r410a , 50hz
DESCRIPTION
CMV Mini VRF SYSTEM. R410a , 50Hz. Contents. Brief Introduction Advantages Indoor units Controllers. I. Brief Introduction. 01. Product Line Up 02. Outdoor units 03. Indoor Units Line up 04. Nomenclature. Brief Introduction. 01. Product Line Up. CHIGO commercial AC products. - PowerPoint PPT PresentationTRANSCRIPT
R410a, 50Hz
CMV Mini VRF SYSTEM
CHIGO New Generation DC Inverter VRF System
Contents
I. Brief IntroductionII. AdvantagesIII. Indoor unitsIV. Controllers
CHIGO New Generation DC Inverter VRF System
I. Brief Introduction
01. Product Line Up02. Outdoor units03. Indoor Units Line up04. Nomenclature
CHIGO New Generation DC Inverter VRF System
01. Product Line Up
Brief Introduction
CHIGO commercial AC products
R410a,50HZ380V-415V/3Ph;220V-240V/1ph
Mini VRF LCACAir-cooled scroll chiller VRF
10KW 16KW14KW12.5KW
CHIGO New Generation DC Inverter VRF System
4 models All outdoor
units have same size 10KW /12.5KW/14KW/16KW
Brief Introduction02. Outdoor Units
Each outdoor unit can connect more than one indoor unit, MAXIMUM 8 units can be connected.
CHIGO New Generation DC Inverter VRF System
Specifications CMV-V100W/ZR1-B CMV-V125W/ZR1-B CMV-V140W/ZR1-B CMV-V160W/ZR1-B
Cooling mode
Capacity 10KW 12.5KW 14KW 16KW
Input 2.69KW 3.38KW 3.98KW 4.58KW
Heating mode
Capacity 11.5KW 14KW 16KW 18.5KW
Input 2.91KW 3.66KW 4.3KW 5.13KW
Size W*H*D mm 900*1328*345
Noise level dB(A) 45 ~ 58
Max connected indoor unit quantity 6 6 7 8
380V-415V/3PH/50HZ ; 220V-240V/1PH/50HZ
02. Outdoor Units
CHIGO New Generation DC Inverter VRF System
03. Indoor Units Line Up
Cap.(kW)
4-way
cassette4-way cassette (compact type)
Wall-mountedLow ESP
ducted unitMedium ESP ducted unit
High ESP ducted unit
Floor CeilingFresh air processor
2.2 ● ● ● 2.8 ● ● ● ● 3.2 ● 3.6 ● ● ● ● 4.5 ● ● ● ● ● 5.6 ● ● ● ● 7.1 ● ● ● ● ● ● 8.0 ● ● ● ● 9.0 ● ● ● ●
10.0 ● ● ● 11.2 ● ● 12.0 ● ● 12.5 ● 14.0 ● ● ●
15.0 ● ● 16.0 ● ●
Brief Introduction
CHIGO New Generation DC Inverter VRF System
Brief Introduction04. How To Read The Model NameCMV- V100W / Z R1 B-
Refrigerant type R1: R410a Power supply Z: 380-415V/3PH/50Hz Omit:220-240V/1PH/50Hz
Outdoor unit
Chigo VRF system
Capacity (*100W)
Compressor code V: Inverter
Design code B: 2nd generation
CHIGO New Generation DC Inverter VRF System
04. How To Read The Model Name
Brief Introduction
Refrigerant type R1: R410a Function code H: Heat pump Indoor unit code Q: 4-way cassette G: Wall-mounted TA: Low ESP ducted TB: Medium ESP ducted TH: High ESP ducted LD: Floor ceiling
Chigo VRF system
Capacity (*100W)
Compressor code V: Inverter
CMV- V125TB / H R1 B- Design code B: 2nd generation
CHIGO New Generation DC Inverter VRF System
II. Advantages
01. High efficiency02. Benefit for users03. Benefits For Installers04. Doctor Kit
CHIGO New Generation DC Inverter VRF System
01. High Efficiency
CHIGO New Generation DC Inverter VRF System
High Efficiency01. High Efficiency DC Inverter Compressor Twin-rotor DC
inverter compressor• Rotating speed
can be down to 20RPS
• Has very good efficiency in part load condition
High efficiency
Low vibration
High reliability
Long life
Low noise
CHIGO New Generation DC Inverter VRF System
High Efficiency01. High Efficiency DC Inverter Compressor
Environmental Protection: Developed the compressor with alternative refrigerant which can protect environment.
