psp alpolic /fr cladding system - nz · issue ate: november 1 216 psp alpolic ®/fr cladding system...
TRANSCRIPT
TECHNICAL MANUAL
0800 786 883 | www.alpolicfr.co.nz
PSP ALPOLIC®/fr CLADDING SYSTEM
V: 1
0/17
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
2
1 GENERAL DESCRIPTION 3
2 CODE OF COMPLIANCE WITH NZBC 4
3 SCOPE OF COMPLIANCE 4
4 DESIGN REQUIREMENTS 5
5 CONSTRUCTION REQUIREMENTS 6
6 MAINTENANCE REQUIREMENTS 6
7 WARRANTY 6
8 NOMINATED COMPONENTS 7
CHECK LISTS 8
CONTACT US 38
TABLE OF CONTENTS
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
3
PSP ALPOLIC®/fr is an aluminium composite material (ACM) with a Fire Resistant mineral filled core. It is suitable for use for:• Commercial, High Rise and curtain wall cladding• Corporate Signage• Fascia• Fire-rated Wall linings• Fire-rated Ceiling linings• Feature Walls
ALPOLIC®/fr is coated with Lumiflon FEVE Polymer (CFTE) paint with a 20 year warranty for applications further than 1 km from the ocean and 15 years for closer to water applications.
1. GENERAL DESCRIPTION
Clear Coating
Service Coating
Top CoatingPrimerPretreatment Layer
Aluminium Skin
Pretreatment LayerRust-Preventing Paint
Fire Resistant MineralFilled Core
Rust-Preventing PaintPretreatment Layer
Aluminium Skin
Pretreatment Layer
ALPOLIC®/fr3 coat system for increased 20 year warranty also giving a greater consistency of colour and superior even surface.
High grade of composition the 3105 aluminium with nickle providesincreased stiffness and a high impact resistant surface adds to the overall finish
Further protection against the elements
High grade of composition the 3105 aluminium with nickle providesincreased stiffness and a high impact resistant surface adds to the overall finish
Fire resistant core give the panel its Group 1S Fire rating. The density of the core helps to increase the panels aesthetic and offer in conjunction with the skins a better span ratio for wind loads
Wash coat helps to prevent the oxidation process forming in the cavity caused from condensation and atmospheric conditions present in NZ
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
4
3.1 CLAUSE B1 STRUCTURE
PSP ALPOLIC®/fr Cladding System (PACS), including their fixings, is able to withstand all wind loadings and earthquake zones in all areas of New Zealand in accordance with NZS 3604:2011;
3.2 CLAUSE B2 DURABILITY
When installed in accordance with this technical manual, the PACS meet the requirements of NZBC Clause B2.
When fixed in accordance with this technical manual, the PACS fixings meet the requirements of NZBC Clause B2.
The Lumiflon-based fluorocarbon paint system (ALPOLIC®/fr) is known for its high durability. The PACS meets the requirements of NZBC B2 relating to the resistance of all kinds of weathering attack, provided the integrity of the specified external system.
3.3 CLAUSE E2 EXTERNAL MOISTURE
The PACS, when installed in accordance with technical Literature, will prevent the penetration of water that could cause undue dampness and/or damage to building elements and will therefore comply with clause E2.3.2.
3.4 CLAUSE F2 HAZARDOUS BUILDING MATERIALS
In reference to NZBC Clause F2 regarding Hazardous Building Materials, PSP panels installed in the PACS are non-hazardous, and will not present a health hazard to people.
2. COMPLIANCE WITH THE BUILDING CODE
3. COMPLIANCE OF SCOPE
The PSP ALPOLIC®/fr Cladding System, if designed used and installed and maintained in accordance with this Technical Manual and Details, will meet or contribute to the following provisions of the New Zealand Building Code (NZBC)Clause B1 - Structure: Clause B2 – Durability:Clause C3.4 (a) - Clause C3.5 and C3.7 (b) and (c)Clause F2.3.1, F2.3.3(a) and (b)Clause E23.2, E2.3.5 and E2.3.7 (a, b, c)
ALPOLIC®/fr when used as part of the PSP ALPOLIC®/fr Cladding System is CodeMark certified, confirming that the product has guaranteed acceptance by the regulatory bodies. Any building consent authority must accept a Codemark™ certified product or system, as long as it is used within the conditions and limitations of its certificate of conformity.
