crescent, Route N4 Business Park, Ben Fleur Ext 11 Post: P.O. Box 543, Emalahleni, 1035 Tel: 013-653 6321 / 653 6305 Fax: 086 567 5564 Email: [email protected] PRINCIPAL AGENT SIGNATURE: DEPARTMENT'S SIGNATURE: ARCHITECTS SIGNATURE: No: Date: Notes: Drawn: COPYRIGHT RESERVED COPYRIGHT NOTICE COPYRIGHT @ 2017- Bakopane Architects cc Copyright subsists in this drawing. The person or entity whose name appears in the tile block of this drawing, is hereby granted a non-exclusive licence to use, display, print and/ or reproduce this drawing to the extend necessary to carry out and complete the project described in the title block of this drawing. This licence in respect of the copyright is expressly limited as aforesaid and the person and / or entity referred to above shall not be entitled to grant sub-licences in respect of the copyright in this drawing to any other entity. This licence confers no ownership rights in the copyright vesting in the drawing and this drawing and the copyright subsisting therein will, at all times, remain the property of Bakopane Architects cc. Any unauthorised reproduction, publication, transmission, adaption and/or inclusion of this drawing in a cinematograph film or television broadcast is an act of copyright infringement which will render the doer of the act liable for civil law copyright infringement and may in certain circumstances render the doer liable to criminal prosecution. Requests and enquiries concerning this drawing and the rights subsisting therein should be addressed to the copyright owner. DRG. SIZE ORIGINAL REV. 01 A1 GENERAL NOTES: 1. Check all measurements,levels and details on site before commencement with work. 2. Refer any discreptancies to architect 3. All work to be done in accordance with SANS-10400 4. Nothing to be scaled from drawing: request measurement from architect 5. Architect's & engineer's drawings to be read together 6. Drawing to be used for intention as mentioned in Drawing description. TITLE: PROPOSED ALTERATIONS & ADDITIONS TO TAUNG SKULL HERITAGE SITE FOR NORTH-WEST RURAL, ENVIRONMENTAL & AGRICULTURE DEPARTMENT PROVINCE OF NORTH-WEST DRG No.: TAUNG - 42017 - ARC - SC01 SCALE: 1/100/20 CLIENTS SIGNATURE: DRAWING DESCRIPTION: Stone Cottage Floor plans, Elevations, Sections & Typical Detail. CEILING: Everite Nutec 6mm thick plain ceiling boards SANS 9001:2000 carrying SANS 803:2005 mark, fixed smooth face down with joints finished with Bishoff strips. Boards to be nailed to 38x114mm beam & 38x38mm SA Pine brandering (structural grade) @ max 400mm c/c in one direction. Apply one coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards. Color to be verified by architect. All to manufacturers specs & details. 1 2 1 2 1 1 1 2 1 Kitchen patio Entrance patio 1 2 1 Entrance patio Entrance patio Kitchen patio 1 2 Kitchen patio Kitchen Reception Waiting area Entr. patio Gents Toil Kitchen Boardroom Lobby Rock walls Rock walls Rock walls Rock walls Rock walls Rock walls Rock cladding Rock cladding Rock cladding Rock walls Rock walls Void above ceiling Steel edge trim. Walk-through to Reception & waiting area WHB WC STOVE WORK-TOP ,VAAL' PEARL PARAPLEGIC SEMI CLOSE COUPLE SUITE PRODUCT CODE 7300SC. Vaal Sanitaryware vitreous china "Pearl Paraplegic" semi-close coupled 90° outlet open rim washdown pan and matching 9 litre cistern complete with lid, fitments, & purpose made C.P. side-flush lever (left or right). Supplied with purpose made thermoset seat and cover plate. 02 02 As per supplier 'VAAL' HIBISCUS BASIN PRODUCT CODE 702303 DESCRIPTION. Vaal Sanitaryware vitreous china 510 x 405mm rounded “Hibiscus” basin with three semi-punched tapholes (i.e. available in zero, one, two or three taphole configurations), integrated overflow, and chainstay hole through the centre semi-punched taphole. To be finished in white as per supplier. 'VAAL Accessories" (code 71511086) 205x160x90mm. Install accessories against brick or tiled wall with super-glue and seal with silicone sealant. 