Radiation measurement and comparison between VT/CM tests at KEK-STF. Kirk. Radiation Detector in KEK-STF. There are two types of detectors, MAR-781 and MAR-782. Specifications: Radiation detected: X-ray and γ -ray Detector type: Silicon semiconductor Energy range: 50 keV to 6 MeV - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/1.jpg)
2014/3/25 TTC Meeting 2014@DESY 1
Radiation measurement and comparison between VT/CM
tests at KEK-STF
Kirk
![Page 2: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/2.jpg)
2014/3/25 TTC Meeting 2014@DESY 2
Radiation Detector in KEK-STF
http://www.hitachi-aloka.co.jp/english/products/data/radiation-011-MAR781782
There are two types of detectors, MAR-781 and MAR-782.
Specifications: Radiation detected: X-ray and γ-rayDetector type: Silicon semiconductorEnergy range: 50 keV to 6 MeVMeasurement range: 0.1-999.9μSv/h
0.001-99.99mSv/hAccuracy: within ±10%
These detectors are used in VT and CT.But, each position is different.
![Page 3: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/3.jpg)
2014/3/25 TTC Meeting 2014@DESY 3
①
②
③
~100cm
Floor of pit
Center of Beam Axis
Floor of pit
~80cm
Detector position in VT areaCavity position is 4m below from top plate of cryostat.
![Page 4: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/4.jpg)
2014/3/25 TTC Meeting 2014@DESY 4
①
②
③
~100cm
Floor of pit
Center of Beam Axis
Floor of pit
~80cm
Detector position in VT areaCavity position is 4m below from top plate of cryostat.
Radiation level depends on material kind and thickness, and distance from a cavity.Representatively, we use “On beam axis” position.
![Page 5: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/5.jpg)
2014/3/25 TTC Meeting 2014@DESY 5
Detector position in CT area
Set positions of radiation detector
“S1-Global” cryomodule
There is “No” detector on beam axis in CT!
![Page 6: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/6.jpg)
2014/3/25 TTC Meeting 2014@DESY 6
UX-ray
Cryomodule - C Cryomodule - A
DX-ray
MX-ray
C1 C2 C3 C4 A1 A2 A3 A4
Degradationof Eacc,max
TunerTroubleTuner
Trouble
CouplerVacuum
Up-stream Down-stream
Comparison of cavity performance
E. Kako
![Page 7: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/7.jpg)
2014/3/25 TTC Meeting 2014@DESY 7
Comparison of cavity performanceDegradationof Eacc,max
C2
C3
C4
C1
A1 A2
A3A4
at 25MV/m
at 25MV/m
E. Kako
![Page 8: Radiation measurement and comparison between VT/CM tests at KEK-STF](https://reader036.vdocuments.net/reader036/viewer/2022062411/56816736550346895ddbe601/html5/thumbnails/8.jpg)
2014/3/25 TTC Meeting 2014@DESY 8
Conclusion
There is no simple comparison of radiation level between VT and CT in KEK-STF.
Different location On axis/Off axis, distance from cavity
Different material and thickness Cryostat design/material, different thickness
Different operation mode (CW/pulse) Dependence on time response/accuracy of radiation detector