pulse checker model:pc2201

12
Ins. No. E 935 1-E 1 PULSE CHECKER MODEL:PC2201 This manual has been prepared to provide you with the information pertinent to the PULSE CHECKER. This product is fabricated and shipped from our factory under stringent quality control. With the proper application of the information and knowledge contained in this manual, you will be able to ex- pect the best possible results over a long service life of this instrument. Keep this manual at hand for your quick reference.

Upload: others

Post on 24-Dec-2021

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PULSE CHECKER MODEL:PC2201

Ins. No. E−935−1-E

1

PULSE CHECKERMODEL:PC2201

This manual has been prepared to provide you with the information pertinent to the PULSE CHECKER. This product is fabricated and shipped from our factory under stringent quality control. With the proper application of the information and knowledge contained in this manual, you will be able to ex-pect the best possible results over a long service life of this instrument. Keep this manual at hand for your quick reference.

Page 2: PULSE CHECKER MODEL:PC2201

E-935-1-E

CONTENTS

1. GENERAL ………………………………………………………………… 3

2. PART NAMES ……………………………………………………………… 3

3. SYSTEM CONFIGURATION ……………………………………………… 4

4. DESCRIPTION OF FUNCTIONS ………………………………………… 5

5. GENERAL SPECIFICATIONS ……………………………………………11

6. OUTLINE DIMENSIONS ……………………………………………………11

7. STANDARD ACCESSORIES ………………………………………………11

This manual uses the precaution words "NOTE", "CAUTION", and "WARNING" as explained below:

NOTE:Notes are separated from the general text to bring the user's attention to important information.

CAUTION:Caution statements inform the user of hazards or unsafe practices which could result in minor personal injury or product/property damage.

WARNING:Warning statements inform the user of hazards or unsafe practices which could result in severe personal injury or death.

Page 3: PULSE CHECKER MODEL:PC2201

E-935-1-E

3

1. GENERALThis pulse checker is designed for inspecting, adjusting and maintaining a wide variety of equipment associated with pulse signals. It features two groups of functions - the input functions which include the accumulation, frequency measurement, period measurement and gated accumulation of input pulses and the output functions which include the digital selection of the reference frequency, frequency reduction and output frequency programming by selecting % frequency reduction, the control of the number of output pulses, as well as the selection of pulse width and generator type.Despite these elaborate capabilities, this portable pulse checker is easy to use.To derive maximum benefit from the instrument, we recommend that you familiarize yourself with the instructions contained in this manual.

2. PART NAMES

No. NAME DESCRIPTION1 DC IN Connector to the ac adaptor furnished2 POWER Power switch3 FUNCTION Input counter function select rotary switch4 INPUT LEVEL Input pulse trigger level select rotary switch5 INPUT COUNTER 8-digit LCD Input counter6 RESET Input counter reset pushbutton switch7 INPUT Input terminals to banana plugs of the furnished cords8 FREQUENCY 4-digit decade switch for establishing the reference frequency9 PRESET 8-digit decade switch for establishing the output pulse number10 START Output counter "Start" pushbutton switch, LED (green) lighted11 RESET Output counter "Reset" pushbutton switch, LED (yellow) lighted12 STOP Output counter "Stop" pushbutton switch, LED (red) lighted13 OUTPUT COUNTER 8-digit LCD output counter14 RATING Reference frequency reduction rotary switch15 %SETTER Reference frequency % setting rotary switch16 WIDTH Output pulse width setting rotary switch17 OUTPUT Output generator type select rotary switch18 OUTPUT Output terminals to banana plugs of the furnished cords19 Battery compartment cover20 Carrying strap attachment fitting21 Rubber foot

SUP SIG SIG GATEOV OV

OUTPUT INPUT

INPUT LEVEL INPUT COUNTER

OUTPUT COUNTER

FUNCTION

OUTPUT WIDTH %SETTER RATING STOP RESET START

PULSE CHECKER PC 2201

PRESET

FREQUENCY RESET

POWER

DC IN

100101

1K10K

3075100

250

150

0.251.1

(ma)

PG30SO. CVOLTPA11

P. APG30PG20

OPTO

PERIODRATIO

10515

COUNT

FREO

36

15

D.C

1.5

(V)

18 5 7 8 6 9 20

21

1

2

19

1011121314151617

3

4

Page 4: PULSE CHECKER MODEL:PC2201

E-935-1-E

TRIGGER LEVEL SET GATE INPUT INTEGRATOR

WAVE SHAPING

8-DIGIT LCDDISPLAY

4-DIGIT DECADESWITCH

CRYSTALOSC.