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
5
The PSP ALPOLIC®/fr Cladding System is certified for use as a non-load bearing, internal lining or external cladding system on new and existing buildings and the scope of use is defined as:
a) Buildings which fall under the New Zealand Building Code acceptable solutions C/AS1 to 6 and for verification method C/VM2 for buildings with an importance level not greater than 3.
b) Buildings constructed with timber framing, or timber framing infill complying with NZBC. This does not limit the panel being fixed to steel framing, concrete or concrete masonry.c) Buildings subject to maximum wind pressures for weather- tightness design of 2.5kPa Ultimate Limit State (ULS).
d) Buildings where the cavity is drained and ventilated at least at every second floor level-or 10m height, whichever is the lesser.
Compliance with B2.3.1. (b) for a 15 year period where the building is within a 1 km distance from the sea, otherwise for a 20 year period.
Compliance with C3.4 (a) is applicable where a Group 1-S rating is permitted.
Compliance with C3.5 and C3.7 (b) and (c) includes buildings greater than 10m in height and less than 1m in distance to the boundary provided the building is designed by a suitably qualified engineer in accordance with AS/NZS 1170.
The compliance requirements of the wall the PSP ALPOLIC®/fr Cladding System is attached to is outside the scope of this technical manual, including fire resistance, acoustics and energy efficiency.
Weather tightness details which are developed by the designer outside the scope of this technical manual are the responsibility of the designer for compliance with the NZBC.Significant acceleration of corrosion can occur due to industrial contamination and corrosive atmospheres and contamination from agricultural chemicals and fertilisers. Specific Engineering Design is required under these micro climatic conditions.
4. DESIGN REQUIREMENTS
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
6
6 MAINTENANCE REQUIREMENTS
Regular maintenance is essential to maximise the serviceable life of the PSP ALPOLIC®/fr Cladding system.
An inspection of PSP ALPOLIC®/fr Cladding system installations should be undertaken at least annually to determine the condition of the whole building. Items to be checked include, but are not limited to:
a) Dirt - any accumulation of dirt should be washed from the surface of the panels.b) Scratches and Dents - these need to be identified and repaired.c) Joint Sealant - identify any failures and repair
7. WARRANTY
The manufacturer of the ALPOLIC®/fr ACM panels provides a minimum of 15 years warranty (from date of completion) when the panel forms part of the PSP ALPOLIC®/fr cladding system closer than 1 km from the ocean.The manufacturer of the ALPOLIC®/fr ACM panels provides a minimum of 20 years warranty (from date of completion) when the panel forms part of the PSP ALPOLIC®/fr cladding system further than 1 km from the ocean.PSP Limited warrant the PSP ALPOLIC®/fr Cladding System for not less than 15 years provided it is installed in accordance with the most current PSP technical literature.
5 CONSTRUCTION REQUIREMENTS
a) The PSP ALPOLIC®/fr Cladding System must be installed by an installer approved by PSP Limited.
b) The wall structure to which the Cladding System is attached to must be able to be support the intended building work as designed by suitability qualified engineers and must not be subjected to wind loads exceeding ULS 2.5kPA. Supporting substrates may be timber or steel framing, concrete or concrete masonry.
c) Vertical compartmentalisation with airtightness exceeding 0.1 MNs/m3 is required of the cladding cavity within 500mm of every corner, at 2m centres after that, to a maximum of 5m centres where cladding panels are located further than 2.5m from any edge of the cladding, or areas where airflows are interrupted.
d) A building with wind exposure of less than 1.1 kPa ULS must have a building wrap complying with NZBC Clause E2/AS1 Table 23, or a rigid air barrier (RAB)
e) A building with any exposure to wind above 1.1 kPa ULS must have building wrap or a rigid air barrier that has an airflow resistance of greater than 0.1 MNs/m3.
f) A building with exposure on any part of its face above a 1.55 kPa ULS must use a RAB as the backing for a cavity.
g) The installation must be carried out in accordance with the PSP ALPOLIC®/fr technical literature.
