rac - eviss.bg · 2015. 5. 13. · ecodesign (e.r.p.) 8 staging unit a staging unit b rac catalogue...

56
2015 Catalogue RAC Room Air Conditioning Air Conditioning

Upload: others

Post on 19-Feb-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

  • 2015 Catalogue

    RACRoom Air Conditioning

    Air Conditioning

  • www.hitachi.com

  • 2015 Catalogue

    This is Hitachi page 04

    ErP design page 08

    Technology page 10

    Products

    RAC Mono page 15

    RAC Multi page 35

    Product comparison page 48

    Functions page 50

    Quality certifi cations page 55

    RAC

  • RAC

    4 RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

    RAC

  • RAC ResidentialMeet MIRAI

    My name is MIRAI and I will be your guide in

    the world of HITACHI air conditioning.

    The word MIRAI means FUTURE in Japanese

    and I represent HITACHI's ability to predict in

    advance customers' needs in air conditioning

    products and solutions.

    HITACHI's work philosophy is founded exactly

    on this principle: every year we invest a por-

    tion of our corporate earnings in the research

    and development of new products in line with

    the market's exacting demands, yet respect-

    ing and safeguarding the environment.

    With this spirit, our abilities, our ongoing com-

    mitment, we have been continuously growing

    for more than 100 years and we are not going

    to stop!

    Con� dent in our solid past but with our eyes

    � rmly set on the future...

    This is HITACHI! I am MIRAI!

    5RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • Company Profi le

    In 2012 HITACHI widened their activities by

    setting up HITACHI Air Conditioning Europe

    SAS.

    HITACHI Air Conditioning Europe encom-

    passes all Air Conditioning operations in

    the European market, including sales and

    production.

    Air conditioning according to HITACHI

    means more innovative ideas, the most

    recent technological developments and,

    together with engineering and quality

    control processes, producing systems to

    improve life in a home and professional en-

    vironment.

    In producing its range of innovative prod-

    ucts, HITACHI has a responsible and en-

    vironmentally-friendly approach which im-

    bues every activity within the process, from

    Hitachi Air Conditioning Products Europe - HAPE Production facility - Barcelona, Spain

    the � rst design stage of a new product, to

    production, to installation and operation

    procedures, guaranteeing products ‘Engi-

    neered for tomorrow’.

    HITACHI is committed to supplying prod-

    ucts of outstanding quality with the highest

    efficiency levels and the best cost-effective-

    ness. Achieving success with such ambi-

    tious goals on a global scale does not only

    involve committing considerable resources,

    but also implies a bold bet and huge com-

    mitment to the future.

    Among the most prominent companies

    worldwide, with about 360,000 employees,

    HITACHI can build on their expertise and

    knowledge, in the awareness it has been

    successfully addressing customers' chang-

    ing needs for more than a century. Our de-

    6

    Staging Unit A Staging Unit B

    Company Profi le

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    Hitachi Air Conditioning Systems Co., Ltd. - Production facility - Shimizu, Japan

    Hitachi Air Conditioning Products (M) - HAPM Production Facility - Kuala Lumpur, Malaysia

    sign and development skills are second to

    none and HITACHI is � rmly ready to face

    the future with serenity and con� dence.

    HITACHI – the name means “Rising Sun” in

    Japanese – is at the forefront in research

    and development, along a path led by

    substantial investments. About 4.2% of its

    worldwide 2010* $112,2 billion turn-over

    has been invested in research and devel-

    opment programs. This allows HITACHI

    to boast a wide number of “world's � rst”

    products, such as the acclaimed and tech-

    nologically advanced scroll compressors

    and semi-hermetic screw compressors.

    HITACHI compressors have revolutionised

    the air-conditioning world.

    The design process starts in Japan's work-

    shops and production units and is continu-

    ously developed via an exchange with the

    other units worldwide.

    HITACHI Air Conditioning products are

    sought after worldwide, whenever there is

    a need for high-efficiency products with the

    best price-quality ratio and an extremely

    long life. The widest product range, matched

    to an adequate set of electronic controls, al-

    lows HITACHI to offer solutions for any ap-

    plication or technical speci� cation.

    The innovative HITACHI production facility

    and training centre set up in Barcelona,

    Spain (HAPE) is tailored to the European

    market. The technologies used afford sig-

    ni� cant savings in production costs, fast

    deliveries and prompt support in meeting

    customers' needs.

    In addition to the technical support provid-

    ed by HITACHI Air Conditioning Europe, the

    local units contribute with their abilities and

    know-how to supporting customers from

    design to after-sale service in starting up

    and controlling systems.

    The after-sale service relies on a network

    of selected professionals and an extremely

    fast support in spare parts.

    To meet your air conditioning and heating

    needs and to assure air quality in your en-

    vironment, consider HITACHI Air Condition-

    ing Europe as your partner, able to guide

    you in all air conditioning choices and ‘In-

    spiring the Next ...’

    7RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • EcoDesign (E.r.P.)

    8

    Staging Unit A Staging Unit B

    EcoDesign (E.r.P.)

    RAC Catalogue 2015 - Air Conditioning

    Europe has revisited the original EcoDesign Directive (Directive

    2005/32/CE) and widened its � eld of application in order to achieve

    European 3 x 20 environmental goals (-20% energy consumption,

    -20% CO2 emissions, +20% renewable energies) by 2020.

    The initial scope of EcoDesign was E.u.P. (Energy using Products).

    However, the present scope of EcoDesign encompasses all prod-

    ucts that are connected to the use of energy (e.g.: windows, pan-

    elling) and it has been more correctly named E.r.P. (Energy related

    Products).

    EcoDesign means taking into consideration the environmental as-

    pects of every product/service in question.

    This approach consists in considering CO2 emissions and energy

    consumption throughout the entire life of the product (from design to

    end of life, including transport).

    The EcoDesign analysis highlights that the greatest environmental

    impact arises from the utilisation period of the products. For this

    reason, ErP sets minimum compulsory efficiency levels to enter the

    European market. At the same time, Erp requires the disclosure of

    technical data to users through a label which must show efficiency

    data and noise level, with the aim of assisting consumers in their

    choices.

    ErP applies to every conditioning and heating system independent-

    ly from the type (air/air, air/water, water/water, boilers...), capacity,

    utilisation (heating, conditioning, DHW) via a range of “Lots” and

    different time frames. The � rst Lot in force as of 1st January 2013

    is “Lot 10”. It covers all air conditioners (air/air), with capacity lower

    than 12kW, operating in conditioning and/or heating.

    A Directive to address European environmental emission reduction goals

    What does EcoDesign mean?

    ErP concerning conditioning and heating systems

    3 fundamental aspects in terms of compliance are described in

    Directive 2010/30/UE No.626/2011 of 4 May 2011 and in Directive

    2009/125/EC No.206/2012 of 6 March 2012.

    (a) De� nition of the minimum efficiency level in heating and con-

    ditioning

    (b) De� nition of the Sound Power level for internal and external

    unit at nominal conditions

    (c) De� nition of the criteria for communication to the user by

    means of the label

    «Nominal COP» de� nes the efficiency of the system in one meas-

    uring point: +7°C outside, +20°C inside, compressor at nominal

    speed.

    «SCOP» de� nes the system's seasonal efficiency, considering:

    5 measuring points: -10°C, -7°C, +2°C, +7°C, +12°C outside,

    +20°C inside

    Different compressor speeds (full load and partial load). Ancillary

    consumptions (oil heater, thermostat off mode, off mode, stand-

    by…)

    Temperature conditions for an identi� ed climate (obligatory aver-

    age climate, optional hot climate and cold climate) and number of

    operating hours depending on outdoor temperatures

    Thermal load of the building (called Pdesign)

    For these reasons, the SCOP (and SEER) give a more accurate

    estimate of the actual efficiency of a system throughout the entire

    time of utilisation.

    Table of minimum SCOP/SEER values for compliance

    Main differences between nominal COP and SCOP :

    Fundamental aspects of Lot 10

    The application date is 1st January 2013.

    However, levels (a) and (b) will be increased every year and label-

    ling will be updated every 2 years.

    The efficiency level (a) refers to seasonal efficiency of the system,

    called SCOP (heating) and SEER (conditioning) for the average

    European climate. This efficiency coefficient is going to replace the

    previous COP and EER values.

    Energy rating

    A

    A +++

    B

    A ++

    C

    A +

    D

    Energy rating

    3.40 ≤ SCOP < 4.00

    SCOP ≤ 5.10

    4.60 ≤ SCOP < 5.10

    4.00 ≤ SCOP < 4.60

    SEER

    5.10 ≤ SEER ≥ 5.60

    SEER 8.50

    4.60 ≤ SEER ≥ 5.10

    6.10 ≤ SEER ≥ 8.50

    4.10 ≤ SEER ≥ 4.60

    5.60 ≤ SEER ≥ 6.10

    3.60 ≤ SEER ≥ 4.10

  • RAC Residential

    9RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

    http://erpactive.hitachiaircon.com

    Climate considered by ErP Reference temperature “T design”

    Average - 10° C

    Cold - 22° C

    Hot + 2° C

    Sound power of the internal and external unit at nominal capacity

    Yearly Kwh

    used in cooling and heating mode calculated under

    the Regulations

    Note:

    The manufacturer may choose to declare the data

    for all zones.

    The average climate is the only obligatory one.

    Pdesign = thermal load at the standard design

    temperature T design.

    I II

    626/2011

    A B C D E F G

    A B C D E F G

    A++++

    A+++

    A++

    A+

    A

    B

    C

    D

    E

    F

    G

    A++++

    A+++

    A++

    A+

    A

    B

    C

    D

    E

    F

    G

    A++++

    A+++

    A++

    A+

    A

    B

    C

    D

    E

    F

    G

    A++++

    A+++

    A++

    A+

    A

    B

    C

    D

    E

    F

    G

    ZYdB

    ZYdB

    ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI

    kW

    SCOP

    kWh/annum

    XY,ZX,YXY

    kW

    SEER

    kWh/annum

    XY,ZX,YXY

    XY,ZX,YXY

    XY,ZX,YXY

    SEER SCOP

  • Technology

    10

    Staging Unit A Staging Unit B

    Technology

    RAC Catalogue 2015 - Air Conditioning

    H-LINK Adapter: PSC-6RAD for centralised supervision of Room Air Conditioners

    All indoor units can be connected with the H-Link adapter (PSC-6RAD) in a single bus according to a communication protocol developed by Hitachi. This accessory makes residential units compatible with systems in the commercial, servi-ce industry and industrial range. The basic functions (On/Off, operation mode, set temperature, etc.) are programmable via the H-Link central controller.

    Compatibility with Somfy through RACInterface Somfy TaHoma® (SPX-TAG01)

    Through interface SPX TAG01 Hitachi RAC units are compatible with Somfy TaHoma® solution. In this way it is possible to control RAC

    and heat pumps units remotely via smartphone, tablet and PCs. Please contact Hitachi or Somfy for further details.

    Accessories and connettivity

    Compatibility MyHOME Bticino systemthrough RAC Interfaces HC-A(8/64)MBand PSC-6RAD

    Through interfaces HC-A(8/64)MB and PSC-6RAD Hitachi RAC units are compatible with MyHOME Bticino solution. In this way it is possible to control RAC units remotely via smartphone, tablet

    and PCs. This is very useful for Hotels and Residential applications. Please contact Hitachi or Bticino for further details.

  • RAC Residential

    11RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

    Clean contact kit (SPX-WDC1/2/3/4)

    A clean contact kit is available for all indoor units to enable/disable remote operation. Typical applications are the window contact (the unit is turned off when a win-dow is opened in the room so as not to waste energy) or the electronic key (the unit is turned off when the badge electronic key is removed from its slot).

    ID Switch

    When two indoor units are installed close to each other in the same room, the infra-red frequency on the remote controller can be differentiated, to prevent mixing the si-gnals controlling them.

    ON OFF

    Accessories and connettivity

    Distributor of signal(SPX-DST1 + SPX-WDST8M)The optional distributor SPX-DST1 can be used together with the remote controller when there is a need to centralise the control of multiple indoor units using only a single wi-red remote controller.

