asam tl1 part 5
TRANSCRIPT
3EC 36876 AEAA TCZZA Edition 02
7300 ASAM
TL1 Commands and Messages
Part 5/5
2 / 166 3EC 36876 AEAA TCZZA Edition 02
Status Released
Change Note B D Fa a42761
Short Title TL1 Commands & Messages
All rights reserved. Passing on and copying of thisdocument, use and communication of its contentsnot permitted without written authorization from Alcatel.
Contents
3 / 1663EC 36876 AEAA TCZZA Edition 02
Contents
1 E1 Commands and Messages 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 E1 Commands 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.1 DLT�E1 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.2 ED�E1 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.3 ENT�E1 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.4 OPR�LPBK�E1 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.5 REPT�OPSTAT�E1 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.6 RLS�LPBK�E1 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.7 RTRV�ALM�E1 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.8 RTRV�ATTR�E1 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.9 RTRV�COND�E1 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.10 RTRV�PM�E1 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.11 RTRV�E1 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.12 SET�ATTR�E1 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 E1 Autonomouse Messages 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2.1 REPT ALM E1 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2.2 REPT EVT E1 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 E1 Conditions 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 E1 Monotypes 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 E3 Commands and Messages 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 E3 Commands 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.1 ED�E3 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.2 RTRV�ALM�E3 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.3 RTRV�ATTR�E3 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.4 RTRV�COND�E3 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.5 RTRV�PM�E3 62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.6 RTRV�E3 65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.7 SET�ATTR�E3 68. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 E3 Autonmous Messages 70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.1 REPT ALM E3 70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.2 REPT EVT E3 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 E3 Conditions 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4 E3 Monotypes 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Environmental Commands and Messages 77. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 ENV Commands 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.1 RTRV�ALM�ENV 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.2 RTRV�ATTR�ENV 80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.3 RTRV�COND�ENV 82. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.4 SET�ATTR�ENV 84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
4 / 166 3EC 36876 AEAA TCZZA Edition 02
3.2 ENV Autonomous Messages 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.1 REPT ALM ENV 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Environmental (ENV) Conditions 88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Miscellaneous System Commands 89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 DLT�MEM 90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 ED�SYNCN 92. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 FREE�PORT 94. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4 INIT�LOG 96. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5 INIT�SYS 98. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6 RD�SYNCN 101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7 REPT�OPSTAT�ICON 103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8 REPT�OPSTAT�NE 105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9 RESV�NEXT�PORT 109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.10 RST�MEM 112. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.11 RTRV�CMDSSN 114. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.12 RTRV�HDR 116. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.13 RTRV�LOG 118. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.14 RTRV�MEM 120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.15 RTRV�NE�ALL 122. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.16 RTRV�PORT 126. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.17 RTRV�SYNCN 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.18 SET�DAT 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.19 SET�NE�ALL 132. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.20 SET�SID 135. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.21 STA�CMDSSN 137. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.22 STP�CMDSSN 139. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix A Alarms and Events 141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix B Error Codes 151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix C ATM Addressing 153. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix D System Access Identifiers 157. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
5 / 1663EC 36876 AEAA TCZZA Edition 02
Figures
Figure 1 Standard Density ASAM (NE) Equipment Arrangement 157. . . . . . . . . . . . . .
Figure 2 High Density ASAM (NE) Equipment Arrangement 158. . . . . . . . . . . . . . . . . .
Figure 3 Ultra Density ASAM (NE) Equipment Arrangement 159. . . . . . . . . . . . . . . . . .
Tables
Table 1 E1 Conditions 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2 E1 Monotypes 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3 E3 Conditions 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4 E3 Monotypes 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5 ENV Conditions 88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
6 / 166 3EC 36876 AEAA TCZZA Edition 02
1 E1 Commands and Messages
7 / 1663EC 36876 AEAA TCZZA Edition 02
1 E1 Commands and Messages
This chapter provides information about the E1 commands and
messages. The chapter has the following main parts:
� E1 Commands
� E1 Autonomous Messages
� E1 Conditions
� E1 Monotypes.
Function
Restrictions
Command Format
1 E1 Commands and Messages
8 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1 E1 Commands
This section describes the E1 commands.
1.1.1 DLT�E1
Deletes an existing E1 facility in the NE.
All parameters in this command are position�defined.
DLT-E1:[tid]:aid_e1:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing
lower�case parameters with the values given:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Response Format
Example
Related Command
1 E1 Commands and Messages
9 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* DLT-E1:[tid]:aid_e1:[ctag][:] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* DLT-E1:[tid]:aid_e1:[ctag][:] */ errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix C)
Delete LT E1 circuit located at rack 3, shelf 2, slot 6.
DLT-E1:RALGH:LTE1-3-2-6:42;
RALGH 00-11-24 12:30:43M 42 COMPLD /* DLT-E1:RALGH:LTE1-3-2-6:42 */;
ED�E1
Function
Restrictions
Command Format
1 E1 Commands and Messages
10 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1.2 ED�E1
Edits the provisioning data associated with an E1 facility. It
optionally allows modification of associated ATM interface
parameters if this facility is provisioned in native ATM (non�IMA)
mode.
All parameters in this command are position�defined.
The ATM interface must be provisioned with the ENT�E1 or
ED�ATMPORT commands before ATM parameters are edited.
ED-E1:[tid]:aid_e1:[ctag]:::[e1_nblk]:[pst];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing
lower�case parameters with the values given:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the Nt or LT (1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
1 E1 Commands and Messages
11 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[e1_nblk] An E1 facility parameter block containing one or more of the following named
parameters (separated by commas):
LINETYPE E1 line type. Valid values are:
DSX1E1CRC
DSX1E1
PORTID Port identifier (1...32 characters). Indicates the user to
whom the port is assigned. The following values are
reserved and cannot be used:
AVAILABLE (port is not assigned)
FAILED (port is failed and cannot be assigned)
Also see the RESV�NEXT�PORT and FREE�PORT com�
mands
1 E1 Commands and Messages
12 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[e1_nblk] (cont) The following parameters apply only if the E1 facility directly transports ATM traffic
(ATM mode). For use with IMA, they should be set to null. If no value is specified,
null is assumed.
ATMACCPROF* ATM Access Profile index (1...50). This value deter�
mines the range of values for vpi and vci in several
other commands. The value of ATMACCPROF cannot
be changed while any VPLs or VCLs exist.
ATMACCPROFNM* ATM Access Profile name
CACPROFDN* Connection Admission and Control Profile index for
downstream direction (1...50)
CACPROFDNNM* Connection Admission and Control profile name for
the downstream direction
CACPROFUP* Connection Admission and Control Profile index for
upstream direction (1...50)
CACPROFUPNM* Connection Admission and Control profile name for
the upstream direction
*These parameters should not be used and are only included in this release for
release for backward compatibility, and will not be supported in a later release.
They should be provisioned with the ED�ATMPORT command.
Note: the parameters must have been provisioned using the ENT-IMAGRP and
ED-ATMPORT commands before they can be edited.
QOSCLASS Quality of service of connections on this port. Valid
values are:
CBR (CBR connections only)
UBR (UBR connections only)
CBRUBR (both CBR and UBR connections)
This parameter should not be used and is only included in this release for
backward compatibility. It will be removed from later releases.
[pst] Primary state filter. Valid values are:
IS In�Service
OOS Out�of�Service (OOS�MA is implied)
If no value is specified, this parameter remains unchanged.
Response Format
Example
Related Commands
1 E1 Commands and Messages
13 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* ED-E1:[tid]:aid_e1:[ctag]:::[e1_nblk]:[pst] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* ED-E1:[tid]:aid_e1:[ctag]:::[e1_nblk]:[pst] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Edit circuit 2 on the NT to have a line type of DSX1E1.
ED-E1:RALGH:NTE1-2:42:::LINETYPE=DSX1E1,PORTID=CORWIN;
RALGH 00-11-24 12:30:43M 42 COMPLD /* ED-E1:RALGH:NTE1-2:42:::LIJNETYPE=DSX1E1,PORTID=CORWIN */;
DLT�E1
ENT-E1
RTRV-E1
Function
Restrictions
Command Format
1 E1 Commands and Messages
14 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1.3 ENT�E1
Creates the provisioning data associated with an E1 facility. It also
provisions any associated direct ATM interface or IMA (Inverse
Multiplexing for ATM) group.
All parameters in this command are position�defined.
A circuit can be used in direct ATM (native) mode only if no IMA
group has been defined for the same port (in other words, circuit
and imagrp cannot have the same value). See ENT�IMAGRP.
ENT-E1:[tid]:aid_e1:[ctag]:::e1_nblk:[pst];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access Identifier for the E1 facility. Enter in one of the following formats, replacing
lower�case parameters with the values given:
LTE1�rack�shelf�lt_slot�circuit
NTE1�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT(1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
e1_nblk E1 facility parameter block containing one or more of the following named
parameters (separated by commas):
LINETYPE Type of line interface used. Valid values are:
DSXE1
DSXE1CRC (default)
PORTID Port identifier (1...32 characters). Indicates the user to
whom the port is assigned. The following values are
reserved and cannot be used:
AVAILABLE (port is not assigned)
FAILED (port is failed and cannot be assigned)
1 E1 Commands and Messages
15 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[e1_nblk] (cont) The following parameters apply only if the E1 facility directly transports ATM traffic
(ATM mode). For use with IMA, they should be set to null. If no value is specified,
null is assumed.
ATMACCPROF* ATM Access Profile index (1...50). This value deter�
mines the range of values for vpi and vci in several
other commands. The value of ATMACCPROF cannot
be changed while any VPLs or VCLs exist.
ATMACCPROFNM* ATM Access Profile name
CACPROFDN* Connection Admission and Control Profile index for
downstream direction (1...50)
CACPROFDNNM* Connection Admission and Control profile name for
the downstream direction
CACPROFUP* Connection Admission and Control Profile index for
upstream direction (1...50)
CACPROFUPNM* Connection Admission and Control profile name for
the upstream direction
*These parameters should not be used and are only included in this release for
release for backward compatibility, and will not be supported in a later release.
They should be provisioned with the ED�ATMPORT command.
Note that the parameters must have been provisioned using the ENT-IMAGRP
and ED-ATMPORT commands before they can be edited.
QOSCLASS Quality of service of connections on this port. Valid
values are:
CBR (CBR connections only)
UBR (UBR connections only)
CBRUBR (both CBR and UBR connections)
This parameter should not be used and is only included in this release for
backward compatibility. It will be removed from later releases.
Response Format
1 E1 Commands and Messages
16 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
The following parameter applies only if the E1 facility is to be used with an IMA
group. For use with ATM, it should be set to null. If no value is specified, null is
assumed.
IMAGRP IMA group to which this facility is to be assigned. Valid
values are:
NTIMA (AID of IMA group on NT)
LTIMA�imagrp (AID of IMA group on LT, imagrp =
1..4)
NULL (Do not use IMA; E1 will directly transport ATM)
Note: If an IMA group is specified, it must exist.
Note: For each profile above, either the profile name or the index (not both) may
be specified. If a profile name is specified and two profiles match the name (one
Local and other Network), the Network profile is used.
The E1-NT or E1-LT may use up to 4 E1 facilities with an IMA Group.
Otherwise only one E1 facility may be used to directly transport ATM.
[pst] Primary state filter. Valid values are:
IS In�Service
OOS Out�of�Service (OOS�MA is implied)
If no value is specified, this parameter remains unchanged.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* ENT-E1:[tid]:aid_e1:[ctag]:::e1_nblk:[pst] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* ENT-E1:[tid]:aid_e1:[ctag]:::e1_nblk:[pst] */ errcde;
Example
Related Commands
1 E1 Commands and Messages
17 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Enter E1 circuit 2�2�10�1 on the LT with a line interface type of
DSX1E1, a port ID of FRANKLIN, and an IMA group of NTIMA.
ENT-E1:RALGH:LTE1-2-2-10-1:42:::LINETYPE=DSX1E1,PORTID=FRANKLIN,IMAGRP=NTIMA;
RALGH 00-11-24 12:30:43M 42 COMPLD /*ENT-E1:RALGH:LTE1-2-2-10-1:42:::LINETYPE=DSX1E1,PORTID=FRANKLIN,IMAGRP=NTIMA */;
FREE�PORT
RESV�NEXT�PORT
RTRV�E1
Function
Restrictions
Command Format
1 E1 Commands and Messages
18 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1.4 OPR�LPBK�E1
Places the selected E1 facility in a loopback mode.
� All parameters in this command are position�defined.
� Loopbacks are supported for the near end (NEND) of the
facility only.
� Loopbacks provisioned with this command are maintained
persistently.
� The near end of the facility can also be placed in loopback by
sending E1 in�band loopback control codes. This form of
loopback is not maintained persistently.
� Loopbacks provisioned with this command take priority over
in�band loopbacks.
� Only one loopback at a time is allowed on a facility.
OPR-LPBK-E1:[tid]:aid_e1:[ctag]::,,,[lbktype];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access Identifier for the E1 facility. Valid values are:
NTE1�circuit
LTE1�rack�shelf�lt�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
Response Format
1 E1 Commands and Messages
19 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[lpbktype] Type of loopback. Valid values are:
LINE Loopback facility at the physical line level toward the
facility (default)
PAYLOAD Loopback facility data (payload) toward the facility
TERMINAL Loopback facility data internally toward the NE
If not specified, LINE is assumed
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* OPR-LPBK-E1:[tid]:aid_e1:[ctag]::,,,[lpbktype] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* OPR-LPBK-E1:[tid]:aid_e1:[ctag]::,,,[lpbktype] */ errcde /* error description */;
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Example
Related Command
1 E1 Commands and Messages
20 / 166 3EC 36876 AEAA TCZZA Edition 02
Place NTE1 circuit 2 in payload loopback mode.
OPR-LPBK-E1:RALGH:NTE1-2:40::,,,PAYLOAD;
RALGH 00-11-24 12:30:43M 40 COMPLD /* OPR-LPBK-E1:RALGH:NTE1-2:40::,,,PAYLOAD */;
RLS�LPBK�E1
Function
Restrictions
Command Format
Response Format
1 E1 Commands and Messages
21 / 1663EC 36876 AEAA TCZZA Edition 02
1.1.5 REPT�OPSTAT�E1
Reports current operational parameters for E1 lines.
All parameters in this command are position�defined.
REPT-OPSTAT-E1:[tid]:aid_e1:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access identifier for E1 facility. Enter in the following format, replacing lower�case
parameters with the values given:
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* REPT-OPSTAT-E1:[tid]:aid_e1:[ctag][:] */ “aid_e1:op_e1,value”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* REPT-OPSTAT-E1:[tid]:aid_e1:[ctag][:] */ errcde;
Example
Related Commands
1 E1 Commands and Messages
22 / 166 3EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (1...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_e1 As described for command parameters
op_e1 E1 operational parameter. Values are:
INCELLS Rolling count of cells received on this facility
OUTCELLS Rolling count of cells transmitted on this facility
value The value of the parameter specified in op_adsl.
Report E1 operational parameters for rack 2, shelf 3, slot 6,
circuit 1.
REPT-OPSTAT-E1:RALGH:LTE1-2-3-6-1;
RALGH 00-01-24 12:30:43M 42 COMPLD /* REPT-OPSTAT-IMAGRP:RALGH:LTE1-2-3–6-1:42 */ “LTE1-2-3–6-1:INCELLS,36600” “LTE1-2-3–6-1:OUTCELLS,28800”;
None.
Function
Restrictions
Command Format
1 E1 Commands and Messages
23 / 1663EC 36876 AEAA TCZZA Edition 02
1.1.6 RLS�LPBK�E1
Releases any loopback currently active at the near end of a
specific E1 facility.
All parameters in this command are position�defined.
Provisioned loopbacks (set with the OPR�LPBK�E1 command) and
in�band loopbacks (set by E1 in�band control codes) are both
released.
RLS-LPBK-E1:[tid]:aid_e1:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access identifier for the E1 facility. Valid values are:
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Response Format
Example
Related Command
1 E1 Commands and Messages
24 / 166 3EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RLS-LPBK-E1:[tid]:aid_e1:[ctag][:] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RLS-LPBK-E1:[tid]:aid_e1:[ctag][:] */ errcde /* error description */;
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Release LTE1 circuit 2 from loopback mode.
RLS-LPBK-E1:RALGH:LTE1-2:40;
RALGH 00-11-24 12:30:43M 40 COMPLD /* RLS-LPBK-E1:RALGH:LTE1-2:40 */;
OPR�LPBK�E1
Function
Restrictions
Command Format
1 E1 Commands and Messages
25 / 1663EC 36876 AEAA TCZZA Edition 02
1.1.7 RTRV�ALM�E1
Retrieves current alarms for selected E1 facilities.
All parameters in this command are position�defined.
RTRV-ALM-E1:[tid]:aid_e1:[ctag]::[ntfcde],,[srveff],[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing
lower�case parameters with the values given:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[ntfncde] Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
Grouping is allowed. If no value is specified, ALL is assumed.
[serveff] Service effect. Valid values are:
SA Service affecting
NSA Not service affecting
Grouping is allowed. If no value is specified, ALL is assumed.
