quickstart “basic” installation guidelines for 1802 and

2
120 S. Glasgow Avenue Inglewood, California 90301 U.S.A. Surface Mount Flush Mount 7 8 9 4 5 6 1 2 3 0 OPERATING INSTRUCTIONS Locate Code Number on Directory. Press Code Number. If Line is Busy, Press Any Button to Hang Up. Try Again. Enter on Tone. 1. 2. 3. 7 8 9 4 5 6 1 2 3 0 OPERATING INSTRUCTIONS Locate Code Number on Directory. Press Code Number. If Line is Busy, Press Any Button to Hang Up. Try Again. Enter on Tone. 1. 2. 3. It is highly recommended that you consult the Installation/Owner’s manual for complete instructions on all the different types of installations. The 1802 Telephone Entry System involves the installation of the 1802 enclosure and conduit runs for all necessary wiring (On reverse side). Be sure that all dirt, metal or wood debris is removed from inside enclosure after mounting it. This could damage the control board and cause a malfunction during operation. Install Enclosure 1. Mount the enclosure using the mounting holes provided in the corners. Be sure that mounting screws or nuts (Not supplied) do not protrude into the enclosure where they could cause a short on the back of the circuit board. Make any necessary conduit connections through the back or bottom of the enclosure using the existing conduit knock-outs. 2. Route all wiring through conduit and wire accordingly (see reverse side for wiring). 3. Re-install components back into the enclosure. There are different styles of DoorKing mounting posts. All mounting posts need the adapter plate (P/N 1802-111) to mount the 1802. Surface mount models ONLY. Use hardware supplied with mounting post and adapter plate to secure enclosure. DoorKing offers a self-standing lighted kiosk for the flush mount unit ideal for walk-up pedestrian applications (P/N 1200-160). Use appropriate hardware to secure enclosure to the wall (not supplied). Mount ON a Surface Mount IN a Surface Mount to a Mounting Post Mount in a DoorKing Kiosk Mounting Screws (Not supplied) Examples of conduit runs that may be used, depending on how you choose to run the wiring. Some installations will allow the conduit to be run outside the wall and connect to the bottom of the enclosure but this is generally NOT recommended. Run all wires inside post. Conduit run to junction box Conduit sweep run Wall Mfg. in U.S.A. DOORKING Inglewood, Ca 90301 Model # 1800 Series Serial # Complies F.C.C. Part 68 F.C.C. Registration # DUF6VT-12874-OT-T Ringer Equiv. 0.0A Jack USOC RJ11C or W ACCESS CONTROL SYSTEM UNITS CONFORMS TO UL STD 294 OUTDOOR USE / WET Knock-outs Knock-outs Mounting Screws (Supplied) Wall Rough-In Box Flush Mount Enclosure Adapter Plate Surface Mount Enclosure Surface Mount Enclosure Circuit Board Screw Main Terminal Screw Ribbon Cable Scroll Buttons Cable Connector 1802EPD ONLY Ground Wire Locknut Faceplate Main Terminal Discharge any static BEFORE removing the circuit board by touching a proper ground device. Remove Components from Enclosure 1. Disconnect cable(s) from the circuit board. 2. Unscrew 1 circuit board screw and GENTLY remove the circuit board. 3. Unscrew main terminal and remove the ground wire locknut. 4. Remove two locknuts from the faceplate hinge. 5. Remove the faceplate, main terminal (still wired) and store them in a Safe Place until they need to be re-installed. There are 2 different models of the 1802 telephone entry system - Standard 1802 and 1802EPD which has an electronic program- mable directory with scroll buttons. Components removal is the same for the surface mount and flush mount units. DOORKI NG , I NC. Mfg. in U.S.A. Access Control Solutions Since 1948 This product is manufactured under one or more of the following U. S. Patents. OTHER PATENTS PENDING DOORKING INC., INGLEWOOD CA Patent No. Date Patent No. Date DOORKING Inglewood, Ca 90301 Model # 1800 Series Serial # Complies F.C.C. Part 68 F.C.C. Registration # DUF6VT-12874-OT-T Ringer Equiv. 0.0A Jack USOC RJ11C or W ACCESS CONTROL SYSTEM UNITS CONFORMS TO UL STD 294 OUTDOOR USE / WET 16AC 16AC NO NC C BAT COM SPKR MIC MICG PSW CGND PHONE RING ON CLCK SENSE SPK VOL FEEDBACK MIC VOL OFF KEYPAD MASTER CODE NO HS TONE OFF TONE ON HF NC C CONTRAST DOORKING 1862-010 1810-075 sn XX THIS SIDE UP 0000010100010 1802 Surface Mount Enclosure DOORKI NG , I NC. MADE IN USA PART NUMBER REV SERIAL NO. Faceplate Hinge Locknuts QUICKSTART “BASIC” INSTALLATION GUIDELINES FOR 1802 and 1802EPD

Upload: others

Post on 06-Apr-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

120 S. Glasgow AvenueInglewood, California 90301

U.S.A.

