GUIDELINES ON USE OF READY MIXED CONCRETE 3. Effect of transit time on Ready Mixed Concrete: 3.1 Loss of workability: 3.1.1 It is alw ays emphasized t hat concrete should be laid in the position w ithout any loss of time to avoid reduction in workability and setting & stiffening of concrete. This aspect becomes very critical in case of Rea dy Mixed Concrete where the time interval in between mixing and placing of concrete is considerable. As concrete stiffe ns w ith passage of time, delay in placement of concrete reduces workability of concrete. In addition, af ter sometime setting of concrete m ay also ta ke place. This is due to continued hy dration reaction of cement, evaporation of mixed water and absorption of mixed water by the aggregates. Typical relat ionship in between loss of w orkability and transit tim e is given in figure-1. This figure should be taken as indicative only, because the actua l result will depen d upon the constituent material, mixed proportion, ambient temperature, humidity and method of transport etc. Reduction in w orkability m ay lead to difficulty in placement of concrete. Thus, w hile planning for use of Ready Mixed Concrete, the aspect of loss of workability in the likely transit time involved should be taken into account. By measuring slump/ compacting factor immediately after mixing at RMC plant & after a lapse of predetermined time (i.e. anticipated transit time), loss of workability may be estim ated. Desired w orkability at the t ime of delivery should be clearly specified in tender conditions. 3.1.2 In order to reduce rate of loss of workability generally w ater reducing agent / superplasticizer is used. Use of water reducing agent/ adm ixtures should be permitted after test ing their suitability in proposed concrete mix. Dose of water reducing agent/ super plasticiser should be decided on trials. Excessive dose may lead to segregat ion. In addition, there m ay be retardation also. 3.1.3 IS: 4926-1976 which is currently under revision, permits retempering i.e. addition of water in concrete at s ite to restore the workability, provided requirement for uniformity, as specified in IS: 4926-1976, are met with. Uniformity requirement specify variation limits for properties like air content, slump, compressive strength & density etc. At site, there is no way to j udge whether specified uniformity requirement are met or not. Moreover, addition of water affects the strength and durability characteristic of concrete. Thus, it is advised that retempering i.e. addition of water after mixing, should not be permitted at all either during transit or at the site of construction.

Upload: aris-tesoro

Post on 18-Oct-2015

24 views

Category:

Documents


0 download

DESCRIPTION

Concrete

TRANSCRIPT

  • GUIDELINES ON USE OF READY MIXED CONCRETE 3. Effect of transit time on Ready Mixed Concrete: 3.1 Loss of workability: 3.1.1 It is always emphasized that concrete should be laid in the position without

    any loss of time to avoid reduction in workability and setting & stiffening of concrete. This aspect becomes very critical in case of Ready Mixed Concrete where the time interval in between mixing and placing of concrete is considerable. As concrete stiffens with passage of time, delay in placement of concrete reduces workability of concrete. In addition, after sometime setting of concrete may also take place. This is due to continued hydration reaction of cement, evaporation of mixed water and absorption of mixed water by the aggregates. Typical relationship in between loss of workability and transit time is given in figure-1. This figure should be taken as indicative only, because the actual result will depend upon the constituent material, mixed proportion, ambient temperature, humidity and method of transport etc. Reduction in workability may lead to difficulty in placement of concrete. Thus, while planning for use of Ready Mixed Concrete, the aspect of loss of workability in the likely transit time involved should be taken into account. By measuring slump/ compacting factor immediately after mixing at RMC plant & after a lapse of predetermined time (i.e. anticipated transit time), loss of workability may be estimated. Desired workability at the time of delivery should be clearly specified in tender conditions.

    3.1.2 In order to reduce rate of loss of workability generally water reducing

    agent / superplasticizer is used. Use of water reducing agent/ admixtures should be permitted after testing their suitability in proposed concrete mix. Dose of water reducing agent/ super plasticiser should be decided on trials. Excessive dose may lead to segregation. In addition, there may be retardation also.