Response Format
1 E1 Commands and Messages
26 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[locn] Location of the condition. Valid values are:
NEND Near end
FEND Far end
If no value is specified, ALL is assumed.
[dirn] Direction of the condition. Valid values are:
RCV Receive
TRMT Transmit
If no value is specified, ALL is assumed.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ALM-E1:[tid]:aid_e1:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ “aid_e1[,aid_type]:ntfncde,cond_e1,serveff,,,[locn],[dirn]:[cond_descr]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ALM-E1:[tid]:aid_e1:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ errcde /* error description */;
Example
Related Commands
1 E1 Commands and Messages
27 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_e1 As described for command parameters, except that ALL is not used
aid_type The type of Access Identifier. The value is E1.
ntfncde As described for command parameters, except that ALL is not used
cond_e1 E1 facility condition. Values are as defined in �E1 Conditions", Section 1.3
serveff As described for command parameters, except that ALL is not used
[locn] As described for command parameters
[dirn] As described for command parameters
[cond_descr] Description of alarm conditionas defined in �E1 Conditions", Section 1.3
Retrieve service�affecting critical alarms for NT circuit 2.
RTRV-ALM-E1:RALGH:NTE1-2:42::CR,,SA;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-ALM-E1:RALGH:NTE1-2:42::CR::SA */ “NTE1-2,E1:CR,LOS,SA,,,NEND,RCV,:Loss of Signal/Clock”;
None
Function
Restrictions
Command Format
1 E1 Commands and Messages
28 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1.8 RTRV�ATTR�E1
Retrieves current attributes of E1 facility�related conditions.
All parameters in this command are position�defined.
RTRV-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::[ntfcde],[cond_e1],[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
[aid_all_e1] Access identifier for the all E1 facilities. The value is E1.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[ntfncde] Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NA Not alarmed (reported via REPORT EVENT)
NR Not reported (information is stored in the NE)
Grouping is allowed. If no value is specified, ALL is assumed.
[cond_e1] E1 facility condition. Valid values are described �E1 Conditions", Section 1.3
[locn] Facility location. Valid values are:
NEND Near end
FEND Far end
Only applicable to conditions supporting location. If no value is specified, ALL is
assumed.
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
Only applicable to conditions supporting direction. If no value is specified, ALL is
assumed.
Response Format
Example
Related Commands
1 E1 Commands and Messages
29 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ATTR-E1:[tid]:[aidall_e1]:[ctag]::[ntfncde],[cond_e1],[locn],[dirn]*/ “aid_all_e1[,aid_type]:ntfncde,cond_e1,[locn],[dirn]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ATTR-E1:[tid]:aidall_e1:[ctag]::[ntfncde],[cond_e1],[locn],[dirn] */ errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_all_e1 As described for command parameters, except that ALL is not used
aid_type The type of Access Identifier. The value is E1.
[ntfncde] As described for command parameters, except that ALL is not used
[cond_e1] As described for command parameters
[locn] As described for command parameters
[dirn] As described for command parameters
Retrieve critical attributes for E1 conditions.
RTRV-ATTR-E1:RALGH:E1:42::CR;
RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-ATTR-E1:RALGH:E1:42::CR */ “E1,E1:CR,LOF,NEND,RCV”;
SET�ATTR�E1
Function
Restrictions
Command Format
1 E1 Commands and Messages
30 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1.9 RTRV�COND�E1
Retrieves current conditions of an E1 facility.
All parameters in this command are position�defined.
RTRV-COND-E1:[tid]:aid_e1:[ctag]::[cond_e1],[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access identifier for the E1 facility. Valid values are:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt�slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3
[locn] Facility location. Valid values are:
NEND Near end
FEND Far end
If no value is specified, ALL is assumed.
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
If no value is specified, ALL is assumed.
Response Format
1 E1 Commands and Messages
31 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-COND-E1:[tid]:aid_e1:[ctag]::[cond_e1],[locn],[dirn] */ “aid_e1[,aid_type]:ntfncde,cond_e1,serveff,,,[locn],[dirn],,[cond_descr]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-COND-E1:[tid]:aid_e1:[ctag]::[cond_ds1],[locn] */ errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_e1 As described for command parameters
[aid_type] The type of Access Identifier. The value is E1.
ntfncde Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NA Not alarmed (reported via REPORT EVENT)
NR Not reported (information is stored in the NE)
cond_e1 As described for command parameters, except that ALL is not used
serveff Service effect. Valid values are:
SA Service affecting
NSA Not service affecting
[locn] As described for command parameters, except that ALL is not used
[dirn] As described for command parameters, except that ALL is not used
[cond_descr] Description of alarm condition.
Example
Related Commands
1 E1 Commands and Messages
32 / 166 3EC 36876 AEAA TCZZA Edition 02
Retrieve current conditions for NT circuit 2 facility.
RTRV-COND-E1:RALGH:NTE1-2:42::,,;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-COND-E1:RALGH:NTE1-2:42::,, */ “NTE1-2,E1:CR,LOS,SA,,,NEND,RCV,,Loss Of Signal/Clock”;
None
Function
Restrictions
Command Format
1 E1 Commands and Messages
33 / 1663EC 36876 AEAA TCZZA Edition 02
1.1.10 RTRV�PM�E1
Retrieves E1 performance monitoring data.
All parameters in this command are position�defined.
RTRV-PM-E1:[tid]:aid_e1:[ctag]::[mone1],[monlev],[locn],[dirn],[tmper],[mondat],[montm];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access identifier for the environment. Valid values are:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[mone1] Monitored parameter (Monotype). Valid values are given in �E1 Monotypes,
Section 1.4
[monlev] Threshold level. Enter in the following format:
lev�dirn
lev Level (0...4294967295)
dirn Direction. Valid values are:
UP (Up)
DN (Down)
If no value is specified, 1�UP is assumed.
[locn] Location of the facility. Valid values are:
NEND Near end
FEND Far end
If no value is specified, this parameter is not used for filtering responses.
Response Format
1 E1 Commands and Messages
34 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
If no value is specified, this parameter is not used for filtering responses.
[tmper] Time period. The only valid value is:
15�MIN 15 minutes
If no value is specified, 15�MIN is assumed.
[mondat] Start date for the monitoring period. Valid values are:
mm�dd Month and day
mm Month (1...12)
dd Day (1...31)
ALL All performance monitoring data is retrieved
If no value is specified, today's date is assumed.
[montm] Start time for the monitoring period. Valid values are:
hh�mm Hour and minute
hh Hour (00...23)
mm Minute. Valid values are 0, 15, 30, and 45.
ALL All performance monitoring data is retrieved
If no value is specified, the nearest value to the current time is assumed. Grouping
is allowed.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-PM-E1:[tid]:aid_e1:[ctag]::[mone1],[monlev],[locn],[dirn],[tmper], [mondat],[montm] */ “aid_e1[,aid_type]:mone1,monval,,[locn],,[tmper],[mondat],[montm]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-PM-E1:[tid]:aid_e1:[ctag]::[mone1],[monlev],[locn],[dirn],[tmper], [mondat],[montm] */ errcde;
Example
Related Command
1 E1 Commands and Messages
35 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
aid_e1 As described for command parameters
[aid_type] Type of AID. The value is E1.
mone1 As described for command parameters, except that ALL is not used
monval Measured value for the monitored parameter (0...4294967295)
[locn] As described for command parameters
[dirn] As described for command parameters
[tmper] As described for command parameters
[mondat] As described for command parameters, except that ALL is not used
[montm] As described for command parameters, except that ALL is not used
errcde Error code (See Appendix B)
Retrieve the near�end alarm indication signal count above 4096
for a 15�minute period beginning at 8:30 a.m. on November 10.
RTRV-PM-E1:RALGH:NTE1-3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-PM-E1:RALGH:NTE1-3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30 */ “NTE1-3:CV-L,2015,,NEND,,15-MIN,11-10,08-30”;
RTRV�ALM�E1
Function
Restrictions
Command Format
1 E1 Commands and Messages
36 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1.11 RTRV�E1
Retrieves the provisioning data associated with an E1 facilities.
All parameters in this command are position�defined.
RTRV-E1:[tid]:aid_e1:[ctag]::::[pstf],[sstf];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e1 Access Identifier for the E1 facility. Enter in the following format, replacing
lower�case parameters with the values given:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
Grouping and ranging are allowed.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[pstf] Primary state filter. Valid values are:
IS In�Service
OOS Out�of�Service (OOS�MA, OOS�AU, OOS�AUMA)
AU OOS�AU, OOS�AUMA
MA OOS�MA, OOS�AUMA
If no value is specified, this filter is ignored.
[sstf] Secondary state filter. Valid values are:
LPBK Retrieve looped�back entities only
If no value is specified, this filter is ignored.
Response Format
1 E1 Commands and Messages
37 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-E1:[tid]:aid_e1:[ctag]::::[pstf],[sstf] */ aid_e1::e1_nblk:state,[sst];
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-E1:[tid]:aid_e1:[ctag]::::[pstf],[sstf] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
aid_e1 As described for command parameters
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
e1_nblk E1 facility parameter block containing one or more of the following named
parameters (separated by commas):
LINETYPE Type of line interface used. Values are:
DSX1E1
DSX1E1CRC
PORTID Port identifier (1...32 characters). Indicates the user to
whom the port is assigned. The following values are
reserved and cannot be used:
AVAILABLE (port is not assigned)
FAILED (port has failed and cannot be assigned)
1 E1 Commands and Messages
38 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
e1_nblk
(cont)
The following parameters apply only if the E1 facility directly transports ATM traffic
(ATM mode). For each profile, either the profile name or the profile index (not
both) can be specified. If a profile name matches two profiles (Network and Lo�
cal), the Network profile is used.
ATMACCPROF* ATM Access Profile index (1...50). Default is 1.
ATMACCPROFNM* ATM Access Profile name
CACPROFDN* Connection Admission and Control Profile index for
downstream direction (1...50). Default is 1.
CACPROFDNNM* Connection Admission and Control Profile name for
the downstream direction
CACPROFUP* Connection Admission and Control Profile index for
upstream direction (1...50). Default is 1.
CACPROFUPNM* Connection Admission and Control Profile name for
the upstream direction
*These parameters should not be used and are only included in this release for
release for backward compatibility, and will not be supported in a later release.
They should be provisioned with the ED�ATMPORT command.
QOSCLASS Quality of service of connections on this port. Valid
values are:
CBR (CBR connections only)
UBR (UBR connections only)
CBRUBR (both CBR and UBR connections)
This parameter should not be used and is only included in this release for
backward compatibility. It will be removed from later releases.
The following parameter applies only if the E1 facility is to be used with an IMA
group. Otherwise it is not reported.
IMAGRP IMA group to which this facility is to be assigned.
Values are:
NTIMA (AID of IMA group on NT)
LTIMA�imagrp (AID of IMA group on LT, imagr=1..4)
NULL (Do not use IMA; E1 will directly transport ATM)
pst Primary state. Values are:
IS�NR
OOS�AU
OOS�MA (Transient state. Changes to OOS-AUMA
OOS�AUMA
[sst] Secondary state. Values are:
LPBK Retrieve looped�back entities only
errcde Error code (See Appendix B)
Example
Related Commands
1 E1 Commands and Messages
39 / 1663EC 36876 AEAA TCZZA Edition 02
Retrieve circuit 2 on the NT.
RTRV-E1:RALGH:NTE1-2:42::::;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-E1:RALGH:NTE1-2:42:::: */ NTE1-2::LINETYPE=DSX1E1,CACPROFDN=4,CACPROFUP=3,ATMACCPROF=9,IMAGRP=2:IS-NR,;
ENT�E1
Function
Restrictions
Command Format
1 E1 Commands and Messages
40 / 166 3EC 36876 AEAA TCZZA Edition 02
1.1.12 SET�ATTR�E1
Sets attributes of E1 facility�related alarm conditions.
All parameters in this command are position�defined.
Attributes are common for all E1 facilities.
SET-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::ntfncde,cond_e1,[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NE's SID code is the only other valid value.
[aid_all_e1] Access identifier for all E1 facilities. The value is E1.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
ntfncde Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NA Not alarmed (reported via REPORT EVENT)
NR Not reported (information is stored in the NE)
[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3
[locn] Facility location. Valid values are:
NEND Near end
FEND Far end
Only applicable to conditions supporting location. If no value is
specified, ALL is assumed.
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
Only applicable to conditions supporting direction. If no value is
specified, ALL is assumed.
Response Format
Example
Related Command
1 E1 Commands and Messages
41 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::ntfncde,cond_e1,[locn],[dirn] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* SET-ATTR-E1:[tid]:[aid_all_e1]:[ctag]::ntfncde,cond_e1,[locn],[dirn] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Associate the critical (CR) notification code with the RAI alarm
condition.
SET-ATTR-E1:RALGH:E1:42::CR,RAI;
RALGH 98-11-24 12:30:43M 42 COMPLD /* SET-ATTR-E1:RALGH:E1:42::CR,RAI */;
RTRV�ATTR�E1
Function
Message Format
1 E1 Commands and Messages
42 / 166 3EC 36876 AEAA TCZZA Edition 02
1.2 E1 Autonomouse Messages
This section describes the E1 autonomous messages.
1.2.1 REPT ALM E1
Reports current E1 facility alarms from the NE.
almcode atag REPT ALM E1 “aid_e1:ntfncde,cond_e1,serveff,[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;
Response Parameters
Parameter Explanation
almcde Alarm code. Identifies the severity of the alarm. Values are:
*C Critical alarm
** Major alarm
*^ Minor alarm
A^ Automatic message (typically used to report a cleared
alarm)
atag Automatic tag that indicates the numerical sequence of messages reported
aid_e1 Access identifier for the E1 facility. Values are:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
ntfncde Notification code. Values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
CL Cleared alarm
[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3
serveff Service effect. Values are:
SA Service affecting
NSA Not service affecting
1 E1 Commands and Messages
43 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[ocrdat] Date of occurrence in the following format:
mm�dd Month and day
mm Month (1...12)
dd Day (1...31)
[ocrtm] Time of occurrence in the following format:
hh�mm�ss Hour, minute, and second
hh Hour (00...23)
mm Minute (00...59)
ss Second (00...59)
[locn] Location of the condition. Values are:
NEND Near end
FEND Far end
[dirn] Direction of the condition. Values are:
RCV Receive
TRMT Transmit
[conddescr] Text string of up to 40 characters that describes the alarm condition
Function
Message Format
1 E1 Commands and Messages
44 / 166 3EC 36876 AEAA TCZZA Edition 02
1.2.2 REPT EVT E1
Reports current E1 facility events from the NE.
almcode atag REPT EVT E1 “aid_e1:cond_e1,[condeff],[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;
Response Parameters
Parameter Explanation
almcde Alarm code. Identifies the severity of the alarm. Values are:
A^ Non�alarm message
atag Automatic tag that indicates the numerical sequence of messages reported
aid_e1 Access identifier for the E1 facility. Values are:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
circuit Circuit in the NT or LT (1...4)
[cond_e1] E1 facility condition. Valid values are deined in �E1 Conditions", Section 1.3
[condeff] Effect of the event on the condition reported. Values are:
SC Standing condition raised
CL Standing condition cleared
TC Transient condition
[ocrdat] Date of occurrence in the following format:
mm�dd Month and day
mm Month (1...12)
dd Day (1...31)
[ocrtm] Time of occurrence in the following format:
hh�mm�ss Hour, minute, and second
hh Hour (00...23)
mm Minute (00...59)
ss Second (00...59)
1 E1 Commands and Messages
45 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[locn] Location of the condition. Values are:
NEND Near end
FEND Far end
[dirn] Direction of the condition. Values are:
RCV Receive
TRMT Transmit
[cond_descr] Text string of up to 40 characters that describes the alarm condition
1 E1 Commands and Messages
46 / 166 3EC 36876 AEAA TCZZA Edition 02
1.3 E1 Conditions
Table 1 lists the E1 conditions. In this table, [L] indicates conditions
that support the 'Location' parameter and [D] indicates conditions
that support the 'Direction' parameter
Table 1 E1 Conditions
Condition SERVEFF DEF NTFCNCDE Description
RAI SA Minor Remote Alarm Indication.[L] [D]
AIS SA Minor Alarm Indication Signal.[L] [D]
LOF SA MAJOR Loss of framing.[L] [D]
LOS SA Minor Loss of Signal/Clock.[L] [D]
ACTLPBK SA Minor Facility placed in loopback.[L]
MISMATCH SA Minor Interface does not match configuration.[L]
LCD* SA Minor Loss of ATM Cell Delineation.[L] [D]
LI F+ SA Minor Loss of IMA Frame.[L] [D]
LODS+ SA Minor IMA Link out of Delay Synchronization.[L] [D]
MISCONN+ SA Minor IMA Link Mis-connected.[L] [D]
RFI-IMA+ SA Minor IMA Remote Failure Indication.[L] [D]
FAULT-IMA+ SA Minor IMA Remote Failure Indication.[L] [D]
UNUSABLE�IMA+ SA Minor IMA Link unusable due to far-end behavior.[L] [D]
* These ATM Conditions are only available as "E1 Conditions" in this release for backward compatibility,
and will be removed in a future release They should be retrieved via xxx-ATMPORT commands.