    A single distributor could be connected fur-ther to 3 separate distributors so that up to 13 units of indoor could be controlled by a single wired remote controller.

    For each connected unit one cable SPX-WDST8M (length of 8m) shall be connected.

    First connection

    4 INDOOR UNITS

    4 INDOOR UNITS

    4 INDOOR UNITS

    INDOOR UNIT

    MAX 13 UNITS CAN BE CONNECTED

    WIRED REMOTE CONTROLLER

    DISTRIBUTOR DISTRIBUTOR

    DISTRIBUTOR

    Second connection

    DISTRIBUTOR

  • Technology

    12

    Staging Unit A Staging Unit B

    Technology

    RAC Catalogue 2015 - Air Conditioning

    The new infra-red remote controller, available for a large number of models in the residential range, includes a host of functions to suit your lifestyle and assure the utmost comfort in your home. Its neat and essential design inspired by mini-mal and elegant aesthetics perfectly matches our air conditioners.

    The new infrared remote controller is equipped with a 7-day timer to suit your utilisation needs.

    Up to 6 on/off settings may be programmed for each day of the week, from Monday to Sunday.

    Up to 2 programs may be stored on the remote controller, for instance one valid in summer and the other in winter.

    The table below provides a programming example.

    All the information on your air conditioner’s operation and condition are cle arly laid out on the large LCD display and the pictograms on the function keys make programming easy.

    A built-in sensor instantly measures your room temperature in any position

    The new infrared remote controller has a variety of available features

    MON TUE WED THU FRI SAT SUN

    04:00 ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C

    06:00 ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C

    Switching on at the weekend

    08:00 OFF OFF OFF OFF OFF

    Switching off during working hours

    10:00 ON 18°C

    12:00 Decrease temperature during

    daytime14:00

    16:00

    18:00 ON 20°C

    20:00 ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C Increase temperature after sunsetSwitch on before getting home

    22:00 ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C

    Decrease temperature when going to bed

    24:00 OFF OFF OFF OFF OFF OFF OFF

    Switch off during the night

  • RAC Residential

    13RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

    Remote controller functions

    POWERFUL MODE The system works at maximum power in heating or cooling mode for 20 minutes in order to meet the demand for comfort in the shortest possible time. When the 20 minutes have elapsed the system automatically returns to the initial condition.

    LEAVE HOME When leaving home for a long period of time in winter, this function prevents the rooms from getting too cold (below 10°C). The duration of the LEAVE HOME function may be set for the desired length of time. When the set pe-riod has expired, the unit goes back to operating in the previously set mode.

    INFO Three different parameters may be displayed with the INFO button.

    1. Room temperature: the thermistor fi tted in the remote controller lets you view the room temperature on the display.

    2. Electrical consumption display: the monthly electrical consumption (current & previous month) may be displayed.

    3. Malfunctioning self-diagnosis: in the event of failure, the LCD remote controller displays the error code for easier maintenance.

    SILENT MODEWith the silent mode the sound level of the indoor unit may be lowered with just one touch by changing the fan speed.

    CLEANINGThanks to this feature the indoor unit will always keep clean and mould growth may be prevented after cooling operation by means of the evapora-tor’s drying action.

    SLEEP TIMERThe countdown timer may be set up to 7 hours’ duration. The ability to adjust temperature (±2°C) and lower fan speed assures comfortable sleep and con-siderable energy savings.

    ECO MODEIt allows you to keep electricity consumption in checkwhile always assuring fully effi cient operation.

    WIRED REMOTE CONTROLLERFor all RAC indoor units the optional wired remote controller is available:

    SPX-RCDB (for all indoor units except ducted ones)

    SPX-RCDA (only for ducted units)

    Some functions of the IR remote controller are not available for the wired remote controller, but it is always possible to activate them from IR remote controller even if the wired remote controller is installed.

    SPX-RCDASPX-RCDB

  • RAC Mono

    14

    Staging Unit A Staging Unit B

    RAC Mono

    RAC Catalogue 2015 - Air Conditioning

  • High seasonal effi ciency Extremely low Noise Levels

    Several models and capacities available Both summer and winter mode available

    A wide choice of units is available, suitable for both classical and modern environments, designed for the maximum comfort in terms of performance and indoor air quality,

    guaranteeing the maximum energy saving.

    RAC Mono

    PAM DC INVERTER AIR TO AIR HEAT PUMP UNITS FOR SINGLE ENVIRONMENT

    RAK 25PSBINDOOR UNITS example:

    What type ofair conditioner?RAK = wallRAF = floorRAI = 4-way cassetteRAD = ductable

    What coolingcapacity?XW = X,Y kW

    What type ofcombination?P = only mono-splitQ = only multi-splitR = mono and multi-split

    What family ofproducts?

    What seriesof products?A = series 1B = series 2

    What seriesof products?A = series 1B = series 2

    What type ofapplication?W = wallF = floorC = 4-way cassetteD = ductableN = universal

    What coolingcapacity?XW = X,Y kW

    What type ofcombination?RAC = only mono-splitRAM = only multi-split

    OUTDOOR UNITS example:

    S = PremiumX = Cut Out / AkebonoP = PerformanceE = Eco Comfort

    What family ofproducts?S = PremiumX = Cut Out / AkebonoP = PerformanceE = Eco Comfort

    RAC 25WSB

    RAC Residential

    15RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • RAK 18~25~35 PSB

    RAC Mono

    Exceptional seasonal efficiency the air conditioner features exceptional efficiency levels both in cooling and heating mode.

    Exceptional efficiency in heating mode thanks to its exceptional technical features, efficiency in heating mode is aaured up to -20°C and thermal capacity remains unchanged with respect to the nominal value up to -15°C.

    Eco sensor the motion sensors built into the indoor unit assure a good balance between the desired comfort and energy savings.

    Comfort airflow always thanks to the motion sensors, you may opt whether to aim the air flow away or at the user

    Quiet only 22 dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps.

    Stainless clean all inner surfaces of the air conditioner are constructed in stainless steel to assure the utmost cleanliness of the treated air, reducing the proliferation of pathogens. Thanks to this material, the air conditioner stays clean for a great many years.

    Filter clean just press a key on the remote controller, and a brush-fitted robotic arm located on the prefilters automatically cleans the indoor unit.

    Clean feature the evaporator is dried to prevent mould forma- tion.

    7-day timer 6 on/off settings for every day of the week, two storable programs (summer/winter).

    Leave home the feature lets you set a minimum hold temperature (10°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set Ideal for holiday homes!

    Info key room temperature reading, power consumption display, alarm signals.

    Vertical / horizontal swing the air flow is vertically and horizontally orientable from the remote controller thanks to the motorised flaps.

    PREMIUM Wall RAK-PSB

    PAM DC Inverter Split Heat Pump

    ION MIST

    ionised water mist particles invisible to the human eye released into the room by an ionised mist device are able to significantly reduce the concentration of bacteria, fungi and pollen in the air.

    +

    ION MIST device integrated in the indoor unit.

    16

    Staging Unit A Staging Unit B

    RAC Mono

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    +43-10

    +21-20

    Outdoor unit Unit of meas. RAC-18WSB RAC-25WSB RAC-35WSB

    Nominal cooling capacity (min - max) kW 1.8 (0.5 - 2.8) 2.5 (0.5 - 3.4) 3.5 (0.5 - 4.1)

    Nominal heating capacity (min - max) kW 2.3 (0.6 -4.8) 3.2 (0.6 -5.8) 4.0 (0.6 - 6.6)

    Nominal cooling power input (min - max) kW 0.300 (0.070-0.880) 0.470 (0.070-0.960) 0.805 (0.070-1.350)

    Nominal heating power input (min - max) kW 0.375 (0.065-1.620) 0.570 (0.065-2.250) 0.790 (0.065-2.450)

    EER / COP 6.00/6.13 5.32/5.61 4.35/5.06

    SEER / SCOP average climate 7.41/4.60 8.50/4.68 8.50/4.72

    Energy class (SEER/SCOP) A++/A++ A+++/A++ A+++/A++

    Cooling sound pressure level dB(A) 46 48 49

    Heating sound pressure level dB(A) 46 48 49

    Sound power - Indoor/Outdoor dB(A) 60 62 63

    Dimensions (H x L x D) mm 600x792x299 600x792x299 600x792x299

    Weight kg 40 40 40

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4” / 1/2” 1/4” / 1/2” 1/4” / 1/2”

    Minimum piping length m 3 3 3

    Max piping length / max lift m 20 / 10 20 / 10 20 / 10

    Max pre-charge length / Amount of additional refrigerant

    m / g/m 20 / - 20 / - 20 / -

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43

    °C -20~21 -20~21 -20~21

    Refrigerant R410A R410A R410A

    Indoor unit Unit of meas. RAK-18PSB RAK-25PSB RAK-35PSB

    Cooling sound pressure level (SL / L / M / H) dB(A) 22/28/34/40 22/28/34/42 23/28/34/44

    Heating sound pressure level (SL / L / M / H) dB(A) 22/30/34/41 22/30/34/42 23/30/34/44

    Sound power dB(A) 54 56 58

    Cooling air fl ow rate (SL / L / M / H) m3/h 260/300/420/ 470 260/320/420/510 270/320/420/520

    Heating air fl ow rate (SL / L / M / H) m3/h 260/300/420/540 260/370/520/600 270/410/520/610

    Dimensions (H x L x D) mm 295x798x258 295x798x258 295x798x258

    Weight kg 12 12 12

    Piping diameter (Liq / Gas) inch 1/4" / 1/2" 1/4" / 1/2" 1/4" / 1/2"

    Condensate drain diameter (ext) mm 16 16 16

    Remote controller (standard, optional)Standard RAR-5W1 RAR-5W1 RAR-5W1

    Optional SPX-RCDB SPX-RCDB SPX-RCDB

    Filter Optional Wasabi SPX-CFH22 Wasabi SPX-CFH22 Wasabi SPX-CFH22

    Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5

    Standard Pre-fi lter Stainless Steel Micro Mesh Stainless Steel Micro Mesh Stainless Steel Micro Mesh

    (1) with motion sensor and presence sensor

    (1)

    17RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • RAC Mono

    RAK 25~35~50RXB

    Elegant design a new range whose minimal design features are enhanced by high quality materials.

    Eco sensor the motion sensor built into the indoor unit assures a good balance between the desired comfort and energy savings.

    Wasabi Nano Titanium the WASABI NANO TITANIUM air filter supplied guarantees the high quality of the air you breathe in your room.

    Stainless clean the inner surface of the air flow outlet and prefilters are constructed in stainless steel to assure the utmost cleanliness of the treated air, reducing the proliferation of pathogens. Thanks to this material, the air conditioner stays clean for a great many years.

    Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode.

    Heating at low temperatures guaranteed performance in heating mode up to -15°C.

    Super quiet only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps.

    Vertical / Horizontal Swing the air flow is vertically and horizontally orientable from the remote controller thanks to the motorised flaps.

    7-day timer 6 on/off settings for every day of the week, two storable programs (summer/winter).

    Leave Home the feature lets you set a minimum hold temperature (10°C-16°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes!

    Info key room temperature reading, power consumption display, alarm signal.

    Clean function the evaporator is dried to prevent mould formation.

