pumps - · pdf fileopen units, low flow, high head, ... ace 100 pump ideal for water removal...
TRANSCRIPT
![Page 1: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/1.jpg)
PUMPS
![Page 2: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/2.jpg)
2 HANDY HIRE / PUMPS
THE HIRE POWERPUMPING IT UP FOR YOUAT ONE OF OUR HANDY QUEENSLAND LOCATIONS
MINING GOVERNMENT AGRICULTURE & INDUSTRYHandy Hire has made a substantial investment in Queensland’s future. From civil to mining, building, agriculture, industrial and earthmoving industries, the team in green and gold have the capacity and the infrastructure to get you going and keep you going!
Locally and across our State, Handy Hire is proud of the professional working relationships that we currently maintain with Queensland’s major contributors in commerce and in government.
Pumping & Dewatering Want to move large volumes of water fast?
Handy Hire’s range of pumping equipment has got you covered.
• 4” (100mm) to 12” (300mm) units capable of moving 1.2 mega litres per hour.
• Slurry Pumps 4” (100mm) to 12” (300mm).
• Sewage Bypass Pumps 4” (100mm) to 12” (300mm)
Our range of Heavy Industry & Mine Pumps are manufactured in Australia to BMA specifications.
Did you know that Handy Hire hire poly welding units?
We have pontoons for hire: 6m x 3m and 12m x 12m.
PLUS, Handy Hire have electric and site dewatering pumps, shoring boxes and vacuum excavation units.
![Page 3: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/3.jpg)
For further information visit www.handyhire.com.au 3
CONTENTS
4 A100 Compact Open Units, Shut Off Head, 25m Auto Prime - Max Flow 35 l/sec
5 100M Fully Bunded Units, Shut Off Head, 65m Auto Prime - Max Flow 80 l/sec
6 150 Fully Bunded Units, Shut Off Head, 25m Auto Prime - Max Flow 110 l/sec
7 150M Fully Bunded Units, Shut Off Head, 40m Auto Prime - Max Flow 130 l/sec
8 200M Fully Bunded Units, Shut Off Head, 38m Auto Prime - Max Flow 160 l/sec
9 CF32M Open Units, Shut Off Head, 58m Auto Prime - Max Flow 200 l/sec
10 HH80 Open Units, Low Flow, High Head, 110m Shut Off Head - Max Flow 28 l/sec
11 HH125 Fully Bunded Units, Shut Off Head, 140m Auto Prime - Max Flow 138 l/sec
12 HH150 Fully Bunded Units, Shut Off Head, 100m Auto Prime - Max Flow 130 l/sec
13 HH200 Fully Bunded Units, Shut Off Head, 130m Auto Prime - Max Flow 200 l/sec
14 HL250M Fully Bunded Units, Shut Off Head, 125m Auto Prime - Max Flow 330 l/sec
15 H300 Fully Bunded Units, Shut Off Head, 65m Auto Prime - Max Flow 300 l/sec
![Page 4: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/4.jpg)
4 HANDY HIRE / PUMPS
A100ACE 100 PUMP Ideal for water removal from all work sites, small wellpoint dewatering jobs and sewage bypass.• Auto self prime (25 cfm vacuum system)
Factory set to 1960 rpm - 2000 rpm at zero flow
Free Passage Capability:40mm Diameter
Impeller Diameter: 208mm
Static lift with 12m of suction hose
100mm (4”)
30
25
20
15
10
5
0
9876543210
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38l/s
Net
Gen
erat
ed H
ead
(m)
Suct
ion
Lift
(m)
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
2000 50 250 2-Oct 38
Pump Model ACE100 Impeller Type Open
Discharge (mm) 75/100 Material SG Iron
Suction (mm) 75/100 IMP Dia (mm) 185
Max Solid (mm) 40 Prime System Auto Vac
Engine Model Isuzu 4LE2 25 cfm
Min RPM Fixed Weight (kg) 470
Max RPM Fixed Fuel Consumption (L/hr) 2.3 @ 2000 rpm
Fuel Capacity (lt) 55
Run Time @ Full Load (hr) 24
Operationing outside the recommended best settings could result in higher fuel consumption.
