asam tl1 part 5

166
3EC 36876 AEAA TCZZA Edition 02 7300 ASAM TL1 Commands and Messages Part 5/5

Upload: paillecp

Post on 29-Nov-2014

506 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Asam Tl1 Part 5

3EC 36876 AEAA TCZZA Edition 02

7300 ASAM

TL1 Commands and Messages

Part 5/5

Page 2: Asam Tl1 Part 5

2 / 166 3EC 36876 AEAA TCZZA Edition 02

Status Released

Change Note B D Fa a42761

Short Title TL1 Commands & Messages

All rights reserved. Passing on and copying of thisdocument, use and communication of its contentsnot permitted without written authorization from Alcatel.

Page 3: Asam Tl1 Part 5

Contents

3 / 1663EC 36876 AEAA TCZZA Edition 02

Contents

1 E1 Commands and Messages 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1 E1 Commands 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.1 DLT�E1 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.2 ED�E1 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.3 ENT�E1 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.4 OPR�LPBK�E1 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.5 REPT�OPSTAT�E1 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.6 RLS�LPBK�E1 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.7 RTRV�ALM�E1 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.8 RTRV�ATTR�E1 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.9 RTRV�COND�E1 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.10 RTRV�PM�E1 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.11 RTRV�E1 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.12 SET�ATTR�E1 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2 E1 Autonomouse Messages 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2.1 REPT ALM E1 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2.2 REPT EVT E1 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.3 E1 Conditions 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.4 E1 Monotypes 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 E3 Commands and Messages 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1 E3 Commands 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.1 ED�E3 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.2 RTRV�ALM�E3 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.3 RTRV�ATTR�E3 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.4 RTRV�COND�E3 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.5 RTRV�PM�E3 62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.6 RTRV�E3 65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.7 SET�ATTR�E3 68. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2 E3 Autonmous Messages 70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2.1 REPT ALM E3 70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2.2 REPT EVT E3 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.3 E3 Conditions 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.4 E3 Monotypes 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 Environmental Commands and Messages 77. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1 ENV Commands 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1.1 RTRV�ALM�ENV 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1.2 RTRV�ATTR�ENV 80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1.3 RTRV�COND�ENV 82. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1.4 SET�ATTR�ENV 84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4: Asam Tl1 Part 5

Contents

4 / 166 3EC 36876 AEAA TCZZA Edition 02

3.2 ENV Autonomous Messages 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.2.1 REPT ALM ENV 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.3 Environmental (ENV) Conditions 88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 Miscellaneous System Commands 89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.1 DLT�MEM 90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2 ED�SYNCN 92. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.3 FREE�PORT 94. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.4 INIT�LOG 96. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.5 INIT�SYS 98. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.6 RD�SYNCN 101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.7 REPT�OPSTAT�ICON 103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.8 REPT�OPSTAT�NE 105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.9 RESV�NEXT�PORT 109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.10 RST�MEM 112. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.11 RTRV�CMDSSN 114. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.12 RTRV�HDR 116. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.13 RTRV�LOG 118. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.14 RTRV�MEM 120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.15 RTRV�NE�ALL 122. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.16 RTRV�PORT 126. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.17 RTRV�SYNCN 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.18 SET�DAT 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.19 SET�NE�ALL 132. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.20 SET�SID 135. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.21 STA�CMDSSN 137. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.22 STP�CMDSSN 139. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix A Alarms and Events 141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix B Error Codes 151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix C ATM Addressing 153. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix D System Access Identifiers 157. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5: Asam Tl1 Part 5

Contents

5 / 1663EC 36876 AEAA TCZZA Edition 02

Figures

Figure 1 Standard Density ASAM (NE) Equipment Arrangement 157. . . . . . . . . . . . . .

Figure 2 High Density ASAM (NE) Equipment Arrangement 158. . . . . . . . . . . . . . . . . .

Figure 3 Ultra Density ASAM (NE) Equipment Arrangement 159. . . . . . . . . . . . . . . . . .

Tables

Table 1 E1 Conditions 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 2 E1 Monotypes 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 3 E3 Conditions 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 4 E3 Monotypes 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 5 ENV Conditions 88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6: Asam Tl1 Part 5

Contents

6 / 166 3EC 36876 AEAA TCZZA Edition 02

Page 7: Asam Tl1 Part 5

1 E1 Commands and Messages

7 / 1663EC 36876 AEAA TCZZA Edition 02

1 E1 Commands and Messages

This chapter provides information about the E1 commands and

messages. The chapter has the following main parts:

� E1 Commands

� E1 Autonomous Messages

� E1 Conditions

� E1 Monotypes.

Page 8: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

8 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1 E1 Commands

This section describes the E1 commands.

1.1.1 DLT�E1

Deletes an existing E1 facility in the NE.

All parameters in this command are position�defined.

DLT-E1:[tid]:aid_e1:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing

lower�case parameters with the values given:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Page 9: Asam Tl1 Part 5

Response Format

Example

Related Command

1 E1 Commands and Messages

9 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* DLT-E1:[tid]:aid_e1:[ctag][:] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* DLT-E1:[tid]:aid_e1:[ctag][:] */ errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix C)

Delete LT E1 circuit located at rack 3, shelf 2, slot 6.

DLT-E1:RALGH:LTE1-3-2-6:42;

RALGH 00-11-24 12:30:43M 42 COMPLD /* DLT-E1:RALGH:LTE1-3-2-6:42 */;

ED�E1

Page 10: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

10 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1.2 ED�E1

Edits the provisioning data associated with an E1 facility. It

optionally allows modification of associated ATM interface

parameters if this facility is provisioned in native ATM (non�IMA)

mode.

All parameters in this command are position�defined.

The ATM interface must be provisioned with the ENT�E1 or

ED�ATMPORT commands before ATM parameters are edited.

ED-E1:[tid]:aid_e1:[ctag]:::[e1_nblk]:[pst];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing

lower�case parameters with the values given:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the Nt or LT (1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Page 11: Asam Tl1 Part 5

1 E1 Commands and Messages

11 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[e1_nblk] An E1 facility parameter block containing one or more of the following named

parameters (separated by commas):

LINETYPE E1 line type. Valid values are:

DSX1E1CRC

DSX1E1

PORTID Port identifier (1...32 characters). Indicates the user to

whom the port is assigned. The following values are

reserved and cannot be used:

AVAILABLE (port is not assigned)

FAILED (port is failed and cannot be assigned)

Also see the RESV�NEXT�PORT and FREE�PORT com�

mands

Page 12: Asam Tl1 Part 5

1 E1 Commands and Messages

12 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[e1_nblk] (cont) The following parameters apply only if the E1 facility directly transports ATM traffic

(ATM mode). For use with IMA, they should be set to null. If no value is specified,

null is assumed.

ATMACCPROF* ATM Access Profile index (1...50). This value deter�

mines the range of values for vpi and vci in several

other commands. The value of ATMACCPROF cannot

be changed while any VPLs or VCLs exist.

ATMACCPROFNM* ATM Access Profile name

CACPROFDN* Connection Admission and Control Profile index for

downstream direction (1...50)

CACPROFDNNM* Connection Admission and Control profile name for

the downstream direction

CACPROFUP* Connection Admission and Control Profile index for

upstream direction (1...50)

CACPROFUPNM* Connection Admission and Control profile name for

the upstream direction

*These parameters should not be used and are only included in this release for

release for backward compatibility, and will not be supported in a later release.

They should be provisioned with the ED�ATMPORT command.

Note: the parameters must have been provisioned using the ENT-IMAGRP and

ED-ATMPORT commands before they can be edited.

QOSCLASS Quality of service of connections on this port. Valid

values are:

CBR (CBR connections only)

UBR (UBR connections only)

CBRUBR (both CBR and UBR connections)

This parameter should not be used and is only included in this release for

backward compatibility. It will be removed from later releases.

[pst] Primary state filter. Valid values are:

IS In�Service

OOS Out�of�Service (OOS�MA is implied)

If no value is specified, this parameter remains unchanged.

Page 13: Asam Tl1 Part 5

Response Format

Example

Related Commands

1 E1 Commands and Messages

13 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* ED-E1:[tid]:aid_e1:[ctag]:::[e1_nblk]:[pst] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* ED-E1:[tid]:aid_e1:[ctag]:::[e1_nblk]:[pst] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Edit circuit 2 on the NT to have a line type of DSX1E1.

ED-E1:RALGH:NTE1-2:42:::LINETYPE=DSX1E1,PORTID=CORWIN;

RALGH 00-11-24 12:30:43M 42 COMPLD /* ED-E1:RALGH:NTE1-2:42:::LIJNETYPE=DSX1E1,PORTID=CORWIN */;

DLT�E1

ENT-E1

RTRV-E1

Page 14: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

14 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1.3 ENT�E1

Creates the provisioning data associated with an E1 facility. It also

provisions any associated direct ATM interface or IMA (Inverse

Multiplexing for ATM) group.

All parameters in this command are position�defined.

A circuit can be used in direct ATM (native) mode only if no IMA

group has been defined for the same port (in other words, circuit

and imagrp cannot have the same value). See ENT�IMAGRP.

ENT-E1:[tid]:aid_e1:[ctag]:::e1_nblk:[pst];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access Identifier for the E1 facility. Enter in one of the following formats, replacing

lower�case parameters with the values given:

LTE1�rack�shelf�lt_slot�circuit

NTE1�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT(1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

e1_nblk E1 facility parameter block containing one or more of the following named

parameters (separated by commas):

LINETYPE Type of line interface used. Valid values are:

DSXE1

DSXE1CRC (default)

PORTID Port identifier (1...32 characters). Indicates the user to

whom the port is assigned. The following values are

reserved and cannot be used:

AVAILABLE (port is not assigned)

FAILED (port is failed and cannot be assigned)

Page 15: Asam Tl1 Part 5

1 E1 Commands and Messages

15 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[e1_nblk] (cont) The following parameters apply only if the E1 facility directly transports ATM traffic

(ATM mode). For use with IMA, they should be set to null. If no value is specified,

null is assumed.

ATMACCPROF* ATM Access Profile index (1...50). This value deter�

mines the range of values for vpi and vci in several

other commands. The value of ATMACCPROF cannot

be changed while any VPLs or VCLs exist.

ATMACCPROFNM* ATM Access Profile name

CACPROFDN* Connection Admission and Control Profile index for

downstream direction (1...50)

CACPROFDNNM* Connection Admission and Control profile name for

the downstream direction

CACPROFUP* Connection Admission and Control Profile index for

upstream direction (1...50)

CACPROFUPNM* Connection Admission and Control profile name for

the upstream direction

*These parameters should not be used and are only included in this release for

release for backward compatibility, and will not be supported in a later release.

They should be provisioned with the ED�ATMPORT command.

Note that the parameters must have been provisioned using the ENT-IMAGRP

and ED-ATMPORT commands before they can be edited.

QOSCLASS Quality of service of connections on this port. Valid

values are:

CBR (CBR connections only)

UBR (UBR connections only)

CBRUBR (both CBR and UBR connections)

This parameter should not be used and is only included in this release for

backward compatibility. It will be removed from later releases.

Page 16: Asam Tl1 Part 5

Response Format

1 E1 Commands and Messages

16 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

The following parameter applies only if the E1 facility is to be used with an IMA

group. For use with ATM, it should be set to null. If no value is specified, null is

assumed.

IMAGRP IMA group to which this facility is to be assigned. Valid

values are:

NTIMA (AID of IMA group on NT)

LTIMA�imagrp (AID of IMA group on LT, imagrp =

1..4)

NULL (Do not use IMA; E1 will directly transport ATM)

Note: If an IMA group is specified, it must exist.

Note: For each profile above, either the profile name or the index (not both) may

be specified. If a profile name is specified and two profiles match the name (one

Local and other Network), the Network profile is used.

The E1-NT or E1-LT may use up to 4 E1 facilities with an IMA Group.

Otherwise only one E1 facility may be used to directly transport ATM.

[pst] Primary state filter. Valid values are:

IS In�Service

OOS Out�of�Service (OOS�MA is implied)

If no value is specified, this parameter remains unchanged.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* ENT-E1:[tid]:aid_e1:[ctag]:::e1_nblk:[pst] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* ENT-E1:[tid]:aid_e1:[ctag]:::e1_nblk:[pst] */ errcde;

Page 17: Asam Tl1 Part 5

Example

Related Commands

1 E1 Commands and Messages

17 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Enter E1 circuit 2�2�10�1 on the LT with a line interface type of

DSX1E1, a port ID of FRANKLIN, and an IMA group of NTIMA.

ENT-E1:RALGH:LTE1-2-2-10-1:42:::LINETYPE=DSX1E1,PORTID=FRANKLIN,IMAGRP=NTIMA;

RALGH 00-11-24 12:30:43M 42 COMPLD /*ENT-E1:RALGH:LTE1-2-2-10-1:42:::LINETYPE=DSX1E1,PORTID=FRANKLIN,IMAGRP=NTIMA */;

FREE�PORT

RESV�NEXT�PORT

RTRV�E1

Page 18: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

18 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1.4 OPR�LPBK�E1

Places the selected E1 facility in a loopback mode.

� All parameters in this command are position�defined.

� Loopbacks are supported for the near end (NEND) of the

facility only.

� Loopbacks provisioned with this command are maintained

persistently.

� The near end of the facility can also be placed in loopback by

sending E1 in�band loopback control codes. This form of

loopback is not maintained persistently.

� Loopbacks provisioned with this command take priority over

in�band loopbacks.

� Only one loopback at a time is allowed on a facility.

OPR-LPBK-E1:[tid]:aid_e1:[ctag]::,,,[lbktype];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access Identifier for the E1 facility. Valid values are:

NTE1�circuit

LTE1�rack�shelf�lt�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

Page 19: Asam Tl1 Part 5

Response Format

1 E1 Commands and Messages

19 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[lpbktype] Type of loopback. Valid values are:

LINE Loopback facility at the physical line level toward the

facility (default)

PAYLOAD Loopback facility data (payload) toward the facility

TERMINAL Loopback facility data internally toward the NE

If not specified, LINE is assumed

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* OPR-LPBK-E1:[tid]:aid_e1:[ctag]::,,,[lpbktype] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* OPR-LPBK-E1:[tid]:aid_e1:[ctag]::,,,[lpbktype] */ errcde /* error description */;

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Page 20: Asam Tl1 Part 5

Example

Related Command

1 E1 Commands and Messages

20 / 166 3EC 36876 AEAA TCZZA Edition 02

Place NTE1 circuit 2 in payload loopback mode.

OPR-LPBK-E1:RALGH:NTE1-2:40::,,,PAYLOAD;

RALGH 00-11-24 12:30:43M 40 COMPLD /* OPR-LPBK-E1:RALGH:NTE1-2:40::,,,PAYLOAD */;

RLS�LPBK�E1

Page 21: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

1 E1 Commands and Messages

21 / 1663EC 36876 AEAA TCZZA Edition 02

1.1.5 REPT�OPSTAT�E1

Reports current operational parameters for E1 lines.

All parameters in this command are position�defined.

REPT-OPSTAT-E1:[tid]:aid_e1:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access identifier for E1 facility. Enter in the following format, replacing lower�case

parameters with the values given:

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* REPT-OPSTAT-E1:[tid]:aid_e1:[ctag][:] */ “aid_e1:op_e1,value”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* REPT-OPSTAT-E1:[tid]:aid_e1:[ctag][:] */ errcde;

Page 22: Asam Tl1 Part 5

Example

Related Commands

1 E1 Commands and Messages

22 / 166 3EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (1...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_e1 As described for command parameters

op_e1 E1 operational parameter. Values are:

INCELLS Rolling count of cells received on this facility

OUTCELLS Rolling count of cells transmitted on this facility

value The value of the parameter specified in op_adsl.

Report E1 operational parameters for rack 2, shelf 3, slot 6,

circuit 1.

REPT-OPSTAT-E1:RALGH:LTE1-2-3-6-1;

RALGH 00-01-24 12:30:43M 42 COMPLD /* REPT-OPSTAT-IMAGRP:RALGH:LTE1-2-3–6-1:42 */ “LTE1-2-3–6-1:INCELLS,36600” “LTE1-2-3–6-1:OUTCELLS,28800”;

None.

Page 23: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

23 / 1663EC 36876 AEAA TCZZA Edition 02

1.1.6 RLS�LPBK�E1

Releases any loopback currently active at the near end of a

specific E1 facility.

All parameters in this command are position�defined.

Provisioned loopbacks (set with the OPR�LPBK�E1 command) and

in�band loopbacks (set by E1 in�band control codes) are both

released.

RLS-LPBK-E1:[tid]:aid_e1:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access identifier for the E1 facility. Valid values are:

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Page 24: Asam Tl1 Part 5

Response Format

Example

Related Command

1 E1 Commands and Messages

24 / 166 3EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RLS-LPBK-E1:[tid]:aid_e1:[ctag][:] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RLS-LPBK-E1:[tid]:aid_e1:[ctag][:] */ errcde /* error description */;

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Release LTE1 circuit 2 from loopback mode.

RLS-LPBK-E1:RALGH:LTE1-2:40;

RALGH 00-11-24 12:30:43M 40 COMPLD /* RLS-LPBK-E1:RALGH:LTE1-2:40 */;

OPR�LPBK�E1

Page 25: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

25 / 1663EC 36876 AEAA TCZZA Edition 02

1.1.7 RTRV�ALM�E1

Retrieves current alarms for selected E1 facilities.

All parameters in this command are position�defined.