    AKEBONO Wall RAK-RXB

    PAM DC Inverter Split Heat Pump

    18

    Staging Unit A Staging Unit B

    RAC Mono

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    +43-10

    +21-15

    Outdoor unit Unit of meas. RAC-25WXB RAC-35WXB RAC-50WXB

    Nominal cooling capacity (min - max) kW 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (1.90- 5.20)

    Nominal heating capacity (min - max) kW 3.20 (0.90 - 4.20) 4.00 (0.90- 4.80) 5.80 (2.2- 7.00)

    Nominal cooling power input (min - max) kW 0.545 (0.25 - 1.22) 0.910 (0.25 - 1.40) 1.560 (0.50 - 2.10)

    Nominal heating power input (min - max) kW 0.700 (0.25 - 1.20) 0.955 (0.25 - 1.60) 1.560 (0.50 - 2.70)

    EER / COP 4.59/4.57 3.85/4.19 3.21/3.72

    SEER / SCOP average climate 8.50/4.70 8.50/4.72 7.20/4.50

    Energy class (SEER/SCOP) A+++/A++ A+++/A++ A++/A+

    Cooling sound pressure level dB(A) 46 47 51

    Heating sound pressure level dB(A) 47 49 51

    Sound power - Indoor/Outdoor dB(A) 60 61 65

    Dimensions (H x L x D) mm 548×750×288 548×750×288 736×800×350

    Weight kg 34 34 49,5

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Minimum piping length m 3 3 3

    Max piping length / max lift m 20 / 10 20 / 10 30 / 10

    Max pre-charge length / Amount of additional refrigerant

    m / g/m 20/- 20/- 30/-

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A

    Indoor unit Unit of meas. RAK-25RXB RAK-35RXB RAK-50RXB

    Cooling sound pressure level (SL / L / M / H) dB(A) 20/26/32/40 22/29/35/42 25/31/39/47

    Heating sound pressure level (SL / L / M / H) dB(A) 20/27/33/40 22/30/35/42 25/31/39/48

    Sound power dB(A) 55 60 60

    Cooling air fl ow rate (SL / L / M / H) m3/h 300/330/510/560 320/340/430/580 350/400/580/720

    Heating air fl ow rate (SL / L / M / H) m3/h 290/370/560/610 310/360/480/630 350/420/620/800

    Dimensions (H x L x D) mm 295 x 900 x 210 295 x 900 x 210 295 x 900 x 210

    Weight kg 11 11 11

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter (ext) mm 16 16 16mm

    Remote controller (standard, optional)Standard RAR-6N1 RAR-6N1 RAR-6N1

    Optional SPX-RCDB SPX-RCDB SPX-RCDB

    Filter Optional Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22

    Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5

    Standard Pre-fi lter Stainless Steel Stainless Steel Stainless Steel

    (1) with presence sensor

    SAME INDOOR UNITS COMPATIBLEWITH MONO/MULTI OUTDOOR

    (1)

    19RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • RAC Mono

    PERFORMANCE Wall RAK-RPB / RAK-PPA

    PAM DC InverterSplit Heat Pump

    RAK 60PPA RAK 70PPA

    RAK 18~25RPB

    RAK 35~50RPB

    Wide range available in 6 power levels from 1,8kW to 7kW in cooling mode to adapt to a wide range of different needs.

    Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode.

    Heating at low temperatures guaranteed performance in heating up to -15°C.

    Wasabi Nano Titanium the WASABI NANO TITANIUM air filter supplied guarantees the high quality of the air you breathe in your room.

    Vertical / Horizontal Swing the air flow is vertically and horizontally orientable from the remote controller thanks to the motorised flaps.

    Super silenzioso only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps.

    7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter).

    Leave home the feature lets you set a minimum hold temperature (10°C-16°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes!

    Info key room temperature reading, power consumption display, alarm signal.

    Clean function the evaporator is dried to prevent mould formation.

    20

    Staging Unit A Staging Unit B

    RAC Mono

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    +43-10

    +21-15

    Outdoor unit Unit of meas. RAC-18WPB RAC-25WPB RAC-35WPB RAC-50WPB RAC-60WPA RAC-70WPA

    Nominal cooling capacity (min - max) kW 2.00 (0.90 - 2.50) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (1.90- 5.20) 6.10 (0.9-6.5) 7.00 (1.5-8.00)

    Nominal heating capacity (min - max) kW 2.50 (0.90 - 3.20) 3.40 (0.90- 4.40) 4.20 (0.90- 5.00) 6.00 (2.2- 7.30) 6.80 (0.9-8.5) 8.00 (1.5-9.2)

    Nominal cooling power input (min - max) kW 0.55(0.25 - 1.01) 0.70 (0.25 - 1.29) 1.090 (0.25 - 1.46) 1.560 (0.50 - 2.10) 1.85 (0.155-2.300) 2.17 (0.200-2.820)

    Nominal heating power input (min - max) kW 0.58 (0.25 - 0.97) 0.88 (0.25 - 1.25) 1.100 (0.25 - 1.70) 1.660 (0.50 - 2.75) 1.88 (0.120-2.550) 2.2 (0.200-2.970)

    EER / COP 3.64/4.31 3.57/3.86 3.21/3.82 3.21/3.61 3.30 /3.62 3.23/3.64

    SEER / SCOP average climate 7.0/4.30 7.60/4.40 7.20/4.60 7.20/4.41 6.0/4.0 6.8/4.4

    Energy class (SEER/SCOP) A++/A+ A++/A+ A++A++ A++/A+ A+/A+ A++/A+

    Cooling sound pressure level dB(A) 46 48 49 51 50 52

    Heating sound pressure level dB(A) 47 49 50 51 53 54

    Sound power - Indoor/Outdoor dB(A) 60 62 63 65 66 67

    Dimensions (H x L x D) mm 530x660 x278 530x660 x278 548×750×288 600x792x299 650x850x298 800x850x298

    Weight kg 27,5 27,5 34 40 45 55

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch. 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8"

    Minimum piping length m 3 3 3 3 3 3

    Max piping length / max lift m 20 / 10 20 / 10 20 / 10 20 / 10 30 / 20 30 / 20

    Max pre-charge length / Amount of additional refrigerant

    m / g/m 20/- 20/- 20/- 20/- 30 / - 30 / -

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43 -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21 -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A R410A R410A R410A

    Indoor unit Unit of meas. RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB RAK-60PPA RAK-70PPA

    Cooling SPL (SL / L / M / H) dB(A) 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 25/28/39/46 30/33/42/48 30/33/42/47

    Heating SPL (SL / L / M / H) dB(A) 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 27/31/39/46 33/34/42/49 30/33/42/47

    Sound power dB(A) 51 54 57 60 63 61

    Cooling air fl ow rate (SL / L / M / H) m3/h 312/350/400/440 333/370/430/510 353/420/485/680 353/410/540/750 480/540/690/930 510/630/870/1020

    Heating air fl ow rate (SL / L / M / H) m3/h 312 / 350 / 420 / 480 333 / 400 / 500/ 570 363 / 480 / 570/ 780 380/500/610/820 480/510/720/1050 510/630/870/1080

    Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 295 x 900 x 230 295 x 900 x 230 295x1030x207 333x1150x245

    Weight kg 7,5 7,5 10 10 12 15

    Piping diameter (Liq / Gas) inch. 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8"

    Condensate drain diameter (ext) mm 16 16 16 16 16 16

    Remote controller(standard, optional)

    Standard RAR-6N2 RAR-6N2 RAR-6N1 RAR-6N1 RAR-5E2 RAR-5E1

    Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB

    Filter Standard Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-NTW1 Wasabi / SPX-NTW2

    Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5 48x243x5 35x270x5 35x280x5

    Pre-fi lter Standard WASHABLE WASHABLE WASHABLE WASHABLE WASHABLE WASHABLE

    Optional Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S /SPX-SPF7 Stainless S /SPX-SPF7 Stainless S/ SPX-SPF3 Stainless S/ SPX-SPF4

    (1) without sensor(2) for RAK-18RPB, RAK-25RPB, RAK-35RPB, RAK-50RPB

    (3) for RAK-60PPA, RAK-70PPA(4) only for RAK-35RPB, RAK-50RPB, RAK-70PPA

    SAME INDOOR UNITS COMPATIBLEWITH MONO/MULTI OUTDOOR

    (1) (2) (3) (4)

    21RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • RAC Mono

    RAK 18~25~35~50PEB

    Seasonal efficiency the air conditioner features good seasonal efficiencies levels both in cooling and heating mode

    Super quiet Only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps.

    12h Timer Available on the remote controller for convenient daily programming.

    Heating at low temperatures guaranteed efficiency in heating mode up to -15°C.

    Leave Home the feature lets you set a minimum hold temperature (10°C) in heating mode for the periods you are away either on holiday or businness.

    Eco and Powerful functions you may opt whether to operate the air conditioner at very low consumption or at maximum power to reach the desired temperature quickly.

    ECO COMFORT Wall RAK-PEB

    PAM DC Inverter Split Heat Pump

    22

    Staging Unit A Staging Unit B

    RAC Mono

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    +43-10

    +21-15

    Outdoor unit Unit of meas. RAC-18WEB RAC-25WEB RAC-35WEB RAC-50WEB

    Nominal cooling capacity (min - max) kW 2.00 (0.90 - 2.50) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (0.90- 5.20)

    Nominal heating capacity (min - max) kW 2.50 (0.90 - 3.20) 3.40 (0.90- 4.40) 4.20 (0.90- 5.00) 6.00 (2.2- 7.30)

    Nominal cooling power input (min - max) kW 0.58 (0.25-1.01) 0.70 (0.25 -1.29) 1.090 (0.25 - 1.46) 1.560 (0.50 - 2.10)

    Nominal heating power input (min - max) kW 0.62 (0.25-0.97) 0.88 (0.25 - 1.25) 1.100 (0.25 - 1.70) 1.660 (0.50 - 2.75)

    EER / COP 3.45/4.03 3.57/3.86 3.21/3.82 3.21/3.61

    SEER / SCOP average climate 5.80/3.80 5.80/3.80 5.85/3.80 5.88/3.80

    Energy class (SEER/SCOP) A+/A A+/A A+/A A+/A

    Cooling sound pressure level dB(A) 46 48 49 51

    Heating sound pressure level dB(A) 47 49 50 51

    Sound power - Indoor/Outdoor dB(A) 60 62 63 65

    Dimensions (H x L x D) mm 530x660 x278 530x660 x278 530x660 x278 600x792x299

    Weight kg 27,5 27,5 27,5 40

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Minimum piping length m 3 3 3 3

    Max piping length / max lift m 20 / 10 20 / 10 20 / 10 20 / 10

    Max pre-charge length / Amount of additional refrigerant

    m / g/m 20/- 20/- 20/- 20/-

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A R410A

    Indoor unit Unit of meas. RAK-18PEB RAK-25PEB RAK-35PEB RAK-50PEB

    Cooling sound pressure level (SL / L / M / H) dB(A) 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 28 / 30 / 40 /46

    Heating sound pressure level (SL / L / M / H) dB(A) 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 25 /30/ 39 /47

    Sound power dB(A) 51 54 57 60

    Cooling air fl ow rate (SL / L / M / H) m3/h 312/350/400/440 333/370/430/510 333/400/485/600 333/450/600/700

    Heating air fl ow rate (SL / L / M / H) m3/h 312 / 350 / 420 / 480 333 / 400 / 500/ 570 333 / 520 / 550/ 660 433 / 510 / 650/ 770

    Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218

    Weight kg 7,5 7,5 7,5 8

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter (ext) mm 16 16 16 16

    Remote controller (standard, optional)Standard RAR-5F1 RAR-5F1 RAR-5F1 RAR-5F1

    Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB

    Filter Optional Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22

    Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5 48x243x5

    Pre-fi lterStandard WASHABLE WASHABLE WASHABLE WASHABLE

    Optional Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S/SPX-SPF6

    (1) without sensor

    (1)

    23RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • AKEBONO Floor RAF-RXB

    RAC Mono

    PAM DC Inverter Split Heat Pump

    RAF-25-35-50RXB

    Elegant design designed to combine comfort and functionality with refined and streamlined aesthetics, it can also be installed suspended above the floor without the white stand.

    Extended air flow The airflow power can be increased to reach the furthest corners of the room.

    Nano Titanium the NANO TITANIUM air filter supplied guarantees high quality of the air you breathe in your room.

    Extremely high seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode.

    Heating at low temperatures guaranteed performance in heating mode up to -15°C.

    Super quiet Only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps.

    7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter).

    Leave Home the feature lets you set a minimum hold temperature (10°C-16°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes!

    Info key room temperature reading, power consumption display, alarm signal.

    Clean function the evaporator is dried to prevent mould formation.