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
7
8. NOMINATED SYSTEM REQUIREMENTS
a) ALPOLIC®/fr ACM Panels
Sizes available: 2489mm x 1575mm, 3099mm x 1270mm, 3099mm x 1575mm & 4000mm x 1575mm
Colours Available: White M9010, Black MJ062, Charcoal M7991, Silver Metallic M9170, Dark Grey Metallic MB106, Champagne Metallic M9177, Medium Bronze Metallic M9221, Galaxy Metallic BF7542, Sparkling White MD046, Sparkling Black MD044, Sparkling Grey MD045, Sparkling Dark Grey MD049 & Cloud White Matte CWM
b) Stainless Steel fixings in accordance E2/AS1 Table 20 and current NZBC legislationc) Flashings – Marshall innovations trade seal self-adhesive collard) Metal flashings complying with E2/AS1 Table 7 and current NZBC legislatione) Sealants Sikaflex AT Façade Holdfast Fix All MS Polymerf) Aluminium Angle Fixing Bracketsg) PEF backing rodsh) Plastic Packers/shims
Where products other than the above are substituted it is the responsibility of the installer to ensure that the product is fit for purpose. If nominated components are substituted without the knowledge of PSP Limited, any warranties may be void.
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
8
PRE-CLADDING CHECKLISTFor builders, trained installers & building inspectors
Consent No:
Commence Date:
Client Name: phone:
Builder: phone:
Architect: phone:
Floor slab layout:- Ensure distance from outside of framing to outside of concrete footing is exactly 50 on all sides of building.- If slightly under it is okay on single storey. This allows 50mm for the PSP ALPOLIC®/fr panels.- Ensure ground level is 250mm below floor level, minimum 300mm out around base to allow for installation work.
Rebate:- Install approved DPC as per manufacturers’ specifications.- Smooth and level
Framing: - All straight and level - Studs straightened for wall lining before PSP ALPOLIC®/fr panels are installed
Wall Wrap/ Rigid Air Barrier:- Exterior timber framed walls must be wrapped with building wrap that complies compliance document E2/AS1 table 23.- RAB/Wall wrap must be fixed to the exterior wall framing prior to installation of PSP ALPOLIC®/fr panels.- Ensure wall wrap/RAB is continuous around corners and installed horizontally.- Ensure that all penetrations such as waste water pipes and the like have been flashed to the building wrap using “approved flexible flashing tape”.
Joinery:- The builder is also responsible for the application of approved flexible flashing tape around openings prior to the installation of any joinery.
Plumbing:- All plumbing including gas lines need to be pressure tested prior to installation of internal linings.
Owner/Builder must have the framing and other components of the building correctly installed to enable the installation of the cladding
system.
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
9
Variables / Concerns / Comments:
Builder / Owner:
Signature:
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
10
PRE-SEALANT CHECKLISTFor builders, trained installers & building inspectors
Consent No:
Commence Date:
Client Name: phone:
Builder: phone:
Architect: phone:
Panels must be flat, true & straight with minimum 6 screws per sheet
All external and internal corners are vertical and square, and fastened with the screws tightly
Ensure that the drainage holes of window head, cladding base are in place and installed properly
Ensure window head flashing tape is fixed in place, level, straight, tightly and properly
Sill and base flashings are installed as required in this specification
All pipe work/penetrations through cladding are installed as required in this specification
PSP recommends an inspection by Building Inspector prior to sealant
Variables / Concerns / Comments:
Allegiance Installer:
Signature:
Approved by:
Signature:
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
11
FINAL CHECKLISTFor builders, trained installers & building inspectors
Consent No:
Commence Date:
Client Name: phone:
Builder: phone:
Architect: phone:
Specified depth and width of sealant have been applied, finished to manufacturer’s specification
All the drainage holes are working and not blocked
Specified review of coating system has been applied, any damage of coatings is repaired and finished to manufacturer’s standard
All the penetrations including plumbing pipe work and the like are filled with foam tape under fittings
Variables / Concerns / Comments:
Builder/Owner:
Signature:
Approved by:
Signature:
Issue date: August 15, 2016
STANDARD HORIZONTAL JOINT DETAIL
12
BUILDING WRAP/RAB BOARD/AIRBARRIER BY OTHERS
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
PSP APPROVED SEALANTON PEF ROD
PACKERS BY PSPAPPROVED INSTALLER
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
TIMBER FRAMING BYOTHERS
UNDER LEG
OVER LEG
50-55mm CAVITY APPROX.