    3.1.3 IS: 4926-1976 which is currently under revision, permits retempering i.e.

    addition of water in concrete at site to restore the workability, provided requirement for uniformity, as specified in IS: 4926-1976, are met with. Uniformity requirement specify variation limits for properties like air content, slump, compressive strength & density etc. At site, there is no way to judge whether specified uniformity requirement are met or not. Moreover, addition of water affects the strength and durability characteristic of concrete. Thus, it is advised that retempering i.e. addition of water after mixing, should not be permitted at all either during transit or at the site of construction.

  • GUIDELINES ON USE OF READY MIXED CONCRETE

  • GUIDELINES ON USE OF READY MIXED CONCRETE 3.2 Setting of concrete: 3.2.1 Excessive delay in transportation of concrete may lead to initial setting of

    concrete and may render it unusable. In order to avoid setting of concrete, generally retarder i.e. retarding admixture is used which prolong the setting of concrete. While permitting use of retarder, it should be ensured that the suitability and dose of retarder is decided after conducting necessary trials. It may be noted that generally retarding effect of retarder is smaller at higher temperature and sometimes few retarders seem to be in-effective at extremely high temperature. Thus, it is desirable to keep the temperature of concrete as low as possible. Influence of temperature on retardation of initial setting time of concrete as mentioned under Chapter V of the book Properties of Concrete by A.M. Neville is furnished in Table-2. The values furnished in Table-2 are based on Lab. results obtained under specific condition and can not be generalised for use.

    Table-2:

    Influence of the temperature on retardation in initial setting time.

    ASTM C 494-92 Type

    Nature of Admixture Retardation in initial setting time (h:min) at temperature of:

    30o C (86 o F)

    40o C (104 o F)

    50 o C (122 o F)

    D Sodium salt of hydroxylic acid

    4:57 1:15 1:10

    D Lignin based calcium salt 2:20 0:42 0:53 D Calcium-lignosulfonate

    based 3:37 1:07 1:25

    B Phosphate-based - 2:20 2:30 3.2.2 In view of above, it is necessary that suitability of retarding admixture is

    judged at the maximum ambient temperature likely to be achieved during concreting. In addition, it is also important that a dose of retarding admixture is tested by conducting trials. Large quantity of admixture/ retarder may delay the setting of concrete adversely or may prevent the setting of concrete totally. Some time dosing of admixture is done in stages to ensure desired workability. In such cases, admixture should be mixed at delivery site only. Addition of admixture should not be permitted during transit.

  • GUIDELINES ON USE OF READY MIXED CONCRETE 3.2.3 Curing:- Use of retarders also may increase the risk of plastic shrinkage.

    Good curing, soon after finished concrete surface shows sign of initial set, will reduce plastic shrinkage cracks. Protecting the concrete surface against hot and windy condition by covering the surface with wet hessain cloth also reduces shrinkage. Usually, Ready Mixed Concrete needs fast curing than normal concrete. The starting time of curing should be carefully decided and proper curing started once the concrete shows sign of initial set.

    3.3 Time period for delivery of concrete: In order to control loss of workability and setting of concrete, IS: 4926, Cl.

    6.3.1 specifies that concrete should be delivered completely to the site of work within one and half hours ( when the atmospheric temperature is above 20o C) and within two hours ( when the atmospheric temperature is at or below 20o C) of adding the mixing water to the dry mix of cement and aggregate or adding the cement to the aggregate which ever is earlier. Adequacy of the time period, required for delivery of concrete, should be checked. In case, location of site of construction is such that this time period is inadequate, delivery time period should be increased and specified clearly duly keeping some margin for hurdles in the way (i.e. level crossing/ check post/ heavy traffic congestion locations etc).

    3.4 Checking suitability of admixture: As explained earlier, generally admixture like water reducing agents/

    retarders are used in Ready Mixed Concrete for retention of workability and to avoid setting of concrete. IS: 9103 Specification for admixtures for Concrete may be referred to judge the suitability of admixtures. According to it, the concrete mix should be prepared both with and without admixture using the same raw materials as proposed to be used for the work. The later being treated as the reference or controlled concrete mix. Test samples from both the mixes should be prepared and tested for physical requirements as laid down under Table-3. The properties of the concrete mix with admixture should conform to the requirements specified under Table-3.