    24

    Staging Unit A Staging Unit B

    RAC Mono

    RAC Catalogue 2015 - Air Conditioning

  • +43-10

    +21-15

    RAC Residential

    Outdoor unit Unit of meas. RAC-25FXB RAC-35FXB RAC-50FXB

    Nominal cooling capacity (min - max) kW 2.50 (0.90 - 3.10) 3.5(0.9-4.0) 5.0 (0.9-5.2)

    Nominal heating capacity (min - max) kW 3.40 (0.90- 4.40) 4.5(0.9-5.0) 6.0 (0.9-8.1)

    Nominal cooling power input (min - max) kW 0.580 (0.155 - 1.180) 1.020(0.155-1.380) 1.560(0.500-2.100)

    Nominal heating power input (min - max) kW 0.790(0.115 - 1.120) 1.220(0.115-1.350) 1.600(0.500-2.700)

    EER / COP 4.31/4.30 3.43/3.69 3.21/3.75

    SEER / SCOP average climate 6.38/4.24 6.39/4.14 5.97/4.15

    Energy class (SEER/SCOP) A++/A+ A++/A+ A+/A+

    Cooling sound pressure level dB(A) 45 46 50

    Heating sound pressure level dB(A) 47 48 52

    Sound power - Indoor/Outdoor dB(A) 62 63 65

    Dimensions (H x L x D) mm 548×750×288 548×750×288 736×800×350

    Weight kg 31,5 31,5 49,5

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Minimum piping length m 3 3 3

    Max piping length / max lift m 20 / 10 20 / 10 30 / 10

    Max pre-charge length / Amount of additional refrigerant

    m / g/m 20/- 20/- 30/-

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A

    Indoor unit Unit of meas. RAF-25RXB RAF-35RXB RAF-50RXB

    Cooling sound pressure level (SL / L / M / H) dB(A) 20/26 / 31 /38 20/26/31/39 22/29/36/43

    Heating sound pressure level (SL / L / M / H) dB(A) 20/26 / 31 /38 20/26/31/39 22/29/36/44

    Sound power dB(A) 55 56 59

    Cooling air fl ow rate (SL / L / M / H) m3/h 270 / 390 / 510 / 630 270/390/510/660 300/450/540/720

    Heating air fl ow rate (SL / L / M / H) m3/h 300 / 420 / 540/ 660 300/420/540/690 330/480/570/750

    Dimensions (H x L x D) mm 590 x 750 x 215 590 x 750 x 215 590 x 750 x 215

    Weight kg 15 15 15

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter (ext) mm 16 16 16

    Remote controller (standard, optional)Standard RAR-6N4 RAR-6N4 RAR-6N4

    Optional SPX-RCDB SPX-RCDB SPX-RCDB

    Filter Optional Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15

    Standard fi lter dimensions (H x L x D) mm 48x243x8 48x243x8 48x243x8

    Standard Pre-fi lter Stainless Steel Stainless Steel Stainless Steel

    (1) without sensor

    SAME INDOOR UNITS COMPATIBLEWITH MONO/MULTI OUTDOOR

    (1)

    25RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • RAF 25~35~50 RPA

    PERFORMANCE Floor RAF-RPA

    PAM DC Inverter Split Heat Pump

    RAF 25~35~50 RPA

    NANO TITANIUM the NANO TITANIUM air filter supplied guarantees high quality of the air you breathe in your room.

    Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode.

    Heating at low temperatures guaranteed performance in heating mode up to -15°C.

    Quiet only 23dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps.

    7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter).

    Leave Home the feature lets you set a minimum hold temperature (10°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes!

    Info key room temperature reading, power consumption display, alarm signal.

    Clean function the evaporator is dried to prevent mould formation.

    RAC Mono

    26

    Staging Unit A Staging Unit B

    RAC Mono

    RAC Catalogue 2015 - Air Conditioning

  • +43-10

    +21-15

    RAC Residential

    Outdoor unit Unit of meas. RAC-25FPA RAC-35FPA RAC-50FPA

    Nominal cooling capacity (min - max) kW 2.50 (0.90 - 3.10) 3.50 (1.10 - 4.20) 5.00 (1.90 - 5.20)

    Nominal heating capacity (min - max) kW 3.40 (0.90 - 4.40) 4.20 (1.10 - 5.20) 6.00 (2.20 - 7.30)

    Nominal cooling power input (min - max) kW 0.67 (0.25 - 1.29) 0.94 (0.25 - 1.40) 1.51 (0.50 - 2.10)

    Nominal heating power input (min - max) kW 0.85 (0.25 - 1.25) 1.05 (0.25 - 1.80) 1.66 (0.50 - 2.70)

    EER / COP 3.73/4.00 3.72 / 4.00 3.31 / 3.61

    SEER / SCOP average climate 5.8/4.3 6.0/4.3 5.9/4.0

    Energy class (SEER/SCOP) A+/A+ A+/A+ A+/A+

    Cooling sound pressure level dB(A) 47 48 51

    Heating sound pressure level dB(A) 49 49 52

    Sound power - Indoor/Outdoor dB(A) 61 62 65

    Dimensions (H x L x D) mm 548x750x288 548x750x288 600x792x299

    Weight kg 31 35 40

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4” - 3/8” 1/4” - 3/8” 1/4” - 1/2”

    Minimum piping length m 5 5 5

    Max piping length / max lift m 20 / 10 20 / 10 20 / 10

    Max pre-charge length / Amount of additional refrigerant

    m / g /m 20/- 20/- 20/-

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A

    Indoor unit Unit of meas. RAF-25RPA RAF-35RPA RAF-50RPA

    Cooling sound pressure level (SL / L / M / H) dB(A) 23/26/32/40 25/29/35/42 25/30/37/46

    Heating sound pressure level (SL / L / M / H) dB(A) 23/27/33/40 26/30/35/42 25/30/37/47

    Sound power dB(A) 54 56 60

    Cooling air fl ow rate (SL / L / M / H) m3/h 378/462/540 400/485/600 430/530/650

    Heating air fl ow rate (SL / L / M / H) m3/h 408/498/600 440/525/600 470/570/720

    Dimensions (H x L x D) mm 600x760x235 600x760x235 600x760x235

    Weight kg 14 14 14

    Piping diameter (Liq / Gas) inch 1/4” - 3/8” 1/4” - 3/8” 1/4” - 1/2”

    Condensate drain diameter (ext) mm 16 16 16

    Remote controller (standard, optional)Standard RAR-5E2 RAR-5E2 RAR-5E2

    Optional SPX-RCDB SPX-RCDB SPX-RCDB

    Filter Optional Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15

    Standard fi lter dimensions (H x L x D) mm 48x243x8 48x243x8 48x243x8

    Standard Pre-fi lter Stainless steel Stainless steel Stainless steel

    (1) without sensor

    (1)

    27RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • Mono Split

    RAD 25~35~50 RPA

    Head rise selector depending on whether ductless or linear ducting (up to 4m) installation is opted for, fan head rise may be adjusted via a suitable selector on the electronic board.

    Optimised refrigerant connections for convenient installation the refrigerant connections are located at the rear of the unit to make installation easier. Ideal for above door installation!

    Seasonal efficiency the air conditioner features good seasonal efficiencies levels both in cooling and heating mode.

    Heating at low temperatures guaranteed performance in heating mode up to -15°C.

    Optional infra red or wired remote controller the preferred type of controller may be selected (IR infra red or wired) on purchase. The IR controller includes a higher number of features.

    7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). (*with IR controller only)

    Leave Home the feature lets you set a minimum hold temperature (10°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! (*with IR controller only).

    Info key room temperature reading, power consumption display, alarm signal. (*with IR controller only).

    Clean function the evaporator is dried to prevent mould formation.

    DUCTLow Static Pressure RAD-RPA

    PAM DC Inverter Split Heat Pump

    BUILT-IN CONDENSATE DRAIN PUMP

    This unit is fitted with an internal drain pump to remove the condensate water which accumulates in the drip pan during operation. A float monitors the water level and automatically actuates the pump when required.

    +

    28

    Staging Unit A Staging Unit B

    Mono Split

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    +43-10

    +21-15

    Outdoor unit Unit of meas. RAC-25NPA RAC-35NPA RAC-50NPA

    Nominal cooling capacity (min - max) kW 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.6)

    Nominal heating capacity (min - max) kW 3.5 (0.9-5.5) 4.8 (0.9-6.6) 6.0 (0.9-7.5)

    Nominal cooling power input (min - max) kW 0.695 (0.155-1.050) 1.240 (0.155-1.280) 2.160 (0.155-2.700)

    Nominal heating power input (min - max) kW 0.970 (0.115-1.400) 1.700 (0.115-1.920) 2.300 (0.115-2.530)

    EER / COP 3.60 / 3.61 2.82 / 2.82 2.50 / 2.61

    SEER / SCOP average climate 5.1 / 3.8 5.1 / 3.8 4.7 / 3.8

    Energy class (SEER/SCOP) A / A A / A B / A

    Cooling sound pressure level dB(A) 46 47 50

    Heating sound pressure level dB(A) 46 49 52

    Sound power - Indoor/Outdoor dB(A) 65 65 65

    Dimensions (H x L x D) mm 570x750x280 570x750x280 650x850x298

    Weight kg 38 38 45

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Minimum piping length m 5 5 5

    Max piping length / max lift m 20 / 10 20 / 10 20 / 10

    Max pre-charge length / Amount of additional refrigerant

    m / g/m 20/- 20/- 20/-

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A

    Indoor unit Unit of meas. RAD-25RPA RAD-35RPA RAD-50RPA

    Cooling sound pressure level (SL / L / M / H) dB(A) 29/31/34/36 29/31/34/36 29/32/35/38

    Heating sound pressure level (SL / L / M / H) dB(A) 27/30/33/37 27/30/33/37 29/32/35/38

    Sound power dB(A) 57 57 58

    Cooling air fl ow rate (SL / L / M / H) m3/h 330/390/450/510 330/390/450/510 330/360/450/510

    Heating air fl ow rate (SL / L / M / H) m3/h 360/420/480/600 360/420/480/600 360/420/480/630

    Drain pump included yes yes yes

    Max. height available for drain pump cm 30 30 30

    Drain pump pressure lift cm 30 30 30

    Dimensions (H x L x D) mm 235x750x400 235x750x400 235x750x400

    Weight kg 16 16 16

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter (ext) mm 16 16 16

    Standard remote controller (standard, optional)Standard no no no

    Optional SPX-RCKA o SPX-RCDA SPX-RCKA o SPX-RCDA SPX-RCKA o SPX-RCDA

    Standard pre-fi lter WASHABLE WASHABLE WASHABLE

    (1) without sensor(2) with IR controller only

    (1) (2) (2) (2) (2) (2) (2)

    (2) (2) (2) (2)

    29RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • Mono Split

    RAD 50~60~70 PPA

    Selettore di prevalenza depending on whether ductless or ducted installation is opted for, fan head rise may be adjusted via a suitable selector on the electronic board. Three static pressure levels (30 / 50 / 80 Pa) may be selected. Ideal for very long ducting!

    Washable Pre-filter the unit is fitted with a complementary washable prefilter.

    Seasonal efficiency the air conditioner features good seasonal efficiencies levels both in cooling and heating mode.

    Heating at low temperatures guaranteed performance in heating mode up to -15°C.

    Optional infra red or wired remote controller the preferred type of controller may be selected (IR infra red or wired) on purchase. The IR controller includes a higher number of features.

    7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). (*with IR controller only)

    Leave Home the feature lets you set a minimum hold temperature (10°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! (*with IR controller only).

    Info key room temperature reading, power consumption display, alarm signal. (*with IR controller only).

    Clean function the evaporator is dried to prevent mould formation.

    PAM DC Inverter Split Heat Pump

    BUILT-IN CONDENSATE DRAIN PUMP

    This unit is fitted with an internal drain pump to remove the condensate water which accumulates in the drip pan during operation. A float monitors the water level and automatically actuates the pump when required.