14mm
01
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
STANDARD HORIZONTALJOINT DETAIL
1:2 @ A4
Issue date: August 15, 2016
STANDARD VERTICAL JOINT DETAIL
13
INTERNAL LINING BYOTHERS
TIMBER FRAMING BYOTHERS
PACKERS BY PSPAPPROVED INSTALLER
PSP APPROVED SEALANTON PEF ROD
OV
ER
LE
G
UN
DE
R L
EG
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
BUILDING WRAP/RAB BOARD/AIRBARRIER BY OTHERS
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
50-55mm CAVITYAPPROX.
14mm
02
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
STANDARD VERTICALJOINT DETAIL
1:2 @ A4
Issue date: August 15, 2016
STANDARD OPEN JOINT DETAIL
14
UNDER LEG
OVER LEG
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
TIMBER FRAMING BYOTHERS
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
0.9mm ALUMINIUM BACKFOLDSUPPORT BY PSP APPROVEDINSTALLER
FLASHINGS BY OTHERS
4mm INTERMITTENTSPACES
VENTILATION BY PSPAPPROVED INSTALLER
15mm OPENDRAINAGE JOINT
INTERNAL LINING BYOTHERS
50-55mm CAVITY APPROX.
03
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
STANDARD OPEN JOINT DETAIL
1:2 @ A4
Issue date: August 15, 2016
COMMERCIAL WINDOW HEAD DETAIL
15
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
BUILDING WRAP/RABBOARD/AIR BARRIERBY OTHERS
TIMBER FRAMINGBY OTHERS
INTERNAL LININGBY OTHERS
FIXING ANGLE BY PSPAPPROVED INSTALLER
DRAINAGE/VENTILATIONSLOTS BY PSP APPROVEDINSTALLER
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
FLASHINGS BY OTHERS
AIR SEAL
14mm
20mm min
50-55mm CAVITY APPROX
04
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
COMMERCIAL WINDOW HEAD DETAIL
1:2 @ A4
Issue date: August 15, 2016
RESIDENTIAL WINDOW HEAD DETAIL
16
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
BUILDING WRAP/RABBOARD/AIR BARRIER BYOTHERS
TIMBER FRAMING BYOTHERS
INTERNAL LINING BYOTHERS
FIXING ANGLE BY PSPAPPROVED INSTALLER
DRAINAGE/VENTILATIONSLOTS BY PSP APPROVEDINSTALLER
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
FLASHINGS BY OTHERSAIR SEAL
18mm min14mm
50-55mm CAVITY APPROX
05
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
RESIDENTIAL WINDOW HEAD DETAIL
1:2 @ A4
Issue date: August 15, 2016
COMMERCIAL WINDOW SILL DETAIL
17
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
PACKERS BY PSPAPPROVED INSTALLER
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
FLASHINGS BY OTHERS
SEALANT ON BONDBREAKER TAPE
10° SLOPE MIN
TIMBER FRAMINGBY OTHERS
LINING BYOTHERS
AIR SEAL
50-55mm CAVITY APPROX
06
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
COMMERCIAL WINDOW SILL DETAIL
1:2 @ A4
Issue date: August 15, 2016
RESIDENTIAL WINDOW SILL DETAIL
18
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
PACKERS BY PSPAPPROVED INSTALLER
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
SILL FLASHINGS BYOTHERS
SEALANT ON BONDBREAKER TAPE
10° SLOPE MIN
TIMBER FRAMINGBY OTHERS
LINING BYOTHERS
AIR SEAL
50-55mm CAVITY APPROX
07
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
RESIDENTIAL WINDOW SILL DETAIL
1:2 @ A4
Issue date: August 15, 2016
FASCIA DETAIL 1 - ACM PANEL SOFFIT
19
DRAINAGE/VENTILATION SLOTSBY PSP APPROVED INSTALLER
ALPOLIC FR ACM FIXING ANGLEBY PSP APPROVED INSTALLER
50m
m
SIZE TO SUIT
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
