quick guide newclassic balances ms-s / ms-l models · unit 2 >> 8. g ¦ mg. no key beep...
TRANSCRIPT
C
1
2
3
4
75 6 9 810
• Cancel running application
NET
WEIGHING
0.00 g
0.00 g
121.01 g
0.00 g Net
22.00 g Unit 1,
* 22.00 g M Recall,
0.78 oz Unit 2
Execute the assigned F1 application. Factory setting: "Piece Counting"
Execute the assigned F2 application. Factory setting: "Percent Weighing"
Execute the assigned F3 application. Factory setting: "Checkweighing"
F1
F2
F3
Activate weighing application
• if activated• if different
from Unit 1
• if activated
#
,
C
C
M
NewClassic BalancesMS-S / MS-L Models
Qui
ck G
uide
Easy Weighing Access Quick Application Access Direct Adjustment Access
External Adjustment Procedure
Switching Units
Application Settings
Operation Keys Display Panel
Tare
Press and hold
Press briefly
Press briefly
Press and hold
Press and hold
Press and hold
Note:There is a timeout during the setup. The balance switches back to the last active application.
Press briefly
Press briefly
Execute predefined adjusting (calibration) procedureFactory Setting: Internal adjustment(MSxxxE models: external adjustment)
COUNTING
FIX 10 PCS
PERCENT
SET 100 %
CHECK
SET NOM.
Wei
ght V
alue
Fie
ld
Application Icons Status Icons
Unit
Fiel
d
Status IconsWeighing-in aid
Application Icons
Menu locked
Menu settings activated
Application “Weighing”
Application “Piece counting”
Application “Percent weighing”
Application “Check weighing”
Application “Statistics”
Application “Formulation / Net-Total”
Application “Totaling”
Application “Dynamic weighing”
Application “Multiplication factor”
Application “Division factor”
Application “Density”
Status Icons
Indicates stored values (memory)
Indicates Net weight values
Adjustments (calibration) started
FACT activated
Diagnostic mode & Application “Routine test” activated
Service reminder
Acoustic feedback for pressed keys activated
Weighing range 1 (Dual Range models only)
Weighing range 2 (Dual Range models only)
Charge of battery; full, 2/3, 1/3, discharged (Battery operated models only)
Unit Field
Marking of weighing units:g gramkg kilogrammg milligramct caratlb poundoz ounceozt troy ounceGN graindwt pennyweightmom mommemsg mesghaltlh Hong Kong taelstls Singapore taelstlt Taiwan taelstola tolabaht baht
>> Selection available
Weighing-in aid
Marking of nominal or target weight
Marking of tolerance limit T+
Marking of tolerance limit T-
Weight Value Field
Indicates negative values
Indicates unstable values
Indicates calculated values
Indicates uncertified digits (approved models only)
Key Functions
No. Key Press briefly (less than 1.5 s) Press and hold (longer than 1.5 s)
1
• To change display resolution (1/10d function) while application is running Note: not available with approved models in selected countries
no function
2
• Enter or leave menu (Parameter settings) no function
3
• Execute predefined adjusting (calibration) procedure
no function
4
• Printout display value• Printout menu settings• Transmit data
no function
5
• To navigate back (scroll up) within menu topics or menu selections
• Decrease (numerical) parameters within menu and in applications
• To select the weighing application• Decrease (numerical) parameters quickly
within menu and in applications
6
• To navigate forward (scroll down) within menu topics or menu selections
• Increase (numerical) parameters within menu and in applications
• To select assigned F1 application and enter-ing the parameter settings of application.
• Default F1 application assignment: Piece counting
• Increase (numerical) parameters quickly within menu and in applications
7
• With entries: scroll down• To navigate through menu topics or menu
selections• To toggle between unit 1, recall value (if
selected), unit 2 (if different from unit 1) and the application unit (if any)
• To select assigned F2 application and enter-ing the parameter settings of application.
• Default F2 application assignment: Percent weighing
8
• To enter or leave menu selection (from / to menu topic)
• To enter application parameter or switch to next parameter
• To store parameter
• To select assigned F3 application and enter-ing the parameter settings of application.