+ IMA Link conditions reported via the E1 facility (For E1's being used as a Link with IMA).
Note DS1 and E1 facilities share alarm conditions. Attribute
changes affect both type of facilities.
1 E1 Commands and Messages
47 / 1663EC 36876 AEAA TCZZA Edition 02
1.4 E1 Monotypes
Table 2 lists the E1 Monotypes. In this table, the following
notations are used:
� Location:
� NE = Near�end of the facility
� FE = Far�end of the facility
� Direction
� RX = Receive
� TX = Transmit.
Table 2 E1 Monotypes
Monotype Location Direction Description
CV-L NE Rx Line Code Violations
ES-L NE + FE Rx Line Errored Seconds
CV-P NE + FE Rx Path Coding Violations
ES-P NE + FE Rx Path Errored Seconds
ESB-P NE + FE Rx Path Errored Seconds - Type B
SES-P NE + FE Rx Path Severely Errored Seconds
UAS-P NE +FE Rx Path Un-Available Seconds
SEFS-P NE + FE Rx Path Severely Errored Framing Seconds
DHECV* NE Rx Discarded Cells Due to HEC Violation
IV-IMA-L+ NE Rx IMA Link ICP Violations
SES-IMA-L+ NE + FE Rx IMA Link Severely Errored Seconds
UAS-IMA-L+ NE + FE Rx IMA Link Un-Available Seconds
UUS-IMA-L+ NE + FE Tx + Rx IMA Link Un-Usable Seconds
FC-IMA-L+ NE + FE Tx + Rx IMA Link Failure Count
OIF-IMA-L+ NE Rx IMA Link Out of IMA Frame Events
STUFF-IMA-L+ NE Rx IMA Link ICP Cell Stuffing Events
* These ATM Montypes are only available as "E1 Montypes" in this release for backward compatibility, and
will be removed in a future release They should be retrieved via xxx-ATMPORT commands.
+ These IMA Link parameters are reported via the underlying E1 facility if it is used as an IMA Link.
1 E1 Commands and Messages
48 / 166 3EC 36876 AEAA TCZZA Edition 02
2 E3 Commands and Messages
49 / 1663EC 36876 AEAA TCZZA Edition 02
2 E3 Commands and Messages
This chapter provides information about the E3 commands and
messages. The chapter has the following main parts:
� E3 Commands
� E3 Autonomous Messages.
� E3 Conditions
� E3 Monotypes.
Function
Restrictions
Command Format
2 E3 Commands and Messages
50 / 166 3EC 36876 AEAA TCZZA Edition 02
2.1 E3 Commands
This section describes the E3 commands.
2.1.1 ED�E3
Edits the provisioning data associated with an E3 facility.
All parameters in this command are position�defined.
ED-E3:[tid]:aid_e3:[ctag]:::[e3_nblk]:[pst];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID
code is the only other valid value.
aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this
is not required. Valid values are:
NTE3�circuit (E3 Facility on the NT sides A and B)
LTE3�rack�shelf�lt_slot�circuit (E3 facility in the LT)
rack Rack number (1...6)
shelf Shelf number (1...2)
lt_slot LT slot number (1...16)
circuit Circuit in the LT (1...4)
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Response Format
2 E3 Commands and Messages
51 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[e3_nblk] Named parameter block for E3. The block consists of one or more of the
following parameters, in any order separated by commas, each followed by an
equal sign and a valid value. If not specified, the values of these parameters
remain unchanged.
ATM access profiles cannot be changed while any VPLs or VCLs exist. The profile
index and profile name for the same entity cannot be specified. If a profile name
matches two profiles (Local and Network), the Network profile is used.
ATMACCPROF* ATM Access Profile index (1...50). This value deter�
mines the range of values for vpi and vci in several
other commands. The value of ATMACCPROF cannot
be changed while any VPLs or VCLs exist.
ATMACCPROFNM* ATM Access Profile name
CACPROFDN* Connection Admission and Control Profile index for
downstream direction (1...50)
CACPROFDNNM* Connection Admission and Control profile name for
the downstream direction
CACPROFUP* Connection Admission and Control Profile index for
upstream direction (1...50)
CACPROFUPNM* Connection Admission and Control profile name for
the upstream direction
*These parameters should not be used and are only included in this release for
release for backward compatibility, and will not be supported in a later release.
They should be provisioned with the ED�ATMPORT command.
[pst] Primary state to be set. Valid values are:
IS In�Service
OOS Out�of�Service (OOS�MA is implied)
If no value is specified, the value of this parameter stays unchanged.
This parameter is not used for the NT
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* ED-E3:[tid]:aid_e3:[ctag]:::[e3_nblk]:[pst] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* ED-E3:[tid]:aid_e3:[ctag]:::[e3_nblk]:[pst] */ aid:ERRCDE=errcde /* error description */;
Example
Related Commands
2 E3 Commands and Messages
52 / 166 3EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
Edit circuit 2 on the NT to use a Connection Admission and
Control Profile index of 9.
ED-E3:RALGH:NTE3:42:::CACPROFUP=9;
RALGH 00-11-24 12:30:43M 42 COMPLD /* ED-E3:RALGH:NTE3:42:::CACPROFUP=9 */;
DLT�E3
RTRV E3
Function
Restrictions
Command Format
2 E3 Commands and Messages
53 / 1663EC 36876 AEAA TCZZA Edition 02
2.1.2 RTRV�ALM�E3
Retrieves current alarms for selected E3 facilities.
All parameters in this command are position�defined.
RTRV-ALM-E3:[tid]:aid_e3:[ctag]::[ntfcde],,[srveff],[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this
is not required. Valid values are:
NTE3 (E3 Facility on the NT sides A and B)
NTE3A (E3 Facility on the NT side A)
NTE3B (E3 Facility on the NT side B)
LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)
rack Rack number (1...6)
shelf Shelf number (1...2)
lt_slot LT slot number (1...16)
circuit Circuit in the LT (1...1)
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
[ntfncde] Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
Grouping is allowed. If no value is specified, ALL is assumed.
[serveff] Service effecting Valid values are:
SA Service affecting
NSA Not service affecting
Grouping is allowed. If no value is specified, ALL is assumed.
Response Format
2 E3 Commands and Messages
54 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[locn] Location of the condition. Valid values are:
NEND Near end
FEND Far end
If no value is specified, ALL is assumed.
[dirn] Direction of the condition. Valid values are:
RCV Receive
TRMT Transmit
If no value is specified, ALL is assumed.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ALM-E3:[tid]:aid_e3:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ “aid_e3[,aid_type]:ntfncde,cond_e3,serveff,,,[locn],[dirn],,[cond_descr]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ALM-E3:[tid]:aid_e3:[ctag]::[ntfncde],,[srveff],[locn],[dirn] */ errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_e3 Only E3NTA is supported.
aid_type The type of Access Identifier. The value is E3.
ntfncde As described for command parameters, except that ALL is not used
Example
Related Commands
2 E3 Commands and Messages
55 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3
serveff As described for command parameters, except that ALL is not used
[locn] As described for command parameters
[dirn] As described for command parameters
[cond_descr] Description of alarm condition as defined in �E3 Conditions", Section 2.3
Retrieve service�affecting critical alarms for NT circuit 2.
RTRV-ALM-E3:RALGH:NTE3-2:42::CR,,SA;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-ALM-E3:RALGH:NTE3-2:42::CR::SA */ “NTE3-2,E3:CR,LOS,SA,,,NEND,RCV,:Loss of Signal/Clock”;
None
Function
Restrictions
Command Format
2 E3 Commands and Messages
56 / 166 3EC 36876 AEAA TCZZA Edition 02
2.1.3 RTRV�ATTR�E3
Retrieves current attributes of E3 facility�related conditions.
All parameters in this command are position�defined.
RTRV-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::[ntfcde],[cond_e3],[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
[aidall_e3] Access identifier for all E3 facilities. The value is E3.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
[ntfncde] Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NA Not alarmed (reported via REPORT EVENT)
NR Not reported (information is stored in the NE)
Grouping is allowed. If no value is specified, ALL is assumed.
cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3
[locn] Facility location. Valid values are:
NEND Near end
FEND Far end
Only applicable to conditions supporting location. If no value is specified, ALL is
assumed.
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
Only applicable to conditions supporting direction. If no value is specified, ALL is
assumed.
Response Format
2 E3 Commands and Messages
57 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::[ntfncde],[cond_e3],[locn],[dirn]*/ “aidall_e3[,aid_type]:ntfncde,cond_e3,[locn],[dirn]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::[ntfncde],[cond_e3],[locn],[dirn]*/ errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
aidall_e3 As described for command parameters, except that ALL is not used
aid_type Type of Access Identifier. The value is E3.
[ntfncde] As described for command parameters, except that ALL is not used
[cond_e3] As defined in �E3 Conditions", Section 2.3
[locn] As described for command parameters
[dirn] As described for command parameters
[cond_descr] Description of alarm condition as defined in �E3 Conditions", Section 2.3
Example
Related Commands
2 E3 Commands and Messages
58 / 166 3EC 36876 AEAA TCZZA Edition 02
Retrieve critical attributes for E3 conditions.
RTRV-ATTR-E3:RALGH:E3:42::CR;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-ATTR-E3:RALGH:E3:42::CR */ “E3,E3:CR,LOF,NEND,RCV”;
SET�ATTR�E3
Function
Restrictions
Command Format
2 E3 Commands and Messages
59 / 1663EC 36876 AEAA TCZZA Edition 02
2.1.4 RTRV�COND�E3
Retrieves current conditions of an E3 facility.
All parameters in this command are position�defined.
RTRV-COND-E3:[tid]:aid_e3:[ctag]::[cond_e3],[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this
is not required. Valid values are:
NTE3 (E3 Facility on the NT sides A and B)
NTE3A (E3 Facility on the NT side A)
NTE3B (E3 Facility on the NT side B)
LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)
rack Rack number (1...6)
shelf Shelf number (1...2)
lt_slot LT slot number (1...16)
circuit Circuit in the LT (1...1)
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3
[locn] Facility location. Valid values are:
NEND Near end
FEND Far end
If no value is specified, ALL is assumed.
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
If no value is specified, ALL is assumed.
Response Format
2 E3 Commands and Messages
60 / 166 3EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-COND-E3:[tid]:aid_e3:[ctag]::[cond_e3],[locn],[dirn] */ “aid_e3[,aid_type]:ntfncde,cond_e3,serveff,,,[locn],[dirn],,[cond_descr]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-COND-E3:[tid]:aid_e3:[ctag]::[cond_e3],[locn],[dirn] */ errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
aid_e3 As described for command parameters
[aid_type] Type of Access Identifier. The value is E3.
ntfncde Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NA Not alarmed (reported via REPORT EVENT)
NR Not reported (information is stored in the NE)
cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3
serveff Service effecting Valid values are:
SA Service affecting
NSA Not service affecting
[locn] As described for command parameters, except that ALL is not used
[dirn] As described for command parameters, except that ALL is not used
[cond_descr] Description of alarm condition as defined in �E3 Conditions", Section 2.3
Example
Related Commands
2 E3 Commands and Messages
61 / 1663EC 36876 AEAA TCZZA Edition 02
Retrieve current conditions for NT circuit 2 facility.
RTRV-COND-E3:RALGH:NTE3-2:42::,,;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-COND-E3:RALGH:NTE3-2:42::,, */ “NTE3-2,E3:CR,LOS,SA,,,NEND,RCV,,Loss Of Signal/Clock”;
None
Function
Restrictions
Command Format
2 E3 Commands and Messages
62 / 166 3EC 36876 AEAA TCZZA Edition 02
2.1.5 RTRV�PM�E3
Retrieves E3 performance monitoring data.
All parameters in this command are position�defined.
RTRV-PM-E3:[tid]:aid_e3:[ctag]::[mone3],[monlev],[locn],[dirn],[tmper],[mondat],[montm];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this
is not required. Valid values are:
NTE3 (E3 Facility on the NT sides A and B)
NTE3A (E3 Facility on the NT side A )
NTE3B (E3 Facility on the NT side B)
LTE3�rack�shelf�lt_slot�circuit (E3 facility in the LT side)
rack Rack number (1...6)
shelf Shelf number (1...2)
lt_slot LT slot number (1...16)
circuit Circuit number (1...1)
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
[mone3] E3 monitored parameter. Valid values are as defined in �E3 Monotypes", section
2.4.
Grouping is allowed. If no value is specified, ALL is assumed.
[monlev] Threshold level. Enter in the following format:
lev�dirn
lev Level (0...4294967295)
dirn Direction. Valid values are:
UP (Up)
DN (Down)
If no value is specified, 1�UP is assumed.
Response Format
2 E3 Commands and Messages
63 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[locn] Location of the facility. Valid values are:
NEND Near end
FEND Far end
If no value is specified, all values are reported.
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
If no value is specified, this parameter is not used for filtering responses.
[tmper] Time period. The only valid value is:
15�MIN 15 minutes
If no value is specified, 15�MIN is assumed.
[mondat] Start date for the monitoring period. Valid values are:
mm�dd Month and day
mm Month (1...12)
dd Day (1...31)
ALL All performance monitoring data is retrieved
If no value is specified, today's date is assumed.
[montm] Start time for the monitoring period. Valid values are:
hh�mm Hour and minute
hh Hour (00...23)
mm Minute. Valid values are 0, 15, 30, and 45.
ALL All performance monitoring data is retrieved
Grouping is allowed. If no value is specified, the nearest value to the current time
is assumed.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-PM-E3:[tid]:aid_e3:[ctag]::[mone3],[monlev],[locn],[dirn],[tmper], [mondat],[montm] */ “aid_e3[,aid_type]:mone3,monval,,[locn],,[tmper],[mondat],[montm]”;
Example
Related Command
2 E3 Commands and Messages
64 / 166 3EC 36876 AEAA TCZZA Edition 02
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-PM-E3:[tid]:aid_e3:[ctag]::[mone3],[monlev],[locn][dirn],[tmper], [mondat],[montm] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
aid_e3 As described for command parameters
[aid_type] Type of AID. The value is E3.
mone3 As described for command parameters, except that ALL is not used
monval Measured value for the monitored parameter (0...4294967295)
[locn] As described for command parameters
[dirn] As described for command parameters
[tmper] As described for command parameters
[mondat] As described for command parameters, except that ALL is not used
[montm] As described for command parameters, except that ALL is not used
errcde Error code (see Appendix B)
Retrieve the near�end line code violation count above 4096 for a
15�minute period beginning at 8:30 a.m. on November 10.
RTRV-PM-E3:RALGH:NTE3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-PM-E3:RALGH:NTE3:42::CV-L,4096-UP,NEND,,15-MIN,11-10,08-30 */ “NTE3:CV-L,2015,,NEND,,15-MIN,11-10,08-30”;
RTRV�ALM�E3
Function
Restrictions
Command Format
Response Format
2 E3 Commands and Messages
65 / 1663EC 36876 AEAA TCZZA Edition 02
2.1.6 RTRV�E3
Retrieves the provisioning data associated with an E3 facilities.
All parameters in this command are position�defined.
RTRV-E3:[tid]:aid_e3:[ctag]::::[pstf];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this
is not required. Valid values are:
NTE3 (E3 Facility on the NT sides A and B)
NTE3A (E3 Facility on the NT side A)
NTE3B (E3 Facility on the NT side B)
LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)
rack Rack number (1...6)
shelf Shelf number (1...2)
lt_slot LT slot number (1...16)
circuit Circuit number (1...1)
[pstf] Primary state filter. Valid values are:
IS In�Service
OOS Out�of�Service (OOS�MA, OOS�AU, OOS�AUMA)
AU OOS�AU, OOS�AUMA
MA OOS�MA, OOS�AUMA
If no value is specified, this filter is ignored.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-E3:[tid]:aid_e3:[ctag]::::[pstf] */ aide3::e3_nblk:state;
2 E3 Commands and Messages
66 / 166 3EC 36876 AEAA TCZZA Edition 02
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-E3:[tid]:aid_e3:[ctag]::::[pstf] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
aid_e3 As described for command parameters
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
[e3_nblk] Named parameter block for E3. The block consists of the following parameters,
each followed by an equal sign and a value.
ATMACCPROF* ATM Access Profile index (1...50). Default is 1.
ATMACCPROFNM* ATM Access Profile name
CACPROFDN* Connection Admission and Control Profile index for
downstream direction (1...50). Default is 1.
CACPROFDNNM* Connection Admission and Control Profile name for
the downstream direction
CACPROFUP* Connection Admission and Control Profile index for
upstream direction (1...50). Default is 1.
CACPROFUPNM* Connection Admission and Control Profile name for
the upstream direction
*These parameters should not be used and are only included in this release for
release for backward compatibility, and will not be supported in a later release.
They should be provisioned with the ED�ATMPORT command.
state Primary state. Values are:
IS�NR
OOS�AU
OOS�MA (Transient state. Changes to OOS-AUMA)
OOS�AUMA
errcde Error code (see Appendix B)
Example
Related Command
2 E3 Commands and Messages
67 / 1663EC 36876 AEAA TCZZA Edition 02
Retrieve E3 provisioning data.
