Regulation 5 states: (1) Every employer shall ensure that work equipment is maintained in an efficient state, in efficient working order and in good repair. (2) Every employer shall ensure that where any machinery has a maintenance log, the log is kept up to date. PUWER Regulations - Are you compliant? Are your sluice room macerators compliant with the Provision and Use of Work Equipment Regulations (PUWER) 1998 ? Vernacare can help you achieve compliance The ‘efficient state’ of a macerator refers to its general safe condition, for example: having enclosure which is not damaged or broken; no water leaks. Checking whether a macerator is in ‘efficient working order’ means checking to ensure that everything designed for safety works as it is meant to. This includes: machine properly earthed, lid seal not leaking, safety switches and circuitry operational. To be ‘in good repair’ a macerator needs to be Periodically Maintained and the results recorded in a maintenance log.

Upload: others

Post on 27-Jun-2020

8 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: PUWER Regulations - Are you compliant? · PUWER Regulations - Are you compliant? Are your sluice room macerators compliant with the Provision and Use of Work Equipment Regulations

Regulation 5 states:

(1) Every employer shall ensure that work equipment is maintained in an efficient state, in efficient working order and in good repair.

(2) Every employer shall ensure that where any machinery has a maintenance log, the log is kept up to date.

PUWER Regulations - Are you compliant?Are your sluice room macerators compliant with the Provision

and Use of Work Equipment Regulations (PUWER) 1998 ?

Vernacare can help you achieve compliance

The ‘efficient state’ of a macerator refers to its general safe condition, for example: having enclosure which is not damaged or broken; no water leaks.

Checking whether a macerator is in ‘efficient working order’ means checking to ensure that everything designed for safety works as it is meant to. This includes: machine properly earthed, lid seal not leaking, safety switches and circuitry operational.

To be ‘in good repair’ a macerator needs to be Periodically Maintained and the results recorded in a maintenance log.

Page 2: PUWER Regulations - Are you compliant? · PUWER Regulations - Are you compliant? Are your sluice room macerators compliant with the Provision and Use of Work Equipment Regulations

Folds Road

Bolton BL1 2TX T: +44 (0) 1204 529494

Fax: +44 (0) 1204 521862

E: [email protected]

www.vernacare.com

Contact us for more information

Vernacare’s Service Contract includes:

20% discount on genuine Vernacare spare parts

Emergency priority over non contract customers

Basic engineering training on first line fixes

Replacement of machine diaphragm at engineer’s discretion Inspection of all electrical and mechanical components, including the motor, diaphragm, pump and pipe work and lid seals

Vernacare offer sluice room macerator audits, review and service contracts to deliver PUWER compliance on all sluice room macerators at your site, including Vortex machines and other brands.

Contact us today

on 01204 555999