• Default F3 application assignment: Check-weighing
9 ON/OFF#
• Switch on• Zero/Tare
• Switch off
10 C • Cancel and to leave menu without saving (one step back in the menu). • no function
Net
ADJ.EXT
1000.00 g
------
0.00 g
------
ADJ DONE
0.00 g
Mettler-Toledo AGLaboratory WeighingCH-8606 Greifensee, Switzerland
Subject to technical changes© Mettler-Toledo AG 01/2014 11781215F en
www.mt.com/newclassic
*11781215*
Topic SelectionDATE.FORM>> 8 DD.MM.Y
MM/DD/Y
Y-MM-DD
D.MMM Y
MMM D Y
TIME.FORM>> 8 24:MM
12:MM
24.MM
12.MM
RECALL >> 8 OFF
ON
SHUTOFF >> 8 A.OFF10 min
A.OFF -
A.OFF 2 min
A.OFF 5 min
BCKLIGHT >> 8 B.L. ON
B.L. 30 s
B.L. 1 min
B.L. 2 min
B.L. 5 min
DISPLAY >> 8 BRIGHTN. >> 8 50 %
CONTRAST>> 8 75 %
AUTOZERO>> 8 ON
OFF
ZERO RNG>> 8 21.00 g
LANGUAGE>> 8 ENGLISH
DEUTSCH
FRANCAIS
ESPANOL
ITALIANO
RUSSIAN
POLSKI
CESKY
MAGYAR
NEDERL.
BR.PORTUG.
ASSIGN:F1>> 8 COUNTING
PERCENT
CHECK
STAT
FORMULA
TOTALING
DYNAMIC
FACTOR M
FACTOR D
DENSITY
ASSIGN:F2>> 8 PERCENT
CHECK
¦ ¦COUNTING
ASSIGN:F3>> 8 CHECK
¦ ¦R.TEST
COUNTING
PERCENT
DIAGNOSE>> 8 REPEAT.T
DISPLAY
KEYPAD T
CAL.MOT. T
BAL.HIST
CAL.HIST
BAL.INFO
PROVIDER
SERV.ICON>> 8 ON
OFF
SRV.D.RST>> 8 NO?
YES?
BASIC >> 8
ADVANCED>> 8
INT.FACE >> 8
PROTECT >> 8
,
+8
C
Basic Menu
Advanced Menu
Interface Menu
Protection
• Enter menu• Leave menu
with saving
Scroll down
Menu Map
Scroll up
• Enter selection or menu
• Execute setting
• One step back• Leave menu
without saving
Menu Operation
Main Menu
Basic Menu
Advanced Menu
Topic Selection
DATE >> 8 01.01.2008
TIME >> 8 +1H
-1H
SET TIME>> 8 12:00
UNIT 1 >> 8 g
¦kg
UNIT 2 >> 8 g ¦
mg
NO
KEY BEEP >> 8 MED
HIGH
OFF
LOW
STAB.BEEP>> 8 LOW
MED
HIGH
OFF
RESET >> 8 NO?
YES?
Topic Selection
WEIG.MODE>> 8 UNIVERS.
DOSING
ENVIRON.>> 8 STANDARD
UNSTABLE
STABLE
CAL >> 8 ADJ.INT
ADJ.EXT >> 8 200.00 g
ADJ.OFF
ADJ.CUST.F>> 8 EXECUTE
RESET >> 8 NO?
YES?
FACT >> 8 TIME >> 8 12:00
OFF
FACT PRT>> 8 ON
OFF
Interface MenuTopic Selection
RS232 >> 8 PRINTER >> 8 PRT.STAB
PRT.AUTO
PRT.ALL
PC-DIR. >>. 8 PRT.STAB
PRT.AUTO
PRT.ALL
HOST >> 8 SEND.OFF
SEND.STB
SEND.CONT
SEND.AUTO
SEND.ALL
2.DISPLAY ¥
HEADER >> 8 NO
DAT/TIM
D/T/BAL
SINGLE >> 8 NET
G/T/N
SIGN.L >> 8 OFF
ON
LINE.FEED >> 8 0
ZERO PRT.>> 8 OFF
ON
COM.SET >> 8 MT-SICS
MT-PM
SART
BAUDRATE >> 8 9600
¦4800
BIT/PAR. >> 8 8/NO
7/NO
7/MARK
7/SPACE
7/EVEN
7/ODD
STOPBIT >> 8 1 BIT
2 BITS
HD.SHAKE >> 8 XON/XOFF
RTS/CTS
OFF
RS.TX.E.O.L.>> 8 <CR><LF>
<CR>
<LF>
<TAB>
RS CHAR >> 8 IBM/DOS
ANSI/WIN
USB >> 8 PC-DIR. >>. 8 PRT.STAB
PRT.AUTO
PRT.ALL
HOST >> 8 SEND.OFF
SEND.STB
SEND.CONT
SEND.AUTO
SEND.ALL
USB COMS.>> MT-SICS
MT-PM
SART
USB E.O.L.>> 8 <CR><LF>
<CR>
<LF>
<TAB>
USB CHAR>> 8 ANSI/WIN
IBM/DOS
INTERVAL>> 8 0 s
Topic SelectionPROTECT>> 8 OFF
ON
Protection
Legend Factory setting Only those weight units allowed by the appropriate
national legislation are selectable. Not available with MSxxxE models. Not available with MSxxxKLIPE models. Not available with approved models. Not available with approved models
(except OIML accuracy class I approved models)¥ Settings are automatically set for the 2nd display.
Software version V2.20
For more information
600…38400