Page 1: rAPId exAmS SALIVA druG TeST TrAINING

Forensic Use or export only

rAPId exAmS SALIVA druG TeST TrAINING

Page 2: rAPId exAmS SALIVA druG TeST TrAINING

FEATURES

oral Fluid Test with Sponge Saturation Indicator

• Sponge Saturation Indicator (Patent Pending)• Tests exclusive to this device: Cotinine (50 ng/mL),

EDDP (20 ng/mL), Ketamine (50 ng/mL)• 100% tamper evident – saliva held airtight for

confi rmation• Sponge reduces viscosity for faster-running tests• Detect up to 10 drugs including alcohol• One drug per strip for superior accuracy and sensitivity

AVAILABLE DRUGSAlcohol (ALC) .02%

Amphetamine (AMP) 50

Barbiturates (BAR) 50

Benzodiazepines (BZO) 10

Buprenorphine (BUP) 5

Cocaine (COC) 20

Cotinine (COT) 50

EDDP 20

Ketamine (KET) 50

Marijuana (THC)(parent)

1250

Methadone (MTD) 30

Methamphetamine (MET)

50

Opiates (OPI) 40

Oxycodone (OXY) 20

Phencyclidine (PCP) 10

Propoxyphene (PPX) 50

All cutoffs in ng/mL except alcohol

Forensic Use or export only

Page 3: rAPId exAmS SALIVA druG TeST TrAINING

Screening Device (A) Collection Swab (B)

Test strips

Indicator window

Test results area

Saturation indicator

strip

Locking fl ange

Sponge

Page 4: rAPId exAmS SALIVA druG TeST TrAINING

Testing Procedure

1

Remove device from foil pouch

Remove collection swab from plastic pouch

Page 5: rAPId exAmS SALIVA druG TeST TrAINING

Procedure: Specimen collection

2 IMPORTANT: DONORS SHOULD NOT PLACE ANYTHING (INCLUDING FOOD, DRINK, GUM AND TOBACCO PRODUCTS) IN THEIR MOUTH FOR AT LEAST 10 MINUTES PRIOR TO THE PROCEDURE. DO NOT BITE, SUCK, OR CHEW ON THE SPONGE. REFRAIN FROM TALKING WHILE COLLECTION SWAB IS IN THE MOUTH.

10 min.C

T

INVALIDPOSITIVE(+)

NEGATIVE(-)

Page 6: rAPId exAmS SALIVA druG TeST TrAINING

Procedure: Specimen collection

2

The purpose of Step 2 is to saturate the sponge with saliva. With collection swab, have donor sweep the inside of mouth (cheek, gums, tongue) several times, then hold swab in closed mouth until color on the saturation indicator strip appears in the indicator window of the collection swab. Donor must leave swab in mouth until instructed to remove it. note: if at 7 minutes, color on saturation indicator has not appeared in indicator window, proceed with test.

Donor may remove swab from mouth when

color appears in the indicator window

Sponge Saturation Indicator

Page 7: rAPId exAmS SALIVA druG TeST TrAINING

Procedure: Assay

3Remove collection swab (B) from mouth and insert it sponge first into the screening device (A), pushing until the locking flange locks in place in the bottom of the device.

NOTE: Once the collection swab locks in place, the device is airtight, tamper evident, and ready to dispose of or send to lab for confirmation (on presumptive positive result).

Page 8: rAPId exAmS SALIVA druG TeST TrAINING

Procedure: Assay

3Ensure that specimen is contacting all test strips. If not, rotate the device side to side / front to back to disperse the specimen within the chamber. With specimen dispersed, set device upright on flat surface and keep upright while test is running.

45° max. rotation

Page 9: rAPId exAmS SALIVA druG TeST TrAINING

10 min.C

T

INVALIDPOSITIVE(+)

NEGATIVE(-)

Procedure: Interpret results

4

Read negative results as soon as two lines appear on any test strip, often within 2 minutes. Any indication of a line in the test region (T) should be considered a line, and therefore a negative result. Read presumptive positive results at 10 minutes. If the device includes alcohol, read the alcohol strip at 2 minutes.