r410a , 50hz

60
R410a, 50Hz CMV Mini VRF SYSTEM

Upload: seda

Post on 20-Feb-2016

101 views

Category:

Documents


7 download

DESCRIPTION

CMV Mini VRF SYSTEM. R410a , 50Hz. Contents. Brief Introduction Advantages Indoor units Controllers. I. Brief Introduction. 01. Product Line Up 02. Outdoor units 03. Indoor Units Line up 04. Nomenclature. Brief Introduction. 01. Product Line Up. CHIGO commercial AC products. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: R410a ,  50Hz

R410a, 50Hz

CMV Mini VRF SYSTEM

Page 2: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Contents

I. Brief IntroductionII. AdvantagesIII. Indoor unitsIV. Controllers

Page 3: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

I. Brief Introduction

01. Product Line Up02. Outdoor units03. Indoor Units Line up04. Nomenclature

Page 4: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

01. Product Line Up

Brief Introduction

CHIGO commercial AC products

R410a,50HZ380V-415V/3Ph;220V-240V/1ph

Mini VRF LCACAir-cooled scroll chiller VRF

10KW 16KW14KW12.5KW

Page 5: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

4 models All outdoor

units have same size 10KW /12.5KW/14KW/16KW

Brief Introduction02. Outdoor Units

Each outdoor unit can connect more than one indoor unit, MAXIMUM 8 units can be connected.

Page 6: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Specifications CMV-V100W/ZR1-B CMV-V125W/ZR1-B CMV-V140W/ZR1-B CMV-V160W/ZR1-B

Cooling mode

Capacity 10KW 12.5KW 14KW 16KW

Input 2.69KW 3.38KW 3.98KW 4.58KW

Heating mode

Capacity 11.5KW 14KW 16KW 18.5KW

Input 2.91KW 3.66KW 4.3KW 5.13KW

Size W*H*D mm 900*1328*345

Noise level dB(A) 45 ~ 58

Max connected indoor unit quantity 6 6 7 8

380V-415V/3PH/50HZ ; 220V-240V/1PH/50HZ

02. Outdoor Units

Page 7: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

03. Indoor Units Line Up

Cap.(kW)

4-way

cassette4-way cassette (compact type)

Wall-mountedLow ESP

ducted unitMedium ESP ducted unit

High ESP ducted unit

Floor CeilingFresh air processor

               

2.2   ● ● ●        2.8 ● ● ● ●        3.2       ●        3.6 ● ● ● ●        4.5 ● ● ● ●     ●  5.6 ●   ● ●     ●  7.1 ●   ● ● ● ● ●  8.0 ●       ● ● ●  9.0 ●       ● ● ●  

10.0 ●       ● ●    11.2 ●           ●  12.0         ● ●    12.5 ●              14.0 ●           ● ●

15.0         ● ●    16.0 ●           ●  

Brief Introduction

Page 8: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Brief Introduction04. How To Read The Model NameCMV- V100W / Z R1 B-

Refrigerant type R1: R410a Power supply Z: 380-415V/3PH/50Hz Omit:220-240V/1PH/50Hz

Outdoor unit

Chigo VRF system

Capacity (*100W)

Compressor code V: Inverter

Design code B: 2nd generation

Page 9: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

04. How To Read The Model Name

Brief Introduction

Refrigerant type R1: R410a Function code H: Heat pump Indoor unit code Q: 4-way cassette G: Wall-mounted TA: Low ESP ducted TB: Medium ESP ducted TH: High ESP ducted LD: Floor ceiling

Chigo VRF system

Capacity (*100W)

Compressor code V: Inverter

CMV- V125TB / H R1 B- Design code B: 2nd generation

Page 10: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

II. Advantages

01. High efficiency02. Benefit for users03. Benefits For Installers04. Doctor Kit

Page 11: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

01. High Efficiency

Page 12: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

High Efficiency01. High Efficiency DC Inverter Compressor Twin-rotor DC

inverter compressor• Rotating speed

can be down to 20RPS

• Has very good efficiency in part load condition

High efficiency

Low vibration

High reliability

Long life

Low noise

Page 13: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

High Efficiency01. High Efficiency DC Inverter Compressor

Environmental Protection: Developed the compressor with alternative refrigerant which can protect environment.