![Page 5: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/5.jpg)
For further information visit www.handyhire.com.au 5
100MMINE SPEC PUMP Ideal for water removal from all work sites, wellpoint dewatering and sewage bypass.• Auto self prime (65 cfm vacuum system)• Fully bunded • Front & rear discharge points
Static lift with 12m of suction hose
150mm (6”)100mm (4”)
70
60
50
40
30
20
10
0
8
6
4
2
0 10 20 30 40 50 60 70 80l/s
Net
Gen
erat
ed H
ead
(m)
Suct
ion
Lift
(m)
Pump Model 100M Impeller Type Open
Discharge (mm) 100/150 Material SG Iron
Suction (mm) 100/150 IMP Dia (mm) 285
Max Solid (mm) 40 Prime System Auto Vac
Engine Model Isuzu4LE2 65 cfm
Min RPM 1500 Weight (kg) 470
Max RPM 2400 Noise (db) 65 @ 7m
Fuel Capacity (lt) 55 Fuel Consumption (L/hr) 2.3 @ 2000 rpm
Run Time @ Full Load (hr) 24 Fuel Consumption (L/hr) 6.0 @ 2200 rpm
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1900-2100 100 350 15 65
2100-2300 150 450 15 75
2300-2400 150 550 18 85
Operationing outside the recommended best settings could result in higher fuel consumption.2000rpm
2200rpm
2400rpm
Max Continuous Performance
![Page 6: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/6.jpg)
6 HANDY HIRE / PUMPS
150MINE SPEC PUMP Ideal for water removal from all work sites, wellpoint dewatering and sewage bypass.• Auto self prime (65 cfm vacuum system)• Fully bunded • Front & rear discharge points
Factory set operating speed 2050 rpm at zero flow
NOISE - Sound Pressure Levels(at 2000 rpm) 65.9 dB(A) at 7m(at 2200 rpm) 68.4 dB(A) at 7m
Free Passage Capability:65mm Diameter x 80mm Long
(Elongated Solid)
Impeller DiaD2h = 145mmD2t = 195mm
E = 18°
Static lift with 15m of suction hose
150mm (6”)
200mm (8”)
25
20
15
10
5
0
9876543210
0 10 20 30 40 50 60 70 80 90 100 110l/s
Net
Gen
erat
ed H
ead
(m)
Suct
ion
Lift
(m)
Pump Model 150 Impeller Type Open
Discharge (mm) 150 Material SG Iron
Suction (mm) 150 IMP Dia (mm) 195
Max Solid (mm) 65 Prime System Auto Vac
Engine Model Isuzu4LE2 65 cfm
Min RPM 1500 Weight (kg) 470
Max RPM 2200 Noise (db) 65 @ 7m
Fuel Capacity (lt) 55 Fuel Consumption (L/hr) 2.3 @ 2000 rpm
Run Time @ Full Load (hr) 24 Fuel Consumption (L/hr) 6.0 @ 2200 rpm
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1900-2000 50 200 10 85
2000-2100 50 225 20 100
2100-2200 50 230 25 110
Operationing outside the recommended best settings could result in higher fuel consumption.
2000 rpm
2200 rpm
![Page 7: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/7.jpg)
For further information visit www.handyhire.com.au 7
150MMINE SPEC PUMPIdeal for water removal from all work sites, wellpoint dewatering and sewage bypass.• Auto self prime (65 cfm vacuum system)• Fully bunded • Front & rear discharge points
Static lift with 15m of suction hose
150mm (6”)
200mm (8”)
40
35
30
25
20
15
10
5
0
30
25
20
15
10
5
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150l/s
Net
Gen
erat
ed H
ead
(m)
Suct
ion
Lift
(m)
Pump Model 150M Impeller Type Open
Discharge (mm) 150 Material SG Iron
Suction (mm) 200 IMP Dia (mm) 254
Max Solid (mm) 65 Prime System Auto Vac
Engine Model Isuzu4LE2 65 cfm
Min RPM 1500 Weight (kg) 470
Max RPM 2200 Noise (db) 65 @ 7m
Fuel Capacity (lt) 55 Fuel Consumption (L/hr) 2.3 @ 2000 rpm
Run Time @ Full Load (hr) 24 Fuel Consumption (L/hr) 6.0 @ 2200 rpm
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1900-2000 50 300 20 120
2100-2200 50 325 30 125
2000-2200 50 400 10 130
Operationing outside the recommended best settings could result in higher fuel consumption.