02 02 02 As per supplier 32mm stainless steel grab rail by specialists. As per supplier specifications. Varies 01 - WC No. Req. Specification 02 - WHB 03 - WHB TRAP & PLUG 04 - VALVE SYSTEM 06 - TOILET ROLL HOLDER PARAPLEGIC TOILET 05 - GRAB RAILS Scale 1:100 North Elevation Scale 1:100 South Elevation Scale 1:100 West Elevation Scale 1:100 East Elevation Scale 1:50 Section A - A Scale 1:50 Section B - B Scale 1:20 Typical Elev. Scale 1:20 Sect. C - C Scale: NTS Sanitary schedule New Purpose Made Oregon Pine vertical sliding sash, double glazed window, plugged & screwed into existing brick wall by Oregon pine specialist. Old World Concretes Type 6 window sill, size 340 x 85 x 1100mm long bed, bedded and jointed in Class II mortar and pointed on all exposed faces. Exisiting Rock walls Exisiting Rock wall Gundle® API A.T USB Green 3 layer 250μm damp proof course laid in wall joints, conforming to (SANS 952-1:2011 Type C) laid with minimum 150mm overlaps and sealed with Gunplas pressure sensitive tape. INSIDE COTTAGE AREA SCHEDULE: Area of existing cottage: 124.87 sq.m Area of main entr. patio : 19.63 sq.m Area of existing kitchen patio: 14.23 sq.m Total Area of existing cottage: 158.73 sq.m Area of additional ablutions: 18.25 sq.m Total combined Area of cottage: 176.98 double glazing double glazing double glazing double glazing Stove Ssteel d/sink Kitchen Frdg 1 2 1 2 Board rm. Waiting Area Reception Office 1 Office 2 Entrance patio Kitchen patio Floor mounted chairs 2.1m Overhead Floor mounted chairs Ladies Toil. Gents Toil. Whb Whb Wc Wc Passage Kitchen patio Lobby 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron 1m Paving apron porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish porcelain tiles finish Plaster & paint Plaster & paint Plaster & paint NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. Ridge cap as supplied by "Hulamin" Sisalation: Sheeting & purlins to have fixed Laminated aluminium, Sisalation®410 Reflective Foil Insulation with reinforced with fiberglass & flame retardant additives as per Manufacturers specifications. Lay 135mm Aerolite insulation (Non-combustible andClass 1 fire index rating) on the ceiling ensuring that it fits tightly between the tie beams. Aerolite should be cut 50mm more than distance between the tie beams. Cut Aerolite out around trap doors. Fix the cut section to the back of the trap door using a good quality contact adhesive. Wrap Aerolite around cold and hot water pipes ensuring that there is 10mm overlap. Secure the Aerolite using a cable tie at 300mm centres. K-value: 0.040 W/mK (ASTM C518) Everite Nutec 6mm thick plain ceiling boards, manufactured in accordance with SANS 9001:2000 carrying SANS 803:2005 mark, fixed smooth face down, to 38mm x 50mm hardwood battens at 600mm centres using 32 x 2,5mm serrated ceiling nails at 150mm centres, minimum of 12mm from edge of boards. Apply one coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards. Color as per architect. Finish off with NUTEC 19mm Wood cleat all round, where ceiling meets wall surfaces. New 25mm Screed of 30MPa strength, on existing concrete slab to fall at 1:100 away from the structure. Screed mixed at 4:1:1 ratio crusher sand: plaster sand: cement and finished smooth with a steel trowel. All concrete work to be inspected and approved by engineers. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. Gundle® API A.T USB Green 3 layer 250μm damp proof course laid in wall joints, conforming to (SANS 952-1:2011 Type C) laid with minimum 150mm overlaps and sealed with Gunplas pressure sensitive tape. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. 85mm reinforced concrete surfacebed, of min. strength 30MPa to Engineers Dets & specs. Existing footing Existing footing Existing footing Existing footing Existing footing Existing footing New 114x38mm THK SA Pine treated beams New 114x38mm THK SA Pine treated beams Everite Nutec 6mm thick plain ceiling boards, manufactured in accordance with SANS 9001:2000 carrying SANS 803:2005 mark, fixed smooth face down, to 38mm x 50mm hardwood battens at 600mm centres using 32 x 2,5mm serrated ceiling nails at 150mm centres, minimum of 12mm from edge of boards. Apply one coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards. Color as per architect. Finish off with NUTEC 19mm Wood cleat all round, where ceiling meets wall surfaces. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations. Overhangs to be 600mm maximum. Lay 135mm Aerolite insulation (Non-combustible andClass 1 fire index rating) on the ceiling ensuring that it fits tightly between the tie beams. Aerolite should be cut 50mm more than distance between the tie beams. Cut Aerolite out around trap doors. Fix the cut section to the back of the trap door using a good quality contact adhesive. Wrap Aerolite around cold and hot water pipes ensuring that there is 10mm overlap. Secure the Aerolite using a cable tie at 300mm centres. K-value: 0.040 W/mK (ASTM C518) d1 d2 d2 d3 d3 d3 d4 d5 d5 w1 w1 w1 w1 w3 w3 w2 w2 w2 w2 w3 w2 w3 w2 w1 w1 w1 w1 d1 d2 d2 w2 w2 d1 d2 d3 d3 d3 w2 w2 w3 d5 B B A A Scale 1:100 Ground level floor plan