High Efficiency, Low Noise:Optimized the efficiency and noise during operation with the latest technology.

Low Vibration:Reduced the vibration during compressor start and operation by using 2CYL Structure, simplified the match of air-conditioning.

Page 14: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

ACmotor

High Efficiency02. High Efficiency DC Motor

High efficiency DC fan motor

Low noise and high efficiency because of high-density wire winding engineering

Brushless with built-in sensor

•Low efficiency•Big noise•Not adjustable

Page 15: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

High Efficiency03. DC Motor Stepless Control

DC fan motor can be stepless controlled by outdoor PCB according to system's operating temperature and frequency. And it is able to reduce the energy consumption and maintain the system in the best performance. Energy wasted

Low performance

0% 100% 130%

1200

700

50%Load

Revolution (rpm)

200

1400

DC motor stepless adjustmentAC motor 2-speed adjustment

50% energy

saved

Page 16: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

High Efficiency04. 180˚ Sine Wave Control

The perfect combination of 180˚ Sine wave rotor frequency drive control technology and excellent IPM inverters, reduces the reactive loss of motor-driven, increases motor efficiency by 12%.

180˚ Sine Wave vector Control

Conventional control waveform

Increase efficiency by

12%

Page 17: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Coef

fici

ent o

f hea

t tra

nsf

er, k

W/(

m2 ·

K)

Refrigerant mass flow, kg/(m2·K)

6

5

4

100 200 300 400

High Efficiency05. CCT Inner-grooved Tube

CCT (Continuous Cooling Transformation) inner-grooved copper tube has high thermometric conductivity. Its inner-grooved fins break the refrigerant flow boundary layer to enhance refrigerant disturbance to increase heat-exchanging efficiency.

CCT Inner-grooved Tube

Conventional Tube

Page 18: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

High Efficiency06. High Performance Heat Exchanger Has low air resistance and great heat transfer

coefficient Frosting improved, frost on the heat-exchanger will

be well-distributed, easy for defrosting.

Coe

ffic

ient

of h

eat t

rans

fer

kW

/(m2 ·K

)

Face velocity, m/s

300

200

1000 2 4

Cross Flow FinsConventional Fins

Page 19: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

02. Benefits For Users

Page 20: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Users01. Excellent In Efficiency

Thanks to DC devices(compressor and motor), piping optimization design and new control logic, system's EER and COP are observably increase.

10KW 12.5KW 14KW 16KW Average0

1

2

3

4

5

3.73 3.70 3.54 3.50 3.623.97 3.84 3.72 3.61 3.78

Cooling EERHeating COP

Page 21: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Users02. Outstanding Comfort Ability

Precisely room temperature control by adopting large pulse EXV. Indoor temperature fluctuation can be maintain within 0.5 ˚C, offers outstanding comfort ability.

Time

Room Temperature

25oC ±0.5˚C

Conventional fixed speed systemMini VRF

Page 22: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Some indoor unit get to set point

Benefits For Users02. Fast cooling and heating

Every rooms meet set point most quickly and comfortably by optimized refrigerant control.

Normally running

Stop @ Set point

Stop @ Set point

Page 23: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Users03. Wide Outdoor Operation Range.

Because global warming is getting worse, Max. cooling operating temperature is increased to 50˚C,

0 ˚C 10 ˚C 20 ˚C 30 ˚C 40 ˚C 50 ˚C-10˚C

-5˚C 50˚CCooling range

-20˚C 30˚CHeating range

-10˚C 0˚C 10 ˚C 20 ˚C 30˚C-20˚C

Heating operating temperature is down to -20˚C. In the cold winter, system can heat the room continuously.

