q1000 product sheet

4
Maximize your Measurement Intelligence Unsurpassed Accuracy QUANTUM Q1000 provides you with the information to deliver energy predictably and reliably. This revolutionary meter meets worldwide requirements for accuracy, reliability, and connectivity. The information technology and standards are all based on our experience with proven QUANTUM meter engineering. The SchlumbergerSema QUANTUM Q1000 is a solid-state electronic multimeasurement, transformer-rated, polyphase meter of unsurpassed accuracy designed to be used at bulk power flow points, including power plants, substations, intertie points, and large commercial and industrial sites. The Q1000 meter measures and displays the per phase real and reactive power in all four quadrants along with thousands of other values. Active transformer technology combined with a 14-bit analog-to-digital converter reduces measurement errors to near reference standard levels. Each Q1000 meter meets or exceeds the accuracy standards for IEC 60687 for 0.2S and ANSI C12.20: 1997 for class 0.2 meters. The Q1000 has been tested and approved by many internationally recognized laboratories in conjunction with local utilities. Among these are: in the United States: California ISO, New England ISO, Texas ISO-ERCOT, and Demand Side Solutions, Inc.; in Canada: Measurement Canada, Ontario IMO, and Subnet Solutions; in Netherlands: KEMA Registered Quality B.V. Calibration Laboratory and NMi Netherlands Meetinstitute; in Mexico: Comision /Federal De Electricidad and LAPEM; in Argentina: INTI; in Spain: Red Electrica De Espana; in France: Electricite De France. The Q1000 meter is available in Socket, Rackmount, Switchboard, DIN, A-base, and DIN Flushmount configurations. Each configuration is available in form five [3 phase 3 wire delta, (2 element)] and form nine [3 phase, 4 wire wye (3 element)]. Flexible Communications QUANTUM Q1000 works the way you work, featuring flexible input and output capabilities and a wide range of software options. The QUANTUM Q1000 is equally versatile in multiple high speed communications, from frame relay and fiber optics to radio, phone, dial-up, and microwave using DNP 3.0, IEC 60870-5-102, IEC 60870-5-102 plus, mini-DLMS, and MODBUS ® protocols. Protocols. The Q1000 meter has powerful, flexible protocols, enabling you to connect to a variety of systems.This flexibility allows easy coordination with existing systems. Dependable Support SchlumbergerSema backs QUANTUM Q1000 with the reliable support you expect from the leading solutions provider to electric utilities. Our engineers work with you to implement the QUANTUM Q1000 in the field and tailor its software to provide the intelligent, real-time information you need. The QUANTUM Q1000 meter is available in socket, rackmount, switchboard, DIN, and A-base configurations. QUANTUM ® Q1000 Electronic Multimeasurement Meter

Upload: api-27293273

Post on 11-Apr-2015

871 views

Category:

Documents


11 download

TRANSCRIPT

Page 1: Q1000 Product Sheet

Maximize your Measurement Intelligence

Unsurpassed Accuracy

QUANTUM Q1000 provides you with theinformation to deliver energy predictablyand reliably. This revolutionary metermeets worldwide requirements foraccuracy, reliability, and connectivity.The information technology andstandards are all based on ourexperience with proven QUANTUMmeter engineering.

The SchlumbergerSema QUANTUMQ1000 is a solid-state electronicmultimeasurement, transformer-rated,polyphase meter of unsurpassedaccuracy designed to be used at bulkpower flow points, including powerplants, substations, intertie points, andlarge commercial and industrial sites.The Q1000 meter measures and displaysthe per phase real and reactive power inall four quadrants along with thousandsof other values.

Active transformer technology combinedwith a 14-bit analog-to-digital converterreduces measurement errors to nearreference standard levels. Each Q1000meter meets or exceeds the accuracystandards for IEC 60687 for 0.2S andANSI C12.20: 1997 for class 0.2 meters.

The Q1000 has been tested andapproved by many internationallyrecognized laboratories in conjunctionwith local utilities. Among these are: inthe United States: California ISO, NewEngland ISO, Texas ISO-ERCOT, andDemand Side Solutions, Inc.; in Canada:Measurement Canada, Ontario IMO, andSubnet Solutions; in Netherlands: KEMA

Registered Quality B.V. CalibrationLaboratory and NMi NetherlandsMeetinstitute; in Mexico: Comision /FederalDe Electricidad and LAPEM; in Argentina:INTI; in Spain: Red Electrica De Espana; inFrance: Electricite De France.

