qualified partner program r&m rj45 connectors felice guarna, training program manager wetzikon,...

57
Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec . 2005

Upload: luke-barker

Post on 11-Jan-2016

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

Qualified Partner Program

R&M RJ45 Connectors

Felice Guarna, Training Program Manager

Wetzikon, Dec . 2005

Page 2: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 2Dec. 2005

R&M Technology: from PCB to leadframe

Printed circuit boardEasy lock

RJ45 jack (OEM)

Direct connection moduleR&Mfreenet

R&M plug and jack

First Generation

Second Generation

Third Generation

Page 3: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 3Dec. 2005

R&M Technology: leadframe and beyondGET MORE @ R&M

RCC45©

Page 4: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 4Dec. 2005

R&M RJ45 evolution, PCB module (1st generation)

Page 5: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 5Dec. 2005

R&M RJ45 evolution, PCB module (1st generation)

NEXT

IBM ACS PCB module:

1 10 100100

90

80

70

60

50

40

30

20

Frequency [MHz]

[dB

]

Page 6: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 6Dec. 2005

R&M RJ45 evolution: DCM (2nd generation)

Plug

Jack

Leadframe in two partsLaser soldered

Page 7: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 7Dec. 2005

R&M RJ45 evolution: Direct Connection Module (2nd generation)

NEXT (Cat 5e performance)

R&Mfreenet DCM shielded:

1 10 100100

90

80

70

60

50

40

30

20

Frequency [MHz]

[dB

]

Page 8: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 8Dec. 2005

R&M RJ45 evolution: Cat. 6 (3rd generation)

Plug

Jack

a.)

b.)

Page 9: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 9Dec. 2005

R&M RJ45 evolution: Cat. 6 (3rd generation)

NEXT of Pairs 3,6 - 5,4

-100.00

-90.00

-80.00

-70.00

-60.00

-50.00

-40.00

-30.00

-20.00

-10.00

0.001.00 10.00 100.00 1000.00

MHz

dB

Cat. 5

TOC 40

Cat. 6

R&M Cat. 6

Page 10: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 10Dec. 2005

Driving forces behind evolutions

Need to short signal travelingIncrease compensation as result of increased frequencyChange of plug NEXT values and method of measuresRedesign plug to achieve a semi-

automated patch cord processImprove contact geometryAchieve interoperability and backward compatibility

Eliminate un-necessary costs by eliminating partsReduce workmanshipKeep all parts and processes within the company

Technical

Economics

Page 11: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 11Dec. 2005

Driving forces behind evolutions

Reduce opportunity for errors: manufacturing and terminating

Produce with automated process both jack and plug, a further step into patch cord automation

Keep performance steady and high both in production and in assembly by designing simple terminations (jack and plug without pair splitting and cross-over)

Eliminate all parts creating variance (PCB and manual soldering)

Quality

Page 12: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 12Dec. 2005

R&M RJ45 connectors

RJ45 theory

R&M positioning for jack and plug

Classic system, Cat. 5e jack

Star system, Cat. 6 jack and plug

Page 13: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 13Dec. 2005

RJ45 theory, connector system

RJ 45 according to IEC 60603-7-X

Jack

(fixed connector)

Plug

(free connector)

Page 14: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 14Dec. 2005

RJ45 theory, pin assignment of pair 2 (3, 6)

Installation cablePatch cord RJ

PlugRJ

Jack

Connector system

1,2

3,6

5,4

7,8

1

2

3

4

5

6

7

8

1,2

3,6

5,4

7,8

Page 15: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 15Dec. 2005

RJ45 theory, crosstalk in a connector system

Inductive coupling

CapacitiveCoupling Ck = C1 + C4 - C2 - C3

3 2 16

Paar 3

Paar 2

C3

C1

C2

C4

Coupling surface

Page 16: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 16Dec. 2005

RJ45 theory, worst case pair combination 3,6 - 5,4

Pair 1

Pair 2

3 4 5 6

Page 17: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 17Dec. 2005

RJ45 theory, transmission property RJ45

1 10 100100

90

80

70

60

50

40

30

20

Frequenz [MHz]

in d

B

NEXT in an uncompensated plug - jack combination:

Cat 5eLimit

3,6/4,5

Page 18: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 18Dec. 2005

RJ45 theory, how does a compensation work?

Balanced transmission:

+

-

Pair 1

-

+

1 wavelength

Pair 2

Com

pens

atio

n

Cross

talk

a

bNEXT plug

NEXT jack

Compensation

= 0

Page 19: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 19Dec. 2005

RJ45 theory, function zones in a connector system

Plug : Jack: Compensation: Connection technique:

For example:Printed circuit

board

IDCblock

Page 20: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 20Dec. 2005

RJ45 theory, key factors in compensation

The main characteristics of a zone are the following:

Size of compensation: XS, XB, XK [dB] @ phase position ( + / - )

Length of contact span: LS, LB, LK [mm]

Velocity of propagation: z

LS LB LK

XS XB XK

Page 21: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 21Dec. 2005

RJ45 theory, effect of the distributed components

Distributing the crosstalk over the length of the tracks and the place of origin.