RTRV-ALM-E1:[tid]:aid_e1:[ctag]::[ntfcde],,[srveff],[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing

lower�case parameters with the values given:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[ntfncde] Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

Grouping is allowed. If no value is specified, ALL is assumed.

[serveff] Service effect. Valid values are:

SA Service affecting

NSA Not service affecting

Grouping is allowed. If no value is specified, ALL is assumed.

Page 26: Asam Tl1 Part 5

Response Format

1 E1 Commands and Messages

26 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[locn] Location of the condition. Valid values are:

NEND Near end

FEND Far end

If no value is specified, ALL is assumed.

[dirn] Direction of the condition. Valid values are:

RCV Receive

TRMT Transmit

If no value is specified, ALL is assumed.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ALM-E1:[tid]:aid_e1:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ “aid_e1[,aid_type]:ntfncde,cond_e1,serveff,,,[locn],[dirn]:[cond_descr]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ALM-E1:[tid]:aid_e1:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ errcde /* error description */;

Page 27: Asam Tl1 Part 5

Example

Related Commands

1 E1 Commands and Messages

27 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_e1 As described for command parameters, except that ALL is not used

aid_type The type of Access Identifier. The value is E1.

ntfncde As described for command parameters, except that ALL is not used

cond_e1 E1 facility condition. Values are as defined in �E1 Conditions", Section 1.3

serveff As described for command parameters, except that ALL is not used

[locn] As described for command parameters

[dirn] As described for command parameters

[cond_descr] Description of alarm conditionas defined in �E1 Conditions", Section 1.3

Retrieve service�affecting critical alarms for NT circuit 2.

RTRV-ALM-E1:RALGH:NTE1-2:42::CR,,SA;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-ALM-E1:RALGH:NTE1-2:42::CR::SA */ “NTE1-2,E1:CR,LOS,SA,,,NEND,RCV,:Loss of Signal/Clock”;

None

Page 28: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

28 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1.8 RTRV�ATTR�E1

Retrieves current attributes of E1 facility�related conditions.

All parameters in this command are position�defined.

RTRV-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::[ntfcde],[cond_e1],[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

[aid_all_e1] Access identifier for the all E1 facilities. The value is E1.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[ntfncde] Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NA Not alarmed (reported via REPORT EVENT)

NR Not reported (information is stored in the NE)

Grouping is allowed. If no value is specified, ALL is assumed.

[cond_e1] E1 facility condition. Valid values are described �E1 Conditions", Section 1.3

[locn] Facility location. Valid values are:

NEND Near end

FEND Far end

Only applicable to conditions supporting location. If no value is specified, ALL is

assumed.

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

Only applicable to conditions supporting direction. If no value is specified, ALL is

assumed.

Page 29: Asam Tl1 Part 5

Response Format

Example

Related Commands

1 E1 Commands and Messages

29 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ATTR-E1:[tid]:[aidall_e1]:[ctag]::[ntfncde],[cond_e1],[locn],[dirn]*/ “aid_all_e1[,aid_type]:ntfncde,cond_e1,[locn],[dirn]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ATTR-E1:[tid]:aidall_e1:[ctag]::[ntfncde],[cond_e1],[locn],[dirn] */ errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_all_e1 As described for command parameters, except that ALL is not used

aid_type The type of Access Identifier. The value is E1.

[ntfncde] As described for command parameters, except that ALL is not used

[cond_e1] As described for command parameters

[locn] As described for command parameters

[dirn] As described for command parameters

Retrieve critical attributes for E1 conditions.

RTRV-ATTR-E1:RALGH:E1:42::CR;

RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-ATTR-E1:RALGH:E1:42::CR */ “E1,E1:CR,LOF,NEND,RCV”;

SET�ATTR�E1

Page 30: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

30 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1.9 RTRV�COND�E1

Retrieves current conditions of an E1 facility.

All parameters in this command are position�defined.

RTRV-COND-E1:[tid]:aid_e1:[ctag]::[cond_e1],[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access identifier for the E1 facility. Valid values are:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt�slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3

[locn] Facility location. Valid values are:

NEND Near end

FEND Far end

If no value is specified, ALL is assumed.

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

If no value is specified, ALL is assumed.

Page 31: Asam Tl1 Part 5

Response Format

1 E1 Commands and Messages

31 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-COND-E1:[tid]:aid_e1:[ctag]::[cond_e1],[locn],[dirn] */ “aid_e1[,aid_type]:ntfncde,cond_e1,serveff,,,[locn],[dirn],,[cond_descr]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-COND-E1:[tid]:aid_e1:[ctag]::[cond_ds1],[locn] */ errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_e1 As described for command parameters

[aid_type] The type of Access Identifier. The value is E1.

ntfncde Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NA Not alarmed (reported via REPORT EVENT)

NR Not reported (information is stored in the NE)

cond_e1 As described for command parameters, except that ALL is not used

serveff Service effect. Valid values are:

SA Service affecting

NSA Not service affecting

[locn] As described for command parameters, except that ALL is not used

[dirn] As described for command parameters, except that ALL is not used

[cond_descr] Description of alarm condition.

Page 32: Asam Tl1 Part 5

Example

Related Commands

1 E1 Commands and Messages

32 / 166 3EC 36876 AEAA TCZZA Edition 02

Retrieve current conditions for NT circuit 2 facility.

RTRV-COND-E1:RALGH:NTE1-2:42::,,;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-COND-E1:RALGH:NTE1-2:42::,, */ “NTE1-2,E1:CR,LOS,SA,,,NEND,RCV,,Loss Of Signal/Clock”;

None

Page 33: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

33 / 1663EC 36876 AEAA TCZZA Edition 02

1.1.10 RTRV�PM�E1

Retrieves E1 performance monitoring data.

All parameters in this command are position�defined.

RTRV-PM-E1:[tid]:aid_e1:[ctag]::[mone1],[monlev],[locn],[dirn],[tmper],[mondat],[montm];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access identifier for the environment. Valid values are:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[mone1] Monitored parameter (Monotype). Valid values are given in �E1 Monotypes,

Section 1.4

[monlev] Threshold level. Enter in the following format:

lev�dirn

lev Level (0...4294967295)

dirn Direction. Valid values are:

UP (Up)

DN (Down)

If no value is specified, 1�UP is assumed.

[locn] Location of the facility. Valid values are:

NEND Near end

FEND Far end

If no value is specified, this parameter is not used for filtering responses.

Page 34: Asam Tl1 Part 5

Response Format

1 E1 Commands and Messages

34 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

If no value is specified, this parameter is not used for filtering responses.

[tmper] Time period. The only valid value is:

15�MIN 15 minutes

If no value is specified, 15�MIN is assumed.

[mondat] Start date for the monitoring period. Valid values are:

mm�dd Month and day

mm Month (1...12)

dd Day (1...31)

ALL All performance monitoring data is retrieved

If no value is specified, today's date is assumed.

[montm] Start time for the monitoring period. Valid values are:

hh�mm Hour and minute

hh Hour (00...23)

mm Minute. Valid values are 0, 15, 30, and 45.

ALL All performance monitoring data is retrieved

If no value is specified, the nearest value to the current time is assumed. Grouping

is allowed.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-PM-E1:[tid]:aid_e1:[ctag]::[mone1],[monlev],[locn],[dirn],[tmper], [mondat],[montm] */ “aid_e1[,aid_type]:mone1,monval,,[locn],,[tmper],[mondat],[montm]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-PM-E1:[tid]:aid_e1:[ctag]::[mone1],[monlev],[locn],[dirn],[tmper], [mondat],[montm] */ errcde;

Page 35: Asam Tl1 Part 5

Example

Related Command

1 E1 Commands and Messages

35 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

aid_e1 As described for command parameters

[aid_type] Type of AID. The value is E1.

mone1 As described for command parameters, except that ALL is not used

monval Measured value for the monitored parameter (0...4294967295)

[locn] As described for command parameters

[dirn] As described for command parameters

[tmper] As described for command parameters

[mondat] As described for command parameters, except that ALL is not used

[montm] As described for command parameters, except that ALL is not used

errcde Error code (See Appendix B)

Retrieve the near�end alarm indication signal count above 4096

for a 15�minute period beginning at 8:30 a.m. on November 10.

RTRV-PM-E1:RALGH:NTE1-3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-PM-E1:RALGH:NTE1-3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30 */ “NTE1-3:CV-L,2015,,NEND,,15-MIN,11-10,08-30”;

RTRV�ALM�E1

Page 36: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

36 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1.11 RTRV�E1

Retrieves the provisioning data associated with an E1 facilities.

All parameters in this command are position�defined.

RTRV-E1:[tid]:aid_e1:[ctag]::::[pstf],[sstf];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing

lower�case parameters with the values given:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

Grouping and ranging are allowed.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[pstf] Primary state filter. Valid values are:

IS In�Service

OOS Out�of�Service (OOS�MA, OOS�AU, OOS�AUMA)

AU OOS�AU, OOS�AUMA

MA OOS�MA, OOS�AUMA

If no value is specified, this filter is ignored.

[sstf] Secondary state filter. Valid values are:

LPBK Retrieve looped�back entities only

If no value is specified, this filter is ignored.

Page 37: Asam Tl1 Part 5

Response Format

1 E1 Commands and Messages

37 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-E1:[tid]:aid_e1:[ctag]::::[pstf],[sstf] */ aid_e1::e1_nblk:state,[sst];

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-E1:[tid]:aid_e1:[ctag]::::[pstf],[sstf] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

aid_e1 As described for command parameters

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

e1_nblk E1 facility parameter block containing one or more of the following named

parameters (separated by commas):

LINETYPE Type of line interface used. Values are:

DSX1E1

DSX1E1CRC

PORTID Port identifier (1...32 characters). Indicates the user to

whom the port is assigned. The following values are

reserved and cannot be used:

AVAILABLE (port is not assigned)

FAILED (port has failed and cannot be assigned)

Page 38: Asam Tl1 Part 5

1 E1 Commands and Messages

38 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

e1_nblk

(cont)

The following parameters apply only if the E1 facility directly transports ATM traffic

(ATM mode). For each profile, either the profile name or the profile index (not

both) can be specified. If a profile name matches two profiles (Network and Lo�

cal), the Network profile is used.

ATMACCPROF* ATM Access Profile index (1...50). Default is 1.

ATMACCPROFNM* ATM Access Profile name

CACPROFDN* Connection Admission and Control Profile index for

downstream direction (1...50). Default is 1.

CACPROFDNNM* Connection Admission and Control Profile name for

the downstream direction

CACPROFUP* Connection Admission and Control Profile index for

upstream direction (1...50). Default is 1.

CACPROFUPNM* Connection Admission and Control Profile name for

the upstream direction

*These parameters should not be used and are only included in this release for

release for backward compatibility, and will not be supported in a later release.

They should be provisioned with the ED�ATMPORT command.

QOSCLASS Quality of service of connections on this port. Valid

values are:

CBR (CBR connections only)

UBR (UBR connections only)

CBRUBR (both CBR and UBR connections)

This parameter should not be used and is only included in this release for

backward compatibility. It will be removed from later releases.

The following parameter applies only if the E1 facility is to be used with an IMA

group. Otherwise it is not reported.

IMAGRP IMA group to which this facility is to be assigned.

Values are:

NTIMA (AID of IMA group on NT)

LTIMA�imagrp (AID of IMA group on LT, imagr=1..4)

NULL (Do not use IMA; E1 will directly transport ATM)

pst Primary state. Values are:

IS�NR

OOS�AU

OOS�MA (Transient state. Changes to OOS-AUMA

OOS�AUMA

[sst] Secondary state. Values are:

LPBK Retrieve looped�back entities only

errcde Error code (See Appendix B)

Page 39: Asam Tl1 Part 5

Example

Related Commands

1 E1 Commands and Messages

39 / 1663EC 36876 AEAA TCZZA Edition 02

Retrieve circuit 2 on the NT.

RTRV-E1:RALGH:NTE1-2:42::::;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-E1:RALGH:NTE1-2:42:::: */ NTE1-2::LINETYPE=DSX1E1,CACPROFDN=4,CACPROFUP=3,ATMACCPROF=9,IMAGRP=2:IS-NR,;

ENT�E1

Page 40: Asam Tl1 Part 5

Function

Restrictions

Command Format

1 E1 Commands and Messages

40 / 166 3EC 36876 AEAA TCZZA Edition 02

1.1.12 SET�ATTR�E1

Sets attributes of E1 facility�related alarm conditions.

All parameters in this command are position�defined.

Attributes are common for all E1 facilities.

SET-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::ntfncde,cond_e1,[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NE's SID code is the only other valid value.

[aid_all_e1] Access identifier for all E1 facilities. The value is E1.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

ntfncde Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NA Not alarmed (reported via REPORT EVENT)

NR Not reported (information is stored in the NE)

[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3

[locn] Facility location. Valid values are:

NEND Near end

FEND Far end

Only applicable to conditions supporting location. If no value is

specified, ALL is assumed.

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

Only applicable to conditions supporting direction. If no value is

specified, ALL is assumed.

Page 41: Asam Tl1 Part 5

Response Format

Example

Related Command

1 E1 Commands and Messages

41 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::ntfncde,cond_e1,[locn],[dirn] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* SET-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::ntfncde,cond_e1,[locn],[dirn] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Associate the critical (CR) notification code with the RAI alarm

condition.

SET-ATTR-E1:RALGH:E1:42::CR,RAI;

RALGH 98-11-24 12:30:43M 42 COMPLD /* SET-ATTR-E1:RALGH:E1:42::CR,RAI */;

RTRV�ATTR�E1

Page 42: Asam Tl1 Part 5

Function

Message Format

1 E1 Commands and Messages

42 / 166 3EC 36876 AEAA TCZZA Edition 02

1.2 E1 Autonomouse Messages

This section describes the E1 autonomous messages.

1.2.1 REPT ALM E1

Reports current E1 facility alarms from the NE.

almcode atag REPT ALM E1 “aid_e1:ntfncde,cond_e1,serveff,[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;

Response Parameters

Parameter Explanation

almcde Alarm code. Identifies the severity of the alarm. Values are:

*C Critical alarm

** Major alarm

*^ Minor alarm

A^ Automatic message (typically used to report a cleared

alarm)

atag Automatic tag that indicates the numerical sequence of messages reported

aid_e1 Access identifier for the E1 facility. Values are:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

ntfncde Notification code. Values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

CL Cleared alarm

[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3

serveff Service effect. Values are:

SA Service affecting

NSA Not service affecting

Page 43: Asam Tl1 Part 5

1 E1 Commands and Messages

43 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[ocrdat] Date of occurrence in the following format:

mm�dd Month and day

mm Month (1...12)

dd Day (1...31)

[ocrtm] Time of occurrence in the following format:

hh�mm�ss Hour, minute, and second

hh Hour (00...23)

mm Minute (00...59)

ss Second (00...59)

[locn] Location of the condition. Values are:

NEND Near end

FEND Far end

[dirn] Direction of the condition. Values are:

RCV Receive

TRMT Transmit

[conddescr] Text string of up to 40 characters that describes the alarm condition

Page 44: Asam Tl1 Part 5

Function

Message Format

1 E1 Commands and Messages

44 / 166 3EC 36876 AEAA TCZZA Edition 02

1.2.2 REPT EVT E1

Reports current E1 facility events from the NE.

almcode atag REPT EVT E1 “aid_e1:cond_e1,[condeff],[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;

Response Parameters

Parameter Explanation

almcde Alarm code. Identifies the severity of the alarm. Values are:

A^ Non�alarm message

atag Automatic tag that indicates the numerical sequence of messages reported

aid_e1 Access identifier for the E1 facility. Values are:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

circuit Circuit in the NT or LT (1...4)

[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3

[condeff] Effect of the event on the condition reported. Values are:

SC Standing condition raised

CL Standing condition cleared

TC Transient condition

[ocrdat] Date of occurrence in the following format:

mm�dd Month and day

mm Month (1...12)

dd Day (1...31)

[ocrtm] Time of occurrence in the following format:

hh�mm�ss Hour, minute, and second

hh Hour (00...23)

mm Minute (00...59)

ss Second (00...59)

Page 45: Asam Tl1 Part 5

1 E1 Commands and Messages

45 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[locn] Location of the condition. Values are:

NEND Near end

FEND Far end

[dirn] Direction of the condition. Values are:

RCV Receive

TRMT Transmit

[cond_descr] Text string of up to 40 characters that describes the alarm condition

Page 46: Asam Tl1 Part 5

1 E1 Commands and Messages

46 / 166 3EC 36876 AEAA TCZZA Edition 02

1.3 E1 Conditions

Table 1 lists the E1 conditions. In this table, [L] indicates conditions

that support the 'Location' parameter and [D] indicates conditions

that support the 'Direction' parameter

Table 1 E1 Conditions

Condition SERVEFF DEF NTFCNCDE Description

RAI SA Minor Remote Alarm Indication.[L] [D]

AIS SA Minor Alarm Indication Signal.[L] [D]

LOF SA MAJOR Loss of framing.[L] [D]

LOS SA Minor Loss of Signal/Clock.[L] [D]

ACTLPBK SA Minor Facility placed in loopback.[L]

MISMATCH SA Minor Interface does not match configuration.[L]

LCD* SA Minor Loss of ATM Cell Delineation.[L] [D]

LI F+ SA Minor Loss of IMA Frame.[L] [D]

LODS+ SA Minor IMA Link out of Delay Synchronization.[L] [D]

MISCONN+ SA Minor IMA Link Mis-connected.[L] [D]

RFI-IMA+ SA Minor IMA Remote Failure Indication.[L] [D]

FAULT-IMA+ SA Minor IMA Remote Failure Indication.[L] [D]

UNUSABLE�IMA+ SA Minor IMA Link unusable due to far-end behavior.[L] [D]

* These ATM Conditions are only available as "E1 Conditions" in this release for backward compatibility,

and will be removed in a future release They should be retrieved via xxx-ATMPORT commands.