The Q1000 meter is available in Socket,Rackmount, Switchboard, DIN, A-base, andDIN Flushmount configurations. Eachconfiguration is available in form five [3phase 3 wire delta, (2 element)] and formnine [3 phase, 4 wire wye (3 element)].

Flexible Communications

QUANTUM Q1000 works the way youwork, featuring flexible input and outputcapabilities and a wide range of softwareoptions. The QUANTUM Q1000 is equallyversatile in multiple high speedcommunications, from frame relay andfiber optics to radio, phone, dial-up, andmicrowave using DNP 3.0, IEC 60870-5-102,IEC 60870-5-102 plus, mini-DLMS, andMODBUS® protocols.

Protocols.

The Q1000 meter has powerful, flexibleprotocols, enabling you to connect to avariety of systems.This flexibility allowseasy coordination with existing systems.

Dependable Support

SchlumbergerSema backs QUANTUMQ1000 with the reliable support youexpect from the leading solutionsprovider to electric utilities. Our engineerswork with you to implement theQUANTUM Q1000 in the field and tailorits software to provide the intelligent,real-time information you need.

The QUANTUM Q1000meter is available insocket, rackmount,switchboard, DIN, andA-base configurations.

QUANTUM® Q1000 ElectronicMultimeasurement Meter

Page 2: Q1000 Product Sheet

2

QUANTUM® Q1000 Electronic Multimeasurement Meter

Key Features• Class 0.1% accuracy• Optical communication port, two

RS-232 communication ports, andI/O port can be used simultaneously

• Up to ten load profiles with 24 channels each enabling a variety ofinterval length choices for energyquantities

• TOU- Current (active) Schedule- Latent (pending) Schedule- Seven day types- Seven rates plus total- Many daily patterns- Many switch points- Up to 16 digital state triggered

TOU events- Up to 12 independent seasons

per year- Many years- Many holidays- Supports simultaneous active TOU

rates (overlapping)- Supports temporary overrides of

Current TOU Schedule• Advanced Protocols DNP 3.0,

MODBUS RTU• Reconfiguration

- Communication- Daylight Savings Time- Harmonics- Input Configuration- LED Operation- Security Codes- Voltage Quality- Current Time of Use- Latent Time of Use

• System loss compensation (SLC)• Update meter time +/- one hour

independently of other meterfunctions

• GPS time synchronization• Detection and recording of voltage

sags, swells, imbalances, andinterruptions

• Detection and measurement of 2nd to 32nd harmonics with recording of and display 2nd

to 20th harmonics• Splitter cable that separates

I/O wires (2); two RS-232 com ports(DB-25 connector, each); RS-485 com port wires (5)

• Eight totalized quantities (additive, subtractive, and SQRT sum-of-the-squares)

• Flexible user memory

The Q1000 meter is capable ofcalculating, recording, and displayingthe following registers:

Energy• Wh: net, delivered, received, per

phase, and aggregate• VARh: delivered, received, 4-quadrant,

per phase, and aggregate• VAh: vectorial and arithmetic, 4-quadrant,

delivered, received, per phase,aggregate, distortion, and unbalance

• PFh: per phase and aggregate• Hzh• Qh: net, delivered, and received• Ih and I2h: per phase, neutral, and

average• Vh and V2h: per phase and average• Ih: per phase, % THD, ANSI, and

IEC versions• Vh: per phase, % THD, ANSI, and

IEC versions• Energy values are programmable for

per phase and three phase data

DemandMaximum and minimums, present,previous, projected, cumulative,continuous cumulative, and selectablecoincident demand values

Demand Register Types• Block and rolling demand intervals

with programmable interval and subinterval lengths.

• Thermal demand calculations• Demand intervals are synchronized to

the internal clock.• Demand values are programmable

for per phase and three phase data.

Instantaneous• Net, delivered, received, per phase,

and aggregate• Instanteneous peaks and minimums

Self ReadUp to 32 sets of self read data, each setwith up to 60 registers.