= = =

Page 22: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 22Dec. 2005

RJ45 theory, effect of phase shift

Phase shift of the signal as a result of propagation time along the contacts.

Signal:

Result

Low frequencies

High frequencies

A B C

Page 23: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 23Dec. 2005

RJ45 theory, limits of compensation

NEXT plug

NEXT jack

Compensated signal

Compensation

Amplitude variations:

20 dB / decade slope

=

Module = -35.5 dB Kompensation

-100

-80

-60

-40

-20

0

1 10 100 1000

MHz

dB

-32 dB Stecker

-34 dB Stecker

-36 dB Stecker

-38 dB Stecker

Compensation

PlugPlugPlugPlug

Page 24: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 24Dec. 2005

RJ45 theory, limits of compensation

NEXT plug

NEXT jack

Compensated signal

Compensation

Phase shift due to connector length:

Module = -37 dB Kompensation

-100

-80

-60

-40

-20

0

1 10 100 1000

MHz

dB

70 mm Modul

45 mm Modul

30 mm Modul

15 mm Modul

40 dB / decade rise

Compensation

Page 25: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 25Dec. 2005

RJ45 theory, simulation of a Cat. 5 print module

Plug Connector Jack Compensation

Length [mm] = 20 30 10Total X-Talk [dB] = -34 -34 -28.7 @ 100 MHzNVP = 0.8 0.8 0.8

ResultsFrequency [MHz] = 100 NEXT [dB] = -42.9

Phase Shift [°] = 13.5

Page 26: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 26Dec. 2005

RJ45 theory, example print module

Simulation Printmodul

-100

-80

-60

-40

-20

0

1 10 100 1000

MHz

dB

Simulation

Einfluss Länge

Einfl. Amplitude

Messung

Effect of length

Effect of amplit.

Test result

PCB Modul

Page 27: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 27Dec. 2005

De-embedded NEXT testing of the plug (1)

1)Measuring reference plug terminated on protruding pairs

2) Cutting off protruding ends

3) Measuring reference jack with reference plug

4) Calculating influence of reference jack jack = total - plug

Reference plug

Total

Reference plug

Reference jack

Total

Page 28: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 28Dec. 2005

De-embedded NEXT testing of the plug (2)

5) Measuring test object (plug) with reference jack

6) Calculating test object (plug)plug = total - jack

Total with test object

Test object

Reference jack

Total with test object

Page 29: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 29Dec. 2005

Interoperability between vendors

Plug 1Module 1

Cat. 6

Manufacturer 1

Plug 3Module 3

Cat. 6

Manufacturer 3

Plug 2Module 2

Cat. 6

Manufacturer 2

Plug 2Module 3

Cat. 6

Mix and Match

Page 30: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 30Dec. 2005

Backwards compatibility

Cat. 5 plugCat. 5e module

Cat. 6 plugCat. 6 module

Cat 5e

Cat. 6

Cat. 6 plugCat. 5e module

Cat 5e

Cat. 5 plugCat. 6 module

Cat. 5e

Page 31: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 31Dec. 2005

Standardization Cat. 6 - basics

Verhalten Stecker - Modul@ 100 MHz

30

40

50

60

33 34 35 36 37 38 39

Stecke NEXT

Mo

du

le N

EX

T

Cat. 5

Cat. 5e

Cat. 6

Plug – Module Behavior

Plug

Page 32: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 32Dec. 2005

How do we characterize R&M jacks

Innovations: Unique shielding contact (patented) Absolutely tool-less Internal mechanically designed compensation Backward compatibility and full interoperability Special contact shape (Cat. 6 only) Front End

Innovative manufacturing process assuring: cost effectiveness less parts consistent electrical performance QUALITY

Back end

Technology

Know How

Page 33: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 33Dec. 2005

360 degree EMC protection

Earthing bridge allows free choice of ground bonding topology

Bonding by large-area (reed contact world-wide patent)

Ensures the required contact pressure for an outstanding EMC performance (high frequency also)

Ensures quick and reliable ground bonding

Ensures clean cable tension relief

Comparative tests show the superiority of shield reed contacting over conventional "clip-on" contacting

PLUS SUPERIOR PERFORMANCE

R&M jacks (EMC) features

Page 34: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 34Dec. 2005

Tool-free "Easy Lock" connection technique (IDC)

Wiring label for error-free termination (both 568 A and B type)

Conductors wired without pair crossover

SUPERIOR PERFORMANCE

Flexibility

Ri-terminatable

Used in any places (panel, outlet, MUTO, CP)

Can accept larger conductors using special easylock

Can be used in different applications: IBM GFP, keystone and special adapters

Cat. 5 and Cat. 6 modules are mechanically interchangeable

Limited dimension/easy interface allow usage in wide range of existing outlets

R&M jacks features

Page 35: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 35Dec. 2005

Easy Lock and patented screen contact makes R&M jack the quickest screened

Rj45 jack to terminate. Absolutely no tools is required and a maximum reliability

is guaranteed.

