Quaesta Instruments

• Tucson Arizona• Founded in 2008• Staff: 10• Electronic devices:

• radiation detection• environmental monitoring• data logging• telemetry

• Off-the-shelf and custom products

Page 2: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

• Neutron Pulse Monitors- Proportional gas detectors

• Data logging devices

• Environmental sensors

• Mobile neutron detectors

• Soil moisture monitoring stations (radiation based)

Products

Page 3: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Neutron Pulse MonitorNPM

Page 4: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Pulse Height Spectrum

Classical 3He spectrum digitized over 128 bins

Page 5: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Plateau Method

Counting Plateau

Lower discriminator

Page 6: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Plateau Method

• Requires many points for good resolution on discriminator set point• For low count rates, time per point may be large

Page 7: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

LowerDiscriminator

UpperDiscriminator

Multichannel Analyzer

Page 8: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 9: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 10: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 11: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 12: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 13: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 14: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 15: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 16: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 17: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 18: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Page 19: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

Valley Peak

Page 20: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Setting the Discriminator Levels

With a Multichannel Analyzer (MCA)

PeakValley

Page 21: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Real Spectra

Page 22: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

0 20 40 60 80 100 120 1400

500

1000

1500

2000

2500BF3 Gas Proportional Tube,

Pulse Height Spectrum

Relative Pulse Height

# of

Cts

"Valley"

Wall-Effect Continuum

Gamma and Electronic Noise Generated Counts

Excited State Peak

Ground State Peak

Real Spectra

Page 23: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

0 20 40 60 80 100 120 1400

500

1000

1500

2000

2500

3000

3500 Boron-Lined GE Reuter-Stokes TubePulse Height Spectrum

Relative Pulse Height

# of

Cts

Lithium-7 Recoil Events Alpha particle Events

Real Spectra

Page 24: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

0 20 40 60 80 100 120 1400

50

100

150

200

250

300

He3 Tube Hgms indicated detecor problem during system QA testing. The manu-facturer reworked the tube.

Hgm # 0, 8/10/2011,04:47

Hgm # 1, 8/10/2011,05:12

Hgm # 2, 8/10/2011,06:12

Hgm # 3, 8/10/2011,07:12

Hgm # 4, 8/10/2011,08:12

Hgm # 5, 8/10/2011,09:12

Hgm # 6, 8/10/2011,10:12

Hgm # 7, 8/10/2011,11:12

Relative Pulse Height

# of

Cts

, Sca

led

He3 tube failure under thermal cycle testing

Page 25: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Example of Field Neutron Detector System Failure, BF3 DetectorTime Series

85 87 89 91 93 95 970

200

400

600

800

1000

1200

Customer Supplied Data, BF3 Detector, Deployed in Remote Field Location, Data Telemetry

via Iridium Satellite

Thermal Neutrons

Day of Year, 2011, UTC

Cts

/ H

r

Page 26: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

0 20 40 60 80 100 120 1400

50

100

150

200

250

300

Customer Supplied Data, BF3 Detector, Remote Location, Data Telemetry via Iridium Satellite,

Hgms from Days 87 and 88 -> System OK!

Day 87Day 88

Relative Pulse Height

# of

Cts

(Sca

led)

Histograms before and after suspicious neutron counts

0 20 40 60 80 100 120 1400

50

100

150

200

250

300

Customer Supplied Data, BF3 Detector, Remote Location, Data Telemetry via Iridium Satellite,

Hgms from Days 91 and 92 -> System Problem!

Day 91

Day 92

Relative Pulse Height

# of

Cts

(Sca

led)

DirtyConnector

Page 27: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

NPM Architecture

Page 28: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Value of a Digital NPM

• Computer interface

• MCA & spectra - optimization

• Monitoring

• Data logging

Page 29: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Data Logger

• Analog & digital I/Os• Relays• USB, RS-232, SDI-12• SD cards• Connect to NPMs• External Sensors• Telemetry

Page 30: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Remote Monitoring & Mobile Detectors

Page 31: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Remote Monitoring & Mobile Detectors

Page 32: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Remote Monitoring & Mobile Detectors

Page 33: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.70

50

100

150

200

250

300

350

400

0

10

20

30

40

50

60

70Univ of Arizona, He3 Roving Instrument, Channel 2 Humidity Intrusion

N1CN2CDeg CInstrument Relative Humidty %

Day of Month (Jul 2013)

Coun

ts p

er 1

min

ute

Inte

rval

Tem

pera

ture

and

RH%

Roving Detector Data

Page 34: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

0 20 40 60 80 100 120 1400

50

100

150

200

250

300Univ of Arizona, He3 Roving Instrument, Channel 2, Humidity Intrusion

Before Humidity Intrusion, System OK

During Humidity Intrusion

After Humidity Intrusion, System Recovered

Relative Pulse Height

Scal

ed #

of C

ount

sRoving Detector Data

Noise produced by humidity

Page 35: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Remote Monitoring & Mobile Detectors

Page 36: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

IAEA: Mobile Unit for Neutron Detection (MUNDs)

Page 37: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

IAEA: MUNDs

NPM

NPM: Ethernet + 15MHz input pulse counter

Page 38: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Soil Moisture Monitoring

Average Soil Moisture

600 meters

Field scale soil moisture monitoring using cosmic ray neutrons

Measures fast and slow neutrons

Pressure & Humidity dependent

Page 39: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Soil Moisture Monitoring

Challenges

• Low power consumption • Very low count rate• High stability in calibration required wide temperature range• High resolution pressure meas

Page 40: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Soil Moisture Monitoring

Page 41: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Soil Moisture Monitoring

Alpine Location

Page 42: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

New Stuff

Page 43: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Neutron Detector Arrays

Page 44: Quaesta Instruments Tucson Arizona Founded in 2008 Staff: 10 Electronic devices: radiation detection environmental monitoring data logging telemetry Off-the-shelf

Neutron Detector Arrays