Page 24: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Users05. Intelligent Defrosting Program

Program starts only when unit needs to. Whereas conventional unit's defrosting timing & duration is fixed, causing fluctuations in temperature and personal comfort.

Time

Hea

tin

g Ca

pac

ity

outp

ut

Conventional program

Intelligent defrosting program Conventional unit's defrosting timing & duration is fixed

Intelligent defrosting program starts according to heat exchanging efficiency & capacity change due to the frost. Less temperature fluctuations, people feel more comfortable.

Page 25: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Users06. Fan Reversal Protection

In standby, if the outdoor fan motor is rotating in opposite direction at a high speed by the wind or other natural factors, the unit can’t start so as to keep the fan motor from broken down. It will start when the fan motor speed slow down.

Page 26: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Users07. Flexible For All Kinds Of Rooms

8 types & 55 models of indoor units, suitable for all kinds of rooms.

Page 27: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

03. Benefits For Installers

Page 28: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers01. Long Pipe & Height Difference.

The total pipe length: 125 m

The longest pipe length: 50 m

Height deference: 30 m Height difference

between indoor units: 15 m

Length from first indoor distributor to last indoor

unit: 25 m

<25m<50m

<15m<30m

Page 29: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers02. Space saving installation

Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible.

Compare to one-drive-one type, the outdoor unit can be installed in various places to realize the space-saving installation.

Page 30: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers03. Addressing Methods

Automatically addressing: system will distribute address to indoor unit automatically

Automatic addressing will reduce artificial faults and manual works.

Page 31: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers04. Automatic Addressing

Automatic addressing will reduce artificial faults and manual works.• 54% system failure were caused by

communication faults. • 65% communication faults were caused by

address problems. • Most of the address problems were: address

setting forgotten, wrong settings, address repeat.

Failure chartCommunication faultsOthers

OthersAddressing problems

54%

65%⇨ Address faults was

awarded to the most

hated fault after had

investigated 120

VRF after-sale

engineers in 2011.

Page 32: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers05. LED Display On PCB

LED display on the PCB, it can show system's operation status and error codes.

Page 33: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers06. Mode Restriction

5 kinds of mode restriction• First start indoor

units priority mode

• Cooling (or heating) priority mode

• Cooling only (or heating only) mode

Mode restriction function can be selected on the outdoor PCB.

Page 34: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers7. Oil Control Technology

Core oil control technology makes system safety & reliable.

Oil level control

Oil even pipe

Intelligent oil return program Oil separator

Separation efficiency 92%

Page 35: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Benefits For Installers8. 3-phase Power Protector (Optional Device)

Protect the outdoor unit from instable voltage.

Page 36: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

04. Doctor Kit

Page 37: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Doctor Kit01. Easy To Use

Doctor Kit includes: 1 CD software and RS485-USB converter, easy to install

Graphical interfaces, easy to use

Page 38: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Doctor Kit02. Data Monitoring

We can use computer to inquiry outdoor unit's operating status, error codes when connecting to Doctor Kit.

Compressors, sensors, valves operating parameter can be real-time monitored.

System operating parameter curve can be real-time displayed.

Page 39: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Doctor Kit04. Troubleshooting

Built-in with troubleshooting instruction, user can follow the instruction to solve the problem when error happens.

User can also print out the instruction and take it to site to solve the problem step by step.

Page 40: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Doctor Kit05. Automatic Data Backup

Automatic Data Backup: all operating data will be saved on hard disk automatically. Data file can be exported easily by software.

When system failure, user can send the data file to Chigo, Chigo's engineer will check and guide you to solve the problem.

10 hours data = 1MB

Page 41: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Doctor Kit06. Charged Refrigerant Volume Calculator

Input the liquid pipe diameter and length, software will calculate the additional refrigerant charged volume.