The parallel pair wiring ensures optimum twisting up to the connecting point, this

is reflected in the excellent transmission values.

Thanks to its minimum installation depth, the module can be easily installed in

the largest range of outlets or patch panels world-wide.

The R&M patented shielding contact assure fool proofs bonding and reliable

screening

THE QUICKEST AND SAFEST SHIELD TERMINATION

R&M jacks advantages

Page 36: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 36Dec. 2005

R&M jacks compliances

Conform to Cat. 5e requirements for connection components according to ISO/IEC 11801 and EN 50173

Conform to EMC requirements according to EN 55022/class B (interference radiation)

UL and CSA certified

Data cables with AWG 24-22 conductor diameter

Comply with reliability testing according to ISO/IEC 11801 and EN 50173

Page 37: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 37Dec. 2005

CLASSICsystem, Cat. 5e jack

The RJ45 jack complies with the requirements of Class De, E (125/250 MHz)

The jack complies with the requirements of Cat. 5e (125MHz)

It is the only RJ45 module to have been certified in a channel for 250 MHz and 750 MHz by an independent test laboratory (3P).

The best module worldwide for Ethernet applications in its category

Page 38: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 38Dec. 2005

STARsystem, Cat. 6 jack

Characteristics

True Cat. 6 performance (Independent certified by 3P)

Backward compatible to Cat. 5e

Traceability through integrated serial number

Integrated coding scheme

Each module tested for NEXT and RL

Page 39: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 39Dec. 2005

STARsystem Cat. 6 jack, the new product

Page 40: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 40Dec. 2005

Special spring bronze with Ni plating for enhanced performance and durability

Contacts in one piece

Gold plating in the contact area

Sn plating in the IDC area

Patent pending contact design

Flexible contacts to fit even RJ11

Contact design to minimise the distance between plug and compensation

Compensation in very small size with trimming capability

Capacitive and inductive coupling

STARsystem Cat. 6 jack, Cat. 6 the product inside

Page 41: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 41Dec. 2005

STARsystem Cat. 6 jack, Cat. 6 features

Meets the requirements for Cat. 6 connecting hardware standard according to

latest draft release (Industry agreed)

Easy and tool-less termination of all cable types (solid/stranded)

Pairs stay together up to termination point

Fits in all R&Mfreenet racks and outlets produced so far

Special colour to differentiate from Cat. 5e

Consistent electrical performance achieved through a fully automated assembly line

Page 42: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 42Dec. 2005

Mechanical:

Nominal conductor diameter: 0.5-0.65 solid; AWG 24-26 stranded

Nominal insulation diameter: 0.8-1.6 mm

Number of conductors: 1-8

Holding of conductors: IDC block (patent EP671780 B1)

Colouring scheme: type A or B possible (type A preferred)

Screen Contact: tongue (patent EP671787)

Screen: 360 degree shielding

Conductor termination cycles: 20

Plug interface cycles: > 750

STARsystem Cat. 6 jack, mechanical characteristic

Page 43: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 43Dec. 2005

Dämpfung

-0.50

-0.40

-0.30

-0.20

-0.10

0.00

1.00 10.00 100.00 1000.00

MHz

dB

5,4

3,6

1,2

7,8

Limite

STARsystem Cat. 6 , jack insertion loss

Page 44: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 44Dec. 2005

Return Loss

-100.00-90.00

-80.00-70.00

-60.00-50.00

-40.00-30.00

-20.00-10.00

0.00

1.00 10.00 100.00 1000.00

MHz

dB

5,4

3,6

1,2

7,8

Limit

STARsystem Cat. 6 jack, return loss

Page 45: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 45Dec. 2005

STARsystem Cat. 6 jack, NEXT

NEXT with a Cat. 6 plug and a Cat. 6 jack

20.00

30.00

40.00

50.00

60.00

70.00

80.00

90.00

100.00

110.00

120.00

1.00 10.00 100.00 1000.00

Frequency [MHz]

[dB

]

3,6 - 5,4

1,2 - 5,4

5,4 - 7,8

1,2 - 3,6

3,6 - 7,8

1,2 - 7,8

Cat. 6

Page 46: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 46Dec. 2005

NEXT of pairs 3,6 - 5,4

-100.00

-90.00

-80.00

-70.00

-60.00

-50.00

-40.00

-30.00

-20.00

-10.00

0.00

1.00 10.00 100.00 1000.00

MHz

dB

Cat. 5

TOC 40

Cat. 6

R&M Cat. 6

Cat. 6 and Cat. 5 jack, next comparison

Page 47: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 47Dec. 2005

Results of the de-embedded testing by R&M

Conclusions:

Best performer: R&M UTP and STP. The best balance between margin and standard deviation results in the best margin.

