DESCRIPTION
Solution Viscosity of polymersTRANSCRIPT
For further details: www.rheotek.com Poulten Selfe & Lee © 2010
PSL Rheotek RPV-1
Version: 072010
● One to four measuring positions● Optional auto sampler● Full compliance with test methods● High precision● Long term reliability
RPV-1 Polymer & Pulp ViscometerIntegrated viscometer system suitable for measuring the solution viscosity of a wide range of polymers dissolved in acids, solvents or water, including PA, PET, PVC, PLA, PBT, PC, PE, PP, Cellulose Acetate, Inks, Pulp, Cellulose, Electrical Papers & other.ASTM D789, D871, D1243, D1601, D2857, D4020, D4603, D1795ISO 175, 307, 1628 Parts 1 to 6DIN Norms 53726, 53727, 53728, 7744 JIS K6721
RPV-1 Systems
The PSL Rheotek RPV-1 provides a reliable and precise system for measuring dilute solutions of polymers, pulp & cellulose.
The RPV-1 automates the manual steps set out in standard methods, minimizing the variability of results.
Standard RPV-1 systems include:
● RPV-1 Polymer ● RPV-1 Pulp ● RPV-1 PP & PE (two positions)
Systems can be configured with 1 to 4 measuring positions.
Flow times are measured automatically using ASTM Ubbelohde viscometer tubes supplied with ISO 17025 certificates of calibration.
Cleaning is carried out in-situ utilizing solvents and a safe vacuum system.
The comprehensive RPV-1 software program records all measurement data as well as calculating a wide range of results.
For further details: www.rheotek.com Poulten Selfe & Lee © 2010
PSL Rheotek RPV-1
Version: 072010
TCB-7 Viscometer Bath● 4 viscometer positions● Cooling coil (see TLC-250 chiller)● HT version for PP/PE applications
RPV-1 System ModulesThe integrated RPV-1 system can be upgraded or expanded as required
TLC-250 Chiller● Suitable for use with the TCB-7 Viscometer Bath● Suitable for use with the SD-1 Dual reaction blocks
RPV-1 Viscometer Control Module ● 2 positions (or up to 2 modules per RPV-1 system● Third solvent option● Nitrogen purge option● Split waste option
RPV-1 Measuring head ● Accomodates ASTM Ubbelohde or Cannon Fenske Routine auto type viscometers
RPV-1 Filling station ● 2 types – manual & auto filling (via XYZ auto sampler)
For further details: www.rheotek.com Poulten Selfe & Lee © 2010
PSL Rheotek RPV-1
Version: 072010
SP Sample Preparation Module● Single or dual syringe pumps● 4 or 5 place precision balance● Integrated with RPV-1 or stand alone use
RPV-1 System OptionsInclude Sample Preparation, Sample dissolution and Smart Sampler
RSS – XYZ auto sampler● Single or dual needles● In-line filtration● Nitrogen purge option
SD-1 Sample dissolution ● Magnetic heating/stirring block
● Dual blocks - cooling option
PC Control system● Internal control cards● RPV-1 software● Up to 4 positions
PIAB vacuum system● Suitable for all RPV-1 systems● Converts compressed air supply into vacuum
RPV-1 – Options & accessories Export results to PC/LIMS interface
Digital Thermometer
RPV-1 Spares Kit Includes essential tools & spare parts
Bath oil Silicone or mineral bath oil
Anti corrosive coating Required for sulfuric acid and DCA applications
Third solvent
Nitrogen purge module Includes nitrogen purge and wand
Split waste Option for solvent waste management
Auto Ubbelohde Auto Ubbelohde viscometer tube
Glass vials 40mL – for use with RSS, SP-1 and SD-1
Black plastic caps For use with glass vials
Magnetic stir bars For use with SD-1
StatsPack
Digital thermometer with PT 100 probe and calibration certificate
Option for third solvent – required for sulfuric acid applications
PSL Rheotek RPV-1
For further details: www.rheotek.com Poulten Selfe & Lee © 2011Version: 072010
The PSL Rheotek range of instruments are manufactured in the United Kingdom by Poulten Selfe and Lee Ltd.
Poulten, Selfe & Lee Ltd. (PSL) was established in 1850. For more than 60 years the company has been specializing in viscosity measurement. PSL's high precision glass capillary viscometers are used worldwide for manual and automated viscosity measurement.
Worldwide, instruments are sold and serviced by a network of PSL Rheotek offices and authorized sales agents.
Poulten, Selfe & Lee LtdRussell HouseBurnham Business ParkBurnham-on-CrouchEssex CM0 8TEUnited Kingdom
USA Sales:Tel.: 502 243 [email protected]
International Sales:Tel.: +44 1621 731 [email protected]
www.rheotek.com
RPV-1 – System ConfigurationsRPV-1 (2) Polymer
RPV-1 (2) Pulp
RPV-1 (2) HT (PP/PE)
RSS
SP-1
SP-1 Dual (Pulp)
SD-1
SD-1 Dual
RPV-1 Automated Polymer Viscometer System. Two measuring positions. RPV-1 Automated Pulp, Cellulose & Electrical Papers Viscometer System. Two measuring positions with nitrogen purge option.
RPV-1 High Temperature (HT) Automated Polymer Viscometer System for PE/PP. Two measuring positions with high temperature bath and control modules.
RSS Smart Sampler – XYZ auto sampler. Two sample loading needles. In-line filtration.
SP-1 Sample Preparation Module with syringe pump, precision balance and voice prompting software. Integrates with RPV-1 System.SP-1 Sample Preparation Module with dual syringe pumps, precision balance and voice prompting software. Integrates with RPV-1 System.SD-1 Sample Dissolution block – suitable for heating & stirring samplesSD-1 Sample Dissolution dual blocks – suitable for heating & stirring samples with dedicated cooling system