BUILDING WRAP/RABBOARD/AIR BARRIER BYOTHERS
PACKERS BY PSPAPPROVED INSTALLER
TIMBER FRAMING BYOTHERS
FLASHINGS, FLASHINGTAPE OR WATERPROOFMEMBRANE BY OTHERSOVER PARAPET
5° SLOPE MIN
25mm
DRAINAGE/VENTILATION SLOTSBY PSP APPROVED INSTALLER
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLERPSP APPROVED SEALANT
ON PEF ROD OR OPENJOINT
14mm
50-55mm CAVITY APPROX
TO SUIT
35mm minCLEARANCE
08
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
FASCIA DETAIL 1 - ACM PANEL SOFFIT
Issue date: August 15, 2016
FASCIA DETAIL 2 - ACM PANEL SOFFIT 1
20
DRAINAGE/VENTILATION SLOTSBY PSP APPROVED INSTALLER
ALPOLIC FR ACM FIXING ANGLEBY PSP APPROVED INSTALLER
50m
m
SIZE TO SUIT
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
BUILDING WRAP/RABBOARD/AIR BARRIER BYOTHERS
PACKERS BY PSPAPPROVED INSTALLER
TIMBER FRAMING BYOTHERS
FLASHINGS, FLASHINGTAPE OR WATERPROOFMEMBRANE BY OTHERSOVER PARAPET
5° SLOPE MIN
25mm
DRAINAGE/VENTILATION SLOTSBY PSP APPROVED INSTALLER
PSP APPROVED SEALANT ON PEFROD OR LEFT OPEN
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
CONTINUOUS ALUMINUM ORALPOLIC FR ACM ANGLE BYPSP APPROVED INSTALLER
12mm
50-55mm CAVITY APPROX
TO SUIT
35mm minCLEARANCE
TO SUIT
09
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
FASCIA DETAIL 2 - ACM TO OTHERSOFFIT 1
Issue date: August 15, 2016
FASCIA DETAIL 3 - ACM PANEL SOFFIT 2
21
DRAINAGE/VENTILATION SLOTSBY PSP APPROVED INSTALLER
ALPOLIC FR ACM FIXING ANGLEBY PSP APPROVED INSTALLER
50m
m
SIZE TO SUIT
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
BUILDING WRAP/RABBOARD/AIR BARRIER BYOTHERS
PACKERS BY PSPAPPROVED INSTALLER
TIMBER FRAMING BYOTHERS
FLASHINGS, FLASHINGTAPE OR WATERPROOFMEMBRANE BY OTHERSOVER PARAPET
5° SLOPE MIN
25mm
DRAINAGE/VENTILATION SLOTSBY PSP APPROVED INSTALLER
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLEROPEN JOINT- APPROX 10 mm
SOFFIT PANELS BYOTHERS
50-55mm CAVITY APPROX
TO SUIT
35mm minCLEARANCE
10
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
FASCIA DETAIL 3- ACM TO OTHERSOFFIT 2
Issue date: August 15, 2016
PARAPET DETAIL
22
50m
m
SIZE TO SUIT
FLASHINGS,FLASHING TAPEOR WATERPROOFMEMBRANE BYOTHER OVERPARAPET
5° SLOPE MIN
25mm
STAINLESS STEELFIXING BY PSPAPPROVED INSTALLER
BUILDING WRAP/RAB BOARD/ AIRBARRIER BY OTHERS
PACKERS BYPSP APPROVEDINSTALLER
ALPOLIC FR ACMPANEL BY PSPAPPROVED INSTALLER
ALPOLIC FR ACMFIXING ANGLE BY PSPAPPROVED INSTALLER
DRAINAGE/VENTILATIONSLOTS BY PSPAPPROVEDINSTALLER
50-55mm CAVITYAPPROX
TO SUIT
35mm minCLEARANCE
11
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
PARAPET DETAIL
1:2 @ A4
Issue date: August 15, 2016
RESIDENTIAL JAMB DETAIL
23
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
LINING BY OTHERS
TIMBER FRAMING BYOTHERS
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
FIXING ANGLE BY PSPAPPROVED INSTALLER
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
PSP APPROVED SEALANTON PEF ROD
50-55mm CAVITY APPROX
AIR SEAL
14mm
20mm min15mm min
12
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
RESIDENTIAL JAMB DETAIL
1:2 @ A4
Issue date: August 15, 2016
COMMERCIAL JAMB DETAIL
24
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
LINING BY OTHERS
TIMBER FRAMING BYOTHERS
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