Best margin: R&M UTP combined with the second best standard deviation which guarantees the best lowest margin and therefore the first place

The R&M STP jack conquered the first place with the second best margin combined with the second best standard deviation which guarantees the best margin

Page 48: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 48Dec. 2005

STARsystem Cat. 6 jack, Cat. 5e backward compatibility

NEXT with a Cat. 5/5e plug and a Cat. 6 jack (Backward compatibility)

0.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

90.00

100.00

1.00 10.00 100.00 1000.00

Frequency [MHz]

dB

3,6 - 5,4

1,2 - 5,4

5,4 - 7,8

1,2 - 3,6

3,6 - 7,8

1,2 - 7,8

Cat. 5e

Page 49: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 49Dec. 2005

Cat. 6 module difference:

Test method is described in IEC 603-7-4 and -5

The connecting hardware is measured with the plug (mated)

Specific test plug are needed

Advantages:

Interoperability between products (plug)

Full compatible to standard

Backward compatibility is guaranteed

Cat. 6 hardware: differences from Cat. 5

Page 50: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 50Dec. 2005

Interoperability:

A Cat. 6 module mated with different (vendors) Cat. 6 plugs, as defined by the

standard, must produce NEXT and FEXT values above the limits for Cat. 6

Backwards compatibility:

A Cat. 6 module mated with Cat. 5 plugs, as defined by the standard, must

produce NEXT and FEXT values above the limits for Cat. 5e

De-embedded NEXT of a plug

The de-embedded NEXT procedure is a method to determine the crosstalk

which is produced inside a plug only. The standard defines ranges of allowed

crosstalk for each pair combination and category

Cat. 6 hardware: peculiarities

Page 51: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 51Dec. 2005

EN 50173 second edition:

Chapter 8 connecting hardware requirement mechanical and electrical according to IEC 60603-7-4

ISO/IEC 11801 second Edition:

Chapter x connecting hardware requirement mechanical and electrical according to IEC 60603-7-4 and 7-5

EIA/TIA 568B

Cat. 6: reference standards

Page 52: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 52Dec. 2005

R&Mfreenet Cat 6 JackGET MORE @ R&M

Several Competitors have now Independent Labs tested Jack

Is there any difference between R&M and Competition ?

Independent Labs at the moment test only prototypes not production

Prototypes may not be real representation of current production

Prototypes to be tested by Lab can come from best production batches

Production variance depends on manufacturing process control

MANUFACTURING PROCESS CONTROL

Page 53: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 53Dec. 2005

Technology, application, design, material to support better performance

Process Control More than 2000 parameters

Final test

100% of production

NEXT and RL

GET MORE @ R&M

Page 54: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 54Dec. 2005

Thanks to special terminal based on IDC technique, the R&M plug is one of the

few available on the market allowing crimping on both solid and stranded wires

with increased contact reliability

The R&M plug is suitable for semi-automated patch cord production

The R&M plug is only terminated and tested in factory

Positioning plug: flexibility

Page 55: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 55Dec. 2005

IDC contacts to connect stranded and

solid wires Improved reliability compared to

piercing contacts (contact resistance)

Stranded: 0.09-0.22 mm2 Solid: < 0.5 mm Contact zone always at the same

levelParallel mounting of the wire pairs ontwo layers

Crossing 3/6-4/5 is done in front by contacts (patent pending)

Well defined crosstalk Superior process control

STARsystem Cat. 6 plug

Page 56: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 56Dec. 2005

STARsystem Cat. 6 plug

Housing of tin plated brass

Standard outer dimensions

New strain relieve

Cables are fixed 360 degree

Pairs stay at the same place

Better performance

For screened cables additionally

Screen contact 360 degree

Lifetime screen contact

Common typePlug outer dimension

R&M type

Page 57: Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

R&M RJ45 Connectors / Page 57Dec. 2005

The first connecting hardware which meets the relevant Cat. 6 hardware requirement

Independent lab certified: 3P, Delta, GHMT

First Cat. 6 module without PCB

As easy as Cat. 5 to terminate

Same connecting hardware at distributor and outlet side

Next and RL tested 100% in production

STARsystem Cat. 6 jack an plug, summary