re-rake detailstable of contents re-rake details fe2010 - cbc - rake detail w/wall panel fe2015 -...

7
RAKE DETAILS FE2010-CBC - RAKE DETAIL w WALL PANELS FE2015-CBC - RAKE DETAIL w ROOF JOIST & WALL PANELS FE2050-CBC - OPEN RAKE DETAIL w WALL CONSTRUCTION BY OTHERS FE2055-CBC - STARTING RAKE DETAIL w JOIST & WALL SYSTEM BY OTHERS FE2610-CBC - STARTING RAKE DETAIL w INSULATED WALL SYSTEM FE2615-CBC - RAKE DETAIL w ROOF JOIST & INSULATED WALL SYSTEM TABLE OF CONTENTS

Upload: others

Post on 23-Feb-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RE-RAKE DETAILSTABLE OF CONTENTS RE-RAKE DETAILS FE2010 - CBC - RAKE DETAIL W/WALL PANEL FE2015 - CBC - RAKE DETAIL W/JOIST & WALL PANEL FE2050 - CBC - OPEN RAKE DETAIL W/ WALL SYSTEM

RAKE DETAILSFE2010-CBC - RAKE DETAIL w WALL PANELSFE2015-CBC - RAKE DETAIL w ROOF JOIST & WALL PANELSFE2050-CBC - OPEN RAKE DETAIL w WALL CONSTRUCTION BY OTHERSFE2055-CBC - STARTING RAKE DETAIL w JOIST & WALL SYSTEM BY OTHERSFE2610-CBC - STARTING RAKE DETAIL w INSULATED WALL SYSTEMFE2615-CBC - RAKE DETAIL w ROOF JOIST & INSULATED WALL SYSTEM

TABLE OF CONTENTS

Page 2: RE-RAKE DETAILSTABLE OF CONTENTS RE-RAKE DETAILS FE2010 - CBC - RAKE DETAIL W/WALL PANEL FE2015 - CBC - RAKE DETAIL W/JOIST & WALL PANEL FE2050 - CBC - OPEN RAKE DETAIL W/ WALL SYSTEM

SL

LOWER INSULATION

ROOF SECONDARY MEMBER (SHAPE VARIES)

UPPER INSULATION

WALL INSULATION

R-Boost™ RAKE DETAIL

FE2010RAKE DETAIL w/ STANDARD WALL PANELS

H1020 FASTENER

RAKE TRIM MK. TR-50

RAKE TRIM CLEAT, TR-27 w/WALL SMS, MK. (H1061) @ 12" O.C.

*"R"-PANEL BM-8REVERSE "R" BM-7

WALL PANEL

"A"-PANELREVERSE "A"

BM-6BM-5

MARK No.OUTSIDE PANEL CLOSURES

*

INSULATION BRIDGE MK. EIB24

SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF

RAKE SUPPORT CLIP MK. CL21STw/ (2) H1220 FASTENERSAT EACH PURLIN(SEE DETAIL ABOVE)

VARIES

TOP

OFBR

IDGE

TOP O

FPA

NEL

START/END DIM. / CUT PANEL DIM.(SEE PLAN)

1/4"STEEL LINE

THERMAL BLOCK (IF REQ'D)

H1020 FASTENERAT EACH SUPPORT

WALL PANEL

RAKE ANGLEMK. MAR01

RAKE SUPPORTANGLE RSA_

WALL STRUCTURAL FASTENERMK. (H1041) @ 6" O.C.

CLOSURE

RETAINER CEE MK. IRC

FASTENER, MK.(H1030) @ 6"O.C.

(2) H1220 FASTENERS AT EACHCL21ST UNDER RAKE ANGLEFOR SUPPORT (DO NOT ATTACHTO TO RAKE ANGLE)

ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL

H1020/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION

INSULATION BRIDGEMK. EIB24

RAKE ANGLEMK. MAR01

RETAINER CEEMK. IRC

(2) H1220FASTENERS

*

**

RAKE SUPPORT CLIP CL21ST@ EACH PURLIN

ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPARATION WILL VARY BETWEEN THE STARTINGAND ENDING RAKES, SEE BRIDGE INSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.