2000 rpm
2200 rpm
![Page 8: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/8.jpg)
8 HANDY HIRE / PUMPS
200MMINE SPEC PUMP Ideal for water removal from all work sites, bulk water transfer and sewage bypass.• Auto self prime (65 cfm vacuum system)• Fully bunded • Front & rear discharge points
Factory set operating speed 2050 rpm at zero flow
Static lift with 12m of suction hose
200mm (8”)
40
35
30
25
20
15
10
5
0
10
8
6
4
2
0
0 20 40 60 80 100 120 140 160l/s
302520151050
Net
Gen
erat
ed H
ead
(m)
Suct
ion
Lift
(m)
Suct
ion
Lift
(ft)
Min Continuous Flow
2000 rpm
2100 rpm
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1800-1900 50 300 20 120
1900-2000 50 325 25 135
2000-2100 50 400 30 140
Pump Model 200M Impeller Type Open
Discharge (mm) 200 Material SG Iron
Suction (mm) 200 IMP Dia (mm) 245
Max Solid (mm) 75 Prime System Auto Vac
Engine Model Isuzu 4LE2 65 cfm
Min RPM 1500 Weight (kg) 470
Max RPM 2100 Noise (db) 65 @ 7m
Fuel Capacity (lt) 55 Fuel Consumption (L/hr) 2.3 @ 2000 rpm
Run Time @ Full Load (hr) 24 Fuel Consumption (L/hr) 6.0 @ 2100 rpm
Operationing outside the recommended best settings could result in higher fuel consumption.
![Page 9: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/9.jpg)
For further information visit www.handyhire.com.au 9
70
60
50
40
30
20
10
0
10
5
CF32M
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220
NPS
H (m
)
Flow Rate (l/s)
2000 rpm
2000 rpm
1900 rpm
1800 rpm
1700 rpm
1600 rpm
1500 rpm
1500 rpm
30 kW
40 kW50 kW
60 kW70 kW
80 kW
30% 40% 50% 60% 70% 75% 77%79%
79%78%
77%75%
Pump Model CF32M Impeller Type Open
Discharge (mm) 200 Material 316 S/S
Suction (mm) 200 IMP Dia (mm) 316
Max Solid (mm) 25 Prime System Auto
Engine Model Cat C4.4
Min RPM 1500
Max RPM 2000
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1500-1600 220 300 50 150
1700-1800 300 450 60 160
1900-2000 450 550 80 160
Operationing outside the recommended best settings could result in higher fuel consumption.
![Page 10: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/10.jpg)
10 HANDY HIRE / PUMPS
HH80 Pump Model HH80 Impeller Type Open
Discharge (mm) 75/100 Material S/Steel
Suction (mm) 75/100 IMP Dia (mm) 325
Max Solid (mm) 40 Prime System CP
Engine Model C3.3T 15 cfm
Min RPM 1400 Weight (kg) 1050
Max RPM 2400 Noise (db) 80 @ 7m
Fuel Capacity (lt) 55
Run Time @ Full Load (hr) 24-30
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1900-2100 100 350 8 25
2100-2300 150 450 8 25
2300-2400 150 550 8 25
Operationing outside the recommended best settings could result in higher fuel consumption.
110
100
90
80
70
60
50
40
30
20
10
0
360
330
300
270
240
210
180
150
120
90
60
30
0
2
4
6
8
8
6
4
2
Hea
d (m
)
Hea
d (f
t)
Suct
ion
Lift
(m)
Flow Rate (l/s)
NPS
HR
(m)
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Note: Power Curve includes Air Compressor Power Consumption
1400 rpm
12 kW17 kW
22 kW28 kW
33 kW
38 kW
43 kW
48 kWB.E.P.