FIXING ANGLE BY PSPAPPROVED INSTALLER
STAINLESS STEELFIXING BY PSPAPPROVED INSTALLER
PSP APPROVEDSEALANT ON PEF ROD
50-55mm CAVITY APPROX
AIR SEAL
14mm
20mm min15mm min
13
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
COMMERCIAL JAMB DETAIL
1:2 @ A4
Issue date: August 15, 2016
ALTERNATIVE RESIDENTIAL JAMB DETAIL
25
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
LINING BY OTHERS
TIMBER FRAMING BYOTHERS
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
PSP APPROVED SEALANT ONTHERMAL BREAK
50-55mm CAVITY APPROX
AIR SEAL
PACKERS BY PSPAPPROVED INSTALLER
14
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
ALTERNATIVE RESIDENTIAL JAMBDETAIL
1:2 @ A4
Issue date: August 15, 2016
ALTERNATIVE COMMERCIAL JAMB DETAIL
26
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
LINING BY OTHERS
TIMBER FRAMING BYOTHERS
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
STAINLESS STEELFIXING BY PSPAPPROVED INSTALLER
PSP APPROVED SEALANTON THERMAL BREAK
50-55mm CAVITY APPROX
AIR SEAL
PACKERS BY PSPAPPROVED INSTALLER
15
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
ALTERNATIVE COMMERCIAL JAMBDETAIL
1:2 @ A4
Issue date: August 15, 2016
BASE CLEARANCE DETAIL - 1
27
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
FIXING ANGLE BY PSPAPPROVED INSTALLER
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
DRAINAGE/VENTILATIONSLOTS BY PSP APPROVEDINSTALLER
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
50-55mm CAVITY APPROX
100mm min
50mm min
16
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
BASE CLEARANCE DETAIL-1
1:2 @ A4
Issue date: August 15, 2016
BASE CLEARANCE DETAIL - 2
28
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
DRAINAGE/VENTILATIONSLOTS BY PSP APPROVEDINSTALLER
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
PACKERS BY PSP APPROVEDINSTALLER
STIFFENER /GLUE BLOCK
50-55mm CAVITY APPROX
100mm min
50mm min
17
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
BASE CLEARANCE DETAIL-2
1:2 @ A4
Issue date: August 15, 2016
BASE CLEARANCE DETAIL - 3
29
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
PACKERS BY PSP APPROVEDINSTALLER
50-55mm CAVITY APPROX 100mm min
50mm min
18
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
BASE CLEARANCE DETAIL-3
1:2 @ A4
Issue date: August 15, 2016
ACM PRECAST JUNCTION DETAIL -1
30
STAINLESS STEELFIXING BY PSPAPPROVED INSTALLER
BUILDING WRAP/RAB BOARD/ AIRBARRIER BYOTHERS
ALPOLIC FR ACMPANEL BY PSPAPPROVED INSTALLER
PACKERS BYPSP APPROVEDINSTALLER
PSP APPROVED SEALANTON PEF ROD
FIXING ANGLE OR PACKINGOFF FRAMEWORK BY PSPAPPROVED INSTALLER
12mm
50-55mm CAVITYAPPROX
19
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
ACM PRECAST JUNCTION DETAIL-1
1:2 @ A4
Issue date: August 15, 2016
ACM PRECAST JUNCTION DETAIL -2
31
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
BUILDING WRAP/RABBOARD/ AIRBARRIER BY OTHERS
ALPOLIC FR ACM PANELBY PSP APPROVEDINSTALLER
PACKERS BY PSPAPPROVED INSTALLER
CONTINUOUS FLASHINGSCHASED INTO PRECAST BYOTHERS
PSP APPROVED SEALANTON PEF ROD
50-55mm CAVITY APPROX
12mm
20
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
ACM PRECAST JUNCTION DETAIL-2
1:2 @ A4
Issue date: August 15, 2016
EXTERNAL CORNER DETAIL
32
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