% FREQUENCYREDUCTION×1/6 SCALER×1/100

"END"BUZZER BATCH CONTROL CIRCUIT FREQ.REDUCTION

8-DIGIT DECADESWITCH

8-DIGIT LCDDISPLAY

COUNT COLLATE OUTPUT COUNTER

OUTPUT SIGNAL SELECT CKT. PULSE WIDTH SHAPING

STABILIZED VOLT

BATTERIES CHARGE/DISCHARGE DC/DC CKT.

AC ADAPTOR100VAC50/60Hz

UM-3 Ni-Cd BATTERY×6

COUNTING SUSPENDED END

3. SYSTEM CONFIGURATION

Page 5: PULSE CHECKER MODEL:PC2201

E-935-1-E

5

4. DESCRIPTION OF FUNCTIONS1. Power Functions (1)“DC IN”connector…… Connects to the furnished AC adaptor. (2)“POWER”switch …… Furnishes power to the circuitry when turned on. The Input and output counter LEDs light up at the same time.

This checker operates on a two-way power supply system. When this switch is turned on with no external power furnished through the ac adaptor, the instrument operates on internal batteries. The batteries are of rechargeable type and good for about 5 hours of operation if fully charged in 24 hours. (Connected to an external power source through the ac adaptor, the batteries will be fully charged in 24 hours with power switch off.)When the battery terminal voltage drops below serviceable level, the input and output counter LCDs begin to flicker.)Although the checker is serviceable for 10 to 15 minutes with the LCDs flickering, it is recommended that the batteries be recharged immediately or an ac power be furnished through the ac adaptor to eliminate possible erratic operation.The batteries should be replaced every year, although their life may vary depending on the given operating conditions.

2. Input Functions (1)“INPUT”terminals  “SIG”  …… Input terminals to accept pulse signals with selectable trigger level.  “GATE”…… Input terminals to accept gate pulses.          Trigger level: 2.5V  Hysteresis: 0.1V          Pulse width response: 1μs min.          Frequency response: 5Hz max.  “0V”:  …… Common 0V line (2)“INPUT LEVEL”Select Switch 

This checker has no internal power supply for pulse generators. It therefore cannot drive directly the pulse generators described in the“Receive Signal”columns above.So, couple with other receiving instrument which has an internal power supply and pick up its signal only. In case of PA04, 05, 45 or PG60A (E), it may be“6”depending on the position of picking up the signal.

Select Trigger Level Hysteresis Response Freq. Receive Signal15 1.5V 0.1V 300kHz Voltage pulse signal at IC levelOC 11.3kΩ 20kΩ 10kHz Pulse signal of no voltage (W/pull up resistor)3 3.0V 0.1V 10kHz PG306 6.0V 0.2V 10kHz PG30S18 18.0V 0.6V 10kHz PA04, 05, 45 and PG60A (E)

[18]IS CHOSEN

[6]IS CHOSEN

PC2201

PC2201

SIG

SIG

INPUT

INPUT

0V

0V

PULSEGENERATOR

PULSEGENERATOR

510Ω

510Ω

24V

24V

SIG

SIG

0V

0V

RECEIVING INSTRUMENT

CAUTION:

CAUTION:

Page 6: PULSE CHECKER MODEL:PC2201

E-935-1-E

(3)“FUNCTION”Select Switch Selects“INPUT COUNTER”functions. “COUNT” …… Accumulated total counter          Counts the number of incoming pulses at“SIG”terminals. “FREQ 1S”…… Frequency counter with one second gate          Counts the number of incoming pulses at“SIG”terminals for a period of one second → Displays it for one second → Reset to“0”. The cycle above is repeated.          Unit of measure displayed on the counter …… “Hz”  “FREQ 10S” … Frequency counter with 10-second gate          Counts the number of incoming pulses at“SIG”terminals for 10 seconds → 2 sec. hold displayed →“0”reset.          This cycle is repeated.          Unit of measure displayed on the counter …… “Hz” “PERIOD” …… Period counter with 1MHz pulses          Counts the period of incoming pulses at“SIG”terminals against the 1MHz internal pulses and displays it, latched.          Unit of measure displayed on the counter …… μs “RATIO”  …… Gated accumulated total counter          Counts the number of incoming pulses at“SIG”terminals at the intervals of pulses incoming through“GATE”terminals and displays it, latched.

(4)“RESET”Pushbutton Switch   Upon depression, the“INPUT COUNTER”is reset to“0”. (5)“INPUT COUNTER”   An 8-digit LCD accumulated total counter. Its functions are selectable with“FUNCTION”select switch.