1500 rpm1600 rpm1700 rpm1800 rpm1900 rpm2000 rpm2100 rpm2200 rpm2300 rpm2400 rpm
![Page 11: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/11.jpg)
For further information visit www.handyhire.com.au 11
HH125SPEC’S 1000 KPA UNIT• 36 hour fuel tank • Multi point lifting frame • Single drop discharge • Bauer couplings• Heavy duty bullbar / push bar • Engine canopy • 4.8m boom & winch• 6” butterfly valve • Vacuum suction gauge • Discharge pressure gauge• Loss of flow shutdown • Lockable battery isolator • Jump start receptacle• Fire extinguisher • Wiggins fast fill system • Bis-alloy wear strips • Emergency stop buttons - 3 sides • Exhaust heat shielded
Litres per second 27.7 55.5 83.3 111 138Cubic metres per hour 100 200 300 400 500
140
120
100
80
60
40
20
0
Hea
d in
Met
res
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1600-1800 450 950 50 110
1700-1800 650 1150 80 120
Pump Model HH125 Type: 5 Vane Closed
Discharge (mm) 200 Material SC
Suction (mm) 200 IMP Dia (mm) 400
Max Solid (mm) 42 Prime System Auto Vac
Engine Model CTA8.3
Min RPM 1600
Max RPM 2000
2200rpm
2000rpm
1800rpm
1600rpm
1000rpm
73%BEP 75%
70%
Operationing outside the recommended best settings could result in higher fuel consumption.
![Page 12: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/12.jpg)
12 HANDY HIRE / PUMPS
HH150SPEC’S 1000 KPA UNIT
1500
1400
1600
1700
1800
1900
2000
Litres per second 40 50 60 70 80 90 100 110 120Cubic metres per hour 144 216 288 360 432
100
90
80
70
60
50
40
30
20
10
0
Hea
d in
Met
res
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1500-1600 400 650 40 100
1700-1800 600 800 40 100
1900-2000 800 950 40 90
Pump Model HH150S Type: 6 Vane Closed
Discharge (mm) 200 Material A49
Suction (mm) 200 IMP Dia (mm) 365
Max Solid (mm) 40 Prime System Auto Vac
Engine Model CTA8.3
Min RPM 1400
Max RPM 2000
Operationing outside the recommended best settings could result in higher fuel consumption.
4m 6m5m 8mNPSH
65%
68%
65%60%
eff
• 36 hour fuel tank • Single point lifting frame • Single drop discharge • Bauer couplings• Heavy duty bullbar / push bar • Engine canopy • 4.8m boom & winch• 6” butterfly valve • Vacuum suction gauge • Discharge pressure gauge• Loss of flow shutdown • Lockable battery isolator • Jump start receptacle• Fire extinguisher • Wiggins fast fill system • Bis-alloy wear strips • Emergency stop buttons - 3 sides • Exhaust heat shielded
![Page 13: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/13.jpg)
For further information visit www.handyhire.com.au 13
HH200SPEC’S 1000 KPA UNIT
1350
1200
1500
1650
1750
Litres per second 50 75 100 125 150 175 200Cubic metres per hour 180 350 540 730
130
120
110
100
90
80
70
60
50
0
Hea
d in
Met
res
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1200-1500 450 600 50 175
1500-1600 600 900 50 200
1600-1750 900 1250 50 200
Pump Model HH200 Type: 6 Vane Closed
Discharge (mm) 215 TE Material A49
Suction (mm) 315 TE IMP Dia (mm) 720
Max Solid (mm) 50 Prime System Auto Vac
Engine Model QSM15
Min RPM 1200
Max RPM 1750
Operationing outside the recommended best settings could result in higher fuel consumption.