+ IMA Link conditions reported via the E1 facility (For E1's being used as a Link with IMA).

Note DS1 and E1 facilities share alarm conditions. Attribute

changes affect both type of facilities.

Page 47: Asam Tl1 Part 5

1 E1 Commands and Messages

47 / 1663EC 36876 AEAA TCZZA Edition 02

1.4 E1 Monotypes

Table 2 lists the E1 Monotypes. In this table, the following

notations are used:

� Location:

� NE = Near�end of the facility

� FE = Far�end of the facility

� Direction

� RX = Receive

� TX = Transmit.

Table 2 E1 Monotypes

Monotype Location Direction Description

CV-L NE Rx Line Code Violations

ES-L NE + FE Rx Line Errored Seconds

CV-P NE + FE Rx Path Coding Violations

ES-P NE + FE Rx Path Errored Seconds

ESB-P NE + FE Rx Path Errored Seconds - Type B

SES-P NE + FE Rx Path Severely Errored Seconds

UAS-P NE +FE Rx Path Un-Available Seconds

SEFS-P NE + FE Rx Path Severely Errored Framing Seconds

DHECV* NE Rx Discarded Cells Due to HEC Violation

IV-IMA-L+ NE Rx IMA Link ICP Violations

SES-IMA-L+ NE + FE Rx IMA Link Severely Errored Seconds

UAS-IMA-L+ NE + FE Rx IMA Link Un-Available Seconds

UUS-IMA-L+ NE + FE Tx + Rx IMA Link Un-Usable Seconds

FC-IMA-L+ NE + FE Tx + Rx IMA Link Failure Count

OIF-IMA-L+ NE Rx IMA Link Out of IMA Frame Events

STUFF-IMA-L+ NE Rx IMA Link ICP Cell Stuffing Events

* These ATM Montypes are only available as "E1 Montypes" in this release for backward compatibility, and

will be removed in a future release They should be retrieved via xxx-ATMPORT commands.

+ These IMA Link parameters are reported via the underlying E1 facility if it is used as an IMA Link.

Page 48: Asam Tl1 Part 5

1 E1 Commands and Messages

48 / 166 3EC 36876 AEAA TCZZA Edition 02

Page 49: Asam Tl1 Part 5

2 E3 Commands and Messages

49 / 1663EC 36876 AEAA TCZZA Edition 02

2 E3 Commands and Messages

This chapter provides information about the E3 commands and

messages. The chapter has the following main parts:

� E3 Commands

� E3 Autonomous Messages.

� E3 Conditions

� E3 Monotypes.

Page 50: Asam Tl1 Part 5

Function

Restrictions

Command Format

2 E3 Commands and Messages

50 / 166 3EC 36876 AEAA TCZZA Edition 02

2.1 E3 Commands

This section describes the E3 commands.

2.1.1 ED�E3

Edits the provisioning data associated with an E3 facility.

All parameters in this command are position�defined.

ED-E3:[tid]:aid_e3:[ctag]:::[e3_nblk]:[pst];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID

code is the only other valid value.

aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this

is not required. Valid values are:

NTE3�circuit (E3 Facility on the NT sides A and B)

LTE3�rack�shelf�lt_slot�circuit (E3 facility in the LT)

rack Rack number (1...6)

shelf Shelf number (1...2)

lt_slot LT slot number (1...16)

circuit Circuit in the LT (1...4)

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Page 51: Asam Tl1 Part 5

Response Format

2 E3 Commands and Messages

51 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[e3_nblk] Named parameter block for E3. The block consists of one or more of the

following parameters, in any order separated by commas, each followed by an

equal sign and a valid value. If not specified, the values of these parameters

remain unchanged.

ATM access profiles cannot be changed while any VPLs or VCLs exist. The profile

index and profile name for the same entity cannot be specified. If a profile name

matches two profiles (Local and Network), the Network profile is used.

ATMACCPROF* ATM Access Profile index (1...50). This value deter�

mines the range of values for vpi and vci in several

other commands. The value of ATMACCPROF cannot

be changed while any VPLs or VCLs exist.

ATMACCPROFNM* ATM Access Profile name

CACPROFDN* Connection Admission and Control Profile index for

downstream direction (1...50)

CACPROFDNNM* Connection Admission and Control profile name for

the downstream direction

CACPROFUP* Connection Admission and Control Profile index for

upstream direction (1...50)

CACPROFUPNM* Connection Admission and Control profile name for

the upstream direction

*These parameters should not be used and are only included in this release for

release for backward compatibility, and will not be supported in a later release.

They should be provisioned with the ED�ATMPORT command.

[pst] Primary state to be set. Valid values are:

IS In�Service

OOS Out�of�Service (OOS�MA is implied)

If no value is specified, the value of this parameter stays unchanged.

This parameter is not used for the NT

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* ED-E3:[tid]:aid_e3:[ctag]:::[e3_nblk]:[pst] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* ED-E3:[tid]:aid_e3:[ctag]:::[e3_nblk]:[pst] */ aid:ERRCDE=errcde /* error description */;

Page 52: Asam Tl1 Part 5

Example

Related Commands

2 E3 Commands and Messages

52 / 166 3EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

Edit circuit 2 on the NT to use a Connection Admission and

Control Profile index of 9.

ED-E3:RALGH:NTE3:42:::CACPROFUP=9;

RALGH 00-11-24 12:30:43M 42 COMPLD /* ED-E3:RALGH:NTE3:42:::CACPROFUP=9 */;

DLT�E3

RTRV E3

Page 53: Asam Tl1 Part 5

Function

Restrictions

Command Format

2 E3 Commands and Messages

53 / 1663EC 36876 AEAA TCZZA Edition 02

2.1.2 RTRV�ALM�E3

Retrieves current alarms for selected E3 facilities.

All parameters in this command are position�defined.

RTRV-ALM-E3:[tid]:aid_e3:[ctag]::[ntfcde],,[srveff],[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this

is not required. Valid values are:

NTE3 (E3 Facility on the NT sides A and B)

NTE3A (E3 Facility on the NT side A)

NTE3B (E3 Facility on the NT side B)

LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)

rack Rack number (1...6)

shelf Shelf number (1...2)

lt_slot LT slot number (1...16)

circuit Circuit in the LT (1...1)

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

[ntfncde] Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

Grouping is allowed. If no value is specified, ALL is assumed.

[serveff] Service effecting Valid values are:

SA Service affecting

NSA Not service affecting

Grouping is allowed. If no value is specified, ALL is assumed.

Page 54: Asam Tl1 Part 5

Response Format

2 E3 Commands and Messages

54 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[locn] Location of the condition. Valid values are:

NEND Near end

FEND Far end

If no value is specified, ALL is assumed.

[dirn] Direction of the condition. Valid values are:

RCV Receive

TRMT Transmit

If no value is specified, ALL is assumed.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ALM-E3:[tid]:aid_e3:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ “aid_e3[,aid_type]:ntfncde,cond_e3,serveff,,,[locn],[dirn],,[cond_descr]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ALM-E3:[tid]:aid_e3:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_e3 Only E3NTA is supported.

aid_type The type of Access Identifier. The value is E3.

ntfncde As described for command parameters, except that ALL is not used

Page 55: Asam Tl1 Part 5

Example

Related Commands

2 E3 Commands and Messages

55 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3

serveff As described for command parameters, except that ALL is not used

[locn] As described for command parameters

[dirn] As described for command parameters

[cond_descr] Description of alarm condition as defined in �E3 Conditions", Section 2.3

Retrieve service�affecting critical alarms for NT circuit 2.

RTRV-ALM-E3:RALGH:NTE3-2:42::CR,,SA;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-ALM-E3:RALGH:NTE3-2:42::CR::SA */ “NTE3-2,E3:CR,LOS,SA,,,NEND,RCV,:Loss of Signal/Clock”;

None

Page 56: Asam Tl1 Part 5

Function

Restrictions

Command Format

2 E3 Commands and Messages

56 / 166 3EC 36876 AEAA TCZZA Edition 02

2.1.3 RTRV�ATTR�E3

Retrieves current attributes of E3 facility�related conditions.

All parameters in this command are position�defined.

RTRV-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::[ntfcde],[cond_e3],[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

[aidall_e3] Access identifier for all E3 facilities. The value is E3.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

[ntfncde] Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NA Not alarmed (reported via REPORT EVENT)

NR Not reported (information is stored in the NE)

Grouping is allowed. If no value is specified, ALL is assumed.

cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3

[locn] Facility location. Valid values are:

NEND Near end

FEND Far end

Only applicable to conditions supporting location. If no value is specified, ALL is

assumed.

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

Only applicable to conditions supporting direction. If no value is specified, ALL is

assumed.

Page 57: Asam Tl1 Part 5

Response Format

2 E3 Commands and Messages

57 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::[ntfncde],[cond_e3],[locn],[dirn]*/ “aidall_e3[,aid_type]:ntfncde,cond_e3,[locn],[dirn]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::[ntfncde],[cond_e3],[locn],[dirn]*/ errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

aidall_e3 As described for command parameters, except that ALL is not used

aid_type Type of Access Identifier. The value is E3.

[ntfncde] As described for command parameters, except that ALL is not used

[cond_e3] As defined in �E3 Conditions", Section 2.3

[locn] As described for command parameters

[dirn] As described for command parameters

[cond_descr] Description of alarm condition as defined in �E3 Conditions", Section 2.3

Page 58: Asam Tl1 Part 5

Example

Related Commands

2 E3 Commands and Messages

58 / 166 3EC 36876 AEAA TCZZA Edition 02

Retrieve critical attributes for E3 conditions.

RTRV-ATTR-E3:RALGH:E3:42::CR;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-ATTR-E3:RALGH:E3:42::CR */ “E3,E3:CR,LOF,NEND,RCV”;

SET�ATTR�E3

Page 59: Asam Tl1 Part 5

Function

Restrictions

Command Format

2 E3 Commands and Messages

59 / 1663EC 36876 AEAA TCZZA Edition 02

2.1.4 RTRV�COND�E3

Retrieves current conditions of an E3 facility.

All parameters in this command are position�defined.

RTRV-COND-E3:[tid]:aid_e3:[ctag]::[cond_e3],[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this

is not required. Valid values are:

NTE3 (E3 Facility on the NT sides A and B)

NTE3A (E3 Facility on the NT side A)

NTE3B (E3 Facility on the NT side B)

LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)

rack Rack number (1...6)

shelf Shelf number (1...2)

lt_slot LT slot number (1...16)

circuit Circuit in the LT (1...1)

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3

[locn] Facility location. Valid values are:

NEND Near end

FEND Far end

If no value is specified, ALL is assumed.

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

If no value is specified, ALL is assumed.

Page 60: Asam Tl1 Part 5

Response Format

2 E3 Commands and Messages

60 / 166 3EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-COND-E3:[tid]:aid_e3:[ctag]::[cond_e3],[locn],[dirn] */ “aid_e3[,aid_type]:ntfncde,cond_e3,serveff,,,[locn],[dirn],,[cond_descr]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-COND-E3:[tid]:aid_e3:[ctag]::[cond_e3],[locn],[dirn] */ errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

aid_e3 As described for command parameters

[aid_type] Type of Access Identifier. The value is E3.

ntfncde Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NA Not alarmed (reported via REPORT EVENT)

NR Not reported (information is stored in the NE)

cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3

serveff Service effecting Valid values are:

SA Service affecting

NSA Not service affecting

[locn] As described for command parameters, except that ALL is not used

[dirn] As described for command parameters, except that ALL is not used

[cond_descr] Description of alarm condition as defined in �E3 Conditions", Section 2.3

Page 61: Asam Tl1 Part 5

Example

Related Commands

2 E3 Commands and Messages

61 / 1663EC 36876 AEAA TCZZA Edition 02

Retrieve current conditions for NT circuit 2 facility.

RTRV-COND-E3:RALGH:NTE3-2:42::,,;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-COND-E3:RALGH:NTE3-2:42::,, */ “NTE3-2,E3:CR,LOS,SA,,,NEND,RCV,,Loss Of Signal/Clock”;

None

Page 62: Asam Tl1 Part 5

Function

Restrictions

Command Format

2 E3 Commands and Messages

62 / 166 3EC 36876 AEAA TCZZA Edition 02

2.1.5 RTRV�PM�E3

Retrieves E3 performance monitoring data.

All parameters in this command are position�defined.

RTRV-PM-E3:[tid]:aid_e3:[ctag]::[mone3],[monlev],[locn],[dirn],[tmper],[mondat],[montm];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this

is not required. Valid values are:

NTE3 (E3 Facility on the NT sides A and B)

NTE3A (E3 Facility on the NT side A )

NTE3B (E3 Facility on the NT side B)

LTE3�rack�shelf�lt_slot�circuit (E3 facility in the LT side)

rack Rack number (1...6)

shelf Shelf number (1...2)

lt_slot LT slot number (1...16)

circuit Circuit number (1...1)

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

[mone3] E3 monitored parameter. Valid values are as defined in �E3 Monotypes", section

2.4.

Grouping is allowed. If no value is specified, ALL is assumed.

[monlev] Threshold level. Enter in the following format:

lev�dirn

lev Level (0...4294967295)

dirn Direction. Valid values are:

UP (Up)

DN (Down)

If no value is specified, 1�UP is assumed.

Page 63: Asam Tl1 Part 5

Response Format

2 E3 Commands and Messages

63 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[locn] Location of the facility. Valid values are:

NEND Near end

FEND Far end

If no value is specified, all values are reported.

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

If no value is specified, this parameter is not used for filtering responses.

[tmper] Time period. The only valid value is:

15�MIN 15 minutes

If no value is specified, 15�MIN is assumed.

[mondat] Start date for the monitoring period. Valid values are:

mm�dd Month and day

mm Month (1...12)

dd Day (1...31)

ALL All performance monitoring data is retrieved

If no value is specified, today's date is assumed.

[montm] Start time for the monitoring period. Valid values are:

hh�mm Hour and minute

hh Hour (00...23)

mm Minute. Valid values are 0, 15, 30, and 45.

ALL All performance monitoring data is retrieved

Grouping is allowed. If no value is specified, the nearest value to the current time

is assumed.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-PM-E3:[tid]:aid_e3:[ctag]::[mone3],[monlev],[locn],[dirn],[tmper], [mondat],[montm] */ “aid_e3[,aid_type]:mone3,monval,,[locn],,[tmper],[mondat],[montm]”;

Page 64: Asam Tl1 Part 5

Example

Related Command

2 E3 Commands and Messages

64 / 166 3EC 36876 AEAA TCZZA Edition 02

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-PM-E3:[tid]:aid_e3:[ctag]::[mone3],[monlev],[locn][dirn],[tmper], [mondat],[montm] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

aid_e3 As described for command parameters

[aid_type] Type of AID. The value is E3.

mone3 As described for command parameters, except that ALL is not used

monval Measured value for the monitored parameter (0...4294967295)

[locn] As described for command parameters

[dirn] As described for command parameters

[tmper] As described for command parameters

[mondat] As described for command parameters, except that ALL is not used

[montm] As described for command parameters, except that ALL is not used

errcde Error code (see Appendix B)

Retrieve the near�end line code violation count above 4096 for a

15�minute period beginning at 8:30 a.m. on November 10.

RTRV-PM-E3:RALGH:NTE3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-PM-E3:RALGH:NTE3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30 */ “NTE3:CV-L,2015,,NEND,,15-MIN,11-10,08-30”;

RTRV�ALM�E3

Page 65: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

2 E3 Commands and Messages

65 / 1663EC 36876 AEAA TCZZA Edition 02

2.1.6 RTRV�E3

Retrieves the provisioning data associated with an E3 facilities.

All parameters in this command are position�defined.

RTRV-E3:[tid]:aid_e3:[ctag]::::[pstf];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this

is not required. Valid values are:

NTE3 (E3 Facility on the NT sides A and B)

NTE3A (E3 Facility on the NT side A)

NTE3B (E3 Facility on the NT side B)

LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)

rack Rack number (1...6)

shelf Shelf number (1...2)

lt_slot LT slot number (1...16)

circuit Circuit number (1...1)

[pstf] Primary state filter. Valid values are:

IS In�Service

OOS Out�of�Service (OOS�MA, OOS�AU, OOS�AUMA)

AU OOS�AU, OOS�AUMA

MA OOS�MA, OOS�AUMA

If no value is specified, this filter is ignored.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-E3:[tid]:aid_e3:[ctag]::::[pstf] */ aide3::e3_nblk:state;

Page 66: Asam Tl1 Part 5

2 E3 Commands and Messages

66 / 166 3EC 36876 AEAA TCZZA Edition 02

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-E3:[tid]:aid_e3:[ctag]::::[pstf] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

aid_e3 As described for command parameters

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

[e3_nblk] Named parameter block for E3. The block consists of the following parameters,

each followed by an equal sign and a value.

ATMACCPROF* ATM Access Profile index (1...50). Default is 1.

ATMACCPROFNM* ATM Access Profile name

CACPROFDN* Connection Admission and Control Profile index for

downstream direction (1...50). Default is 1.