Charged volume can be saved for future reference. Discharge pressure can be monitored when charging

refrigerant.

Page 42: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Ⅲ. Indoor Units01. 4-way cassette02. Wall-mounted03. Floor ceiling04. Low ESP Ducted type05. Medium ESP Ducted type06. High ESP Ducted type07. Full fresh air processor

Page 43: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Indoor Units01. 4-way Cassette

Standard type:• Capacity: 2.8 kW to 16 kW• Size: 840 × 893mm• Built-in with EXV and

water pump • Pumping head 750mm Compact type:• Capacity: 2.2 kW to 4.5 kW• Size: 580*580mm, • Built-in with EXV and

water pump • pumping head 700mm

Page 44: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Indoor Units02. Wall-mounted

Capacity: 2.2 kW to 7.1 kW 2 types of unit can be chosen:

EXV Built-in type EXV separated type

Compact size and low noise

Page 45: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Indoor Units03. Floor Ceiling

Capacity:4.5kW to 16.0kW Flexible installation:

• vertical or horizontal Built-in with EXV

Comfortable air delivery swing adjustment: • Left and right,• Up and down

Page 46: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Indoor Units04. Low ESP Ducted Type

Capacity 2.2 kW to 7.1 kW External static pressure: 20

Pa Built-in with EXV Low noise, and light weight Slim body, only 180 mm

height Air return box and filter is

optional

Page 47: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Air return from bottom

Air return for rear

Indoor Units05. Medium ESP Ducted Type

Capacity: 7 kW to 15 kW External static pressure:

70Pa Built-in with EXV Flexible installation, many

options Air return method can be site

changed

Page 48: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Indoor Units06. High ESP Ducted Type

Capacity: 7 kW to 15 kW External static pressure:

150Pa Built-in with EXV Suitable for long distance

air supply10.0kW / 12.0kW / 15.0kW

7.1kW / 8.0kW / 9.0kW

Page 49: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Ⅳ. Controllers and Software01. Wireless remote controller02. Wired controller03. Group controller04. BMS Gateway05. Centralized control system06. Doctor Kit07. CMV selection software

Page 50: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Controllers and software01. Wireless Remote Controller

Indoor unit address inquiry

Indoor unit address setting

Temperature setting Operation mode

setting Fan speed setting Timer function

OptionalStandard

Page 51: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Controllers and software02. New Wired Controller

Bidirectional communication. Indoor unit's operating parameters (error code, temperature, address) can be inquired and displayed on the controller.

Compact design 3'' screen with white

background light Timer function Electrical standard

dimensions

Page 52: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Controllers and software03. Group Controller

Easy to install. Controller connects to outdoor units only.

Able to install group controller after building decoration.

1 Controller can control max. 64 indoor units in different systems.

Page 53: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Controllers and software03. Group Controller

Wireless/wired control restriction

Operation mode restriction

Timer function Error or protection

code display

Page 54: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

BMS/BAS System Gateways

Mini CMV system

Controllers and software04. BMS Gateway

BACnet gateway Modbus gateway

Honeywell Siemens Johnson controls Etc…

……

BACnet

LonWorks

RS485

RS485

Page 55: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Controllers and software05. Centralized Control System

Billing function Operating report

output Schedule

management 1024 indoor unit can

be connected Control indoor units

with fully permissions.

Page 56: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Controllers and software06. Doctor Kit

Operating status, error codes inquiry

Compressors, sensors, valves operating parameter real-time monitored and display.

Commissioning results can be reported.

Built-in with troubleshooting instruction

Automatic Data Backup

Page 57: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

Controllers and software07. CMV Selection Software

Page 58: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

latest developments

Page 59: R410a ,  50Hz

CHIGO New Generation DC Inverter VRF System

latest developments1st time test of trail production is done.

Page 60: R410a ,  50Hz

Thank you!!