RTRV-E3:RALGH:NTE3:42;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-E3:RALGH:NTE3:42 */ NTE3::CELLMAPNG=PLCP_SCRAM,CRDECPLNG=IDLE,OOFDETECT=3OF16BITS, LINEBLDOUT=ENABLED,CACPROFUP=14,ATMACCPROF=9:IS-NR;
ENT�E3
Function
Restrictions
Command Format
2 E3 Commands and Messages
68 / 166 3EC 36876 AEAA TCZZA Edition 02
2.1.7 SET�ATTR�E3
Sets attributes of E3 facility�related alarm conditions. Attributes are
common for all E3 facilities.
All parameters in this command are position�defined.
SET-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::ntfncde,cond_e3,[locn],[dirn];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NE's SID code is the only other valid value.
[aid_all_e3] Access identifier for all E3 facilities. The value is E3.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
ntfncde Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NA Not alarmed (reported via REPORT EVENT)
NR Not reported (information is stored in the NE)
cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3
[locn] Facility location. Valid values are:
NEND Near end
FEND Far end
Only applicable to conditions supporting location. If no value is specified, ALL is
assumed.
[dirn] Signal direction. Valid values are:
RCV Receive
TRMT Transmit
Only applicable to conditions supporting direction. If no value is specified, ALL is
assumed.
Response Format
Example
Related Command
2 E3 Commands and Messages
69 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::ntfncde,cond_e3,[locn],[dirn] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* SET-ATTR-E3:[tid]:[aid_all_e3]:[ctag]::ntfncde,cond_e3,[locn],[dirn] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
Associate the critical (CR) notification code with the RAI alarm
condition.
SET-ATTR-E3:RALGH:E3:42::CR,RAI;
RALGH 00-11-24 12:30:43M 42 COMPLD /* SET-ATTR-E3:RALGH:E3:42::CR,RAI */;
RTRV�ATTR�E3
Function
Message Format
2 E3 Commands and Messages
70 / 166 3EC 36876 AEAA TCZZA Edition 02
2.2 E3 Autonmous Messages
This section describes the E3 autonomous messages.
2.2.1 REPT ALM E3
Reports current E3 facility alarms from the NE.
almcode atag REPT ALM E3 “aid_e3:ntfncde,cond_e3,serveff,[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;
Response Parameters
Parameter Explanation
almcde Alarm code. Identifies the severity of the alarm. Values are:
*C Critical alarm
** Major alarm
*^ Minor alarm
A^ Automatic message (typically used to report a cleared
alarm)
atag Automatic tag that indicates the numerical sequence of messages reported
aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this
is not required. Valid values are:
NTE3 (E3 Facility on the NT sides A and B)
NTE3A (E3 Facility on the NT side A)
NTE3B (E3 Facility on the NT side B)
LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)
rack Rack number (1...6)
shelf Shelf number (1...2)
lt_slot LT slot number (1...16)
circuit Circuit number (1...1)
ntfncde Notification code. Values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
CL Cleared alarm
cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3
2 E3 Commands and Messages
71 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
serveff Service effecting Values are:
SA Service affecting (Immediate action required)
NSA Not service affecting
[ocrdat] Date of occurrence in the following format:
mm�dd Month and day
mm Month (1...12)
dd Day (1...31)
[ocrtm] Time of occurrence in the following format:
hh�mm�ss Hour, minute, and second
hh Hour (00...23)
mm Minute (00...59)
ss Second (00...59)
[locn] Location of condition. Values are:
NEND Near end
FEND Far end
[dirn] Direction of condition. Values are:
RCV Receive
TRMT Transmit
[conddescr] Description of condition (1...40 characters)
Function
Message Format
2 E3 Commands and Messages
72 / 166 3EC 36876 AEAA TCZZA Edition 02
2.2.2 REPT EVT E3
Reports current E3 facility events from the NE.
almcode atag REPT EVT E3 “aid_e3:cond_e3,[condeff],[ocrdat],[ocrtm],[locn],[dirn]:[conddescr]”;
Response Parameters
Parameter Explanation
almcde Alarm code. Identifies the severity of the alarm. Values are:
A^ Non�alarm message
atag Automatic tag that indicates the numerical sequence of messages reported
aid_e3 Access Identifier for the E3 facility. The value can be preceded with AID=, but this
is not required. Valid values are:
NTE3 (E3 Facility on the NT sides A and B)
NTE3A (E3 Facility on the NT side A)
NTE3B (E3 Facility on the NT side B)
LTE3�rack�shelf�lt_slot�circuit (E3 facility on the LT side)
rack Rack number (1...6)
shelf Shelf number (1...2)
lt_slot LT slot number (1...16)
circuit Circuit number (1...1)
cond_e3 E3 facility condition. Values are as defined in �E3 Conditions", Section 2.3
[condeff] Effect of event on condition reported. Values are:
SC Standing condition raised
CL Standing condition cleared
TC Transient condition
2 E3 Commands and Messages
73 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
[ocrdat] Date of occurrence in the following format:
mm�dd Month and day
mm Month (1...12)
dd Day (1...31)
[ocrtm] Time of occurrence in the following format:
hh�mm�ss Hour, minute, and second
hh Hour (00...23)
mm Minute (00...59)
ss Second (00...59)
[locn] Location of condition. Values are:
NEND Near end
FEND Far end
[dirn] Direction of condition. Values are:
RCV Receive
TRMT Transmit
[cond_descr] Description of the alarm condition (1...40 characters)
2 E3 Commands and Messages
74 / 166 3EC 36876 AEAA TCZZA Edition 02
2.3 E3 Conditions
Table 3 lists the E3 conditions. In this table, [L] indicates conditions
that support the 'Location' parameter and [D] indicates conditions
that support the 'Direction' parameter
Table 3 E3 Conditions
Condition SERVEFF DEF NTFCNCDE Description
RAI SA Major Remote Alarm Indication.[L] [D]
AIS SA Critical Alarm Indication Signal.[L] [D]
LOF SA Critical Loss of framing.[L] [D]
LOS SA Critical Loss of Signal/Clock.[L] [D]
LCD* SA Critical Loss of ATM Cell Delineation.[L] [D]
ACTLPBK SA Critical Network Side in Loopback[L] [D]
PLM�P SA Minor Payload Type Mismatch[L] [D]
PLU SA Minor Stable Payload Type[L] [D]
UNEQ�P SA Minor Payload Unequipped[L] [D]
CELLSIG SA Critical False start�of�cell input signal [L][D]
OVRFLO SA Critical Buffer (FIFO) overflow [L][D]
UDRFLO SA Critical Buffer (FIFO) underflow [L] [D]
* These ATM Conditions are reported via the E3 facility.
2 E3 Commands and Messages
75 / 1663EC 36876 AEAA TCZZA Edition 02
2.4 E3 Monotypes
Table 4 lists the E3 Monotypes. In this table, the following
notations are used:
� NE = Near�end of the facility
� FE = Far�end of the facility
� RX = Receive.
Table 4 E3 Monotypes
Monotype Location Direction Description
CV�L NE RX Line Code Violations
ES�L NE RX Line Errored Seconds
ESP�P NE RX P-Bit Errored Seconds
SESP�P NE RX P-Bit Severely Errored Seconds
UASP�P NE RX P-Bit Un-Available Seconds
ESCP�P NE + FE RX CP-Bit Errored Seconds
SESCP�P NE + FE RX CP-Bit Severely Errored Seconds
UASCP�P FE RX CP-Bit Un-Available Seconds
SAS�P NE RX Severely Errored Framing Seconds
DHECV* NE RX Discarded Cells Due to HEC Violation
* These ATM monotypes are reported via the E3 facility.
2 E3 Commands and Messages
76 / 166 3EC 36876 AEAA TCZZA Edition 02
3 Environmental Commands and Messages
77 / 1663EC 36876 AEAA TCZZA Edition 02
3 Environmental Commands and Messages
This chapter provides information about the Environmental (ENV)
commands and messages. The chapter has the following main
parts:
� ENV Commands
� ENV Autonomous Messages.
� ENV Conditions.
Function
Restrictions
Command Format
Response Format
3 Environmental Commands and Messages
78 / 166 3EC 36876 AEAA TCZZA Edition 02
3.1 ENV Commands
This section describes the ENV commands.
3.1.1 RTRV�ALM�ENV
Retrieves current environment alarms.
All parameters in this command are position�defined.
RTRV-ALM-ENV:[tid]:aid_env:[ctag]::[ntfcde],;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_env Access identifier for the environment. Enter in the following format, replacing
lower�case parameters with the values given:
ENV�<number>
<number> 1...5
Grouping and ranging are allowed. ALL may be used.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[ntfncde] Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
Grouping and ranging are allowed. If no value is specified, ALL is assumed.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ALM-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ “aid_env:ntfncde,cond_env”;
Example
Related Commands
3 Environmental Commands and Messages
79 / 1663EC 36876 AEAA TCZZA Edition 02
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ALM-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_env As described for command parameters, except that ALL is not used
ntfncde As described for command parameters, except that ALL is not used
cond_env Environment�related alarm condition. Values are as defined in �ENV Conditions",
Section 3.3
Retrieve ADSL alarms for environment 4.
RTRV-ALM-ENV:RALGH:ENV-4:42:::,,;
RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-ALM-ADSL:RALGH:ENV-4:42:::,, */ “ENV:CR,MISC,SA”;
None
Function
Restrictions
Command Format
Response Format
3 Environmental Commands and Messages
80 / 166 3EC 36876 AEAA TCZZA Edition 02
3.1.2 RTRV�ATTR�ENV
Retrieves current attributes of environment�related conditions.
All parameters in this command are position�defined.
RTRV-ATTR-ENV:[tid]:aid_env:[ctag]::[ntfcde];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_env Access identifier for the environment. Enter in the following format, replacing
lower�case parameters with the values given:
ENV�<number>
<number> 1...5
Grouping and ranging are allowed. ALL may be used.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
[ntfncde] Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NR Not reported (information is stored in the NE)
Grouping is allowed. If no value is specified, ALL is assumed.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-ATTR-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ “aid_env,aid_type:ntfncde,cond_env”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-ATTR-ENV:[tid]:aid_env:[ctag]::[ntfncde] */ errcde;
Example
Related Commands
3 Environmental Commands and Messages
81 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_env As described for command parameters, except that ALL is not used.
aid_type The type of Access Identifier. The value is ENV.
ntfncde Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NA Not alarmed (reported via REPORT EVENT)
NR Not reported (information is stored in the NE)
cond_env Environment�related alarm condition. Values are as defined in �ENV Conditions",
Section 3.3
Retrieve critical attributes for environment 4.
RTRV-ATTR-ENV:RALGH:ENV-4:42::CR;
RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-ATTR-ENV:RALGH:ENV-4:42::CR */ “ENV-4,ENV:CR,MISC”;
SET�ATTR�ENV
Function
Restrictions
Command Format
Response Format
3 Environmental Commands and Messages
82 / 166 3EC 36876 AEAA TCZZA Edition 02
3.1.3 RTRV�COND�ENV
Retrieves current conditions associated with an environmental
alarm input.
All parameters in this command are position�defined.
RTRV-COND-ENV:[tid]:aid_env:[ctag]::[cond_env];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
aid_env Access identifier for an environment. The value can be preceded with AID=, but
this is not required. Enter in the following formats, replacing lower�case
parameters with the values given:
ENV�<number>
<number> 1...5
Grouping and ranging are allowed. ALL may be used.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
cond_env Environment�related alarm condition. Values are as defined in �ENV Conditions",
Section 3.3
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-COND-ENV:[tid]:aid_env:[ctag]::[cond_env] */ “aid_env[,aid_type]:ntfncde,cond_env,,,,,,,[cond_descr]”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-COND-ENV:[tid]:aid_env:[ctag]::[cond_env] */ errcde;
Example
Related Commands
3 Environmental Commands and Messages
83 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (two digits), month, and day
hh:mm:ss Hour (00�23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
aid_env As described for command parameters, except that ALL is not used
[aid_type] Type of Access Identifier. The value is ENV.
[ntfncde] Notification code. Values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NR Not reported (information is stored in the NE)
cond_env As described for command parameters, except that ALL is not used
[cond_descr] Description of alarm condition (1...40 characters)
Retrieve current condition of environment number 4.
RTRV-COND-ENV:RALGH:ENV-4:42::;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-COND-ENV:RALGH:ENV-4:42:: */ “ENV-4:MN,MISC,NSA,,,,,,Miscellaneous Environment Alarm”;
None
Function
Restrictions
Command Format
Response Format
3 Environmental Commands and Messages
84 / 166 3EC 36876 AEAA TCZZA Edition 02
3.1.4 SET�ATTR�ENV
Sets the attributes of environment alarm conditions.
All parameters in this command are position�defined.
SET-ATTR-ENV:[tid]:aid_env:[ctag]::ntfncde;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NE's SID code is the only other valid value.
aid_env Access identifier for the environment. Enter in the following format, replacing
lower�case parameters with the values given:
ENV�<number>
<number> 1...5
Grouping and ranging are allowed. ALL may be used.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
ntfncde Notification code. Valid values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
NR Not reported (information is stored in the NE)
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-ATTR-ENV:[tid]:aid_env:[ctag]::ntfncde */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* SET-ATTR-ENV:[tid]:aid_env:[ctag]::ntfncde */ errcde;
Example
Related Command
3 Environmental Commands and Messages
85 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Associate the critical (CR) notification code with alarm conditions
on environment 4.
SET-ATTR-ENV:RALGH:ENV-4:42::CR;
RALGH 98-11-24 12:30:43M 42 COMPLD /* SET-ATTR-ENV:RALGH:ENV-4:42::CR */;
RTRV�ATTR�ENV
Function
Message Format
3 Environmental Commands and Messages
86 / 166 3EC 36876 AEAA TCZZA Edition 02
3.2 ENV Autonomous Messages
This section describes the ENV autonmous messages.
3.2.1 REPT ALM ENV
Reports current environment alarms from the NE.
almcode atag REPT ALM ENV “aid_env:ntfncde,cond_env,ocrdat,ocrtm,[conddescr]”;
Response Parameters
Parameter Explanation
almcde Alarm code. Identifies the severity of the alarm. Values are:
*C Critical alarm
** Major alarm
*^ Minor alarm
A^ Automatic message (typically used to report a cleared
alarm)
atag Automatic tag that indicates the numerical sequence of messages reported
aid_env Access identifier for the environment in the following format:
ENV�<number>
<number> 1...5
ntfncde Notification code. Values are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
CL Cleared alarm
3 Environmental Commands and Messages
87 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
cond_env Environment condition. The value is:
MISC Miscellaneous environment alarm
ocrdat Date of occurrence in the following format:
mm�dd Month and day
mm Month (1...12)
dd Day (1...31)
ocrtm Time of occurrence in the following format:
hh�mm�ss Hour, minute, and second
hh Hour (00...23)
mm Minute (00...59)
ss Second (00...59)
[conddescr] Text string of up to 40 characters that describes the alarm condition
3 Environmental Commands and Messages
88 / 166 3EC 36876 AEAA TCZZA Edition 02
3.3 Environmental (ENV) Conditions
Table 5 lists the ENV conditions.
Table 5 ENV Conditions
Condition SERVEFF DEF NTFCNCDE Description
MISC ** NSA NR Miscellaneous Environment Alarm
Note: There are 5 miscellaneous alarms corresponding to AIDs (ENV�1..5).
4 Miscellaneous System Commands
89 / 1663EC 36876 AEAA TCZZA Edition 02
4 Miscellaneous System Commands
This chapter provides information about the Miscellaneous System
commands.
Function
Restrictions
Command Format
4 Miscellaneous System Commands
90 / 166 3EC 36876 AEAA TCZZA Edition 02
4.1 DLT�MEM
Deletes a software package from the NE.
In this release, only one action is supported: deletion of the
backup version of the NE provisioning database that is created
after a successful software migration. This is the database used by
the RST�MEM command. Once the database is deleted, the restore
operation becomes impossible.
All parameters in this command are position�defined.
DLT-MEM:[tid]:aid_com:[ctag]::swpkg;
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID
code is the only other valid value.
aid_com Access Identifier for common equipment. The value is COM.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
swpkg Software package to be deleted. The value is BACKUPDB (backup version of the
provisioning database.
Response Format
Example
Related Command
4 Miscellaneous System Commands
91 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* DLT-MEM:[tid]:aid_com:[ctag]::swpkg */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* DLT-MEM:[tid]:aid_com:[ctag]::swpkg */ errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
Delete the backup version of the provisioning database.
DLT-MEM:RALGH:COM:42::BACKUPDB;
RALGH 00-11-24 12:30:43M 42 COMPLD /* DLT-MEM:RALGH:COM:42::BACKUPDB */;
RST�MEM
Function
Restrictions
Command Format
4 Miscellaneous System Commands
92 / 166 3EC 36876 AEAA TCZZA Edition 02
4.2 ED�SYNCN
Configures the reference source for synchronization of the NE
clocks.
All parameters in this command are position�defined.
ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
aid_syncn AID of the NE clock. The value is CLKSRCNT (default).
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
syncn_nblk Named parameter block for SYNCN. The block consists of the following
parameter, followed by an equal sign and a valid value.
PRICREF Primary reference source for synchronizing the clock.
Valid values are:
LOOP (Loop timing recovered from network side facili�
ty)
LOCAL (Local oscillator on NT board)
REDNT (Local oscillator on redundant NT board)
If not specified, the value of this parameter remains unchanged.
Response Format
Example
Related Commands
4 Miscellaneous System Commands
93 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (two digits), month, and day
hh:mm:ss Hour (00�23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
Configure the NE clock to use the BITS clock as its primary
reference source.
ED-SYNCN:RALGH:CLKSRCNT:42:::PRICREF=LOCAL;
RALGH 99-11-24 12:30:43M 42 COMPLD /* ED-SYNCN:RALGH:CLKSRCNT:42:::PRICREF=LOCAL */;
DLT�SYNCN
ENT�SYNCN
Function
Restrictions
Command Format
4 Miscellaneous System Commands
94 / 166 3EC 36876 AEAA TCZZA Edition 02
4.3 FREE�PORT
Frees a port previously assigned to a user (by ED�ADSL,
ED�SHDSL, ED�E1, or RESV-NEXT�PORT).
Note User ports can be assigned to a user/customer, or be
free (available) for assignment. Assignment is based on
the value of the PORTID parameter associated with the
PORT. A specific port may be assigned using the
ED�(ADSL/SHDSL) commands, or any free (available)
port may be requested using the RESC�NEXT�PORT
command. Assigned ports may be freed (un�assigned)
using the FREE�PORT command.
Port assignment is independent of the state (faulty or otherwise)
and presence of connections on the port. You must verify the
condition of the port before freeing it.
All parameters in this command are position�defined.
FREE-PORT:[tid]:port_aid:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
port_aid Access identifier for the port. Enter in one of the following formats, replacing
lower�case parameters with the values given:
ADSL�rack�shelf�lt_slot�circuit
LTSHDSL�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4 for ADSL, 1...3 for SHDSL)
lt_slot LT slot number (1...16)
circuit Circuit number in LT (1...24)
Response Format
Example
Related Commands
4 Miscellaneous System Commands
95 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* FREE-PORT:[tid]:port_aid:[ctag][:] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* FREE-PORT:[tid]:port_aid:[ctag][:] */ aid:ERRCDE=errcde /* error description */;
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (1...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Free port ADSL�1�3�8�2.
FREE-PORT:RALGH:ADSL-1-3-8-2:40;
RALGH 00-01-24 12:30:43M 40 COMPLD /* FREE-PORT:RALGH:ADSL-1-3-8-2:40 */;
ED�ADSL
ED�T1
RESV�NEXT�PORT
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
96 / 166 3EC 36876 AEAA TCZZA Edition 02
4.4 INIT�LOG
Initializes selected system log(s).
All parameters in this command are position�defined.
INIT-LOG:[tid]::[ctag]::lognms;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
lognms Names of logs to be initialized. The only supported value is SECURITY.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* INIT-LOG:[tid]::[ctag]::lognms */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* INIT-LOG:[tid]::[ctag]::lognms */ errcde;
Example
Related Command
4 Miscellaneous System Commands
97 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Initialize the SECURITY log.
INIT-LOG:RALGH::40::SECURITY;
RALGH 98-11-24 12:30:43M 40 COMPLD /* INIT-LOG:RALGH::40::SECURITY */;
RTRV�LOG
Function
Restrictions
Command Format
4 Miscellaneous System Commands
98 / 166 3EC 36876 AEAA TCZZA Edition 02
4.5 INIT�SYS
Initializes or resets selected subsystems in the NE.
All parameters in this command are position�defined.
To restore persistent database, do the following:
a) Use STA�CMDSSN to start a command session.
b) Enable download by using SET�NE�ALL with
MEMDNLD=ENABLED.
c) Use TFTP to download the database file.
d) Restart the system by using INIT�SYS with INIT_MODE=4.
e) Use STP�CMDSSN to stop the command session.
INIT-SYS:[tid]:aid_proc:[ctag]::init_mode;
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID
code is the only other valid value.
aid_proc Identifier of the processor to be initialized. Grouping and ranging are not
allowed. Valid values are:
NTA Network Termination Unit�A
NTB Network Termination Unit�B
LT�rack�shelf�lt_slot Processor in LT unit
SERV�rack�shelf�serv_slot Processor in Server
where
SYSTEM Entire system
rack Rack number (1...6)
shelf Shelf number (1...4)
lt_slot LT slot number (1...16)
Serv_slot Server slot number (1...16)
No grouping or ranging is allowed
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Response Format
4 Miscellaneous System Commands
99 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
init_mode Mode of initialization. Valid values are:
0 Emergency restart for active NT only*
1 Initialize with self�test
2 Initialize without self�test
3 Complete reset (aid_proc=SYSTEM only). Removes all
persistent data from system.
4 Restart using downloaded persistent database
(aid_proc=SYSTEM only) (see Restrictions)
ATTENTION* = To be used only if a normal restart using the values 1 to
4 is not successful.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* INIT-SYS:[tid]:aid_proc:[ctag]::init_mode */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* INIT-SYS:[tid]:aid_proc:[ctag]::init_mode */ aid:ERRCDE=errcde /* error description */;
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
Example
Related Commands
4 Miscellaneous System Commands
100 / 166 3EC 36876 AEAA TCZZA Edition 02
Perform a complete reset of the NTA unit.
INIT-SYS:RALGH:NTA:40::3;
RALGH 00-11-24 12:30:43M 40 COMPLD /* INIT-SYS:RALGH:NTA:40::3 */;
None
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
101 / 1663EC 36876 AEAA TCZZA Edition 02
4.6 RD�SYNCN
Retrieves the current reference source for synchronization of the
NE clock.
All parameters in this command are position�defined.
RD-SYNCN:[tid]:[aid_syncn]:[ctag][:];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
aid_syncn AID of the NE clock. The value is CLKSRCNT.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RD-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ aid_syncn,cref;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RD-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ errcde;
Example
Related Commands
4 Miscellaneous System Commands
102 / 166 3EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (two digits), month, and day
hh:mm:ss Hour (00�23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
aid_syncn As described for command parameters
cref Primary reference source for synchronizing the clock. Values are:
PRI�LOOP Loop timing recovered from network side facility
PRI�LOCAL Local oscillator on NT board
PRI�REDNT Local oscillator on redundant NT board
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
Retrieve the NE clock source.
RD-SYNCN:RALGH:CLKSRCNT:42;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RD-SYNCN:RALGH:CLKSRCNT:42 */
CLKSRCNT,PRI-LOCAL;
ED�SYNCN
RTRV�SYNCN
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
103 / 1663EC 36876 AEAA TCZZA Edition 02
4.7 REPT�OPSTAT�ICON
Reports current operational parameters of the IQ�bus Controller
(ICON) subsystem of the ASAM.
All parameters in this command are position�defined.
REPT-OPSTAT-ICON:[tid]:[aid_com]:[ctag][:];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
[aid_com] Access Identifier for common equipment. The value is COM.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* REPT-OPSTAT-ICON:[tid]:[aid_com]:[ctag][:] */ “aid_com:op_icon,value”;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* REPT-OPSTAT-ICON:[tid]:[aid_icon]:[ctag][:] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00�23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
Example
Related Commands
4 Miscellaneous System Commands
104 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
aid_icon As described for command parameters
op_icon ICON subsystem operational parameter. Values are:
R<r>S<s> Status bitmap for shelf <s> in Rack <r>: n (1...8) in
each rack.
<r> Rack Number (1...6)
<s> Shelf (1...4)
If shelf n is not present in a rack, the value is a space
character. Otherwise, the value is a bitmap consisting
of three bits as follows:
Bit 0: LT equipped (1=yes, 0=no)
Bit 1: LT enabled (1=yes, 0=no)
Bit 2: LT powered down (1=yes, 0=no)
ORDER Sequence of shelves in the extender chain. The value is
a series of 8�digit hexadecimal numbers, in extender
chain order. The 5 least significant bits of each
number represent the settings of the backplane straps
for the corresponding shelf.
value Value of the parameter specified in op_icon
Report ICON subsystem operational parameters.
REPT-OPSTAT-ICON:RALGH:;
RALGH 99-11-24 12:30:43M 42 COMPLD /* REPT-OPSTAT-ICON:RALGH::42 */ “COM:SHELF1,\”300000000000 \“” “COM:SHELF2,\” \“” “COM:SHELF3,\” \“” “COM:SHELF4,\” \“” “COM:SHELF5,\” \“” “COM:SHELF6,\” \“” “COM:SHELF7,\” \“” “COM:SHELF8,\” \“” “COM:ORDER,\” : 00 \””;
None.
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
105 / 1663EC 36876 AEAA TCZZA Edition 02
4.8 REPT�OPSTAT�NE
Reports current operational parameters for the system.
All parameters in this command are position�defined.
REPT-OPSTAT-NE:[tid]:[aid_com]:[ctag][:];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID
code is the only other valid value.
[aid_com] Access Identifier for common equipment. The value is COM.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Normal Response
tid yy-mm-dd hh:mm:ssM c COMPLD /* REPT-OPSTAT-NE:[tid]:[aid_com]:[ctag][:] */ “aid_com:op_ne,value” “aid_com:op_ne,value” . . .;
Error Response
tid yy-mm-dd hh:mm:ssM c DENY /* REPT-OPSTAT-NE:[tid]:[aid_com]:[ctag][:] */ aid:ERRCDE=errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (2 digits), month, and day
hh:mm:ss Hour (00...23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
4 Miscellaneous System Commands
106 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
aid_com As described for command parameters
op_ne,value Name and value (separated by a comma) of a system operational parameter.
Parameters are:
ACTCHN Currently active chain (side). Values are:
CHAINA (Chain A active)
CHAINB (Chain B active)
EQPTPRAC Equipment practice for this NE. Values are:
LAUS (Large�shelf US model)
MAUS (Mini�RAM US model)
LAEU (Large�shelf European model)
MAEU (Mini�RAM European model)
OTHER (Unknown equipment practice)
EXTCHALEN Length of extender chain, side A (integer 1...N)
EXTCHBLEN Length of extender chain, side B (integer 1...N)
FACASTATUS Status of NT facility side A. Values are:
NORMAL (Available)
LOS (Loss of signal)
LOF (Loss of framing)
AIS (Alarm indication signal)
BER (Excessive bit errors)
FACBSTATUS Status of NT facility side B. Values are the same as for
FACASTATUS.
MEMASTATUS Status of system memory, side A. Values are:
NORMAL (Memory is OK)
FAULT (Memory is not OK)
MEMBSTATUS Status of system memory, side B. Values are the same
as for MEMASTATUS.
MEMMIGR Memory migration status (see DLT�MEM and
RST�MEM). Values are:
IDLE (Migration not possible)
BUSY (Migration in progress)
COMPLETE (Migration completed, rollback possible)
4 Miscellaneous System Commands
107 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
op_ne,value (cont) MEMSYNC Memory synchronization between sides A and B.
Values are:
INSYNC (Both sides synchronized)
OUTSYNC (Both sides not synchronized)
BUSY (Synchronization in progress)
NTASTATUS Status of NT side A. Values are:
NORMAL (Available)
UNAVAIL (Not present)
UNREACH (Cannot communicate with unit)
NTBSTATUS Status of NT side B. Values are the same as for
NTASTATUS.
NUMPROTNSW Rolling count of protection switching events
PROTCURR Current protection switching mode. Values are:
INH (Administratively inhibited)
ALW (Allowed)
SWA (Manually switched to side A)
SWB (Manually switched to side B)
SWCAUSE Reason for last protection switch. Values are:
NOSW (No switch has occurred)
MANSW (Manual/administrative switch)
EQPTF (Equipment failure or removal switch)
EXTCHF (Extender chain failure switch)
LNKF (Link (NT facility) failure switch)
TMOUT (watchdog timer timed out switch)
MEMf (database corruption caused switch)
MISMATCH (mismatch of board type or SW variant)
Example
Related Commands
4 Miscellaneous System Commands
108 / 166 3EC 36876 AEAA TCZZA Edition 02
Report system operational parameters.
REPT-OPSTAT-NE:RALGH:COM:42;
RALGH 00-11-24 12:30:43M 42 COMPLD /* REPT-OPSTAT-NE:RALGH:COM:42 */ “COM:ACTCHN,CHAINA” “COM:EQPTPRAC,LAUS “COM:EXTCHALEN,1” “COM:EXTCHBLEN,2” “COM:FACASTATUS,NORMAL” “COM:FACBSTATUS,NORMAL “COM:MEMASTATUS,NORMAL “COM:MEMBSTATUS,NORMAL” “COM:MEMMIGR,COMPLETE “COM:MEMSYNC,INSYNC” “COM:NTASTATUS,NORMAL” “COM:NTBSTATUS,NORMAL “COM:NUMPROTNSW,0” “COM:PROTCURR,ALW” “COM:SWCAUSE,NOSW”
DLT�MEM
RST�MEM
Function
Restrictions
Command Format
4 Miscellaneous System Commands
109 / 1663EC 36876 AEAA TCZZA Edition 02
4.9 RESV�NEXT�PORT
Reserves the first available port of a particular type for a user. If a
free port is found, it is assigned; otherwise, an error is reported.
Note User ports can be assigned to a user/customer, or be
free (available) for assignment. Assignment is based on
the value of the PORTID parameter associated with the
PORT. A specific port may be assigned using the
ED�(ADSL/SHDSL) commands, or any free (available)
port may be requested using the RESC�NEXT�PORT
command. Assigned ports may be freed (un�assigned)
using the FREE�PORT command.
All parameters in this command are position-defined. Port
assignment is independent of the state (faulty or otherwise) and
presence of connections on the port. You must verify the condition
of the port before reserving it.
RESV-NEXT-PORT:[tid]:port_type:[ctag]::port_id;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
port_type Type of port to be assigned. Valid values are:
ADSL ADSL port
SHDSL SHDSL port
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
port_id Label used to mark the port as assigned to a particular user (1...32 characters).
The following values are reserved and cannot be used:
AVAILABLE Port is not assigned
FAULTY Port is faulty and cannot be assigned
Response Format
4 Miscellaneous System Commands
110 / 166 3EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RESV-NEXT-PORT:[tid]:port-type:[ctag]::port_id */ port_type:port_aid;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RESV-NEXT-PORT:[tid]:port-type:[ctag]::port_id */ aid:ERRCDE=errcde /* error description */;
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (1...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
port_type As described for command parameters
port_aid Access identifier for the port. Values are:
ADSL�rack�shelf�lt_slot�circuit
LTSHDSL�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4, for ADSL, 1...3 for SHDSL)
lt_slot LT slot number (1...16)
circuit Circuit number (1...24)
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Example
Related Commands
4 Miscellaneous System Commands
111 / 1663EC 36876 AEAA TCZZA Edition 02
Free port ADSL�1�3�8�2.
RESV-NEXT-PORT:RALGH:ADSL:40::ARTURO;
RALGH 00-01-24 12:30:43M 40 COMPLD /* RESV-NEXT-PORT:RALGH:ADSL:40::ARTURO */ ADSL:ADSL-1-3-8-2;
ED�ADSL
ED�T1
FREE�PORT
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
112 / 166 3EC 36876 AEAA TCZZA Edition 02
4.10 RST�MEM
Restores the NE provisioning database to the backup version, if
one exists.
Note A backup database is saved during NE software
migration. It can be deleted with DLT�MEM.
All parameters in this command are position�defined.
RST–MEM:[tid]:aid_com:[ctag][:];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. Alcatel factory default value is null. The NE SID
code is the only other valid value.
aid_com Access Identifier for all common equipment. The value is COM.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Normal Response
tid yy-mm-dd hh:mm:ssM c COMPLD /* RST–MEM:[tid]:aid_com:[ctag][:] */;
Error Response
tid yy-mm-dd hh:mm:ssM c DENY /* RST–MEM:[tid]:aid_com:[ctag][:] */ aid:ERRCDE=errcde /* error description */;
Example
Related Command
4 Miscellaneous System Commands
113 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (2 digits), month, and day
hh:mm:ss Hour (00...23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
aid_com As described for command parameters
Restore the NE provisioning database to the backup version
created during the last NE software migration.
RST-MEM:RALGH:COM:42;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RST-MEM:RALGH:COM:42 */
DLT�MEM
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
114 / 166 3EC 36876 AEAA TCZZA Edition 02
4.11 RTRV�CMDSSN
Retrieves information about active Command Sessions.
All parameters in this command are position�defined.
At this moment only two Command Session owners are
supported:
� 5523 AWS: ADSL workstation (or another SNMP manager)
� Craft: craft interface.
Note: The CRAFT session is shared by all TL1 managers
including Local & Remote Craft Interfaces, as well as the TL1
Operations System.
Only one manager at a time can have a Command Session open.
The Craft Interface can have multiple nested Command sessions.
Command Sessions left idle for more than one minute are
automatically terminated. In case of a Craft Session, activity by
any TL1 manager keeps all Craft sessions active.