Surface MountFlush Mount

78

9

45

6

12

3

0OPERATING

INSTRUCTIONS

Locate Code Number on

Directory.Press Code Number.

If Line is Busy, Press Any

Button to Hang Up.

Try Again.Enter on Tone.

1.

2.

3.

78

9

45

6

12

3

0OPERATING

INSTRUCTIONS

Locate Code Number on

Directory.Press Code Number.

If Line is Busy, Press Any

Button to Hang Up.

Try Again.Enter on Tone.

1.

2.

3.

It is highly recommended that you consult the Installation/Owner’s manual for complete instructions on all the different types of installations. The 1802 Telephone Entry System involves the installation of the 1802 enclosure and conduit runs for all necessary wiring (On reverse side). Be sure that all dirt, metal or wood debris is removed from inside enclosure after mounting it. This could damage the control board and cause a malfunction during operation.

Install Enclosure1. Mount the enclosure using the mounting holes provided in the corners. Be sure that mounting screws or nuts (Not supplied) do not protrude into the enclosure where they could cause a short on the back of the circuit board. Make any necessary conduit connections through the back or bottom of the enclosure using the existing conduit knock-outs.2. Route all wiring through conduit and wire accordingly(see reverse side for wiring).3. Re-install components back into the enclosure.

There are different styles of DoorKing mounting posts. All mounting posts need the adapter plate (P/N 1802-111) to mount the 1802. Surface mount models ONLY.

Use hardware supplied with mounting post and adapter plate to secure enclosure.

DoorKing offers a self-standing lighted kiosk for the flush mount unit ideal for walk-up pedestrian applications(P/N 1200-160).

Use appropriate hardware to secure enclosure to the wall (not supplied).

Mount ON a Surface

Mount IN a Surface

Mount to a Mounting Post

Mount in a DoorKing Kiosk

Mounting Screws

(Not supplied)

Examples of conduit runs that may be used, depending on how you choose to run the wiring. Some installations will allow the conduit to be run outside the wall and connect to the bottom of the enclosure but this is generally NOT recommended.

Run all wires inside post.

Conduit runto junction box

Conduitsweep run

WallD O

O R KI N

G® , I NC .

Mfg. in U.S.A.

Access Control S

olutions

Since 1948

This product is m

anufactured under one

or more of th

e follo

wing U. S. P

atents.

OTHER PATENTS PENDING

DOORKING INC., I

NGLEWOOD CA

Patent No.

Date

Patent No.

Date

DO

OR

KIN

GIn

gle

wood, C

a 90301

Model

# 1

800 S

erie

sS

eria

l #C

om

plie

s F.

C.C

. P

art

68

F.C

.C. R

egis

trat

ion #

DU

F6V

T-12874-O

T-T

Rin

ger

Equiv

. 0.0

AJa

ck U

SO

C R

J11C

or

W

AC

CE

SS

CO

NT

RO

LS

YS

TE

M U

NIT

S

CO

NF

OR

MS

TO

UL

ST

D 2

94

OU

TD

OO

R U

SE

/ W

ET

Knock-outs

Knock-outs

Mounting Screws(Supplied)

Wall

Rough-InBox

Flush MountEnclosure

AdapterPlate

SurfaceMountEnclosure

SurfaceMountEnclosure

Circuit BoardScrew

Main Terminal Screw

RibbonCable

ScrollButtonsCableConnector1802EPDONLY

GroundWire Locknut

Faceplate

Main Terminal

Discharge any static BEFORE removing the circuit board by touching a proper

ground device.

