quantum data, inc. 2111 big timber road elgin, il 60123 usa phone (847) 888-0450 fax (847) 888-2802 ...

15
c. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www. quantum data for Handshake Tester HT-180

Upload: alisha-mayfield

Post on 31-Mar-2015

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

for

Handshake Tester

HT-180

Page 2: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Current Status Built on the technology of our 882 HDCP compliance test feature – the worlds first and only commercially available HDCP Compliance Testapplication.

Built on the technology of our 882 HDCP compliance test feature – the worlds first and only commercially available HDCP Compliance Testapplication.

Enhanced localization features anticipated-- LCD display with error code reporting-- Save “Trace” Files

Enhanced localization features anticipated-- LCD display with error code reporting-- Save “Trace” Files

Provides both up-steam and down-stream views of HDMI component interactions.

Provides both up-steam and down-stream views of HDMI component interactions.

Troubleshoots HDCP, HPD and EDID interoperability problems and helps identify problems.

Troubleshoots HDCP, HPD and EDID interoperability problems and helps identify problems.

Page 3: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – What does it do? Assists in the troubleshooting of HDMI

Interoperability and handshake problems

Assists in the troubleshooting of HDMI Interoperability and handshake problems

Localizes HDCP handshake problems

Identifies EDID problems

Identifies 5V, Current and Hot Plug Issues

Page 4: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Typical root causes

Hot Plug Failures -Checks hot plug for < 100ms deassertion -Verifies that hot plug downstream assertion is passed to upstream -Checks if hot plug detection assertion upstream was not the result of downstream problem -Measures +5v signals for voltage and current draw on a source

Hot Plug Failures -Checks hot plug for < 100ms deassertion -Verifies that hot plug downstream assertion is passed to upstream -Checks if hot plug detection assertion upstream was not the result of downstream problem -Measures +5v signals for voltage and current draw on a source

EDID Failures-Checks if EDID port was not acknowledged -Checks if EDID port access was attempted by source -Verifies that EDID header and checksums are valid-Checks if EDID read was triggered by hot plug detection

EDID Failures-Checks if EDID port was not acknowledged -Checks if EDID port access was attempted by source -Verifies that EDID header and checksums are valid-Checks if EDID read was triggered by hot plug detection

HDCP Failures -Checks for invalid Aksv from source -Verifies that source write of An occurs prior to write of Aksv -Verifies that source read of Bcaps occurs prior to read of R0’ -Verifies that source write of Aksv occurs prior to read of R0’ -Checks for invalid Bksv from sink -Checks if Ri’ is read without second phase of authentication (in case of repeater) -Checks if HDCP reauthentication was triggered by hot plug detection -Checks if HDCP port is not acknowledged -Checks for excessive HDCP re-authentication attempts by source -Verifies that source attempted to access sink HDCP port -Checks if the READY bit is not set as a result of any of the following failure conditions:

Repeater did not attempt to read Bksv downstream receiverSource did not begin reauthentication after five secondsInvalid Bksv

HDCP Failures -Checks for invalid Aksv from source -Verifies that source write of An occurs prior to write of Aksv -Verifies that source read of Bcaps occurs prior to read of R0’ -Verifies that source write of Aksv occurs prior to read of R0’ -Checks for invalid Bksv from sink -Checks if Ri’ is read without second phase of authentication (in case of repeater) -Checks if HDCP reauthentication was triggered by hot plug detection -Checks if HDCP port is not acknowledged -Checks for excessive HDCP re-authentication attempts by source -Verifies that source attempted to access sink HDCP port -Checks if the READY bit is not set as a result of any of the following failure conditions:

Repeater did not attempt to read Bksv downstream receiverSource did not begin reauthentication after five secondsInvalid Bksv

Page 5: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Operation

HT-180 is inserted in an HDMI system. The product will test up toThree different devices for interoperability problems by displaying

Error codes on the LCD as well as in HTML trace files.

HT-180 is inserted in an HDMI system. The product will test up toThree different devices for interoperability problems by displaying

Error codes on the LCD as well as in HTML trace files.

eschieler
add depiction of a geneator connected to a monitor
Page 6: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Operation

Immediate evaluation ondisplayed on the LCD

Immediate evaluation ondisplayed on the LCD

Set up a trace using the trace file capture softwareRunning on a connected PC

Set up a trace using the trace file capture softwareRunning on a connected PC

eschieler
add depiction of a geneator connected to a monitor
Page 7: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Operation

Captured trace files allow system information to be sent to a lab foranalysis. Each trace can specifically identify the components of the

system tested, date and location.

Captured trace files allow system information to be sent to a lab foranalysis. Each trace can specifically identify the components of the

system tested, date and location.

Ticket No.

Customer Info

System

Products!!

eschieler
add depiction of a geneator connected to a monitor
Page 8: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Enhanced failure indication (DDC Protocol Traces)

Reason & action codes-Digests DDC protocol data-Provides root cause code-Documentation provides corrective action

Reason & action codes-Digests DDC protocol data-Provides root cause code-Documentation provides corrective action

DDC protocol traces-USB captures DDC data-Customer service call card with documentation associates activity with DDC trace files

DDC protocol traces-USB captures DDC data-Customer service call card with documentation associates activity with DDC trace files

eschieler
add depiction of a geneator connected to a monitor
Page 9: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Enhanced failure indication (reason & action codes)

Error Codes are shown on the LCD, indicating more precise failure mode and referring to a list of causes as well as possible solutions.Additionally, an “A”, “B” or “C” rating can suggest Severity of the diagnosis.