RTRV-CMDSSN:[tid]:aid_com:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_com Access identifier for all common equipment. The value is COM.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-CMDSSN:[tid]:aid_com:[ctag][:] */ aid_com:cmdssn_owner;
Example
Related Commands
4 Miscellaneous System Commands
115 / 1663EC 36876 AEAA TCZZA Edition 02
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-CMDSSN:[tid]:aid_com:[ctag][:] */ errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (1...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_com As described for command syntax
cmdssn_owner Owner of the Command Session. Valid values are:
AWS ADSL workstation (or another SNMP Manager)
CRAFT TL1 Manager (Local Craft, Remote Craft, or TL1 OS)
Retrieve information about active Command Sessions.
RTRV-CMDSSN:RALGH:COM:42;
RALGH 99-01-24 12:30:43M 42 COMPLD /* RTRV-CMDSSN:RALGH:COM:42 */ COM:AWS COM:CRAFT;
RTRV�CMDSSN
STA�CMDSSN
STP�CMDSSN
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
116 / 166 3EC 36876 AEAA TCZZA Edition 02
4.12 RTRV�HDR
Retrieves the NE header information.
All parameters in this command are position�defined.
RTRV-HDR:[tid]::[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-HDR:[tid]::[ctag][:] */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-HDR:[tid]::[ctag][:] */ errcde;
Example
Related Commands
4 Miscellaneous System Commands
117 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Retrieve header information for the RALGH NE.
RTRV-HDR:RALGH::42;
RALGH 98-11-24 12:30:43M 42 COMPLD /* RTRV-HDR:RALGH::42 */;
None.
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
118 / 166 3EC 36876 AEAA TCZZA Edition 02
4.13 RTRV�LOG
Retrieves selected logs.
All parameters in this command are position�defined.
RTRV-LOG:[tid]::[ctag]::lognms;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
lognms Names of logs to be retrieved. The only supported value is SECURITY.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-LOG:[tid]::[ctag]::lognms */ “lognms” /* logdump */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-LOG:[tid]::[ctag]::lognms */ errcde;
Example
Related Command
4 Miscellaneous System Commands
119 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
lognms As described for command parameters
logdump Dump of log buffer
Retrieve the SECURITY log.
RTRV-LOG:RALGH::40::SECURITY;
RALGH 98-11-24 12:30:43M 40 COMPLD /* RTRV-LOG:RALGH::40::SECURITY */ (dump of log buffer);
INIT�LOG
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
120 / 166 3EC 36876 AEAA TCZZA Edition 02
4.14 RTRV�MEM
Retrieves the list of software image files available in the NE, along
with the software version associated with each file.
All parameters in this command are position�defined.
RTRV-MEM:[tid]:aid_com:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_com Access Identifier for all common equipment. The value is COM.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-MEM:[tid]:aid_com:[ctag][:] */ filename[,filename,...];
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-MEM:[tid]:aid_com:[ctag][:] */ errcde;
Example
Related Commands
4 Miscellaneous System Commands
121 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
filename Name of a software module
Retrieve the list of software image files for the RALGH NE.
RTRV-MEM:RALGH:COM:40;
RALGH 98-11-24 12:30:43M 40 COMPLD /* RTRV-MEM:RALGH:COM:40 */ (filename);
None
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
122 / 166 3EC 36876 AEAA TCZZA Edition 02
4.15 RTRV�NE�ALL
Retrieves common provisioning data associated with the NE.
All parameters in this command are position�defined.
RTRV-NE-ALL:[tid]:[aid_com]:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
[aid_com] Access Identifier for all common equipment. The value is COM.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-NE-ALL:[tid]:[aid_com]:[ctag][:] */ aid_com:ne_nblk;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-NE-ALL:[tid]:[aid_com]:[ctag][:] */ errcde;
4 Miscellaneous System Commands
123 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
aid_com As described for command parameters
ne_nblk NE named parameter block containing one or more of the following parameters
(separated by commas):
APSSOAKINT The soaking period for activation of Automatic
protection switching (APS) in 1/100 seconds
(0..4294967295). 0 implies no soaking period
BOOTPVCI ATM VCI of the PVC over which the NE issues BOOTP
requests (32...65535)
BOOTPVPI ATM VPI of the PVC over which the NE issues BOOTP
requests (0...4000). Default is 0.
CMDSSNTMO Timeout for an idle command session (see
STA�CMDSSN or STP�CMDSSN), in seconds
(0...65535). A value of 0 disables the timeout feature.
DEFROUTER IP address of default IP router (if a router is used to
connect the AWS). Values are:
ddd.ddd.ddd.ddd (IP address, where ddd = 0...255)
NONE (No default IP router is used)
AWS must be used to configure SNTP.
EPSSOAKINT The soaking period for activation of equipment
protection switching (EPS) in 1/100 seconds
(0..4294967295).. 0 implies no soaking period
MEMALM Status of alarm condition indicating loss or corruption
of persistent memory. Values are:
ACTIVE (Persistent memory lost or corrupted)
CLEAR (Persistent memory OK)
After a loss or corruption of persistent memory is cor�
rected, the alarm condition must be manually cleared
using the MEMALM=CLEAR parameter of the SET�NE�
ALL command.
4 Miscellaneous System Commands
124 / 166 3EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
ne_nblk (cont) MEMDNLD Whether external download of system persistent
database is enabled. External download is typically
used to restore the database from a previous backup
version (see INIT�SYS). Values are:
ENABLED (Download is allowed)
DISABLED (Download is not allowed)
MEMSYNC Persistent memory synchronization in protection mode.
Values are:
DISABLED�(Memory synchronization is disabled)
ENABLED�(Memory synchronization is enabled)
NETPOS Position of the NE in the access subnetwork. Valid
values are:
HUB (NE is directly connected to the network)
SUBTENDING (NE is subtending from another ASAM.
No VC�level connections are allowed for a subtending
NE.)
Note: This parameter is not used and is available only
for backward compatibility. It will be removed in a fu�
ture release.
POTSTSTDUR Duration of the ADSL facility POTS test in minutes
(0...60). See STA�TST�ADSL command.
SNTP Use of Simple Network Time Protocol to maintain NE
clock. Values are:
ENABLED (Use SNTP)
DISABLED (Use NE local time set by SET�DAT com�
mand)
TZOFFSET Offset of local time zone from GMT/UTC, in minutes
(�780...780). Used by the system if SMTP=ENABLED.
Example
Related Commands
4 Miscellaneous System Commands
125 / 1663EC 36876 AEAA TCZZA Edition 02
Retrieve the common provisioning data associated with the
RALGH NE.
RTRV-NE-ALL:RALGH:COM:40;
RALGH 00-11-24 12:30:43M 40 COMPLD /* RTRV-NE-ALL:RALGH:COM:40 */ COM:BOOTPVPI=0,BOOTPVCI=32;
INIT�SYS
SET�DAT
SET�NE�ALL
STA�CMDSSN
STP�CMDSSN
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
126 / 166 3EC 36876 AEAA TCZZA Edition 02
4.16 RTRV�PORT
Retrieves a port in the NE, based on the optional Port Identifier
label associated with the port.
All parameters in this command are position�defined. If the Port
Identifier is not unique, the first port that matches the specified
value is returned.
RTRV-PORT:[tid]:[port_type]:[ctag]::port_id;
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
[port_type] Type of port to be retrieved. The only valid value is ALL.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
port_id Port Identifier label (1...32 characters) associated with the port to be retrieved.
The label is assigned with the RESV�NEXT�PORT command or the PORTID
parameter of the ED�ADSL and ED�SHDSL commands.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-PORT:[tid]:[port_type]:[ctag]::port_id */ port_type:port_aid;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY; /* RTRV-PORT:[tid]:[port_type]:[ctag]::port_id */ errcde;
Example
Related Commands
4 Miscellaneous System Commands
127 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (two digits), month, and day
hh:mm:ss Hour (00�23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
port_type Type of port. Values are:
ADSL ADSL port
SHDSL SHDSL port
port_aid AID of the user port. Values are:
ADSL�rack�shelf�slot�circuit
LTSHDSL�rack�shelf�lt_slot�circuit
rack Rack number (1...6)
shelf Shelf number (1...4 for ADSL; 1...3 for SHDSL)
lt_slot LT slot number (1...16)
circuit Circuit number (1...24)
Retrieve the first port associated with user HARRINGTON.
RTRV-PORT:RALGH:ALL:42::HARRINGTON;
RALGH 00-11-24 12:30:43M 42 COMPLD /* RTRV-PORT:RALGH:ALL:42::HARRINGTON */ ADSL:ADSL-3-2-7-1;
ED�ADSL
ED�T1
RESV�NEXT�PORT
Function
Restrictions
Command Format
Response Format
4 Miscellaneous System Commands
128 / 166 3EC 36876 AEAA TCZZA Edition 02
4.17 RTRV�SYNCN
Retrieves the configuration of the reference source to be used for
synchronization of the NE clock.
All parameters in this command are position�defined.
RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:];
Command Parameters
Parameter Explanation
[tid] Identification of the target NE. TID is optional and has an Alcatel factory default
value of null. The NEs SID code is the only other valid value.
[aid_syncn] AID of the NE clock. The value is CLKSRCNT.
[ctag] Correlation tag (1...6 characters) that links an input command with associated
output responses. The default is 0.
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ aid_syncn::[syncn_nblk];
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* RTRV-SYNCN:[tid]:[aid_syncn]:[ctag][:] */ errcde;
Example
Related Commands
4 Miscellaneous System Commands
129 / 1663EC 36876 AEAA TCZZA Edition 02
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (two digits), month, and day
hh:mm:ss Hour (00�23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (see Appendix B)
[aid_syncn] As described for command parameters
syncn_nblk Clock synchronization parameter block. The block consists of the following
parameter, followed by an equal sign and a value.
PRICREF Primary reference source for synchronizing the clock.
Values are:
LOOP (Loop timing recovered from network side facili�
ty)
LOCAL (Local oscillator on NT board)
REDNT (Local oscillator on redundant NT board)
Retrieve the configuration of the reference source for
synchronization of the NE clock.
RTRV-SYNCN:RALGH:CLKSRCNT:42;
RALGH 99-11-24 12:30:43M 42 COMPLD /* RTRV-SYNCN:RALGH:CLKSRCNT:42 */ CLKSRCNT::PRICREF=LOCAL;
DLT�SYNCN
ED�SYNCN
ENT�SYNCN
Function
Restrictions
Command Format
4 Miscellaneous System Commands
130 / 166 3EC 36876 AEAA TCZZA Edition 02
4.18 SET�DAT
Sets the date and time in the NE.
All parameters in this command are position�defined.
Resetting the NT or the ASAM also resets the date and time.
SET-DAT:[tid]::[ctag]::date,time;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NE's SID code is the only other valid value.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
date Date in the following format:
mm�dd�yy Month, day, and year
mm Month (1...12)
dd Day (1...31)
yy Year (00...99)
Note: Following interpretation is used for yy:
00..69 --> 2000...2069
70..99 --> 1970...1999
Current implementation restricts dates between 1970
and 2035.
time Time in the following format:
hh�mm�ss Hour, minute, and second
hh Hour (00...23)
mm Minute (00...59)
ss Second (00...59)
Response Format
Example
Related Command
4 Miscellaneous System Commands
131 / 1663EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-DAT:[tid]::[ctag]::date,time */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* SET-DAT:[tid]::[ctag]::date,time */; errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Set the date to 20 December 2000 and the time to 11:23:45 in
the RALGH NE.
SET-DAT:RALGH::42::12-20-00,11-23-45;
RALGH 00-12-20 11:23:45M 42 COMPLD /* SET-DAT:RALGH::42::12-20-00,11-23-45 */;
None.
Function
Restrictions
Command Format
4 Miscellaneous System Commands
132 / 166 3EC 36876 AEAA TCZZA Edition 02
4.19 SET�NE�ALL
Sets miscellaneous provisioning parameters in an NE.
All parameters in this command are position�defined.
SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NE's SID code is the only other valid value.
[aid_com] Access Identifier for all common equipment. The value is COM.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
ne_nblk NE named parameter block containing one or more of the following parameters
(separated by commas):
BOOTPVPI ATM VPI of the PVC over which the NE issues BOOTP
requests (0...4000). The default is 0.
BOOTPVCI ATM VCI of the PVC over which the NE issues BOOTP
requests (32...65535). The default is 32.
CMDSSNTMO Timeout for an idle command session (see
STA�CMDSSN or STP�CMDSSN), in seconds
(0...65535). A value of 0 disables the timeout feature.
DEFROUTER IP address of default IP router (if a router is used to
connect the AWS). Values are:
ddd.ddd.ddd.ddd (IP address, where ddd =
1...255)
NONE (No default IP router is used)
MEMALM Used to clear an alarm condition indicating loss or
corruption of persistent memory (see RTRV�NE�ALL).
Valid values are:
CLEAR (persistent memory OK)
ACTIVE (persistent memory lost/corrupted
Note: An active alarm must be cleared after restoring
memory.
MEMDNLD Whether external download of system persistent
database is enabled (see RTRV�NE�ALL). The only valid
value is ENABLED.
4 Miscellaneous System Commands
133 / 1663EC 36876 AEAA TCZZA Edition 02
Parameter Explanation
ne_nblk (cont) NETPOS Position of the NE in the access subnetwork. Valid
values are:
HUB (NE is directly connected to the network)
SUBTENDING (NE is subtending from another ASAM.
No VC�level connections are allowed for a subtending
NE.)
Note: This parameter is not used and is available only
for backward compatibility. It will be removed in a fu�
ture release.
POTSTSTDUR Duration of the ADSL facility POTS test in minutes
(0...60). See STA�TST�ADSL command.
SNTP Use of Simple Network Time Protocol to maintain NE
clock. Values are:
ENABLED (Use SNTP)
DISABLED (Do not use SNTP; use NE local time set by
SET�DAT command)
AWS must be used to configure SNTP.
TZOFFSET Offset of local time zone from GMT/UTC, in minutes
(�780...780). Used by the system if SMTP=ENABLED.
APSSOAKINT The soaking period for activation of Automatic
protection switching (APS) in 1/100 seconds
(0..4294967295). 0 implies no soaking period
EPSSOAKINT The soaking period for activation of equipment
protection switching (EPS) in 1/100 seconds
(0..4294967295). 0 implies no soaking period
MEMSYNC Persistent memory synchronization in protection mode.
Values are:
DISABLED�(Memory synchronization is disabled)
ENABLED�(Memory synchronization is enabled)
Only parameters specified in the Ne_nblk will be changed. Other parameters re�
main unchanged
Response Format
Example
Related Commands
4 Miscellaneous System Commands
134 / 166 3EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk */ errcde;
Response Parameters
Parameter Explanation
sid Source NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Set the common provisioning parameters for the RALGH NE.
SET-NE-ALL:RALGH:COM:40:::BOOTPVPI=4003,BOOTPVCI=29730;
RALGH 00-11-24 12:30:43M 40 COMPLD /* SET-NE-ALL:RALGH:COM:40:::BOOTPVPI=4003,BOOTPVCI=29730 */;
RTRV�NE�ALL
SET�DAT
STA�TST�ADSL
STP�TST�ADSL
Function
Restrictions
Command Format
4 Miscellaneous System Commands
135 / 1663EC 36876 AEAA TCZZA Edition 02
4.20 SET�SID
Sets the system identifier (SID) of the NE. The SID is used to
uniquely identify an NE in the system, so the SID must be unique
for each NE.
All parameters in this command are position�defined.
The SID is used to uniquely identify an NE in the system, so the
SID must be unique for each NE.
SET-SID:[tid]::[ctag]::sid;
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NE's SID code is the only other valid value.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
sid System identifier (SID). A text string of up to 20 characters containing only letters,
digits or hyphens. It is recommended to use the NEs CCLI code as the SID.
Note: The SID is case�sensitive.
Response Format
Example
Related Commands
4 Miscellaneous System Commands
136 / 166 3EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* SET-SID:[tid]::[ctag]::sid */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* SET-SID:[tid]::[ctag]::sid */; errcde;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (00...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
errcde Error code (See Appendix B)
Set the SID for the RALGH NE to �RALEIGH�NC".
SET-SID:RALGH::42::RALEIGH-NC;
RALGH 98-12-20 11:23:45M 42 COMPLD /* SET-SID:RALGH::42::RALEIGH-NC */;
None.
Function
Restrictions
Command Format
4 Miscellaneous System Commands
137 / 1663EC 36876 AEAA TCZZA Edition 02
4.21 STA�CMDSSN
Initiates a Command Session on behalf of the issuing manager.
While a Command Session is in progress, only the owner of the
session can modify the NE database.
At this moment only two Command Session owners are
supported:
� 5523 AWS: ADSL workstation (or another SNMP manager)
� Craft: craft interface.
Note: The CRAFT session is shared by all TL1 managers
including Local & Remote Craft Interfaces, as well as the TL1
Operations System.
Only one Manager can have an active Command Session at one
time. The Craft Interface can have multiple nested Command
Sessions. Command Sessions left idle for more than one minute
are automatically terminated. Activity by any TL1 manager keeps
all Craft Command Sessions active.