*

H1020FASTENERS

*

H1020 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED

USED WHEN WALL PANELS ARE INSTALLED FIRST

SUPER TALL 4 7/8"TALL 3 7/8"***

ROOF PANEL

3/4" TAPE MASTIC,MK. (H3000)

H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE

Detail Size (W x H) :By :

: CERTIFIED ERECTION DETAILSIssuedIssued

Detailer Notes:

Download the DWG file by clicking here.

RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM

FE2010 - RAKE DETAIL w/ WALL PANELS

02.12.21 (MR2021.003)DLM

1 x 2

1) Default option for Wall Closures is shown as being required. Detailer must manually remove illustrations if needed.

Page 3: RE-RAKE DETAILSTABLE OF CONTENTS RE-RAKE DETAILS FE2010 - CBC - RAKE DETAIL W/WALL PANEL FE2015 - CBC - RAKE DETAIL W/JOIST & WALL PANEL FE2050 - CBC - OPEN RAKE DETAIL W/ WALL SYSTEM

SL

LOWER INSULATION(NOT BY NBG)

ROOF JOIST

UPPER INSULATION(NOT BY NBG)

WALLINSULATION

FE2015RAKE DETAIL w/ ROOF JOIST AND STANDARD WALL PANELSR-Boost™ RAKE DETAIL

RAKE ANGLEMK. MAR01

1/4 - 14 X 1 1/4"(H1020) FASTENER

RAKE SUPPORT CLIP MK. CL21STw/ (2) H1220 FASTENERS @ EACHJOIST (INSTALL PRIOR TO WALLPANEL SEE DETAIL ABOVE)

INSULATION BRIDGE MK. EIB24

*"R"-PANEL BM-8REVERSE "R" BM-7

WALL PANEL

"A"-PANELREVERSE "A"

BM-6BM-5

MARK No.OUTSIDE PANEL CLOSURES

*

(2) H1220 FASTENERS @ EACHJOIST UNDER RAKE ANGLEFOR SUPPORT.(DO NOT ATTACH TORAKE ANGLE)

H1070 FASTENER@ EACH SUPPORT

WALL PANEL

RETAINER CEE MK. IRC

PANEL CLIP w/(2)H1020 FASTENERS

THERMAL BLOCK (IF REQ'D)

START/END DIM. / CUT PANEL DIM.(SEE PLAN)

1/4"STEEL LINE

CLOSURE

ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.

*

*

ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL

H1070/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION

INSULATION BRIDGEMK. EIB24

RAKE ANGLEMK. MAR01

RETAINER CEEMK. IRC

(2) H1220FASTENERS

*

**

RAKE SUPPORT CLIP CL21ST@ EACH PURLIN

H1020FASTENERS

H1070 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED

USED WHEN WALL PANELS ARE INSTALLED FIRST

SUPER TALL 4 7/8"TALL 3 7/8"***

SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF

ROOF PANEL

RAKE TRIM CLEAT, TR-27 w/WALL SMS, MK. (H1061) @ 12" O.C.

WALL STRUCTURAL FASTENERMK. (H1041) @ 6" O.C.

RAKE TRIM MK. TR-50

RAKE SUPPORTANGLE RSA_

FASTENER, MK.(H1030) @ 6"O.C.3/4" TAPE MASTIC,MK. (H3000)

H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE

Detail Size (W x H) :By :

: CERTIFIED ERECTION DETAILSIssuedIssued

Detailer Notes:

Download the DWG file by clicking here.

RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM

FE2015 - RAKE DETAIL w/ROOF JOIST & WALL PANELS

02.12.21 (MR2021.003)DLM

1 x 2

1) WALL CLOSURES SUPPLIED IS THE DEFAULT OPTION WITH THIS DETAIL. IF CLOSURES ARE NOTREQUIRED PER CONTRACT. DETAILER MUST MODIFY ILLUSTRATIONS ACCORDINGLY.