Standard Features• Class 0.1% Accuracy• 7 Rate TOU• Flexible User Memory• Quad-Port Communications (QDIP,

mini-DLMS protocols included)• 1 Load Profile (24 channels)• 32 I/O Capability (supports one module of

each type - purchase separately.)• System Loss Compensation• 1 Splitter Communications Cable• Additional options are: AC/DC Auxiliary

Power, Meter Form, Optical Port Type,LED Type, Operating Frequency, andCurrent Class Rating.

Optional Features• Digital state inputs and outputs• KY/KYZ digital pulse inputs and outputs• Voltage and current analog outputs• Support for advanced protocols,

including DNP 3.0, IEC 60870-5-102, IEC 60870-5-102 Plus, and MODBUS (RTU) protocols

• Hardened internal 33,600 bps modem option board

• Autoranging AC/DC auxiliary powersupply

• Hardened 4 wire RS-485/RS-232 option board

I/O Network

• The I/O modules are separate and completemodules. Each module interfaces to themeter through a twisted pair of wiresutilizing Echelon's LonWorks® protocol.

• The Q1000 plug and play meters can beconfigured to use the following functionsthrough the use of I/O modules:- 8 pulse outputs- 8 pulse inputs- 16 digital state outputs- 16 digital state inputs- 8 analog outputs- 8 analog inputs(1)

Meter Rated Voltage TableForm 5 {3 phase, 3 wire delta (2 element)] Phase to Phase VoltageSocket58-69V* 100-120V 220-240VDIN/DIN Flushmount/A-base/Switchboard/Rackmount58-69V* 100-120V 220-240VForm 9 [3 phase, 4 wire wye (3 element)] Phase to Neutral VoltageSocket58-69 V* 100-120V 220-240VDIN/DIN Flushmount/A-base/Switchboard/Rackmount58-69V 100-120V 220-240V*

Voltage Input Ratings

* Meters operating within these ranges are only available when ordered with auxiliary power.

Page 3: Q1000 Product Sheet

3

QUANTUM® Q1000 Electronic Multimeasurement Meter

• The quantities, pulse weights, events,demand, and zero offset are userprogrammable.

• Standard system supports a 500 foot I/ONetwork. Call for longer distances.

(1) This module is not yet available.

Internal Modem

• 33,600 bps modem• Auto-baud sensing capability• Can be configured as either an

auto-answer or an auto-dial unit• Off-hook detect allows modem to release

phone line if extension phone picks up• Supports up to 32 meters on one phone

line

Advanced Protocols

• DNP 3.0, Level 2+ • IEC 60870-5-102+ • IEC 60870-5-102 • MODBUS® RTU

Software• Compatible with ITRON® MV-90• PC-PRO+® 98• Protocol Editor™

• HHF meter data file creation with PC-PRO+ 98 version 5.0 or greater

• EnergyAudit™ 5.0• Compatible with DC Systems RTscada™,

for real-time applications

Product AvailabilityHardware Mounting

• Q1000 Socket: Form 5, Form 9• Q1000 DIN: Form 5, Form 9• Q1000 Switchboard: Form 5, Form 9• Q1000 Rackmount: Form 5, Form 9• Q1000 A-base: Form 5, Form 9• Q1000 DIN Flushmount: Form 5, Form 9

Current Input Ratings

• ANSI Class 10, ANSI Class 201

• IEC In=5A, Imax=10A • IEC In=5A, Imax=20A1

• ANSI Class 22

• IEC In=1A, Imax=6A2

1 Rackmount meter available in 10A and low

current ranges.2 Low current version available in Socket, Rackmount,

Switchboard, DIN, DIN Flushmount and A-base Forms.

Auxiliary Power Ratings

1 phase AC or two wire DC 100-240V

Specifications• Current Range: 0 to class amps • Test Amps: 0.5 class amps • Starting Current:

1A meters: <1mA10A meters: <5mA20A meters: <5mA

• Voltage Range: -20% to +25% ofnominal voltage

• Frequency Range:57-63 Hz (60 Hz setting)47-53 Hz (50 Hz setting)

• Temperature Range: -40˚C to +85˚C• Humidity Range: 0 to 95%, non-

condensing

Reference Conditions for Accuracy Data• Voltage: nominal voltage +/- 3%• Current: In to class amps• Temp: +23˚C +/-3˚C• Frequency: As rated (50 or 60 Hz)• Waveform: Distortion factor

less than 3%

Reference Information• QUANTUM® Q1000 Meter Technical

Reference Guide, Revision 2.0• QUANTUM® Q1000 Online

Technical Reference Guide• PC-PRO+® 98 Getting Started Guide• PC-PRO+® 98 Help Files• Protocol Editor™ Help files• Protocol Editor™ Getting Started Guide

