providing right solutions for your ships · 1. standard schedule 1w 2w 3w 4w 5w 6w 7w 8w 9w 10w 11w...
TRANSCRIPT
PrOvIDIng rIghT
SOluTIOnSfor your
ships
Total engineering and design with 3D modeling
Products supply
Installation Onboard
Turnkey Solution
ToTal EnginEEring SoluTionfor rETrofiTTingTechcross provides ship owners who are looking
for retrofitting Ballast Water Management System
with the total engineering solution.
STanDarD
• Onboard survey for pre-engineering • Plan approval drawing for class / ship owner• Installation material supply• BWMS supply• Commissioning / Test
OPTIOn
• 3D installation drawing • Installation onboard• Supervising• BWMP• Turnkey solution
1. Standard
Schedule 1W 2W 3W 4W 5W 6W 7W 8W 9W 10W 11W 12W 13W 14W 15W 16W 17W 18W 19W 20W Total
Kick-off meeting 1
Onboard survey 1
Pre-engineering 2
Contract 2
Approval drawing 1.5
Approval of ship owner / class 3
Installation & manufacturing drawing 3
Fabrication of installation material 3
Customs clearance& shipping 3
Installation & test 2
(unit : week)
- Total 20 weeks after Kick-off meeting- 14 weeks after Contract
2. Procurement of Long-term materialsBWMS 17
Butterfly V/V 8
Production
(12weeks)
Production
(8weeks)
Export shipping
(3weeks)
Test
(2weeks)
Master Schedule
MasterSchedule 1
Process
installation
onboard survey(3D scanning) onboard survey onboard survey
installation test
Kick-off meeting Onboard survey Pre-engineering
Approval drawingApproval of ship owner/class
Contract
Installation & test
Fabrication of installation material
Customs clearance & shipping
Installation & manufacturing drawing
Surveys on possibility of ECS installation
Makes a installation report included quotation according to the onboard survey
Draws detailed PNID, BWMS arrangement and wiring diagram before the installation of ECS
Manufactures material for installation ECS
Receives drawing approval from ship owner and class
Designs the drawing for installation of piping and outfitting
Process 2
ECS supply
3D Modeling Process
Panoramic view around ballast pump
1
3D modeling program view 3
Finish 5
3D view (point data)2
Isometric view4
3DModeling 3
Installation Reference
Shipyard : JapanShip owner : ClosedModel : ECS2000B X 2setsInstallation place : E/R floorDate : January 2012
88K Bulk Carrier
Shipyard : KoreaShip owner : KoreaModel : ECS300A X 1setInstallation place : E/R floorDate : 2006
700TEU Container
Shipyard : ChinaShip owner : KoreaModel : ECS900A X 1setInstallation place : E/R floorDate : August 2009
27K Bulk CarrierShipyard : ChinaShip owner : KoreaModel : ECS1200A X 2setsInstallation place : E/R floorDate : November 2010
73K Bulk Carrier
Reference 4
Product 5
Product
ECU(Electro
Chamber Unit)
ANU•�Dimension (5000T) : W800 X D600
X H1654 (220kg) •�Dimension (10000T) : W1200 X
D600 X H1654 (308kg)•�Neutralizing Agent : Sodium
thiosulfate•�Mixture Ratio : 2(Fresh Water) :
1(Neutralizing Agent)•�Control : Automatic control by
PLC(Programmable Logic Controller)•�Composition : Tank, Control Panel,
Pump, Agitator, Level Sensor, Solenoid Valve, Display Panel
TSU•�Dimension�:������������������������
W470 × D450 × H1347 (100kg) •�Control�:�Automatic control
by PLC(Programmable Logic Controller)•�Composition�:�CLX Sensor, Pump,
Filter, Solenoid valve, PLC•�TRO(Total Residual Oxidant)
concentration measure.
ANU(Auto
Neutralization Unit)
TSU(TRO Sensor
Unit)
150 TYPE•�Dimension : W790 X D564
X H863 (380kg)•�Treatment Capacity :
150㎥/h•�Electrodes : Module Type•�Component : EM(1ea),
PRU(1ea)
300 TYPE•�Dimension : W1140 X D688
X H863 (480kg) •�Treatment Capacity :
300㎥/h•�Electrodes : Module Type•�Component : EM(2ea),
PRU(2ea), EPJ(1ea), ESJ(1ea)
450 TYPE•�Dimension : W1490 X D688
X H863 (580kg)•�Treatment Capacity :
450㎥/h•�Electrodes : Module Type•�Component : EM(3ea),
PRU(3ea), EPJ(1ea), ESJ(1ea)
600 TYPE•�Dimension : W1840 X D688
X H863 (680kg) •�Treatment Capacity :
600㎥/h•�Electrodes : Module Type•�Component : EM(4ea),
PRU(4ea), EPJ(1ea), ESJ(1ea)c
1000 TYPE•�Dimension : W2000 X
D1125 X H865 (1200kg) •�Treatment Capacity :
1000㎥/h•�Electrodes : Module Type•�Component : EM(4ea),
PRU(8ea), EPJ(4ea), ESJ(1ea)
Product 5
Product
PDE• Dimension (A2) : W600 X D630 X
H1500 (175kg) • Dimension (12) : W700 × D530 ×
H1500 (270kg) • Dimension (24) : W700 × D700 ×
H1900 (310kg)• Control : Strong surge-protection,
Remote magnet connect, Automatic / Manual mode selection Rectifier Control Module is control and monitoring of the PRU.
Automatic / Manual System control variables to maintain the preset disinfection performance.• Composition : RTU, CPC, PMU,
HUB, Modbus Gate way
T-strainer • Type : Straight, Angle•�Flange’s bolt-hole arrangement is
straddle.•�Flow direction symbol attached on
the body one side.•Be careful to take out the filter.•�When installed, be careful of the
front and the back.
PDE(Power
Distributor Equipment)
FMU•�Monitors operation of ballast
pump and allows ECS to operate upon ballasting•Fluid Temperature : -10℃~60℃
FMU(Flow Meter
Unit)
CSU•�Measures electrical conductivity
of sea water and sends to CPC
CSU(Conductivity Sensor Unit)
FTS •�Measures temperature of
freshwater
FTS(Freshwater Temperature
Sensor)
CPC•�Window based S/W (software)•�Main control of ECS at cargo
control room
CPC(Control PC
& S/W)
T-strainer
Global A/S Network
AsiaSingapore / Jason ElectronicsJapan / Uzushio Electric Co., LtdChina / Winkong Marine Engineering Co., LtdChina / Dalian Ftz Zhongyi Int’l Industry&Trade Co., Ltd.
Hong Kong / Hongkong United DockyardsTaiwan / Reson Electronics Int’l IncIndia / NorincoUAE / Seven Sea Services
AmericasUSA / Far-East Marine ServiceBrazil / Gehr International
EUROPEGreece / Pera Marine Ltd.Germany / Sam ElectronicsNetherland / Wetering Rotterdam
Poland / Marine Technical Services LtdCroatia / Belam agency and service Ltd.
OceaniaNew Zealand / Titan Marine Engineering
AfricaSouth Africa / Hanam
Network 6
WWW.TeChCrOSS.COM
COPyrIghTⓒ 2013 TeChCrOSS InC.
All rIghTS reServeD.
Tel. +82 51 603 3500
Fax. +82 51 603 3599