3. Output Functions (1)“FREQUENCY”Preset Switch

  Establishes the reference frequency of output pulses with 4-digit decade switch.  Preset coverage: 1 to 9999Hz (in 1Hz steps)

(2)“RATING”Select Switch  Selects the decimal point of the“FREQUENCY”reference frequency.  “1”  …… The decimal point of 4-digit decade switch is □□□□. Hz  “10” …… The decimal point of 4-digit decade switch is □□□.□ Hz  “100”…… The decimal point of 4-digit decade switch is □□.□□ Hz  “1K” …… The decimal point of 4-digit decade switch is □.□□□ Hz  “10K”…… The decimal point of 4-digit decade switch is 0.□□□□ Hz

(3)“% SETTER”Select Switch  Selects % frequency reduction of the reference frequency.  “100”…… Provides the reference frequency output with the decimal point chosen as above.  “75” …… Provides the reference frequency output ×0.75 with the decimal point chosen as above.  “50” …… Provides the reference frequency output ×0.5 with the decimal point chosen as above.  “25” …… Provides the reference frequency output ×0.25 with the decimal point chosen as above.  “0”  …… No output is provided.

(4)“PRESET”Switch  Presets the number of output pulses with 8-digit decade switch.  Upon“START”button depression, the checker produces the number of pulses preset before it comes to stop pulse generation automatically.  Preset coverage: 1 to 99999999 P (in 1P steps)

Page 7: PULSE CHECKER MODEL:PC2201

E-935-1-E

(5)“START”Pushbutton Switch   The checker produces a pulse train of the frequency selected by the switches“FREQUENCY”, “RATING”and“% SETTER”for the number of pulses selected by the“PRESET”switch upon button depression.   The“OUTPUT COUNTER”counts the output pulses being produced and the green LED on this button lights up, indicating“COUNTING”.(6)“STOP”Pushbutton Switch   At touch of this button, pulse output may be interrupted before the number of pulses established by the“PRESET”switch is reached.   While pulse generation is interrupted, the“STOP”red LED on this button lights.(7)“RESET”Pushbutton Switch   Resets the“OUTPUT COUNTER”to zero upon actuation of the button. It is inhibited while the green“COUNTING”LED is illuminated, however.   When the accumulated total count on the“OUTPUT COUNTER”has reached the“PRESET”count, the checker shuts off pulse output generation automatically; a buzzer sounds for about 1.5 seconds and the yellow“END”LED on the button comes on. It remains illuminated until this button is pressed.

  [Operations Sequence Time Chart]

 (8)“OUTPUT COUNTER”   Counts the number of output pulses with an 8-digit accumulated total counter.

SIGNAL PULSE

"START" BUTTON

"STOP" BUTTON

"RESET" BUTTON

END SIGNAL

"COUNTING"

"SUSPENDED"

"END"

OUTPUT PULSES

BUZZER SOUNDS FOR 1.5 SEC. APPROX.

The circuitry is so configured that definitely a single output pulse is always secured when the“START”or“STOP”button is depressed at any state, any instant of signal pulses. Under no circumstances, therefore, the checker produces spiky or otherwise distorted pulses.

CAUTION:

Page 8: PULSE CHECKER MODEL:PC2201

E-935-1-E

(9)“WIDTH”Select Switch  Selects output pulse width.  “1:1” …… Pulses with 1:1 ON/OFF ratio  “0.25”…… Pulses 0.25ms±10% wide (2000Hz or lower)  “1”  …… Pulses 1ms±10% wide (500Hz or lower)  “50”  …… Pulses 50ms±10% wide (10Hz or lower)

(10)“OUTPUT”Select Switch  Selects the generator type for output pulses.  “OPTO”  …… A simulated output of OPTO 01/02 generator circuit  “PG20”  …… A simulated output of PG20M generator circuit          Coupling conditions are 30V dc and 20mA max. because it provides an open collector output of transistors rather than a relay counterpart.  “PG30”  …… A simulated output of PG30 generator circuit  “P.A.”  …… A simulated output of PA04/05/45 or PG60A (E) generator circuit  “PG30S” …… A simulated output of PG30S generator circuit  “O.C.”  …… A simulated output of FLOWPET NX or PG60A (E) generator circuit  “VOLT”  …… A voltage pulse output from 8V internal power source  “PA11”  …… A simulated output of PA11 generator circuit

Simulated Output Circuit

SUP

SIG

0V

0V

30mA

27240

7K5

5K6

1K2

5K1

5K1

100K

100K

OPTO

PG20

PG30

P.A

PG30S

O.C

VOLT

PA11

OUTPUT

5K1

8V2K4200200

200

220820

Figures in the box □ show the resistance values. (Examples: 100k→100kΩ, �k5→�.5kΩ)

Output frequency should be chosen within the conditions in brackets ( ) when you select a particular fixed pulse width.The ON/OFF ratio is 1/1 when the frequency is at maximum of the figure in the brackets ( ); the OFF width becomes smaller progressively as the frequency exceeds that figure; at frequencies twice that figure, or greater, pulses will overlap and no output will be produced: the "OUTPUT COUNTER" will fail to count.