Upload: others

Post on 26-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROPOSED ALTERATIONS & ADDITIONS TO TAUNG SKULL … · Cut Aerolite out around trap doors. Fix the cut section to the back of the trap door using a good quality contact adhesive

IE

RE

Dia. 110mm p.v.c. soil pipe with min.1:100 fall to septic tank

GULLY

wc wc

IEIE

IEIE

RE

IE

RE GULLY

IE

IE

D/SSteel sink

IE

RE

IE

GULLY TRAP

RE

IE

IE

Dia

. 110m

m p

.v.c

. so

il p

ipe w

ith

min

.1:1

00 f

all t

o s

ep

tic t

an

k

Dia. 110mm p.v.c. soil pipe with min.1:100 fall to septic tank

Vent pipe fitted with 2-way anti-vac vent valve

100 000T.O.Uffl/ Surface bed

NGL

105 970Apex of highest roof

102 125U.S.Conc. lintol.

100 000T.O.Uffl/ Surface bed

NGL

105 970Apex of highest roof

102 125U.S.Conc. lintol.

100 000T.O.Uffl/ Surface bed

NGL

105 970Apex of highest roof

102 125U.S.Conc. lintol.

100 000T.O.Uffl/ Surface bed

NGL

105 970Apex of highest roof

102 125U.S.Conc. lintol.

104 340Apex of toilet roof Apex of toilet roof

100 000T.O.Uffl/ Surface bed

NGLNGL

104 960U.S.Window lintol.

105 970Apex of highest roof

100 000T.O.Uffl/ Surface bed

101 900U.S.Conc. lintol.

104 960U.S.Window lintol.

105 970Apex of highest roof

102 125U.S.Window lintol.

102 125U.S.Window lintol.

100 000T.O.Uffl/ Surface bed

NGLNGL

104 960U.S.Conc. lintol.

105 970Apex of highest roof

100 000T.O.Uffl/ Surface bed

104 960U.S.Conc. lintol.

105 970Apex of highest roof

102 125U.S.Window lintol.

102 125U.S.Window lintol.

104 340Apex of toilet roof Apex of toilet roof

100 000T.O.Uffl/ Surface bed

NGLNGL

100 000T.O.Uffl/ Surface bed

106 040Apex of highest roof

102 125U.S.Conc. lintol.

102 125U.S.Conc. lintol.

102 380U.S.of Ceiling

102 380U.S.of Ceiling

103 145U.S Timber Beam

103 145U.S Timber Beam

100 680T.O.Rock Col.

100 680T.O.Rock Col.

NGL

100 000T.O.Uffl/ Surface bed

102 125U.S.Conc. lintol.

