qti brochure
TRANSCRIPT
8/10/2019 QTI Brochure
http://slidepdf.com/reader/full/qti-brochure 1/4
Waste Gas Management
Incineration System
Portable UnitsCoalbed Methane
Well Testing Workovers
Early Production TestingPipeline blowdowns
Landfill Waste Gas
Permanent Units Acid Gas & Tail Gas DestructionDehydration ApplicationsSolution GasShale Gas
Waste Water TreatmentFlue Gas Destruction
QUESTOR TECHNOLOGY INC.
For and on behalf of:
8/10/2019 QTI Brochure
http://slidepdf.com/reader/full/qti-brochure 2/4
Waste Gas Handling
Starrenburglaan 11a 2251AG Voorschoten
The Netherlands G.I. Dynamics B.V. Kvk: 27372897
Tel: +31 (0)71 56 202 56 Fax: +31 (0)71 56 227 57
[email protected] www.gidynamics.nl
Waste Gas Management
KEY ADVANTAGES OF OUR INCINERATION SYSTEM:
Environmental Impact The incinerators combust waste gas streams at an efficiency rate of
>99.99% thereby converting waste streams to less hazardous and
manageable emissions, such as carbon dioxide, water vapour and
sulfur dioxide.
Complete Combustion for H2S and Rich Gases (>99,99%)Many clients including Shell, ExxonMobil, Vaquero, Dominion Explo-
ration and others have demonstrated that our incineration units
reach a true combustion efficiency of >99.99% when combusting H2S
to SO2.
Low Heat Gas Content (low-BTU)It is a proven technology in saving clients’ money by the use of opti-
mal volumes of fuel for cases where the gas composition has a low
heat value.
Close Spacing The incineration units are equipped with a number of safeguards that
prevent any communication between the internal incinerator process
and the environment external to the incinerator. It is these featuresthat allow the incinerator to be placed immediately adjacent to the
other process equipment.
Low Ground Level Heat RadiationLow level ground heat radiation allows for facility integration as well
as ensuring the safety of personnel.
W A
S T E G A S H A N D L I N G F O R
W I D E R A N G E O F A P P L
I C A T I O N S
8/10/2019 QTI Brochure
http://slidepdf.com/reader/full/qti-brochure 3/4
Waste Gas Handling
Well Test, Sinopec China, North-East Sichuan Province
20 MMSCFD of 18% H 2S AND 10% CO2Q3000 Incinerator Units
Starrenburglaan 11a 2251AG Voorschoten
The Netherlands G.I. Dynamics B.V. Kvk: 27372897
Tel: +31 (0)71 56 202 56 Fax: +31 (0)71 56 227 57
[email protected] www.gidynamics.nl
mprovement of air quality is one of the key concerns
to sustainable development worldwide. As strict
environmental regulations are being enacted to
protect the public and minimize harmful atmosphericemissions, our clients look to our business partner to
develop solutions that meet regulatory compliance and
allow them to operate cost effectively in an environmen-
tally responsible and sustainable manner.
I
Incineration Technology
Unique Design
The proprietary gas burner control creates a high velocity
vortex. The waste and fuel gas streams enter the incinerator
through nozzles designed to alter the direction of the flows insuch a way as to create a high energy vortex. The efficient
mixing results in a highly efficient use of fuel, air and
hydrocarbon which results in elevated combustion
temperatures and >99.99
combustion efficinecy.
Questor specializes in
sweet and sour
hydrocarbon waste gas
incineration at well testsites and at facilities and
works jointly with clients to
design for their specific
application and to ensure
compliance with
environemtal regulations.
Refractory Lining
Questor incinerators are re-
fractory lined which retains
heat and minimizes losses
from combustion to stack exit.
The incineration units can be
equipped with a heat
exchanger creating the
possibility for capturing the
heat and transform it into
power.
No visible flame
Not effected by liquid droplet size
High temperatures efficiently burn
rich gas. Air pre-mixed with thewaste gas prior to combustion
Combustion occurs in a closed
chamber unaffected by winds
Measured independently at
>99.99% consistently
Incineration TechnologyTraditional Flare
Visible Flame
Entrained liquid droplets decreasecombustion efficiency
Difficulty burning rich gases oftenproducing soot deposits and black
smoke (BTEX, VOC, PAH)
Heavily influenced by crosswindsallowing gases to escape unburned
Difficult to measure efficiency and
varies from site to site
Waste Gas Management
8/10/2019 QTI Brochure
http://slidepdf.com/reader/full/qti-brochure 4/4
北京市朝阳区曙光西里甲一号,第三置业(东域大厦)
B座1205室,100028 荷兰吉德工业公司
电话 +86 (0)10 84 053 693
[email protected] www.gidynamics.cn
Contact UsFor more information about the technology and applications, don’t hesitate to
contact our business associates. We would be glad to help you in achieving
sustainable business!
Adrian R. Toader
Starrenburglaan 11a 2251AG Voorschoten
The Netherlands G.I. Dynamics B.V. Kvk: 27372897
Tel: +31 (0)71 56 202 56 Fax: +31 (0)71 56 227 57
[email protected] www.gidynamics.nl
QUESTOR TECHNOLOGY INC.