Error Codes are shown on the LCD, indicating more precise failure mode and referring to a list of causes as well as possible solutions.Additionally, an “A”, “B” or “C” rating can suggest Severity of the diagnosis.

eschieler
add depiction of a geneator connected to a monitor
Page 10: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 – Support

Consultation (if necessary)DDC trace analysis

Consultation (if necessary)DDC trace analysis

DocumentationHT-180 Error Code Reference Guide

DocumentationHT-180 Error Code Reference Guide

eschieler
add depiction of a geneator connected to a monitor
Page 11: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

Current Reason Code ListingsNO_ERROR 0x00,

EDID_HEADER_BAD 0x01,

EDID_CHECKSUM_BAD 0x02,

EDID_NOT_READ 0x03,

EDID_READ_INCOMPLETE 0x04,

EDID_READ_DURING_HPD_LOW 0x05,

EDID_READ_NACKED_HPD_HI 0x06,

LARGE_EDID_WITHOUT_EDDC 0x07,

EDID_NOT_READ_AFTER_HPD 0x08,

EDID_CROSSED_256_BYTES 0x09,

AKSV_BAD 0x10,

BKSV_BAD 0x11,

FACSIMILE_AKSV 0x12,

FACSIMILE_BKSV 0x13,

HDCP_NOT_ATTEMPTED 0x14,

HDCP_READ_DURING_HPD_LOW 0x15,

HDCP_NACKED_HPD_HI 0x16,

AKSV_WRITTEN_BEFORE_AN 0x17,

Page 12: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

Current Reason Code ListingsAKSV_WRITTEN_WRONG_ORDER 0x18,

AKSV_SENT_MULT_TIMES 0x19,

HDCP_WENT_BEYOND_LENGTH 0x1A,

KSV_FIFO_READ_INCOMPLETE 0x20,

KSV_FIFO_READ_NOT_5_MULT 0x21,

KSV_FIFO_HAD_BAD_KSV 0x22,

KSV_FIFO_HAD_FACSIM_BKSV 0x23,

KSV_FIFO_WITHOUT_BSTATUS 0x24,

KSV_FIFO_READ_TOO_LONG 0x25,

KSV_FIFO_MISSING_BKSV 0x26,

KSV_FIFO_WITH_NO_DEVS 0x27,

KSV_FIFO_WITH_NO_READY 0x28,

R0_READ_WITHIN_100MS 0x30,

R0_READ_BEFORE_BCAPS 0x31,

R0_READ_WITHOUT_AKSV 0x32,

R0_READ_BEFORE_BKSV 0x33,

RI_MISMATCH_CAUSE_REAUTH 0x34,

R0_MISMATCH_CAUSE_REAUTH 0x35,

Page 13: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

Current Reason Code ListingsSOURCE_USES_SHORT_READS 0x36,

BCAPS_RESERVED_BITS_SET 0x40,

BCAPS_NOT_READY_IN_TIME 0x41,

NO_REAUTH_AFTER_NO_READY 0x42,

DS_FAIL_WITH_NO_HPD 0x43,

BCAPS_NOT_POLLED 0x44,

BCAPS_READY_CAUSE_REAUTH 0x45,

BSTATUS_HAD_MAX_DEVS_EX 0x50,

BSTATUS_HAD_MAX_CASC_EX 0x51,

BSTATUS_RESERVED_SET 0x52,

BSTATUS_NOT_HDMI_MODE 0x53,

BSTATUS_HDMI_NO_BCAPS 0x54,

BSTATUS_DEVS_0_WITH_DEV 0x55,

BSTATUS_DEV_CNT_0_PROB 0x56,

BSTATUS_MAX_STAT_NO_PASS 0x57,

AINFO_1_1_SET_NO_BCAPS 0x60,

AINFO_RESERVED_SET 0x61,

AINFO_AFTER_AKSV 0x62,

Page 14: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

Current Reason Code ListingsV_PRIME_WITH_NO_BSTATUS 0x64,

V_PRIME_WITH_NO_READY 0x65,

DOWNSTREAM_AUTH_NOT_UP 0x67,

DOWNSTREAM_REAUTH_NOT_UP 0x68,

REAUTH_CONSTANT 0x69,

SOURCE_STOPS_POLLING_RI 0x6A,

DDC_MISSING_STOPS 0x6C,

DDC_MISSING_STARTS 0x6D,

HPD_TOO_SHORT 0x70,

HPD_NEVER_GOES_HIGH 0x71,

HPD_NOT_PASSED_THROUGH 0x72,

HPD_NOT_HIGH_AFTER_5_SEC 0x73,

NO_REAUTH_AFTER_HPD 0x74,

AUTH_CONTINUES_AFTER_HPD 0x75,

VOLTAGE_TOO_LOW 0x78,

VOLTAGE_TOO_HIGH 0x79,

CURRENT_PULL_TOO_HIGH 0x7A

Page 15: Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802  quantum data for Handshake Tester

Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com

quantum data

HT-180 Diagnosis & Study

The HT-180 will provide aconvenient method for identifying

interoperability problems inthe field and help service

providers develop strategiesfor solving customer

digital HD installation problems.

The HT-180 will provide aconvenient method for identifying

interoperability problems inthe field and help service

providers develop strategiesfor solving customer

digital HD installation problems.