Quality management, calibration, testing and comparison of instruments and observing
systems
M. Leroy,
CIMO ET on SBII&CM
![Page 2: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/2.jpg)
Quality management, some aspects
Explicit identification of uncertainty objectives Representativeness of observations Calibration and maintenance Selecting instruments : knowing their characteristics
– Testing– Intercomparisons
Composite observing systems Value analysis ISO 9001-2000 is an international frame
![Page 3: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/3.jpg)
Quality management process
Setting and documenting objectives Defining associated indicators Regular survey of indicators Regular survey of users’ (customers) needs and
satisfaction. Correcting and improving
![Page 4: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/4.jpg)
Identification of uncertainty objectives
Identification of users of observation data– Forecasters and climatologists– Few direct users of observation : special case is aeronautic
users, with needs clearly defined in Annex 3 of ICAO.
Getting the users’ needs is not always easy– They are not always aware of the possible uncertainty and
associated cost. – A value analysis is necessary to get a good compromise.
The CIMO guide (WMO doc n° 8) is a guide.– Annex 1B indicates users’ needs and achievable measurements
(best state of the art).
The measurement uncertainty must be demonstrated. So realistic choices must be done.
![Page 5: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/5.jpg)
An example
For his proprietary Radome network, mainly dedicated for real-time observation, Météo-France has set up the following objectives; some are less ambitious than the achievable measurement uncertainty stated by the CIMO guide.– 0.5 hPa for pressure– 6% for relative humidity– 0.5°C for air temperature– 10% for wind speed– 5-10% for precipitation amount– 5% for daily amount of solar radiation.
![Page 6: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/6.jpg)
For other objectives, additional care can be necessary
Example : US Climate Reference Network – Redundancy and cross check of measurements.– 3 independent air temperature measurements.– Dual fence rain gauge.– Associated measurement of wind speed.
Such efforts cannot be made in each station of a climatological cooperative network.
![Page 7: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/7.jpg)
Quality indicators
Availability of data in the (final) data base– Within a given limit of time : example 95% of expected surface
observations available within 10 minutes.– Availability of data in the climatological data base : example 98%
for the Radome network. Measurement uncertainty
– % of sensors calibrated in a stated delay : example 12 months nominal, 15 months maximum, objective is more than 90%.
– % of sensors found outside an Acceptable User Limit : example hygrometers found with one (or more) control point more than 5% from the reference. These sensors are flagged as having drifted.
– % of sensors for which the periodicity of preventive maintenance is respected.
– % of large errors when compared to numerical models (monitoring)
![Page 8: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/8.jpg)
Some examples
![Page 9: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/9.jpg)
![Page 10: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/10.jpg)
![Page 11: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/11.jpg)
![Page 12: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/12.jpg)
![Page 13: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/13.jpg)
![Page 14: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/14.jpg)
Knowing the characteristics of an instrument
Technological survey : reading publications, participating to conference and instrument exhibitions.
Testing of instruments : please, publish results and make them available.
Intercomparisons, WMO intercomparisons. Read the manufacturers’ technical
documentation, having in mind the common characteristics of instruments, for example, thru the CIMO guide.
![Page 15: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/15.jpg)
Recent WMO intercomparisons
Radiosonde intercomparisons WMO Laboratory Intercomparison of Rainfall
Intensity gauges WMO Field Intercomparison of RI gauges : May
2007-May 2008, Vigna di Valle, Italy WMO Intercomparison of Thermometer
Screens/Shields in conjunction with Humidity Measurements : 2007, Ghardaïa, Algeria
![Page 16: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/16.jpg)
![Page 17: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/17.jpg)
WMO Field Intercomparison of Rainfall Intensity Instruments
The laboratory Intercomparison was a first step, easier to handle than a field test.
Not all instrument types available on the market were tested in laboratory.
Looking for a possible site, Vigna di Valle, Italy (Italian Meteorological Service, ReSMA) was selected.
August 2007 August 2008
![Page 18: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/18.jpg)
![Page 19: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/19.jpg)
![Page 20: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/20.jpg)
Field Intercomparison
Call for instruments (March 2006) 24 instruments of different measuring principles were selected (54
proposed !). Reference based on a set of high quality devices, inserted in a pit
gauge. Draft Rec. 4.2/2 : Procedure and reference instruments for field
rainfall intensity intercomparisons
![Page 21: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/21.jpg)
WMO Combined Intercomparison of Thermometer Screens/Shields, in conjunction with Humidity Measuring Instruments
Looking for a possible site in harsh conditions, Ghardaïa, Algeria was selected.
Desert region Jan. 2007 Jan. 2008 Instruments’ calibration before and after
![Page 22: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/22.jpg)
![Page 23: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/23.jpg)
Screens & Hygrometers Intercomparison
Call for instruments (March 2006) 16 screens/shields’ types (29 proposed) and 11 hygrometers’
types(17 proposed) were selected. Reference : Thygan Data analysis :
– International Organizing Committee
– ISO standard 17714 (draft)
![Page 24: Quality management, calibration, testing and comparison of instruments and observing systems M. Leroy, CIMO ET on SBII&CM](https://reader035.vdocuments.net/reader035/viewer/2022081603/5697bf791a28abf838c823ef/html5/thumbnails/24.jpg)
Conclusion
There are many other subjects and actions concerning quality measurement :– Quality control directly at the level of the measurement systems.– Quality control using spatial and temporal cross-check.– Representativeness of observations, due to the nearby
environment of the measuring site.– …
Quality management and ISO 9001-2000 certification force us to explicit the objectives of observing networks and the proofs demonstrating their achievement.