    +

    DUCTMiddle Static Pressure RAD-PPA

    30

    Staging Unit A Staging Unit B

    Mono Split

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    +43-10

    +21-15

    Outdoor unit Unit of meas. RAC-50DPA RAC-60DPA RAC-70DPA

    Nominal cooling capacity (min - max) kW 5.0 (0.9-6.0) 6.0 (0.9-7.0) 7.1 (0.9-8.0)

    Nominal heating capacity (min - max) kW 6.0 (0.9-7.0) 7.3 (0.9-8.0) 8.0 (0.9-9.0)

    Nominal cooling power input (min - max) kW 1.4 (0.200-2.500) 1.87 (0.200-2.500) 2.53 (0.200-2.920)

    Nominal heating power input (min - max) kW 1.59 (0.200-2.200) 2.13 (0.200-2.600) 2.34 (0.200-3.100)

    EER / COP 3.57/3.77 3.21/3.43 2.81/3.42

    SEER / SCOP average climate 5.4/3.8 5.1/3.8 5.1/3.8

    Energy class (SEER/SCOP) A/A A/A A/A

    Cooling sound pressure level dB(A) 47 48 53

    Heating sound pressure level dB(A) 50 51 55

    Sound power - Indoor/Outdoor dB(A) 65 65 67

    Dimensions (H x L x D) mm 800x850x298 800x850x298 800x850x298

    Weight kg 51.5 55 55

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8"

    Minimum piping length m 5 5 5

    Max piping length / max lift m 30 / 20 30 / 20 30 / 20

    Max pre-charge length / Amount of additional refrigerant

    m / g/m 30/- 30/- 30/-

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A

    Indoor unit Unit of meas. RAD-50PPA RAD-60PPA RAD-70PPA

    Cooling sound pressure level (SL / L / M / H) dB(A) 28/30/32/34 28/30/32/34 28/30/32/35

    Heating sound pressure level (SL / L / M / H) dB(A) 29/31/33/35 29/31/33/35 29/31/33/36

    Sound power dB(A) 60 60 61

    Cooling air fl ow rate (SL / L / M / H) m3/h 618/660/780/900 618/660/780/900 618/660/780/960

    Heating air fl ow rate (SL / L / M / H) m3/h 618/660/780/900 618/660/780/900 618/660/780/960

    Drain pump included sì sì sì

    Max. height available for drain pump cm 50 50 50

    Drain pump pressure lift cm - - -

    Max static pressure with activated selector LSP / NSP / HSP

    Pa (m3/h) 30/50/80 30/50/80 30/50/80

    Dimensions (H x L x D) mm 270x900x720 270x900x720 270x900x720

    Weight kg 35 35 35

    Piping diameter (Liq / Gas) inch 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8"

    Condensate drain diameter (ext) mm 16 16 16

    Standard remote controller (standard, optional)Standard no no no

    Optional SPX-RCDA o SPX-RCKA SPX-RCDA o SPX-RCKA SPX-RCDA o SPX-RCKA

    Standard pre-fi lter WASHABLE WASHABLE WASHABLE

    (1) without senosr(2) with IR controller only

    (1) (2) (2) (2) (2) (2) (2)

    (2) (2) (2) (2)

    31RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • Mono Split

    Compact Design thanks to its compact design, the 60 x 60 cm cassette unit fits into a standard ceiling module, thus reducing installation work to the minimum.

    Flexibility of use The user may opt for 2, 3 or 4-way operation of automatic swing air outlets. Furthermore, when the unit is installed on high ceilings, air flow power may be increased by means of a switch.

    Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiencies levels both in cooling and heating mode.

    Heating at low temperatures guaranteed performance in heating mode up to -15°C.

    7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter).

    Leave Home the feature lets you set a minimum hold temperature (10°C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes!

    Info key room temperature reading, power consumption display, alarm signal.

    Clean function the evaporator is dried to prevent mould formation.

    PAM DC Inverter Split Heat Pump

    CASSETTE 4 Way RAI-RPA

    RAI 25~35~50 RPA + RAI - ECPP PANEL

    2-WAY 3-WAY 4-WAY

    BUILT-IN CONDENSATE DRAIN PUMP

    This unit is fitted with an internal drain pump to remove the condensate water which accumulates in the drip pan during operation. A float monitors the water level and automatically actuates the pump when required.

    +

    32

    Staging Unit A Staging Unit B

    Mono Split

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    +43-10

    +21-15

    Outdoor unit Unit of meas. RAC-25NPA RAC-35NPA RAC-50NPA

    Nominal cooling capacity (min - max) kW 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.2)

    Nominal heating capacity (min - max) kW 3.5 (0.9-5.0) 4.8 (0.9-6.6) 6.2 (0.9-7.6)

    Nominal cooling power input (min - max) kW 0.695 (0.155-1.050) 1.100 (0.155-1.280) 1.990 (0.155-2.200)

    Nominal heating power input (min - max) kW 0. 940 (0.155-1.400) 1.360 (0.115-1.920) 2.160 (0.155-2.700)

    EER / COP 3.60 / 3.72 3.18 / 3.53 2.51 / 2.87

    SEER / SCOP average climate 5.7 / 3.8 5.8 / 3.8 5.2 / 3.8

    Energy class (SEER/SCOP) A+ / A A+ / A A / A

    Cooling sound pressure level dB(A) 46 47 50

    Heating sound pressure level dB(A) 46 49 52

    Sound power - Indoor/Outdoor dB(A) 65 65 65

    Dimensions (H x L x D) mm 570x750x280 570x750x280 650x850x298

    Weight kg 38 38 45

    Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Minimum piping length m 5 5 5

    Max piping length / max lift m 20 / 10 20 / 10 20 / 10

    Max pre-charge length/Amount of additional refrigerant

    m / g/m 20/- 20/- 20/-

    Working range (cooling, heating)

    °C -10~43 -10~43 -10~43

    °C -15~21 -15~21 -15~21

    Refrigerant R410A R410A R410A

    Indoor unit Unit of meas. RAI-25RPA RAI-35RPA RAI-50RPA

    Cooling sound pressure level (SL / L / M / H) dB(A) 25/29/32/35 26/29/34/39 29/32/35/43

    Heating sound pressure level (SL / L / M / H) dB(A) 27/30/33/36 29/32/36/40 30/32/36/43

    Sound power dB(A) 50 58 58

    Cooling air fl ow rate (SL / L / M / H) m3/h 330/360/420/480 390/420/510/570 390/450/510/630

    Heating air fl ow rate (SL / L / M / H) m3/h 390/420/480/540 450/480/510/660 450/510/540/690

    Drain pump included sì sì sì

    Max. height available for drain pump cm 11,5 11,5 11,5

    Drain pump pressure lift cm 11,5 11,5 11,5

    Dimensions (H x L x D) mm 285x580x580 285x580x580 285x580x580

    Weight kg 20 20 20

    Panel weight kg 4 4 4

    Panel dimensions (H x L x D) mm 32x650x650 32x650x650 32x650x650

    Code of panel RAI-ECPP RAI-ECPP RAI-ECPP

    Panel colour (RAL) RAL 9010 RAL 9010 RAL 9010

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter (ext) mm 16 16 16

    Standard remote controller (standard, optional)Standard RAR-5E2 RAR-5E2 RAR-5E2

    Optional SPX-RCDB SPX-RCDB SPX-RCDB

    Filter Optional WASABI / SPX-NTW1 WASABI / SPX-NTW1 WASABI / SPX-NTW1

    Dimensions standard fi lter (H x L x D) mm 35x270x5 35x270x5 35x270x5

    Pre-fi ltro standard LAVABILE LAVABILE LAVABILE

    (1)

    (1) without sensor

    33RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • RAC Multi

    34

    Staging Unit A Staging Unit B

    RAC Multi

    RAC Catalogue 2015 - Air Conditioning

  • EFF IC IENT & FLEX IBLE

    High seasonal effi ciency Super silent units

    High fl exibility of installation Summer/Winter Mode

    Multizone Premium line: Available in several sizes

    with the possibility of connecting up to 6 indoor units to the same outdoor one.

    PAM DC INVERTER HEAT PUMPS FOR SEVERAL ENVIRONMENTS

    RAC MultiRAK 25RPBINDOOR UNITS example:

    What type ofair conditioner?RAK = wallRAF = floorRAI = 4-way cassetteRAD = ductable

    What coolingcapacity?XW = X,Y kW

    What type ofcombination?P = only mono-splitQ = only multi-splitR = mono and multi-split

    What family ofproducts?

    What seriesof products?B = series 2

    What seriesof products?B = series 2

    What type ofapplication?W = wallF = floorC = 4-way cassetteD = ductableN = universal

    What coolingcapacity?XW = X,Y kW

    What type ofcombination?RAC = only mono-splitRAM = only multi-split

    OUTDOOR UNITS example:

    P = Performance

    What family ofproducts?P = all Multi

    RAM 53NP3B

    How many connections?2,3,..,6 = 2,3,..,6 environments

    RAC Residential

    35RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • PAM DC InverterMultisplitHeat Pump

    Outdoor Units

    RAM 33NP2BRAM 40NP2B

    RAM 53NP2BRAM 53NP3B

    RAM 90NP5B RAM 110NP6BRAM 68NP3BRAM 70NP4B

    RAC Multizone Premium

    Outdoor unitUnit

    of meas.RAM-33NP2B RAM-40NP2B RAM-53NP2B RAM-53NP3B RAM-68NP3B RAM-70NP4B RAM-90NP5B RAM-110NP6B

    Min / Max number of connectible indoor units 2 2 2 2 / 3 2 / 3 2 / 4 2 / 5 2 / 3 (per ciclo refr.)

    Nominal Cooling Capacity (min - max) kW 3.3 (1.5-3.8) 4.0 (1.5-4.2) 5.3 (1.5-6.6) 5.3 (1.5-6.6) 6.8 (2.40-8.00) 7.0 (2.4-8.8) 8.5 (1.52-9.5) 10.6 (1.5-13.2)

    Nominal Heating Capacity (min - max) kW 4.0 (1.5-4.6) 5.2 (1.5-5.5) 6.8 (1.5-7.2) 6.8 (1.5-7.2) 8.5 (2.4-9.5) 8.5 (2.6-9.5) 11.0 (1.5-11.5) 13.6 (1.5-14.4)

    Nominal Cooling Power Input (min - max) kW 0.80 (0.20-1.05) 1.05 (0.20-1.15) 1.55 (0.20-1.66) 1.55 (0.20-1.68) 2.08 (0.46-2.96) 2.11 (0.46-3.20) 2.23 (0.20-3.85) 3.20 (0.20-3.50)

    Nominal Heating Power Input (min - max) kW 0.92 (0.20-1.50) 1.21 (0.20-1.50) 1.79 (0.20-2.01) 1.62 (0.20-1.86) 2.28 (0.43-2.60) 2.11 (0.48-3.12) 2.46 (0.20-3.85) 3.60 (0.40-3.72)

    EER / COP 4.13/4.35 3.81/4.30 3.42/3.80 3.42/4.20 3.27/3.73 3.32/4.03 3.81/4.47 3.31/3.78

    SEER / SCOP average climate 6.30/4.30 7.00/4.33 7.15/4.31 7.15/4.31 6.60/4.20 6.30/4.20 6.50/4.20 6.30/4.20

    Energy Class (SEER/SCOP) A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+

    Cooling sound pressure level dB(A) 48 49 50 50 50 50 53 55

    Heating sound pressure level dB(A) 50 51 51 51 53 53 56 56

    Sound Power - Indoor/Outdoor dB(A) 47/61 47/62 50/62 50/62 50/63 57/63 57/66 50/68

    Dimensions (H x L x D) mm 570x750x280 570x750x280 750x850x298 750x850x298 800x850x298 800x850x298 800x950x370 1450x855x308

    Weight kg 38 41 53 53 58 58 71 113

    Power supply V/Ph/Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz

    Piping diameter (Liq / Gas) inch 1/4” x 2 / 3/8” x 2 1/4” x 2 / 3/8” x 2 ( 1/4” x 2 / 3/8” x 2 ) ( 1/4” x 3 / 3/8” x 3 ) ( 1/4” x 3 / 3/8” x 3 ) ( 1/4” x 4 / 3/8” x 3 + 1/2” x 1) 1/4” x 5 / (3/8” x 3) + (1/2” x 2) ( 1/4” x 3 / 3/8” x 3 ) x 2

    Minimum piping length m 3 3 3 3 3 3 3 3

    Max piping length / max lift m 20 / 10 35 / 20 35 / 20 45 / 20 60 / 20 60 / 20 75 / 20 45/20 per ciclo refr.