CACPROFDNNM* Connection Admission and Control Profile name for

the downstream direction

CACPROFUP* Connection Admission and Control Profile index for

upstream direction (1...50). Default is 1.

CACPROFUPNM* Connection Admission and Control Profile name for

the upstream direction

*These parameters should not be used and are only included in this release for

release for backward compatibility, and will not be supported in a later release.

They should be provisioned with the ED�ATMPORT command.

state Primary state. Values are:

IS�NR

OOS�AU

OOS�MA (Transient state. Changes to OOS-AUMA)

OOS�AUMA

errcde Error code (see Appendix B)

Page 67: Asam Tl1 Part 5

Example

Related Command

2 E3 Commands and Messages

67 / 1663EC 36876 AEAA TCZZA Edition 02

Retrieve E3 provisioning data.

RTRV-E3:RALGH:NTE3:42;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-E3:RALGH:NTE3:42 */ NTE3::CELLMAPNG=PLCP_SCRAM,CRDECPLNG=IDLE,OOFDETECT=3OF16BITS, LINEBLDOUT=ENABLED,CACPROFUP=14,ATMACCPROF=9:IS-NR;

ENT�E3

Page 68: Asam Tl1 Part 5

Function

Restrictions

Command Format

2 E3 Commands and Messages

68 / 166 3EC 36876 AEAA TCZZA Edition 02

2.1.7 SET�ATTR�E3

Sets attributes of E3 facility�related alarm conditions. Attributes are

common for all E3 facilities.

All parameters in this command are position�defined.

SET-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::ntfncde,cond_e3,[locn],[dirn];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NE's SID code is the only other valid value.

[aid_all_e3] Access identifier for all E3 facilities. The value is E3.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

ntfncde Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NA Not alarmed (reported via REPORT EVENT)

NR Not reported (information is stored in the NE)

cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3

[locn] Facility location. Valid values are:

NEND Near end

FEND Far end

Only applicable to conditions supporting location. If no value is specified, ALL is

assumed.

[dirn] Signal direction. Valid values are:

RCV Receive

TRMT Transmit

Only applicable to conditions supporting direction. If no value is specified, ALL is

assumed.

Page 69: Asam Tl1 Part 5

Response Format

Example

Related Command

2 E3 Commands and Messages

69 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::ntfncde,cond_e3,[locn],[dirn] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* SET-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::ntfncde,cond_e3,[locn],[dirn] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

Associate the critical (CR) notification code with the RAI alarm

condition.

SET-ATTR-E3:RALGH:E3:42::CR,RAI;

RALGH 00-11-24 12:30:43M 42 COMPLD /* SET-ATTR-E3:RALGH:E3:42::CR,RAI */;

RTRV�ATTR�E3

Page 70: Asam Tl1 Part 5

Function

Message Format

2 E3 Commands and Messages

70 / 166 3EC 36876 AEAA TCZZA Edition 02

2.2 E3 Autonmous Messages

This section describes the E3 autonomous messages.

2.2.1 REPT ALM E3

Reports current E3 facility alarms from the NE.

almcode atag REPT ALM E3 “aid_e3:ntfncde,cond_e3,serveff,[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;

Response Parameters

Parameter Explanation

almcde Alarm code. Identifies the severity of the alarm. Values are:

*C Critical alarm

** Major alarm

*^ Minor alarm

A^ Automatic message (typically used to report a cleared

alarm)

atag Automatic tag that indicates the numerical sequence of messages reported

aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this

is not required. Valid values are:

NTE3 (E3 Facility on the NT sides A and B)

NTE3A (E3 Facility on the NT side A)

NTE3B (E3 Facility on the NT side B)

LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)

rack Rack number (1...6)

shelf Shelf number (1...2)

lt_slot LT slot number (1...16)

circuit Circuit number (1...1)

ntfncde Notification code. Values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

CL Cleared alarm

cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3

Page 71: Asam Tl1 Part 5

2 E3 Commands and Messages

71 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

serveff Service effecting Values are:

SA Service affecting (Immediate action required)

NSA Not service affecting

[ocrdat] Date of occurrence in the following format:

mm�dd Month and day

mm Month (1...12)

dd Day (1...31)

[ocrtm] Time of occurrence in the following format:

hh�mm�ss Hour, minute, and second

hh Hour (00...23)

mm Minute (00...59)

ss Second (00...59)

[locn] Location of condition. Values are:

NEND Near end

FEND Far end

[dirn] Direction of condition. Values are:

RCV Receive

TRMT Transmit

[conddescr] Description of condition (1...40 characters)

Page 72: Asam Tl1 Part 5

Function

Message Format

2 E3 Commands and Messages

72 / 166 3EC 36876 AEAA TCZZA Edition 02

2.2.2 REPT EVT E3

Reports current E3 facility events from the NE.

almcode atag REPT EVT E3 “aid_e3:cond_e3,[condeff],[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;

Response Parameters

Parameter Explanation

almcde Alarm code. Identifies the severity of the alarm. Values are:

A^ Non�alarm message

atag Automatic tag that indicates the numerical sequence of messages reported

aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this

is not required. Valid values are:

NTE3 (E3 Facility on the NT sides A and B)

NTE3A (E3 Facility on the NT side A)

NTE3B (E3 Facility on the NT side B)

LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)

rack Rack number (1...6)

shelf Shelf number (1...2)

lt_slot LT slot number (1...16)

circuit Circuit number (1...1)

cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3

[condeff] Effect of event on condition reported. Values are:

SC Standing condition raised

CL Standing condition cleared

TC Transient condition

Page 73: Asam Tl1 Part 5

2 E3 Commands and Messages

73 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

[ocrdat] Date of occurrence in the following format:

mm�dd Month and day

mm Month (1...12)

dd Day (1...31)

[ocrtm] Time of occurrence in the following format:

hh�mm�ss Hour, minute, and second

hh Hour (00...23)

mm Minute (00...59)

ss Second (00...59)

[locn] Location of condition. Values are:

NEND Near end

FEND Far end

[dirn] Direction of condition. Values are:

RCV Receive

TRMT Transmit

[cond_descr] Description of the alarm condition (1...40 characters)

Page 74: Asam Tl1 Part 5

2 E3 Commands and Messages

74 / 166 3EC 36876 AEAA TCZZA Edition 02

2.3 E3 Conditions

Table 3 lists the E3 conditions. In this table, [L] indicates conditions

that support the 'Location' parameter and [D] indicates conditions

that support the 'Direction' parameter

Table 3 E3 Conditions

Condition SERVEFF DEF NTFCNCDE Description

RAI SA Major Remote Alarm Indication.[L] [D]

AIS SA Critical Alarm Indication Signal.[L] [D]

LOF SA Critical Loss of framing.[L] [D]

LOS SA Critical Loss of Signal/Clock.[L] [D]

LCD* SA Critical Loss of ATM Cell Delineation.[L] [D]

ACTLPBK SA Critical Network Side in Loopback[L] [D]

PLM�P SA Minor Payload Type Mismatch[L] [D]

PLU SA Minor Stable Payload Type[L] [D]

UNEQ�P SA Minor Payload Unequipped[L] [D]

CELLSIG SA Critical False start�of�cell input signal [L][D]

OVRFLO SA Critical Buffer (FIFO) overflow [L][D]

UDRFLO SA Critical Buffer (FIFO) underflow [L] [D]

* These ATM Conditions are reported via the E3 facility.

Page 75: Asam Tl1 Part 5

2 E3 Commands and Messages

75 / 1663EC 36876 AEAA TCZZA Edition 02

2.4 E3 Monotypes

Table 4 lists the E3 Monotypes. In this table, the following

notations are used:

� NE = Near�end of the facility

� FE = Far�end of the facility

� RX = Receive.

Table 4 E3 Monotypes

Monotype Location Direction Description

CV�L NE RX Line Code Violations

ES�L NE RX Line Errored Seconds

ESP�P NE RX P-Bit Errored Seconds

SESP�P NE RX P-Bit Severely Errored Seconds

UASP�P NE RX P-Bit Un-Available Seconds

ESCP�P NE + FE RX CP-Bit Errored Seconds

SESCP�P NE + FE RX CP-Bit Severely Errored Seconds

UASCP�P FE RX CP-Bit Un-Available Seconds

SAS�P NE RX Severely Errored Framing Seconds

DHECV* NE RX Discarded Cells Due to HEC Violation

* These ATM monotypes are reported via the E3 facility.

Page 76: Asam Tl1 Part 5

2 E3 Commands and Messages

76 / 166 3EC 36876 AEAA TCZZA Edition 02

Page 77: Asam Tl1 Part 5

3 Environmental Commands and Messages

77 / 1663EC 36876 AEAA TCZZA Edition 02

3 Environmental Commands and Messages

This chapter provides information about the Environmental (ENV)

commands and messages. The chapter has the following main

parts:

� ENV Commands

� ENV Autonomous Messages.

� ENV Conditions.

Page 78: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

3 Environmental Commands and Messages

78 / 166 3EC 36876 AEAA TCZZA Edition 02

3.1 ENV Commands

This section describes the ENV commands.

3.1.1 RTRV�ALM�ENV

Retrieves current environment alarms.

All parameters in this command are position�defined.

RTRV-ALM-ENV:[tid]:aid_env:[ctag]::[ntfcde],;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_env Access identifier for the environment. Enter in the following format, replacing

lower�case parameters with the values given:

ENV�<number>

<number> 1...5

Grouping and ranging are allowed. ALL may be used.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[ntfncde] Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

Grouping and ranging are allowed. If no value is specified, ALL is assumed.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ALM-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ “aid_env:ntfncde,cond_env”;

Page 79: Asam Tl1 Part 5

Example

Related Commands

3 Environmental Commands and Messages

79 / 1663EC 36876 AEAA TCZZA Edition 02

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ALM-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_env As described for command parameters, except that ALL is not used

ntfncde As described for command parameters, except that ALL is not used

cond_env Environment�related alarm condition. Values are as defined in �ENV Conditions",

Section 3.3

Retrieve ADSL alarms for environment 4.

RTRV-ALM-ENV:RALGH:ENV-4:42:::,,;

RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-ALM-ADSL:RALGH:ENV-4:42:::,, */ “ENV:CR,MISC,SA”;

None

Page 80: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

3 Environmental Commands and Messages

80 / 166 3EC 36876 AEAA TCZZA Edition 02

3.1.2 RTRV�ATTR�ENV

Retrieves current attributes of environment�related conditions.

All parameters in this command are position�defined.

RTRV-ATTR-ENV:[tid]:aid_env:[ctag]::[ntfcde];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_env Access identifier for the environment. Enter in the following format, replacing

lower�case parameters with the values given:

ENV�<number>

<number> 1...5

Grouping and ranging are allowed. ALL may be used.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

[ntfncde] Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NR Not reported (information is stored in the NE)

Grouping is allowed. If no value is specified, ALL is assumed.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ATTR-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ “aid_env,aid_type:ntfncde,cond_env”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ATTR-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ errcde;

Page 81: Asam Tl1 Part 5

Example

Related Commands

3 Environmental Commands and Messages

81 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_env As described for command parameters, except that ALL is not used.

aid_type The type of Access Identifier. The value is ENV.

ntfncde Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NA Not alarmed (reported via REPORT EVENT)

NR Not reported (information is stored in the NE)

cond_env Environment�related alarm condition. Values are as defined in �ENV Conditions",

Section 3.3

Retrieve critical attributes for environment 4.

RTRV-ATTR-ENV:RALGH:ENV-4:42::CR;

RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-ATTR-ENV:RALGH:ENV-4:42::CR */ “ENV-4,ENV:CR,MISC”;

SET�ATTR�ENV

Page 82: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

3 Environmental Commands and Messages

82 / 166 3EC 36876 AEAA TCZZA Edition 02

3.1.3 RTRV�COND�ENV

Retrieves current conditions associated with an environmental

alarm input.

All parameters in this command are position�defined.

RTRV-COND-ENV:[tid]:aid_env:[ctag]::[cond_env];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

aid_env Access identifier for an environment. The value can be preceded with AID=, but

this is not required. Enter in the following formats, replacing lower�case

parameters with the values given:

ENV�<number>

<number> 1...5

Grouping and ranging are allowed. ALL may be used.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

cond_env Environment�related alarm condition. Values are as defined in �ENV Conditions",

Section 3.3

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-COND-ENV:[tid]:aid_env:[ctag]::[cond_env] */ “aid_env[,aid_type]:ntfncde,cond_env,,,,,,,[cond_descr]”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-COND-ENV:[tid]:aid_env:[ctag]::[cond_env] */ errcde;

Page 83: Asam Tl1 Part 5

Example

Related Commands

3 Environmental Commands and Messages

83 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (two digits), month, and day

hh:mm:ss Hour (00�23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

aid_env As described for command parameters, except that ALL is not used

[aid_type] Type of Access Identifier. The value is ENV.

[ntfncde] Notification code. Values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NR Not reported (information is stored in the NE)

cond_env As described for command parameters, except that ALL is not used

[cond_descr] Description of alarm condition (1...40 characters)

Retrieve current condition of environment number 4.

RTRV-COND-ENV:RALGH:ENV-4:42::;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-COND-ENV:RALGH:ENV-4:42:: */ “ENV-4:MN,MISC,NSA,,,,,,Miscellaneous Environment Alarm”;

None

Page 84: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

3 Environmental Commands and Messages

84 / 166 3EC 36876 AEAA TCZZA Edition 02

3.1.4 SET�ATTR�ENV

Sets the attributes of environment alarm conditions.

All parameters in this command are position�defined.

SET-ATTR-ENV:[tid]:aid_env:[ctag]::ntfncde;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NE's SID code is the only other valid value.

aid_env Access identifier for the environment. Enter in the following format, replacing

lower�case parameters with the values given:

ENV�<number>

<number> 1...5

Grouping and ranging are allowed. ALL may be used.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

ntfncde Notification code. Valid values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

NR Not reported (information is stored in the NE)

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-ATTR-ENV:[tid]:aid_env:[ctag]::ntfncde */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* SET-ATTR-ENV:[tid]:aid_env:[ctag]::ntfncde */ errcde;

Page 85: Asam Tl1 Part 5

Example

Related Command

3 Environmental Commands and Messages

85 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Associate the critical (CR) notification code with alarm conditions

on environment 4.

SET-ATTR-ENV:RALGH:ENV-4:42::CR;

RALGH 98-11-24 12:30:43M 42 COMPLD /* SET-ATTR-ENV:RALGH:ENV-4:42::CR */;

RTRV�ATTR�ENV

Page 86: Asam Tl1 Part 5

Function

Message Format

3 Environmental Commands and Messages

86 / 166 3EC 36876 AEAA TCZZA Edition 02

3.2 ENV Autonomous Messages

This section describes the ENV autonmous messages.

3.2.1 REPT ALM ENV

Reports current environment alarms from the NE.

almcode atag REPT ALM ENV “aid_env:ntfncde,cond_env,ocrdat,ocrtm,[conddescr]”;

Response Parameters

Parameter Explanation

almcde Alarm code. Identifies the severity of the alarm. Values are:

*C Critical alarm

** Major alarm

*^ Minor alarm

A^ Automatic message (typically used to report a cleared

alarm)

atag Automatic tag that indicates the numerical sequence of messages reported

aid_env Access identifier for the environment in the following format:

ENV�<number>

<number> 1...5

ntfncde Notification code. Values are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

CL Cleared alarm

Page 87: Asam Tl1 Part 5

3 Environmental Commands and Messages

87 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

cond_env Environment condition. The value is:

MISC Miscellaneous environment alarm

ocrdat Date of occurrence in the following format:

mm�dd Month and day

mm Month (1...12)

dd Day (1...31)

ocrtm Time of occurrence in the following format:

hh�mm�ss Hour, minute, and second

hh Hour (00...23)

mm Minute (00...59)

ss Second (00...59)

[conddescr] Text string of up to 40 characters that describes the alarm condition

Page 88: Asam Tl1 Part 5

3 Environmental Commands and Messages

88 / 166 3EC 36876 AEAA TCZZA Edition 02

3.3 Environmental (ENV) Conditions

Table 5 lists the ENV conditions.

Table 5 ENV Conditions

Condition SERVEFF DEF NTFCNCDE Description

MISC ** NSA NR Miscellaneous Environment Alarm

Note: There are 5 miscellaneous alarms corresponding to AIDs (ENV�1..5).

Page 89: Asam Tl1 Part 5

4 Miscellaneous System Commands

89 / 1663EC 36876 AEAA TCZZA Edition 02

4 Miscellaneous System Commands

This chapter provides information about the Miscellaneous System

commands.

Page 90: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

90 / 166 3EC 36876 AEAA TCZZA Edition 02

4.1 DLT�MEM

Deletes a software package from the NE.

In this release, only one action is supported: deletion of the

backup version of the NE provisioning database that is created

after a successful software migration. This is the database used by

the RST�MEM command. Once the database is deleted, the restore

operation becomes impossible.

All parameters in this command are position�defined.

DLT-MEM:[tid]:aid_com:[ctag]::swpkg;

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID

code is the only other valid value.

aid_com Access Identifier for common equipment. The value is COM.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

swpkg Software package to be deleted. The value is BACKUPDB (backup version of the

provisioning database.

Page 91: Asam Tl1 Part 5

Response Format

Example

Related Command

4 Miscellaneous System Commands

91 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* DLT-MEM:[tid]:aid_com:[ctag]::swpkg */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* DLT-MEM:[tid]:aid_com:[ctag]::swpkg */ errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

Delete the backup version of the provisioning database.