102 380U.S.of Ceiling

103 380Apex of toilet roof

100 680T.O.Rock Cladding

106 040Apex of highest roof

NGL

100 000T.O.Uffl/ Surface bed

101 900U.S.Conc. lintol.

102 380U.S.of Ceiling

dpcdpc

dpcdpcdpc

dpc

16440

3375 1215 300 11250 300

230 2915 230 460 5270 460 4600 460

1650 36201800 115 1000

16440

3375 1515 6190 5060 300

230 2915 230 460 5270 460 4600 460

450 5290 4501800 115 1000

1530

0

2300

3570

4290

3240

1150

450

300

450

1850

460

3110

230

1800

230

1800

230

2780

460

1150

1530

0

2300

1110

016

0030

0

450

1850

460

3420

460

2980

460

2860

460

1150

450

230

1100

230

110

460

110

460

110

3200

110 3400 110

110 2080 110 920 110

Proffice Building,23 Corridor Crescent,Route N4 Business Park,Ben Fleur Ext 11

Post: P.O. Box 543, Emalahleni, 1035Tel: 013-653 6321 / 653 6305Fax: 086 567 5564Email: [email protected]

PRINCIPAL AGENT SIGNATURE:

DEPARTMENT'S SIGNATURE:

ARCHITECTS SIGNATURE:

No: Date: Notes: Drawn:

COPYRIGHT RESERVED

COPYRIGHT NOTICECOPYRIGHT @ 2017- Bakopane Architects ccCopyright subsists in this drawing. The person or entitywhose name appears in the tile block of this drawing,is hereby granted a non-exclusive licence to use, display,print and/ or reproduce this drawing to the extendnecessary to carry out and complete the project describedin the title block of this drawing. This licence in respect ofthe copyright is expressly limited as aforesaid and the personand / or entity referred to above shall not be entitled to grantsub-licences in respect of the copyright in this drawing to anyother entity. This licence confers no ownership rights in thecopyright vesting in the drawing and this drawing and thecopyright subsisting therein will, at all times, remain theproperty of Bakopane Architects cc. Any unauthorised reproduction,publication, transmission, adaption and/or inclusion of thisdrawing in a cinematograph film or television broadcast is anact of copyright infringement which will render the doer of theact liable for civil law copyright infringement and may in certaincircumstances render the doer liable to criminal prosecution.Requests and enquiries concerning this drawing and the rightssubsisting therein should be addressed to the copyright owner.

DRG. SIZE

ORIGINAL

REV.01

A1

GENERAL NOTES:

1. Check all measurements,levels and details on site before commencement with work.2. Refer any discreptancies to architect3. All work to be done in accordance with SANS-104004. Nothing to be scaled from drawing: request measurement from architect5. Architect's & engineer's drawings to be read together6. Drawing to be used for intention as mentioned in Drawing description.

TITLE:

PROPOSED ALTERATIONS

& ADDITIONS TO TAUNG SKULL

HERITAGE SITE

FOR NORTH-WEST RURAL,

ENVIRONMENTAL &

AGRICULTURE DEPARTMENT

PROVINCE OF NORTH-WEST

DRG No.: TAUNG - 42017 - ARC - SC01

SCALE: 1/100/20

CLIENTS SIGNATURE:

DRAWING DESCRIPTION:

Stone Cottage Floor plans,Elevations, Sections &

Typical Detail.

CEILING: Everite Nutec 6mm thick plain ceiling boards SANS 9001:2000 carrying SANS 803:2005 mark,

fixed smooth face down with joints finished with Bishoff strips. Boards to be nailed to 38x114mm beam & 38x38mm SA Pine brandering (structural grade) @ max

400mm c/c in one direction. Apply one coat universal primer to all exposed nail heads before applying

two coats final paint color to ceiling boards.Color to be verified by architect.

All to manufacturers specs & details.