CAUTION:

Page 9: PULSE CHECKER MODEL:PC2201

E-935-1-E

9

Output Hook-up

SIG

0V

SIG

0V

SIG

0V

SIG

0V

SUP

SIG

0V

Vcc(8.5V)

GND(0V)

1kΩ7.4V5.6V

PC2201

OUTPUT

[OPTO]

Vcc(13.5V)

GND(0V)

10kΩ(RECOMMENDATION)

(R=10kΩ)

(R=10kΩ)

13.4V0.1V[PG20]

[PG30]

Vcc(24V)

GND(0V)

510Ω22.0V14.3V[P.A]

Vcc(13.5V)

30mA

GND(0V)

10kΩ以上6.5V0.1V

Vcc(13.5V)

GND(0V)

510Ω9.6V4.1V[PG30S]

RECEIVINGINSTRUMENT (SIG.WAVEFORM)

Page 10: PULSE CHECKER MODEL:PC2201

E-935-1-E

10

SIG

0V

SIG

0V

SUP

SIG

0V

Vcc(13.5V)

GND(0V)

13.4V0.1V[O. C]

GND(0V)

10kΩ(RECOMMENDATION)

10kΩ(RECOMMENDATION)

(R=10kΩ)

(R=10kΩ)

(R=10kΩ)

5.1V0.1V[VOLT]

[PA11]

Vcc(32V)

GND(0V)

10kΩmin.

31.9V1.0V

30mA

0.25 or 1 or 50ms0.25 or 1 or 50ms

PC2201 RECEIVINGINSTRUMENT (SIG.WAVEFORM)

SIG

0V

SIG

0V

SUP

SIG

0V

Vcc(13.5V)

GND(0V)

13.4V0.1V[O. C]

GND(0V)

10kΩ(RECOMMENDATION)

10kΩ(RECOMMENDATION)

(R=10kΩ)

(R=10kΩ)

(R=10kΩ)

5.1V0.1V[VOLT]

[PA11]

Vcc(32V)

GND(0V)

10kΩmin.

31.9V1.0V

30mA

0.25 or 1 or 50ms0.25 or 1 or 50ms

PC2201 RECEIVINGINSTRUMENT (SIG.WAVEFORM)

・ Voltage levels of signal waveform include an error of ±0.5V.・ Signal waveforms shown here indicate the position of fixed width when a fixed pulse width is chosen.

CAUTION:

・ In case of “PG20”, “O.C.” and “PA11”, because of a 200Ω protective resistor in series with the “SIG” output, voltage level L0 of signal waveform varies with the resistance value of the shunt resistor coupled to the power in the receiving instrument.   Voltage level L0[V]≒ voltage Vcc[V]÷shunt resistance value[Ω]×200[Ω] +PC2201 output transistor “ON” voltage (0 to 0.5)[V]

Page 11: PULSE CHECKER MODEL:PC2201

E-935-1-E

11

5. GENERAL SPECIFICATIONSITEM DESCRIPTION

Generator Accuracy Crystal oscillator 6±0.0001MHz

Power Source2-way - AC adaptor or internal batteriesAC adaptor: 100/V ac±10%, 50/60HzInternal batteries: UM-3 Ni-Cd batteries (700mAh)×6

Power Consumption 5VAmax.Ambient Temperature 0 to+40℃Finish BlackWeight 2 kilograms, approx. (accessories, internal batteries inclusive)

StandardAccessories

Soft case …… 1Carrying strap …… 1AC adaptor (9V dc, 200mA) …… 1External connection cords (terminated with alligator clip and banana plug) …… Red 4, black 2

6. OUTLINE DIMENSIONS

7. STANDARD ACCESSORIES

HANDLE SLOTAC ADAPTOR SLOTPOWER SWITCH SLOT

SOFT CASE1 EA.

ACCESSORY CASE

CARRYING STRAP1 EA.

AC ADAPTOR1 EA.

ALLIGATOR CLIP

BANANA PLUG

RED : 4BLACK: 2

EXTERNAL CORD

SUP SIG SIG GATEOV OV

OUTPUT INPUT

INPUT LEVEL INPUT COUNTER

OUTPUT COUNTER

FUNCTION

OUTPUT WIDTH %SETTER RATING STOP RESET START

PULSE CHECKER PC 2201

PRESET

FREQUENCY RESET

POWER

DC IN

100101

1K10K

3075100

250

150

0.251.1

(ma)

PG30SO. CVOLTPA11

P. APG30PG20

OPTO

PERIODRATIO

10515

COUNT

FREO

36

15

D.C

1.5

(V)

200 15 41

140

Unit:mm

Page 12: PULSE CHECKER MODEL:PC2201

E-935-1-E

All specifications are subject to change without notice for improvement.2019.02 Revised △E-935-1-E (1)