DLT-MEM:RALGH:COM:42::BACKUPDB;

RALGH 00-11-24 12:30:43M 42 COMPLD /* DLT-MEM:RALGH:COM:42::BACKUPDB */;

RST�MEM

Page 92: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

92 / 166 3EC 36876 AEAA TCZZA Edition 02

4.2 ED�SYNCN

Configures the reference source for synchronization of the NE

clocks.

All parameters in this command are position�defined.

ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

aid_syncn AID of the NE clock. The value is CLKSRCNT (default).

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

syncn_nblk Named parameter block for SYNCN. The block consists of the following

parameter, followed by an equal sign and a valid value.

PRICREF Primary reference source for synchronizing the clock.

Valid values are:

LOOP (Loop timing recovered from network side facili�

ty)

LOCAL (Local oscillator on NT board)

REDNT (Local oscillator on redundant NT board)

If not specified, the value of this parameter remains unchanged.

Page 93: Asam Tl1 Part 5

Response Format

Example

Related Commands

4 Miscellaneous System Commands

93 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (two digits), month, and day

hh:mm:ss Hour (00�23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

Configure the NE clock to use the BITS clock as its primary

reference source.

ED-SYNCN:RALGH:CLKSRCNT:42:::PRICREF=LOCAL;

RALGH 99-11-24 12:30:43M 42 COMPLD /* ED-SYNCN:RALGH:CLKSRCNT:42:::PRICREF=LOCAL */;

DLT�SYNCN

ENT�SYNCN

Page 94: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

94 / 166 3EC 36876 AEAA TCZZA Edition 02

4.3 FREE�PORT

Frees a port previously assigned to a user (by ED�ADSL,

ED�SHDSL, ED�E1, or RESV-NEXT�PORT).

Note User ports can be assigned to a user/customer, or be

free (available) for assignment. Assignment is based on

the value of the PORTID parameter associated with the

PORT. A specific port may be assigned using the

ED�(ADSL/SHDSL) commands, or any free (available)

port may be requested using the RESC�NEXT�PORT

command. Assigned ports may be freed (un�assigned)

using the FREE�PORT command.

Port assignment is independent of the state (faulty or otherwise)

and presence of connections on the port. You must verify the

condition of the port before freeing it.

All parameters in this command are position�defined.

FREE-PORT:[tid]:port_aid:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

port_aid Access identifier for the port. Enter in one of the following formats, replacing

lower�case parameters with the values given:

ADSL�rack�shelf�lt_slot�circuit

LTSHDSL�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4 for ADSL, 1...3 for SHDSL)

lt_slot LT slot number (1...16)

circuit Circuit number in LT (1...24)

Page 95: Asam Tl1 Part 5

Response Format

Example

Related Commands

4 Miscellaneous System Commands

95 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* FREE-PORT:[tid]:port_aid:[ctag][:] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* FREE-PORT:[tid]:port_aid:[ctag][:] */ aid:ERRCDE=errcde /* error description */;

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (1...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Free port ADSL�1�3�8�2.

FREE-PORT:RALGH:ADSL-1-3-8-2:40;

RALGH 00-01-24 12:30:43M 40 COMPLD /* FREE-PORT:RALGH:ADSL-1-3-8-2:40 */;

ED�ADSL

ED�T1

RESV�NEXT�PORT

Page 96: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

96 / 166 3EC 36876 AEAA TCZZA Edition 02

4.4 INIT�LOG

Initializes selected system log(s).

All parameters in this command are position�defined.

INIT-LOG:[tid]::[ctag]::lognms;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

lognms Names of logs to be initialized. The only supported value is SECURITY.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* INIT-LOG:[tid]::[ctag]::lognms */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* INIT-LOG:[tid]::[ctag]::lognms */ errcde;

Page 97: Asam Tl1 Part 5

Example

Related Command

4 Miscellaneous System Commands

97 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Initialize the SECURITY log.

INIT-LOG:RALGH::40::SECURITY;

RALGH 98-11-24 12:30:43M 40 COMPLD /* INIT-LOG:RALGH::40::SECURITY */;

RTRV�LOG

Page 98: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

98 / 166 3EC 36876 AEAA TCZZA Edition 02

4.5 INIT�SYS

Initializes or resets selected subsystems in the NE.

All parameters in this command are position�defined.

To restore persistent database, do the following:

a) Use STA�CMDSSN to start a command session.

b) Enable download by using SET�NE�ALL with

MEMDNLD=ENABLED.

c) Use TFTP to download the database file.

d) Restart the system by using INIT�SYS with INIT_MODE=4.

e) Use STP�CMDSSN to stop the command session.

INIT-SYS:[tid]:aid_proc:[ctag]::init_mode;

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID

code is the only other valid value.

aid_proc Identifier of the processor to be initialized. Grouping and ranging are not

allowed. Valid values are:

NTA Network Termination Unit�A

NTB Network Termination Unit�B

LT�rack�shelf�lt_slot Processor in LT unit

SERV�rack�shelf�serv_slot Processor in Server

where

SYSTEM Entire system

rack Rack number (1...6)

shelf Shelf number (1...4)

lt_slot LT slot number (1...16)

Serv_slot Server slot number (1...16)

No grouping or ranging is allowed

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Page 99: Asam Tl1 Part 5

Response Format

4 Miscellaneous System Commands

99 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

init_mode Mode of initialization. Valid values are:

0 Emergency restart for active NT only*

1 Initialize with self�test

2 Initialize without self�test

3 Complete reset (aid_proc=SYSTEM only). Removes all

persistent data from system.

4 Restart using downloaded persistent database

(aid_proc=SYSTEM only) (see Restrictions)

ATTENTION* = To be used only if a normal restart using the values 1 to

4 is not successful.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* INIT-SYS:[tid]:aid_proc:[ctag]::init_mode */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* INIT-SYS:[tid]:aid_proc:[ctag]::init_mode */ aid:ERRCDE=errcde /* error description */;

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

Page 100: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

100 / 166 3EC 36876 AEAA TCZZA Edition 02

Perform a complete reset of the NTA unit.

INIT-SYS:RALGH:NTA:40::3;

RALGH 00-11-24 12:30:43M 40 COMPLD /* INIT-SYS:RALGH:NTA:40::3 */;

None

Page 101: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

101 / 1663EC 36876 AEAA TCZZA Edition 02

4.6 RD�SYNCN

Retrieves the current reference source for synchronization of the

NE clock.

All parameters in this command are position�defined.

RD-SYNCN:[tid]:[aid_syncn]:[ctag][:];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

aid_syncn AID of the NE clock. The value is CLKSRCNT.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RD-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ aid_syncn,cref;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RD-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ errcde;

Page 102: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

102 / 166 3EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (two digits), month, and day

hh:mm:ss Hour (00�23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

aid_syncn As described for command parameters

cref Primary reference source for synchronizing the clock. Values are:

PRI�LOOP Loop timing recovered from network side facility

PRI�LOCAL Local oscillator on NT board

PRI�REDNT Local oscillator on redundant NT board

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

Retrieve the NE clock source.

RD-SYNCN:RALGH:CLKSRCNT:42;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RD-SYNCN:RALGH:CLKSRCNT:42 */

CLKSRCNT,PRI-LOCAL;

ED�SYNCN

RTRV�SYNCN

Page 103: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

103 / 1663EC 36876 AEAA TCZZA Edition 02

4.7 REPT�OPSTAT�ICON

Reports current operational parameters of the IQ�bus Controller

(ICON) subsystem of the ASAM.

All parameters in this command are position�defined.

REPT-OPSTAT-ICON:[tid]:[aid_com]:[ctag][:];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

[aid_com] Access Identifier for common equipment. The value is COM.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* REPT-OPSTAT-ICON:[tid]:[aid_com]:[ctag][:] */ “aid_com:op_icon,value”;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* REPT-OPSTAT-ICON:[tid]:[aid_icon]:[ctag][:] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00�23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

Page 104: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

104 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

aid_icon As described for command parameters

op_icon ICON subsystem operational parameter. Values are:

R<r>S<s> Status bitmap for shelf <s> in Rack <r>: n (1...8) in

each rack.

<r> Rack Number (1...6)

<s> Shelf (1...4)

If shelf n is not present in a rack, the value is a space

character. Otherwise, the value is a bitmap consisting

of three bits as follows:

Bit 0: LT equipped (1=yes, 0=no)

Bit 1: LT enabled (1=yes, 0=no)

Bit 2: LT powered down (1=yes, 0=no)

ORDER Sequence of shelves in the extender chain. The value is

a series of 8�digit hexadecimal numbers, in extender

chain order. The 5 least significant bits of each

number represent the settings of the backplane straps

for the corresponding shelf.

value Value of the parameter specified in op_icon

Report ICON subsystem operational parameters.

REPT-OPSTAT-ICON:RALGH:;

RALGH 99-11-24 12:30:43M 42 COMPLD /* REPT-OPSTAT-ICON:RALGH::42 */ “COM:SHELF1,\”300000000000 \“” “COM:SHELF2,\” \“” “COM:SHELF3,\” \“” “COM:SHELF4,\” \“” “COM:SHELF5,\” \“” “COM:SHELF6,\” \“” “COM:SHELF7,\” \“” “COM:SHELF8,\” \“” “COM:ORDER,\” : 00 \””;

None.

Page 105: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

105 / 1663EC 36876 AEAA TCZZA Edition 02

4.8 REPT�OPSTAT�NE

Reports current operational parameters for the system.

All parameters in this command are position�defined.

REPT-OPSTAT-NE:[tid]:[aid_com]:[ctag][:];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID

code is the only other valid value.

[aid_com] Access Identifier for common equipment. The value is COM.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Normal Response

tid yy-mm-dd hh:mm:ssM c COMPLD /* REPT-OPSTAT-NE:[tid]:[aid_com]:[ctag][:] */ “aid_com:op_ne,value” “aid_com:op_ne,value” . . .;

Error Response

tid yy-mm-dd hh:mm:ssM c DENY /* REPT-OPSTAT-NE:[tid]:[aid_com]:[ctag][:] */ aid:ERRCDE=errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (2 digits), month, and day

hh:mm:ss Hour (00...23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

Page 106: Asam Tl1 Part 5

4 Miscellaneous System Commands

106 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

aid_com As described for command parameters

op_ne,value Name and value (separated by a comma) of a system operational parameter.

Parameters are:

ACTCHN Currently active chain (side). Values are:

CHAINA (Chain A active)

CHAINB (Chain B active)

EQPTPRAC Equipment practice for this NE. Values are:

LAUS (Large�shelf US model)

MAUS (Mini�RAM US model)

LAEU (Large�shelf European model)

MAEU (Mini�RAM European model)

OTHER (Unknown equipment practice)

EXTCHALEN Length of extender chain, side A (integer 1...N)

EXTCHBLEN Length of extender chain, side B (integer 1...N)

FACASTATUS Status of NT facility side A. Values are:

NORMAL (Available)

LOS (Loss of signal)

LOF (Loss of framing)

AIS (Alarm indication signal)

BER (Excessive bit errors)

FACBSTATUS Status of NT facility side B. Values are the same as for

FACASTATUS.

MEMASTATUS Status of system memory, side A. Values are:

NORMAL (Memory is OK)

FAULT (Memory is not OK)

MEMBSTATUS Status of system memory, side B. Values are the same

as for MEMASTATUS.

MEMMIGR Memory migration status (see DLT�MEM and

RST�MEM). Values are:

IDLE (Migration not possible)

BUSY (Migration in progress)

COMPLETE (Migration completed, rollback possible)

Page 107: Asam Tl1 Part 5

4 Miscellaneous System Commands

107 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

op_ne,value (cont) MEMSYNC Memory synchronization between sides A and B.

Values are:

INSYNC (Both sides synchronized)

OUTSYNC (Both sides not synchronized)

BUSY (Synchronization in progress)

NTASTATUS Status of NT side A. Values are:

NORMAL (Available)

UNAVAIL (Not present)

UNREACH (Cannot communicate with unit)

NTBSTATUS Status of NT side B. Values are the same as for

NTASTATUS.

NUMPROTNSW Rolling count of protection switching events

PROTCURR Current protection switching mode. Values are:

INH (Administratively inhibited)

ALW (Allowed)

SWA (Manually switched to side A)

SWB (Manually switched to side B)

SWCAUSE Reason for last protection switch. Values are:

NOSW (No switch has occurred)

MANSW (Manual/administrative switch)

EQPTF (Equipment failure or removal switch)

EXTCHF (Extender chain failure switch)

LNKF (Link (NT facility) failure switch)

TMOUT (watchdog timer timed out switch)

MEMf (database corruption caused switch)

MISMATCH (mismatch of board type or SW variant)

Page 108: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

108 / 166 3EC 36876 AEAA TCZZA Edition 02

Report system operational parameters.

REPT-OPSTAT-NE:RALGH:COM:42;

RALGH 00-11-24 12:30:43M 42 COMPLD /* REPT-OPSTAT-NE:RALGH:COM:42 */ “COM:ACTCHN,CHAINA” “COM:EQPTPRAC,LAUS “COM:EXTCHALEN,1” “COM:EXTCHBLEN,2” “COM:FACASTATUS,NORMAL” “COM:FACBSTATUS,NORMAL “COM:MEMASTATUS,NORMAL “COM:MEMBSTATUS,NORMAL” “COM:MEMMIGR,COMPLETE “COM:MEMSYNC,INSYNC” “COM:NTASTATUS,NORMAL” “COM:NTBSTATUS,NORMAL “COM:NUMPROTNSW,0” “COM:PROTCURR,ALW” “COM:SWCAUSE,NOSW”

DLT�MEM

RST�MEM

Page 109: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

109 / 1663EC 36876 AEAA TCZZA Edition 02

4.9 RESV�NEXT�PORT

Reserves the first available port of a particular type for a user. If a

free port is found, it is assigned; otherwise, an error is reported.

Note User ports can be assigned to a user/customer, or be

free (available) for assignment. Assignment is based on

the value of the PORTID parameter associated with the

PORT. A specific port may be assigned using the

ED�(ADSL/SHDSL) commands, or any free (available)

port may be requested using the RESC�NEXT�PORT

command. Assigned ports may be freed (un�assigned)

using the FREE�PORT command.

All parameters in this command are position-defined. Port

assignment is independent of the state (faulty or otherwise) and

presence of connections on the port. You must verify the condition

of the port before reserving it.

RESV-NEXT-PORT:[tid]:port_type:[ctag]::port_id;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

port_type Type of port to be assigned. Valid values are:

ADSL ADSL port

SHDSL SHDSL port

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

port_id Label used to mark the port as assigned to a particular user (1...32 characters).

The following values are reserved and cannot be used:

AVAILABLE Port is not assigned

FAULTY Port is faulty and cannot be assigned

Page 110: Asam Tl1 Part 5

Response Format

4 Miscellaneous System Commands

110 / 166 3EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RESV-NEXT-PORT:[tid]:port-type:[ctag]::port_id */ port_type:port_aid;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RESV-NEXT-PORT:[tid]:port-type:[ctag]::port_id */ aid:ERRCDE=errcde /* error description */;

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (1...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

port_type As described for command parameters

port_aid Access identifier for the port. Values are:

ADSL�rack�shelf�lt_slot�circuit

LTSHDSL�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4, for ADSL, 1...3 for SHDSL)

lt_slot LT slot number (1...16)

circuit Circuit number (1...24)

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Page 111: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

111 / 1663EC 36876 AEAA TCZZA Edition 02

Free port ADSL�1�3�8�2.

RESV-NEXT-PORT:RALGH:ADSL:40::ARTURO;

RALGH 00-01-24 12:30:43M 40 COMPLD /* RESV-NEXT-PORT:RALGH:ADSL:40::ARTURO */ ADSL:ADSL-1-3-8-2;

ED�ADSL

ED�T1

FREE�PORT

Page 112: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

112 / 166 3EC 36876 AEAA TCZZA Edition 02

4.10 RST�MEM

Restores the NE provisioning database to the backup version, if

one exists.

Note A backup database is saved during NE software

migration. It can be deleted with DLT�MEM.

All parameters in this command are position�defined.

RST–MEM:[tid]:aid_com:[ctag][:];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID

code is the only other valid value.

aid_com Access Identifier for all common equipment. The value is COM.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Normal Response

tid yy-mm-dd hh:mm:ssM c COMPLD /* RST–MEM:[tid]:aid_com:[ctag][:] */;

Error Response

tid yy-mm-dd hh:mm:ssM c DENY /* RST–MEM:[tid]:aid_com:[ctag][:] */ aid:ERRCDE=errcde /* error description */;

Page 113: Asam Tl1 Part 5

Example

Related Command

4 Miscellaneous System Commands

113 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (2 digits), month, and day

hh:mm:ss Hour (00...23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

aid_com As described for command parameters

Restore the NE provisioning database to the backup version

created during the last NE software migration.

RST-MEM:RALGH:COM:42;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RST-MEM:RALGH:COM:42 */

DLT�MEM

Page 114: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

114 / 166 3EC 36876 AEAA TCZZA Edition 02

4.11 RTRV�CMDSSN

Retrieves information about active Command Sessions.

All parameters in this command are position�defined.

At this moment only two Command Session owners are

supported:

� 5523 AWS: ADSL workstation (or another SNMP manager)

� Craft: craft interface.

Note: The CRAFT session is shared by all TL1 managers

including Local & Remote Craft Interfaces, as well as the TL1

Operations System.

Only one manager at a time can have a Command Session open.

The Craft Interface can have multiple nested Command sessions.