Remove Components from Enclosure

1. Disconnect cable(s) from the circuit board.

2. Unscrew 1 circuit board screw and GENTLY remove the circuit board.

3. Unscrew main terminal and remove the ground wire locknut.

4. Remove two locknuts from the faceplate hinge.

5. Remove the faceplate, main terminal (still wired) and store them in a Safe Place until they need to be re-installed.

There are 2 different models of the 1802 telephone entry system - Standard 1802 and 1802EPD which has an electronic program-mable directory with scroll buttons. Components removal is the same for the surface mount and flush mount units.

D OO R K

I NG® , I N

C .

Mfg. in U.S.A.

Access Control S

olutions

Since 1948

This product is m

anufactured under one

or more of th

e follo

wing U. S. P

atents.

OTHER PATENTS PENDING

DOORKING INC., I

NGLEWOOD CA

Patent No.

Date

Patent No.

Date

DO

OR

KIN

GIn

gle

wood, C

a 90301

Model

# 1

800 S

erie

sS

eria

l #C

om

plie

s F.

C.C

. P

art

68

F.C

.C. R

egis

trat

ion #

DU

F6V

T-12874-O

T-T

Rin

ger

Equiv

. 0.0

AJa

ck U

SO

C R

J11C

or

W

AC

CES

S C

ON

TR

OL

SY

STEM

UN

ITS

CO

NFO

RM

S T

O U

L S

TD

294

OU

TD

OO

R U

SE /

WET

16AC

16AC

NONC

CBAT

COM

SPKR

MIC

MICG

PSW

CGND

PHONE

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

MASTERCODE

NO

HS

TONEOFF

TONEON

HF

NCC

CONTRASTDOORKING 1862-010

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

1802

Surface

Mount

Enclosure

D O O R K I N G ® , I N C .MADEINUSA

PART NUMBER

REV

SERIAL NO.

FaceplateHingeLocknuts

QUICKSTART “BASIC” INSTALLATION GUIDELINES FOR 1802 and 1802EPD

120 S. Glasgow AvenueInglewood, California 90301

U.S.A.

RING

ON

CLCKSENSE

SPKVOL

FEEDBACK

MIC VOL

OFF

KEYPAD

3 2 1

3 2 1

3 2 1

MASTERCODE

NOHSTONE

OFF

TONEON

HF

NC C

CONTRAST DOORKING 1862-010

16AC16ACBAT NONCCCOMSPKRMICMICGPSWCGNDPHONE

1810

-075

sn X

XTH

IS S

IDE

UP

0000

0101

0001

0

? ? ? ?02

101

? ? ? ?10

1 9 0 4 3 5 9 6 6 7 9

Door Control Gate Control

Main Terminal

Door Locks

Gate Operator

Power for electric strike or magnetic lock is NOT provided by the system. Use separate UL listed power supply.

Magnetic lock is wired to the Normally Closed (NC)

relay input 1.

Electric strike is wired to Normally Open (NO)

relay input 1.

Gate Operator is wired to Normally Open (NO) relay input 1.

Lock PowerUL listed

To Relay Input 1To Relay Input 1

DoorLock

Wiring MUST be twisted and completely isolated from ground.

Phone Line

Central OfficePhone Line Inputtouch tone, loop start

Earth Ground1802 MUST be Properly Grounded!

Relay Input 1“NO” - Normally Open (NO)

“NC” - Normally Closed (NC)“C” - Common (C)

Power Input16.5 VDC, 20 VA power.

Wire Size Distance18 AWG16 AWG

Up to 100 ftUp to 200 ft

Wire Size Distance24 AWG22 AWG

Up to 800 ftUp to 1600 ft

Speaker Adjust

Microphone Adjust

Feedback Adjust

FerriteFilter

The 1802 is programmed from the factory with “9 9 9 9” as the default “Master Code”. It can be re-programmed if desired.

1. Turn Master Code switch ON.

2. Choose and enter a four digit Master Code number, then press “*”, “beep” will be heard.

3. Turn Master Code switch OFF.

Switch OFF - Normal operating mode positon.

Switch ON - After master code switch has been turned ON, system will be in Master Code programming mode. (If master code switch is turned ON and master code is not entered, the system will sound a short tone after 30 seconds and continue every 30 seconds until master code is entered or switch is turned off).

Master Code Switch Description

Re-Programming the “Master Code”

MASTER CODE

ON

OFF

ON

OFF

(Write down your master code).

Set the directory code length to 1 - 2 - 3 or 4 digits.If 11 or more residents are going to be programmed into the system, the directory code length must be at least two-digits.If 101 or more residents are going to be programmed in, the directory code length must be at least three-digits.The factory has already set this for three (3) digits but it can be changed if desired.