High Efficiency, Low Noise:Optimized the efficiency and noise during operation with the latest technology.
Low Vibration:Reduced the vibration during compressor start and operation by using 2CYL Structure, simplified the match of air-conditioning.
CHIGO New Generation DC Inverter VRF System
ACmotor
High Efficiency02. High Efficiency DC Motor
High efficiency DC fan motor
Low noise and high efficiency because of high-density wire winding engineering
Brushless with built-in sensor
•Low efficiency•Big noise•Not adjustable
CHIGO New Generation DC Inverter VRF System
High Efficiency03. DC Motor Stepless Control
DC fan motor can be stepless controlled by outdoor PCB according to system's operating temperature and frequency. And it is able to reduce the energy consumption and maintain the system in the best performance. Energy wasted
Low performance
0% 100% 130%
1200
700
50%Load
Revolution (rpm)
200
1400
DC motor stepless adjustmentAC motor 2-speed adjustment
50% energy
saved
CHIGO New Generation DC Inverter VRF System
High Efficiency04. 180˚ Sine Wave Control
The perfect combination of 180˚ Sine wave rotor frequency drive control technology and excellent IPM inverters, reduces the reactive loss of motor-driven, increases motor efficiency by 12%.
180˚ Sine Wave vector Control
Conventional control waveform
Increase efficiency by
12%
CHIGO New Generation DC Inverter VRF System
Coef
fici
ent o
f hea
t tra
nsf
er, k
W/(
m2 ·
K)
Refrigerant mass flow, kg/(m2·K)
6
5
4
100 200 300 400
High Efficiency05. CCT Inner-grooved Tube
CCT (Continuous Cooling Transformation) inner-grooved copper tube has high thermometric conductivity. Its inner-grooved fins break the refrigerant flow boundary layer to enhance refrigerant disturbance to increase heat-exchanging efficiency.
CCT Inner-grooved Tube
Conventional Tube
CHIGO New Generation DC Inverter VRF System
High Efficiency06. High Performance Heat Exchanger Has low air resistance and great heat transfer
coefficient Frosting improved, frost on the heat-exchanger will
be well-distributed, easy for defrosting.
Coe
ffic
ient
of h
eat t
rans
fer
kW
/(m2 ·K
)
Face velocity, m/s
300
200
1000 2 4
Cross Flow FinsConventional Fins
CHIGO New Generation DC Inverter VRF System
02. Benefits For Users
CHIGO New Generation DC Inverter VRF System
Benefits For Users01. Excellent In Efficiency
Thanks to DC devices(compressor and motor), piping optimization design and new control logic, system's EER and COP are observably increase.
10KW 12.5KW 14KW 16KW Average0
1
2
3
4
5
3.73 3.70 3.54 3.50 3.623.97 3.84 3.72 3.61 3.78
Cooling EERHeating COP
CHIGO New Generation DC Inverter VRF System
Benefits For Users02. Outstanding Comfort Ability
Precisely room temperature control by adopting large pulse EXV. Indoor temperature fluctuation can be maintain within 0.5 ˚C, offers outstanding comfort ability.
Time
Room Temperature
25oC ±0.5˚C
Conventional fixed speed systemMini VRF
CHIGO New Generation DC Inverter VRF System
Some indoor unit get to set point
Benefits For Users02. Fast cooling and heating
Every rooms meet set point most quickly and comfortably by optimized refrigerant control.
Normally running
Stop @ Set point
Stop @ Set point
CHIGO New Generation DC Inverter VRF System
Benefits For Users03. Wide Outdoor Operation Range.
Because global warming is getting worse, Max. cooling operating temperature is increased to 50˚C,
0 ˚C 10 ˚C 20 ˚C 30 ˚C 40 ˚C 50 ˚C-10˚C
-5˚C 50˚CCooling range
-20˚C 30˚CHeating range
-10˚C 0˚C 10 ˚C 20 ˚C 30˚C-20˚C
Heating operating temperature is down to -20˚C. In the cold winter, system can heat the room continuously.
CHIGO New Generation DC Inverter VRF System
Benefits For Users05. Intelligent Defrosting Program
Program starts only when unit needs to. Whereas conventional unit's defrosting timing & duration is fixed, causing fluctuations in temperature and personal comfort.