Command Sessions left idle for more than one minute are

automatically terminated. In case of a Craft Session, activity by

any TL1 manager keeps all Craft sessions active.

RTRV-CMDSSN:[tid]:aid_com:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_com Access identifier for all common equipment. The value is COM.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-CMDSSN:[tid]:aid_com:[ctag][:] */ aid_com:cmdssn_owner;

Page 115: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

115 / 1663EC 36876 AEAA TCZZA Edition 02

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-CMDSSN:[tid]:aid_com:[ctag][:] */ errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (1...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_com As described for command syntax

cmdssn_owner Owner of the Command Session. Valid values are:

AWS ADSL workstation (or another SNMP Manager)

CRAFT TL1 Manager (Local Craft, Remote Craft, or TL1 OS)

Retrieve information about active Command Sessions.

RTRV-CMDSSN:RALGH:COM:42;

RALGH 99-01-24 12:30:43M 42 COMPLD /* RTRV-CMDSSN:RALGH:COM:42 */ COM:AWS COM:CRAFT;

RTRV�CMDSSN

STA�CMDSSN

STP�CMDSSN

Page 116: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

116 / 166 3EC 36876 AEAA TCZZA Edition 02

4.12 RTRV�HDR

Retrieves the NE header information.

All parameters in this command are position�defined.

RTRV-HDR:[tid]::[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-HDR:[tid]::[ctag][:] */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-HDR:[tid]::[ctag][:] */ errcde;

Page 117: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

117 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Retrieve header information for the RALGH NE.

RTRV-HDR:RALGH::42;

RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-HDR:RALGH::42 */;

None.

Page 118: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

118 / 166 3EC 36876 AEAA TCZZA Edition 02

4.13 RTRV�LOG

Retrieves selected logs.

All parameters in this command are position�defined.

RTRV-LOG:[tid]::[ctag]::lognms;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

lognms Names of logs to be retrieved. The only supported value is SECURITY.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-LOG:[tid]::[ctag]::lognms */ “lognms” /* logdump */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-LOG:[tid]::[ctag]::lognms */ errcde;

Page 119: Asam Tl1 Part 5

Example

Related Command

4 Miscellaneous System Commands

119 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

lognms As described for command parameters

logdump Dump of log buffer

Retrieve the SECURITY log.

RTRV-LOG:RALGH::40::SECURITY;

RALGH 98-11-24 12:30:43M 40 COMPLD /* RTRV-LOG:RALGH::40::SECURITY */ (dump of log buffer);

INIT�LOG

Page 120: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

120 / 166 3EC 36876 AEAA TCZZA Edition 02

4.14 RTRV�MEM

Retrieves the list of software image files available in the NE, along

with the software version associated with each file.

All parameters in this command are position�defined.

RTRV-MEM:[tid]:aid_com:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_com Access Identifier for all common equipment. The value is COM.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-MEM:[tid]:aid_com:[ctag][:] */ filename[,filename,...];

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-MEM:[tid]:aid_com:[ctag][:] */ errcde;

Page 121: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

121 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

filename Name of a software module

Retrieve the list of software image files for the RALGH NE.

RTRV-MEM:RALGH:COM:40;

RALGH 98-11-24 12:30:43M 40 COMPLD /* RTRV-MEM:RALGH:COM:40 */ (filename);

None

Page 122: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

122 / 166 3EC 36876 AEAA TCZZA Edition 02

4.15 RTRV�NE�ALL

Retrieves common provisioning data associated with the NE.

All parameters in this command are position�defined.

RTRV-NE-ALL:[tid]:[aid_com]:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

[aid_com] Access Identifier for all common equipment. The value is COM.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-NE-ALL:[tid]:[aid_com]:[ctag][:] */ aid_com:ne_nblk;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-NE-ALL:[tid]:[aid_com]:[ctag][:] */ errcde;

Page 123: Asam Tl1 Part 5

4 Miscellaneous System Commands

123 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

aid_com As described for command parameters

ne_nblk NE named parameter block containing one or more of the following parameters

(separated by commas):

APSSOAKINT The soaking period for activation of Automatic

protection switching (APS) in 1/100 seconds

(0..4294967295). 0 implies no soaking period

BOOTPVCI ATM VCI of the PVC over which the NE issues BOOTP

requests (32...65535)

BOOTPVPI ATM VPI of the PVC over which the NE issues BOOTP

requests (0...4000). Default is 0.

CMDSSNTMO Timeout for an idle command session (see

STA�CMDSSN or STP�CMDSSN), in seconds

(0...65535). A value of 0 disables the timeout feature.

DEFROUTER IP address of default IP router (if a router is used to

connect the AWS). Values are:

ddd.ddd.ddd.ddd (IP address, where ddd = 0...255)

NONE (No default IP router is used)

AWS must be used to configure SNTP.

EPSSOAKINT The soaking period for activation of equipment

protection switching (EPS) in 1/100 seconds

(0..4294967295).. 0 implies no soaking period

MEMALM Status of alarm condition indicating loss or corruption

of persistent memory. Values are:

ACTIVE (Persistent memory lost or corrupted)

CLEAR (Persistent memory OK)

After a loss or corruption of persistent memory is cor�

rected, the alarm condition must be manually cleared

using the MEMALM=CLEAR parameter of the SET�NE�

ALL command.

Page 124: Asam Tl1 Part 5

4 Miscellaneous System Commands

124 / 166 3EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

ne_nblk (cont) MEMDNLD Whether external download of system persistent

database is enabled. External download is typically

used to restore the database from a previous backup

version (see INIT�SYS). Values are:

ENABLED (Download is allowed)

DISABLED (Download is not allowed)

MEMSYNC Persistent memory synchronization in protection mode.

Values are:

DISABLED�(Memory synchronization is disabled)

ENABLED�(Memory synchronization is enabled)

NETPOS Position of the NE in the access subnetwork. Valid

values are:

HUB (NE is directly connected to the network)

SUBTENDING (NE is subtending from another ASAM.

No VC�level connections are allowed for a subtending

NE.)

Note: This parameter is not used and is available only

for backward compatibility. It will be removed in a fu�

ture release.

POTSTSTDUR Duration of the ADSL facility POTS test in minutes

(0...60). See STA�TST�ADSL command.

SNTP Use of Simple Network Time Protocol to maintain NE

clock. Values are:

ENABLED (Use SNTP)

DISABLED (Use NE local time set by SET�DAT com�

mand)

TZOFFSET Offset of local time zone from GMT/UTC, in minutes

(�780...780). Used by the system if SMTP=ENABLED.

Page 125: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

125 / 1663EC 36876 AEAA TCZZA Edition 02

Retrieve the common provisioning data associated with the

RALGH NE.

RTRV-NE-ALL:RALGH:COM:40;

RALGH 00-11-24 12:30:43M 40 COMPLD /* RTRV-NE-ALL:RALGH:COM:40 */ COM:BOOTPVPI=0,BOOTPVCI=32;

INIT�SYS

SET�DAT

SET�NE�ALL

STA�CMDSSN

STP�CMDSSN

Page 126: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

126 / 166 3EC 36876 AEAA TCZZA Edition 02

4.16 RTRV�PORT

Retrieves a port in the NE, based on the optional Port Identifier

label associated with the port.

All parameters in this command are position�defined. If the Port

Identifier is not unique, the first port that matches the specified

value is returned.

RTRV-PORT:[tid]:[port_type]:[ctag]::port_id;

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

[port_type] Type of port to be retrieved. The only valid value is ALL.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

port_id Port Identifier label (1...32 characters) associated with the port to be retrieved.

The label is assigned with the RESV�NEXT�PORT command or the PORTID

parameter of the ED�ADSL and ED�SHDSL commands.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-PORT:[tid]:[port_type]:[ctag]::port_id */ port_type:port_aid;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY; /* RTRV-PORT:[tid]:[port_type]:[ctag]::port_id */ errcde;

Page 127: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

127 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (two digits), month, and day

hh:mm:ss Hour (00�23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

port_type Type of port. Values are:

ADSL ADSL port

SHDSL SHDSL port

port_aid AID of the user port. Values are:

ADSL�rack�shelf�slot�circuit

LTSHDSL�rack�shelf�lt_slot�circuit

rack Rack number (1...6)

shelf Shelf number (1...4 for ADSL; 1...3 for SHDSL)

lt_slot LT slot number (1...16)

circuit Circuit number (1...24)

Retrieve the first port associated with user HARRINGTON.

RTRV-PORT:RALGH:ALL:42::HARRINGTON;

RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-PORT:RALGH:ALL:42::HARRINGTON */ ADSL:ADSL-3-2-7-1;

ED�ADSL

ED�T1

RESV�NEXT�PORT

Page 128: Asam Tl1 Part 5

Function

Restrictions

Command Format

Response Format

4 Miscellaneous System Commands

128 / 166 3EC 36876 AEAA TCZZA Edition 02

4.17 RTRV�SYNCN

Retrieves the configuration of the reference source to be used for

synchronization of the NE clock.

All parameters in this command are position�defined.

RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:];

Command Parameters

Parameter Explanation

[tid] Identification of the target NE. TID is optional and has an Alcatel factory default

value of null. The NEs SID code is the only other valid value.

[aid_syncn] AID of the NE clock. The value is CLKSRCNT.

[ctag] Correlation tag (1...6 characters) that links an input command with associated

output responses. The default is 0.

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ aid_syncn::[syncn_nblk];

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ errcde;

Page 129: Asam Tl1 Part 5

Example

Related Commands

4 Miscellaneous System Commands

129 / 1663EC 36876 AEAA TCZZA Edition 02

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (two digits), month, and day

hh:mm:ss Hour (00�23), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (see Appendix B)

[aid_syncn] As described for command parameters

syncn_nblk Clock synchronization parameter block. The block consists of the following

parameter, followed by an equal sign and a value.

PRICREF Primary reference source for synchronizing the clock.

Values are:

LOOP (Loop timing recovered from network side facili�

ty)

LOCAL (Local oscillator on NT board)

REDNT (Local oscillator on redundant NT board)

Retrieve the configuration of the reference source for

synchronization of the NE clock.

RTRV-SYNCN:RALGH:CLKSRCNT:42;

RALGH 99-11-24 12:30:43M 42 COMPLD /* RTRV-SYNCN:RALGH:CLKSRCNT:42 */ CLKSRCNT::PRICREF=LOCAL;

DLT�SYNCN

ED�SYNCN

ENT�SYNCN

Page 130: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

130 / 166 3EC 36876 AEAA TCZZA Edition 02

4.18 SET�DAT

Sets the date and time in the NE.

All parameters in this command are position�defined.

Resetting the NT or the ASAM also resets the date and time.

SET-DAT:[tid]::[ctag]::date,time;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NE's SID code is the only other valid value.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

date Date in the following format:

mm�dd�yy Month, day, and year

mm Month (1...12)

dd Day (1...31)

yy Year (00...99)

Note: Following interpretation is used for yy:

00..69 --> 2000...2069

70..99 --> 1970...1999

Current implementation restricts dates between 1970

and 2035.

time Time in the following format:

hh�mm�ss Hour, minute, and second

hh Hour (00...23)

mm Minute (00...59)

ss Second (00...59)

Page 131: Asam Tl1 Part 5

Response Format

Example

Related Command

4 Miscellaneous System Commands

131 / 1663EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-DAT:[tid]::[ctag]::date,time */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* SET-DAT:[tid]::[ctag]::date,time */; errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Set the date to 20 December 2000 and the time to 11:23:45 in

the RALGH NE.

SET-DAT:RALGH::42::12-20-00,11-23-45;

RALGH 00-12-20 11:23:45M 42 COMPLD /* SET-DAT:RALGH::42::12-20-00,11-23-45 */;

None.

Page 132: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

132 / 166 3EC 36876 AEAA TCZZA Edition 02

4.19 SET�NE�ALL

Sets miscellaneous provisioning parameters in an NE.

All parameters in this command are position�defined.

SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NE's SID code is the only other valid value.

[aid_com] Access Identifier for all common equipment. The value is COM.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

ne_nblk NE named parameter block containing one or more of the following parameters

(separated by commas):

BOOTPVPI ATM VPI of the PVC over which the NE issues BOOTP

requests (0...4000). The default is 0.

BOOTPVCI ATM VCI of the PVC over which the NE issues BOOTP

requests (32...65535). The default is 32.

CMDSSNTMO Timeout for an idle command session (see

STA�CMDSSN or STP�CMDSSN), in seconds

(0...65535). A value of 0 disables the timeout feature.

DEFROUTER IP address of default IP router (if a router is used to

connect the AWS). Values are:

ddd.ddd.ddd.ddd (IP address, where ddd =

1...255)

NONE (No default IP router is used)

MEMALM Used to clear an alarm condition indicating loss or

corruption of persistent memory (see RTRV�NE�ALL).

Valid values are:

CLEAR (persistent memory OK)

ACTIVE (persistent memory lost/corrupted

Note: An active alarm must be cleared after restoring

memory.

MEMDNLD Whether external download of system persistent

database is enabled (see RTRV�NE�ALL). The only valid

value is ENABLED.

Page 133: Asam Tl1 Part 5

4 Miscellaneous System Commands

133 / 1663EC 36876 AEAA TCZZA Edition 02

Parameter Explanation

ne_nblk (cont) NETPOS Position of the NE in the access subnetwork. Valid

values are:

HUB (NE is directly connected to the network)

SUBTENDING (NE is subtending from another ASAM.

No VC�level connections are allowed for a subtending

NE.)

Note: This parameter is not used and is available only

for backward compatibility. It will be removed in a fu�

ture release.

POTSTSTDUR Duration of the ADSL facility POTS test in minutes

(0...60). See STA�TST�ADSL command.

SNTP Use of Simple Network Time Protocol to maintain NE

clock. Values are:

ENABLED (Use SNTP)

DISABLED (Do not use SNTP; use NE local time set by

SET�DAT command)

AWS must be used to configure SNTP.

TZOFFSET Offset of local time zone from GMT/UTC, in minutes

(�780...780). Used by the system if SMTP=ENABLED.

APSSOAKINT The soaking period for activation of Automatic

protection switching (APS) in 1/100 seconds

(0..4294967295). 0 implies no soaking period

EPSSOAKINT The soaking period for activation of equipment

protection switching (EPS) in 1/100 seconds

(0..4294967295). 0 implies no soaking period

MEMSYNC Persistent memory synchronization in protection mode.

Values are:

DISABLED�(Memory synchronization is disabled)

ENABLED�(Memory synchronization is enabled)

Only parameters specified in the Ne_nblk will be changed. Other parameters re�

main unchanged

Page 134: Asam Tl1 Part 5

Response Format

Example

Related Commands

4 Miscellaneous System Commands

134 / 166 3EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk */ errcde;

Response Parameters

Parameter Explanation

sid Source NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Set the common provisioning parameters for the RALGH NE.

SET-NE-ALL:RALGH:COM:40:::BOOTPVPI=4003,BOOTPVCI=29730;

RALGH 00-11-24 12:30:43M 40 COMPLD /* SET-NE-ALL:RALGH:COM:40:::BOOTPVPI=4003,BOOTPVCI=29730 */;

RTRV�NE�ALL

SET�DAT

STA�TST�ADSL

STP�TST�ADSL

Page 135: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

135 / 1663EC 36876 AEAA TCZZA Edition 02

4.20 SET�SID

Sets the system identifier (SID) of the NE. The SID is used to

uniquely identify an NE in the system, so the SID must be unique

for each NE.

All parameters in this command are position�defined.

The SID is used to uniquely identify an NE in the system, so the

SID must be unique for each NE.

SET-SID:[tid]::[ctag]::sid;

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NE's SID code is the only other valid value.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

sid System identifier (SID). A text string of up to 20 characters containing only letters,

digits or hyphens. It is recommended to use the NEs CCLI code as the SID.

Note: The SID is case�sensitive.

Page 136: Asam Tl1 Part 5

Response Format

Example

Related Commands

4 Miscellaneous System Commands

136 / 166 3EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-SID:[tid]::[ctag]::sid */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* SET-SID:[tid]::[ctag]::sid */; errcde;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (00...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

errcde Error code (See Appendix B)

Set the SID for the RALGH NE to �RALEIGH�NC".

SET-SID:RALGH::42::RALEIGH-NC;

RALGH 98-12-20 11:23:45M 42 COMPLD /* SET-SID:RALGH::42::RALEIGH-NC */;

None.

Page 137: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

137 / 1663EC 36876 AEAA TCZZA Edition 02

4.21 STA�CMDSSN

Initiates a Command Session on behalf of the issuing manager.

While a Command Session is in progress, only the owner of the

session can modify the NE database.

At this moment only two Command Session owners are

supported:

� 5523 AWS: ADSL workstation (or another SNMP manager)

� Craft: craft interface.

Note: The CRAFT session is shared by all TL1 managers

including Local & Remote Craft Interfaces, as well as the TL1

Operations System.

Only one Manager can have an active Command Session at one

time. The Craft Interface can have multiple nested Command

Sessions. Command Sessions left idle for more than one minute

are automatically terminated. Activity by any TL1 manager keeps

all Craft Command Sessions active.

STA-CMDSSN:[tid]:aid_com:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NEs SID code is the only other valid value.

aid_com Access identifier for all common equipment. The value is COM.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Page 138: Asam Tl1 Part 5

Response Format

Example

Related Commands

4 Miscellaneous System Commands

138 / 166 3EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* STA-CMDSSN:[tid]:aid_com:[ctag][:]; */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* STA-CMDSSN:[tid]:aid_com:[ctag][:]; */ aid_com:ERRCDE=errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (1...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

aid_com As described for command parameters

errcde Error code (See Appendix B)

Initiate a Command Session.