    Max pre-charge length/Amount of additional refrigerant

    m / g/m 20/- 35/- 35/- 35/20 30/20 30/20 30/15 35/20

    Working range (cooling, heating)

    °C -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43

    °C -15 ~ 21 -15 ~ 21 -15 ~ 2 -15 ~ 21 -15 ~ 21 -15 ~ 21 -15 ~ 21 -15 ~ 21

    Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A

    RAM-33NP2BRAM-40NP2BRAM-53NP2BRAM-53NP3BRAM-68NP3BRAM-70NP4BRAM-90NP5B

    Specifications relating to the following combinations:

    RAK-15QPB + RAK-18RPBRAK-15QPB + RAK-25RPBRAK-18RPB + RAK-35RPBRAK-18RPB + RAK-35RPBRAK-18RPB + RAK-50RPBRAK-35RPB + RAK-35RPBRAK-35RPB + RAK-50RPB

    36

    Staging Unit A Staging Unit B

    RAC Multizone Premium

    RAC Catalogue 2015 - Air Conditioning

  • +43-10

    +21-15

    RAC Residential

    Outdoor unitUnit

    of meas.RAM-33NP2B RAM-40NP2B RAM-53NP2B RAM-53NP3B RAM-68NP3B RAM-70NP4B RAM-90NP5B RAM-110NP6B

    Min / Max number of connectible indoor units 2 2 2 2 / 3 2 / 3 2 / 4 2 / 5 2 / 3 (per ciclo refr.)

    Nominal Cooling Capacity (min - max) kW 3.3 (1.5-3.8) 4.0 (1.5-4.2) 5.3 (1.5-6.6) 5.3 (1.5-6.6) 6.8 (2.40-8.00) 7.0 (2.4-8.8) 8.5 (1.52-9.5) 10.6 (1.5-13.2)

    Nominal Heating Capacity (min - max) kW 4.0 (1.5-4.6) 5.2 (1.5-5.5) 6.8 (1.5-7.2) 6.8 (1.5-7.2) 8.5 (2.4-9.5) 8.5 (2.6-9.5) 11.0 (1.5-11.5) 13.6 (1.5-14.4)

    Nominal Cooling Power Input (min - max) kW 0.80 (0.20-1.05) 1.05 (0.20-1.15) 1.55 (0.20-1.66) 1.55 (0.20-1.68) 2.08 (0.46-2.96) 2.11 (0.46-3.20) 2.23 (0.20-3.85) 3.20 (0.20-3.50)

    Nominal Heating Power Input (min - max) kW 0.92 (0.20-1.50) 1.21 (0.20-1.50) 1.79 (0.20-2.01) 1.62 (0.20-1.86) 2.28 (0.43-2.60) 2.11 (0.48-3.12) 2.46 (0.20-3.85) 3.60 (0.40-3.72)

    EER / COP 4.13/4.35 3.81/4.30 3.42/3.80 3.42/4.20 3.27/3.73 3.32/4.03 3.81/4.47 3.31/3.78

    SEER / SCOP average climate 6.30/4.30 7.00/4.33 7.15/4.31 7.15/4.31 6.60/4.20 6.30/4.20 6.50/4.20 6.30/4.20

    Energy Class (SEER/SCOP) A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ A++/A+

    Cooling sound pressure level dB(A) 48 49 50 50 50 50 53 55

    Heating sound pressure level dB(A) 50 51 51 51 53 53 56 56

    Sound Power - Indoor/Outdoor dB(A) 47/61 47/62 50/62 50/62 50/63 57/63 57/66 50/68

    Dimensions (H x L x D) mm 570x750x280 570x750x280 750x850x298 750x850x298 800x850x298 800x850x298 800x950x370 1450x855x308

    Weight kg 38 41 53 53 58 58 71 113

    Power supply V/Ph/Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz

    Piping diameter (Liq / Gas) inch 1/4” x 2 / 3/8” x 2 1/4” x 2 / 3/8” x 2 ( 1/4” x 2 / 3/8” x 2 ) ( 1/4” x 3 / 3/8” x 3 ) ( 1/4” x 3 / 3/8” x 3 ) ( 1/4” x 4 / 3/8” x 3 + 1/2” x 1) 1/4” x 5 / (3/8” x 3) + (1/2” x 2) ( 1/4” x 3 / 3/8” x 3 ) x 2

    Minimum piping length m 3 3 3 3 3 3 3 3

    Max piping length / max lift m 20 / 10 35 / 20 35 / 20 45 / 20 60 / 20 60 / 20 75 / 20 45/20 per ciclo refr.

    Max pre-charge length/Amount of additional refrigerant

    m / g/m 20/- 35/- 35/- 35/20 30/20 30/20 30/15 35/20

    Working range (cooling, heating)

    °C -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43 -10 ~ 43

    °C -15 ~ 21 -15 ~ 21 -15 ~ 2 -15 ~ 21 -15 ~ 21 -15 ~ 21 -15 ~ 21 -15 ~ 21

    Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A

    COMBINATIONS

    OUTDOOR UNIT

    WALL FLOORDUCTABLE MEDIUM STATIC PRESSURE

    CASSETTE

    RAK-QXBRAK-RXB

    RAK-QPBRAK-RPB

    RAF-RXB RAD-QPB RAI-QPB

    18 25 35 50 15 18 25 35 50 25 35 50 18 25 35 50 25 35 50

    RAM-33NP2B x x x x x x x x x

    RAM-40NP2B x x x x x x x x x x x x x x

    RAM-53NP2B x x x x x x x x x x x x x x x x x x x

    RAM-53NP3B x x x x x x x x x x x x x x x x x x x

    RAM-68NP3B x x x x x x x x x x x x x x x x x x x

    RAM-70NP4B x x x x x x x x x x x x x x x x x x x

    RAM-90NP5B x x x x x x x x x x x x x x x x x x x

    RAM-110NP6B x x x x x x x x x x x x x x x x x x x

    37RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • VERIFICARE CODICI (LA TABELLA È TRATTA DA LISTINO)

    RAC Multizone Premium

    Indoor units connectible

    A new line with smooth design enhanced by high quality materials. The same indoor units are connectible either with Multizone Premium outdoor units or with Mono outdoor units.The size 18 of indoor unit is available only for Multi configuration.

    RAK 18QXBRAK 25/35/50RXB

    Indoor unitUnit of meas.

    RAK-18QXB RAK-25RXB RAK-35RXB RAK-50RXB

    Nominal cooling capacity (min - max)

    kW 1.8 (1.0-2.5) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (1.90- 5.20)

    Nominal heating capacity (min - max)

    kW 2.5 (1.1-3.2) 3.20 (0.90- 4.20) 4.00 (0.90- 4.80) 5.80 (2.2- 7.00)

    Cooling sound pressure (SL / L / M / H)

    dB(A) 20/25/30/36 20/26/32/40 22/29/35/42 25/31/39/47

    Heating sound pressure (SL / L / M / H)

    dB(A) 20/26/32/38 20/27/33/40 22/30/35/42 25/31/39/48

    Sound power dB(A) 49 55 60 60

    Cooling air fl ow rate (SL / L / M / H)

    m3/h 300/330/430/500 300/330/510/560 320/340/430/580 350/400/580/720

    Heating air fl ow rate (SL / L / M / H)

    m3/h 310/360/480/600 290/370/560/610 310/360/480/630 350/420/620/800

    Dimensions (H x L x D) mm 295 x 900 x 210 295 x 900 x 210 295 x 900 x 210 295 x 900 x 210

    Weight kg 11 11 11 11

    Piping diameter (Liq / Gas) inch 1/4” / 3/8” 1/4” / 3/8” 1/4” / 3/8” 1/4” / 1/2”

    Condensate drain diameter mm 16 16 16 16

    Remote controller (standard, optional)

    Standard RAR-6N1 RAR-6N1 RAR-6N1 RAR-6N1

    Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB

    Standard fi lter Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22

    Dimensions standard fi lter (H x L x D)

    mm 48x243x5 48x243x5 48x243x5 48x243x5

    Standard Pre-fi lter Stainless steel Stainless steel Stainless steel Stainless steel

    AKEBONO Wall RAK-RXB / RAK-QXB

    (1)

    (1) with presence sensor

    38

    Staging Unit A Staging Unit B

    RAC Multizone Premium

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    A line with traditional design suitble for classic environment. The same indoor units are connectible either with Multizone Premium outdoor units or with Mono outdoor units.The size 15 of indoor unit is available only for Multi configuration.

    RAK 15QPBRAK 18/25/35/50RPB

    Indoor unitUnit

    of meas.RAK-15QPB RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB

    Nominal cooling capacity (min - max)

    kW 1.50 (0.90- 2.00) 2.00 (0.90 - 2.50) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (1.90- 5.20)

    Nominal heating capacity (min - max)

    kW 2.00 (1.00 - 2.50) 2.50 (0.90 - 3.20) 3.40 (0.90- 4.40) 4.20 (0.90- 5.00) 6.00 (2.2- 7.30)

    Cooling sound pressure (SL / L / M / H)

    dB(A) 20/24/30/34 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 25/28/39/46

    Heating sound pressure (SL / L / M / H)

    dB(A) 20/24/32/35 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 27/31/39/46

    Sound power dB(A) 47 51 54 57 60

    Cooling air fl ow rate (SL / L / M / H)

    m3/h 312 / 350 / 400

    / 420 312 / 350 / 400

    / 440 333 / 370 / 430

    / 510 353 /420 / 485

    / 680353/410/540/750

    Heating air fl ow rate (SL / L / M / H)

    m3/h 312 / 350 / 420

    / 480 312 / 350 / 420

    / 480 333 / 400 / 500/

    570 363 / 480 / 570/

    780380/500/610/820

    Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218 295 x 900 x 230 295 x 900 x 230

    Weight kg 7,5 7,5 7,5 10 10

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter mm 16 16 16 16 16

    Remote controller (standard, optional)

    Standard RAR-6N2 RAR-6N2 RAR-6N2 RAR-6N1 RAR-6N1

    Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB

    Standard fi lterWasabi / SPX-

    CFH22Wasabi / SPX-

    CFH22Wasabi / SPX-

    CFH22Wasabi / SPX-

    CFH22Wasabi / SPX-

    CFH22

    Dimensions standard fi lter (H x L x D)

    mm 48x243x5 48x243x5 48x243x5 48x243x5 48x243x5

    Standard Pre-fi lter WASHABLE WASHABLE WASHABLE WASHABLE WASHABLE

    Optional Pre-fi lter Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF7 Stainl. S./SPX-SPF7

    PERFORMANCE Wall RAK-RPB / RAK-QPB

    (1) (2)

    (1) without sensor(2) only for RAK-35RPB, RAK-50RPB

    39RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • AKEBONO Wall RAF-RXB

    RAC Multizone Premium

    Indoor units connectible

    A new line with modern design suitable for casual environment. The same indoor units are connectible either with Multizone Premium outdoor units or with Mono outdoor units.The indoor unit could be either installed leaning on the floor or suspended above the floor without the white stand.

    Indoor unitUnit of meas.

    RAF-25RXB RAF-35RXB RAF-50RXB

    Nominal cooling capacity (min - max)

    kW 2.50 (0.90 - 3.10) 3.5(0.9-4.0) 5.0 (0.9-5.2)

    Nominal heating capacity (min - max)

    kW 3.40 (0.90- 4.40) 4.5(0.9-5.0) 6.0 (0.9-8.1)

    Cooling sound pressure (SL / L / M / H)

    dB(A) 20/26 / 31 /38 20/26/31/39 22/29/36/43

    Heating sound pressure (SL / L / M / H)

    dB(A) 20/26 / 31 /38 20/26/31/39 22/29/36/44

    Sound power dB(A) 55 56 59

    Cooling air fl ow rate (SL / L / M / H)

    m3/h 270 / 390 / 510 / 630 270/390/510/660 300/450/540/720

    Heating air fl ow rate (SL / L / M / H)

    m3/h 300 / 420 / 540/ 660 300/420/540/690 330/480/570/750

    Dimensions (H x L x D) mm 590 x 750 x 215 590 x 750 x 215 590 x 750 x 215

    Weight kg 15 15 15

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter mm 16 16 16

    Remote controller (standard, optional)

    Standard RAR-6N4 RAR-6N4 RAR-6N4

    Optional SPX-RCDB SPX-RCDB SPX-RCDB

    Standard fi lter Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15

    Dimensions standard fi lter (H x L x D)

    mm 48x243x8 48x243x8 48x243x8

    Standard Pre-fi lter Stainless steel Stainless steel Stainless steel

    RAF 25/35/50RXB

    (1)

    (1) without sensor

    40

    Staging Unit A Staging Unit B

    RAC Multizone Premium

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    DUCT Middle Static Pressure RAD-QPB

    Available only for Multi combination. This new compact unit can be mount either in a duct or in a ductless configuration. Depending on whether ductless or linear ducting installation is opted for, fan static pressure may be adjusted via a sui-table selector on the electronic board (max. 69Pa). For further details on static pressure consult Hitachi technical documentation.IR remote controller or wired remote control shall be separately purchased.