Time
Hea
tin
g Ca
pac
ity
outp
ut
Conventional program
Intelligent defrosting program Conventional unit's defrosting timing & duration is fixed
Intelligent defrosting program starts according to heat exchanging efficiency & capacity change due to the frost. Less temperature fluctuations, people feel more comfortable.
CHIGO New Generation DC Inverter VRF System
Benefits For Users06. Fan Reversal Protection
In standby, if the outdoor fan motor is rotating in opposite direction at a high speed by the wind or other natural factors, the unit can’t start so as to keep the fan motor from broken down. It will start when the fan motor speed slow down.
CHIGO New Generation DC Inverter VRF System
Benefits For Users07. Flexible For All Kinds Of Rooms
8 types & 55 models of indoor units, suitable for all kinds of rooms.
CHIGO New Generation DC Inverter VRF System
03. Benefits For Installers
CHIGO New Generation DC Inverter VRF System
Benefits For Installers01. Long Pipe & Height Difference.
The total pipe length: 125 m
The longest pipe length: 50 m
Height deference: 30 m Height difference
between indoor units: 15 m
Length from first indoor distributor to last indoor
unit: 25 m
<25m<50m
<15m<30m
CHIGO New Generation DC Inverter VRF System
Benefits For Installers02. Space saving installation
Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible.
Compare to one-drive-one type, the outdoor unit can be installed in various places to realize the space-saving installation.
CHIGO New Generation DC Inverter VRF System
Benefits For Installers03. Addressing Methods
Automatically addressing: system will distribute address to indoor unit automatically
Automatic addressing will reduce artificial faults and manual works.
CHIGO New Generation DC Inverter VRF System
Benefits For Installers04. Automatic Addressing
Automatic addressing will reduce artificial faults and manual works.• 54% system failure were caused by
communication faults. • 65% communication faults were caused by
address problems. • Most of the address problems were: address
setting forgotten, wrong settings, address repeat.
Failure chartCommunication faultsOthers
OthersAddressing problems
54%
65%⇨ Address faults was
awarded to the most
hated fault after had
investigated 120
VRF after-sale
engineers in 2011.
CHIGO New Generation DC Inverter VRF System
Benefits For Installers05. LED Display On PCB
LED display on the PCB, it can show system's operation status and error codes.
CHIGO New Generation DC Inverter VRF System
Benefits For Installers06. Mode Restriction
5 kinds of mode restriction• First start indoor
units priority mode
• Cooling (or heating) priority mode
• Cooling only (or heating only) mode
Mode restriction function can be selected on the outdoor PCB.
CHIGO New Generation DC Inverter VRF System
Benefits For Installers7. Oil Control Technology
Core oil control technology makes system safety & reliable.
Oil level control
Oil even pipe
Intelligent oil return program Oil separator
Separation efficiency 92%
CHIGO New Generation DC Inverter VRF System
Benefits For Installers8. 3-phase Power Protector (Optional Device)
Protect the outdoor unit from instable voltage.
CHIGO New Generation DC Inverter VRF System
04. Doctor Kit
CHIGO New Generation DC Inverter VRF System
Doctor Kit01. Easy To Use
Doctor Kit includes: 1 CD software and RS485-USB converter, easy to install
Graphical interfaces, easy to use
CHIGO New Generation DC Inverter VRF System
Doctor Kit02. Data Monitoring
We can use computer to inquiry outdoor unit's operating status, error codes when connecting to Doctor Kit.
Compressors, sensors, valves operating parameter can be real-time monitored.
System operating parameter curve can be real-time displayed.
CHIGO New Generation DC Inverter VRF System
Doctor Kit04. Troubleshooting
Built-in with troubleshooting instruction, user can follow the instruction to solve the problem when error happens.
User can also print out the instruction and take it to site to solve the problem step by step.
CHIGO New Generation DC Inverter VRF System
Doctor Kit05. Automatic Data Backup
Automatic Data Backup: all operating data will be saved on hard disk automatically. Data file can be exported easily by software.
When system failure, user can send the data file to Chigo, Chigo's engineer will check and guide you to solve the problem.
10 hours data = 1MB
CHIGO New Generation DC Inverter VRF System
Doctor Kit06. Charged Refrigerant Volume Calculator
Input the liquid pipe diameter and length, software will calculate the additional refrigerant charged volume.