2m 4m 6m 7m 8m
65%
65%
68%
60%50%
Curve characteristics based on clear water
• 36 hour fuel tank • Single point lifting frame • Single drop discharge • Bauer couplings • Heavy duty bullbar / push bar • Engine canopy • 4.8m boom & winch • 6” butterfly valve • Vacuum suction gauge • Discharge pressure gauge • Loss of flow shutdown • Lockable battery isolator • Jump start receptacle • Fire extinguisher • Wiggins fast fill system • Bis-alloy wear strips • Emergency stop buttons - 3 sides • Exhaust heat shielded
![Page 14: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/14.jpg)
14 HANDY HIRE / PUMPS
HL250M
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1200-1400 200 600 50 222
1400-1600 300 750 83 250
1600-1900 450 1100 100 300
Pump Model HL250M Type: Open
Discharge (mm) 215 TE Material SC
Suction (mm) 315 TE IMP Dia (mm) 440
Max Solid (mm) 65 Prime System Auto Vac
Engine Model QSM15
Min RPM 1200
Max RPM 1900
Operationing outside the recommended best settings could result in higher fuel consumption.
140130120110100
908070605040302010
0
4504203903603303002702402101801501209060300
8
6
4
2
0
25
20
15
10
5
0
Hea
d (m
)
Hea
d (f
t)
Hea
d (m
)
Flow Rate (l/s)
NPS
H
0 28 55 83 110 138 166 195 222 250 278 305 330 360
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacity limitation
Add 0.5 metres of NPSHr or all field applications
50%65%
72%
72%68%
62%52%
41%
74%
Maximum capacity limitation
![Page 15: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/15.jpg)
For further information visit www.handyhire.com.au 15
H300SPEC’S 1000 KPA UNIT
Curve characteristics based on clear water
1100
1100
1200
1350
1500
1650
Litres per second 100 150 200 250 300Cubic metres per hour 360 540 730 900 1080
65
60
55
50
45
40
35
30
25
20
0
Hea
d in
Met
res
BEST SETTING FLOW L/S
Engine RPM Min KPA Max KPA Min Max
1100-1400 200 450 100 175
1400-1500 450 525 100 275
1500-1650 550 650 100 300
Pump Model H300 Type: 6 Vane Closed
Discharge (mm) 215 TE Material A49
Suction (mm) 315 TE IMP Dia (mm) 720
Max Solid (mm) 50 Prime System Auto Vac
Engine Model QSM15
Min RPM 1100
Max RPM 1650
Operationing outside the recommended best settings could result in higher fuel consumption.
3m 4m 6m 8m
NPSH
10m
70%
73%
70%65%60%
• 36 hour fuel tank • Single point lifting frame • Single drop discharge • Bauer couplings • Heavy duty bullbar / push bar • Engine canopy • 4.8m boom & winch • 6” butterfly valve • Vacuum suction gauge • Discharge pressure gauge • Loss of flow shutdown • Lockable battery isolator • Jump start receptacle • Fire extinguisher • Wiggins fast fill system • Bis-alloy wear strips • Emergency stop buttons - 3 sides • Exhaust heat shielded
![Page 16: PUMPS - · PDF fileOpen Units, Low Flow, High Head, ... ACE 100 PUMP Ideal for water removal from all work sites, ... Impeller Diameter: 208mm Static lift with 12m of suction hose](https://reader035.vdocuments.net/reader035/viewer/2022062907/5aaf300c7f8b9a22118cef43/html5/thumbnails/16.jpg)
HERVEY BAY68 Boat Harbour DrivePialba QLD 4655Phone: (07) 4128 1655Fax: (07) 41282810
MARYBOROUGH74 Ferry StreetMaryborough QLD 4650Phone: (07) 4121 3488Fax: (07) 4121 3088
BUNDABERG6 Princess StreetBundaberg QLD 4670Phone: (07) 4153 4455Fax: (07) 4152 7955
GYMPIE17 Hall RoadGympie QLD 4570Phone: (07) 5483 9777Fax: (07) 5483 9422
www.handyhire.com.au
Handy Hire endeavours to provide the equipment as referred to and pictured in this booklet. However all equipment is subject to availability at the time of hire. Depending upon the situation at that time, Handy Hire would make available another machine or piece of equipment of similar specification and capacity. Customers can be certain that the alternative will be equivalent to the item depicted in this booklet. All information regarding equipment detailed in this booklet is accurate to the best of our knowledge at the time of printing, but Handy Hire advises customers to confirm specifics at the point of hire or enquiry. Handy Hire reserves the right to alter information without prior advice.
Promotions Pro - 01/2013