Program the Directory Code Length into System

1. Press and enter your four-digit MASTER CODE (beep). Note: Factory setting is “9999”.

2. Enter the directory code digit length (1, 2, 3 or 4), then press (beep).

3. Press (beep) to cancel this function, OR (beeeeeep) to confirm the change.

The programming sequence will automatically end itself after pressing . This CANNOT be UNDONE!

CAUTION: After programming this sequence, it is NOT recommended changing the directory code length. Re-programming this sequence in the future will delete ALL phone numbers and directory codes that have been previously programmed into the system.

Basic Programming Required

Basic Wiring Required

Basic Adjustments Required

Speaker volume, microphone volume and feedback ALL interact with each other to affect the audio performance of the system.1. Locate the speaker volume, microphone volume and feedback adjustments on circuit board. Place a phone call from the telephone entry system to a resident using a resident’s directory code.2. While they are talking, adjust the speaker volume for adequate sound.3. Talk to the resident in a normal voice to adjust the microphone volume. Ask the resident to let you know when the sound in their telephone is adequate.4. After speaker and microphone have been adjusted, ask the resident to remain silent.5. Remove the jumper from the TONE OFF terminals on the circuit board and place it on the TONE ON terminals. A tone will be heard in the speaker.6. Rotate the feedback adjustment. When the tone from the speaker is minimum, this is the correct adjustment.7. Jumper MUST be moved back to the TONE OFF terminals when complete.

3 2 1

MIC VOL

3 2 1 SPKVOL

FEEDBACK

3 2 1

Speaker Volume, Microphone and Feedback

TONEON TONE

OFF

Tone On/Off Jumper

Note: High microphone and speaker volume levels may cause feedback. It may be necessary to reduce the speaker volume if the microphone volume is set too high. Likewise, it may be necessary to reduce the microphone volume if the speaker volume is set too high.

Wire polarity does not matter

It is highly recommended that you consult the Installation/Owner’s manual for complete instructions on all wiring and programming.The 1802 needs wiring to an incoming telephone line, power wiring, connection to a entry door or gate and it MUST be properly grounded.The 1802 MUST have DIRECTORY CODES programmed into it to be able to contact the residents from the system. The resident will be able to GRANT ACCESS and open the door or gate by pressing “9” on their phone or DENY ACCESS by pressing “#” on their phone.

Relay 1 Strike Time Note: Relay 1 strike time is factory set for 1 second. Strike time can be re-programmed from 1/4 second up to 99 seconds. Refer to manual for re-programming if desired.

LCD Display - Welcome Note: The welcome message is factory set and will probably need to be re-programmed for your specific needs. Refer to manual for re-programming welcome message if desired.

LCD Display - 1802EPD ONLY Note: The electronic programmable display should have the resident names programmed into it after the directory codes have been programmed in. Refer to manual for programming names into the 1802EPD system.

1. Press and enter your four-digit MASTER CODE (beep).

2. Choose and enter a directory code (1, 2, 3 or 4 digits, depending on what was programmed above), then press (beep).

Note: Use the log tables in back of the 1802 manual to keep track of names, phone numbers and directory codes.

3. Enter the phone number (Up to 16-digits, but less digits will be accepted) for the chosen directory code, then press (beep).

Note: Entering the anywhere in the phone number (multiple #’s can be used) will cause the dialing sequence to pause(1-9 seconds) if necessary.

Programming Phone Numbers - Up to 16-Digits

Example: Phone number 1-904-359-6679 needs to be dialed with a pause after the 1.

Programming:

In this programming sequence, the directory codes and phone numbers (up to 16 digits) will be programmed into the system. If you use directory codes 0, 00, 000, 0000 and/or 1, 01, 001, 0001 remember that the talk time for these directory codes are factory set to the maximum and cannot be changed. Use these directory codes to program management or emergency phone numbers, which generally require longer conversation periods.

4. Repeat steps 2 and 3 to enter additional directory codes and phone numbers.

5. Press together to end this programming sequence (beeeeeep).0

? ? ? ?

QUICKSTART “BASIC” WIRING AND PROGRAMMING GUIDELINES FOR 1802 AND 1802EPD

Copyright 2019 DoorKing®, Inc. All rights reserved.1802-066 Issued 7-19

Version A