BUILDING WRAP/RABBOARD/AIR BARRIER BYOTHERS
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
PACKERS BY PSPAPPROVED INSTALLER
TIMBER FRAMING BYOTHERS
50-55mm CAVITY APPROX
21
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
EXTERNAL CORNER DETAIL
1:2 @ A4
Issue date: August 15, 2016
INTERNAL CORNER DETAIL
33
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
PACKERS BY PSPAPPROVED INSTALLER
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
PSP APPROVED SEALANTON PEF ROD
TIMBER FRAMINGBY OTHERS
LINING BYOTHERS
50-55mm CAVITY APPROX
22
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
INTERNAL CORNER DETAIL
1:2 @ A4
Issue date: August 15, 2016
SOFFIT/WALL JUNCTION DETAIL - 1
34
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
PACKERS BY PSPAPPROVED INSTALLER
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
PSP APPROVED SEALANT ONPEF ROD OR LEFT OPEN
TIMBER FRAMINGBY OTHERS
LINING BYOTHERS
SOFFIT BY OTHERS
50-55mm CAVITY APPROX
14mm
23
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
SOFFIT/WALL JUNCTION DETAIL-1
1:2 @ A4
Issue date: August 15, 2016
SOFFIT/WALL JUNCTION DETAIL - 2
35
STAINLESS STEEL FIXING BYPSP APPROVED INSTALLER
BUILDING WRAP/RAB BOARD/AIR BARRIER BY OTHERS
ALPOLIC FR ACM PANEL BYPSP APPROVED INSTALLER
TIMBER FRAMINGBY OTHERS
LINING BYOTHERS
SOFFIT BY OTHERS
PACKERS BY PSPAPPROVED INSTALLER
50-55mm CAVITY APPROX
24
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
SOFFIT/WALL JUNCTION DETAIL-2
1:2 @ A4
Issue date: August 15, 2016
TYPICAL EYEBROW DETAIL
36
DRAINAGE/VENTILATIONSLOTS BY PSP APPROVEDINSTALLER
ALPOLIC FR ACMPANEL BY PSPAPPROVED INSTALLER
BUILDING WRAP/RABBOARD/AIR BARRIERBY OTHERS
STAINLESS STEELFIXING BY PSPAPPROVED INSTALLER
PSP APPROVEDSEALANT ON PEF ROD
FLASHINGS BYOTHERS
DRAINAGE/VENTILATIONSLOTS BY PSP APPROVEDINSTALLER
50-55mm CAVITYAPPROX.
GUSSETS IN CORNERS BY PSPAPPROVED INSTALLERDEPENDING ON SPECIFICATIONREQUIREMENTS
14mm
25
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
TYPICAL EYEBROW DETAIL
1:5 @ A4
Issue date: August 15, 2016
STANDARD
37
PIP
E
±5 m
m
BACKING PLATE (IF REQ'D)BY PSP APPROVEDINSTALLER
TIGHT FIT ALPOLIC FR ACMBACKING PLATE BY PSPAPPROVED INSTALLER
CONTINUOUS SEALANT BYPSP APPROVED INSTALLER
PIPE
ALPOLIC FR ACM PANEL BY PSPAPPROVED INSTALLER
PIPE
ALPOLIC FR ACM PANELBY PSP APPROVEDINSTALLER
ELEVATION
OUTSIDE INSIDE
CONTINUOUS SEALANTSURROUNDING JOINTPENETRATION
26
Copyright - This drawing remains the property of PSP ltd.
SHEET NO.DRAWING TITLE:SCALE:
PSP
c
DRAWN BY:
CHECKED BY:
DATE:
Web Site www.psp.co.nz
JUNE, 2016
STANDARD PENETRATION DETAIL
1:2 @ A4
Issue date: November 1, 2016
PSP ALPOLIC®/fr CLADDING SYSTEM
38
8. CONTACT US
ALBANY (HEAD OFFICE)320 Rosedale Road Ph: 09 415 2800Albany 0632 Fax: 09 415 2809PO Box 101 851 Email: [email protected]
AUCKLAND60a Cryers Road Ph: 09 274 1800 East Tamaki 2013 Fax: 09 271 2833Auckland Email: [email protected]
HAMILTON13 Tawn Place Ph: 07 850 6280Pukete 3200 Fax: 07 850 6284PO Box 770 Email: [email protected]
WELLINGTON61 Seaview Road Ph: 04 568 7180Seaview 5012 Fax: 04 568 7183PO Box 38237 Email: [email protected]
CHRISTCHURCH72 Hammersmith Drive Ph: 03 341 0248Sockburn 8042 Fax: 03 341 0257PO Box 2841 Email: [email protected]