Page 4: RE-RAKE DETAILSTABLE OF CONTENTS RE-RAKE DETAILS FE2010 - CBC - RAKE DETAIL W/WALL PANEL FE2015 - CBC - RAKE DETAIL W/JOIST & WALL PANEL FE2050 - CBC - OPEN RAKE DETAIL W/ WALL SYSTEM

LOWER INSULATION

ROOF SECONDARY MEMBER (SHAPE VARIES)

INSULATION BRIDGE MK. EIB24

R-Boost™ OPEN RAKE DETAIL

FE2050STARTING RAKE DETAIL, OPEN FOR WALL w/CONSTRUCTION BY OTHERS

WALL SYSTEM(BY OTHERS)

RAKE TRIM TR-50

ROOF PANELTAPE SEALANT

RAKE TRIMCLEAT MK. TR-27

H1020 FASTENER

THERMAL BLOCK (IF REQ'D)

PANEL CLIP W/(2)H1020 FASTENERS

(2) H1220 FASTENERS@ EACH PURLINUNDER RAKE ANGLEFOR SUPPORT. (DONOT ATTACH TORAKE ANGLE)

RAKE ANGLEMK. MAR02

FIELD CUTBRIDGE

RETAINER CEEMK. IRC__

RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIOR TOWALL PANEL SEE DETAIL ABOVE)

FASTENER1'-0"O.C. MAX.(BY OTHERS)

RAKE SUPPORT ANGLE RSA_

START/END DIM. / CUT PANEL DIM. (SEE PLAN)1/4"STEEL LINE

(NOT BY NBG)

(NOT BY NBG)

*

FASTENER MK.(H1030) @ 6"o.c.

ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.

*

UPPER INSULATIONRAKE ANGLEMK. MAR02

SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF

H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE

ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL

H1020/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION

INSULATION BRIDGEMK. EIB24

RAKE ANGLEMK. MAR01

RETAINER CEEMK. IRC

(2) H1220FASTENERS

*

**

RAKE SUPPORT CLIP CL21ST@ EACH PURLIN

H1020FASTENERS

H1020 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED

USED WHEN WALL PANELS ARE INSTALLED FIRST

SUPER TALL 4 7/8"TALL 3 7/8"***

Detail Size (W x H) :By :

: CERTIFIED ERECTION DETAILSIssuedIssued

Detailer Notes:

Download the DWG file by clicking here.

RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM

FE2050 - OPEN RAKE DETAIL w/ WALL CONSTRUCTION BY OTHERS

02.12.21 (MR2021.003)DLM

1 x 2

1) N/A

Page 5: RE-RAKE DETAILSTABLE OF CONTENTS RE-RAKE DETAILS FE2010 - CBC - RAKE DETAIL W/WALL PANEL FE2015 - CBC - RAKE DETAIL W/JOIST & WALL PANEL FE2050 - CBC - OPEN RAKE DETAIL W/ WALL SYSTEM

R-Boost™ OPEN WALL RAKE DETAIL

FE2055STARTING RAKE DETAIL w/ JOIST AND WALL OPEN FOR WALL SYSTEM BY OTHERS

LOWER INSULATION

UPPER INSULATION

INSULATION BRIDGEMK. EIB24

THERMAL BLOCK (IF REQ'D)

PANEL CLIP W/(2)H1020 FASTENERS

ROOF JOIST

WALL SYSTEM(BY OTHERS)

(2) H1220 FASTENERS @EACH JOIST UNDER RAKEANGLE FOR SUPPORT.(DO NOT ATTACH TORAKE ANGLE)

RAKE ANGLEMK. MAR02

H1070 FASTENER@ EACH SUPPORT

RAKE ANGLEMK. MAR02

FIELD CUTBRIDGE

H1020 FASTENER

RETAINER CEEMK. IRC__

RAKE TRIMCLEAT MK. TR-27

FASTENER12" O.C. MAX.(BY OTHERS)

(NOT BY NBG)

(NOT BY NBG)

START/END DIM. / CUT PANEL DIM. (SEE PLAN)1/4"STEEL LINE

C OF 1ST PANEL RIBL

*

ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.