Charged volume can be saved for future reference. Discharge pressure can be monitored when charging
refrigerant.
CHIGO New Generation DC Inverter VRF System
Ⅲ. Indoor Units01. 4-way cassette02. Wall-mounted03. Floor ceiling04. Low ESP Ducted type05. Medium ESP Ducted type06. High ESP Ducted type07. Full fresh air processor
CHIGO New Generation DC Inverter VRF System
Indoor Units01. 4-way Cassette
Standard type:• Capacity: 2.8 kW to 16 kW• Size: 840 × 893mm• Built-in with EXV and
water pump • Pumping head 750mm Compact type:• Capacity: 2.2 kW to 4.5 kW• Size: 580*580mm, • Built-in with EXV and
water pump • pumping head 700mm
CHIGO New Generation DC Inverter VRF System
Indoor Units02. Wall-mounted
Capacity: 2.2 kW to 7.1 kW 2 types of unit can be chosen:
EXV Built-in type EXV separated type
Compact size and low noise
CHIGO New Generation DC Inverter VRF System
Indoor Units03. Floor Ceiling
Capacity:4.5kW to 16.0kW Flexible installation:
• vertical or horizontal Built-in with EXV
Comfortable air delivery swing adjustment: • Left and right,• Up and down
CHIGO New Generation DC Inverter VRF System
Indoor Units04. Low ESP Ducted Type
Capacity 2.2 kW to 7.1 kW External static pressure: 20
Pa Built-in with EXV Low noise, and light weight Slim body, only 180 mm
height Air return box and filter is
optional
CHIGO New Generation DC Inverter VRF System
Air return from bottom
Air return for rear
Indoor Units05. Medium ESP Ducted Type
Capacity: 7 kW to 15 kW External static pressure:
70Pa Built-in with EXV Flexible installation, many
options Air return method can be site
changed
CHIGO New Generation DC Inverter VRF System
Indoor Units06. High ESP Ducted Type
Capacity: 7 kW to 15 kW External static pressure:
150Pa Built-in with EXV Suitable for long distance
air supply10.0kW / 12.0kW / 15.0kW
7.1kW / 8.0kW / 9.0kW
CHIGO New Generation DC Inverter VRF System
Ⅳ. Controllers and Software01. Wireless remote controller02. Wired controller03. Group controller04. BMS Gateway05. Centralized control system06. Doctor Kit07. CMV selection software
CHIGO New Generation DC Inverter VRF System
Controllers and software01. Wireless Remote Controller
Indoor unit address inquiry
Indoor unit address setting
Temperature setting Operation mode
setting Fan speed setting Timer function
OptionalStandard
CHIGO New Generation DC Inverter VRF System
Controllers and software02. New Wired Controller
Bidirectional communication. Indoor unit's operating parameters (error code, temperature, address) can be inquired and displayed on the controller.
Compact design 3'' screen with white
background light Timer function Electrical standard
dimensions
CHIGO New Generation DC Inverter VRF System
Controllers and software03. Group Controller
Easy to install. Controller connects to outdoor units only.
Able to install group controller after building decoration.
1 Controller can control max. 64 indoor units in different systems.
CHIGO New Generation DC Inverter VRF System
Controllers and software03. Group Controller
Wireless/wired control restriction
Operation mode restriction
Timer function Error or protection
code display
CHIGO New Generation DC Inverter VRF System
BMS/BAS System Gateways
Mini CMV system
Controllers and software04. BMS Gateway
BACnet gateway Modbus gateway
Honeywell Siemens Johnson controls Etc…
……
BACnet
LonWorks
RS485
RS485
CHIGO New Generation DC Inverter VRF System
Controllers and software05. Centralized Control System
Billing function Operating report
output Schedule
management 1024 indoor unit can
be connected Control indoor units
with fully permissions.
CHIGO New Generation DC Inverter VRF System
Controllers and software06. Doctor Kit
Operating status, error codes inquiry
Compressors, sensors, valves operating parameter real-time monitored and display.
Commissioning results can be reported.
Built-in with troubleshooting instruction
Automatic Data Backup
CHIGO New Generation DC Inverter VRF System
Controllers and software07. CMV Selection Software
CHIGO New Generation DC Inverter VRF System
latest developments
CHIGO New Generation DC Inverter VRF System
latest developments1st time test of trail production is done.
Thank you!!