STA-CMDSSN:[tid]:aid_com:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NEs SID code is the only other valid value.
aid_com Access identifier for all common equipment. The value is COM.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Response Format
Example
Related Commands
4 Miscellaneous System Commands
138 / 166 3EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* STA-CMDSSN:[tid]:aid_com:[ctag][:]; */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* STA-CMDSSN:[tid]:aid_com:[ctag][:]; */ aid_com:ERRCDE=errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (1...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
aid_com As described for command parameters
errcde Error code (See Appendix B)
Initiate a Command Session.
STA-CMDSSN:RALGH:COM:42;
RALGH 99-01-24 12:30:43M 42 COMPLD /* STA-CMDSSN:RALGH:COM:42 */;
RTRV�CMDSSN
STP�CMDSSN
Function
Restrictions
Command Format
4 Miscellaneous System Commands
139 / 1663EC 36876 AEAA TCZZA Edition 02
4.22 STP�CMDSSN
Terminates any active 'Command Session' owned by the issuing
manager.
All TL1 managers share ownership of their Command Sessions, so
care should be exercised when issuing this command.
At this moment only two Command Session owners are
supported:
� 5523 AWS: ADSL workstation (or another SNMP manager)
� Craft: craft interface.
Note: The CRAFT session is shared by all TL1 managers
including Local & Remote Craft Interfaces, as well as the TL1
Operations System.
Only one manager at a time can have an active Command
Session. The Craft Interface can have multiple nested Command
Sessions. Command Sessions left idle for more than one minute
are automatically terminated. Activity by any TL1 manager keeps
all Craft Command sessions alive.
STP-CMDSSN:[tid]:aid_com:[ctag][:];
Command Parameters
Parameter Explanation
[tid] The identification of the target NE. TID is optional and has an Alcatel factory
default value of null. The NE's SID code is the only other valid value.
aid_com Access identifier for all common equipment. The value is COM.
[ctag] The correlation tag that correlates an input command with its associated output
response(s). It is assigned by the originator of the command. The value is limited
to six characters, which may be an identifier or a decimal numeral. It is optional
with a default of 0.
Response Format
Example
Related Commands
4 Miscellaneous System Commands
140 / 166 3EC 36876 AEAA TCZZA Edition 02
Normal Response
sid yy-mm-dd hh:mm:ssM c COMPLD /* STP-CMDSSN:[tid]:aid_com:[ctag][:]; */;
Error Response
sid yy-mm-dd hh:mm:ssM c DENY /* STP-CMDSSN:[tid]:aid_com:[ctag][:]; */ aid_com:ERRCDE=errcde /* error description */;
Response Parameters
Parameter Explanation
tid Target NE identification
yy�mm�dd Year (last two digits), month, and day
hh:mm:ss Hour (1...24), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments � unspecified format
aid_com As described for command parameters
errcde Error code (See Appendix B)
Terminate any active Command Sessions.
STP-CMDSSN:RALGH:COM:42;
RALGH 99-01-24 12:30:43M 42 COMPLD /* STP-CMDSSN:RALGH:COM:42 */;
RTRV�CMDSSN
STA�CMDSSN
Default NotificationCode (NTFCNCDE)
Appendix A Alarms and Events
141 / 1663EC 36876 AEAA TCZZA Edition 02
Appendix A Alarms and Events
A.1 General Description
This appendix provides tables that summarize the provisionable
and non�provisionable characteristics of the condition types used
by the ASAM. Condition types help you to isolate the type of error
to minimize the time taken to clear delays. These tables should be
useful after initial provisioning. (Refer to the Task Oriented
Procedures manual for complete provisioning instructions.)
When errors are detected by the system, you are notified by either:
� Retrieving current alarm conditions using TL1 commands or
� Receiving automatically generated system status and event
reporting through autonomous messages.
A.2 Retrieving Current Status of Alarms and Conditions
Provisionable alarm conditions have associated notification codes
with varying degrees of severity. Although these alarms have
default notification codes, most codes can be changed using the
set attribute (SET�ATTR�<xxx>) TL1 commands, where <xxx>
represents the entity associated with the alarm condition. When
the notification codes are set, the current alarm conditions can be
retrieved at any time using the retrieve alarm (RTRV�ALM�<xxx>)
and retrieve condition (RTRV�COND�<xxx>) TL1 commands for
an entity. The standard alarm notification codes are:
CR Critical alarm
MJ Major alarm
MN Minor alarm
A.3 Table Description
The tables in this appendix are organized by entities that are valid
for the ASAM. Each condition type is listed with the default
notification code values, service�affecting/non�service�affecting
behavior codes, and brief descriptions.
In the following tables, the default notification code column lists
the default alarm notification codes for the equipment or facility.
Most notification codes can be changed by the SET�ATTR TL1
command for that entity.
Service�affecting/Non�service�affecting
Behaviour
Appendix A Alarms and Events
142 / 166 3EC 36876 AEAA TCZZA Edition 02
If the notification code is Critical, Major, or Minor, an alarm
autonomous message (REPT�ALM) reports changes in the alarm
condition for in service (IS) entities. If the entity is out�of�service
(OOS�MA), reporting is suppressed. The RTRV�ALM or
RTRV�COND commands are used to retrieve the current state of
the alarm.
Service�affecting behavior is listed as either service�affecting (SA)
or non�service�affecting (NSA).
ADSL Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁFACTERM
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMajor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁModem could not initializeÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LCD�I*
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of cell delineation, interleaved
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LCD�F* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of cell delineation, fast
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOF ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of frame
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOL ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of link
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of signal
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LPRÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of power
CFGERR SA Critical Modem activation failed�config error
COMMF SA Major Unable to communicate w/ peer modem
CAPINSUF SA Major Line capacity insufficient to meet config
NOPEER SA Minor No peer modem detected
LORATE SA Minor Line rate is below planned rate
CELLDSCUP* SA Minor Upstream cell discard
CELLDSCDN* SA Minor Downstream cell discard
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
*ATM alarms reported via the ADSL facility
Appendix A Alarms and Events
143 / 1663EC 36876 AEAA TCZZA Edition 02
Common Equipment / NE (COM) Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
INIT SA Critical System ans backup memory reset
IQCLKOOL SA Critical IQ-bus clock not locked to reference
IQREFCLK SA Critical IQ-bus reference clock lost
SNTPCOM NSA Major Unable to communicate w/ SNTP server
SWCAP NSA Major Loss of protection switching
DISKSPACE NSA Major Disk is 90% full
E1 Facility Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ACTLPBK ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁFacility placed in loopback
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
AIS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁAlarm indication signal
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
FAULT�IMA**ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IMA link fault
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LCD*ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of ATM cell delineationÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLIF**
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of IMA frameÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LODS**
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IMA link out of delay synchronization
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MISMATCH ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁInterface does ot match configuration
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOF ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMajor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of framing
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of signal/clock
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MISCONN** ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA link misconnected
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RAIÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Remote alarm indication
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RFI�IMA**ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IMA remote failure indicationÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
UNUSABLE�IMA**ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IMA link unusable due to far�end
behavior
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
*ATM condition reported via the T1 facility (for E1s directly transporting ATM)
**IMA condition reported via the T1 facility (for E1s used as a link with IMA)
Appendix A Alarms and Events
144 / 166 3EC 36876 AEAA TCZZA Edition 02
Environment (ENV) Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMISC*
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁNSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁMiscellaneous environment alarmÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
*There are five miscellaneous alarms, corresponding to AIDs ENV�1 through ENV�5.
Equipment Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ATMHW ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ATM hardware error
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
BUSCFG ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Critical ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Backplane configuration error
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
COMMERRÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MajorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Failed to communicate with the module
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CONTBUSÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Subrack backplane faultÁÁÁÁÁÁÁÁÁÁÁÁÁÁCONTCOM
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁCritical
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSubrack extender bus faultÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁEQPT
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁEvent
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁEquipment insertedÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
FA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Fuse alarm (power fuse blown)
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
FANALM�1 ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Fan alarm for Fan�1
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
FANALM�2 ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Fan alarm for Fan�2
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
HITEMP ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Module temperature exceeded limit
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IMPROPRMVL ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Improper removal of provisioned module
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
INITÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
System and backup memory resetÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IQCLKOOLÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IQ�Bus clock not locked to referenceÁÁÁÁÁÁÁÁÁÁÁÁÁÁIQREFCLK
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁCritical
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁIQ�Bus reference clock lostÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MEMDIF
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Plug�in module does not match
configurationÁÁÁÁÁÁÁÁÁÁÁÁÁÁPROGVER
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁNSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMajor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁFailed to load or find requested softwareÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RMTDLFAIL
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Major
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Failed to download software
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SHUTDOWN ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Major ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Equipment shutdown due to high
temperatureÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SWROLLBK
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Software version rolled back
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
UNPLANNED ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Module inserted in slot planned for
NO�BOARD
MEMDIFEH NSA Minor Equipment holder config mismatch
DEFENCE SA Critical Equipment shutdown�defense action
EQUIP - Event Module inserted
UNEQUIP - Event Module removed
Appendix A Alarms and Events
145 / 1663EC 36876 AEAA TCZZA Edition 02
IMA Group Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
BLOCKED ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁGroup operation inhibited
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CFGABORT ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Remote configuration request not
supported
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
INSUFLNKS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Insufficient number of IMA links to
operate
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
STARTUP ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁRemote IMA group start�up
IMA Link Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLIF *
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of IMA Frame.ÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LODS *
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IMA Link out of Dealy Sunchronization
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MISCONN* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA Link misconnected
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RFI�IMA* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA Remote failure indication
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
FAULT�IMA* ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁIMA link fault
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
UNUSABLE�IMA*ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
IMA Link unusable due to Far�end
behavior
*IMA Link related conditions are reported via the associated facilty
(e.g. E1/T1/SHDSL). However their attributes can only be
provisioned using the SET/RTRV�ATTR�IMALNK commands.
Appendix A Alarms and Events
146 / 166 3EC 36876 AEAA TCZZA Edition 02
SHDSL Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOSW-NS�1
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of sync word - Network Side �
Loop1ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOSW-NS�2ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of sync word - Network Side �
Loop2
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOSW-CS�1ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of sync word - Customer Side �
Loop1
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOSW-CS�2ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of sync word - Customer Side �
Loop2
ATEN�NS�1 SA Minor Loop attenuation alarm - Network Side �
Loop1
ATEN�NS�2 SA Minor Loop attenuation alarm - Network Side �
Loop2
ATEN�CS�1 SA Minor Loop attenuation alarm - Customer Side
� Loop1
ATEN�CS�2 SA Minor Loop attenuation alarm - Customer Side
� Loop2
SNR�NS�1 SA Minor Signal to noise ratio alarm - Network
Side � Loop1
SNR�NS�2 SA Minor Signal to noise ratio alarm - Network
Side � Loop2
SNR�CS�1 SA Minor Signal to noise ratio alarm - Customer
Side � Loop1
SNR�CS�2 SA Minor Signal to noise ratio alarm - Customer
Side � Loop2
DCCONT�NS�1 SA Minor DC continuity fault - Network Side �
Loop1
DCCONT�NS�2 SA Minor DC continuity fault - Network Side �
Loop2
DCCONT�CS�1 SA Minor DC continuity fault - Customer Side �
Loop1
DCCONT�CS�2 SA Minor DC continuity fault - Customer Side �
Loop2
ACTLPBK�NS SA Minor Facility placed in loopback - Network
Side
Appendix A Alarms and Events
147 / 1663EC 36876 AEAA TCZZA Edition 02
CONDITION DESCRIPTION
DEFAULT
NTFCNCDE
SERVICE
AFFECTING?
CONFERR SA Minor Configuration error
LCD SA Minor Loss of ATM Cell Delineation (see Note)
LPR SA Minor Loss of power at STU�R
SECUERR SA Minor Unable to disable STU�R access
DEVFAIL SA Minor Device Failure
Note These ATM alarms are only supported for STU�C and
STU�R.
E3 Facility Conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RAI ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMAJOR ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁRemote Alarm Indication
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
AIS ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁCritical ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁAlarm Indication Signal
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOF ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁCritical ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of framing
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOSÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
CriticalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of Signal/Clock
LCD* SA Critical Loss of cell delineation
ACTLPBK SA Critical Network side in loopback
PLM�P SA Minor Payload type mismatch
PLU SA Minor Stable payload type
UNEQ-P SA Minor Payload unequipped
CELLSIG SA Critical False start�of�cell input signal
OVRFLO SA Critical Buffer (FIFO) overflow
UDRFLO SA Critical Buffer (FIFO) underflow
* These ATM conditions are reported via the E3 facility
Appendix A Alarms and Events
148 / 166 3EC 36876 AEAA TCZZA Edition 02
OC3 facility condition
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁAIS�L
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLine alarm indication signalÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
BERL�HT
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Critical
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Excessive line bit errors
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RFI�L ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Remote failure/defect indication
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
T�CV�LFE ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Excessive far�end block errors
T�CV�S SA Critical Excessive section BIP�8 errors
LOF SA Critical Section loss of frame
LOS SA Critical Section loss of signal
LOC SA Critical Section loss of clock
CELLSIG SA Critical False start�of�cell input signal
OVRFLO SA Critical Buffer (FIFO) overflow
REFCLK SA Critical Reference clock failed
FIFOCLK SA Critical FIFO clock failed
LCD* SA Critical Loss of ATM cell delineation
* These ATM conditions are reported via the OC3 facility
STS3C facility conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁPLM�P
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁNSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁMinor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁSignal Label MismatchÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
PLU
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Signal Label Unstable
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
UNEQ�P ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Path Unequipped
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RFI�P ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Minor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Remote Path Failure/Defect Indication
T�CV�P SA Major Excessive Path BIP errors
T�CV�PFE SA Minor Excessive Path Far-End Block Errors
LOP SA Critical STS Loss of Pointer
AIS�P SA Minor Path Alarm Indication Signal
Appendix A Alarms and Events
149 / 1663EC 36876 AEAA TCZZA Edition 02
Signaling channel conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ANISIGCHN�
FAILURE
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Critical
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Failure of network-side Signaling
ChannelÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
UNISIGCHN�
FAILURE
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
SAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Failure of user-side Signaling Channel
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
T1-SIGSYS1-PERFÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Performance count threshold exceeded on
Signaling Channel
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
T1-SIGSYS1-SUMÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Performance summary count threshold
exceeded on Signaling Channel
Signaling subsystem conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
T1-SIGSYS1-PERFÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
NSAÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Performance count threshold exceeded for
Signaling Subsystem
T3 (DS3) facility conditions
CONDITION
SERVICE
AFFECTING?
DEFAULT
NTFCNCDE DESCRIPTION
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
RAI ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA ÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁMinor ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁRemote alarm indication
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
AISÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MinorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Alarm indication signalÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
LOFÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MajorÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Loss of framingÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLOS
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁSA
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁCritical
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁLoss of signal/clock
ATMFE SA Major ATM DS3 PLCP Far-End Alarm
ATMLOF SA Major ATM DS3 PLCP Loss of Frame
LCD SA Critical Loss of ATM Cell Delineation
Appendix A Alarms and Events
150 / 166 3EC 36876 AEAA TCZZA Edition 02
Appendix B Error Codes
151 / 1663EC 36876 AEAA TCZZA Edition 02
Appendix B Error Codes
An error code is a four�character mnemonic in the response to an
input command that describes why the command cannot be
executed. The error codes are grouped into categories of
� equipage (E)
� input (I)
� multiple error (M)
� privilege (P) and
� status (S).
The following table lists the error codes, their descriptions, and the
Technical Advisory (TA) or Technical Reference (TR) from which the
error codes originate.
ASAM Error Code Summary
CODE DESCRIPTION TA/TR
ENDS Equipage, not equipped with duplex switching TA�200
EQWT Equipage, wrong type TA�200
ICNC Input, command not consistent TA�200
IDNC Input, data not consistent TA�200
IDNV Input, data not valid TA�200
IEAE Input, entity already exists TA�200
IENE Input, entity not exists (does not exist) TA�200
IISP Input, invalid syntax or punctuation TA�200
IITA Input, invalid target identifier - the command contains an invalid TID TA�200
IPEX Invalid extra input parameter TA�200
IPMS Input parameter missing TA�200
IPNC Input parameter not consistent TA�200
IPNV Input parameter not valid TA�200
SAAL Status, already allowed TA�200
SAIN Status, already inhibited TA�200
SARB Status, all system resources busy TA�200
SDNA Status, duplex unit not available TA�200
SDNC Status, data not consistent TA�200
SLEM Status, list exceed maximum - command processing exceeded system
limit
TA�200
Appendix B Error Codes
152 / 166 3EC 36876 AEAA TCZZA Edition 02
CODE TA/TRDESCRIPTION
SNVS Status, not in valid state TA�200
SRCI Status, requested command(s) inhibited TA�200
SROF Status, requested operation failed TA�200
SSRE Status, system resources exceeded - the command exceeded the
system limit on a parameter
TA�200
SSTP Status, command execution stopped - the command execution was
terminated because of a software/hardware problem
TA�200
Appendix C ATM Addressing
153 / 1663EC 36876 AEAA TCZZA Edition 02
Appendix C ATM Addressing
C.1 Introduction
This appendix describes the formats for ATM addresses used in
SVC commands. All four formats specified by the ATM Forum are
supported:
� Data Country Code ATM End System Address (AESA)
� Internation Code Designator AESA
� E.164 AESA
� Native E.164
Unformatted AESA addresses are also supported.