STA-CMDSSN:RALGH:COM:42;

RALGH 99-01-24 12:30:43M 42 COMPLD /* STA-CMDSSN:RALGH:COM:42 */;

RTRV�CMDSSN

STP�CMDSSN

Page 139: Asam Tl1 Part 5

Function

Restrictions

Command Format

4 Miscellaneous System Commands

139 / 1663EC 36876 AEAA TCZZA Edition 02

4.22 STP�CMDSSN

Terminates any active 'Command Session' owned by the issuing

manager.

All TL1 managers share ownership of their Command Sessions, so

care should be exercised when issuing this command.

At this moment only two Command Session owners are

supported:

� 5523 AWS: ADSL workstation (or another SNMP manager)

� Craft: craft interface.

Note: The CRAFT session is shared by all TL1 managers

including Local & Remote Craft Interfaces, as well as the TL1

Operations System.

Only one manager at a time can have an active Command

Session. The Craft Interface can have multiple nested Command

Sessions. Command Sessions left idle for more than one minute

are automatically terminated. Activity by any TL1 manager keeps

all Craft Command sessions alive.

STP-CMDSSN:[tid]:aid_com:[ctag][:];

Command Parameters

Parameter Explanation

[tid] The identification of the target NE. TID is optional and has an Alcatel factory

default value of null. The NE's SID code is the only other valid value.

aid_com Access identifier for all common equipment. The value is COM.

[ctag] The correlation tag that correlates an input command with its associated output

response(s). It is assigned by the originator of the command. The value is limited

to six characters, which may be an identifier or a decimal numeral. It is optional

with a default of 0.

Page 140: Asam Tl1 Part 5

Response Format

Example

Related Commands

4 Miscellaneous System Commands

140 / 166 3EC 36876 AEAA TCZZA Edition 02

Normal Response

sid yy-mm-dd hh:mm:ssM c COMPLD /* STP-CMDSSN:[tid]:aid_com:[ctag][:]; */;

Error Response

sid yy-mm-dd hh:mm:ssM c DENY /* STP-CMDSSN:[tid]:aid_com:[ctag][:]; */ aid_com:ERRCDE=errcde /* error description */;

Response Parameters

Parameter Explanation

tid Target NE identification

yy�mm�dd Year (last two digits), month, and day

hh:mm:ss Hour (1...24), minute, and second

M Message generated in response to an input command

c If provided, ctag; otherwise 0

COMPLD Completed

DENY Input command is denied

/* */ Enclosed are human readable comments � unspecified format

aid_com As described for command parameters

errcde Error code (See Appendix B)

Terminate any active Command Sessions.

STP-CMDSSN:RALGH:COM:42;

RALGH 99-01-24 12:30:43M 42 COMPLD /* STP-CMDSSN:RALGH:COM:42 */;

RTRV�CMDSSN

STA�CMDSSN

Page 141: Asam Tl1 Part 5

Default NotificationCode (NTFCNCDE)

Appendix A Alarms and Events

141 / 1663EC 36876 AEAA TCZZA Edition 02

Appendix A Alarms and Events

A.1 General Description

This appendix provides tables that summarize the provisionable

and non�provisionable characteristics of the condition types used

by the ASAM. Condition types help you to isolate the type of error

to minimize the time taken to clear delays. These tables should be

useful after initial provisioning. (Refer to the Task Oriented

Procedures manual for complete provisioning instructions.)

When errors are detected by the system, you are notified by either:

� Retrieving current alarm conditions using TL1 commands or

� Receiving automatically generated system status and event

reporting through autonomous messages.

A.2 Retrieving Current Status of Alarms and Conditions

Provisionable alarm conditions have associated notification codes

with varying degrees of severity. Although these alarms have

default notification codes, most codes can be changed using the

set attribute (SET�ATTR�<xxx>) TL1 commands, where <xxx>

represents the entity associated with the alarm condition. When

the notification codes are set, the current alarm conditions can be

retrieved at any time using the retrieve alarm (RTRV�ALM�<xxx>)

and retrieve condition (RTRV�COND�<xxx>) TL1 commands for

an entity. The standard alarm notification codes are:

CR Critical alarm

MJ Major alarm

MN Minor alarm

A.3 Table Description

The tables in this appendix are organized by entities that are valid

for the ASAM. Each condition type is listed with the default

notification code values, service�affecting/non�service�affecting

behavior codes, and brief descriptions.

In the following tables, the default notification code column lists

the default alarm notification codes for the equipment or facility.

Most notification codes can be changed by the SET�ATTR TL1

command for that entity.

Page 142: Asam Tl1 Part 5

Service�affecting/Non�service�affecting

Behaviour

Appendix A Alarms and Events

142 / 166 3EC 36876 AEAA TCZZA Edition 02

If the notification code is Critical, Major, or Minor, an alarm

autonomous message (REPT�ALM) reports changes in the alarm

condition for in service (IS) entities. If the entity is out�of�service

(OOS�MA), reporting is suppressed. The RTRV�ALM or

RTRV�COND commands are used to retrieve the current state of

the alarm.

Service�affecting behavior is listed as either service�affecting (SA)

or non�service�affecting (NSA).

ADSL Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁFACTERM

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMajor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁModem could not initializeÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LCD�I*

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of cell delineation, interleaved

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LCD�F* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of cell delineation, fast

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOF ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of frame

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOL ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of link

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of signal

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LPRÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of power

CFGERR SA Critical Modem activation failed�config error

COMMF SA Major Unable to communicate w/ peer modem

CAPINSUF SA Major Line capacity insufficient to meet config

NOPEER SA Minor No peer modem detected

LORATE SA Minor Line rate is below planned rate

CELLDSCUP* SA Minor Upstream cell discard

CELLDSCDN* SA Minor Downstream cell discard

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

*ATM alarms reported via the ADSL facility

Page 143: Asam Tl1 Part 5

Appendix A Alarms and Events

143 / 1663EC 36876 AEAA TCZZA Edition 02

Common Equipment / NE (COM) Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

INIT SA Critical System ans backup memory reset

IQCLKOOL SA Critical IQ-bus clock not locked to reference

IQREFCLK SA Critical IQ-bus reference clock lost

SNTPCOM NSA Major Unable to communicate w/ SNTP server

SWCAP NSA Major Loss of protection switching

DISKSPACE NSA Major Disk is 90% full

E1 Facility Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ACTLPBK ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁFacility placed in loopback

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

AIS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁAlarm indication signal

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

FAULT�IMA**ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IMA link fault

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LCD*ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of ATM cell delineationÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLIF**

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of IMA frameÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LODS**

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IMA link out of delay synchronization

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MISMATCH ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁInterface does ot match configuration

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOF ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMajor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of framing

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of signal/clock

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MISCONN** ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA link misconnected

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RAIÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Remote alarm indication

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RFI�IMA**ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IMA remote failure indicationÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

UNUSABLE�IMA**ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IMA link unusable due to far�end

behavior

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

*ATM condition reported via the T1 facility (for E1s directly transporting ATM)

**IMA condition reported via the T1 facility (for E1s used as a link with IMA)

Page 144: Asam Tl1 Part 5

Appendix A Alarms and Events

144 / 166 3EC 36876 AEAA TCZZA Edition 02

Environment (ENV) Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMISC*

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁNSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁMiscellaneous environment alarmÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

*There are five miscellaneous alarms, corresponding to AIDs ENV�1 through ENV�5.

Equipment Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ATMHW ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ATM hardware error

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

BUSCFG ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Critical ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Backplane configuration error

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

COMMERRÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MajorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Failed to communicate with the module

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

CONTBUSÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Subrack backplane faultÁÁÁÁÁÁÁÁÁÁÁÁÁÁCONTCOM

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁCritical

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSubrack extender bus faultÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁEQPT

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁEvent

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁEquipment insertedÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

FA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Fuse alarm (power fuse blown)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

FANALM�1 ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Fan alarm for Fan�1

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

FANALM�2 ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Fan alarm for Fan�2

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

HITEMP ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Module temperature exceeded limit

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IMPROPRMVL ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Improper removal of provisioned module

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

INITÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

System and backup memory resetÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IQCLKOOLÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IQ�Bus clock not locked to referenceÁÁÁÁÁÁÁÁÁÁÁÁÁÁIQREFCLK

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁCritical

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁIQ�Bus reference clock lostÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MEMDIF

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Plug�in module does not match

configurationÁÁÁÁÁÁÁÁÁÁÁÁÁÁPROGVER

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁNSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMajor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁFailed to load or find requested softwareÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RMTDLFAIL

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Major

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Failed to download software

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SHUTDOWN ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Equipment shutdown due to high

temperatureÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SWROLLBK

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Software version rolled back

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

UNPLANNED ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Module inserted in slot planned for

NO�BOARD

MEMDIFEH NSA Minor Equipment holder config mismatch

DEFENCE SA Critical Equipment shutdown�defense action

EQUIP - Event Module inserted

UNEQUIP - Event Module removed

Page 145: Asam Tl1 Part 5

Appendix A Alarms and Events

145 / 1663EC 36876 AEAA TCZZA Edition 02

IMA Group Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

BLOCKED ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁGroup operation inhibited

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

CFGABORT ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Remote configuration request not

supported

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

INSUFLNKS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Insufficient number of IMA links to

operate

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

STARTUP ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁRemote IMA group start�up

IMA Link Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLIF *

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of IMA Frame.ÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LODS *

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IMA Link out of Dealy Sunchronization

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MISCONN* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA Link misconnected

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RFI�IMA* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA Remote failure indication

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

FAULT�IMA* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA link fault

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

UNUSABLE�IMA*ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IMA Link unusable due to Far�end

behavior

*IMA Link related conditions are reported via the associated facilty

(e.g. E1/T1/SHDSL). However their attributes can only be

provisioned using the SET/RTRV�ATTR�IMALNK commands.

Page 146: Asam Tl1 Part 5

Appendix A Alarms and Events

146 / 166 3EC 36876 AEAA TCZZA Edition 02

SHDSL Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOSW-NS�1

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of sync word - Network Side �

Loop1ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOSW-NS�2ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of sync word - Network Side �

Loop2

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOSW-CS�1ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of sync word - Customer Side �

Loop1

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOSW-CS�2ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of sync word - Customer Side �

Loop2

ATEN�NS�1 SA Minor Loop attenuation alarm - Network Side �

Loop1

ATEN�NS�2 SA Minor Loop attenuation alarm - Network Side �

Loop2

ATEN�CS�1 SA Minor Loop attenuation alarm - Customer Side

� Loop1

ATEN�CS�2 SA Minor Loop attenuation alarm - Customer Side

� Loop2

SNR�NS�1 SA Minor Signal to noise ratio alarm - Network

Side � Loop1

SNR�NS�2 SA Minor Signal to noise ratio alarm - Network

Side � Loop2

SNR�CS�1 SA Minor Signal to noise ratio alarm - Customer

Side � Loop1

SNR�CS�2 SA Minor Signal to noise ratio alarm - Customer

Side � Loop2

DCCONT�NS�1 SA Minor DC continuity fault - Network Side �

Loop1

DCCONT�NS�2 SA Minor DC continuity fault - Network Side �

Loop2

DCCONT�CS�1 SA Minor DC continuity fault - Customer Side �

Loop1

DCCONT�CS�2 SA Minor DC continuity fault - Customer Side �

Loop2

ACTLPBK�NS SA Minor Facility placed in loopback - Network

Side

Page 147: Asam Tl1 Part 5

Appendix A Alarms and Events

147 / 1663EC 36876 AEAA TCZZA Edition 02

CONDITION DESCRIPTION

DEFAULT

NTFCNCDE

SERVICE

AFFECTING?

CONFERR SA Minor Configuration error

LCD SA Minor Loss of ATM Cell Delineation (see Note)

LPR SA Minor Loss of power at STU�R

SECUERR SA Minor Unable to disable STU�R access

DEVFAIL SA Minor Device Failure

Note These ATM alarms are only supported for STU�C and

STU�R.

E3 Facility Conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RAI ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMAJOR ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁRemote Alarm Indication

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

AIS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁCritical ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁAlarm Indication Signal

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOF ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁCritical ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of framing

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOSÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of Signal/Clock

LCD* SA Critical Loss of cell delineation

ACTLPBK SA Critical Network side in loopback

PLM�P SA Minor Payload type mismatch

PLU SA Minor Stable payload type

UNEQ-P SA Minor Payload unequipped

CELLSIG SA Critical False start�of�cell input signal

OVRFLO SA Critical Buffer (FIFO) overflow

UDRFLO SA Critical Buffer (FIFO) underflow

* These ATM conditions are reported via the E3 facility

Page 148: Asam Tl1 Part 5

Appendix A Alarms and Events

148 / 166 3EC 36876 AEAA TCZZA Edition 02

OC3 facility condition

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁAIS�L

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLine alarm indication signalÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

BERL�HT

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Critical

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Excessive line bit errors

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RFI�L ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Remote failure/defect indication

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

T�CV�LFE ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Excessive far�end block errors

T�CV�S SA Critical Excessive section BIP�8 errors

LOF SA Critical Section loss of frame

LOS SA Critical Section loss of signal

LOC SA Critical Section loss of clock

CELLSIG SA Critical False start�of�cell input signal

OVRFLO SA Critical Buffer (FIFO) overflow

REFCLK SA Critical Reference clock failed

FIFOCLK SA Critical FIFO clock failed

LCD* SA Critical Loss of ATM cell delineation

* These ATM conditions are reported via the OC3 facility

STS3C facility conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁPLM�P

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁNSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSignal Label MismatchÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

PLU

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Signal Label Unstable

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

UNEQ�P ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Path Unequipped

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RFI�P ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Remote Path Failure/Defect Indication

T�CV�P SA Major Excessive Path BIP errors

T�CV�PFE SA Minor Excessive Path Far-End Block Errors

LOP SA Critical STS Loss of Pointer

AIS�P SA Minor Path Alarm Indication Signal

Page 149: Asam Tl1 Part 5

Appendix A Alarms and Events

149 / 1663EC 36876 AEAA TCZZA Edition 02

Signaling channel conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ANISIGCHN�

FAILURE

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Critical

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Failure of network-side Signaling

ChannelÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

UNISIGCHN�

FAILURE

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Failure of user-side Signaling Channel

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

T1-SIGSYS1-PERFÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Performance count threshold exceeded on

Signaling Channel

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

T1-SIGSYS1-SUMÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Performance summary count threshold

exceeded on Signaling Channel

Signaling subsystem conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

T1-SIGSYS1-PERFÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

NSAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Performance count threshold exceeded for

Signaling Subsystem

T3 (DS3) facility conditions

CONDITION

SERVICE

AFFECTING?

DEFAULT

NTFCNCDE DESCRIPTION

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

RAI ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁRemote alarm indication

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

AISÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Alarm indication signalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LOFÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

MajorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

Loss of framingÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLOS

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁCritical

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of signal/clock

ATMFE SA Major ATM DS3 PLCP Far-End Alarm

ATMLOF SA Major ATM DS3 PLCP Loss of Frame

LCD SA Critical Loss of ATM Cell Delineation

Page 150: Asam Tl1 Part 5

Appendix A Alarms and Events

150 / 166 3EC 36876 AEAA TCZZA Edition 02

Page 151: Asam Tl1 Part 5

Appendix B Error Codes

151 / 1663EC 36876 AEAA TCZZA Edition 02

Appendix B Error Codes

An error code is a four�character mnemonic in the response to an

input command that describes why the command cannot be

executed. The error codes are grouped into categories of

� equipage (E)

� input (I)

� multiple error (M)

� privilege (P) and

� status (S).

The following table lists the error codes, their descriptions, and the

Technical Advisory (TA) or Technical Reference (TR) from which the

error codes originate.

ASAM Error Code Summary

CODE DESCRIPTION TA/TR

ENDS Equipage, not equipped with duplex switching TA�200

EQWT Equipage, wrong type TA�200

ICNC Input, command not consistent TA�200

IDNC Input, data not consistent TA�200

IDNV Input, data not valid TA�200

IEAE Input, entity already exists TA�200

IENE Input, entity not exists (does not exist) TA�200

IISP Input, invalid syntax or punctuation TA�200

IITA Input, invalid target identifier - the command contains an invalid TID TA�200

IPEX Invalid extra input parameter TA�200

IPMS Input parameter missing TA�200

IPNC Input parameter not consistent TA�200

IPNV Input parameter not valid TA�200

SAAL Status, already allowed TA�200

SAIN Status, already inhibited TA�200

SARB Status, all system resources busy TA�200

SDNA Status, duplex unit not available TA�200

SDNC Status, data not consistent TA�200

SLEM Status, list exceed maximum - command processing exceeded system

limit

TA�200

Page 152: Asam Tl1 Part 5

Appendix B Error Codes

152 / 166 3EC 36876 AEAA TCZZA Edition 02

CODE TA/TRDESCRIPTION

SNVS Status, not in valid state TA�200

SRCI Status, requested command(s) inhibited TA�200

SROF Status, requested operation failed TA�200

SSRE Status, system resources exceeded - the command exceeded the

system limit on a parameter

TA�200

SSTP Status, command execution stopped - the command execution was

terminated because of a software/hardware problem

TA�200

Page 153: Asam Tl1 Part 5

Appendix C ATM Addressing

153 / 1663EC 36876 AEAA TCZZA Edition 02

Appendix C ATM Addressing

C.1 Introduction

This appendix describes the formats for ATM addresses used in

SVC commands. All four formats specified by the ATM Forum are

supported:

� Data Country Code ATM End System Address (AESA)

� Internation Code Designator AESA

� E.164 AESA

� Native E.164

Unformatted AESA addresses are also supported.