12

121 1 1

21

Kitchen

patio

Entrance

patio

121

Entrance

patio

Entrance

patioKitchen

patio

12

Kitchen

patio

KitchenReceptionWaiting area

Entr.

patio

Gents Toil

KitchenBoardroomLobby

Rock wallsRock walls

Rock wallsRock walls

Rock walls

Rock walls

Rock cladding

Rock cladding

Rock cladding

Rock walls

Rock walls

Voidaboveceiling

Steel edge trim. Walk-through

to Reception &

waiting area

WHB

WC

STOVE WORK-TOP

,VAAL' PEARL PARAPLEGIC SEMI CLOSE COUPLE SUITEPRODUCT CODE 7300SC. Vaal Sanitaryware vitreous china "Pearl Paraplegic" semi-close coupled 90° outlet open rim washdown pan and matching 9 litre cistern complete with lid, fitments, & purpose made C.P. side-flush lever (left or right).Supplied with purpose made thermoset seat and cover plate.

02

02

As per supplier

'VAAL' HIBISCUS BASIN PRODUCT CODE 702303 DESCRIPTION. Vaal Sanitaryware vitreous china 510 x 405mm rounded “Hibiscus” basin with three semi-punched tapholes (i.e. available in zero, one, two or three taphole configurations), integrated overflow, and chainstay hole through the centre semi-punched taphole. To be finished in white as per supplier.

'VAAL Accessories" (code 71511086) 205x160x90mm.Install accessories against brick or tiled wall with super-glue and seal with silicone sealant.

02

02

02

As per supplier

32mm stainless steel grab rail by specialists.As per supplier specifications. Varies

01 - WC

No. Req.Specification

02 - WHB

03 - WHB TRAP & PLUG

04 - VALVE SYSTEM

06 - TOILET ROLL HOLDER

PARAPLEGIC TOILET

05 - GRAB RAILS

Scale 1:100

North Elevation

Scale 1:100

South Elevation

Scale 1:100

West Elevation

Scale 1:100

East Elevation

Scale 1:50

Section A - A

Scale 1:50

Section B - B

Scale 1:20

Typical Elev.Scale 1:20

Sect. C - C

Scale: NTS

Sanitary schedule

New Purpose Made Oregon Pine vertical sliding sash, double glazed window, plugged & screwed into existing brick wall

by Oregon pine specialist.

Old World Concretes Type 6 window sill,size 340 x 85 x 1100mm long bed, bedded

and jointed in Class II mortar and pointed on allexposed faces.

Exisiting Rock walls

Exisiting Rock wall

Gundle® API A.T USB Green 3 layer 250µm damp proof course laid in wall joints, conforming to (SANS 952-1:2011 Type C) laidwith minimum 150mm overlaps and sealed

with Gunplas pressure sensitive tape.

INS

IDE

CO

TTA

GE

AREA SCHEDULE:

Area of existing cottage: 124.87 sq.m

Area of main entr. patio : 19.63 sq.m

Area of existing kitchen patio: 14.23 sq.m

Total Area of existing cottage: 158.73 sq.m

Area of additional ablutions: 18.25 sq.m

Total combined Area of cottage: 176.98

doubleglazing

doubleglazing

doubleglazing

doubleglazing

Stove

Ssteel d/sink

Kitchen

Frdg

1 2

12

Board rm.

Waiting

Area

Reception

Office 1

Office 2

Entrance

patio

Kitchen

patio

Floo

r m

ount

ed c

hairs

2.1m Overhead

Floor mounted chairs

Ladies

Toil.

Gents

Toil.

Whb

WhbWc

Wc

Passage

Kitchen

patio

Lobby

1m Paving apron

1m Paving apron

1m Paving apron

1m Paving apron

1m Paving apron

1m P

avin

g ap

ron

1m P

avin

g ap

ron

porcelain tiles finish

porcelain tiles finish

porcelain tiles finish porcelain tiles finish

porcelain tiles finish

porcelain tiles finishporcelain tiles finish

porcelain tiles finish

porcelain tiles finish

porcelain tiles finish

Plaster & paint

Plaster & paint

Plaster & paint

NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved

Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using

fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations.

Overhangs to be 600mm maximum.

NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved

Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using

fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations.

Overhangs to be 600mm maximum.

NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved

Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using

fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations.

Overhangs to be 600mm maximum.

NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations.Overhangs to be 600mm maximum.