C.2 Data Country Code AESA Format
The format for DCC AESA addresses is:
DCC-idi.hodsp.esi.sel
idi Initial Domain Identifier (3 digit decimal).
The value is a 3�digit Country Code.
hodsp Higher�Order Domain�Specific Part (20
digit hexadecimal). If fewer than 20 digits
are specified, the value is padded with
trailing zeroes.
esi End System Identifier (12 digit
hexadecimal). If fewer than 12 digits are
specified, the value is padded with trailing
zeroes.
sel Selector (2 digit hexadecimal). If fewer than
2 digits are specified, the value is padded
with trailing zeroes.
Appendix C ATM Addressing
154 / 166 3EC 36876 AEAA TCZZA Edition 02
C.3 International Code Designator AESA Format
The format for ICD AESA addresses is:
ICD-idi.hodsp.esi.sel
idi Initial Domain Identifier (4 digit decimal).
The value is a 4�digit International Code
Designator that identifies an international
organization.
hodsp Higher�Order Domain�Specific Part (20
digit hexadecimal). If fewer than 20 digits
are specified, the value is padded with
trailing zeroes.
esi End System Identifier (12 digit
hexadecimal). If fewer than 12 digits are
specified, the value is padded with trailing
zeroes.
sel Selector (2 digit hexadecimal). If fewer than
2 digits are specified, the value is padded
with trailing zeroes.
C.4 E.164 AESA Format
The format for E.164 AESA addresses is:
AE164-idi.hodsp.esi.sel
idi Initial Domain Identifier (1...15 digit
decimal). The value is an E.164 telephone
number.
hodsp Higher�Order Domain�Specific Part (8 digit
hexadecimal). If fewer than 8 digits are
specified, the value is padded with trailing
zeroes.
esi End System Identifier (12 digit
hexadecimal). If fewer than 12 digits are
specified, the value is padded with trailing
zeroes.
sel Selector (2 digit hexadecimal). If fewer than
2 digits are specified, the value is padded
with trailing zeroes.
Appendix C ATM Addressing
155 / 1663EC 36876 AEAA TCZZA Edition 02
C.5 Native E.164 Format
The format for native E.164 addresses is:
AE164-phone
phone E.164 telephone number (1...15 digit
decimal)
C.6 Unformatted AESA Format
The format for unformatted AESA addresses is:
A-address
address AESA address exactly as it is represented
internally (1...15 digit hexadecimal)
Appendix C ATM Addressing
156 / 166 3EC 36876 AEAA TCZZA Edition 02
Appendix D System Access Identifiers
157 / 1663EC 36876 AEAA TCZZA Edition 02
Appendix D System Access Identifiers
This appendix provides information about the System AIDs It first
provides information about the equpment arrangements for:
� Standard Density (SD) systems
� High Density (HD) systems
� Ulta Density (UD) systems.
Then the document lists the Equipment AIDs.
D.1 Standard Density Systems
Figure 1 shows the equipment arrangement for the SD ASAM.
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
– – –
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
NTA
or
EXA
NTA
or
EXB
LT1 LT2LT12 ACU
ATU�R
ATU�R
ATU�R
ATU�R
Shelf Detail
ASAM (NE)
Rack�1 Rack�2 Rack�3 Rack�4
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Figure 1 Standard Density ASAM (NE) Equipment Arrangement
A SD ASAM can have a maximum of 4 racks. Each rack can have
up to 4 shelves.
Note The maximum number of shelves allowed in an ASAM
is 12
Appendix D System Access Identifiers
158 / 166 3EC 36876 AEAA TCZZA Edition 02
D.2 High�Density Systems
Figure 2 shows the equipment arrangement for the HD ASAM.
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
– – –
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
– – –
– – –
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
– – –TAU
or
TEU
LP1 LP2 LP1
6
ACU
NTA
or
EXA
NTA
or
EXBLT1 LT2 LT16
ATU�R
ATU�R
ATU�R
ATU�R
ATU�R
ATU�R
Shelf Detail
ASAM (NE)
Rack�1 Rack�2 Rack�3 Rack�4 Rack�5 Rack�6
Shelf
Shelf Shelf
ShelfShelf
Shelf Shelf
ShelfShelf
Shelf Shelf
Shelf
Figure 2 High Density ASAM (NE) Equipment Arrangement
An HD ASAM can have a maximum of 6 racks. Each rack can up
to 2 shelves.
Note The maximum number of shelves allowed in an ASAM
is 12
Appendix D System Access Identifiers
159 / 1663EC 36876 AEAA TCZZA Edition 02
D.3 Ultra�Density Systems
Figure shows the equipment arrangement for the UD ASAM.
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
– – –
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
– – –
– – –
Shelf Detail
ACU
NTA
or
EXA
NTA
or
EXBLT1 LT2 LT16
ATU�R
ATU�R
ATU�R
ATU�R
ATU�R
ATU�R
Rack�1 Rack�2 Rack�3
ASAM (NE)
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Shelf
Figure 3 Ultra Density ASAM (NE) Equipment Arrangement
An UD ASAM can have a maximum of 3 racks. Each rack can up
to 3 shelves.
Note The maximum number of shelves allowed in an ASAM
is 6 because of the limit on the number (2304) lines.
Racks (RACK)
Shelves (SHELF)
Network TerminationUnits (NT)
Server Units (SERV)
IP Gateway Server(IPGW)
Appendix D System Access Identifiers
160 / 166 3EC 36876 AEAA TCZZA Edition 02
D.4 Equipment Access Identifiers
This sections describes the equipment AIDs used in the A7300
ASAM.
The ASAM may have up to 6 racks. The AID for the racks is:
RACK�rack
where rack is the rack�number.
The ASAM may have up to 2 HD shelves (sub�racks), 3 UD or 4
SD shelves in a rack. The AID for shelves is:
SHELF�rack�shelf
where rack is the rack number and shelf is the shelf
number (1...4).
The NT are always located in the first shelf of the first rack in a
system (ASAM). The primary NT unit is the NTA, while the
secondary or backup unit is the NTB. The AIDs for the NT are:
{NT|NTA|NTB}
Server Units are special boards that use the LT slots in shelf 1 and
which support auxillary services in the ASAM. The AID for the
Server Units is:
SERV�rack�shelf�sv_slot
Note: Presently
Note Server units may only be placed in rack 1, shelf 1. In
this release the only server unit supported is the IP
Gateway type A (IPGWA).
The AID for IP Gateway (IPGW) server units is
IPGW�rack�shelf�sv_slot
Note Server units may only be placed in rack 1, shelf 1
The IPGW server is a two�slot card that must be
planned in a slot�pair.
Slots are paired as 1�2, 3�4, .., 15�16. The sv_slot
used must be the lower slot number in the pair (e.g.,
1 for 1�2, 3 for 3�4, .. 15 for 15�16).
Shelf Extender Units(EX)
Line Termination Units(LT)
Line TerminationApplique Units (LP)
Test Access Unit (TAU)and Test Extender Units
(TEU)
Alarm Control Unit(ACU)
Appendix D System Access Identifiers
161 / 1663EC 36876 AEAA TCZZA Edition 02
All subsequent shelves in the system are configured with Shelf
Extender (EX) units instead NTs. The extender units connect the
shelf to the previous one in daisy�chain fashion. The extender units
correspond to NT units in the first shelf and have primary unit �
EXA, and backup unit EXB. The AIDs for Shelf Extender units are:
{EX|EXA|EXB}�rack�shelf
Note rack=1, shelf=1 is not a valid AID for an Extender
since this location is only used for an NT.
Each shelf in the ASAM supports LT units in LT slots 1..12 for SD
shelves and slots 1..18 for HD shelves. The AIDs for the Line
Termination units are:
LT�rack�shelf�lt_slot
Each LT in the HD shelf is associated with a separate applique unit
that performs LT support functions. The AID for the LP units is:
LP�rack�shelf�lt_slot
Note LP Units are not managed in release 4.2.
The ASAM supports a single TAU for HD systems that is located in
the first system shelf (rack 1, shelf 1). This unit supports external
test access to circuits in the LT. The TAU connects to other shelves
via a daisy�chain connection using the TEUs located in the same
slot in all subsequent shelves in the system. The AIDs for the TAU
TEU are:
TAU
The TAU is always located in rack 1, shelf 1.
TEU�rack�shelf
The TEU is located in shelves other than rack 1, shelf 1.
Note The TAU and TEUs are not managed in release 4.2.
Each shelf has a slot for an ACU. However, only one ACU is
needed for each rack of an ASAM. ACUs may only be installed in
the first shelf of every rack except the first rack. In the first rack the
ACU must be in the same shelf as the NT. The AID is:
ACU�rack�shelf
ATU�R (ATUR)
ADSL Facilities (ADSL)
OC3 and STS3CFacilities
E1 Facilities
E3 Facilities
Appendix D System Access Identifiers
162 / 166 3EC 36876 AEAA TCZZA Edition 02
The ADSL Termination Unit � Remote (ATU�R ) or the ADSL modem
at the customer premises is managed in a limited way by the
ASAM. The ATU�R is identified by the ADSL circuit to which it is
connected via the LT. The AID is:
ATUR�rack�shelf�lt_slot�circuit
D.5 Transport Facility Access Identifiers
This section describes the AIDs associated with the transport
facility.
Each ADSL LT supports ADSL Termination Unit�Central (ATU�C)
modems. Each modem supports a single ADSL line or circuit. The
AID for ADSL lines is:
ADSL�rack�shelf�lt_slot�circuit
Note SD LTs support 4 circuits
HD LTs support 12 circuits
UD LTs support 24 circuits.
The SONET�NT units (NTA and NTB) and SONET�LT units support
corresponding OC3 and STS3C facilities. The AIDs for these
facilities are:
NT Facilities:
{NTOC3|NTOC3A|NTOC3B}
{NTSTS3C|NTSTS3CA|NTSTS3CB}
LT Facilities:
LTOC3�rack�shelf�lt_slot�circuit
LTSTS3C�rack�shelf�lt_slot�circuit
The E1�NT units support corresponding E1 facilities. The AIDs for
the NT E1 facilities are:
NTE1�circuit
LTE1�rack�shelf�lt_slot�circuit
The E3�NT units (NTA and NTB) support corresponding E3
facilities.The AIDs for the NT E3 facilities are:
{NTE3|NTE3A|NTE3B}
DS1 Facilities
DS3 Facilities
SHDSL Facilities
Voice GatewayFacilities
Appendix D System Access Identifiers
163 / 1663EC 36876 AEAA TCZZA Edition 02
The ASAM supports DS1 facilities on DS1�LT cards.The AID for
these DS1 facilities is:
LTT1�rack�shelf�lt_slot�circuit
Note Only HD LTs are supported. Each supports 8 circuits.
The DS3�NT units (NTA and NTB) support corresponding DS3
facilities. The AIDs for the NT DS3 facilities are:
NT Facilities:
{NTT3|NTT3A|NTT3B}
LT Facilities:
LTT3�rack�shelf�lt_slot�circuit
Note DS3�LT units are only supported for HD and UD
systems in release 4.2.
The A7300 ASAM supports SHDSL LT cards. SHDSL facilities in the
LT card are accessed via the following AIDs:
LTSHDSL�rack�shelf�lt_slot�circuit
(SHDSL facility in the LT)
LTSHDSLDEV�rack�shelf�lt_slot�circuit�unit
(A unit in the SHDSL facility in the LT)
where unit = SHDSL unit in a span (1..2)
unit 1 = STU�C
unit 2 = STU�R
LTSHDSLSEG�rack�shelf�lt_slot�circuit�unit�side
(A segment in the SHDSL facility)
where side = Side of the unit:
N � Network Side
C � Customer Side
LTSHDSLSWP�rack�shelf�lt_slot�circuit�unit�side�wirepair
(A specific wire�pair associated with an SHDSL Segment)
where wirepair = The wire�pair in a segment:
1 � Pair�1 (only pair in a 2�wire mode)
2 � Pair�2 (second pair in a 4�wire mode)
The system supports VALT LT cards. Voice gateway facilities in the
LT card are accessed via AID:
LTVOXPORT�rack�shelf�lt_slot�circuit
ATM Port
ATM Virtual Path Link(VPL)
ATM Virtual ChannelLink (VCL)
IMA Group (IMAGRP)
Appendix D System Access Identifiers
164 / 166 3EC 36876 AEAA TCZZA Edition 02
D.6 Miscellaneous Access Identifiers
This section describes various miscellaneous AIDs.
ATM Ports in the NE are identified by the following AIDs:
NTATM
LTATM�rack�shelf�lt_slot�circuit
LTIMAATM�rack�shelf�lt_slot�imagrp
SERVATM�rack�shelf�serv_slot�circuit
Where:
imagrp is the IMA Group number in the LT
serv_slot is the slot number where the Server card is installed.
The Virtual Path Links in the ATM facilities on the NT and the LT
side are identified by the following AIDs:
NTVPL�vpi
LTVPL�rack�shelf�lt_slot�circuit�vpi
Where vpi is the VPI (Virtual Path Identifier) for the VPL.
The Virtual Channel Links in the ATM facilities on the NT and the
LT side are identified by the following AIDs:
NTVCL�vpi�vci
LTVCL�rack�shelf�lt_slot�vpi�vci
Where vpi is the VPI (Virtual Path Identifier), and vci is the VCI
(Virtual Channel Identifier) for the VCL.
The ASAM supports the use of ATM Forum's Inverse Multiplexing
for ATM (IMA) for E1, DS1 and SHDSL facilities. The AIDs for the
IMA Groups are:
NTIMA (for E1 NT)
LTIMA�rack�shelf�lt_slot�imagrp
Where imagrp is the IMA Group number in the card:
1..4 : SD and HD E1 boards
1..8 : HD and UD DS1 boards
1..24 : HD and UD SHDSL boards.
Signaling Channel(SIGCHN)
Signaling Subsystem(SIGSYS)
SVC User (SVCUSR)
IP�Port (IPPORT)
Environment (ENV)
Appendix D System Access Identifiers
165 / 1663EC 36876 AEAA TCZZA Edition 02
The ASAM system supports SVC capability. The AIDs for accessing
Signaling Channels are:
NTSIGCHN
LTSIGCHN�rack�shelf�lt_slot�circuit
LTIMASIGCHN�rack�shelf�lt_slot�imagrp
The ASAM supports SVC capability. The AID for accessing the
Signaling Subsystem is:
SIGSYS
The ASAM supports SVC capability. The AID for accessing an SVC
User is as follows:
<ATM Address>
The addresses are entered via TL1 in one of the following formats:
Native E.164: E164�ddddddddddddddd (1..15 digits)
AESA DCC: DCC�dddF.xxxxxxxxxxxxxxxxxxxx.xxxxxxxxxxxx.xx
AESA ICD: ICD�dddd.xxxxxxxxxxxxxxxxxxxx.xxxxxxxxxxxx.xx
AESA E.164: AE164�dddddddddddddddF.xxxxxxxx.xxxxxxxxxxxx.xx
Unformatted AESA : A�xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
(2..40 digits)
where:
d = '0' .. '9' (decimal digit)
x = '0' .. 'F' (hexadecimal digit)
F = Optionally specified hexadecimal 'F' digit
The ASAM supports ports for communications via the Internet
Protocol. The following AIDs support ports that can be configured
by the user:
ATM�1 � The first IP�over�ATM port in the NT
NTENET � The IP over Ethernet interface in the NT
The ASAM supports 5 external alarm sensing inputs via the ACU.
These can be customized for any environment alarm. These
environment alarm inputs are identified by:
ENV�<number>
Where <number> is the number of the alarm input from 1..5.
Appendix D System Access Identifiers
166 / 166 3EC 36876 AEAA TCZZA Edition 02
D.7 Generic Group Access Idenfifiers
The ASAM defines some generic AIDs that represent a group
(class) of objects in the NE. These are used in conjunction with
functions that can only be performed on the group or class as a
whole. Example of these functions include changing Alarm
Attributes which are defined for the group. The following generic
group AIDs are supported:
ALL Represents all entities of the type defined by
the command modifier
COM Represents objects that are common or
shared by all entities in the NE
EQPT Represents every equipment in the NE
ADSL Represents every ADSL facility in the NE
OC3 Represents every OC3 facility in the NE
STS3C Represents every STS3C facility in the NE
E1 Represents every E1 facility in the NE
E3 Represents every E3 facility in the NE
T1 Represents every T1/DS1 facility in the NE
T3 Represents every T3/DS3 facility in the NE
SHDSL Represents every SHDSL facility in the NE
IMAGRP Represents every IMA Group entity in the
NE
IMALNK Represents every IMA Link entity in the NE
SIGCHN Represents every signaling channel in the
NE
SIGSYS Represents the Signaling Subsystem in the
NE
IPGW Represents all instances of IP Gateway
server cards