*

ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL

H1070/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION

INSULATION BRIDGEMK. EIB24

RAKE ANGLEMK. MAR01

RETAINER CEEMK. IRC

(2) H1220FASTENERS

*

**

RAKE SUPPORT CLIP CL21ST@ EACH PURLIN

H1020FASTENERS

H1070 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED

USED WHEN WALL PANELS ARE INSTALLED FIRST

SUPER TALL 4 7/8"TALL 3 7/8"***

SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF

ROOF PANEL

RAKE TRIM MK. TR-50

RAKE SUPPORTANGLE RSA_

FASTENER, MK.(H1030) @ 6"O.C.3/4" TAPE MASTIC,MK. (H3000)

H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE

RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIOR TOWALL PANEL SEE DETAIL ABOVE)

Detail Size (W x H) :By :

: CERTIFIED ERECTION DETAILSIssuedIssued

Detailer Notes:

Download the DWG file by clicking here.

RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM

FE2055 - STARTING RAKE DETAIL w/ ROOF JOIST & WALL SYSTEM BY OTHERS

02.12.21 (MR2021.003)DLM

1 x 2

1) N/A

Page 6: RE-RAKE DETAILSTABLE OF CONTENTS RE-RAKE DETAILS FE2010 - CBC - RAKE DETAIL W/WALL PANEL FE2015 - CBC - RAKE DETAIL W/JOIST & WALL PANEL FE2050 - CBC - OPEN RAKE DETAIL W/ WALL SYSTEM

SL

LOWER INSULATION

ROOF SECONDARY MEMBER (SHAPE VARIES)

UPPER INSULATION

R-Boost™ RAKE DETAIL FE2610RAKE DETAIL w/ INSULATED WALL PANELS

INSULATEDWALL PANEL

38"Ø BEAD OF BUTYL CAULKMARRY VERTICAL CAULKTO CONTINUOUS CAULK

H1020 FASTENER

(2) H1220 FASTENERS@ EACH PURLIN UNDERRAKE ANGLE FORSUPPORT (DO NOTATTACH TO RAKE ANGLE)

INSULATION BRIDGE MK. EIB24

RAKE TRIM CLEAT TR-27 w/#14x 7/8" SMS, (BS-2) @ 1'-0" O.C.

RETAINER CEEMK. IRC

H1020 FASTENER@ EACH SUPPORT

RAKE ANGLEMK. MAR01

CONTINUOUS 3/8" Ø BEAD OF BUTYLCAULK BETWEEN PANEL & EAVE ZEE

CONTINUOUS 3/8" Ø BEAD OF BUTYLCAULK IN VERTICAL JOINT (DO NOT OVERFILL)

PANEL CLIP WC-01w/(2) MEMBER FASTENERS

PANEL CLIP w/(2)H1020 FASTENERS

THERMAL BLOCK (IF REQ'D)

1/4"STEEL LINE

(NOT BY NBG)

(NOT BY NBG)

*Adjust

*

ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.

*

ALT. CL21ST SUPPORT CLIP INSTALLATION DETAIL

H1020/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION

INSULATION BRIDGEMK. EIB24

RAKE ANGLEMK. MAR01

RETAINER CEEMK. IRC

(2) H1220FASTENERS

*

**

RAKE SUPPORT CLIP CL21ST@ EACH PURLIN

H1020FASTENERS

H1020 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED

USED WHEN WALL PANELS ARE INSTALLED FIRST

SUPER TALL 4 7/8"TALL 3 7/8"***

SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF

RAKE TRIM "TR-50", * Note: (Adjust Trim asrequired for Insulated Wall Panel thickness).

ROOF PANEL

RAKE SUPPORTANGLE RSA_

FASTENER, MK.(H1030) @ 6"O.C.3/4" TAPE MASTIC,MK. (H3000)

H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE

RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIORTO WALL PANEL SEE DETAIL ABOVE)

START/END DIM. / CUT PANEL DIM. (SEE PLAN)

Detail Size (W x H) :By :

: CERTIFIED ERECTION DETAILSIssuedIssued

Detailer Notes:

Download the DWG file by clicking here.

RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM

FE2610 - STARTING RAKE DETAIL w/ INSULATED WALL SYSTEM

02.12.21 (MR2021.003)DLM

1 x 2

1) N/A

Page 7: RE-RAKE DETAILSTABLE OF CONTENTS RE-RAKE DETAILS FE2010 - CBC - RAKE DETAIL W/WALL PANEL FE2015 - CBC - RAKE DETAIL W/JOIST & WALL PANEL FE2050 - CBC - OPEN RAKE DETAIL W/ WALL SYSTEM

LOWER INSULATION(NOT BY NBG)

ROOF JOIST

UPPER INSULATION(NOT BY NBG)

WALL INSULATION

FE2615RAKE DETAIL w/ JOIST & INSULATED WALL PANELR-Boost™ RAKE DETAIL

SL

INSULATEDWALL PANEL

CONTINUOUS BUTYL CAULKIN VERTICAL JOINT(DO NOT OVERFILL)

H1020 FASTENER

RAKE TRIM "TR-50", * Note: (Adjust Trim asrequired for Insulated Wall Panel thickness).

ROOF PANEL

INSULATION BRIDGE MK. EIB24

38"Ø BEAD OF BUTYL CAULK

MARRY VERTICAL CAULKTO CONTINUOUS CAULK

RAKE TRIM CLEAT TR-27W/ #14x 7/8" SMS, (BS-2)@ 12" O.C.

PANEL CLIP W/(2)H1020 FASTENERS

THERMAL BLOCK (IF REQ'D)

START/END DIM. / CUT PANEL DIM.(SEE PLAN)

1/4"STEEL LINE

RAKE ANGLEMK. MAR01

RETAINER CEEMK. IRCCONTINUOUS 3/8" Ø BEAD OF BUTYLCAULK BETWEEN PANEL & EAVE ZEE

H1070 FASTENER@ EACH JOIST

(2) H1220 FASTENERS@ EACH JOIST UNDERRAKE ANGLE FORSUPPORT.(DO NOT ATTACH TORAKE ANGLE)

PANEL CLIP WC-01w/(2) MEMBER FASTENERS

VARIES

TOP

OF P

ANEL

TOP OF PANEL

7 1/2"

MIN

.TO

P OF

BRI

DGE

*Adjust

*

ALT. CL21ST SUPPORT CLIP INSTALLATION DETAILUSED WHEN WALL PANELS ARE INSTALLED FIRST

ERECTOR NOTE:STARTING RAKE CONDTION IS SHOWN. BRIDGE PREPERATION WILLVARY BETWEEN THE STARTING AND ENDING RAKES, SEE BRIDGEINSTALLATION DETAILS FOR SPECIFIC BRIDGE REQUIREMENTS.

*

H1070/H2200 EACH END & 2'-0"O.C. BETWEEN PURLINS TO TIEDOWN INSULATION

INSULATION BRIDGEMK. EIB24

RAKE ANGLEMK. MAR01

RETAINER CEEMK. IRC

(2) H1220FASTENERS

*

**

RAKE SUPPORT CLIP CL21ST@ EACH PURLIN

H1020FASTENERS

SUPER TALL 4 7/8"TALL 3 7/8"***

SEE ABOVE FOR FASTENERREQUIREMENTS FOR IRC &INSULATION TIE OFF

H1070 FASTENERAT EACH SUPPORT(2) H1070 FASTENERS @ EACH PURLINPRIOR TO INSULATION BEING INSTALLED

RAKE SUPPORTANGLE RSA_

FASTENER, MK.(H1030) @ 6"O.C.3/4" TAPE MASTIC,MK. (H3000)

H1020 AT 24" O.C. W/ 3/4" TAPE MASTIC, MK. (H3000)BETWEEN ROOF PANEL & RAKE SUPPORT ANGLE

RAKE SUPPORT CLIP MK. CL21ST w/ (2) H1220FASTENERS @ EACH PURLIN (INSTALL PRIORTO WALL PANEL SEE DETAIL ABOVE)

Detail Size (W x H) :By :

: CERTIFIED ERECTION DETAILSIssuedIssued

Detailer Notes:

Download the DWG file by clicking here.

RAKE DETAILSR-Boost™ ELEVATED INSULATION SYSTEM

FE2615 - RAKE DETAIL w/ROOF JOIST & INSULATED WALL SYSTEM

02.12.21 (MR2021.003)DLM

1 x 2

1) PANEL REQUIRES 2 1/2" MINIMUM BEARING ON RAKE ANGLE TO ALLOW ROOM FOR (2) FASTENERS.