C.2 Data Country Code AESA Format

The format for DCC AESA addresses is:

DCC-idi.hodsp.esi.sel

idi Initial Domain Identifier (3 digit decimal).

The value is a 3�digit Country Code.

hodsp Higher�Order Domain�Specific Part (20

digit hexadecimal). If fewer than 20 digits

are specified, the value is padded with

trailing zeroes.

esi End System Identifier (12 digit

hexadecimal). If fewer than 12 digits are

specified, the value is padded with trailing

zeroes.

sel Selector (2 digit hexadecimal). If fewer than

2 digits are specified, the value is padded

with trailing zeroes.

Page 154: Asam Tl1 Part 5

Appendix C ATM Addressing

154 / 166 3EC 36876 AEAA TCZZA Edition 02

C.3 International Code Designator AESA Format

The format for ICD AESA addresses is:

ICD-idi.hodsp.esi.sel

idi Initial Domain Identifier (4 digit decimal).

The value is a 4�digit International Code

Designator that identifies an international

organization.

hodsp Higher�Order Domain�Specific Part (20

digit hexadecimal). If fewer than 20 digits

are specified, the value is padded with

trailing zeroes.

esi End System Identifier (12 digit

hexadecimal). If fewer than 12 digits are

specified, the value is padded with trailing

zeroes.

sel Selector (2 digit hexadecimal). If fewer than

2 digits are specified, the value is padded

with trailing zeroes.

C.4 E.164 AESA Format

The format for E.164 AESA addresses is:

AE164-idi.hodsp.esi.sel

idi Initial Domain Identifier (1...15 digit

decimal). The value is an E.164 telephone

number.

hodsp Higher�Order Domain�Specific Part (8 digit

hexadecimal). If fewer than 8 digits are

specified, the value is padded with trailing

zeroes.

esi End System Identifier (12 digit

hexadecimal). If fewer than 12 digits are

specified, the value is padded with trailing

zeroes.

sel Selector (2 digit hexadecimal). If fewer than

2 digits are specified, the value is padded

with trailing zeroes.

Page 155: Asam Tl1 Part 5

Appendix C ATM Addressing

155 / 1663EC 36876 AEAA TCZZA Edition 02

C.5 Native E.164 Format

The format for native E.164 addresses is:

AE164-phone

phone E.164 telephone number (1...15 digit

decimal)

C.6 Unformatted AESA Format

The format for unformatted AESA addresses is:

A-address

address AESA address exactly as it is represented

internally (1...15 digit hexadecimal)

Page 156: Asam Tl1 Part 5

Appendix C ATM Addressing

156 / 166 3EC 36876 AEAA TCZZA Edition 02

Page 157: Asam Tl1 Part 5

Appendix D System Access Identifiers

157 / 1663EC 36876 AEAA TCZZA Edition 02

Appendix D System Access Identifiers

This appendix provides information about the System AIDs It first

provides information about the equpment arrangements for:

� Standard Density (SD) systems

� High Density (HD) systems

� Ulta Density (UD) systems.

Then the document lists the Equipment AIDs.

D.1 Standard Density Systems

Figure 1 shows the equipment arrangement for the SD ASAM.

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

– – –

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

NTA

or

EXA

NTA

or

EXB

LT1 LT2LT12 ACU

ATU�R

ATU�R

ATU�R

ATU�R

Shelf Detail

ASAM (NE)

Rack�1 Rack�2 Rack�3 Rack�4

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Figure 1 Standard Density ASAM (NE) Equipment Arrangement

A SD ASAM can have a maximum of 4 racks. Each rack can have

up to 4 shelves.

Note The maximum number of shelves allowed in an ASAM

is 12

Page 158: Asam Tl1 Part 5

Appendix D System Access Identifiers

158 / 166 3EC 36876 AEAA TCZZA Edition 02

D.2 High�Density Systems

Figure 2 shows the equipment arrangement for the HD ASAM.

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

– – –

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

– – –

– – –

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

– – –TAU

or

TEU

LP1 LP2 LP1

6

ACU

NTA

or

EXA

NTA

or

EXBLT1 LT2 LT16

ATU�R

ATU�R

ATU�R

ATU�R

ATU�R

ATU�R

Shelf Detail

ASAM (NE)

Rack�1 Rack�2 Rack�3 Rack�4 Rack�5 Rack�6

Shelf

Shelf Shelf

ShelfShelf

Shelf Shelf

ShelfShelf

Shelf Shelf

Shelf

Figure 2 High Density ASAM (NE) Equipment Arrangement

An HD ASAM can have a maximum of 6 racks. Each rack can up

to 2 shelves.

Note The maximum number of shelves allowed in an ASAM

is 12

Page 159: Asam Tl1 Part 5

Appendix D System Access Identifiers

159 / 1663EC 36876 AEAA TCZZA Edition 02

D.3 Ultra�Density Systems

Figure shows the equipment arrangement for the UD ASAM.

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

– – –

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

– – –

– – –

Shelf Detail

ACU

NTA

or

EXA

NTA

or

EXBLT1 LT2 LT16

ATU�R

ATU�R

ATU�R

ATU�R

ATU�R

ATU�R

Rack�1 Rack�2 Rack�3

ASAM (NE)

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Shelf

Figure 3 Ultra Density ASAM (NE) Equipment Arrangement

An UD ASAM can have a maximum of 3 racks. Each rack can up

to 3 shelves.

Note The maximum number of shelves allowed in an ASAM

is 6 because of the limit on the number (2304) lines.

Page 160: Asam Tl1 Part 5

Racks (RACK)

Shelves (SHELF)

Network TerminationUnits (NT)

Server Units (SERV)

IP Gateway Server(IPGW)

Appendix D System Access Identifiers

160 / 166 3EC 36876 AEAA TCZZA Edition 02

D.4 Equipment Access Identifiers

This sections describes the equipment AIDs used in the A7300

ASAM.

The ASAM may have up to 6 racks. The AID for the racks is:

RACK�rack

where rack is the rack�number.

The ASAM may have up to 2 HD shelves (sub�racks), 3 UD or 4

SD shelves in a rack. The AID for shelves is:

SHELF�rack�shelf

where rack is the rack number and shelf is the shelf

number (1...4).

The NT are always located in the first shelf of the first rack in a

system (ASAM). The primary NT unit is the NTA, while the

secondary or backup unit is the NTB. The AIDs for the NT are:

{NT|NTA|NTB}

Server Units are special boards that use the LT slots in shelf 1 and

which support auxillary services in the ASAM. The AID for the

Server Units is:

SERV�rack�shelf�sv_slot

Note: Presently

Note Server units may only be placed in rack 1, shelf 1. In

this release the only server unit supported is the IP

Gateway type A (IPGWA).

The AID for IP Gateway (IPGW) server units is

IPGW�rack�shelf�sv_slot

Note Server units may only be placed in rack 1, shelf 1

The IPGW server is a two�slot card that must be

planned in a slot�pair.

Slots are paired as 1�2, 3�4, .., 15�16. The sv_slot

used must be the lower slot number in the pair (e.g.,

1 for 1�2, 3 for 3�4, .. 15 for 15�16).

Page 161: Asam Tl1 Part 5

Shelf Extender Units(EX)

Line Termination Units(LT)

Line TerminationApplique Units (LP)

Test Access Unit (TAU)and Test Extender Units

(TEU)

Alarm Control Unit(ACU)

Appendix D System Access Identifiers

161 / 1663EC 36876 AEAA TCZZA Edition 02

All subsequent shelves in the system are configured with Shelf

Extender (EX) units instead NTs. The extender units connect the

shelf to the previous one in daisy�chain fashion. The extender units

correspond to NT units in the first shelf and have primary unit �

EXA, and backup unit EXB. The AIDs for Shelf Extender units are:

{EX|EXA|EXB}�rack�shelf

Note rack=1, shelf=1 is not a valid AID for an Extender

since this location is only used for an NT.

Each shelf in the ASAM supports LT units in LT slots 1..12 for SD

shelves and slots 1..18 for HD shelves. The AIDs for the Line

Termination units are:

LT�rack�shelf�lt_slot

Each LT in the HD shelf is associated with a separate applique unit

that performs LT support functions. The AID for the LP units is:

LP�rack�shelf�lt_slot

Note LP Units are not managed in release 4.2.

The ASAM supports a single TAU for HD systems that is located in

the first system shelf (rack 1, shelf 1). This unit supports external

test access to circuits in the LT. The TAU connects to other shelves

via a daisy�chain connection using the TEUs located in the same

slot in all subsequent shelves in the system. The AIDs for the TAU

TEU are:

TAU

The TAU is always located in rack 1, shelf 1.

TEU�rack�shelf

The TEU is located in shelves other than rack 1, shelf 1.

Note The TAU and TEUs are not managed in release 4.2.

Each shelf has a slot for an ACU. However, only one ACU is

needed for each rack of an ASAM. ACUs may only be installed in

the first shelf of every rack except the first rack. In the first rack the

ACU must be in the same shelf as the NT. The AID is:

ACU�rack�shelf

Page 162: Asam Tl1 Part 5

ATU�R (ATUR)

ADSL Facilities (ADSL)

OC3 and STS3CFacilities

E1 Facilities

E3 Facilities

Appendix D System Access Identifiers

162 / 166 3EC 36876 AEAA TCZZA Edition 02

The ADSL Termination Unit � Remote (ATU�R ) or the ADSL modem

at the customer premises is managed in a limited way by the

ASAM. The ATU�R is identified by the ADSL circuit to which it is

connected via the LT. The AID is:

ATUR�rack�shelf�lt_slot�circuit

D.5 Transport Facility Access Identifiers

This section describes the AIDs associated with the transport

facility.

Each ADSL LT supports ADSL Termination Unit�Central (ATU�C)

modems. Each modem supports a single ADSL line or circuit. The

AID for ADSL lines is:

ADSL�rack�shelf�lt_slot�circuit

Note SD LTs support 4 circuits

HD LTs support 12 circuits

UD LTs support 24 circuits.

The SONET�NT units (NTA and NTB) and SONET�LT units support

corresponding OC3 and STS3C facilities. The AIDs for these

facilities are:

NT Facilities:

{NTOC3|NTOC3A|NTOC3B}

{NTSTS3C|NTSTS3CA|NTSTS3CB}

LT Facilities:

LTOC3�rack�shelf�lt_slot�circuit

LTSTS3C�rack�shelf�lt_slot�circuit

The E1�NT units support corresponding E1 facilities. The AIDs for

the NT E1 facilities are:

NTE1�circuit

LTE1�rack�shelf�lt_slot�circuit

The E3�NT units (NTA and NTB) support corresponding E3

facilities.The AIDs for the NT E3 facilities are:

{NTE3|NTE3A|NTE3B}

Page 163: Asam Tl1 Part 5

DS1 Facilities

DS3 Facilities

SHDSL Facilities

Voice GatewayFacilities

Appendix D System Access Identifiers

163 / 1663EC 36876 AEAA TCZZA Edition 02

The ASAM supports DS1 facilities on DS1�LT cards.The AID for

these DS1 facilities is:

LTT1�rack�shelf�lt_slot�circuit

Note Only HD LTs are supported. Each supports 8 circuits.

The DS3�NT units (NTA and NTB) support corresponding DS3

facilities. The AIDs for the NT DS3 facilities are:

NT Facilities:

{NTT3|NTT3A|NTT3B}

LT Facilities:

LTT3�rack�shelf�lt_slot�circuit

Note DS3�LT units are only supported for HD and UD

systems in release 4.2.

The A7300 ASAM supports SHDSL LT cards. SHDSL facilities in the

LT card are accessed via the following AIDs:

LTSHDSL�rack�shelf�lt_slot�circuit

(SHDSL facility in the LT)

LTSHDSLDEV�rack�shelf�lt_slot�circuit�unit

(A unit in the SHDSL facility in the LT)

where unit = SHDSL unit in a span (1..2)

unit 1 = STU�C

unit 2 = STU�R

LTSHDSLSEG�rack�shelf�lt_slot�circuit�unit�side

(A segment in the SHDSL facility)

where side = Side of the unit:

N � Network Side

C � Customer Side

LTSHDSLSWP�rack�shelf�lt_slot�circuit�unit�side�wirepair

(A specific wire�pair associated with an SHDSL Segment)

where wirepair = The wire�pair in a segment:

1 � Pair�1 (only pair in a 2�wire mode)

2 � Pair�2 (second pair in a 4�wire mode)

The system supports VALT LT cards. Voice gateway facilities in the

LT card are accessed via AID:

LTVOXPORT�rack�shelf�lt_slot�circuit

Page 164: Asam Tl1 Part 5

ATM Port

ATM Virtual Path Link(VPL)

ATM Virtual ChannelLink (VCL)

IMA Group (IMAGRP)

Appendix D System Access Identifiers

164 / 166 3EC 36876 AEAA TCZZA Edition 02

D.6 Miscellaneous Access Identifiers

This section describes various miscellaneous AIDs.

ATM Ports in the NE are identified by the following AIDs:

NTATM

LTATM�rack�shelf�lt_slot�circuit

LTIMAATM�rack�shelf�lt_slot�imagrp

SERVATM�rack�shelf�serv_slot�circuit

Where:

imagrp is the IMA Group number in the LT

serv_slot is the slot number where the Server card is installed.

The Virtual Path Links in the ATM facilities on the NT and the LT

side are identified by the following AIDs:

NTVPL�vpi

LTVPL�rack�shelf�lt_slot�circuit�vpi

Where vpi is the VPI (Virtual Path Identifier) for the VPL.

The Virtual Channel Links in the ATM facilities on the NT and the

LT side are identified by the following AIDs:

NTVCL�vpi�vci

LTVCL�rack�shelf�lt_slot�vpi�vci

Where vpi is the VPI (Virtual Path Identifier), and vci is the VCI

(Virtual Channel Identifier) for the VCL.

The ASAM supports the use of ATM Forum's Inverse Multiplexing

for ATM (IMA) for E1, DS1 and SHDSL facilities. The AIDs for the

IMA Groups are:

NTIMA (for E1 NT)

LTIMA�rack�shelf�lt_slot�imagrp

Where imagrp is the IMA Group number in the card:

1..4 : SD and HD E1 boards

1..8 : HD and UD DS1 boards

1..24 : HD and UD SHDSL boards.

Page 165: Asam Tl1 Part 5

Signaling Channel(SIGCHN)

Signaling Subsystem(SIGSYS)

SVC User (SVCUSR)

IP�Port (IPPORT)

Environment (ENV)

Appendix D System Access Identifiers

165 / 1663EC 36876 AEAA TCZZA Edition 02

The ASAM system supports SVC capability. The AIDs for accessing

Signaling Channels are:

NTSIGCHN

LTSIGCHN�rack�shelf�lt_slot�circuit

LTIMASIGCHN�rack�shelf�lt_slot�imagrp

The ASAM supports SVC capability. The AID for accessing the

Signaling Subsystem is:

SIGSYS

The ASAM supports SVC capability. The AID for accessing an SVC

User is as follows:

<ATM Address>

The addresses are entered via TL1 in one of the following formats:

Native E.164: E164�ddddddddddddddd (1..15 digits)

AESA DCC: DCC�dddF.xxxxxxxxxxxxxxxxxxxx.xxxxxxxxxxxx.xx

AESA ICD: ICD�dddd.xxxxxxxxxxxxxxxxxxxx.xxxxxxxxxxxx.xx

AESA E.164: AE164�dddddddddddddddF.xxxxxxxx.xxxxxxxxxxxx.xx

Unformatted AESA : A�xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx

(2..40 digits)

where:

d = '0' .. '9' (decimal digit)

x = '0' .. 'F' (hexadecimal digit)

F = Optionally specified hexadecimal 'F' digit

The ASAM supports ports for communications via the Internet

Protocol. The following AIDs support ports that can be configured

by the user:

ATM�1 � The first IP�over�ATM port in the NT

NTENET � The IP over Ethernet interface in the NT

The ASAM supports 5 external alarm sensing inputs via the ACU.

These can be customized for any environment alarm. These

environment alarm inputs are identified by:

ENV�<number>

Where <number> is the number of the alarm input from 1..5.

Page 166: Asam Tl1 Part 5

Appendix D System Access Identifiers

166 / 166 3EC 36876 AEAA TCZZA Edition 02

D.7 Generic Group Access Idenfifiers

The ASAM defines some generic AIDs that represent a group

(class) of objects in the NE. These are used in conjunction with

functions that can only be performed on the group or class as a

whole. Example of these functions include changing Alarm

Attributes which are defined for the group. The following generic

group AIDs are supported:

ALL Represents all entities of the type defined by

the command modifier

COM Represents objects that are common or

shared by all entities in the NE

EQPT Represents every equipment in the NE

ADSL Represents every ADSL facility in the NE

OC3 Represents every OC3 facility in the NE

STS3C Represents every STS3C facility in the NE

E1 Represents every E1 facility in the NE

E3 Represents every E3 facility in the NE

T1 Represents every T1/DS1 facility in the NE

T3 Represents every T3/DS3 facility in the NE

SHDSL Represents every SHDSL facility in the NE

IMAGRP Represents every IMA Group entity in the

NE

IMALNK Represents every IMA Link entity in the NE

SIGCHN Represents every signaling channel in the

NE

SIGSYS Represents the Signaling Subsystem in the

NE

IPGW Represents all instances of IP Gateway

server cards