    RAD 18/25/35/50QPB

    Indoor unitUnit of meas.

    RAD-18QPB RAD-25QPB RAD-35QPB RAD-50QPB

    Nominal cooling capacity (min - max)

    kW 1.8 (0.9~2.5) 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.6)

    Nominal heating capacity (min - max)

    kW 2.5 (0.9~3.2) 3.5 (0.9-5.5) 4.8 (0.9-6.6) 6.0 (0.9-7.5)

    Cooling sound pressure (SL / L / M / H)

    dB(A) 30/33/37/41 30/33/37/41 30/33/37/41 31/35/39/43

    Heating sound pressure (SL / L / M / H)

    dB(A) 30/34/38/42 30/34/38/42 30/34/38/42 32/35/39/43

    Sound power dB(A) 57 57 57 58Cooling air fl ow rate (SL / L / M / H)

    m3/h 400/480/560/600 400/480/560/600 400/480/570/660 400/480/570/660

    Heating air fl ow rate (SL / L / M / H)

    m3/h 450/520/590/650 450/520/590/650 440/510/600/720 440/510/600/720

    Included condensate drain pump yes yes yes yesMax height available for drain pump

    cm 30 30 30 30

    Drain pump pressure lift

    cm 15 15 15 15

    Static pressure - Air fl ow rate with switch at High position (Cooling / Heating [L / M / H])

    Pa (m3/h)C [42(242)/49(274)/51(291)]H [46(266)/52(293)/57(314)]

    C [42(242)/49(274)/51(291)]H [46(266)/52(293)/57(314)]

    C [44(243)/50(279)/58(323)]H [51(259)/58(289)/69(340)]

    C [44(243)/50(279)/58(323)]H [51(259)/58(289)/69(340)]

    Dimensions (H x L x D) mm 235x750x400 235x750x400 235x750x400 235x750x400

    Weight kg 16 16 16 16

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter mm 16 16 16 16

    Remote controller (standard, optional)

    Standard no no no no

    OptionalSPX-RCDA oSPX-RCKA1

    SPX-RCDA oSPX-RCKA1

    SPX-RCDA oSPX-RCKA1

    SPX-RCDA oSPX-RCKA1

    Standard Pre-fi lter WASHABLE WASHABLE WASHABLE WASHABLE

    (1) (2) (2) (2) (2) (2) (2)

    (2) (2) (2) (2)

    (1) without sensor(2) with IR controller only

    41RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • CASSETTE 4 Way RAI-QPB

    RAC Multizone Premium

    Indoor units connectible

    Available only for Multi combination.Perfect for both modern and classic environments, thanks to pure white aesthetic panel and to minimal design.

    RAI 25/35/50QPBRAI 25/35/50QPB

    Indoor unitUnit of meas.

    RAI-25QPB RAI-35QPB RAI-50QPB

    Nominal cooling capacity (min - max)

    kW 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.2)

    Nominal heating capacity (min - max)

    kW 3.5 (0.9-5.0) 4.8 (0.9-6.6) 6.2 (0.9-7.6)

    Cooling sound pressure (SL / L / M / H)

    dB(A) 28/31/34/37 30/34/38/42 32/36/40/44

    Heating sound pressure (SL / L / M / H)

    dB(A) 29/32/35/38 30/35/39/43 32/36/40/44

    Sound power dB(A) 50 58 58

    Cooling air fl ow rate (SL / L / M / H)

    m3/h 330/360/420/510 390/420/510/650 390/450/510/720

    Heating air fl ow rate (SL / L / M / H)

    m3/h 390/420/480/550 450/480/510/660 450/510/540/720

    Included condensate drain pump yes yes yes

    Max height available for drain pump

    cm 30,4 30,4 30,4

    Drain pump pressure lift cm 11,5 11,5 11,5

    Dimensions (H x L x D) mm 285x580x580 285x580x580 285x580x580

    Weight kg 20 20 20

    Panel weight kg 4 4 4

    Panel dimensions (H x L x D) mm 32x650x650 32x650x650 32x650x650

    Panel code RAI-ECPP RAI-ECPP RAI-ECPP

    Panel colour (RAL) RAL 9010 RAL 9010 RAL 9010

    Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"

    Condensate drain diameter mm 16 16 16

    Remote controller(standard, optional)

    Standard RAR-6N2 RAR-6N2 RAR-6N2

    Optional SPX-RCDB SPX-RCDB SPX-RCDB

    Standard fi lter WASABI / SPX-NTW1 WASABI / SPX-NTW1 WASABI / SPX-NTW1

    Standard fi lter dimensions (H x L x D) mm 35x270x5 35x270x5 35x270x5

    Pre-fi ltro standard WASHABLE WASHABLE WASHABLE

    (1)