Ridge cap as supplied by "Hulamin"

Sisalation: Sheeting & purlins to have fixedLaminated aluminium, Sisalation®410 Reflective Foil Insulation with reinforced with fiberglass & flame retardant additivesas per Manufacturers specifications.

Lay 135mm Aerolite insulation(Non-combustible andClass 1 fire index rating) on the ceiling ensuring that it fits tightlybetween the tie beams. Aerolite should be cut 50mm more than distance between the tie beams. Cut Aerolite out around trap doors. Fix the cut section to the backof the trap door using a good quality contact adhesive. Wrap Aerolite around cold and hot water pipes ensuring that there is 10mm overlap. Secure the Aerolite using a cable tie at 300mm centres.

K-value: 0.040 W/mK (ASTM C518)

Everite Nutec 6mm thick plain ceiling boards,manufactured in accordance with SANS 9001:2000 carryingSANS 803:2005 mark, fixed smooth face down, to 38mm x 50mm hardwood battens at 600mm centres using32 x 2,5mm serrated ceiling nails at 150mm centres, minimum of 12mm from edge of boards. Applyone coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards.Color as per architect. Finish off with NUTEC 19mm Wood cleat all round, where ceiling meets wall surfaces.

New 25mm Screed of 30MPa strength, on existing concrete slab to fall at 1:100 away from the structure. Screed mixed at 4:1:1 ratio crusher sand: plaster sand: cement and finished smooth with a steel trowel. All concrete workto be inspected and approved by engineers.

85mm reinforced concrete surfacebed,of min. strength 30MPa to Engineers Dets & specs.

85mm reinforced concrete surfacebed,of min. strength 30MPa to Engineers Dets & specs.

Gundle® API A.T USB Green 3 layer 250µm damp proof course laid in wall joints, conforming to (SANS 952-1:2011 Type C)

laid with minimum 150mm overlaps and sealed with Gunplas pressure sensitive tape.

85mm reinforced concrete surfacebed,of min. strength 30MPa to Engineers Dets & specs.

85mm reinforced concrete surfacebed,of min. strength 30MPa to Engineers Dets & specs.

Existing footing Existing footing Existing footing

Existing footing Existing footing Existing footing

New 114x38mm THK SA Pine treated beamsNew 114x38mm THK SA Pine treated beams

Everite Nutec 6mm thick plain ceiling boards,manufactured in accordance with SANS 9001:2000 carryingSANS 803:2005 mark, fixed smooth face down, to 38mm x 50mm hardwood battens at 600mm centres using32 x 2,5mm serrated ceiling nails at 150mm centres, minimum of 12mm from edge of boards. Applyone coat universal primer to all exposed nail heads before applying two coats final paint color to ceiling boards.Color as per architect. Finish off with NUTEC 19mm Wood cleat all round, where ceiling meets wall surfaces.

NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in accordance with the manufacturer`s recommendations.Overhangs to be 600mm maximum.

NEW ROOF NOTE: 'Hulamin' 0,80mm thick Corrugated s-profile or similar SABS approved

Hazy Grey pre-coated finish aluminium roof sheeting, fixed to timber intermediate purlins at 670mm centres

and eaves and ridge purlins at 640mm centres using fastening system approved by manufacturer and fixed in

accordance with the manufacturer`s recommendations.Overhangs to be 600mm maximum.

Lay 135mm Aerolite insulation(Non-combustible andClass 1 fire index rating) on the ceiling ensuring that it fits tightlybetween the tie beams. Aerolite should be cut 50mm more than distance between the tie beams. Cut Aerolite out around trap doors. Fix the cut section to the backof the trap door using a good quality contact adhesive. Wrap Aerolite around cold and hot water pipes ensuring that there is 10mm overlap. Secure the Aerolite using a cable tie at 300mm centres.K-value: 0.040 W/mK (ASTM C518)

d1

d2 d2

d3

d3

d3

d4

d5

d5

w1

w1

w1w1

w3

w3

w2

w2

w2

w2w3

w2w3

w2

w1 w1

w1w1 d1

d2 d2

w2

w2

d1 d2

d3 d3

d3

w2w2

w3

d5

B

B

AA

Scale 1:100

Ground level floor plan