Technical DataGeneral International Codes:

Conforms to:• ANSI C12.1: 1995• ANSI C12.20: 1998• ANSI/UL 50:1992• ASTM B117:1994• ASTM D999:1991• IEC 60687 (1992-06)• IEC 60068-2-6 (1995-03)• IEC 60068-2-27 (1987-06)• IEC 61268

The Q1000 meets ANSI C12.1 with the exception ofSection 4.7.2.8 “Meter Losses” and section 4.7.2.13“Radio Frequency Conducted and RadiatedEmission.”

Surge, Impulse, and RF Interference

Conforms to:• ANSI C37.90.1: 1989• ANSI C62.41: 1991• FCC Part 15• FCC Part 68• IEC 61000-4-2 (1995-01)• IEC 61000-4-4 (1995-01)

Accuracy Tests

In conformance with the IEC 60687standard for class 0.2S meters, as wellas ANSI C12.16 for class 0.2 meters

Measured Quantity Phase Angle % Error of Reading

Volts (0.75Vn-1.15Vn) All Phase Angles +/- 0.2%Amps (0.1A-0.25A) All Phase Angles +/- 0.4%Amps (0.25A-5A) All Phase Angles +/- 0.2%Watts (0.05A-0.25A) 0˚, 180˚ +/- 0.2%Watts (0.25A-20A) 0˚, 180˚ +/- 0.1%Watts (0.1A-0.5A) -60˚, +60˚, -120˚, +120˚ +/- 0.3%Watts (0.5A-20A) -60˚, +60˚, -120˚, +120˚ +/- 0.2%Vars (0.05A-0.25A) -90˚, +90˚ +/- 0.2%Vars (0.25A-20A) -90˚, +90˚ +/- 0.1%Vars (0.1A-0.5A) -30˚, +30˚, 150˚, +150˚ +/- 0.3%Vars (0.5A-20A) -30˚, +30˚, 150˚, +150˚ +/- 0.3%Q(0.05A-0.25A) -60˚ +120˚ +/- 0.4%Q(0.25A-20A) -60˚ +120˚ +/- 0.3%Q(0.1A-0.5A) -30˚, +30˚, 150˚, +150˚ +/- 0.6%Q(0.5A-20A) -30˚, +30˚, 150˚, +150˚ +/- 0.4%VA Arith. (0.05A-0.25A) All Phase Angles +/- 0.3%VA Arith. (0.25A-20A) All Phase Angles +/- 0.4%VA Vec. (0.1A-0.5A) -60˚, +60˚, -120˚, +120˚ +/- 0.3%

-30˚, +30˚, -150˚, +150˚VA Vec. (0.5A-20A) -60˚, +60˚, -120˚, +120˚ +/- 0.3%

-30˚, +30˚, -150˚, +150˚

Accuracy DataThe Q1000 meter is a +/-0.1% accuracy device complying with the requirements of IEC 60687(1992-06) for 0.2S meters and ANSI C12.20:1997 for class 0.2 meters.

Page 4: Q1000 Product Sheet

SchlumbergerSema Energy & Utilities 313-B North Highway 11West Union, SC 29696, USATel: (864) 638-8300Fax: (864) 638-4950

© 2002 SchlumbergerSema Inc.

www.goslb.com

Dimensions

Q1000 Switchboard Meter

Q1000 Socket Meter

Q1000 A-Base Meter

Q1000 DIN Meter (with short cover)*

Effective Date: July 2002

GTD-Q1K-0066-07.02QUANTUM and PC-PRO+ are registered trademarks and Protocol Editor is a trademark of SchlumbergerSema Inc. LONWORKS is a trademark of Echelon Corporation.MODBUS is a trademark of Proticon. RTscada is a trademark of DC Systems.

Q1000 Rackmount Meter

All dimensions are in centimeters and (inches)

* Long cover available

SchlumbergerSema Energy & Utilities6700 Century Avenue, Suite 100Mississauga, Ontario L5N 2V8 CanadaTel: (905) 812-2227Fax: (905) 812-5028