pulsed eddy current - versa integrity...

2
Nondestructive Examination Services PULSED EDDY CURRENT Corrosion under insulation (CUI) is one of the largest problems in the petrochemical industry. Previous methods of inspection were limited to single points of inspection or having to remove insulation. This is not only time consuming but expensive. This is why we are bringing you the next generation of CUI inspections. Introducing the reinvention of Pulsed Eddy Current. Versa Integrity Group is leading the way in cutting edge technology. We have joined forces with Eddyfi to bring their newest and most innovative technology to your doorstep. The Lyft is Pulsed Eddy Current reinvented and allows the inspector to do corrosion mapping without the need to remove insulation. www.versaintegrity.com

Upload: vudan

Post on 24-Mar-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Pulsed Eddy Current - Versa Integrity Groupversaintegrity.com/files/2016-10/nde-pulsed-eddy-current-digital.pdf · Pulsed Eddy Current Like You’ve Never Seen Our inspectors can

Nondestructive Examination Services

PULSED EDDY CURRENT

Corrosion under insulation (CUI) is one of the largest problems in the petrochemical industry. Previous methods of inspection were limited to single points of inspection or having to remove insulation. This is not only time consuming but expensive. This is why we are bringing you the next generation of CUI inspections.

Introducing the reinvention of Pulsed Eddy Current.

Versa Integrity Group is leading the way in cutting edge technology. We have joined forces with Eddyfi to bring their newest and most innovative technology to your doorstep. The Lyft is Pulsed Eddy Current reinvented and allows the inspector to do corrosion mapping without the need to remove insulation.

www.versaintegrity.com

Page 2: Pulsed Eddy Current - Versa Integrity Groupversaintegrity.com/files/2016-10/nde-pulsed-eddy-current-digital.pdf · Pulsed Eddy Current Like You’ve Never Seen Our inspectors can

Pulsed Eddy Current Like You’ve Never SeenOur inspectors can pinpoint damage mechanisms such as erosion and corrosion through up to 6 inches of insulation and temperatures ranging from less than -240 degrees to 930 degrees fahrenheit.

With Pulsed Eddy Current taking such a giant leap forward, Versa is proud to stand behind the Lyft. This technology allows for greater speed and accuracy as well as allowing the technician to spend little time calibrating. Calibration takes only 30 to 45 seconds, giving you reliable and repeatable results. Similar systems in the past have taken much longer and are less accurate overall.

OUR OFFICES

www.versaintegrity.com

BENEFITSCarbon steel structures: -240°F to 930°F Dynamic scanning up to 3” per second Pipe diameter down to 4” Test for CUI through insulation up to 6” thick Test nominal wall thickness of carbon steel up to 1.5” Accurate within +/-10% Repeatable results Corrosion scab measurement capabilities

Detects ID and OD indications Built in encoder for accurate flaw locations Perform point scans or C-scan Not affected by wet insulation Faster than previous technology 3 sizes of probes for optimal accuracy Calibration not user dependent Easy to read reports with detailed C-scan maps

New Orleans Division 504.368.3122

Lafayette Division 337.837.9721

Sulphur Division 337.558.6071

Houston Division 832.433.7942

Pascagoula Division 228.475.8998

Freeport Division 979.864.3401

Orlando Division 407.481.2533

Tampa Division 813.626.0287

Corpus Christi Division 361.215.1704

[email protected]