    (1) without sensor

    42

    Staging Unit A Staging Unit B

    RAC Multizone Premium

    RAC Catalogue 2015 - Air Conditioning

  • RAC Residential

    43RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • POSSIBLE COMBINATIONS

    RAM-33NP2B RAM-40NP2B RAM-53NP3B RAM-68NP3B RAM-70NP4B RAM-70NP4B

    ON

    E U

    NIT

    - - - - -

    FOU

    R U

    NIT

    S

    1,5+1,5+1,5+1,5

    - - - - - 1,5+1,5+1,5+1,8

    - - - - - 1,5+1,5+1,5+2,5

    - - - - - 1,5+1,5+1,5+3,5

    - - - - - 1,5+1,5+1,5+5,0

    TW

    O U

    NIT

    S

    1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5+1,8+1,8

    1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,5+1,8+2,5

    1,5+2,5 1,5+2,5 1,5+2,5 1,5+2,5 1,5+2,5 1,5+1,5+1,8+3,5

    1,8+1,8 1,5+3,5 1,5+3,5 1,5+3,5 1,5+3,5 1,5+1,5+1,8+5,0

    1,8+2,5 1,8+1,8 1,5+5,0 1,5+5,0 1,5+5,0 1,5+1,5+2,5+2,5

    2,5+2,5 1,8+2,5 1,8+1,8 1,8+1,8 1,8+1,8 1,5+1,5+2,5+3,5

    - 1,8+3,5 1,8+2,5 1,8+2,5 1,8+2,5 1,5+1,5+2,5+5,0

    - 2,5+2,5 1,8+3,5 1,8+3,5 1,8+3,5 1,5+1,5+3,5+3,5

    - 2,5+3,5 1,8+5,0 1,8+5,0 1,8+5,0 1,5+1,5+3,5+5,0

    - - 2,5+2,5 2,5+2,5 2,5+2,5 1,5+1,8+1,8+1,8

    - - 2,5+3,5 2,5+3,5 2,5+3,5 1,5+1,8+1,8+2,5

    - - 3,5+3,5 2,5+5,0 2,5+5,0 1,5+1,8+1,8+3,5

    - - 2,5+5,0 3,5+3,5 3,5+3,5 1,5+1,8+1,8+5,0

    - - 3,5+5,0 3,5+5,0 3,5+5,0 1,5+1,8+2,5+2,5

    - - - 5,0+5,0 5,0+5,0 1,5+1,8+2,5+3,5

    TH

    RE

    E U

    NIT

    S

    - - 1,5+1,5+1,5 1,5+1,5+1,5 1,5+1,5+1,5 1,5+1,8+2,5+5,0

    - - 1,5+1,5+1,8 1,5+1,5+1,8 1,5+1,5+1,8 1,5+1,8+3,5+3,5

    - - 1,5+1,5+2,5 1,5+1,5+2,5 1,5+1,5+2,5 1,5+2,5+2,5+2,5

    - - 1,5+1,5+3,5 1,5+1,5+3,5 1,5+1,5+3,5 1,5+2,5+2,5+3,5

    - - 1,5+1,5+5,0 1,5+1,5+5,0 1,5+1,5+5,0 1,5+2,5+3,5+3,5

    - - 1,5+1,8+1,8 1,5+1,8+1,8 1,5+1,8+1,8 1,8+1,8+1,8+1,8

    - - 1,5+1,8+2,5 1,5+1,8+2,5 1,5+1,8+2,5 1,8+1,8+1,8+2,5

    - - 1,5+1,8+3,5 1,5+1,8+3,5 1,5+1,8+3,5 1,8+1,8+1,8+3,5

    - - 1,5+1,8+5,0 1,5+1,8+5,0 1,5+1,8+5,0 1,8+1,8+1,8+5,0

    - - 1,5+2,5+2,5 1,5+2,5+2,5 1,5+2,5+2,5 1,8+1,8+2,5+2,5

    - - 1,5+2,5+3,5 1,5+2,5+3,5 1,5+2,5+3,5 1,8+1,8+2,5+3,5

    - - 1,5+3,5+3,5 1,5+2,5+5,0 1,5+2,5+5,0 1,8+1,8+3,5+3,5

    - - 1,8+1,8+1,8 1,5+3,5+3,5 1,5+3,5+3,5 1,8+2,5+2,5+2,5

    - - 1,8+1,8+2,5 1,5+3,5+5,0 1,5+3,5+5,0 1,8+2,5+2,5+3,5

    - - 1,8+1,8+3,5 1,8+1,8+1,8 1,8+1,8+1,8 2,5+2,5+2,5+2,5

    - - 1,8+1,8+5,0 1,8+1,8+2,5 1,8+1,8+2,5 2,5+2,5+2,5+3,5

    - - 1,8+2,5+2,5 1,8+1,8+3,5 1,8+1,8+3,5 -

    - - 1,8+2,5+3,5 1,8+1,8+5,0 1,8+1,8+5,0 -

    - - 1,8+3,5+3,5 1,8+2,5+2,5 1,8+2,5+2,5 -

    - - 2,5+2,5+2,5 1,8+2,5+3,5 1,8+2,5+3,5 -

    - - 2,5+2,5+3,5 1,8+2,5+5,0 1,8+2,5+5,0 -

    - - - 1,8+3,5+3,5 1,8+3,5+3,5 -

    - - - 1,8+3,5+5,0 1,8+3,5+5,0 -

    - - - 2,5+2,5+2,5 2,5+2,5+2,5 -

    - - - 2,5+2,5+3,5 2,5+2,5+3,5 -

    - - - 2,5+2,5+5,0 2,5+2,5+5,0 -

    - - - 2,5+3,5+3,5 2,5+3,5+3,5 -

    - - - 2,5+3,5+5,0 2,5+3,5+5,0 -

    - - - 3,5+3,5+3,5 3,5+3,5+3,5 -

    RAC Multizone Premium

    MULTI COMBINATIONS

    44

    Staging Unit A Staging Unit B

    RAC Multizone Premium

    RAC Catalogue 2015 - Air Conditioning

  • POSSIBLE COMBINATIONS

    RAM-90NP5B RAM-90NP5B RAM-90NP5B RAM-90NP5B

    ON

    E U

    NIT

    -

    FOU

    R U

    NIT

    S

    1,5+1,5+1,5+1,5

    FOU

    R U

    NIT

    S

    2,5+2,5+2,5+5,0

    FIV

    E U

    NIT

    S

    1,5+1,8+2,5+3,5+5,0

    - 1,5+1,5+1,5+1,8 2,5+2,5+3,5+3,5 1,5+1,8+3,5+3,5+3,5

    - 1,5+1,5+1,5+2,5 2,5+2,5+3,5+5,0 1,5+1,8+3,5+3,5+5,0

    - 1,5+1,5+1,5+3,5 2,5+2,5+5,0+5,0 1,8+1,8+1,8+1,8+1,8

    - 1,5+1,5+1,5+5,0 2,5+3,5+3,5+3,5 1,8+1,8+1,8+1,8+2,5

    TW

    O U

    NIT

    S

    1,5+1,5 1,5+1,5+1,8+1,8 2,5+3,5+3,5+5,0 1,8+1,8+1,8+1,8+3,5

    1,5+1,8 1,5+1,5+1,8+2,5 3,5+3,5+3,5+3,5 1,8+1,8+1,8+1,8+5,0

    1,5+2,5 1,5+1,5+1,8+3,5 3,5+3,5+3,5+5,0 1,8+1,8+1,8+2,5+2,5

    1,5+3,5 1,5+1,5+1,8+5,0

    FIV

    E U

    NIT

    S

    1,5+1,5+1,5+1,5+1,5 1,8+1,8+1,8+2,5+3,5

    1,5+5,0 1,5+1,5+2,5+2,5 1,5+1,5+1,5+1,5+1,8 1,8+1,8+1,8+2,5+5,0

    1,8+1,8 1,5+1,5+2,5+3,5 1,5+1,5+1,5+1,5+2,5 1,8+1,8+1,8+3,5+3,5

    1,8+2,5 1,5+1,5+2,5+5,0 1,5+1,5+1,5+1,5+3,5 1,8+1,8+1,8+3,5+5,0

    1,8+3,5 1,5+1,5+3,5+3,5 1,5+1,5+1,5+1,5+5,0 1,8+1,8+1,8+5,0+5,0

    1,8+5,0 1,5+1,5+3,5+5,0 1,5+1,5+1,5+1,8+1,8 1,8+1,8+2,5+2,5+2,5

    2,5+2,5 1,5+1,5+5,0+5,0 1,5+1,5+1,5+1,8+2,5 1,8+1,8+2,5+2,5+3,5

    2,5+3,5 1,5+1,8+1,8+1,8 1,5+1,5+1,5+1,8+3,5 1,8+1,8+2,5+2,5+5,0

    2,5+5,0 1,5+1,8+1,8+2,5 1,5+1,5+1,5+1,8+5,0 1,8+1,8+2,5+3,5+3,5

    3,5+3,5 1,5+1,8+1,8+3,5 1,5+1,5+1,5+2,5+2,5 1,8+1,8+2,5+3,5+5,0

    3,5+5,0 1,5+1,8+1,8+5,0 1,5+1,5+1,5+2,5+3,5 1,8+1,8+3,5+3,5+3,5

    5,0+5,0 1,5+1,8+2,5+2,5 1,5+1,5+1,5+2,5+5,0 1,8+2,5+2,5+2,5+2,5

    TH

    RE

    E U

    NIT

    S

    1,5+1,5+1,5 1,5+1,8+2,5+3,5 1,5+1,5+1,5+3,5+3,5 1,8+2,5+2,5+2,5+3,5

    1,5+1,5+1,8 1,5+1,8+2,5+5,0 1,5+1,5+1,5+3,5+5,0 1,8+2,5+2,5+2,5+5,0

    1,5+1,5+2,5 1,5+1,8+3,5+3,5 1,5+1,5+1,5+5,0+5,0 1,8+2,5+2,5+3,5+3,5

    1,5+1,5+3,5 1,5+1,8+3,5+5,0 1,5+1,5+1,8+1,8+1,8 1,8+2,5+2,5+3,5+5,0

    1,5+1,5+5,0 1,5+1,8+5,0+5,0 1,5+1,5+1,8+1,8+2,5 1,8+2,5+3,5+3,5+3,5

    1,5+1,8+1,8 1,5+2,5+2,5+2,5 1,5+1,5+1,8+1,8+3,5 2,5+2,5+2,5+2,5+2,5

    1,5+1,8+2,5 1,5+2,5+2,5+3,5 1,5+1,5+1,8+1,8+5,0 2,5+2,5+2,5+2,5+3,5

    1,5+1,8+3,5 1,5+2,5+2,5+5,0 1,5+1,5+1,8+2,5+2,5 2,5+2,5+2,5+2,5+5,0

    1,5+1,8+5,0 1,5+2,5+3,5+3,5 1,5+1,5+1,8+2,5+3,5 2,5+2,5+2,5+3,5+3,5

    1,5+2,5+2,5 1,5+2,5+3,5+5,0 1,5+1,5+1,8+2,5+5,0 2,5+2,5+3,5+3,5+3,5

    1,5+2,5+3,5 1,5+2,5+5,0+5,0 1,5+1,5+1,8+3,5+3,5 -

    1,5+2,5+5,0 1,5+3,5+3,5+3,5 1,5+1,5+1,8+3,5+5,0 -

    1,5+3,5+3,5 1,5+3,5+3,5+5,0 1,5+1,5+1,8+5,0+5,0 -

    1,5+3,5+5,0 1,5+3,5+5,0+5,0 1,5+1,5+2,5+2,5+2,5 -

    1,5+5,0+5,0 1,8+1,8+1,8+1,8 1,5+1,5+2,5+2,5+3,5 -

    1,8+1,8+1,8 1,8+1,8+1,8+2,5 1,5+1,5+2,5+2,5+5,0 -

    1,8+1,8+2,5 1,8+1,8+1,8+3,5 1,5+1,5+2,5+3,5+3,5 -

    1,8+1,8+3,5 1,8+1,8+1,8+5,0 1,5+1,5+2,5+3,5+5,0 -

    1,8+1,8+5,0 1,8+1,8+2,5+2,5 1,5+1,5+2,5+5,0+5,0 -

    1,8+2,5+2,5 1,8+1,8+2,5+3,5 1,5+1,5+3,5+3,5+3,5 -

    1,8+2,5+3,5 1,8+1,8+2,5+5,0 1,5+1,5+3,5+3,5+5,0 -

    1,8+2,5+5,0 1,8+1,8+3,5+3,5 1,5+1,8+1,8+1,8+1,8 -

    1,8+3,5+3,5 1,8+1,8+3,5+5,0 1,5+1,8+1,8+1,8+2,5 -

    1,8+3,5+5,0 1,8+1,8+5,0+5,0 1,5+1,8+1,8+1,8+3,5 -

    1,8+5,0+5,0 1,8+2,5+2,5+2,5 1,5+1,8+1,8+1,8+5,0 -

    2,5+2,5+2,5 1,8+2,5+2,5+3,5 1,5+1,8+1,8+2,5+2,5 -

    2,5+2,5+3,5 1,8+2,5+2,5+5,0 1,5+1,8+1,8+2,5+3,5 -

    2,5+2,5+5,0 1,8+2,5+3,5+3,5 1,5+1,8+1,8+2,5+5,0 -

    2,5+3,5+3,5 1,8+2,5+3,5+5,0 1,5+1,8+1,8+3,5+3,5 -

    2,5+3,5+5,0 1,8+2,5+5,0+5,0 1,5+1,8+1,8+3,5+5,0 -

    2,5+5,0+5,0 1,8+3,5+3,5+3,5 1,5+1,8+1,8+5,0+5,0 -

    3,5+3,5+3,5 1,8+3,5+3,5+5,0 1,5+1,8+2,5+2,5+2,5 -

    3,5+3,5+5,0 1,8+3,5+5,0+5,0 1,5+1,8+2,5+2,5+3,5 -

    3,5+5,0+5,0 2,5+2,5+2,5+2,5 1,5+1,8+2,5+2,5+5,0 -

    5,0+5,0+5,0 2,5+2,5+2,5+3,5 1,5+1,8+2,5+3,5+3,5 -

    RAC Residential

    45RAC Catalogue 2015 - Air Conditioning

    Staging Unit A Staging Unit B

  • POSSIBLE COMBINATIONS

    RAM-110NP6B RAM-110NP6B RAM-110NP6B RAM-110NP6B RAM-110NP6B

    ON

    E U

    NIT

    (*) -

    FOU

    R U

    NIT

    S1,5+1,8+1,8+5,0

    FIV

    E U

    NIT

    S

    1,5+1,5+1,5+2,5+2,5

    FIV

    E U

    NIT

    S

    1,5+3,5+1,5+1,5+1,8

    FIV

    E U

    NIT

    S

    1,8+5,0+1,8+2,5+3,5

    - 1,5+1,8+2,5+2,5 1,5+1,5+1,5+2,5+3,5 1,5+3,5+1,5+1,5+2,5 3,5+3,5+1,8+1,8+3,5

    - 1,5+1,8+2,5+3,5 1,5+1,5+1,5+3,5+3,5 1,5+3,5+1,5+1,5+3,5 2,5+2,5+1,8+2,5+2,5

    - 1,5+1,8+2,5+5,0 1,5+1,5+1,8+1,8+1,8 1,5+3,5+1,5+1,5+5,0 2,5+3,5+1,8+2,5+2,5

    - 1,5+1,8+3,5+3,5 1,5+1,5+1,8+1,8+2,5 1,5+3,5+1,5+1,8+1,8 1,8+5,0+2,5+2,5+2,5

    TW

    O U

    NIT

    S (*

    )

    - 1,5+1,8+3,5+5,0 1,5+1,5+1,8+1,8+3,5 1,5+3,5+1,5+1,8+2,5 3,5+3,5+1,8+2,5+2,5

    - 1,5+2,5+1,5+2,5 1,5+1,5+1,8+1,8+5,0 1,5+3,5+1,5+1,8+3,5 2,5+5,0+1,8+2,5+3,5

    - 1,5+2,5+2,5+2,5 1,5+1,5+1,8+2,5+2,5 1,5+3,5+1,5+1,8+5,0 3,5+3,5+1,8+2,5+3,5

    - 1,5+2,5+2,5+3,5 1,5+1,5+1,8+2,5+3,5 1,5+3,5+1,5+2,5+2,5 3,5+3,5+1,8+3,5+3,5

    - 1,5+2,5+2,5+5,0 1,5+1,5+1,8+3,5+3,5 1,5+3,5+1,5+2,5+3,5 2,5+2,5+2,5+2,5+2,5

    - 1,5+2,5+3,5+3,5 1,5+1,5+2,5+2,5+2,5 1,5+3,5+1,5+3,5+3,5 2,5+3,5+2,5+2,5+2,5

    - 1,5+2,5+3,5+5,0 1,5+1,5+2,5+2,5+3,5 1,5+3,5+1,8+1,8+1,8 2,5+5,0+2,5+2,5+2,5

    - 1,5+3,5+1,5+3,5 1,5+1,8+1,5+1,5+1,5 1,5+3,5+1,8+1,8+2,5 3,5+3,5+2,5+2,5+2,5

    - 1,5+3,5+3,5+3,5 1,5+1,8+1,5+1,5+1,8 1,5+3,5+1,8+1,8+3,5 2,5+5,0+2,5+2,5+3,5

    - 1,5+3,5+3,5+5,0 1,5+1,8+1,5+1,5+2,5 1,5+3,5+1,8+1,8+5,0 3,5+3,5+2,5+2,5+3,5

    - 1,5+5,0+1,5+5,0 1,5+1,8+1,5+1,5+3,5 1,5+3,5+1,8+2,5+2,5 3,5+5,0+2,5+2,5+3,5

    - 1,8+1,8+1,8+1,8 1,5+1,8+1,5+1,5+5,0 1,5+3,5+1,8+2,5+3,5

    SIX

    UN

    ITS

    1,5+1,5+1,5+1,5+1,5+1,5

    - 1,8+1,8+1,8+2,5 1,5+1,8+1,5+1,8+1,8 1,5+3,5+1,8+3,5+3,5 1,5+1,5+1,5+1,5+1,5+1,8

    - 1,8+2,5+1,8+2,5 1,5+1,8+1,5+1,8+2,5 1,5+3,5+2,5+2,5+2,5 1,5+1,5+1,5+1,5+1,5+2,5

    TH

    RE

    E U

    NIT

    S (*

    )

    - 1,8+1,8+1,8+3,5 1,5+1,8+1,5+1,8+3,5 1,5+3,5+2,5+2,5+3,5 1,5+1,5+1,5+1,5+1,5+3,5

    - 1,8+2,5+1,8+3,5 1,5+1,8+1,5+1,8+5,0 1,5+5,0+1,5+1,5+1,5